Search Results

Search found 6674 results on 267 pages for 'signal handling'.

Page 12/267 | < Previous Page | 8 9 10 11 12 13 14 15 16 17 18 19  | Next Page >

  • MBPro, mid 2010 can't see Dlink DIR655 signal after sleep etc

    - by user88114
    This is my son's MBP 7,1 running Snow Leopard 10.6.7. Router signal is fine since iPad, Wintel on same table 20 feet from router are fine. the MBP however frequently wakes and fails to find the internet. iStumbler can see 1 neighbours hub and my garden hub are there but can't get to the normal DIR655 wifi... no ping no en0 or en1 device seems to exist. Airport off and on does not help. He just resets router and it all works but this does not please me! I must admit the winter sometimes seems to loose connect too, but less so. The DIR655 (hardware rev A3) is on the original EU firmware 1.10, I'm cautious about jumping to latest 1.31EU since no downgrade seems to be possible and that feels a bit risky as so much is set up and working fine. If I use the DIR655 admin web and release the lease the MBP has then wake it all worked OK. So I suspect lease timing/locking issue but unsure how to check up, plus why iStumbler seems to say the network is not visible at all when I sit on the iPad right next to it just fine.. I do not think there are any channel overlaps and we also have RFquiet DECT phones (Orchid) that are silent until lifted or called. Anyway signals all show low interference and high throughput except for this failure to connect. Just walked the MBP to the garden office and iStumbler now sees the more distant DIR655 signal although it will not connect to it (does not show under Sys Prefs NetNetwork names) even after airport off & on... It also refuses to connect to my garden network (an old Belkin acting as AP wired to DIR655), the signal it can see and even net name in Sys Prefs NetNetwork names (2 mins later):NOW both names ARE visible, but both fail to accept the correct WPA2 password and keep asking again after failing to connect. IT ALL MAKES NO SENSE TO ME. Just revoked the lease for the MBP on DIR655 and no changes although this seemed to help MBP wake into connection 1 hour ago. OK a bit of walking about to report. Carried MBP across garden towards DIR655, a few other wifis show up on iStumbler, low signals all channel 1. Right next to DIR655 but iStumbler not showing it, although most other wifi's have gone. I'd say iStubler is suffering timeouts&hangs but hard to be sure. Lots of attempts to Airport on/off, join other etc and suddenly I get to connect, get given new IP (I revoked), can browse. Walk away, connection drops quite soon at 30 feet then reconnected briefly then died again. MUST ATTEND ELSEWHERE FOR A BIT...

    Read the article

  • Signal strength and Speed of wireless network

    - by Tim
    As shown by Lenovo Access Connections on my Windows 7, the wireless network I am using has a speed of 54.0Mbps but a signal strength of 88%. I am using WinSCP with unlimited speed to download files. WinSCP shows that the speed fluctuates between 100 and 120KiB/s. I was wondering what are the difference between the two speeds from Lenovo Access Connections and WinSCP? How can I tell the actual speed performance, for example, from the above measurements: speeds and the signal strength mentioned in the two places. Thanks and regards!

    Read the article

  • Signal strength and Speed of wireless network

    - by Tim
    As shown by Lenovo Access Connections on my Windows 7, the wireless network I am using has a speed of 54.0Mbps but a signal strength of 88%. I am using WinSCP with unlimited speed to download files. WinSCP shows that the speed fluctuates between 100 and 120KiB/s. I was wondering what are the difference between the two speeds from Lenovo Access Connections and WinSCP? How can I tell the actual speed performance, for example, from the above measurements: speeds and the signal strength mentioned in the two places. Thanks and regards!

