Search Results

Search found 25400 results on 1016 pages for 'enable manual correct'.

Page 114/1016 | < Previous Page | 110 111 112 113 114 115 116 117 118 119 120 121  | Next Page >

  • Automating Form Login

    - by Greg_Gutkin
    Introduction A common task in configuring a web application for proxying in Pagelet Producer is setting up form autologin. PP provides a wizard-like tool for detecting the login form fields, but this is usually only the first step in configuring this feature. If the generated configuration doesn't seem to work, some additional manual modifications will be needed to complete the setup. This article will try to guide you through this process while steering you away from common pitfalls. For the purposes of this article, let's assume the following characteristics about your environment: Web Application Base URL: http://host/app (configured as Resource Source URL in PP) Pagelet Producer Base URL: http://pp/pagelets Form Field Auto-Detection Form Autologin is configured in the PP Admin UI under resource_name/Autologin/Form Login. First, you'll enter the URL to the login form under "Login Form Identification". This will enable the admin wizard to connect to and display the login page. Caution: RedirectsMake sure the entered URL matches what you see in the browser's address bar, when the application login page is displayed. For example, even though you may be able to reach the login page by simply typing http://host/app, the URL you end up on may change to http://host/app/login via browser redirect(s).The second URL is the one you will want to use. Caution: External Login ServersThe login page may actually come from a different server than the application you are trying to proxy. For example, you may notice that the login page URL changes to http://hostB/appB. This is common when external SSO products are involved. There are two ways of dealing with this situation. One is to configure Pagelet Producer to participate in SSO. This approach is out of scope of this article and is discussed in a separate whitepaper (TODO add link). The second approach is to use the autologin feature to provide stored credentials to the SSO login form. Since the login form URL is not an extension of the application base URL (PP resource URL), you will need to add a new PP resource for the SSO server and configure the login form on that resource instead of the original application resource. One side benefit of this additional resource is that it can reused for other applications relying on the same SSO server for login. After entering the login page URL (make sure dropdown says "URL"), click "Automatically Detect Form Fields". This will bring up the web app's login page in a new browser window. Fill it out and submit it as you would normally. If everything goes right, Pagelet Producer will intercept the submitted values and fill out all the needed configuration data in the Admin UI. If the login form window doesn't close or configuration data doesn't get filled in, you may have not entered the login page URL correctly. Review the two cautionary notes above and make any necessary changes. If the form fields got filled automatically, it's time to save the configuration and test it out. If you can access a protected area of the backend application via a proxied PP URL without filling out its login form, then you are pretty much done with login form configuration. The only other step you will need to complete before declaring this aspect of configuration production ready is configuring form field source. You may skip to that section below. Manual Login Form Identification Let's take a closer look at Login Form Identification. This determines how Pagelet Producer recognizes login forms as such. URL The most efficient way of detecting login forms is by looking at the page URL. This method can only be used under the following conditions: Login page URL must be different from the post login application URLs. Login page URL must stay constant regardless of the path it takes to reach the page. For example, reaching the login page by going to the application base URL or to a specific protected URL must result in a redirect to the same login page URL (query string excluded). If only the query string parameters change, just leave out the query string from the configured login page URL. If either of these conditions is not fullfilled, you must switch to the RegEx approach below. RegEx If the login page URL is not uniform enough across all scenarios or is indistinguishable from other page locations, PP can be configured to recognize it by looking at the page markup itself. This is accomplished by changing the dropdown to "RegEx". If regular expressions scare you, take comfort from the fact that in most cases you won't need to enter any special regex characters. Let's look at an example: Say you have a login form that looks like <form id='loginForm' action='login?from=pageA' > <input id='user'> <input id='pass'> </form> Since this form has an id attribute, you can be reasonably sure that this login form can be uniquely identified across the web application by this snippet: "id='loginForm'". (Unless, of course your backend web application contains login forms to other apps). Since no wildcards are needed to find this snippet, you can just enter it as is into the RegEx field - no special regular expression characters needed! If the web developer who created the form wasn't kind enough to provide a unique id, you will need to look for other snippets of the page to uniquely identify it. It could be the action URL, an input field id, or some other markup fragment. You should abstain from using UI text as an identifier it may change in translated versions of the page and prevent the login page logic from working for international users. You may need to turn to regular expression wildcard syntax if no simple matches work. For more information on regular expression, refer to the Resources section. Form Submit Location Now we'll look at the form submit location. If the captured URL contains query string parameters that will likely change from one form submission to the next, you will need to change its type to RegEx. This type will tell Pagelet Producer to parse the login page for the action URL and submit to the value found. The regular expression needs to point at the actual action URL with its first grouping expression. Taking the example form definition above, the form submit location regex would be: action='(.*?)' The parentheses are used to identify the actual action URL, while the rest of the expression provides the context for finding it. Expression .*? is a so-called reluctant wildcard that matches any character excluding the single quote that follows. See Resources section below for further information on regular expressions. Manual Form Field Detection If the Admin UI form field detection wizard fails to populate login form configuration page, you will have to enter the fields by hand. Use a built-in browser developer tool or addon (e.g. Firebug) to inspect the form element and its children input elements. For each input element (including hidden elements), create an entry under Form Fields. Change its Source according to the next section. Form Field Source Change the source of any of the fields not exposed to the users of the login form (i.e. hidden fields) to "Generated". This means Pagelet Producer will just use the values returned by the web app rather than supplying values it stored. For fields that contain sensitive data or vary from user to user (e.g. username & password), change the source to User (Credential) Vault. Logging Support To help you troubleshoot you autologin configuration, PP provides some useful logging support. To turn on detailed logging for the autologin feature, navigate to Settings in Admin UI. Under Logging, change the log level for AutoLogin to Finest. Known Limitations Autologin feature may not work as expected if login form fields (not just the values, but the DOM elements themselves) are generated dynamically by client side JavaScript. Resources RegEx RegEx Reference from Java RegEx Test Tool

    Read the article

  • Lenovo Thinkpad L430 overheating due to fan problems

    - by Dirk B.
    This is the same question as Fan not working on thinkpad L430, laptop overheating, but that question has been marked as a duplicate, which it is not, and I cannot reopen it. I'm having problems controlling the fan of my Lenovo Thinkpad L430. The fan doesn't start. Without any fan control installed the fan just doesn't run. If I run stress, it does run a little, but it's nowhere near the speed it should be. After a while, the laptop just overheats and stops. I Tried to install tp-fancontrol, and enabled thinkpad_acpi fancontrol=1, but to no avail. If I try to set the fan speed manually, it doesn't start up. In windows, there's a program called TPFanControl. It turns out that this laptop uses a different scheme to control the fan than other thinkpads. The level runs from 0 to 255, and max = 0 and min=255. Now I'm looking for a fan control program that works for linux. Does anyone know if it actually exists? Anyone with any experience on fan control on a L430? Update: sudo pwmconfig gives the following output: # pwmconfig revision 5857 (2010-08-22) This program will search your sensors for pulse width modulation (pwm) controls, and test each one to see if it controls a fan on your motherboard. Note that many motherboards do not have pwm circuitry installed, even if your sensor chip supports pwm. We will attempt to briefly stop each fan using the pwm controls. The program will attempt to restore each fan to full speed after testing. However, it is ** very important ** that you physically verify that the fans have been to full speed after the program has completed. Found the following devices: hwmon0 is acpitz hwmon1/device is coretemp hwmon2/device is thinkpad Found the following PWM controls: hwmon2/device/pwm1 hwmon2/device/pwm1 is currently setup for automatic speed control. In general, automatic mode is preferred over manual mode, as it is more efficient and it reacts faster. Are you sure that you want to setup this output for manual control? (n) y Giving the fans some time to reach full speed... Found the following fan sensors: hwmon2/device/fan1_input current speed: 0 ... skipping! There are no working fan sensors, all readings are 0. Make sure you have a 3-wire fan connected. You may also need to increase the fan divisors. See doc/fan-divisors for more information. update: If you need it, lspci is available here

    Read the article

  • Reinventing the Wheel – Automating Data Consistency Checks with Powershell

    - by Jonathan Kehayias
    When I started in my current position at the beginning of the year, one of the first things that I did was to schedule a sit down with the various teams of Analysts that exist in our organization to find out more about their systems.  One thing I am always interested in is the manual processes that people do routinely that might be able to be automated.   A couple of the analyst mentioned that they routinely run queries in their systems to identify issues so that they can proactively...(read more)

