Search Results

Search found 12283 results on 492 pages for 'tcp port'.

Page 120/492 | < Previous Page | 116 117 118 119 120 121 122 123 124 125 126 127  | Next Page >

  • C: incompatible types in assignment

    - by The.Anti.9
    I'm writing a program to check to see if a port is open in C. One line in particular copies one of the arguments to a char array. However, when I try to compile, it says: error: incompatible types in assignment Heres the code. The error is on the assignment of addr #include <sys/socket.h> #include <sys/time.h> #include <sys/types.h> #include <arpa/inet.h> #include <netinet/in.h> #include <errno.h> #include <fcntl.h> #include <stdio.h> #include <netdb.h> #include <stdlib.h> #include <string.h> #include <unistd.h> int main(int argc, char **argv) { u_short port; /* user specified port number */ char addr[1023]; /* will be a copy of the address entered by u */ struct sockaddr_in address; /* the libc network address data structure */ short int sock = -1; /* file descriptor for the network socket */ port = atoi(argv[1]); addr = strncpy(addr, argv[2], 1023); bzero((char *)&address, sizeof(address)); /* init addr struct */ address.sin_addr.s_addr = inet_addr(addr); /* assign the address */ address.sin_port = htons(port); /* translate int2port num */ sock = socket(AF_INET, SOCK_STREAM, 0); if (connect(sock,(struct sockaddr *)&address,sizeof(address)) == 0) { printf("%i is open\n", port); } if (errno == 113) { fprintf(stderr, "Port not open!\n"); } close(sock); return 0; } I'm new to C, so I'm not sure why it would do this.

    Read the article

  • Unit testing a method with many possible outcomes

    - by Cthulhu
    I've built a simple~ish method that constructs an URL out of approximately 5 parts: base address, port, path, 'action', and a set of parameters. Out of these, only the address part is mandatory, the other parts are all optional. A valid URL has to come out of the method for each permutation of input parameters, such as: address address port address port path address path address action address path action address port action address port path action address action params address path action params address port action params address port path action params andsoforth. The basic approach for this is to write one unit test for each of these possible outcomes, each unit test passing the address and any of the optional parameters to the method, and testing the outcome against the expected output. However, I wonder, is there a Better (tm) way to handle a case like this? Are there any (good) unit test patterns for this? (rant) I only now realize that I've learned to write unit tests a few years ago, but never really (feel like) I've advanced in the area, and that every unit test is a repeat of building parameters, expected outcome, filling mock objects, calling a method and testing the outcome against the expected outcome. I'm pretty sure this is the way to go in unit testing, but it gets kinda tedious, yanno. Advice on that matter is always welcome. (/rant) (note) christmas weekend approaching, probably won't reply to suggestions until next week. (/note)

    Read the article

  • PHP Infine Loope Problem

    - by Ashwin
    function httpGet( $url, $followRedirects=true ) { global $final_url; $url_parsed = parse_url($url); if ( empty($url_parsed['scheme']) ) { $url_parsed = parse_url('http://'.$url); } $final_url = $url_parsed; $port = $url_parsed["port"]; if ( !$port ) { $port = 80; } $rtn['url']['port'] = $port; $path = $url_parsed["path"]; if ( empty($path) ) { $path="/"; } if ( !empty($url_parsed["query"]) ) { $path .= "?".$url_parsed["query"]; } $rtn['url']['path'] = $path; $host = $url_parsed["host"]; $foundBody = false; $out = "GET $path HTTP/1.0\r\n"; $out .= "Host: $host\r\n"; $out .= "User-Agent: Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.8.1) Gecko/20061010 Firefox/2.0\r\n"; $out .= "Connection: Close\r\n\r\n"; if ( !$fp = @fsockopen($host, $port, $errno, $errstr, 30) ) { $rtn['errornumber'] = $errno; $rtn['errorstring'] = $errstr; } fwrite($fp, $out); while (!@feof($fp)) { $s = @fgets($fp, 128); if ( $s == "\r\n" ) { $foundBody = true; continue; } if ( $foundBody ) { $body .= $s; } else { if ( ($followRedirects) && (stristr($s, "location:") != false) ) { $redirect = preg_replace("/location:/i", "", $s); return httpGet( trim($redirect) ); } $header .= $s; } } fclose($fp); return(trim($body)); } This code sometimes go infinite loop. What's wrong here?