    Read the article

  • Wi-fi signal with keeping the internet cable

    - by daGrevis
    So the situation is that I have Ethernet cable which provides internet to my computer. Thing I want is to have wi-fi connection in my house and Ethernet cable (like I have before) to use for my PC. I will use wi-fi for my laptop and mobile phone. I think I need router for that and I'm looking at Asus RT-N16 (suggested in Coding Horror) for it, but I am not sure. Is it the right thing for me and I will be able to get wi-fi signal and keep the Ethernet cable? I guess the system will be that current cable goes into router, router provides wi-fi signal and gives back new cable... or something like that. Thanks in any advice! And sorry if topic isn't in right site.

    Read the article

  • Upgraded to a GTX 580 - no video signal on boot

    - by MGOwen
    I have: New Corsair 550w PSU (should be more than enough) AsRock H61M u3s3 mobo (with latest updated BIOS) Just replaced my faithful HD 7790 GPU with a refurbished EVGA GTX 580 1.5GB. When I boot, it sounds like the PC boots to windows, and the 580's fan is spinning, but I can't get any video signal from the card. Old card and integrated graphics still work fine (when I replace and use those instead). I am using the DVI ports on the card with a DVI-VGA adapter until I can get my hands on a mini HDMI adapter tomorrow. Anyone ever heard of a GPU needed something special to make the VGA signal work? Hold down a key on startup or something? I can't even find a manual for this card.

    Read the article

  • Wifi Signal Strengths

    - by Phorce
    I hope that I have asked this question in the right topic. Basically I use BT (In the U.K.) and I have problems with my router receiving a strong signal in certain rooms of the house, which, therefore makes the internet really slow in some cases it won't work at all. I have had experience working with Virgin Media (UK) before and just changed the channel number and this worked fine, but, do not know if I would receive the same outcome on BT. Could anyone suggest any other things that I could try alongside of the channel change in order to /hopefully/ get a stronger signal, without having to install Ethernet cable?

    Read the article

  • Is error suppression acceptable in role of logic mechanism?

    - by Rarst
    This came up in code review at work in context of PHP and @ operator. However I want to try keep this in more generic form, since few question about it I found on SO got bogged down in technical specifics. Accessing array field, which is not set, results in error message and is commonly handled by following logic (pseudo code): if field value is set output field value Code in question was doing it like: start ignoring errors output field value stop ignoring errors The reasoning for latter was that it's more compact and readable code in this specific case. I feel that those benefits do not justify misuse (IMO) of language mechanics. Is such code is being "clever" in a bad way? Is discarding possible error (for any reason) acceptable practice over explicitly handling it (even if that leads to more extensive and/or intensive code)? Is it acceptable for programming operators to cross boundaries of intended use (like in this case using error handling for controlling output)? Edit I wanted to keep it more generic, but specific code being discussed was like this: if ( isset($array['field']) ) { echo '<li>' . $array['field'] . '</li>'; } vs the following example: echo '<li>' . @$array['field'] . '</li>';

    Read the article

  • Extrapolation using fft in octave

    - by CFP
    Using GNU octave, I'm computing a fft over a piece of signal, then eliminating some frequencies, and finally reconstructing the signal. This give me a nice approximation of the signal ; but it doesn't give me a way to extrapolate the data. Suppose basically that I have plotted three periods and a half of f: x -> sin(x) + 0.5*sin(3*x) + 1.2*sin(5*x) and then added a piece of low amplitude, zero-centered random noise. With fft/ifft, I can easily remove most of the noise ; but then how do I extrapolate 3 more periods of my signal data? (other of course that duplicating the signal). The math way is easy : you have a decomposition of your function as an infinite sum of sines/cosines, and you just need to extract a partial sum and apply it anywhere. But I don't quite get the programmatic way... Thanks!

    Read the article

  • Is it possible to control Visual Studio exception handling from the debugged code itself?

    - by mark
    Dear ladies and sirs. I am wondering if it is possible to control the Visual Studio exception handling options from the code itself. For instance, I would like to turn off stopping on FCE for a certain piece of code, that generates many FCE, however, I would like it to be active for all the other code. Is it possible to do it from code? Something like this: visualStudio.DoNotStopOnFCE() try { // some code generating many FCE } catch {} visualStudio.StopOnFCE() Thanks.