    Read the article

  • Oracle Solaris Cluster 4.2 Event and its SNMP Interface

    - by user12609115
    Background The cluster event SNMP interface was first introduced in Oracle Solaris Cluster 3.2 release. The details of the SNMP interface are described in the Oracle Solaris Cluster System Administration Guide and the Cluster 3.2 SNMP blog. Prior to the Oracle Solaris Cluster 4.2 release, when the event SNMP interface was enabled, it would take effect on WARNING or higher severity events. The events with WARNING or higher severity are usually for the status change of a cluster component from ONLINE to OFFLINE. The interface worked like an alert/alarm interface when some components in the cluster were out of service (changed to OFFLINE). The consumers of this interface could not get notification for all status changes and configuration changes in the cluster. Cluster Event and its SNMP Interface in Oracle Solaris Cluster 4.2 The user model of the cluster event SNMP interface is the same as what was provided in the previous releases. The cluster event SNMP interface is not enabled by default on a freshly installed cluster; you can enable it by using the cluster event SNMP administration commands on any cluster nodes. Usually, you only need to enable it on one of the cluster nodes or a subset of the cluster nodes because all cluster nodes get the same cluster events. When it is enabled, it is responsible for two basic tasks. • Logs up to 100 most recent NOTICE or higher severity events to the MIB. • Sends SNMP traps to the hosts that are configured to receive the above events. The changes in the Oracle Solaris Cluster 4.2 release are1) Introduction of the NOTICE severity for the cluster configuration and status change events.The NOTICE severity is introduced for the cluster event in the 4.2 release. It is the severity between the INFO and WARNING severity. Now all severities for the cluster events are (from low to high) • INFO (not exposed to the SNMP interface) • NOTICE (newly introduced in the 4.2 release) • WARNING • ERROR • CRITICAL • FATAL In the 4.2 release, the cluster event system is enhanced to make sure at least one event with the NOTICE or a higher severity will be generated when there is a configuration or status change from a cluster component instance. In other words, the cluster events from a cluster with the NOTICE or higher severities will cover all status and configuration changes in the cluster (include all component instances). The cluster component instance here refers to an instance of the following cluster componentsnode, quorum, resource group, resource, network interface, device group, disk, zone cluster and geo cluster heartbeat. For example, pnode1 is an instance of the cluster node component, and oracleRG is an instance of the cluster resource group. With the introduction of the NOTICE severity event, when the cluster event SNMP interface is enabled, the consumers of the SNMP interface will get notification for all status and configuration changes in the cluster. A thrid-party system management platform with the cluster SNMP interface integration can generate alarms and clear alarms programmatically, because it can get notifications for the status change from ONLINE to OFFLINE and also from OFFLINE to ONLINE. 2) Customization for the cluster event SNMP interface • The number of events logged to the MIB is 100. When the number of events stored in the MIB reaches 100 and a new qualified event arrives, the oldest event will be removed before storing the new event to the MIB (FIFO, first in, first out). The 100 is the default and minimum value for the number of events stored in the MIB. It can be changed by setting the log_number property value using the clsnmpmib command. The maximum number that can be set for the property is 500. • The cluster event SNMP interface takes effect on the NOTICE or high severity events. The NOTICE severity is also the default and lowest event severity for the SNMP interface. The SNMP interface can be configured to take effect on other higher severity events, such as WARNING or higher severity events by setting the min_severity property to the WARNING. When the min_severity property is set to the WARNING, the cluster event SNMP interface would behave the same as the previous releases (prior to the 4.2 release). Examples, • Set the number of events stored in the MIB to 200 # clsnmpmib set -p log_number=200 event • Set the interface to take effect on WARNING or higher severity events. # clsnmpmib set -p min_severity=WARNING event Administering the Cluster Event SNMP Interface Oracle Solaris Cluster provides the following three commands to administer the SNMP interface. • clsnmpmib: administer the SNMP interface, and the MIB configuration. • clsnmphost: administer hosts for the SNMP traps • clsnmpuser: administer SNMP users (specific for SNMP v3 protocol) Only clsnmpmib is changed in the 4.2 release to support the aforementioned customization of the SNMP interface. Here are some simple examples using the commands. Examples: 1. Enable the cluster event SNMP interface on the local node # clsnmpmib enable event 2. Display the status of the cluster event SNMP interface on the local node # clsnmpmib show -v 3. Configure my_host to receive the cluster event SNMP traps. # clsnmphost add my_host Cluster Event SNMP Interface uses the common agent container SNMP adaptor, which is based on the JDMK SNMP implementation as its SNMP agent infrastructure. By default, the port number for the SNMP MIB is 11161, and the port number for the SNMP traps is 11162. The port numbers can be changed by using the cacaoadm. For example, # cacaoadm list-params Print all changeable parameters. The output includes the snmp-adaptor-port and snmp-adaptor-trap-port properties. # cacaoadm set-param snmp-adaptor-port=1161 Set the SNMP MIB port number to 1161. # cacaoadm set-param snmp-adaptor-trap-port=1162 Set the SNMP trap port number to 1162. The cluster event SNMP MIB is defined in sun-cluster-event-mib.mib, which is located in the /usr/cluster/lib/mibdirectory. Its OID is 1.3.6.1.4.1.42.2.80, that can be used to walk through the MIB data. Again, for more detail information about the cluster event SNMP interface, please see the Oracle Solaris Cluster 4.2 System Administration Guide. - Leland Chen 

    Read the article

  • Reinventing the Wheel – Automating Data Consistency Checks with Powershell

    - by Jonathan Kehayias
    When I started in my current position at the beginning of the year, one of the first things that I did was to schedule a sit down with the various teams of Analysts that exist in our organization to find out more about their systems.  One thing I am always interested in is the manual processes that people do routinely that might be able to be automated.   A couple of the analyst mentioned that they routinely run queries in their systems to identify issues so that they can proactively...(read more)

    Read the article

  • Guidance and Pricing for MSDN 2010

    - by John Alexander
    Sorry for the rather lengthy post here. I get asked this all the time so I decided to post it…Visual Studio 2010 editions will be available on April 12, 2010. Product Features Professional with MSDN Essentials Professional with MSDN Premium with MSDN Ultimate with MSDN Test Professional with MSDN Debugging and Diagnostics IntelliTrace (Historical Debugger)         Static Code Analysis       Code Metrics       Profiling       Debugger   Testing Tools Unit Testing   Code Coverage       Test Impact Analysis       Coded UI Test       Web Performance Testing         Load Testing1         Microsoft Test Manager 2010       Test Case Management2       Manual Test Execution       Fast-Forward for Manual Testing       Lab Management Configuration3       Integrated Development Environment Multiple Monitor Support   Multi-Targeting   One Click Web Deployment   JavaScript and jQuery Support   Extensible WPF-Based Environment Database Development Database Deployment       Database Change Management2       Database Unit Testing       Database Test Data Generation       Data Access   Development Platform Support Windows Development   Web Development   Office and SharePoint Development   Cloud Development   Customizable Development Experience   Architecture and Modeling Architecture Explorer         UML® 2.0 Compliant Diagrams (Activity, Use Case, Sequence, Class, Component)         Layer Diagram and Dependency Validation         Read-only diagrams (UML, Layer, DGML Graphs)         Lab Management Virtual environment setup & tear down3       Provision environment from template3       Checkpoint environment3       Team Foundation Server Version Control2   Work Item Tracking2   Build Automation2   Team Portal2   Reporting & Business Intelligence2   Agile Planning Workbook2   Microsoft Visual Studio Team Explorer 2010   Test Case Management2       MSDN Subscription – Software and Services for Production Use Windows Azure Platform 20 hrs/mo † 50 hrs/mo † 100 hrs/mo † 250 hrs/mo † n/a Microsoft Visual Studio Team Foundation Server 2010   Microsoft Visual Studio Team Foundation Server 2010 CAL   1 1 1 1 Microsoft Expression Studio 3       Microsoft Office Professional Plus 2010, Project Professional 2010, Visio Premium 2010 (following Office 2010 launch)       MSDN Subscription – Software for Development and Testing 4 Windows 7, Windows Server 2008 R2 and SQL Server 2008 Toolkits, Software Development Kits, Driver Development Kits Previous versions of Windows (client and server operation systems)   Previous versions of Microsoft SQL Server   Microsoft Office       Microsoft Dynamics       All other Servers       Windows Embedded operating systems       Teamprise         MSDN Subscription – Other Benefits Technical support incidents 0 2 4 4 2 Priority support in MSDN Forums Microsoft e-learning collections (typically 10 courses or 20 hours) 0 1 2 2 1 MSDN Flash newsletter MSDN Online Concierge MSDN Magazine   System Requirements View View View View View Buy from (MSRP) $799 $1,199 $5,469 $11,899 $2,169 Renew from (MSRP) $549 (upgrade) $799 $2,299 $3,799 $899 † Availability varies by country and subscription level.  Details available on the MSDN site 1. May require one or more Microsoft Visual Studio Load Test Virtual User Pack 2010 2. Requires Team Foundation Server and a Team Foundation Server CAL 3. Requires Microsoft Visual Studio Lab Management 2010 4. Per-user license allows unlimited installations and use for designing, developing, testing, and demonstrating applications. UML is a registered trademark of Object Management Group, Inc. Windows is either a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries.

    Read the article

  • Time Tracking on an Agile Team

    - by Stephen.Walther
    What’s the best way to handle time-tracking on an Agile team? Your gut reaction to this question might be to resist any type of time-tracking at all. After all, one of the principles of the Agile Manifesto is “Individuals and interactions over processes and tools”.  Forcing the developers on your team to track the amount of time that they devote to completing stories or tasks might seem like useless bureaucratic red tape: an impediment to getting real work done. I completely understand this reaction. I’ve been required to use time-tracking software in the past to account for each hour of my workday. It made me feel like Fred Flintstone punching in at the quarry mine and not like a professional. Why You Really Do Need Time-Tracking There are, however, legitimate reasons to track time spent on stories even when you are a member of an Agile team.  First, if you are working with an outside client, you might need to track the number of hours spent on different stories for the purposes of billing. There might be no way to avoid time-tracking if you want to get paid. Second, the Product Owner needs to know when the work on a story has gone over the original time estimated for the story. The Product Owner is concerned with Return On Investment. If the team has gone massively overtime on a story, then the Product Owner has a legitimate reason to halt work on the story and reconsider the story’s business value. Finally, you might want to track how much time your team spends on different types of stories or tasks. For example, if your team is spending 75% of their time doing testing then you might need to bring in more testers. Or, if 10% of your team’s time is expended performing a software build at the end of each iteration then it is time to consider better ways of automating the build process. Time-Tracking in SonicAgile For these reasons, we added time-tracking as a feature to SonicAgile which is our free Agile Project Management tool. We were heavily influenced by Jeff Sutherland (one of the founders of Scrum) in the way that we implemented time-tracking (see his article http://scrum.jeffsutherland.com/2007/03/time-tracking-is-anti-scrum-what-do-you.html). In SonicAgile, time-tracking is disabled by default. If you want to use this feature then the project owner must enable time-tracking in Project Settings. You can choose to estimate using either days or hours. If you are estimating at the level of stories then it makes more sense to choose days. Otherwise, if you are estimating at the level of tasks then it makes more sense to use hours. After you enable time-tracking then you can assign three estimates to a story: Original Estimate – This is the estimate that you enter when you first create a story. You don’t change this estimate. Time Spent – This is the amount of time that you have already devoted to the story. You update the time spent on each story during your daily standup meeting. Time Left – This is the amount of time remaining to complete the story. Again, you update the time left during your daily standup meeting. So when you first create a story, you enter an original estimate that becomes the time left. During each daily standup meeting, you update the time spent and time left for each story on the Kanban. If you had perfect predicative power, then the original estimate would always be the same as the sum of the time spent and the time left. For example, if you predict that a story will take 5 days to complete then on day 3, the story should have 3 days spent and 2 days left. Unfortunately, never in the history of mankind has anyone accurately predicted the exact amount of time that it takes to complete a story. For this reason, SonicAgile does not update the time spent and time left automatically. Each day, during the daily standup, your team should update the time spent and time left for each story. For example, the following table shows the history of the time estimates for a story that was originally estimated to take 3 days but, eventually, takes 5 days to complete: Day Original Estimate Time Spent Time Left Day 1 3 days 0 days 3 days Day 2 3 days 1 day 2 days Day 3 3 days 2 days 2 days Day 4 3 days 3 days 2 days Day 5 3 days 4 days 0 days In the table above, everything goes as predicted until you reach day 3. On day 3, the team realizes that the work will require an additional two days. The situation does not improve on day 4. All of the sudden, on day 5, all of the remaining work gets done. Real work often follows this pattern. There are long periods when nothing gets done punctuated by occasional and unpredictable bursts of progress. We designed SonicAgile to make it as easy as possible to track the time spent and time left on a story. Detecting when a Story Goes Over the Original Estimate Sometimes, stories take much longer than originally estimated. There’s a surprise. For example, you discover that a new software component is incompatible with existing software components. Or, you discover that you have to go through a month-long certification process to finish a story. In those cases, the Product Owner has a legitimate reason to halt work on a story and re-evaluate the business value of the story. For example, the Product Owner discovers that a story will require weeks to implement instead of days, then the story might not be worth the expense. SonicAgile displays a warning on both the Backlog and the Kanban when the time spent on a story goes over the original estimate. An icon of a clock is displayed. Time-Tracking and Tasks Another optional feature of SonicAgile is tasks. If you enable Tasks in Project Settings then you can break stories into one or more tasks. You can perform time-tracking at the level of a story or at the level of a task. If you don’t break a story into tasks then you can enter the time left and time spent for the story. As soon as you break a story into tasks, then you can no longer enter the time left and time spent at the level of the story. Instead, the time left and time spent for a story is rolled up from its tasks. On the Kanban, you can see how the time left and time spent for each task gets rolled up into each story. The progress bar for the story is rolled up from the progress bars for each task. The original estimate is never rolled up – even when you break a story into tasks. A story’s original estimate is entered separately from the original estimates of each of the story’s tasks. Summary Not every Agile team can avoid time-tracking. You might be forced to track time to get paid, to detect when you are spending too much time on a particular story, or to track the amount of time that you are devoting to different types of tasks. We designed time-tracking in SonicAgile to require the least amount of work to track the information that you need. Time-tracking is an optional feature. If you enable time-tracking then you can track the original estimate, time left, and time spent for each story and task. You can use time-tracking with SonicAgile for free. Register at http://SonicAgile.com.

