Search Results

Search found 5131 results on 206 pages for 'iis newb'.

Page 112/206 | < Previous Page | 108 109 110 111 112 113 114 115 116 117 118 119  | Next Page >

  • How do I monitor IIS7 output caching?

    - by foosnazzy
    I have dynamic content that I've configured output caching upon. Based on my tests it doesn't seem like IIS is seeing the content as cache-worthy. How can I monitor what IIS is doing? It appears as though PerfMon has some counters I'm interested in, but I'm not sure which ones to look at. If my content is not querystring or form parameter based, but URI based will my content not be deemed cache-worthy?

    Read the article

  • Windows 2003/IIS6 - Unexpected Error: C0000005

    - by Chirans
    Our event logs are full of these errors Unexpected error. A trappable error (C0000005) occurred in an external object. The script cannot continue running. We have tried in various ways but could not stop this error. After continuous errors, the IIS hangs up. We are also getting another error, Warning: IIS log failed to write entry. Please help me with the solution.

    Read the article

  • Zend Server Cannot restart PHP: permission denied for user

    - by user30115
    When I click "Restart PHP" in Zend Server web interface, I get this error in the logs: PHP Warning: Cannot restart PHP: permission denied for user IIS APPPOOL\DefaultAppPool. in C:\Program Files (x86)\Zend\ZendServer\GUI\application\CE\models\ZwasComponents\Util\Api\UserServer.php on line 86 Based on http://kb.zend.com/index.php?View=entry&EntryID=426 I tried to give permissions to user IIS APPPOOL\DefaultAppPool to the folder C:\Program Files (x86)\Zend\ZendServer\, however it still gives the same error. Do you know to what resources the application pool does not have permissions to?

    Read the article

  • Can I enable gzip/deflate in IIS6 without restart?

    - by nibblebot
    I have gone through the steps of enabling static compression for my IIS 6.0 site: enable it in IIS Manager enable edit-while-running add the extensions i need to compress directly to the metabase: js, css wait for the metabase.xml to update to the latest major history version It is still not compressing JS and CSS. Is there anyway to enable this without iisreset?

    Read the article

  • Attach BCC to all emails processed through Windows Server 2008 SMTP relay

    - by Grant H.
    I currently have a relatively complicated application that sends emails via a nightly job through an SMTP server on Windows Server 2008. Is there a way to configure IIS/SMTP to send a copy of every email that's relayed to another email address? Essentially, can I add a BCC on the fly through IIS/SMTP configuration? Because of the complexity of the application, we would prefer to change the behavior this way if it's possible as opposed to making code changes to the application.

    Read the article

  • I enabled ISS on Windows 7 but it's not working

    - by John
    I followed Windows instructions, and turned on several parts of IIS. But http://localhost isn't working, and I don't see the IIS entry in Administrative Tools either. I only want to use SSI, not ASP(.net) or FTP. What should I check and why isn't it working? It didn't ask me to restart Windows, is that required?

    Read the article

  • Win server 2008 change port of RD Gateway

    - by Mel
    Is it possible to change the port used by RD Gateway. I know its integrated with IIS and it uses port 443 (SSL) so i've changed my IIS bindings to use a different port for SSL communications. however, I can't find any way to specify the RD gateway port in the RD client. Has anyone ever done this before? Reason I'm asking is, my ISP just recently blocked port 80 and 443 so I am forced to use another port.

    Read the article

  • Enable FTP Publishing on IIS7?

    - by David Lively
    I've followed the steps in http://learn.iis.net/page.aspx/303/adding-ftp-to-a-web-site/ However, when I get to the part where it says to click "add ftp publishing to website", the option is not visible in the IIS management console. I've verified that the "FTP Publishing Service" is installed in the server manager, and I can see it running in the services applet and via netstat -a. Suggestions?

