Search Results

Search found 14383 results on 576 pages for 'double checked locking'.

Page 12/576 | < Previous Page | 8 9 10 11 12 13 14 15 16 17 18 19  | Next Page >

  • Using CompareTo() on different .NET types (e.g. int vs. double)

    - by Yossin
    Hi, I've got a static method that accepts two object type variables and runs the CompareTo() method: public static int Compare(Object objA, Object objB) { return (((IComparable)objA).CompareTo(objB)); } Problem is that CompareTo() throws an exception when trying to compare between different types (e.g. int and double). Does any one know of a better way in C#, to compare between two different types? Or a workaround to this problem? Thanks

    Read the article

  • Desktop switcher appears to be broken for quick double-switches

    - by Jon Blackburn
    I'm wondering if anyone else has seen this. I have three virtual desktops aligned in a horizontal row. In the middle desktop I have only a single application window. I have keyboard shortcuts mapping to navigate between the desktops. Obviously, I never use the up/down arrows because I only have one row of workspaces. Here's the problem, which only started to happen after I installed 12.04.1: When I rapidly hit to go from workspace 1 to workspace 3, the window on workspace 2 gets moved to workspace 1. I have checked using both Unity and Gnome3, and the behavior is the same under both. If I change back to the default workspace setup (a 2x2 grid of desktops) things seem to settle down (i.e., no wandering windows). Not every type of application window behaves the same way. I couldn't get a Chrome browser to jump from 2 to 1, but both Terminal and Terminator exhibit the behavior. Any thoughts? Better workarounds? Thanks in advance.

    Read the article

  • Open the LOV of af:inputListOfValues with a double click

    - by frank.nimphius
    To open the LOV popup of an af:inputListOfValues component in ADF Faces, you either click the magnifier icon to the right of the input field or tab onto the icon and press the Enter key. If you want to open the same dialog in response to a user double click into the LOV input field, JavaScript is a friend. For this solution, I assume you created an editable table or input form that is based on a View Object that contains at least one attribute that has a model driven list of values defined. The Default List Type is should be set to Input Text with List of Values so that when the form or table gets created, the attribute is rendered by the af:inputListOfValues component. To implement the use case, drag a Client Listener component from the Operations accordion in the Component Palette and drop it onto the af:inputListOfValues component in the page. In the opened Insert Client Listener dialog, define the Method as handleLovOnDblclickand choose dblClick in the select list for the Type attribute. Add the following code snippet to the page source directly below the af:document tag. <af:document id="d1">      <af:resource type="javascript">     function handleLovOnDblclick(evt){             var lovComp = evt.getSource();             if (lovComp instanceof AdfRichInputListOfValues &&          lovComp.getReadOnly()==false){           AdfLaunchPopupEvent.queue(lovComp,true);        }     }      </af:resource> The JavaScript function is called whenever the user clicks into the LOV field. It gets the source component reference from the event object that is passed into the function and verifies the LOV component is not read only. It then queues the launch event for the LOV popup to open. The page source for the LOV component is shown below: <af:inputListOfValues id="departmentIdId" … >   <f:validator binding="…"/>   …  <af:clientListener method="handleLovOnDblclick" type="dblClick"/> </af:inputListOfValues>

    Read the article

  • GAC locking problem when running deployment

    - by Kieran
    We have a NANT script that uses msbuild to compile our visual studio solutions and deploys the .dlls into the GAC. This works well on our integration/test servers as part of continuous integration, cruise control uses the NANT scripts and every time the dlls are put into the GAC without problem. On our local development machines, where we use subversion/vs.net etc. for development, frequently certain dlls do not make it to the GAC when we run the build. We think we have narrowed this down to visual studio and/or a plug in locking the GAC or the dlls for some reason. Strangely if we run the build a second time all the dlls make it to the GAC. We have added various iisreset's to the NANT script in the hope of releasing the lock but to no avail. Can anyone suggest a good approach to attack this problem? All the best