    Read the article

  • Python client / server question

    - by AustinM
    I'm working on a bit of a project in python. I have a client and a server. The server listens for connections and once a connection is received it waits for input from the client. The idea is that the client can connect to the server and execute system commands such as ls and cat. This is my server code: import sys, os, socket host = '' port = 50105 s = socket.socket(socket.AF_INET, socket.SOCK_STREAM) s.bind((host, port)) print("Server started on port: ", port) s.listen(5) print("Server listening\n") conn, addr = s.accept() print 'New connection from ', addr while (1): rc = conn.recv(5) pipe = os.popen(rc) rl = pipe.readlines() file = conn.makefile('w', 0) file.writelines(rl[:-1]) file.close() conn.close() And this is my client code: import sys, socket s = socket.socket(socket.AF_INET, socket.SOCK_STREAM) host = 'localhost' port = input('Port: ') s.connect((host, port)) cmd = raw_input('$ ') s.send(cmd) file = s.makefile('r', 0) sys.stdout.writelines(file.readlines()) When I start the server I get the right output, saying the server is listening. But when I connect with my client and type a command the server exits with this error: Traceback (most recent call last): File "server.py", line 21, in <module> rc = conn.recv(2) File "/usr/lib/python2.6/socket.py", line 165, in _dummy raise error(EBADF, 'Bad file descriptor') socket.error: [Errno 9] Bad file descriptor On the client side, I get the output of ls but the server gets screwed up.

    Read the article

  • Python server open all ports

    - by user1670178
    I am trying to open all ports using this code, why can I not create a loop to perform this function? http://www.kellbot.com/2010/02/tutorial-writing-a-tcp-server-in-python/ #!/usr/bin/python # This is server.py file ##server.py from socket import * #import the socket library n=1025 while n<1050: ##let's set up some constants HOST = '' #we are the host PORT = n #arbitrary port not currently in use ADDR = (HOST,PORT) #we need a tuple for the address BUFSIZE = 4096 #reasonably sized buffer for data ## now we create a new socket object (serv) ## see the python docs for more information on the socket types/flags serv = socket( AF_INET,SOCK_STREAM) ##bind our socket to the address serv.bind((ADDR)) #the double parens are to create a tuple with one element serv.listen(5) #5 is the maximum number of queued connections we'll allow serv = socket( AF_INET,SOCK_STREAM) ##bind our socket to the address serv.bind((ADDR)) #the double parens are to create a tuple with one element serv.listen(5) #5 is the maximum number of queued connections we'll allow print 'listening...' n=n+1 conn,addr = serv.accept() #accept the connection print '...connected!' conn.send('TEST') conn.close() How do I make this work so that I can specify input range and have the server open all ports up to 65535? #!/usr/bin/python # This is server.py file from socket import * #import the socket library startingPort=input("\nPlease enter starting port: ") startingPort=int(startingPort) #print startingPort def connection(): ## let's set up some constants HOST = '' #we are the host PORT = startingPort #arbitrary port not currently in use ADDR = (HOST,PORT) #we need a tuple for the address BUFSIZE = 4096 #reasonably sized buffer for data def socketObject(): ## now we create a new socket object (serv) serv = socket( AF_INET,SOCK_STREAM) def bind(): ## bind our socket to the address serv = socket( AF_INET,SOCK_STREAM) serv.bind((ADDR)) #the double parens are to create a tuple with one element serv.listen(5) #5 is the maximum number of queued connections we'll allow serv = socket( AF_INET,SOCK_STREAM) print 'listening...' def accept(): conn,addr = serv.accept() #accept the connection print '...connected!' conn.send('TEST') def close(): conn.close() ## Main while startingPort<65535: connection() socketObject() bind() accept() startingPort=startingPort+1