    Read the article

  • PHP and MySQL on IIS7: can't find php_mcrypt.dll in php.ini

    - by user46250
    I have installed PHP with Microsoft Web PI. Then I installed mysql. According to http://learn.iis.net/page.aspx/353/install-and-configure-mysql-for-php-applications-on-iis-7/ I have to Uncomment the following lines by removing the semicolon: extension=php_mysqli.dll extension=php_mbstring.dll extension=php_mcrypt.dll But there is no extension=php_mcrypt.dll in php.ini installed by web PI so should I add it by hand then where ? and where should I check that php_mcrypt.dll exists ? Seems nobody knows, should better ask on Microsoft forum ?

    Read the article

  • How can I do a "Coming Soon" redirect on IIS6 for everyone except a couple specific IPs?

    - by colinodell
    We're about to do some major maintanence on an IIS 6 / ASP (Classic) website. We want all visitors to be redirected to a "Coming Soon" page (or something similar). This should NOT apply to our dev team (operating remotely), so we'd want to specify certain IPs that should have access to the under-construction site. How can this be accomplished in IIS 6? (Using classic ASP if needed)

    Read the article

  • What about Windows 7 as a web server?

    - by Magnetic_dud
    We have to replace our server (2003-based), and we was thinking that it's time to switch to Windows 2008 r2. Then i saw this: http://technet.microsoft.com/en-us/library/cc753473.aspx We only need IIS, no ftp/email/AD required It looks like IIS in Win7 and Win2008r2 it's almost the same. How do you think about Windows 7 as a web server? There are some "hidden" limitations? We could even save a lot of money.

    Read the article

  • The directory or file specified does not exist on the Web server.

    - by Guy
    I have a hybrid asp.net web forms / mvc application that I recently converted to .net 4 with mvc2. I have set-up that application to run on IIS 7.5 (on Windows 7) and the web forms part of the site is running okay but the MVC part is not. Whenever I try and access a page that needs to go through the routing engine I get HTTP Error 404.0 - Not Found The resource you are looking for has been removed, had its name changed, or is temporarily unavailable. Module IIS Web Core Notification MapRequestHandler Handler StaticFile Error Code 0x80070002 I'm debugging this web site through VS2010 (so I've set-it-up to use IIS instead of Cassini) and when I put a break point in the Application_Start function it is never hit so the routes are never registered. When I put a break point in the Page_Load function in one of the aspx page code-behinds it gets hit. So it seems that the problem is that the route is not being registered. What am I missing?

    Read the article

  • GD DLL installation

    - by smokinguns
    I'm using the JpGraph library(PHP graphing Lib). I'm getting the foll error: "JpGraph Error Your PHP installation does not seem to have the required GD 2.x library enabled. Please see the PHP documentation, "Image" section. Make sure that "php_gd2.dll" statement is uncomment in the [modules] section in the php.ini file" I uncommented the php_gd2.dll statement in php.ini(in C:\WINDOWS) and set the 'extension_dir' as extension_dir = C:\PHP\extensions (I have a extensions directory and put the php_gd2.dll in this directory ). I restarted IIS and when I fire up my webapp, it doesnt comeup. I commented out the php_gd2.dll and restarted IIS again. The webapp came up. I dont understand what I'm doing wrong. Here is the server config: Windows Server 2003, with IIS Version 6. The PHP version is 4.3.8

    Read the article

  • Linq to SQl over WCF Timesout after several calls

    - by Redeemed1
    I have a L2S Repository class which instantiates the L2S DataContext in its constructor. The repository is instantiated at run time (using Unity) in a service hosted in IIS with WCF. When I run up the client MVC applicaton the calls to the backend WCF service work for a while and then timeout. I suspected perhaps a database issue as I was depending on IIS garbage collection to dispose of unused DataContext instances in the IIS host but when I checked the characteristics of the problem I notice the following: The client makes the call to WCF but the WCF service does not respond. Next, the client times out Some time later (several minutes) the service actually executes the request by instantiating the repository and servicing the call. I have checked both client and server traces logs and only the client shows WCF errors (the timeout error). Where should I look? Is it something in WCF or is L2S possibly blocking with unfreed conenctions, resources etc.? Many thanks Brian

    Read the article

  • Visual Studio 2008 built-in web server needs integrated pipeline mode - How?