    Read the article

  • SLES 11 - ocfs2 - Locking does not appear to work

    - by Autobyte
    Hi I have two SLES 11 servers that are SAN attached to a Clarion CX-340. The SAN partition has been formatted with ocfs2 and I have both machines setup in a cluster and the cluster is running (all appears to be normal). I have a small java application as a locking test and when I run the application on both machines at the same time, I should get the lock on one server and the other should refuse the lock since the first already holds a lock on that file but in this case both servers get a lock on the same file. Basically my cluster.conf looks like this: node: ip_port = 7777 ip_address = 192.168.10.121 number = 1 name = osrsles10node1 cluster = osrsles10 node: ip_port = 7777 ip_address = 192.168.10.122 number = 2 name = osrsles10node2 cluster = osrsles10 cluster: node_count = 2 name = osrsles10 Please ask for any other info - I really need these locks to be exclusive to each server. Thanks.

    Read the article

  • How safe is locking the screen?

    - by D Connors
    So, both windows and linux have a pretty useful feature that allows you to leave everything running on the PC while also keeping invaders away by locking the screen. My question is: Say I leave my laptop with the screen locked while I go get a donnut, and then it gets stolen. Assuming the thief has access to whatever software he needs, how easy/hard would it be for him to access my (currently logged-in) account? Now let me be clear. I'm not asking if he can access the data on the harddrive. I know he can, and that issue would go under data encryption, which is not my question here. I'm focusing on how hard would it be to get around the "Insert Password" screen, and have full access to my account. I'm looking for answers regarding both OS's; but, if needed, assume Ubuntu. Thank you.

    Read the article

  • Windows 7 Locking up Randomly

    - by Michael Moore
    I've got a Windows 7 machine that is locking up randomly. It can be in the first thirty seconds, or it can be hours later. There is nothing specific I can find that is running when it happens. When it locks, the screen doesn't change, but nothing moves. The waiting icon stops, the mouse stops, keyboard doesn't work, etc. I've even tried the crash on ctrl-scrl registry hack, and it won't even dump the kernel. I've run hardware diagnostics on the RAM and it doesn't find any problems. I would think it is a hardware issue, but on this exact same machine, I can run 64 Bit Ubuntu and it has zero problems. I've even tried reinstalling Windows7 from scratch, and it still happens. Anyone have any ideas? Any good diagnostic tools to recommend? Thanks! Michael

    Read the article

  • Locking down remote desktop using AD GPO

    - by Brettski
    I am currently locking down a companies remote desktop access via a VPN. What I need to do is disable remote printing, file transfer and clipboard via active directory for the workstations that will be accessed. I am having trouble figuring out which GPO's are used to restrict this. My basic approach is to restrict VPN users to port 3389 so the will be able to access their work computers remotely but nothing else (I will look into layer 7 scanning later). With this I want to ensure they are unable to transfer and data via files, printing or the clipboard. The environment is Windows Server 2003

    Read the article

  • MySQLDump without locking the tables

    - by Raul Singahn
    It seems that if you have many tables, you can only perform a MySQLDump without locking them all, otherwise you can an error. What are the side effects of performing a MySQLDump without locking all the tables; Is the DB snapshot I get this way, consistent? Do I have any other alternative for getting a backup of a MySQL DB with many tables?

    Read the article

  • Precision of cos(atan2(y,x)) versus using complex <double>, C++

    - by Ivan
    Hi all, I'm writing some coordinate transformations (more specifically the Joukoswky Transform, Wikipedia Joukowsky Transform), and I'm interested in performance, but of course precision. I'm trying to do the coordinate transformations in two ways: 1) Calculating the real and complex parts in separate, using double precision, as below: double r2 = chi.x*chi.x + chi.y*chi.y; //double sq = pow(r2,-0.5*n) + pow(r2,0.5*n); //slow!!! double sq = sqrt(r2); //way faster! double co = cos(atan2(chi.y,chi.x)); double si = sin(atan2(chi.y,chi.x)); Z.x = 0.5*(co*sq + co/sq); Z.y = 0.5*si*sq; where chi and Z are simple structures with double x and y as members. 2) Using complex : Z = 0.5 * (chi + (1.0 / chi)); Where Z and chi are complex . There interesting part is that indeed the case 1) is faster (about 20%), but the precision is bad, giving error in the third decimal number after the comma after the inverse transform, while the complex gives back the exact number. So, the problem is on the cos(atan2), sin(atan2)? But if it is, how the complex handles that? Thanks!