    Read the article

  • Exception Handling Differences Between 32/64 Bit

    - by Alois Kraus
    I do quite a bit of debugging .NET applications but from time to time I see things that are impossible (at a first look). I may ask you dear reader what your mental exception handling model is. Exception handling is easy after all right? Lets suppose the following code:         private void F1(object sender, EventArgs e)         {             try             {                 F2();             }             catch (Exception ex)             {                 throw new Exception("even worse Exception");             }           }           private void F2()         {             try             {                 F3();             }             finally             {                 throw new Exception("other exception");             }         }           private void F3()         {             throw new NotImplementedException();         }   What will the call stack look like when you break into the catch(Exception) clause in Windbg (32 and 64 bit on .NET 3.5 SP1)? The mental model I have is that when an exception is thrown the stack frames are unwound until the catch handler can execute. An exception does propagate the call chain upwards.   So when F3 does throw an exception the control flow will resume at the finally handler in F2 which does throw another exception hiding the original one (that is nasty) and then the new Exception will be catched in F1 where the catch handler is executed. So we should see in the catch handler in F1 as call stack only the F1 stack frame right? Well lets try it out in Windbg. For this I created a simple Windows Forms application with one button which does execute the F1 method in its click handler. When you compile the application for 64 bit and the catch handler is reached you will find with the following commands in Windbg   Load sos extension from the same path where mscorwks was loaded in the current process .loadby sos mscorwks   Beak on clr exceptions sxe clr   Continue execution g   Dump mixed call stack container C++  and .NET Stacks interleaved 0:000> !DumpStack OS Thread Id: 0x1d8 (0) Child-SP         RetAddr          Call Site 00000000002c88c0 000007fefa68f0bd KERNELBASE!RaiseException+0x39 00000000002c8990 000007fefac42ed0 mscorwks!RaiseTheExceptionInternalOnly+0x295 00000000002c8a60 000007ff005dd7f4 mscorwks!JIT_Throw+0x130 00000000002c8c10 000007fefa6942e1 WindowsFormsApplication1!WindowsFormsApplication1.Form1.F1(System.Object, System.EventArgs)+0xb4 00000000002c8c60 000007fefa661012 mscorwks!ExceptionTracker::CallHandler+0x145 00000000002c8d60 000007fefa711a72 mscorwks!ExceptionTracker::CallCatchHandler+0x9e 00000000002c8df0 0000000077b055cd mscorwks!ProcessCLRException+0x25e 00000000002c8e90 0000000077ae55f8 ntdll!RtlpExecuteHandlerForUnwind+0xd 00000000002c8ec0 000007fefa637c1a ntdll!RtlUnwindEx+0x539 00000000002c9560 000007fefa711a21 mscorwks!ClrUnwindEx+0x36 00000000002c9a70 0000000077b0554d mscorwks!ProcessCLRException+0x20d 00000000002c9b10 0000000077ae5d1c ntdll!RtlpExecuteHandlerForException+0xd 00000000002c9b40 0000000077b1fe48 ntdll!RtlDispatchException+0x3cb 00000000002ca220 000007fefdaeaa7d ntdll!KiUserExceptionDispatcher+0x2e 