    Read the article

  • PHP Infine Loop Problem

    - by Ashwin
    function httpGet( $url, $followRedirects=true ) { global $final_url; $url_parsed = parse_url($url); if ( empty($url_parsed['scheme']) ) { $url_parsed = parse_url('http://'.$url); } $final_url = $url_parsed; $port = $url_parsed["port"]; if ( !$port ) { $port = 80; } $rtn['url']['port'] = $port; $path = $url_parsed["path"]; if ( empty($path) ) { $path="/"; } if ( !empty($url_parsed["query"]) ) { $path .= "?".$url_parsed["query"]; } $rtn['url']['path'] = $path; $host = $url_parsed["host"]; $foundBody = false; $out = "GET $path HTTP/1.0\r\n"; $out .= "Host: $host\r\n"; $out .= "User-Agent: Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.8.1) Gecko/20061010 Firefox/2.0\r\n"; $out .= "Connection: Close\r\n\r\n"; if ( !$fp = @fsockopen($host, $port, $errno, $errstr, 30) ) { $rtn['errornumber'] = $errno; $rtn['errorstring'] = $errstr; } fwrite($fp, $out); while (!@feof($fp)) { $s = @fgets($fp, 128); if ( $s == "\r\n" ) { $foundBody = true; continue; } if ( $foundBody ) { $body .= $s; } else { if ( ($followRedirects) && (stristr($s, "location:") != false) ) { $redirect = preg_replace("/location:/i", "", $s); return httpGet( trim($redirect) ); } $header .= $s; } } fclose($fp); return(trim($body)); } This code sometimes go infinite loop. What's wrong here?

    Read the article

  • SQL Server 2008: Can't connect to remote server via management studio but can telnet in fine

    - by WarpKid
    Hi, I am in the process of trying to configure SQL Server 2008 to accept remote connections. I have been through all the documentation I can find and yet when I attempt to connect through management studio I get an error stating that the server could not be found. Interestingly I can connect through telnet to the remote server via the port that sql server is listening on. In the SQL Server logs I can see the connection attempt. So SQL Server is up and running and listening on the correct port - no firewall blocking it. It would appear that by default SQL Server is listening on port 50314 by default but management studio attempts to connect on port 1433.Weird. Server Management Studio = no dice. Anyone got any ideas? Server is set to allow remote connections - TCP IP is enabled, firewall is off. Thanks UPDATE FOR TO CLEAR THINGS UP A BIT We are seeing the connection attempt when we telnet in on port 50314 in the sql server logs. When we login through management studio we see it attempting connection on port 1433. There is no sign of this connection attempt in the logs.