    Read the article

  • [Netbeans 6.9] Java MethodOverloading error with double values

    - by Nimitips
    Here is a part of my code I'm having trouble with: ===Class Overload=== public class Overload { public void testOverLoadeds() { System.out.printf("Square of integer 7 is %d\n",square(7)); System.out.printf("Square of double 7.5 is %d\n",square(7.5)); }//..end testOverloadeds public int square(int intValue) { System.out. printf("\nCalled square with int argument: %d\n",intValue); return intValue * intValue; }//..end square int public double square(double doubleValue) { System.out.printf("\nCalled square with double argument: %d\n", doubleValue); return doubleValue * doubleValue; }//..end square double }//..end class overload ===Main=== public static void main(String[] args) { Overload methodOverload = new Overload(); methodOverload.testOverLoadeds(); } It compiles with no error, however when I try to run it the output is: Called square with int argument: 7 Square of integer 7 is 49 Exception in thread "main" java.util.IllegalFormatConversionException: d != java.lang.Double at java.util.Formatter$FormatSpecifier.failConversion(Formatter.java:3999) at java.util.Formatter$FormatSpecifier.printInteger(Formatter.java:2709) at java.util.Formatter$FormatSpecifier.print(Formatter.java:2661) at java.util.Formatter.format(Formatter.java:2433) at java.io.PrintStream.format(PrintStream.java:920) at java.io.PrintStream.printf(PrintStream.java:821) at methodoverload.Overload.square(Overload.java:19) at methodoverload.Overload.testOverLoadeds(Overload.java:8) at methodoverload.Main.main(Main.java:9) Called square with double argument:Java Result: 1 What am I doing wrong? I'm on Ubuntu 10.10, Netbeans 6.9. Thanks.

    Read the article

  • Computer keeps locking me out

    - by me32
    When I'm away from my computer (Windows XP) for more than ~30 minutes, I get locked out, and have to press Ctrl+Alt+Delete to login. I've checked the screensaver settings, and it's not set to lock the screen. Does anyone know what else could be causing this? Thanks

    Read the article

  • Mistake in display and insert methods (double-ended queue)