00000000002ca7e0 000007fefa68f0bd KERNELBASE!RaiseException+0x39 00000000002ca8b0 000007fefac42ed0 mscorwks!RaiseTheExceptionInternalOnly+0x295 00000000002ca980 000007ff005dd8df mscorwks!JIT_Throw+0x130 00000000002cab30 000007fefa6942e1 WindowsFormsApplication1!WindowsFormsApplication1.Form1.F2()+0x9f 00000000002cab80 000007fefa71b5b3 mscorwks!ExceptionTracker::CallHandler+0x145 00000000002cac80 000007fefa70dcd0 mscorwks!ExceptionTracker::ProcessManagedCallFrame+0x683 00000000002caed0 000007fefa7119af mscorwks!ExceptionTracker::ProcessOSExceptionNotification+0x430 00000000002cbd90 0000000077b055cd mscorwks!ProcessCLRException+0x19b 00000000002cbe30 0000000077ae55f8 ntdll!RtlpExecuteHandlerForUnwind+0xd 00000000002cbe60 000007fefa637c1a ntdll!RtlUnwindEx+0x539 00000000002cc500 000007fefa711a21 mscorwks!ClrUnwindEx+0x36 00000000002cca10 0000000077b0554d mscorwks!ProcessCLRException+0x20d 00000000002ccab0 0000000077ae5d1c ntdll!RtlpExecuteHandlerForException+0xd 00000000002ccae0 0000000077b1fe48 ntdll!RtlDispatchException+0x3cb 00000000002cd1c0 000007fefdaeaa7d ntdll!KiUserExceptionDispatcher+0x2e 00000000002cd780 000007fefa68f0bd KERNELBASE!RaiseException+0x39 00000000002cd850 000007fefac42ed0 mscorwks!RaiseTheExceptionInternalOnly+0x295 00000000002cd920 000007ff005dd968 mscorwks!JIT_Throw+0x130 00000000002cdad0 000007ff005dd875 WindowsFormsApplication1!WindowsFormsApplication1.Form1.F3()+0x48 00000000002cdb10 000007ff005dd786 WindowsFormsApplication1!WindowsFormsApplication1.Form1.F2()+0x35 00000000002cdb60 000007ff005dbe6a WindowsFormsApplication1!WindowsFormsApplication1.Form1.F1(System.Object, System.EventArgs)+0x46 00000000002cdbc0 000007ff005dd452 System_Windows_Forms!System.Windows.Forms.Control.OnClick(System.EventArgs)+0x5a   Hm okaaay. I see my method F1 two times in this call stack. Looks like we did get some recursion bug. But that can´t be given the obvious code above. Let´s try the same thing in a 32 bit process.  0:000> !DumpStack OS Thread Id: 0x33e4 (0) Current frame: KERNELBASE!RaiseException+0x58 ChildEBP RetAddr  Caller,Callee 0028ed38 767db727 KERNELBASE!RaiseException+0x58, calling ntdll!RtlRaiseException 0028ed4c 68b9008c mscorwks!Binder::RawGetClass+0x20, calling mscorwks!Module::LookupTypeDef 0028ed5c 68b904ff mscorwks!Binder::IsClass+0x23, calling mscorwks!Binder::RawGetClass 0028ed68 68bfb96f mscorwks!Binder::IsException+0x14, calling mscorwks!Binder::IsClass 0028ed78 68bfb996 mscorwks!IsExceptionOfType+0x23, calling mscorwks!Binder::IsException 0028ed80 68bfbb1c mscorwks!RaiseTheExceptionInternalOnly+0x2a8, calling KERNEL32!RaiseExceptionStub 0028eda8 68ba0713 mscorwks!Module::ResolveStringRef+0xe0, calling mscorwks!BaseDomain::GetStringObjRefPtrFromUnicodeString 0028edc8 68b91e8d mscorwks!SetObjectReferenceUnchecked+0x19 0028ede0 68c8e910 mscorwks!JIT_Throw+0xfc, calling mscorwks!RaiseTheExceptionInternalOnly 0028ee44 68c8e734 mscorwks!JIT_StrCns+0x22, calling mscorwks!LazyMachStateCaptureState 0028ee54 68c8e865 mscorwks!JIT_Throw+0x1e, calling mscorwks!LazyMachStateCaptureState 0028eea4 02ffaecd (MethodDesc 0x7af08c +0x7d WindowsFormsApplication1.Form1.F1(System.Object, System.EventArgs)), calling mscorwks!JIT_Throw 0028eeec 02ffaf19 (MethodDesc 