  • chown: changing ownership of `.': Invalid argument

    - by Pierre
    I'm trying to install some new files on our new server while our sysadmin is in holidays: Here is my df # df -h Filesystem Size Used Avail Use% Mounted on /dev/sdb3 273G 11G 248G 5% / tmpfs 48G 260K 48G 1% /dev/shm /dev/sdb1 485M 187M 273M 41% /boot xxx.xx.xxx.xxx:/commun 63T 2.2T 61T 4% /commun as root , I can create a new directory and run chown under /home/lindenb # cd /home/lindenb/ # mkdir X # chown lindenb X but I cannot run the same command under /commun # cd /commun/data/users/lindenb/ # mkdir X # chown lindenb X chown: changing ownership of `X': Invalid argument why ? how can I fix this ? updated: mount: /dev/sdb3 on / type ext4 (rw) proc on /proc type proc (rw) sysfs on /sys type sysfs (rw) devpts on /dev/pts type devpts (rw,gid=5,mode=620) tmpfs on /dev/shm type tmpfs (rw) /dev/sdb1 on /boot type ext4 (rw) none on /proc/sys/fs/binfmt_misc type binfmt_misc (rw) sunrpc on /var/lib/nfs/rpc_pipefs type rpc_pipefs (rw) xxx.xx.xxx.xxx:/commun on /commun type nfs (rw,noatime,noac,hard,intr,vers=4,addr=xxx.xx.xxx.xxx,clientaddr=xxx.xx.xxx.xxx) version: $ cat /etc/redhat-release CentOS release 6.3 (Final)

    Read the article

  • Driver choice for addressing ubuntu wireless card issues

    - by Holly
    Hello, this should be a relatively simple question. I'm attempting to get my windows wireless card to work with ubuntu, booted from my portable hard drive. This is the guide I'm attempting to follow is on help.ubuntu.com, /community/WifiDocs/Driver/Ndiswrapper My wireless card is a Broadcom Corporation BCM4318 AirForce One 54g 802.11g Wireless LAN Controller. My computer is an HP Pavilion Entertainment dv5 notebook, which came with Vista 64. I would like confirmation about which of the drivers I should use. At this point, I'm leaning towards Broadcom BCM4318 HP Pavilion zv6000, but I thought it best to ask advice before taking action. The drivers I have to chose from are listed on this page http://sourceforge.net/apps/mediawiki/ndiswrapper/index.php?title=Category:Broadcom Thanks! Holly

    Read the article

  • Oracle licensing /pricing ?

    - by Quandary
    Question: I'd like to download Oracle 11g database for evaluation purposes. Now I found this link for downloads: http://www.oracle.com/technetwork/database/enterprise-edition/downloads/index.html But it says one must register 'for accessing premium contents'. But in the same time, it looks like one can download the full database for free. But surely, Oracle doesn't give it for free, but in the registration, there's no mention of any cost/fees, or any billing address. Is this registration free, or as 'premium' suggests, will you get a bill for it if you do (supposed you enter true data) ? Or how does Oracle handle licensing/payment ? I can not see any price tag there anywhere, nor any information on it on that registration page.

    Read the article

  • Why can't I grant exec on dbms_lock.sleep() OR create a procedure using it (but I can run it fine on its own)

    - by Richard Green
    I am trying to write a small bit of PL/SQL that has a non-CPU burning sleep in it. The following works in sqldeveloper begin dbms_lock.sleep(5); end; BUT (as the same user), I can't do the following: create or replace procedure sleep(seconds in number) is begin dbms_lock.sleep(seconds); end; without the error "identifer "DBMS_LOCK" must be declared... Funny as I could run it without a procedure. Just as strange, when I log in as a DBA, I can run the command grant exec on dbms_lock to public; and I get ERROR at line 1: ORA-00990: missing or invalid privilege This is oracle version "Oracle Database 11g Express Edition Release 11.2.0.2.0 - 64bit Production"

    Read the article

  • iPod Touch G4 disconnects from Belkin N+ Router at random intervals

    - by leeand00
    I have an iPod Touch G4 and a Belkin N+ Router F5D8235-4 v2, and for some reason the iPod Touch disconnects from the router at random intervals. Checking the settings in the iPod, it will read that it is still connected to the router, but before I can access the internet again, I have to turn on Airplane mode and then turn it off again to get any program to work with the Internet again. I've tried upgrading the firmware in the router, but that also doesn't seem to help. I'm using the wiresless mode 802.11b&802.11g&802.11n in the 20/40MHz frequency. Is there any way of fixing this issue? It doesn't happen with any of the other devices that are connected to the router. This post has been cross-posted here