    Read the article

  • Freeradius authentication failed for unknown reason

    - by Moein7tl
    I followed this instruction to force freeradius to use mysql database. and run freeradius in debug mod. but it rejects all authentication. mysql database : mysql select * from radcheck; +----+----------+-----------+----+---------+ | id | username | attribute | op | value | +----+----------+-----------+----+---------+ | 1 | test | Password | == | test123 | | 2 | test | Auth-Type | == | Local | +----+----------+-----------+----+---------+ 2 rows in set (0.02 sec) radtest command : # radtest test test123 localhost 0 testing123 Sending Access-Request of id 235 to 127.0.0.1 port 1812 User-Name = "test" User-Password = "test123" NAS-IP-Address = 127.0.0.1 NAS-Port = 0 Message-Authenticator = 0x00000000000000000000000000000000 rad_recv: Access-Reject packet from host 127.0.0.1 port 1812, id=235, length=20 radiusd debug mod log: rad_recv: Access-Request packet from host 127.0.0.1 port 51034, id=235, length=74 User-Name = "test" User-Password = "test123" NAS-IP-Address = 127.0.0.1 NAS-Port = 0 Message-Authenticator = 0xbf111cbbae24fb0f0a558bfa26f53476 # Executing section authorize from file /usr/local/etc/raddb/sites-enabled/default +- entering group authorize {...} ++[preprocess] returns ok ++[chap] returns noop ++[mschap] returns noop ++[digest] returns noop [suffix] No '@' in User-Name = "test", looking up realm NULL [suffix] No such realm "NULL" ++[suffix] returns noop [eap] No EAP-Message, not doing EAP ++[eap] returns noop ++[files] returns noop ++[expiration] returns noop ++[logintime] returns noop [pap] WARNING! No "known good" password found for the user. Authentication may fail because of this. ++[pap] returns noop ERROR: No authenticate method (Auth-Type) found for the request: Rejecting the user Failed to authenticate the user. Using Post-Auth-Type Reject # Executing group from file /usr/local/etc/raddb/sites-enabled/default +- entering group REJECT {...} [attr_filter.access_reject] expand: %{User-Name} - test attr_filter: Matched entry DEFAULT at line 11 ++[attr_filter.access_reject] returns updated Delaying reject of request 20 for 1 seconds Going to the next request Waking up in 0.9 seconds. Sending delayed reject for request 20 Sending Access-Reject of id 235 to 127.0.0.1 port 51034 Waking up in 4.9 seconds. Cleaning up request 20 ID 235 with timestamp +4325 Ready to process requests. where is the problem and how should I solve it?

    Read the article

  • cygwin sshd times out for remote login

    - by reve_etrange
    I have configured SSHD using Cygwin on Windows 7. I have checked and double-checked all of the following points: Port forwarding is correctly configured Windows Firewall is configured to pass port 22 Local login attempts (using Cygwin SSH) succeed sshd_config has UseDNS No Using nmap from remote machine confirms port 22 is accessible /etc/passwd and /etc/group are correctly populated However, remote login attempts time out. This includes from the local network. user@host:~$ ssh -vvv [email protected] OpenSSH_5.5p1 Debian-4ubuntu6, OpenSSL 0.9.8o 01 Jun 2010 debug1: Reading configuration data /home/user/.ssh/config debug1: Applying options for * debug1: Reading configuration data /etc/ssh/ssh_config debug1: Applying options for * debug2: ssh_connect: needpriv 0 debug1: Connecting to the.ip.add.ress [the.ip.add.ress] port 22. debug1: connect to address the.ip.add.ress port 22: Connection timed out ssh: connect to the.ip.add.ress port 22: Connection timed out No messages are logged to /var/log/sshd.log. I suspect that there is a permissions issue with a particular file somewhere, however I have checked the permissions of all my Cygwin binaries, DLLs and the particular files important to Cygwin sshd, including all of: /etc/passwd /etc/group /var /var/log/sshd.log /var/empty Others who have reported this or similar errors appear to have missed one of the points enumerated above. Can anyone point me to a possible solution?

    Read the article

  • IIS running but not serving content

    - by Kyle
    I have an internal dev server running Windows 2k8 R2 with the Web and FTP Server roles set up which won't serve any content at all. Trying to connect from another host via telnet yields 'connection failed': c:\>telnet devserver 80 Connecting To devserver...Could not open connection to the host, on port 80: Conn ect failed Using netstat -an | find "80" on the dev server returns no connections on port 80 (a few on 1801, etc) tcpview confirms this, listing no open connections on port 80. The following services related to the Web role are running: World Wide Web Publishing Service Application Host Helper Service Microsoft FTP Service (ftp connections to port 21 are granted) Windows Process Activation Service The default website bindings are: Type Host Name Port IP Address Binding Information http 80 * net.tcp 808:* net.pipe * net.msmq localhost msmq.formatname localhost When setting up a new application under the default site, the test function passes both connection/authorisation only if the 'connect as' user is local admin, otherwise the test errors with 'invalid application path'. At no point is the W3SVC service PID bound to port 80 (it is running and bound to 21 for ftp). There are no W3SVC log directory at c:\inetpub\logs\LogFiles\ (only FTPSVC2), and no HTTPERR directory at c:\windows\system32\ or c:\windows\system32\logfiles\. There do not appear to be any related errors in the event logs. I'd really appreciate any thoughts on be a good place dig into what's (not) going on here!