    Read the article

  • DHCPv6: Provide IPv6 information in your local network

    Even though IPv6 might not be that important within your local network it might be good to get yourself into shape, and be able to provide some details of your infrastructure automatically to your network clients. This is the second article in a series on IPv6 configuration: Configure IPv6 on your Linux system DHCPv6: Provide IPv6 information in your local network Enabling DNS for IPv6 infrastructure Accessing your web server via IPv6 Piece of advice: This is based on my findings on the internet while reading other people's helpful articles and going through a couple of man-pages on my local system. IPv6 addresses for everyone (in your network) Okay, after setting up the configuration of your local system, it might be interesting to enable all your machines in your network to use IPv6. There are two options to solve this kind of requirement... Either you're busy like a bee and you go around to configure each and every system manually, or you're more the lazy and effective type of network administrator and you prefer to work with Dynamic Host Configuration Protocol (DHCP). Obviously, I'm of the second type. Enabling dynamic IPv6 address assignments can be done with a new or an existing instance of a DHCPd. In case of Ubuntu-based installation this might be isc-dhcp-server. The isc-dhcp-server allows address pooling for IP and IPv6 within the same package, you just have to run to independent daemons for each protocol version. First, check whether isc-dhcp-server is already installed and maybe running your machine like so: $ service isc-dhcp-server6 status In case, that the service is unknown, you have to install it like so: $ sudo apt-get install isc-dhcp-server Please bear in mind that there is no designated installation package for IPv6. Okay, next you have to create a separate configuration file for IPv6 address pooling and network parameters called /etc/dhcp/dhcpd6.conf. This file is not automatically provided by the package, compared to IPv4. Again, use your favourite editor and put the following lines: $ sudo nano /etc/dhcp/dhcpd6.conf authoritative;default-lease-time 14400; max-lease-time 86400;log-facility local7;subnet6 2001:db8:bad:a55::/64 {    option dhcp6.name-servers 2001:4860:4860::8888, 2001:4860:4860::8844;    option dhcp6.domain-search "ios.mu";    range6 2001:db8:bad:a55::100 2001:db8:bad:a55::199;    range6 2001:db8:bad:a55::/64 temporary;} Next, save the file and start the daemon as a foreground process to see whether it is going to listen to requests or not, like so: $ sudo /usr/sbin/dhcpd -6 -d -cf /etc/dhcp/dhcpd6.conf eth0 The parameters are explained quickly as -6 we want to run as a DHCPv6 server, -d we are sending log messages to the standard error descriptor (so you should monitor your /var/log/syslog file, too), and we explicitely want to use our newly created configuration file (-cf). You might also use the command switch -t to test the configuration file prior to running the server. In my case, I ended up with a couple of complaints by the server, especially reporting that the necessary lease file wouldn't exist. So, ensure that the lease file for your IPv6 address assignments is present: $ sudo touch /var/lib/dhcp/dhcpd6.leases$ sudo chown dhcpd:dhcpd /var/lib/dhcp/dhcpd6.leases Now, you should be good to go. Stop your foreground process and try to run the DHCPv6 server as a service on your system: $ sudo service isc-dhcp-server6 startisc-dhcp-server6 start/running, process 15883 Check your log file /var/log/syslog for any kind of problems. Refer to the man-pages of isc-dhcp-server and you might check out Chapter 22.6 of Peter Bieringer's IPv6 Howto. The instructions regarding DHCPv6 on the Ubuntu Wiki are not as complete as expected and it might not be as helpful as this article or Peter's HOWTO. But see for yourself. Does the client get an IPv6 address? Running a DHCPv6 server on your local network surely comes in handy but it has to work properly. The following paragraphs describe briefly how to check the IPv6 configuration of your clients, Linux - ifconfig or ip command First, you have enable IPv6 on your Linux by specifying the necessary directives in the /etc/network/interfaces file, like so: $ sudo nano /etc/network/interfaces iface eth1 inet6 dhcp Note: Your network device might be eth0 - please don't just copy my configuration lines. Then, either restart your network subsystem, or enable the device manually using the dhclient command with IPv6 switch, like so: $ sudo dhclient -6 You would either use the ifconfig or (if installed) the ip command to check the configuration of your network device like so: $ sudo ifconfig eth1eth1      Link encap:Ethernet  HWaddr 00:1d:09:5d:8d:98            inet addr:192.168.160.147  Bcast:192.168.160.255  Mask:255.255.255.0          inet6 addr: 2001:db8:bad:a55::193/64 Scope:Global          inet6 addr: fe80::21d:9ff:fe5d:8d98/64 Scope:Link          UP BROADCAST RUNNING MULTICAST  MTU:1500  Metric:1 Looks good, the client has an IPv6 assignment. Now, let's see whether DNS information has been provided, too. $ less /etc/resolv.conf # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8)#     DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTENnameserver 2001:4860:4860::8888nameserver 2001:4860:4860::8844nameserver 192.168.1.2nameserver 127.0.1.1search ios.mu Nicely done. Windows - netsh Per description on TechNet the netsh is defined as following: "Netsh is a command-line scripting utility that allows you to, either locally or remotely, display or modify the network configuration of a computer that is currently running. Netsh also provides a scripting feature that allows you to run a group of commands in batch mode against a specified computer. Netsh can also save a configuration script in a text file for archival purposes or to help you configure other servers." And even though TechNet states that it applies to Windows Server (only), it is also available on Windows client operating systems, like Vista, Windows 7 and Windows 8. In order to get or even set information related to IPv6 protocol, we have to switch the netsh interface context prior to our queries. Open a command prompt in Windows and run the following statements: C:\Users\joki>netshnetsh>interface ipv6netsh interface ipv6>show interfaces Select the device index from the Idx column to get more details about the IPv6 address and DNS server information (here: I'm going to use my WiFi device with device index 11), like so: netsh interface ipv6>show address 11 Okay, address information has been provided. Now, let's check the details about DNS and resolving host names: netsh interface ipv6> show dnsservers 11 Okay, that looks good already. Our Windows client has a valid IPv6 address lease with lifetime information and details about the configured DNS servers. Talking about DNS server... Your clients should be able to connect to your network servers via IPv6 using hostnames instead of IPv6 addresses. Please read on about how to enable a local named with IPv6.

    Read the article

  • VS 2010 Debugger Improvements (BreakPoints, DataTips, Import/Export)