    - by MANAL
    1) My problem when i make remove from right or left program will be remove true but when i call diplay method the content wrong like this I insert 12 43 65 23 and when make remove from left program will remove 12 but when call display method show like this 12 43 65 and when make remove from right program will remove 23 but when call display method show like this 12 43 Why ?????? ); and when i try to make insert after remove write this Can not insert right because the queue is full . first remove right and then u can insert right where is the problem ?? Please Help me please 2) My code FIRST CLASS class dqueue { private int fullsize; //number of all cells private int item_num; // number of busy cells only private int front,rear; public int j; private double [] dqarr; //========================================== public dqueue(int s) //constructor { fullsize = s; front = 0; rear = -1; item_num = 0; dqarr = new double[fullsize]; } //========================================== public void insert(double data) { if (rear == fullsize-1) rear = -1; rear++; dqarr[rear] = data; item_num++; } public double removeLeft() // take item from front of queue { double temp = dqarr[front++]; // get value and incr front if(front == fullsize) front = 0; item_num --; // one less item return temp; } public double removeRight() // take item from rear of queue { double temp = dqarr[rear--]; // get value and decr rear if(rear == -1) // rear = item_num -1; item_num --; // one less item return temp; } //========================================= public void display () //display items { for (int j=0;j<item_num;j++) // for every element System.out.print(dqarr[j] +" " ); // display it System.out.println(""); } //========================================= public int size() //number of items in queue { return item_num; } //========================================== public boolean isEmpty() // true if queue is empty { return (item_num ==0); } } SECOND CLASS import java.util.Scanner; class dqueuetest { public static void main(String[] args) { Scanner input = new Scanner(System.in); System.out.println(" ***** Welcome here***** "); System.out.println(" ***** Mind Of Programming Group***** "); System.out.println(" _____________________________________________ "); System.out.println("enter size of your dqueue"); int size = input.nextInt(); dqueue mydq = new dqueue(size); System.out.println(""); System.out.println("enter your itemes"); //===================================== for(int i = 0;i<=size-1;i++) { System.out.printf("item %d:",i+1); double item = input.nextDouble(); mydq.insert(item); System.out.println(""); } //===================================== int queue =size ; int c = 0 ; while (c != 6) { System.out.println(""); System.out.println("************************************************"); System.out.println(" MAIN MENUE"); System.out.println("1- INSERT RIGHT "); System.out.println("2- REMOVE LEFT"); System.out.println("3- REMOVE RIGHT"); System.out.println("4- DISPLAY"); System.out.println("5- SIZE"); System.out.println("6- EXIT"); System.out.println("************************************************"); System.out.println("choose your operation by number(1-6)"); c = input.nextInt(); switch (c) { case 1: if (queue == size) System.out.print("Can not insert right because the queue is full . first remove right and then u can insert right "); else { System.out.print("enter your item: "); double item = input.nextDouble(); mydq.insert(item);} break; case 2: System.out.println("REMOVE FROM REAR :"); if( !mydq.isEmpty() ) { double item = mydq.removeLeft(); System.out.print(item + "\t"); } // end while System.out.println(""); mydq.display(); break; case 3: System.out.println("REMOVE FROM FRONT :"); if( !mydq.isEmpty() ) { double item = mydq.removeRight(); System.out.print(item + "\t"); } // end while System.out.println(""); mydq.display(); break; case 4: System.out.println("The items in Queue are :"); mydq.display(); break; case 5: System.out.println("The Size of the Queue is :"+mydq.size()); break; case 6: System.out.println("Good Bye"); break; default: System.out.println("wrong chiose enter again"); } //end switch } //end while } // end main }//end class

    Read the article

  • Mistake in dispaly and insert method (double - ended queue)

    - by MANAL
    1) My problem when i make remove from right or left program will be remove true but when i call diplay method the content wrong like this I insert 12 43 65 23 and when make remove from left program will remove 12 but when call display method show like this 12 43 65 and when make remove from right program will remove 23 but when call display method show like this 12 43 Why ?????? ); and when i try to make insert after remove write this Can not insert right because the queue is full . first remove right and then u can insert right where is the problem ?? Please Help me please 2) My code FIRST CLASS class dqueue { private int fullsize; //number of all cells private int item_num; // number of busy cells only private int front,rear; public int j; private double [] dqarr; //========================================== public dqueue(int s) //constructor { fullsize = s; front = 0; rear = -1; item_num = 0; dqarr = new double[fullsize]; } //========================================== public void insert(double data) { if (rear == fullsize-1) rear = -1; rear++; dqarr[rear] = data; item_num++; } public double removeLeft() // take item from front of queue { double temp = dqarr[front++]; // get value and incr front if(front == fullsize) front = 0; item_num --; // one less item return temp; } public double removeRight() // take item from rear of queue { double temp = dqarr[rear--]; // get value and decr rear if(rear == -1) // rear = item_num -1; item_num --; // one less item return temp; } //========================================= public void display () //display items { for (int j=0;j //========================================= public int size() //number of items in queue { return item_num; } //========================================== public boolean isEmpty() // true if queue is empty { return (item_num ==0); } } SECOND CLASS import java.util.Scanner; class dqueuetest { public static void main(String[] args) { Scanner input = new Scanner(System.in); System.out.println(" Welcome here** "); System.out.println(" * Mind Of Programming Group*** "); System.out.println(" _________________________ "); System.out.println("enter size of your dqueue"); int size = input.nextInt(); dqueue mydq = new dqueue(size); System.out.println(""); System.out.println("enter your itemes"); //===================================== for(int i = 0;i<=size-1;i++) { System.out.printf("item %d:",i+1); double item = input.nextDouble(); mydq.insert(item); System.out.println(""); } //===================================== int queue =size ; int c = 0 ; while (c != 6) { System.out.println(""); System.out.println("**************************"); System.out.println(" MAIN MENUE"); System.out.println("1- INSERT RIGHT "); System.out.println("2- REMOVE LEFT"); System.out.println("3- REMOVE RIGHT"); System.out.println("4- DISPLAY"); System.out.println("5- SIZE"); System.out.println("6- EXIT"); System.out.println("**************************"); System.out.println("choose your operation by number(1-6)"); c = input.nextInt(); switch (c) { case 1: if (queue == size) System.out.print("Can not insert right because the queue is full . first remove right and then u can insert right "); else { System.out.print("enter your item: "); double item = input.nextDouble(); mydq.insert(item);} break; case 2: System.out.println("REMOVE FROM REAR :"); if( !mydq.isEmpty() ) { double item = mydq.removeLeft(); System.out.print(item + "\t"); } // end while System.out.println(""); mydq.display(); break; case 3: System.out.println("REMOVE FROM FRONT :"); if( !mydq.isEmpty() ) { double item = mydq.removeRight(); System.out.print(item + "\t"); } // end while System.out.println(""); mydq.display(); break; case 4: System.out.println("The items in Queue are :"); mydq.display(); break; case 5: System.out.println("The Size of the Queue is :"+mydq.size()); break; case 6: System.out.println("Good Bye"); break; default: System.out.println("wrong chiose enter again"); } //end switch } //end while } // end main }//end class