    Read the article

  • Using two ports on my ZyXel USG gateway to patch two devices together?

    - by Matthew Beza
    I don't know if this is possible but it would save me many long drives! I have drawn, with my epic MS Paint skills, my current setup. I have a ZyXel USG300 Gateway with a built in 5 port switch. It supports bridging, tunnles, VLANs, etc.. I have a Cisco WLC2112 plugged into port 6 (P6). The cisco is set to 192.168.6.2 and P6 is set to 192.168.6.1. This works but I need to incorporate a Nomadix AG3000 to handle guests. (Router (A) in the picture). So I need the Cisco WLC2112 to use the Nomadix as if it where plugged into it's LAN port. Right now the Nomadix WAN Port is plugged into (P2) on the ZyXel, and the Nomadix LAN port is plugged into (P3). Is it possible to set something up where (P3) and (P6) are somehow "Patched" as if the Cisco was plugged directly into the Nomadix LAN port? Basically making the ZyXel a fancy Cat5e coupler?

    Read the article

  • Configuring vlans on Cisco SG200 series switch with Ubuntu server

    - by nixnotwin
    I created a vlan on Ubuntu with vconfig tool with 21 as id and eth1 as the host port. I connected eth1 to one of the ports on the swtich (GE23) as all ports trunk by default. In the webgui I created a vlan named test with the id 21 and I made GE2 are port as an access port. In port to vlan mapping I selected vlan 21 and added it port GE2 by selecting untagged option. I have assigned 192.168.1.1/24 as the ip of eth1.21 on Ubuntu. If I connect another cleint pc to GE2 port with a ip of 192.168.1.2/24 I cannot ping the server ip (192.168.1.1/24). Ping from server to client also does not work. I inspected packets that are sent out eth1 on the server and I could see the vlan 21 tag. And I connect the other end of the cable to a different Linux pc and inspected the packets but no vlan tags can be seen. What could be preventing me from getting vlans working? Edit 1 screenshots:

    Read the article

  • Router and Switch VLAN Configuration for Isolated Network

    - by Ben
    I haven't worked with VLANs much in the past and I was hoping if I could get a good explanation of what I need to setup for this to work. I have a Netgear WNR2000v2 router and a Netgear GS108T smart switch currently in my network. The fourth port on the router connects to port one on the switch. I would like to be able to isolated port 8 on the switch for use as a "guest port" when I bring home malware infested PCs for repair. I figured the VLAN capabilities of the GS108T would be able to do this for me, but I think I have a misunderstanding of how the VLAN actually works. Port 8 needs internet access but should not be able to communicate with the rest of the PCs on the home network. The subnet for the home network is 192.168.1.0/24 and I would like the guest PC to have A) 192.168.1.64 or B) 192.168.2.2. I am reading a lot of stuff about port trunking and VLAN membership, but I am confused as to which setup needs to be in place to make this work. Any help is greatly appreciated! Let me know if there is more information I need to provide. Definitely looking to learn something from this project. Thanks!