    - by ScottGu
    This is the twenty-first in a series of blog posts I’m doing on the VS 2010 and .NET 4 release.  Today’s blog post covers a few of the nice usability improvements coming with the VS 2010 debugger.  The VS 2010 debugger has a ton of great new capabilities.  Features like Intellitrace (aka historical debugging), the new parallel/multithreaded debugging capabilities, and dump debuging support typically get a ton of (well deserved) buzz and attention when people talk about the debugging improvements with this release.  I’ll be doing blog posts in the future that demonstrate how to take advantage of them as well.  With today’s post, though, I thought I’d start off by covering a few small, but nice, debugger usability improvements that were also included with the VS 2010 release, and which I think you’ll find useful. Breakpoint Labels VS 2010 includes new support for better managing debugger breakpoints.  One particularly useful feature is called “Breakpoint Labels” – it enables much better grouping and filtering of breakpoints within a project or across a solution.  With previous releases of Visual Studio you had to manage each debugger breakpoint as a separate item. Managing each breakpoint separately can be a pain with large projects and for cases when you want to maintain “logical groups” of breakpoints that you turn on/off depending on what you are debugging.  Using the new VS 2010 “breakpoint labeling” feature you can now name these “groups” of breakpoints and manage them as a unit. Grouping Multiple Breakpoints Together using a Label Below is a screen-shot of the breakpoints window within Visual Studio 2010.  This lists all of the breakpoints defined within my solution (which in this case is the ASP.NET MVC 2 code base): The first and last breakpoint in the list above breaks into the debugger when a Controller instance is created or released by the ASP.NET MVC Framework. Using VS 2010, I can now select these two breakpoints, right-click, and then select the new “Edit labels…” menu command to give them a common label/name (making them easier to find and manage): Below is the dialog that appears when I select the “Edit labels” command.  We can use it to create a new string label for our breakpoints or select an existing one we have already defined.  In this case we’ll create a new label called “Lifetime Management” to describe what these two breakpoints cover: When we press the OK button our two selected breakpoints will be grouped under the newly created “Lifetime Management” label: Filtering/Sorting Breakpoints by Label We can use the “Search” combobox to quickly filter/sort breakpoints by label.  Below we are only showing those breakpoints with the “Lifetime Management” label: Toggling Breakpoints On/Off by Label We can also toggle sets of breakpoints on/off by label group.  We can simply filter by the label group, do a Ctrl-A to select all the breakpoints, and then enable/disable all of them with a single click: Importing/Exporting Breakpoints VS 2010 now supports importing/exporting breakpoints to XML files – which you can then pass off to another developer, attach to a bug report, or simply re-load later.  To export only a subset of breakpoints, you can filter by a particular label and then click the “Export breakpoint” button in the Breakpoints window: Above I’ve filtered my breakpoint list to only export two particular breakpoints (specific to a bug that I’m chasing down).  I can export these breakpoints to an XML file and then attach it to a bug report or email – which will enable another developer to easily setup the debugger in the correct state to investigate it on a separate machine.  Pinned DataTips Visual Studio 2010 also includes some nice new “DataTip pinning” features that enable you to better see and track variable and expression values when in the debugger.  Simply hover over a variable or expression within the debugger to expose its DataTip (which is a tooltip that displays its value)  – and then click the new “pin” button on it to make the DataTip always visible: You can “pin” any number of DataTips you want onto the screen.  In addition to pinning top-level variables, you can also drill into the sub-properties on variables and pin them as well.  Below I’ve “pinned” three variables: “category”, “Request.RawUrl” and “Request.LogonUserIdentity.Name”.  Note that these last two variable are sub-properties of the “Request” object.   Associating Comments with Pinned DataTips Hovering over a pinned DataTip exposes some additional UI within the debugger: Clicking the comment button at the bottom of this UI expands the DataTip - and allows you to optionally add a comment with it: This makes it really easy to attach and track debugging notes: Pinned DataTips are usable across both Debug Sessions and Visual Studio Sessions Pinned DataTips can be used across multiple debugger sessions.  This means that if you stop the debugger, make a code change, and then recompile and start a new debug session - any pinned DataTips will still be there, along with any comments you associate with them.  Pinned DataTips can also be used across multiple Visual Studio sessions.  This means that if you close your project, shutdown Visual Studio, and then later open the project up again – any pinned DataTips will still be there, along with any comments you associate with them. See the Value from Last Debug Session (Great Code Editor Feature) How many times have you ever stopped the debugger only to go back to your code and say: $#@! – what was the value of that variable again??? One of the nice things about pinned DataTips is that they keep track of their “last value from debug session” – and you can look these values up within the VB/C# code editor even when the debugger is no longer running.  DataTips are by default hidden when you are in the code editor and the debugger isn’t running.  On the left-hand margin of the code editor, though, you’ll find a push-pin for each pinned DataTip that you’ve previously setup: Hovering your mouse over a pinned DataTip will cause it to display on the screen.  Below you can see what happens when I hover over the first pin in the editor - it displays our debug session’s last values for the “Request” object DataTip along with the comment we associated with them: This makes it much easier to keep track of state and conditions as you toggle between code editing mode and debugging mode on your projects. Importing/Exporting Pinned DataTips As I mentioned earlier in this post, pinned DataTips are by default saved across Visual Studio sessions (you don’t need to do anything to enable this). VS 2010 also now supports importing/exporting pinned DataTips to XML files – which you can then pass off to other developers, attach to a bug report, or simply re-load later. Combined with the new support for importing/exporting breakpoints, this makes it much easier for multiple developers to share debugger configurations and collaborate across debug sessions. Summary Visual Studio 2010 includes a bunch of great new debugger features – both big and small.  Today’s post shared some of the nice debugger usability improvements. All of the features above are supported with the Visual Studio 2010 Professional edition (the Pinned DataTip features are also supported in the free Visual Studio 2010 Express Editions)  I’ll be covering some of the “big big” new debugging features like Intellitrace, parallel/multithreaded debugging, and dump file analysis in future blog posts.  Hope this helps, Scott P.S. In addition to blogging, I am also now using Twitter for quick updates and to share links. Follow me at: twitter.com/scottgu

    Read the article

  • Ant trouble with environment variables on Ubuntu

    - by Inaimathi
    Having some trouble with with ant reading environment variables in Ubuntu 9.10. Specifically, the build tasks my company uses has a token like ${env.CATALINA_HOME] in the main build.xml. I set CATALINA_HOME to the correct value in /etc/environment, ~/.pam_environment and (just to be safe) my .bashrc. I can see the correct value when I run printenv from bash, or when I eval (getenv "CATALINA_HOME") in emacs. Ant refuses to build to the correct directory though; instead I get a folder named ${env.CATALINA_HOME} in the same directory as my build.xml. Any idea what's happening there, and/or how to fix it?

    Read the article

  • Static background noise while using new headset Ubuntu 13.04

    - by ThundLayr
    Today I bought a new gaming headset (Gx-Gaming Lychas), and when I tried to record some gameplay-comentary I noticed that there always is a static background noise, I just recorded an example so you guys can listen it (no downloaded needed): http://www47.zippyshare.com/v/65167832/file.html I'm using Kubuntu 13.04 and Kernel version is 3.8.0-19, my laptop is an Acer Travelmate 5760Z, I tried tons of configurations on Alsamixer and none of them made result, I really need to get this working so any kind of help will be very aprecciated. cat /proc/asound/cards: 0 [PCH ]: HDA-Intel - HDA Intel PCH HDA Intel PCH at 0xc6400000 irq 44 cat /proc/asound/card0/codec#0 Codec: Conexant CX20588 Address: 0 AFG Function Id: 0x1 (unsol 1) Vendor Id: 0x14f1506c Subsystem Id: 0x10250574 Revision Id: 0x100003 No Modem Function Group found Default PCM: rates [0x160]: 44100 48000 96000 bits [0xe]: 16 20 24 formats [0x1]: PCM Default Amp-In caps: N/A Default Amp-Out caps: N/A State of AFG node 0x01: Power states: D0 D1 D2 D3 D3cold CLKSTOP EPSS Power: setting=D0, actual=D0 GPIO: io=4, o=0, i=0, unsolicited=1, wake=0 IO[0]: enable=0, dir=0, wake=0, sticky=0, data=0, unsol=0 IO[1]: enable=0, dir=0, wake=0, sticky=0, data=0, unsol=0 IO[2]: enable=0, dir=0, wake=0, sticky=0, data=0, unsol=0 IO[3]: enable=0, dir=0, wake=0, sticky=0, data=0, unsol=0 Node 0x10 [Audio Output] wcaps 0xc1d: Stereo Amp-Out R/L Control: name="Headphone Playback Volume", index=0, device=0 ControlAmp: chs=3, dir=Out, idx=0, ofs=0 Control: name="Headphone Playback Switch", index=0, device=0 ControlAmp: chs=3, dir=Out, idx=0, ofs=0 Device: name="CX20588 Analog", type="Audio", device=0 Amp-Out caps: ofs=0x4a, nsteps=0x4a, stepsize=0x03, mute=1 Amp-Out vals: [0x4a 0x4a] Converter: stream=8, channel=0 PCM: rates [0x560]: 44100 48000 96000 192000 bits [0xe]: 16 20 24 formats [0x1]: PCM Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x11 [Audio Output] wcaps 0xc1d: Stereo Amp-Out R/L Control: name="Speaker Playback Volume", index=0, device=0 ControlAmp: chs=3, dir=Out, idx=0, ofs=0 Control: name="Speaker Playback Switch", index=0, device=0 ControlAmp: chs=3, dir=Out, idx=0, ofs=0 Amp-Out caps: ofs=0x4a, nsteps=0x4a, stepsize=0x03, mute=1 Amp-Out vals: [0x80 0x80] Converter: stream=8, channel=0 PCM: rates [0x560]: 44100 48000 96000 192000 bits [0xe]: 16 20 24 formats [0x1]: PCM Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x12 [Audio Output] wcaps 0x611: Stereo Digital Converter: stream=0, channel=0 Digital: Digital category: 0x0 IEC Coding Type: 0x0 PCM: rates [0x160]: 44100 48000 96000 bits [0xe]: 16 20 24 formats [0x5]: PCM AC3 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x13 [Beep Generator Widget] wcaps 0x70000c: Mono Amp-Out Control: name="Beep Playback Volume", index=0, device=0 ControlAmp: chs=1, dir=Out, idx=0, ofs=0 Control: name="Beep Playback Switch", index=0, device=0 ControlAmp: chs=1, dir=Out, idx=0, ofs=0 Amp-Out caps: ofs=0x07, nsteps=0x07, stepsize=0x0f, mute=0 Amp-Out vals: [0x00] Node 0x14 [Audio Input] wcaps 0x100d1b: Stereo Amp-In R/L Control: name="Capture Volume", index=0, device=0 ControlAmp: chs=3, dir=In, idx=0, ofs=0 Control: name="Capture Switch", index=0, device=0 ControlAmp: chs=3, dir=In, idx=0, ofs=0 Device: name="CX20588 Analog", type="Audio", device=0 Amp-In caps: ofs=0x4a, nsteps=0x50, stepsize=0x03, mute=1 Amp-In vals: [0x50 0x50] [0x80 0x80] [0x80 0x80] [0x80 0x80] Converter: stream=4, channel=0 SDI-Select: 0 PCM: rates [0x160]: 44100 48000 96000 bits [0xe]: 16 20 24 formats [0x1]: PCM Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 4 0x17* 0x18 0x23 0x24 Node 0x15 [Audio Input] wcaps 0x100d1b: Stereo Amp-In R/L Amp-In caps: ofs=0x4a, nsteps=0x50, stepsize=0x03, mute=1 Amp-In vals: [0x4a 0x4a] [0x4a 0x4a] [0x4a 0x4a] [0x4a 0x4a] Converter: stream=0, channel=0 SDI-Select: 0 PCM: rates [0x160]: 44100 48000 96000 bits [0xe]: 16 20 24 formats [0x1]: PCM Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 4 0x17* 0x18 0x23 0x24 Node 0x16 [Audio Input] wcaps 0x100d1b: Stereo Amp-In R/L Amp-In caps: ofs=0x4a, nsteps=0x50, stepsize=0x03, mute=1 Amp-In vals: [0x4a 0x4a] [0x4a 0x4a] [0x4a 0x4a] [0x4a 0x4a] Converter: stream=0, channel=0 SDI-Select: 0 PCM: rates [0x160]: 44100 48000 96000 bits [0xe]: 16 20 24 formats [0x1]: PCM Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 4 0x17* 0x18 0x23 0x24 Node 0x17 [Audio Selector] wcaps 0x30050d: Stereo Amp-Out Control: name="Mic Boost Volume", index=0, device=0 ControlAmp: chs=3, dir=Out, idx=0, ofs=0 Amp-Out caps: ofs=0x00, nsteps=0x04, stepsize=0x27, mute=0 Amp-Out vals: [0x04 0x04] Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 4 0x1a 0x1b* 0x1d 0x1e Node 0x18 [Audio Selector] wcaps 0x30050d: Stereo Amp-Out Amp-Out caps: ofs=0x00, nsteps=0x04, stepsize=0x27, mute=0 Amp-Out vals: [0x00 0x00] Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 4 0x1a* 0x1b 0x1d 0x1e Node 0x19 [Pin Complex] wcaps 0x400581: Stereo Control: name="Headphone Jack", index=0, device=0 Pincap 0x0000001c: OUT HP Detect Pin Default 0x04214040: [Jack] HP Out at Ext Right Conn = 1/8, Color = Green DefAssociation = 0x4, Sequence = 0x0 Pin-ctls: 0xc0: OUT HP Unsolicited: tag=01, enabled=1 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 2 0x10* 0x11 Node 0x1a [Pin Complex] wcaps 0x400481: Stereo Control: name="Internal Mic Phantom Jack", index=0, device=0 Pincap 0x00001324: IN Detect Vref caps: HIZ 50 80 Pin Default 0x90a70130: [Fixed] Mic at Int N/A Conn = Analog, Color = Unknown DefAssociation = 0x3, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x24: IN VREF_80 Unsolicited: tag=00, enabled=0 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x1b [Pin Complex] wcaps 0x400581: Stereo Control: name="Mic Jack", index=0, device=0 Pincap 0x00011334: IN OUT EAPD Detect Vref caps: HIZ 50 80 EAPD 0x0: Pin Default 0x04a19020: [Jack] Mic at Ext Right Conn = 1/8, Color = Pink DefAssociation = 0x2, Sequence = 0x0 Pin-ctls: 0x24: IN VREF_80 Unsolicited: tag=02, enabled=1 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 2 0x10* 0x11 Node 0x1c [Pin Complex] wcaps 0x400581: Stereo Pincap 0x00000014: OUT Detect Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x40: OUT Unsolicited: tag=00, enabled=0 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 2 0x10* 0x11 Node 0x1d [Pin Complex] wcaps 0x400581: Stereo Pincap 0x00010034: IN OUT EAPD Detect EAPD 0x0: Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x40: OUT Unsolicited: tag=00, enabled=0 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 2 0x10* 0x11 Node 0x1e [Pin Complex] wcaps 0x400481: Stereo Pincap 0x00000024: IN Detect Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x00: Unsolicited: tag=00, enabled=0 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x1f [Pin Complex] wcaps 0x400501: Stereo Control: name="Speaker Phantom Jack", index=0, device=0 Pincap 0x00000010: OUT Pin Default 0x92170110: [Fixed] Speaker at Int Front Conn = Analog, Color = Unknown DefAssociation = 0x1, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x40: OUT Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 2 0x10 0x11* Node 0x20 [Pin Complex] wcaps 0x400781: Stereo Digital Pincap 0x00000010: OUT Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x00: Unsolicited: tag=00, enabled=0 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 1 0x12 Node 0x21 [Audio Output] wcaps 0x611: Stereo Digital Converter: stream=0, channel=0 Digital: Digital category: 0x0 IEC Coding Type: 0x0 PCM: rates [0x160]: 44100 48000 96000 bits [0xe]: 16 20 24 formats [0x5]: PCM AC3 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x22 [Pin Complex] wcaps 0x400781: Stereo Digital Pincap 0x00000010: OUT Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x00: Unsolicited: tag=00, enabled=0 Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 1 0x21 Node 0x23 [Pin Complex] wcaps 0x40040b: Stereo Amp-In Amp-In caps: ofs=0x00, nsteps=0x04, stepsize=0x2f, mute=0 Amp-In vals: [0x00 0x00] Pincap 0x00000020: IN Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x00: Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Node 0x24 [Audio Mixer] wcaps 0x20050b: Stereo Amp-In Amp-In caps: ofs=0x4a, nsteps=0x4a, stepsize=0x03, mute=1 Amp-In vals: [0x00 0x00] [0x00 0x00] Power states: D0 D1 D2 D3 D3cold EPSS Power: setting=D0, actual=D0 Connection: 2 0x10 0x11 Node 0x25 [Vendor Defined Widget] wcaps 0xf00000: Mono