    Read the article

  • ORA-1034 Oracle Not Found

    - by Venkata
    I have recently installed oracle 11g on Windows 7 Home Premium Operating System. I logged in as administrator into windows. I am trying to create a database using DBCA wizard. I started the wizard as administrator. Everything goes fine until last step. However when creating the database the creation fails with ORA-01034 Oracle Not Available error. All my oracle services looks up and running. I consulted the documentation and forums. I have got no clue why I am running into the error.

    Read the article

  • Oracle RAC interconnect in a Dell M1000e Blade Enclosure

    - by Antitribu
    We are looking at a Dell M1000e enclosure and appropriate Blades with 4 NICs each. We are planning on running Linux/Oracle 11g RAC on two blades, storage will be handled on an iSCSI SAN for which two NICs (via passthrough) will be connected leaving us with two NICs (via blade centre switches). We would like to have an interconnect (obviously) , an external IP and an internal IP. Would best practice be to: bond the remaining two interfaces and VLAN as appropriate to provide three virtual interfaces? run the interconnect on one interface and VLAN the external/internal interfaces? purchase a blade with more NICs as the above is a terrible idea? Another option? Please feel free to point out the blindingly obvious or to relevant documentation on support.oracle. I am specifically interested in supported configurations and best practices. Thanks!

    Read the article

  • Router's ssid changes from infrastructure to ad-hoc

    - by waldo
    For a period of time the router's ssid is shown (on various computers) as a normal infrastructure network - computers connect fine and everything works however after a few minutes / hours all computers see the same ssid as an ad-hoc network (not infrastructure). At this point a computer that was already connected continues to work - a computer that isn't cannot connect. Rebooting the router temporarily restores the visibility of the correct infrastructure ssid. Is something interfering? Connecting computers: macbook (2009), iphone 3g, windows vista desktop, windows xp desktop. Details: - D-Link DSL-2740B router set to WPA2-PSK (Personal) - Enable Wireless : Yes - Wireless Network Name (SSID) : ###### - Country : Australia - Wireless Channel : 1 - 802.11 Mode : Mixed 802.11n, 802.11g and 802.11b - Channel Width : Auto 20/40 MHz - Transmission Rate : Best (automatic) - Hide Wireless Network : No - Group Key Update Interval : 0 (seconds)

    Read the article

  • 802.11 Capture Frame

    - by ALi
    I am using wireshark in monitor mode to capture all the frame. I buffered all the QosData in order to calculate the biterate of each station on the network. I calculate the biterate but it is not an accurate value. what i need to know is when the station use the network alone and when it uses it with another station? i know if two station with different wifi card for exemple ( st1 802.11g 54 Mb/s, st2 802.11n 300 Mb/s) if st1 uses alone the line the biterate used is 28 MB/s and if st2 uses alone the network the bit rate increase to approximately 150Mb/s but if the two station use the network at the same time the st1 lost about 80% of its bit rate because of the st1 wifi card thx in advance

    Read the article

  • Connecting two pcs through cable, at the same time as wireless

    - by Steffen
    I've got 2 pcs setup with WLAN - however when I copy files between the machines it takes forever (obviously, since I run 801.11g). So I thought, why not just connect them directly with a cable (my wireless router is the other end of the house, that's why I don't use cables to that) However how should I configure the LAN connection on each machine, so I can use it for transferring files between them, whilst using my WLAN to access the Internet ? I was thinking about letting one machine be gateway, but then Windows pops up with a lot of warnings (basically it says this won't work when you're using two disjoint networks) And now I'm at a loss as to what to try.