    Read the article

  • WinForms (C#) Databinding Object to Checkbox.Checked Property

    - by Trevor Sullivan
    Hello, I'm writing a WinForms app, and am trying to bind a boolean property on a .NET object to a Checkbox's "checked" property. I am successfully creating the binding, but when I change the source property's value from false to true (I have a button that toggles it), the checkbox's "checked" property does not reflect that change. if (chkPreRun.DataBindings["Checked"] == null) { Debug.WriteLine("Adding chkPreRun databinding"); Binding _binding = chkPreRun.DataBindings.Add("Checked", NwmConfig, "PreRun") // Added this just to ensure that these were being set properly _binding.DataSourceUpdateMode = DataSourceUpdateMode.OnPropertyChanged; _binding.ControlUpdateMode = ControlUpdateMode.OnPropertyChanged; } I am able to successfully bind the text property to the value of a TextBox, for example. I'm not sure what I'm missing while binding to the "Checked" property, however. Cheers, Trevor

    Read the article

  • Change Check Out Folder for checked out files in SourceSafe

    - by Town
    I had to rebuild my machine and went from XP to Windows 7. I've now got a bit of an issue: I had files checked out in SourceSafe previously, which I still have copies of in the local folder on my new install. However, SourceSafe still has them checked out to the old XP folder (c:\documents and settings etc) whereas the files now reside in c:\Users. Pending Checkins in Visual Studio now thinks I have nothing checked out, and SourceSafe declares that the files are checked out to me under the c:\documents and settings\ path. Is there any way to tell SourceSafe to simply "look over there" for the files instead? It seems to work with individually undoing and redoing checkout on the files, but that's a lengthy process and one I'd like to avoid if possible. If I simply checkout the files individually then it lists them as checked out to me twice, one for each of the locations. Any pointers would be very much appreciated!

    Read the article

  • jquery checked checkbox IE problem

    - by lidermin
    Hi, I'm having an issue verifying if a checkbox is checked using jquery on Internet Explorer. This is the code I'm using: if ($('#chkjq_1').attr('checked') == true) It works fine on Firefox or Chrome, but on Internet Explorer 7, the condition is always false because the browser sets the property this way: <input id="chkjq_1" type="checkbox" CHECKED/> IE7 And the right way is the following: (Firefox, Chrome): <input id="chkjq_1" type="checkbox" checked="checked"/> FF, Chrome, etc What should I do to avoid this issue on Internet Explorer 7; is there a generic way in jquery to solve this? Thanks in advance.