    - by jdk
    Using Visual Studio 2008 and built-in web server. In a Web Handler .ashx file public void ProcessRequest(HttpContext context) { context.Response.ContentType = MimeType_text_xvcard; context.Response.Headers.Add(HttpHeader_ContentLength, "2138"); when I try to add an HTTP header I get the exception: This operation requires IIS integrated pipeline mode. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.PlatformNotSupportedException: This operation requires IIS integrated pipeline mode. I can find information about this error on the Internet but need specific info about how to presumably enable Integrated Pipeline mode (through web.config?) to allow HTTP headers to be manipulated. How do do I put the built-in web server into integrated pipeline mode? Note: Not using full-fledged IIS

    Read the article

  • Query Cache Issues - releasing cache locks?

    - by Corey Coogan
    I have enabled query caching to use the NHibernate.Caches.Prevalence.PrevalenceCacheProvider provider. This is running on IIS 7, WCF service. I have limited rights to what I can do, but I'm getting an exception about releasing cache locks. I've created the following 2 directories in the system32/inetsrv directory and given full control to the account IIS is using. NHibernate.Cache.StandardQueryCache Some other cache dir I can think of right now This doesn't happen in my local environment so I'm thinking this is somehow related to caching. Do I need to give the IIS account full control to the inetsrv dir as well?

    Read the article

  • Visual Studio 2008 built-in web server raises integrated pipeline error on Http Header manipulation

    - by jdk
    Using Visual Studio 2008, built-in web server. In a Web Handler .ashx file public void ProcessRequest(HttpContext context) { context.Response.ContentType = MimeType_text_xvcard; context.Response.Headers.Add(HttpHeader_ContentLength, "2138"); when I try to added a header I get the exception This operation requires IIS integrated pipeline mode. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.PlatformNotSupportedException: This operation requires IIS integrated pipeline mode. I can find information about this on the Internet but need specific info about how to work with Integrated Pipeline mode (presumably through web.config?) to allow HTTP headers to be manipulated. Note: I am using the Visual Studio built-in web server instead of full-fledged IIS

    Read the article

  • Coldfusion 9 installation problem with IIS7

    - by Saul
    Windows web server 2008 R2 64 bit, CF9 64 bit, IIS7, ISAPI extensions and filters and II6 metabase compatability installed. OS is on C default, and trying to install CF to D: Testing IIS and it shows index.html correctly from c:\inetpub\wwwroot at http://localhost/index.html Then I install CF to D:\ , single standard server licence, select run with all IIS sites, select C:\inetpub\wwwroot as the web root for administrator, and when it gets to the bit where it is supposed to open up administrator to complete the installation it opens up the browser with a 500 error. Now when I go back to http://localhost/index.html I also get a 500 error, if i uninstall CF I can again reach the html page. CFIDE has been installed in C:\inetpub\wwwroot presumably correctly. Can anyone tell me where I'm going wrong please. Update The exact IIS error is HTTP Error 500.0 - Internal Server Error The page cannot be displayed because an internal server error has occurred. Module IsapiModule Notification ExecuteRequestHandler Handler AboMapperCustom-28262 Error Code 0x800700c1 Requested URL http://127.0.0.1:80/test.htm Physical Path C:\inetpub\wwwroot\test.htm Logon Method Anonymous Logon User Anonymous

    Read the article

  • debugging error -- error attaching to w3wp.exe

    - by George2
    Hello everyone, I am using VSTS 2008 + .Net 3.5 + C#. And I developed a custom Forms authentication module for IIS 7.0 and I attach to w3wp.exe to debug this module. During the attach process (I just select Tools - Attach to Process, no further operation performed on the computer I am debugging -- I just wait for the attach to be completed), I met with the following error, any ideas what is wrong? The web server process that was being debugged has been terminated by Internet Information Services (IIS). This can be avoided by configuring Application Pool ping settings in IIS. See help for further details. thanks in advance, George

    Read the article

  • Setup Project is not correctly registering assembly in GAC

    - by Arnold Zokas
    I have created a custom Rewrite Provider for IIS 7 following instructions in this article: Developing a Custom Rewrite Provider for URL Rewrite Module To simplify deployment, I have created a VS2010 Setup Project and configured it to deploy my assembly to GAC. When I run the installer, it completes successfully, and appears to be registered the assembly in GAC (I have verified using gacutil.exe /l). However, when I go to IIS Manager to register the new rewrite provider it is not displayed in the list of available providers. I have also tried to install the assembly manually using gacutil.exe /if. This does work and makes assembly visible in the list of available providers in IIS Manager. Am I missing some sort of configuration in my Setup Project?