    Read the article

  • Weblogic 10.3 weblogic.jar classpath issues

    - by user63063
    I am upgrading an old WLS8.1 app to 10.3 (11g) My ant build includes only the new weblogic.jar in the compile classpath and the build runs with no issues but when I include weblogic.jar as a libeary in the IDE (Intellij) i see many unresolved imports (for example: weblogic.xml.xpath.DOMXPath) when I check the weblogic.jar I see that the classes are indeed missing from it. compiling with verbose revealed that by including weblogic.jar in the ant classpath, many other jars in the BEA_HOME/modules are loaded to the classpath as well (for example: com.bea.core.xml.weblogic.xpath_1.4.0.0.jar) Can anyone explain what is going on? How can I fix my IDE classpath - do I need to import all the module-jars? Many of the module jars seems like they are there to support old deprecated weblogic 8 APIs (like: weblogic.xml.xpath.DOMXPath) how can I exclude these modules from my ant build? (I want to expose the APIs I need to upgrade) Thanks, NY

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Is there a difference between starting a WebLogic Admin Server through the command-line or through t

    - by lindelof
    I have WebLogic 11g installed on my machine under /srv/wls, and I start Node manager on it with /srv/wls/wlserver_10.3/server/bin/startNodeManager.sh. I create my domain with config.sh, and then I want to start the Admin Server of that domain with Node Manager. So I open a WLST session and do the following: > nmConnect(...) > nmStart('AdminServer') But when I then visit localhost:7001/console, and login, the screen on the browser remains blank and the server logs tell me the server has run out of PermGen space. I don't encounter this problem when starting the Admin Server through the shell script under $DOMAIN/startWebLogic.sh. Then it works fine. Any idea what I am doing wrong? I couldn't find anything in Google nor on the Oracle forums...

    Read the article

  • e2fsck / resize2fs problems

    - by BlakBat
    I've got 6 drives (each 1.5T, all same model and firmware revision) that are part of a RAID5 array. The RAID5 makes a LVM volume group and a logical group. The latter contains only one ext3 partition. I've recently ran: e2fsck -f /dev/vg03/lv01 && resize2fs -M /dev/vg03/lv01 which exited without an error. Now when I try to mount /dev/vg03/lv01 I get: EXT3-fs error (device dm-0): ext3_check_descriptors: Block bitmap for group 30533 not in group (block 1000532368)! EXT3-fs: group descriptors corrupted! How do I get out of this predicament? This is all the info I can currently give you: fdisk -l /dev/sd[cdefgh] shows (correctly) that they are "Linux raid autodetect" but fdisk now shows: fdisk -l /dev/md0 Disk /dev/md0: 7501.5 GB, 7501495664640 bytes ... Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table (instead of a LVM type partition) fdisk -l /dev/vg03/lv01 Disk /dev/vg03/lv01: 7501.5 GB, 7501491732480 bytes ... Disk identifier: 0x00000000 Disk /dev/vg03/lv01 doesn't contain a valid partition table (instead of a ext3 type partition) I've tried: e2fsck -fy /dev/vg03/lv01 e2fsck 1.41.12 (17-May-2010) e2fsck: Group descriptors look bad... trying backup blocks... Block bitmap for group 30533 is not in group. (block 1000532368) Relocate? yes Inode bitmap for group 30533 is not in group. (block 1000532369) Relocate? yes Pass 1: Checking inodes, blocks, and sizes Relocating group 30533's block bitmap to 1000524246... Error allocating 1 contiguous block(s) in block group 30533 for inode bitmap: Could not allocate block in ext2 filesystem e2fsck: aborted Extra information I can give you: cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active (auto-read-only) raid5 sdg1[0] sdh1[5] sdf1[4] sde1[3] sdc1[2] sdd1[1] 7325679360 blocks level 5, 128k chunk, algorithm 2 [6/6] [UUUUUU] bitmap: 1/175 pages [4KB], 4096KB chunk unused devices: Lastly, all smartctl tests (short and extendend) showed no errors on any of the disks. Should I try to resize2fs to grow /dev/vg03/lv01 and redo a e2fsck ? Should I cfdisk /dev/md0 and /dev/vg03/lv01 back to their real types? Thanks in advance for all and any help. 2011-09-20 UPDATE I issued the following commands and was able to remount the partition, but by viewing the size (df) of before and after, it seems that 1Tb of data have gone missing. By checking the MD5SUMS (from an old backup) of some files with the "same" files from the remounted partition, some errors have been detected. Commands issued to remount the partition were: dumpe2fs /dev/vg03/lv01 Block count: 1000491435<br /> Block size: 4096<br /> tune2fs -O ^has_journal /dev/vg03/lv01 resize2fs -p /dev/vg03/lv01 dumpe2fs /dev/vg03/lv01 Block count: 1831418880<br /> Block size: 4096<br /> mount -o ro,noatime /dev/vg03/lv01 /mnt/raid OK... but files have been damaged / gone missing.