    Read the article

  • Lock Question - 'U' lock vs. 'X' lock

    - by Randy Minder
    I have a couple questions concerning Update (U) locks and Exclusive (X) locks. 1) Am I correct that an 'X' lock is put on a resource when the resource is about to get updated? 2) I'm a little fuzzy on U locks. Am I correct that a U lock is applied when a resource is read and SQL Server thinks it might need to update the resource later? If this is correct, would a 'U' lock only get applied when a read is being done within the context of a transaction? I guess I'm trying to understand under what circumstances SQL Server thinks it might need to update later a row it just read now. Thanks - Randy

    Read the article

  • SQL SERVER – Faster SQL Server Databases and Applications – Power and Control with SafePeak Caching Options

    - by Pinal Dave
    Update: This blog post is written based on the SafePeak, which is available for free download. Today, I’d like to examine more closely one of my preferred technologies for accelerating SQL Server databases, SafePeak. Safepeak’s software provides a variety of advanced data caching options, techniques and tools to accelerate the performance and scalability of SQL Server databases and applications. I’d like to look more closely at some of these options, as some of these capabilities could help you address lagging database and performance on your systems. To better understand the available options, it is best to start by understanding the difference between the usual “Basic Caching” vs. SafePeak’s “Dynamic Caching”. Basic Caching Basic Caching (or the stale and static cache) is an ability to put the results from a query into cache for a certain period of time. It is based on TTL, or Time-to-live, and is designed to stay in cache no matter what happens to the data. For example, although the actual data can be modified due to DML commands (update/insert/delete), the cache will still hold the same obsolete query data. Meaning that with the Basic Caching is really static / stale cache.  As you can tell, this approach has its limitations. Dynamic Caching Dynamic Caching (or the non-stale cache) is an ability to put the results from a query into cache while maintaining the cache transaction awareness looking for possible data modifications. The modifications can come as a result of: DML commands (update/insert/delete), indirect modifications due to triggers on other tables, executions of stored procedures with internal DML commands complex cases of stored procedures with multiple levels of internal stored procedures logic. When data modification commands arrive, the caching system identifies the related cache items and evicts them from cache immediately. In the dynamic caching option the TTL setting still exists, although its importance is reduced, since the main factor for cache invalidation (or cache eviction) become the actual data updates commands. Now that we have a basic understanding of the differences between “basic” and “dynamic” caching, let’s dive in deeper. SafePeak: A comprehensive and versatile caching platform SafePeak comes with a wide range of caching options. Some of SafePeak’s caching options are automated, while others require manual configuration. Together they provide a complete solution for IT and Data managers to reach excellent performance acceleration and application scalability for  a wide range of business cases and applications. Automated caching of SQL Queries: Fully/semi-automated caching of all “read” SQL queries, containing any types of data, including Blobs, XMLs, Texts as well as all other standard data types. SafePeak automatically analyzes the incoming queries, categorizes them into SQL Patterns, identifying directly and indirectly accessed tables, views, functions and stored procedures; Automated caching of Stored Procedures: Fully or semi-automated caching of all read” stored procedures, including procedures with complex sub-procedure logic as well as procedures with complex dynamic SQL code. All procedures are analyzed in advance by SafePeak’s  Metadata-Learning process, their SQL schemas are parsed – resulting with a full understanding of the underlying code, objects dependencies (tables, views, functions, sub-procedures) enabling automated or semi-automated (manually review and activate by a mouse-click) cache activation, with full understanding of the transaction logic for cache real-time invalidation; Transaction aware cache: Automated cache awareness for SQL transactions (SQL and in-procs); Dynamic SQL Caching: Procedures with dynamic SQL are pre-parsed, enabling easy cache configuration, eliminating SQL Server load for parsing time and delivering high response time value even in most complicated use-cases; Fully Automated Caching: SQL Patterns (including SQL queries and stored procedures) that are categorized by SafePeak as “read and deterministic” are automatically activated for caching; Semi-Automated Caching: SQL Patterns categorized as “Read and Non deterministic” are patterns of SQL queries and stored procedures that contain reference to non-deterministic functions, like getdate(). Such SQL Patterns are reviewed by the SafePeak administrator and in usually most of them are activated manually for caching (point and click activation); Fully Dynamic Caching: Automated detection of all dependent tables in each SQL Pattern, with automated real-time eviction of the relevant cache items in the event of “write” commands (a DML or a stored procedure) to one of relevant tables. A default setting; Semi Dynamic Caching: A manual cache configuration option enabling reducing the sensitivity of specific SQL Patterns to “write” commands to certain tables/views. An optimization technique relevant for cases when the query data is either known to be static (like archive order details), or when the application sensitivity to fresh data is not critical and can be stale for short period of time (gaining better performance and reduced load); Scheduled Cache Eviction: A manual cache configuration option enabling scheduling SQL Pattern cache eviction based on certain time(s) during a day. A very useful optimization technique when (for example) certain SQL Patterns can be cached but are time sensitive. Example: “select customers that today is their birthday”, an SQL with getdate() function, which can and should be cached, but the data stays relevant only until 00:00 (midnight); Parsing Exceptions Management: Stored procedures that were not fully parsed by SafePeak (due to too complex dynamic SQL or unfamiliar syntax), are signed as “Dynamic Objects” with highest transaction safety settings (such as: Full global cache eviction, DDL Check = lock cache and check for schema changes, and more). The SafePeak solution points the user to the Dynamic Objects that are important for cache effectiveness, provides easy configuration interface, allowing you to improve cache hits and reduce cache global evictions. Usually this is the first configuration in a deployment; Overriding Settings of Stored Procedures: Override the settings of stored procedures (or other object types) for cache optimization. For example, in case a stored procedure SP1 has an “insert” into table T1, it will not be allowed to be cached. However, it is possible that T1 is just a “logging or instrumentation” table left by developers. By overriding the settings a user can allow caching of the problematic stored procedure; Advanced Cache Warm-Up: Creating an XML-based list of queries and stored procedure (with lists of parameters) for periodically automated pre-fetching and caching. An advanced tool allowing you to handle more rare but very performance sensitive queries pre-fetch them into cache allowing high performance for users’ data access; Configuration Driven by Deep SQL Analytics: All SQL queries are continuously logged and analyzed, providing users with deep SQL Analytics and Performance Monitoring. Reduce troubleshooting from days to minutes with database objects and SQL Patterns heat-map. The performance driven configuration helps you to focus on the most important settings that bring you the highest performance gains. Use of SafePeak SQL Analytics allows continuous performance monitoring and analysis, easy identification of bottlenecks of both real-time and historical data; Cloud Ready: Available for instant deployment on Amazon Web Services (AWS). As you can see, there are many options to configure SafePeak’s SQL Server database and application acceleration caching technology to best fit a lot of situations. If you’re not familiar with their technology, they offer free-trial software you can download that comes with a free “help session” to help get you started. You can access the free trial here. Also, SafePeak is available to use on Amazon Cloud. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: PostADay, SQL, SQL Authority, SQL Performance, SQL Query, SQL Server, SQL Tips and Tricks, T SQL

    Read the article

  • Ubuntu Preseed set Norwegian Keyboard?