0x7af098 +0x29 WindowsFormsApplication1.Form1.F2()), calling 06370634 0028ef58 02ffae37 (MethodDesc 0x7a7bb0 +0x4f System.Windows.Forms.Control.OnClick(System.EventArgs))   That does look more familar. The call stack has been unwound and we do see only some frames into the history where the debugger was smart enough to find out that we have called F2 from F1. The exception handling on 64 bit systems does work quite differently which seems to have the nice property to remember the called methods not only during the first pass of exception filter clauses (during first pass all catch handler are called if they are going to catch the exception which is about to be thrown)  but also when the actual stack unwind has taken place. This makes it possible to follow not only the call stack right at the moment but also to look into the “history” of the catch/finally clauses. In a 64 bit process you only need to look at the ExceptionTracker to find out if a catch or finally handler was called. The two frames ProcessManagedCallFrame/CallHandler does indicate a finally clause whereas CallCatchHandler/CallHandler indicates a catch clause. That was a interesting one. Oh and by the way if you manage to load the Microsoft symbols you can also find out the hidden exception which. When you encounter in the call stack a line 0016eb34 75b79617 KERNELBASE!RaiseException+0x58 ====> Exception Code e0434f4d cxr@16e850 exr@16e838 Then it is a good idea to execute .exr 16e838 !analyze –v to find out more. In the managed world it is even easier since we can dump the objects allocated on the stack which have not yet been garbage collected to look at former method parameters. The command !dso which is the abbreviation for dump stack objects will give you 0:000> !dso OS Thread Id: 0x46c (0) ESP/REG  Object   Name 0016dd4c 020737f0 System.Exception 0016dd98 020737f0 System.Exception 0016dda8 01f5c6cc System.Windows.Forms.Button 0016ddac 01f5d2b8 System.EventHandler 0016ddb0 02071744 System.Windows.Forms.MouseEventArgs 0016ddc0 01f5d2b8 System.EventHandler 0016ddcc 01f5c6cc System.Windows.Forms.Button 0016dddc 020737f0 System.Exception 0016dde4 01f5d2b8 System.EventHandler 0016ddec 02071744 System.Windows.Forms.MouseEventArgs 0016de40 020737f0 System.Exception 0016de80 02071744 System.Windows.Forms.MouseEventArgs 0016de8c 01f5d2b8 System.EventHandler 0016de90 01f5c6cc System.Windows.Forms.Button 0016df10 02073784 System.SByte[] 0016df5c 02073684 System.NotImplementedException 0016e2a0 02073684 System.NotImplementedException 0016e2e8 01ed69f4 System.Resources.ResourceManager From there it is easy to do 0:000> !pe 02073684 Exception object: 02073684 Exception type: System.NotImplementedException Message: Die Methode oder der Vorgang sind nicht implementiert. InnerException: <none> StackTrace (generated):     SP       IP       Function     0016ECB0 006904AD WindowsFormsApplication2!WindowsFormsApplication2.Form1.F3()+0x35     0016ECC0 00690411 WindowsFormsApplication2!WindowsFormsApplication2.Form1.F2()+0x29     0016ECF0 0069038F WindowsFormsApplication2!WindowsFormsApplication2.Form1.F1(System.Object, System.EventArgs)+0x3f StackTraceString: <none> HResult: 80004001 to see the former exception. That´s all for today.