    Read the article

  • Determining the required depth and specifications for a server cabinet

    - by Bingu Bingme
    I'm trying to understand the considerations ("why") that go into determining the specifications ("what") for a rackmount server cabinet, in order to determine what sort of rack I should purchase for my home use. Since this is for home use, I won't be following certain best practices (eg. hot/cold aisle, not even air conditioning) and may be willing to sacrifice in various areas in order to reduce cost and footprint - but please advise if there are safety concerns or other considerations to note. The most basic specs for a server cabinet are the dimensions (external width x external depth x usable height). Width: commonly 600mm or 800mm (if the use case requires extra clearance around the sides, such as if there is lots of cabling). In my case and most common cases, I'm going to stick with 600mm. Height: Select a sufficiently tall rack to fit my equipment. But how much may I stuff into it? Eg, if there is a 15U rack, can I really populate it with 15U of servers, or should I leave 1U at top and bottom for air circulation? Depth: Racks commonly have external depth of 600mm (network equipment), 800mm, 1000mm, or even longer. I'm trying to see how to fit into the 800mm depth. With reference to http://www.server-racks.com/rack-mount-depth.html, I'm hoping to have the front and rear posts mounted ~ 28.5" (72cm) apart, which would leave only 8cm for front space and rear space. How much rear space (from rear posts to back of rack) do I really need? I won't use cable management arms, so can I mount a 72cm depth server since the power, KVM, network cables won't take up much depth? My most important equipment are all < 60cm depth (4U chassis) and should comfortably fit within the 800mm cabinet. The rest of the equipment are very old 1U servers that range from 65-72cm depth. I might still want to make further use of them, or I might discard them since they are so old. Even if the 72cm servers cannot be powered on in an 800mm rack, I should be able to use them as 1U shelves. But, what server depth can I expect to be able to operate? Or am I forced to upgrade to 1000mm depth racks in order to use any servers deeper than 60cm? With reference to best practices for HP racks, some other specs and installation considerations: There aren't any minimum recommendations for clearance on the sides of the rack. It is recommended to leave 48" front clearance. The 48" front clearance is based on 32" chassis depth, 13" to extend the rack rails and mate the inner/outer rails, and 3" for movement. If I don't use such rails (eg, use shelves instead), it should be sufficient to leave front clearance of chassis depth + 3". It is recommended to leave 30" rear clearance "to provide space for servicing the rack". I'm planning to back the rack into a corner of the room, and wheel it slightly out when I need to access the rear. If the wheeling plan is ok, I still need to know how much rear clearance is required for air circulation and ventilation purposes. Castor wheels and stabilising feet. Since I'm backing the rack into a corner of the room, I'll only be able to set the stabilising feet on the front corners. Thoughts on safety? The rack that I'm considering has front glass doors with side ventilation slits and fully perforated rear doors. I'm hoping this will be a good balance between temperature and noise (only ventilation slits facing out the front, while the rear is facing the walls). Or is the sound of high-rpm fans going to escape through the front slits anyway and destroy my sanity?

    Read the article

  • Windows - Force Wi-Fi to N mode

    - by Frederick Marcoux
    I bought a month ago the D-Link DWA-160 Xtreme N Dual Band USB Adapter and I wonder about the speed. I have a 60Mbps but the speed is never above 300Kbps when I browse Internet or download something. Even from Microsoft or Apple (the fastest server I found). Now on Windows 8, we can see the Wi-Fi stats in Task Manager, there they are: Notice the red rectangle. The signal is 3/5 and I'm about 5 meters far from my router. An Apple Time-Capsule. Also, the connection type is 802.11g, I want N. I made this config in my Device Properties: Does anyone figured out to force the 802.11n in Windows? (Windows 8 preferably)