    Read the article

  • jQuery if checkbox is checked to toggle classes

    - by Lynx
    I am needed to change my jQuery code up. Instead of the label toggling the class and showing the icon I need it to where if the checkbox is checked to show to toggle those classes. I have tried prop and is but I couldn't get them to work properly. The reason for the change is I want to preload data into the form and if it's going to be checked those toggles need to reflect that change. http://jsfiddle.net/70fbLooL/2/ EDIT Seems to be confusion as to exactly what I am trying to do. The fiddle I provided works perfectly fine. The problem is if I want to call the form from server-side and pre-populate the form the checkbox toggles will not show that they are checked because it's based on the clicked function. I need it to be based on if the checkbox equal true or checked. That way if the value equals true from the server-side call it will toggle those classes and look like it's checked.

    Read the article

  • Compaq R4000 laptop randomly locking up

    - by Josh
    I have a Compaq R4000 laptop with 2GB of RAM, running Ubuntu Linux 9.10. It is randomly locking up on me, approximately once every two days. I have a second partition with Windows XP Home installed, and I have had the system lock up in XP as well, meaning I believe this is a hardware issue. I have run two passes of Memtest86+ with no errors. The system has a fan that has died, so I initially suspected overheating. However the system just locked up on me while I was in the middle of typing a script to warn me / shut down if the temperature was too high. When the lockup happened the temperature was 88°F, so I am now starting to believe that may not be the issue. When the system locks up, I cannot SSH in nor ping it. Nothing shows in syslog when I reboot. I have configured it to send syslog messages to a local server as well and no messages appear on that server when the lockup happens. I am open to any and all advice!

    Read the article

  • Make a snapshot of a live mySQL database with myISAM & innoDB tables without locking

    - by Artem
    We have a live database in production where we are running out of space on the server. So I would like to transfer to a new server without any downtime (or as little downtime as possible). In general, I would also like to have a hot failover copy of the database available. I would like to use replication to get all of the data copied to the new machine, and then at some point flip a switch and have that new machine become the master (normal failover scenario). My problem is that I am not sure how to initialize replication without locking the db to make the initial snapshot I will use? Is there any way to do this? I know I could do it using single-transaction if I was using innoDB, but very unfortunately we have some myISAM tables in there (in fact the largest 150GB table is myISAM and I want to switch it to InnoDB but I can't do it until I have more space & a hot copy to switch to). Any ideas? Is there some way to make such a snapshot? Or is there alternatively a way to get replication to "catch up" without an snapshot for initialization?

    Read the article

  • SQL Server Read Locking behavior

    - by Charles Bretana
    When SQL Server Books online says that "Shared (S) locks on a resource are released as soon as the read operation completes, unless the transaction isolation level is set to repeatable read or higher, or a locking hint is used to retain the shared (S) locks for the duration of the transaction." Assuming we're talking about a row-level lock, with no explicit transaction, at default isolation level (Read Committed), what does "read operation" refer to? The reading of a single row of data? The reading of a single 8k IO Page ? or until the the complete Select statement in which the lock was created has finished executing, no matter how many other rows are involved? NOTE: The reason I need to know this is we have a several second read-only select statement generated by a data layer web service, which creates page-level shared read locks, generating a deadlock due to conflicting with row-level exclusive update locks from a replication prcoess that keeps the server updated. The select statement is fairly large, with many sub-selects, and one DBA is proposing that we rewrite it to break it up into multiple smaller statements (shorter running pieces), "to cut down on how long the locks are held". As this assumes that the shared read locks are held till the complete select statement has finished, if that is wrong (if locks are released when the row, or the page is read) then that approach would have no effect whatsoever....

    Read the article

< Previous Page | 8 9 10 11 12 13 14 15 16 17 18 19  | Next Page >