    - by Vangelis Tasoulas
    It's been a couple of days now that I am trying to make a fully automated unattended installation. I managed to make it work with Ubuntu/Cobbler and a preseed file, but I cannot set the correct keyboard layout which is Norwegian in this case. I am doing the tests on a virtual machine and when I am going with a normal manual installation (no preseed) everything is working fine. When I am using the preseed file, I always end up with an "English (US)" keyboard no matter the many different options I have tried. I can change it manually with the "dpkg-reconfigure keyboard-configuration" command, but that's not the case. It should be handled automatically using the preseed file. I am using DEBCONF_DEBUG=5 when the grub is loading, and as I see in "/var/log/installer/syslog" file after the installation has finished, the preseeding commands are accepted. Can anyone help on this? The preseed file I am using is following: d-i debian-installer/country string NO d-i debian-installer/language string en_US:en d-i debian-installer/locale string en_US.UTF-8 d-i console-setup/ask_detect boolean false d-i keyboard-configuration/layout select Norwegian d-i keyboard-configuration/variant select Norwegian d-i keyboard-configuration/modelcode string pc105 d-i keyboard-configuration/layoutcode string no d-i keyboard-configuration/xkb-keymap select no d-i netcfg/choose_interface select auto d-i netcfg/get_hostname string myhostname d-i netcfg/get_domain string simula.no d-i hw-detect/load_firmware boolean true d-i mirror/country string manual d-i mirror/http/hostname string ftp.uninett.no d-i mirror/http/directory string /ubuntu d-i mirror/http/proxy string http://10.0.1.253:3142/ d-i mirror/codename string precise d-i mirror/suite string precise d-i clock-setup/utc boolean true d-i time/zone string Europe/Oslo d-i clock-setup/ntp boolean true d-i clock-setup/ntp-server string 10.0.1.254 d-i partman-auto/method string lvm partman-auto-lvm partman-auto-lvm/new_vg_name string vg0 d-i partman-auto/purge_lvm_from_device boolean true d-i partman-lvm/device_remove_lvm boolean true d-i partman-md/device_remove_md boolean true d-i partman-lvm/confirm boolean true d-i partman-lvm/confirm_nooverwrite boolean true d-i partman-auto-lvm/guided_size string max d-i partman-auto/choose_recipe select 30atomic d-i partman/default_filesystem string ext4 d-i partman-partitioning/confirm_write_new_label boolean true d-i partman/choose_partition select finish d-i partman/confirm boolean true d-i partman/confirm_nooverwrite boolean true d-i partman/mount_style select uuid d-i passwd/root-login boolean false d-i passwd/make-user boolean true d-i passwd/user-fullname string vangelis d-i passwd/username string vangelis d-i passwd/user-password-crypted password $6$asdafdsdfasdfasdf d-i passwd/user-uid string d-i user-setup/allow-password-weak boolean false d-i passwd/user-default-groups string adm cdrom dialout lpadmin plugdev sambashare d-i user-setup/encrypt-home boolean false d-i apt-setup/restricted boolean true d-i apt-setup/universe boolean true d-i apt-setup/backports boolean true d-i apt-setup/services-select multiselect security d-i apt-setup/security_host string security.ubuntu.com d-i apt-setup/security_path string /ubuntu tasksel tasksel/first multiselect Basic Ubuntu server, OpenSSH server d-i pkgsel/include string build-essential htop vim nmap ntp d-i pkgsel/upgrade select safe-upgrade d-i pkgsel/update-policy select none d-i pkgsel/updatedb boolean true d-i grub-installer/only_debian boolean true d-i grub-installer/with_other_os boolean true d-i finish-install/keep-consoles boolean false d-i finish-install/reboot_in_progress note d-i cdrom-detect/eject boolean true d-i debian-installer/exit/halt boolean false d-i debian-installer/exit/poweroff boolean false

    Read the article

  • How to Add Control Panel to “My Computer” in Windows 7 or Vista

    - by The Geek
    Back in the Windows XP days, you could easily add Control Panel to My Computer with a simple checkbox in the folder view settings. Windows 7 and Vista don’t make this quite as easy, but there’s still a way to get it back. To make this tweak, we’ll be doing a quick registry hack, but there’s a downloadable version provided as well. Manual Registry Tweak to Add Control Panel Open up regedit.exe through the start menu search or run box, and then browse down to the following key: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\MyComputer\NameSpace Now that you’re there, you’ll need to right-click and create a new key… If you want to add the regular Control Panel view, with the categories, you’ll need to use one GUID as the name of the key. If you want the icon view instead, you can use the other key. Here they are: Category View:  {26EE0668-A00A-44D7-9371-BEB064C98683} Icon View: {21EC2020-3AEA-1069-A2DD-08002B30309D} Once you’re done, it should look like this: Now over in the Computer view, just hit the F5 key to refresh the panel, and you should see the new icon pop up in the list: Now when you click on the icon you’ll be taken to Control Panel. If you didn’t know how to change the view before, you can use the drop-down box on the right-hand side to switch between Category and icon view. Downloadable Registry Hack Rather than deal with manual registry editing, you can simply download the file, extract it, and then either double-click on the AddCategoryControlPanel.reg to add the Category view icon, or AddIconControlPanel.reg to add the other icon. There’s an uninstall script provided for each. Download ControlPanelMyComputer Registry Hack from howtogeek.com Similar Articles Productive Geek Tips Disable User Account Control (UAC) the Easy Way on Win 7 or VistaHow To Figure Out Your PC’s Host Name From the Command PromptRestore Missing Desktop Icons in Windows 7 or VistaNew Vista Syntax for Opening Control Panel Items from the Command-lineAdd Registry Editor to Control Panel TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Have Fun Editing Photo Editing with Citrify Outlook Connector Upgrade Error Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7 Microsoft’s “How Do I ?” Videos Home Networks – How do they look like & the problems they cause

    Read the article

  • links for 2010-03-12

    - by Bob Rhubart
    Roddy Rodstein: Oracle VM 2.2 SAN, iSCSI and NFS Back-end Storage Configurations The latest chapter in Roddy Rodstein's "Underground Oracle VM Manual." (tags: oraclevm virtualiztion oracle otn)

    Read the article

  • New ways for backup, recovery and restore of Essbase Block Storage databases – part 2 by Bernhard Kinkel

    - by Alexandra Georgescu
    After discussing in the first part of this article new options in Essbase for the general backup and restore, this second part will deal with the also rather new feature of Transaction Logging and Replay, which was released in version 11.1, enhancing existing restore options. Tip: Transaction logging and replay cannot be used for aggregate storage databases. Please refer to the Oracle Hyperion Enterprise Performance Management System Backup and Recovery Guide (rel. 11.1.2.1). Even if backups are done on a regular, frequent base, subsequent data entries, loads or calculations would not be reflected in a restored database. Activating Transaction Logging could fill that gap and provides you with an option to capture these post-backup transactions for later replay. The following table shows, which are the transactions that could be logged when Transaction Logging is enabled: In order to activate its usage, corresponding statements could be added to the Essbase.cfg file, using the TRANSACTIONLOGLOCATION command. The complete syntax reads: TRANSACTIONLOGLOCATION [ appname [ dbname]] LOGLOCATION NATIVE ?ENABLE | DISABLE Where appname and dbname are optional parameters giving you the chance in combination with the ENABLE or DISABLE command to set Transaction Logging for certain applications or databases or to exclude them from being logged. If only an appname is specified, the setting applies to all databases in that particular application. If appname and dbname are not defined, all applications and databases would be covered. LOGLOCATION specifies the directory to which the log is written, e.g. D:\temp\trlogs. This directory must already exist or needs to be created before using it for log information being written to it. NATIVE is a reserved keyword that shouldn’t be changed. The following example shows how to first enable logging on a more general level for all databases in the application Sample, followed by a disabling statement on a more granular level for only the Basic database in application Sample, hence excluding it from being logged. TRANSACTIONLOGLOCATION Sample Hyperion/trlog/Sample NATIVE ENABLE TRANSACTIONLOGLOCATION Sample Basic Hyperion/trlog/Sample NATIVE DISABLE Tip: After applying changes to the configuration file you must restart the Essbase server in order to initialize the settings. A maybe required replay of logged transactions after restoring a database can be done only by administrators. The following options are available: In Administration Services selecting Replay Transactions on the right-click menu on the database: Here you can select to replay transactions logged after the last replay request was originally executed or after the time of the last restored backup (whichever occurred later) or transactions logged after a specified time. Or you can replay transactions selectively based on a range of sequence IDs, which can be accessed using Display Transactions on the right-click menu on the database: These sequence ID s (0, 1, 2 … 7 in the screenshot below) are assigned to each logged transaction, indicating the order in which the transaction was performed. This helps to ensure the integrity of the restored data after a replay, as the replay of transactions is enforced in the same order in which they were originally performed. So for example a calculation originally run after a data load cannot be replayed before having replayed the data load first. After a transaction is replayed, you can replay only transactions with a greater sequence ID. For example, replaying the transaction with sequence ID of 4 includes all preceding transactions, while afterwards you can only replay transactions with a sequence ID of 5 or greater. Tip: After restoring a database from a backup you should always completely replay all logged transactions, which were executed after the backup, before executing new transactions. But not only the transaction information itself needs to be logged and stored in a specified directory as described above. During transaction logging, Essbase also creates archive copies of data load and rules files in the following default directory: ARBORPATH/app/appname/dbname/Replay These files are then used during the replay of a logged transaction. By default Essbase archives only data load and rules files for client data loads, but in order to specify the type of data to archive when logging transactions you can use the command TRANSACTIONLOGDATALOADARCHIVE as an additional entry in the Essbase.cfg file. The syntax for the statement is: TRANSACTIONLOGDATALOADARCHIVE [appname [dbname]] [OPTION] While to the [appname [dbname]] argument the same applies like before for TRANSACTIONLOGLOCATION, the valid values for the OPTION argument are the following: Make the respective setting for which files copies should be logged, considering from which location transactions are usually taking place. Selecting the NONE option prevents Essbase from saving the respective files and the data load cannot be replayed. In this case you must first manually load the data before you can replay the transactions. Tip: If you use server or SQL data and the data and rules files are not archived in the Replay directory (for example, you did not use the SERVER or SERVER_CLIENT option), Essbase replays the data that is actually in the data source at the moment of the replay, which may or may not be the data that was originally loaded. You can find more detailed information in the following documents: Oracle Hyperion Enterprise Performance Management System Backup and Recovery Guide (rel. 11.1.2.1) Oracle Essbase Online Documentation (rel. 11.1.2.1)) Enterprise Performance Management System Documentation (including previous releases) Or on the Oracle Technology Network. If you are also interested in other new features and smart enhancements in Essbase or Hyperion Planning stay tuned for coming articles or check our training courses and web presentations. You can find general information about offerings for the Essbase and Planning curriculum or other Oracle-Hyperion products here; (please make sure to select your country/region at the top of this page) or in the OU Learning paths section, where Planning, Essbase and other Hyperion products can be found under the Fusion Middleware heading (again, please select the right country/region). Or drop me a note directly: [email protected]. About the Author: Bernhard Kinkel started working for Hyperion Solutions as a Presales Consultant and Consultant in 1998 and moved to Hyperion Education Services in 1999. He joined Oracle University in 2007 where he is a Principal Education Consultant. Based on these many years of working with Hyperion products he has detailed product knowledge across several versions. He delivers both classroom and live virtual courses. His areas of expertise are Oracle/Hyperion Essbase, Oracle Hyperion Planning and Hyperion Web Analysis. Disclaimer: All methods and features mentioned in this article must be considered and tested carefully related to your environment, processes and requirements. As guidance please always refer to the available software documentation. This article does not recommend or advise any explicit action or change, hence the author cannot be held responsible for any consequences due to the use or implementation of these features.