    Read the article

  • Symantec Protection Suite and System Recovery 2011 Desktop Edition

    - by rihatum
    I am re-posting this as my previous question was being treated as if I am "Shopping or seeking Product Recommendations" even though I was NOT - BTW they have deleted my comments too which were not offensive in nature. anyway - I have re-phrased some parts of my question and I hope SF Admins "Do Not Modify / Edit" this one - will be most grateful for that. I have a lot of respect for the People who visit this SITE and help others ! Just To clarify : Just to go by SF rules - I am not seeking someone to Design this solution, I am simply seeking real world examples, experiences, technical expert opinions / suggestions, any tips or tricks they may have or any problems they may have faced while doing something similar above with these products. I am also not asking for Capacity Planning for Storage, We have done some research and I am seeking Expert Assurance / Suggestions. We (our company) are planning to deploy Symantec Endpoint Protection and Symantec Desktop Recovery 2011 Desktop Edition to our 3000 - 4000 workstations (Windows7 32 and 64) with a few 100s with Windows XP 32/64 Bit. I have read the implementation guide for SEP and have read tech-notes for Desktop Recovery 2011. Our team have planned to deploy this as follows : 1 x dedicated SQL 2008R2 for Symantec Endpoint Protection (Instead of using the Embedded Database) 1 x Dedicated SQL 2008R2 for Symantec Desktop Recovery 2011 (Instead of using the Embedded Database) 1 x Dedicated W2K8 R2 Box for the SEPM (Symantec Endpoint Protection Manager - Mgmt. APP) 1 x Dedicated W2K8 R2 Box for the Symantec Desktop Recovery 2011 Management Application Agent Deployment : As per Symantec Documentation for both of the above, an agent can be pushed via the Mgmt. Application (provided no firewalls are blocking ports required etc. - we have Windows firewall disabled already). Server Hardware : Per SQL Server : 16GB RAM + SAS DISKS + Dual XEON, RAID-10 for the SQL DB or I can always mount a LUN from our existing Hitachi or EMC SAN. SEPM Server : 16GB RAM + SAS DISKS + DUAL XEON System Recovery MGMT SERVER : 16GB RAM + SAS DISKS + DUAL XEON Above is the initial plan we have for 3000 - 4000 client workstation (Windows) Now my Questions :-) a) If we had these users distributed amongst two sites with AD DC / GC in each site, How would I restrict SEPM and Desktop Mgmt. solution to only check for users in their respective site ? b) At present all users are under one building but we are going to move some dept. to a new location (with dedicated connectivity), How would we control which SEPM / MGMT Server is responsible for which site ? c) We have netbackup in our environment backing up other servers, I am planning to protect these 4 (2 x SQL, 1 x SEPM, 1 x System Recovery Mgmt. Server) via netbackup or I can use System recovery 2011 server edition on all 4 of these boxes as well. (License is not an issue as we have the complete symantec portfolio included in our license). d) Now - Saving Desktop backups - What strategies have you implemented ? Any best practice recommendation for a large user base ? I was thinking to either mount a LUN from our Hitachi SAN on the Symantec Recovery Server itself or backup to the users hard drive locally and then copy it over to a network location ? Suggestions welcome :-) If you have anything to add / correct - that will be really helpful before diving into the actual implementation phase. Will be most grateful with your suggestions, recommendations and corrections with above - Many Thanks !

    Read the article

  • Configure Wireless Network Card

    - by Skizz
    I recently upgraded the wireless network card in my Ubuntu PC from an 802.11g to an 802.11n. Now, it can't see my router. It doesn't appear in the list of networks that is displayed when you click on the NetworkManager icon in Gnome. Other networks are listed and I have connected to them (no password required!). I'm using the Windows driver through ndiswrapper and it can see the card. I tested the card in a Windows PC and everything worked. The router's log doesn't show any messages coming from the wireless card. What have I done wrong? If you need any more information, just leave a comment and I'll get add it to the question.

    Read the article

  • Get the wireless adapter frequency-band mode in Windows 7

    - by Petr
    I have a dual-band 802.11n router operating in both frequency bands with the same SSID. My Windows 7 laptop has a dual-band wireless adapter. Is there a way to find out which frequency band is the one currently used by the client? Also, is there a way to set the preffered band? Thanks. EDIT1: The router is Linksys E4200 (V2) and I essentially want to keep the 2.4GHz band in the mixed-mode so that the legacy 802.11g devices can connect while allocating the 5.0GHz band for 802.11n devices. The laptop's adapter (Intel Centrino Ultimate-N 6300 ANG) can operate in both 802.11n modes. EDIT2: Related topic

    Read the article

  • How to increase signal/range of your Wi-Fi antenna-less repeater/booster over the network?