    Read the article

  • Download the ZFSSA Objection Handling document (PDF)

    - by swalker
    View and download the new ZFS Storage Appliance objection handling document from the Oracle HW Technical Resource Centre here. This document aims to address the most common objections encountered when positioning the ZFS Storage Appliance disk systems in production environments. It will help you to be more successful in establishing the undeniable benefits of the Oracle ZFS Storage Appliance in your customers´ IT environments. If you do not already have an account to access the Oracle Hardware Technical Resource Centre, please click here and follow the instructions to register.

    Read the article

  • Handling permissions in a MVP application

    - by Chathuranga
    In a windows forms payroll application employing MVP pattern (for a small scale client) I'm planing user permission handling as follows (permission based) as basically its implementation should be less complicated and straight forward. NOTE : System could be simultaneously used by few users (maximum 3) and the database is at the server side. This is my UserModel. Each user has a list of permissions given for them. class User { string UserID { get; set; } string Name { get; set; } string NIC {get;set;} string Designation { get; set; } string PassWord { get; set; } List <string> PermissionList = new List<string>(); bool status { get; set; } DateTime EnteredDate { get; set; } } When user login to the system it will keep the current user in memory. For example in BankAccountDetailEntering view I control the controller permission as follows. public partial class BankAccountDetailEntering : Form { bool AccountEditable {get; set;} private void BankAccountDetailEntering_Load(object sender, EventArgs e) { cmdEditAccount.enabled = false; OnLoadForm (sender, e); // Event fires... If (AccountEditable ) { cmdEditAccount.enabled=true; } } } In this purpose my all relevant presenters (like BankAccountDetailPresenter) should aware of UserModel as well in addition to the corresponding business Model it is presenting to the View. class BankAccountDetailPresenter { BankAccountDetailEntering _View; BankAccount _Model; User _UserModel; DataService _DataService; BankAccountDetailPresenter( BankAccountDetailEntering view, BankAccount model, User userModel, DataService dataService ) { _View=view; _Model = model; _UserModel = userModel; _DataService = dataService; WireUpEvents(); } private void WireUpEvents() { _View.OnLoadForm += new EventHandler(_View_OnLoadForm); } private void _View_OnLoadForm(Object sender, EventArgs e) { foreach(string s in _UserModel.PermissionList) { If( s =="CanEditAccount") { _View.AccountEditable =true; return; } } } public Show() { _View.ShowDialog(); } } So I'm handling the user permissions in the presenter iterating through the list. Should this be performed in the Presenter or View? Any other more promising ways to do this? Thanks.

    Read the article

  • Exception handling in 3-Tier Architecture

    Exception handling in 3-Tier Architecture using Enterprise Library...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Handling SQL Server Errors

    This article covers the basics of TRY CATCH error handling in T-SQL introduced in SQL Server 2005. It includes the usage of common functions to return information about the error and using the TRY CATCH block in stored procedures and transactions.

    Read the article

  • Slowly Changing Dimensions handling in PowerPivot (and BISM?)

    - by Marco Russo (SQLBI)
    During the PowerPivot Workshop in London we received many interesting questions and Alberto had the inspiration to write this nice post about Slowly Changing Dimensions handling in PowerPivot. It is interesting the consideration about SCD Type I attributes in a SCD Type II dimension – you can probably generate them in a more dynamic way in PowerPivot (thanks to Vertipaq and DAX) instead of relying on a relational table containing all the data you need, which usually requires a more complex ETL process....(read more)

    Read the article

  • Gracefully Handling Deadlocks

    - by Derek Dieter
    In some situations, deadlocks may need to be dealt with not by changing the source of the deadlock, but by changing handling the deadlock gracefully. An example of this may be an external subscription that runs on a schedule deadlocking with another process. If the subscription deadlocks then it would be ok to [...]

    Read the article

  • On Handling Dates in SQL

    The calendar is inherently complex by the very nature of the astronomy that underlies the year, and the conflicting historical conventions. The handling of dates in TSQL is even more complex because, when SQL Server was Sybase, it was forced by the lack of prevailing standards in SQL to create its own ways of processing and formatting dates and times. Joe Celko looks forward to a future when it is possible to write standard SQL date-processing code with SQL Server.

    Read the article

  • Item Framework for Handling INamingContainer

    Item Framework for Handling INamingContainer...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Handling SQL Server Errors

    This article covers the basics of TRY CATCH error handling in T-SQL introduced in SQL Server 2005. It includes the usage of common functions to return information about the error and using the TRY CATCH block in stored procedures and transactions.