    Read the article

  • Recording Topics manually and automatically

    - by maria.cozzolino(at)oracle.com
    When you are recording UPK topics, the default mode for recording is manual recording, where you tell the system when to record each screen shot. This mode allows you to take the exact screen shot you need. However, it does get a bit tedious when you are recording long topics, especially if you forget to take a few screen shots. In UPK 3.5, a new version of recording was introduced - Automatic Recording. It was designed to simplify the recording process by automatically capturing screen shots as you perform your transaction. If you haven't experimented with Automatic Recording, I'd recommend you give it a try - it might make your recording life easier. If you are recording with sound, you can also narrate your topic while recording it. To turn on Automatic Recording: 1. In Tools/Options, there are two recorder tabs. The first tab, under content defaults, includes settings that you may want to share between developers, like whether keyboard shortcuts are automatically captured. 2. The second tab is the one that contains the personal preferences, like screen shot capture key and whether to record automatically or manually. On this tab, choose the option for Automatic Recording. 3. Save the settings. Note that this setting will NOT impact content defaults; this is for your user only. When you launch the recorder, you will notice a slightly different message with guidance on how to start and stop automatic recording. Once you start recording, the recorder window is hidden until the end of the recording session to allow you to capture your transaction. In the task tray, there is a series of icons that let you know that you are capturing content. You can pause the recording, as well as set and view your sound levels if you are using sound. A camera appears during each screen capture to help you know when the system is capturing a screen shot, and a context indicator appears to show the recognition. With automatic recording, you can let the system capture the necessary screen shots. It may provide a more natural recording experience, and is probably easier for the untrained developer. On the other hand, you have a bit more control with manual recording on which screen shot appears, but it also means you have to remember to capture the screen shot. :) We'd be interested in hearing which type of recording you do, and any rationale on why you made that choice. Please comment and let us know. --Maria Cozzolino, Manager of UPK Software Requirements and UI Design

    Read the article

  • Find height of ContextMenuStrip before showing it

    - by Nailuj
    I have a ContextMenuStrip (ctMenuMassEdit) that I want to display when left-clicking a button (btnMassEdit). I want the ContextMenuStrip to be displayed above the button, i.e. position (0,-ContextMenuStrip.Height) relative to the button: private void btnMassEdit_Click(object sender, EventArgs e) { ctMenuMassEdit.Show(btnMassEdit, new Point(0, -ctMenuMassEdit.Height)); } However, the Height property is 0 the first time the button is clicked (I assume the ContextMenuStrip isn't created before it is shown the first time), and the result is that the ContextMenuStrip appears on top of the button. The 2nd time I click the button however, it appears in the correct position, so the basic of my logic is at least correct. I tried adding the following before showing the ContextMenuStrip, but it didn't work as hoped: if (!ctMenuMassEdit.Created) { ctMenuMassEdit.CreateControl(); } So, is there a way I can create the ContextMenuStrip before showing it the first time, so I have the correct Height property? I could of course use the hack of showing it, hiding it and showing it again, but that doesn't seem really neat...

    Read the article

  • Setting useLegacyV2RuntimeActivationPolicy At Runtime

    - by Reed
    Version 4.0 of the .NET Framework included a new CLR which is almost entirely backwards compatible with the 2.0 version of the CLR.  However, by default, mixed-mode assemblies targeting .NET 3.5sp1 and earlier will fail to load in a .NET 4 application.  Fixing this requires setting useLegacyV2RuntimeActivationPolicy in your app.Config for the application.  While there are many good reasons for this decision, there are times when this is extremely frustrating, especially when writing a library.  As such, there are (rare) times when it would be beneficial to set this in code, at runtime, as well as verify that it’s running correctly prior to receiving a FileLoadException. Typically, loading a pre-.NET 4 mixed mode assembly is handled simply by changing your app.Config file, and including the relevant attribute in the startup element: <?xml version="1.0" encoding="utf-8" ?> <configuration> <startup useLegacyV2RuntimeActivationPolicy="true"> <supportedRuntime version="v4.0"/> </startup> </configuration> .csharpcode { background-color: #ffffff; font-family: consolas, "Courier New", courier, monospace; color: black; font-size: small } .csharpcode pre { background-color: #ffffff; font-family: consolas, "Courier New", courier, monospace; color: black; font-size: small } .csharpcode pre { margin: 0em } .csharpcode .rem { color: #008000 } .csharpcode .kwrd { color: #0000ff } .csharpcode .str { color: #006080 } .csharpcode .op { color: #0000c0 } .csharpcode .preproc { color: #cc6633 } .csharpcode .asp { background-color: #ffff00 } .csharpcode .html { color: #800000 } .csharpcode .attr { color: #ff0000 } .csharpcode .alt { background-color: #f4f4f4; margin: 0em; width: 100% } .csharpcode .lnum { color: #606060 } This causes your application to run correctly, and load the older, mixed-mode assembly without issues. For full details on what’s happening here and why, I recommend reading Mark Miller’s detailed explanation of this attribute and the reasoning behind it. Before I show any code, let me say: I strongly recommend using the official approach of using app.config to set this policy. That being said, there are (rare) times when, for one reason or another, changing the application configuration file is less than ideal. While this is the supported approach to handling this issue, the CLR Hosting API includes a means of setting this programmatically via the ICLRRuntimeInfo interface.  Normally, this is used if you’re hosting the CLR in a native application in order to set this, at runtime, prior to loading the assemblies.  However, the F# Samples include a nice trick showing how to load this API and bind this policy, at runtime.  This was required in order to host the Managed DirectX API, which is built against an older version of the CLR. This is fairly easy to port to C#.  Instead of a direct port, I also added a little addition – by trapping the COM exception received if unable to bind (which will occur if the 2.0 CLR is already bound), I also allow a runtime check of whether this property was setup properly: public static class RuntimePolicyHelper { public static bool LegacyV2RuntimeEnabledSuccessfully { get; private set; } static RuntimePolicyHelper() { ICLRRuntimeInfo clrRuntimeInfo = (ICLRRuntimeInfo)RuntimeEnvironment.GetRuntimeInterfaceAsObject( Guid.Empty, typeof(ICLRRuntimeInfo).GUID); try { clrRuntimeInfo.BindAsLegacyV2Runtime(); LegacyV2RuntimeEnabledSuccessfully = true; } catch (COMException) { // This occurs with an HRESULT meaning // "A different runtime was already bound to the legacy CLR version 2 activation policy." LegacyV2RuntimeEnabledSuccessfully = false; } } [ComImport] [InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] [Guid("BD39D1D2-BA2F-486A-89B0-B4B0CB466891")] private interface ICLRRuntimeInfo { void xGetVersionString(); void xGetRuntimeDirectory(); void xIsLoaded(); void xIsLoadable(); void xLoadErrorString(); void xLoadLibrary(); void xGetProcAddress(); void xGetInterface(); void xSetDefaultStartupFlags(); void xGetDefaultStartupFlags(); [MethodImpl(MethodImplOptions.InternalCall, MethodCodeType = MethodCodeType.Runtime)] void BindAsLegacyV2Runtime(); } } Using this, it’s possible to not only set this at runtime, but also verify, prior to loading your mixed mode assembly, whether this will succeed. In my case, this was quite useful – I am working on a library purely for internal use which uses a numerical package that is supplied with both a completely managed as well as a native solver.  The native solver uses a CLR 2 mixed-mode assembly, but is dramatically faster than the pure managed approach.  By checking RuntimePolicyHelper.LegacyV2RuntimeEnabledSuccessfully at runtime, I can decide whether to enable the native solver, and only do so if I successfully bound this policy. There are some tricks required here – To enable this sort of fallback behavior, you must make these checks in a type that doesn’t cause the mixed mode assembly to be loaded.  In my case, this forced me to encapsulate the library I was using entirely in a separate class, perform the check, then pass through the required calls to that class.  Otherwise, the library will load before the hosting process gets enabled, which in turn will fail. This code will also, of course, try to enable the runtime policy before the first time you use this class – which typically means just before the first time you check the boolean value.  As a result, checking this early on in the application is more likely to allow it to work. Finally, if you’re using a library, this has to be called prior to the 2.0 CLR loading.  This will cause it to fail if you try to use it to enable this policy in a plugin for most third party applications that don’t have their app.config setup properly, as they will likely have already loaded the 2.0 runtime. As an example, take a simple audio player.  The code below shows how this can be used to properly, at runtime, only use the “native” API if this will succeed, and fallback (or raise a nicer exception) if this will fail: public class AudioPlayer { private IAudioEngine audioEngine; public AudioPlayer() { if (RuntimePolicyHelper.LegacyV2RuntimeEnabledSuccessfully) { // This will load a CLR 2 mixed mode assembly this.audioEngine = new AudioEngineNative(); } else { this.audioEngine = new AudioEngineManaged(); } } public void Play(string filename) { this.audioEngine.Play(filename); } } Now – the warning: This approach works, but I would be very hesitant to use it in public facing production code, especially for anything other than initializing your own application.  While this should work in a library, using it has a very nasty side effect: you change the runtime policy of the executing application in a way that is very hidden and non-obvious.