    - by kenorb
    I've BT Home Hub in the upper flat (2-3 walls behind) and I'm using WPS Wireless-N Wifi Range Router Repeater Extender in my flat where I'm using my laptop. These are antenna-less devices. Are there any life-hack tricks to increase signal/range of my repeater without buying the new more powerful repeater? I've tried already to move my repeater closer to the ceiling or putting the aluminium foil underneath, but it didn't help. Are there any methods, specific plates or materials which can boost the signal? Specification: Model: WN518W2 Frequency range: 2.4-2.4835GHz Wireless transmit power: 14 ~17 dBm (Typical) Wireless Signal Rates With Automatic Fallback: 11n: Up to 300Mbps(dynamic), 11g: Up to 54Mbps(dynamic), 11b: Up to 11Mbps(dynamic) Modulation Technology: DBPSK, DQPSK, CCK, OFDM, 16-QAM, 64-QAM Receiver Sensitivity: 300M: -68dBm@10% PER / 150M: -68dBm@10% PER / 108M: -68dBm@10% PER / 54M: -68dBm@10% PER / 11M: -85dBm@8% PER / 6M: -88dBm@10% PER / 1M: -90dBm@8% PER Product dimensions: 11 * 6 * 7cm

    Read the article

  • Apple Airport Extreme Wireless Card M8881 Connectivity Issue

    - by Carlosfocker
    I bought a Apple Airport Extreme Wireless Card M8881 with the antenna for my old Power Mac G5 1.6 Ghz. The computer is running OS X 10.4. The card works and I can connect to my dlink 802.11g wireless router using WPA2/AES encryption. The problem is that the connection has intermittent connectivity issues. When the issue occurs the signal bars for the connection drop to one or two bars and the performance of the connection suffers greatly. The computer isn't far from the wireless router. I have a laptop at the desk where the mac is and it does not have any issues. I'm not sure what it might be? Updated drivers? Firmware? Let me know if I forgot any important information.

    Read the article

  • Where can I configure wireless to be passed on to the Virtualbox guest?

    - by huahsin68
    I have WinXP install in virtualbox which host in Linux. I have a TP-Link (TP-WN321G) USB wifi adapter and have the driver installed inside WinXP. When I plug-in the wifi adapter, there is an option show "Ralink 802.11g WLAN [0101]" in the virtualbox's USB icon, tick on that option, the Device Manager able to detect the hardware which shows TP-Link, but when look into the properties, it says there is no driver was install. I did try to install Ralink driver but still no luck. Just curious why my wifi adapter is TP-Link, but the option show Ralink? May I know how can I emulate the wireless network inside WindowsXP?

    Read the article

  • How do I get a 300Mbps connection over 802.11n?

    - by Daniel Schaffer
    I just bought a new wireless setup, consisting of a Cisco E2000 router, Edimax 7718un USB adapter for my laptop and an Edimax 7728in PCI adapter for my HTPC (which isn't in a location I can run cat5 to). I have to stay in the 2.4GHz band because I have an iPhone and a Wii that will need to connect. I'm aware that 11g devices will drop speeds for 11n devices, but they aren't connected yet. The fastest connection I've been able to get, with the router within 5 feet of either the laptop or HTPC is 144Mbps. The router has settings for "20MHz" and "Auto (20 MHz or 40Mhz) channel width, which I've set to the "Auto" setting. I haven't been able to find anything similar for either of the Edimax adapters. This is the first I've dealt with 11n, so I'm not even sure what else could be causing a problem. How do I get up to 300Mbps, or at least a fair bit closer?

    Read the article

  • Laptop is super slow on network

    - by Gary
    So on our network we have a bunch of wireless macs and window Operating laptops, we have a network setup with 802.11g,b,n. All the laptops seem fine except one which is only getting speeds of 54Mb. I have changed the encryption from AES to TKIP and reset the connection, i have updated the drivers, tried plugging it into the LAN and still same slow speed. Apparently the laptop with the slow speed is fine on other networks. I don't know what to do, can anyone help me?

    Read the article

  • Is there a way to rsync in batches?

    - by Chris
    I have a huge chunk of data (11G) in a subversion repository that I'm using rsync to migrate to Alfresco, which lucene indexes new files as they hit the file system. I'm using a dav mount as a proxy to allow me to rsync. The issue I'm having is the indexing post-rsync is quite an expensive operation for such a huge chunk of data, so I was wondering whether there's a way I could logically separate the rsync into identically-sized batches (say 500MB each) so I could schedule them in cron. At the moment, I'm traversing the top level folders and taking the smallest ones across first, but once I'm done with those, the much larger sub-directories are going to be quite troublesome. Please let me know if you need any further info. Thanks in advance.

    Read the article