    Read the article

  • Impersonation in asp.net, confused about implmentation when used with Active Directory & Sql Server

    - by AWC
    I have an internal website that is using integrated windows authentication and this website uses sql server & active directory queries via the System.Directory.Services namespace. To use the System.Directory.Services namespace in ASP.NET I have to run IIS under an account that has the correct privileges and importantly have impersonation set to true in the web config. If this is done then when I make a query against AD then the credentials of the wroker process (IIS) are used instead of the ASPNET account and therefore the queries will now succeed. Now if I am also using Sql Server with a connection string configured for integrated security ('Integrated Security=SSPI') then this interprets the ASP.NET impersonation to mean that I want to access the database as the windows credentials of the request no the worker process. I hope I'm wrong and that I've got the config wrong, but I don't think I have and this seems not to be inconsistent? It should be noted I'm using IIS 5.1 for development and obivously this doesn't have the concept of app-pools which I believe would resolve the problem.

    Read the article

  • Cross Domain Post - Losing POST Data

    - by Tomas Beblar
    I have 2 servers, both running R2 / IIS7 / ASP Classic sites (can't get around any of that) Server A is making the follow calls: Dim objXMLHTTP, xml Set xml = Server.CreateObject("Msxml2.ServerXmlHTTP.6.0") xml.Open "POST", templateName, false xml.setRequestHeader "Content-Type", "application/xml" xml.Send variables Where the templateName is the URL of Server B (It's an email template) ... and variables are a name value pair string like a query string password=myPassword&customerEmail=Dear+Bob,.... Server B receives the POST but all the POST data (password=myPassword&customerEmail=Dear+Bob,....) is missing from the POST password = Request.Form("templatePassword") customerEmail = Request.Form("RackAttackCustomerEmail") The above values are all empty. Here's the kicker. This all worked on our old servers (Windows Server 2003, IIS 6) But when we migrated over, this stopped working correctly. My question is: What would cause the POST data to be dropped in IIS 7 when it all worked in IIS 6? I've done about 3 days of research into this trying many different things and nothing has worked. The POST data is just gone.

    Read the article

  • IIS7 Modules - managed or native?

    - by Simon Linder
    Hi all, as the old ISAPI filters are going to die sooner or later, I want to rewrite an old ISAPI filter that was used in IIS 6 into a module for use in IIS 7. The module will be used globally, meaning it will be used within each site, on a Windows Server 2008 R2 with IIS 7.5 installed, that will host several thousand web sites and managing about 50 application pools. My question now is if I should write that module in managed or unmanaged code? One of my concerns regarding managed code is the massive memory consumption due to the .NET framework overhead. I don't know how this would effect the server's performance. I already wrote modules in managed as well as in unmanaged code. So this is not the bothering my decision. But I would prefer to write the module in C# if there are no huge drawbacks. Any suggestions about that issue?

    Read the article

  • How do I get meaningful error messages in IIS7?

    - by Petras
    I have a classic ASP website that is crashing in IIS7. It is crashing because IIS doesn't allow file uploads greater than a certain size. I know this because files below about 200k work fine. I removed the Status Code 500 error in IIS but I still don't get a file name and the line where my code failed as I do when running locally. Instead I get: "The page cannot be displayed because an internal server error has occurred. If you are the system administrator please click here to find out more about this error." How do I get a file name and the line where my code failed? Here are my IIS settings:

    Read the article

< Previous Page | 108 109 110 111 112 113 114 115 116 117 118 119  | Next Page >