    Read the article

  • Ubuntu 10.10 Network Issues (wireless as well as wired)

    - by user9054
    down vote favorite Hi Friends, I have got this issue with Ubuntu 10.10 . I have been with ubuntu 8.04 and then decided to try out ubuntu 10.10 . I booted with a LiveCD and was able to configure the wireless network painlessly using the livecd . so happily i installed ubuntu 10.10 . As soon as ubuntu came up it detected the wireless network and i was able to assign a static IP to eth1 (i dont use DHCP option on my ADSL router) and enter a wap key and use pppoeconf to configure the dialer . The net was on and i was able to surf the net . all hunky dory so far . However on the next boot the fun started . It did not detect the wireless network . I could not see the network manager icon in the systray . I used ifconfig and saw that the entry for eth1 was missing .I used ifup eth1 and it said that eth1 was already up . Then i installed wifi-radar . Wifi-Radar detected the wireless network . I configured wifi-radar for the detected wireless network , set the wap driver as wext and used the manual IP settings . However on clicking connect wifi-radar started looking for a DHCP IP , needless to say it failed . For the love of god i cannot understand why wifi-radar is using DHCP when i have specified manual settings . Next i decided to use the wired network to surf the net looking for a solution . So i plugged in the network cable from my modem , it detected the plugged in connection , i configured eth0 , used pppoeconf and connected to the net . Then i foolishly decided to reboot my PC . And wonders of wonders , the same problem appeared . I cannot see eth0 in my ifconfig anymore . i used pon to start the dsl-provider connection and it said something about network error or something . Now my ifconfig shows only lo , both eth0 and eth1 have disappeared .Can anybody help me on this ? Is it a problem with ipv6 , if so how do you disable ipv6 on ubuntu 10.10 ? OR is this is a known issue with ubuntu 10.10 ? .PS : 1) i tried linux mint 10 and had the same issue . on rebooting wireless network was not getting detected . 2) i have made myself the administrator so that there is no issue of rights or anything. Any help is appreciated.

    Read the article

  • 5 Best Practices - Laying the Foundation for WebCenter Projects

    - by Kellsey Ruppel
    Today’s guest post comes from Oracle WebCenter expert John Brunswick. John specializes in enterprise portal and content management solutions and actively contributes to the enterprise software business community and has authored a series of articles about optimal business involvement in portal, business process management and SOA development, examining ways of helping organizations move away from monolithic application development. We’re happy to have John join us today! Maximizing success with Oracle WebCenter portal requires a strategic understanding of Oracle WebCenter capabilities.  The following best practices enable the creation of portal solutions with minimal resource overhead, while offering the greatest flexibility for progressive elaboration. They are inherently project agnostic, enabling a strong foundation for future growth and an expedient return on your investment in the platform.  If you are able to embrace even only a few of these practices, you will materially improve your deployment capability with WebCenter. 1. Segment Duties Around 3Cs - Content, Collaboration and Contextual Data "Agility" is one of the most common business benefits touted by modern web platforms.  It sounds good - who doesn't want to be Agile, right?  How exactly IT organizations go about supplying agility to their business counterparts often lacks definition - hamstrung by ambiguity. Ultimately, businesses want to benefit from reduced development time to deliver a solution to a particular constituent, which is augmented by as much self-service as possible to develop and manage the solution directly. All done in the absence of direct IT involvement. With Oracle WebCenter's depth in the areas of content management, pallet of native collaborative services, enterprise mashup capability and delegated administration, it is very possible to execute on this business vision at a technical level. To realize the benefits of the platform depth we can think of Oracle WebCenter's segmentation of duties along the lines of the 3 Cs - Content, Collaboration and Contextual Data.  All three of which can have their foundations developed by IT, then provisioned to the business on a per role basis. Content – Oracle WebCenter benefits from an extremely mature content repository.  Work flow, audit, notification, office integration and conversion capabilities for documents (HTML & PDF) make this a haven for business users to take control of content within external and internal portals, custom applications and web sites.  When deploying WebCenter portal take time to think of areas in which IT can provide the "harness" for content to reside, then allow the business to manage any content items within the site, using the content foundation to ensure compliance with business rules and process.  This frees IT to work on more mission critical challenges and allows the business to respond in short order to emerging market needs. Collaboration – Native collaborative services and WebCenter spaces are a perfect match for business users who are looking to enable document sharing, discussions and social networking.  The ability to deploy the services is granular and on the basis of roles scoped to given areas of the system - much like the first C “content”.  This enables business analysts to design the roles required and IT to provision with peace of mind that users leveraging the collaborative services are only able to do so in explicitly designated areas of a site. Bottom line - business will not need to wait for IT, but cannot go outside of the scope that has been defined based on their roles. Contextual Data – Collaborative capabilities are most powerful when included within the context of business data.  The ability to supply business users with decision shaping data that they can include in various parts of a portal or portals, just as they would with content items, is one of the most powerful aspects of Oracle WebCenter.  Imagine a discussion about new store selection for a retail chain that re-purposes existing information from business intelligence services about various potential locations and or custom backend systems - presenting it directly in the context of the discussion.  If there are some data sources that are preexisting in your enterprise take a look at how they can be made into discrete offerings within the portal, then scoped to given business user roles for inclusion within collaborative activities. 2. Think Generically, Execute Specifically Constructs.  Anyone who has spent much time around me knows that I am obsessed with this word.  Why? Because Constructs offer immense power - more than APIs, Web Services or other technical capability. Constructs offer organizations the ability to leverage a platform's native characteristics to offer substantial business functionality - without writing code.  This concept becomes more powerful with the additional understanding of the concepts from the platform that an organization learns over time.  Let's take a look at an example of where an Oracle WebCenter construct can substantially reduce the time to get a subscription-based site out the door and into the hands of the end consumer. Imagine a site that allows members to subscribe to specific disciplines to access information and application data around that various discipline.  A space is a collection of secured pages within Oracle WebCenter.  Spaces are not only secured, but also default content stored within it to be scoped automatically to that space. Taking this a step further, Oracle WebCenter’s Activity Stream surfaces events, discussions and other activities that are scoped to the given user on the basis of their space affiliations.  In order to have a portal that would allow users to "subscribe" to information around various disciplines - spaces could be used out of the box to achieve this capability and without using any APIs or low level technical work to achieve this. 3. Make Governance Work for You Imagine driving down the street without the painted lines on the road.  The rules of the road are so ingrained in our minds, we often do not think about the process, but seemingly mundane lane markers are critical enablers. Lane markers allow us to travel at speeds that would be impossible if not for the agreed upon direction of flow. Additionally and more importantly, it allows people to act autonomously - going where they please at any given time. The return on the investment for mobility is high enough for people to buy into globally agreed up governance processes. In Oracle WebCenter we can use similar enablers to lane markers.  Our goal should be to enable the flow of information and provide end users with the ability to arrive at business solutions as needed, not on the basis of cumbersome processes that cannot meet the business needs in a timely fashion. How do we do this? Just as with "Segmentation of Duties" Oracle WebCenter technologies offer the opportunity to compartmentalize various business initiatives from each other within the system due to constructs and security that are available to use within the platform. For instance, when a WebCenter space is created, any content added within that space by default will be secured to that particular space and inherits meta data that is associated with a folder created for the space. Oracle WebCenter content uses meta data to support a broad range of rich ECM functionality and can automatically impart retention, workflow and other policies automatically on the basis of what has been defaulted for that space. Depending on your business needs, this paradigm will also extend to sub sections of a space, offering some interesting possibilities to enable automated management around content. An example may be press releases within a particular area of an extranet that require a five year retention period and need to the reviewed by marketing and legal before release.  The underlying content system will transparently take care of this process on the basis of the above rules, enabling peace of mind over unstructured data - which could otherwise become overwhelming. 4. Make Your First Project Your Second Imagine if Michael Phelps was competing in a swimming championship, but told right before his race that he had to use a brand new stroke.  There is no doubt that Michael is an outstanding swimmer, but chances are that he would like to have some time to get acquainted with the new stroke. New technologies should not be treated any differently.  Before jumping into the deep end it helps to take time to get to know the new approach - even though you may have been swimming thousands of times before. To quickly get a handle on Oracle WebCenter capabilities it can be helpful to deploy a sandbox for the team to use to share project documents, discussions and announcements in an effort to help the actual deployment get under way, while increasing everyone’s knowledge of the platform and its functionality that may be helpful down the road. Oracle Technology Network has made a pre-configured virtual machine available for download that can be a great starting point for this exercise. 5. Get to Know the Community If you are reading this blog post you have most certainly faced a software decision or challenge that was solved on the basis of a small piece of missing critical information - which took substantial research to discover.  Chances were also good that somewhere, someone had already come across this information and would have been excited to share it. There is no denying the power of passionate, connected users, sharing key tips around technology.  The Oracle WebCenter brand has a rich heritage that includes industry-leading technology and practitioners.  With the new Oracle WebCenter brand, opportunities to connect with these experts has become easier. Oracle WebCenter Blog Oracle Social Enterprise LinkedIn WebCenter Group Oracle WebCenter Twitter Oracle WebCenter Facebook Oracle User Groups Additionally, there are various Oracle WebCenter related blogs by an excellent grouping of services partners.

    Read the article

  • Restore Gene : Automating SQL Server Database Restores

    Restore Gene is a simple 2-script framework, one PowerShell script and one SQL stored procedure, which will speed up the production of restore scripts for manual disaster recovery, as well help automate log shipping. FREE eBook – "45 Database Performance Tips for Developers"Improve your database performance with 45 tips from SQL Server MVPs and industry experts. Get the eBook here.

    Read the article

< Previous Page | 110 111 112 113 114 115 116 117 118 119 120 121  | Next Page >