    Read the article

  • COMPAQ Tower No Signal to monitor

    - by Lancelot
    Hi there, I have had some troubles with this: I received a compaq tower: Compaq Presario SR1224NX Onboard VGA Windows XP SP2 from a friend. It was given to me on condition i give her the files back. My plan was to turn this into an Ubuntu Server. It booted up no problems even with the ubuntu live disc. After a normal shutdown(not unpluggin the power cord and not doing a hard shutdown with the power button), it would not restart even after SEVERAL attempts. I realized the light next to the power supply would flash very rapidly. I researched and found out it was one of two things: a dead power supply or the cables to the motherboard and to the disks etc. Thus i checked to ensure the cables were fine(and they were). I purchased a Power Supply (this one has 400 watts, the initial had 250) and installed it. The tower now boots. It booted into the live disk and everything. After a normal shutdown, it now restarts but is not sending signal to my monitor. I have tried several monitors in which i assure work perfectly but not with this tower(i recall it did show display after replacing the power supply). The monitors are ACER. This is different than most "no Signal" problems since i am not using an external Video Card, this is onboard VGA. Thanks!

    Read the article

  • COMPAQ Tower No Signal to monitor

    - by Lancelot
    I received a Compaq tower: Compaq Presario SR1224NX Onboard VGA Windows XP SP2 from a friend. My plan was to turn this into an Ubuntu Server. It booted up with no problems even with the Ubuntu live disc. After a normal shutdown (not unplugging the power cord and not doing a hard shutdown with the power button), it would not restart even after SEVERAL attempts. I realized the light next to the power supply would flash very rapidly. I researched and found out it was one of two things: a dead power supply or the cables to the motherboard and to the disks might be faulty, etc. Thus, I checked to ensure the cables were fine(and they were). I purchased a Power Supply (this one has 400 watts, the initial had 250) and installed it. The tower was able to boot into the live disk and everything. After a normal shutdown, it now restarts but is not sending signal to my monitor. I have tried several monitors in which I know work perfectly but not with this tower (I recall that it did show display after replacing the power supply). The monitors are ACER. This is different than most "no Signal" problems since I am not using an external Video Card, this is onboard VGA.

    Read the article

  • How can I set up .NET UnhandledException handling in a Windows service?

    - by Mike Pateras
    protected override void OnStart(string[] args) { AppDomain.CurrentDomain.UnhandledException += new UnhandledExceptionEventHandler(CurrentDomain_UnhandledException); Thread.Sleep(10000); throw new Exception(); } void CurrentDomain_UnhandledException(object sender, UnhandledExceptionEventArgs e) { } I attached a debugger to the above code in my windows service, setting a breakpoint in CurrentDomain_UnhandledException, but it was never hit. The exception pops up saying that it is unhandled, and then the service stops. I even tried putting some code in the event handler, in case it was getting optimized away. Is this not the proper way to set up unhandled exception handling in a windows service?

    Read the article

  • How can I set up .Net unhanlded exception handling in a windows service?

    - by Mike Pateras
    protected override void OnStart(string[] args) { AppDomain.CurrentDomain.UnhandledException += new UnhandledExceptionEventHandler(CurrentDomain_UnhandledException); Thread.Sleep(10000); throw new Exception(); } void CurrentDomain_UnhandledException(object sender, UnhandledExceptionEventArgs e) { } I attached a debugger to the above code in my windows service, setting a breakpoint in CurrentDomain_UnhandledException, but it was never hit. The exception pops up saying that it is unhandled, and then the service stops. I even tried putting some code in the event handler, in case it was getting optimized away. Is this not the proper way to set up unhandled exception handling in a windows service?

    Read the article

< Previous Page | 8 9 10 11 12 13 14 15 16 17 18 19  | Next Page >