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • Trying to use a SmartHost with my Exchange 2010 server

    - by Pure.Krome
    Hi folks, I'm trying to use a SmartHost with my Exchange 2010 Server. SmartHost details: Secure SMTPS: securemail.internode.on.net 465 <-- Note: that's port 465 Configure your existing SMTP settings (in your email program) to: use authentication (enter your Internode username and password, enter your username as [email protected]). enable SSL for sending email (SMTPS). So I've added the smart host details to my Org Config -> Hub Transport. I then used PowerShell to add the port:- Set-SendConnector "securemail.internode.on.net" -port 465 I've then added my username/password (as suggested above) to the SmartHost as Basic Authentication (with no TLS). Then I try sending an email and I get the following error message :- 451 4.4.0 Primary target IP address responded with: "421 4.4.2 Connection dropped due to ConnectionReset." So i'm not sure how to continue. I also tried ticking the TLS box but stll I get the same error. If i don't use SMTPS (secure SMTP, on port 465) and use basic SMTP on port 25 with no Authentication, email gets sent. Any ideas? EDIT: Btw, I can telnet to that server on port 465 from my mail server .. just to make sure i'm not getting firewall'd, etc.

    Read the article

  • How to get gigabit network speeds on Windows XP?

    - by JB
    We've just installed gigabit switches at work, and things on the Linux side are going well. Our linux boxes, which use a Intel Corporation 82566DM-2 Gigabit nic (according to lspci), consistently get over 900 mbits/sec: iperf -c ipserver ------------------------------------------------------------ Client connecting to ipserver, TCP port 5001 TCP window size: 16.0 KByte (default) ------------------------------------------------------------ [ 3] local 192.168.40.9 port 39823 connected with 192.168.1.115 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 1.08 GBytes 929 Mbits/sec We have a bunch of Windows XP 64-bit machines that use Broadcom NetXtreme 57xx cards. I spent around a day trying to get equivalent speeds on them, but couldn't get above 200 Mbits/sec. I noticed the Windows iperf tests said that the TCP window size was 8 Kb by default (as opposed to 16 Kb on Linux, so I modified my test to reflect that. Still no love. I went to Broadcom's site, downloaded the latest drivers for the card and installed. Still no love. However, finally, I tried a 64 Kb window size with the new drivers, and finally an improvement! $ iperf -c ipserver -w64k ------------------------------------------------------------ Client connecting to ipserver, TCP port 5001 TCP window size: 64.0 KByte ------------------------------------------------------------ [ 3] local 192.168.40.214 port 1848 connected with 192.168.1.115 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 933 MBytes 782 Mbits/sec Much better, but still not really taking advantage of the full capabilities of the network. If the Linux box can reach 950 Mbits/sec consistently, this box should be able to as well. Also, if you're wondering about the medium, this is over the same cable...I'm switching back and forth. Any suggestion or ideas would be really welcome. Thanks!

    Read the article

  • OpenBSD logins via SSH seem to be ignoring my configured radius server

    - by Steve Kemp
    I've installed and configured a radius server upon my localhost - it is delegating auth to a remote LDAP server. Initially things look good: I can test via the console: # export user=skemp # export pass=xxx # radtest $user $pass localhost 1812 $secret Sending Access-Request of id 185 to 127.0.0.1 port 1812 User-Name = "skemp" User-Password = "xxx" NAS-IP-Address = 192.168.1.168 NAS-Port = 1812 rad_recv: Access-Accept packet from host 127.0.0.1 port 1812, id=185, Similarly I can use the login tool to do the same thing: bash-4.0# /usr/libexec/auth/login_radius -d -s login $user radius Password: $pass authorize However remote logins via SSH are failing, and so are invokations of "login" started by root. Looking at /var/log/radiusd.log I see no actual log of success/failure which I do see when using either of the previous tools. Instead sshd is just logging: sshd[23938]: Failed publickey for skemp from 192.168.1.9 sshd[23938]: Failed keyboard-interactive for skemp from 192.168.1.9 port 36259 ssh2 sshd[23938]: Failed password for skemp from 192.168.1.9 port 36259 ssh2 In /etc/login.conf I have this: # Default allowed authentication styles auth-defaults:auth=radius: ... radius:\ :auth=radius:\ :radius-server=localhost:\ :radius-port=1812:\ :radius-timeout=1:\ :radius-retries=5:

    Read the article

  • Using IIS7 as a reverse proxy

    - by Eric Petroelje
    I'm setting up a server at home to host a few small websites. One of them is .NET based and needs IIS, the others are PHP based and need Apache. So, I have both IIS 7 and Apache 2.2.x installed on my server with IIS on port 80 and Apache running on port 8080. I would like to set up IIS to work as a reverse proxy, forwarding the requests for the Apache sites to port 8080 and serving the requests for the .NET site itself based on the host headers. Like this: www.mydotnetsite.com/* -> IIS -> serve from IIS www.myapachesite.com/* -> IIS -> forward to apache on port 8080 www.myothersite.com/* -> IIS -> forward to apache on port 8080 I did a bit of googling and it seemed like the Application Request Routing feature would do what I needed, but I can't seem to get it to work the way I want it to. I can get it to forward ALL traffic to the Apache server and I can get it to forward traffic with a specific URL pattern to the Apache server, but I can't seem to get it to forward based on the host headers (e.g. "forward all requests for www.apachesite.com - localhost:8080") So the question is, how would I go about configuring ARR to do this? Or do I need a different tool? I'm also open to using Apache as the reverse proxy and forwarding the .NET site requests to IIS instead if that's easier (running Apache on port 80 and IIS on 8080).

    Read the article

  • Xen PV packet loss

    - by Delphinator
    I'm having some serious issues with packetloss with one of my servers. This server is a somewhat old (P4-era) machine running Debian Squeeze and Xen 4.0. There are two domUs running on it (both also Debian Squeeze), one gateway and a fileserver. Unfortunatly the processor has no virtualization extensions, therefore only PV can be used. While investigating why our network seems to be slower than it should I found some pretty bad packet loss (~25%). After further investigation and several experiments I did a measurment between the dom0 and one of the domUs: Server listening on UDP port 5001 Receiving 1470 byte datagrams UDP buffer size: 110 KByte (default) ------------------------------------------------------------ ------------------------------------------------------------ Client connecting to dom0, UDP port 5001 Sending 1470 byte datagrams UDP buffer size: 110 KByte (default) ------------------------------------------------------------ [ 3] local 192.168.1.2(domU) port 33817 connected with 192.168.1.100(dom0) port 5001 [ 4] local 192.168.1.2(domU) port 5001 connected with 192.168.1.100(dom0) port 48606 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 46.3 MBytes 38.7 Mbits/sec [ 3] Sent 33020 datagrams [ 3] Server Report: [ 3] 0.0-10.0 sec 46.2 MBytes 38.6 Mbits/sec 0.030 ms 89/33019 (0.27%) [ 3] 0.0-10.0 sec 1 datagrams received out-of-order [ 4] 0.0-10.2 sec 43.0 MBytes 35.3 Mbits/sec 13.074 ms 11575/42256 (27%) tl;dr: 27% packet loss from dom0 to domU with 50Mbit UDP packets. Same thing happens from anywhere in the network. The problem gets better for smaller bandwidths (0.047% for 5Mbit) and worse for higher (59% for 200Mbit) ones. I did increase the CPU-weight of the dom0, there is no swapping going on, and actual networking-hardware is not involved. I never expected Xen (or anything related) to drop packets, and I'm completly clueless what to try next.

    Read the article

  • iptables forwarding to a dummy interface

    - by madinc
    Hi, I'm trying to accomplish the following: I have a box with a service listening on a dummy interface (say 172.16.0.1), udp port 5555. Now what I'd like to do is to take packets that arrive on interfaces eth0 (1.1.1.1:5555) and eth1 (2.2.2.2:5555) and forward them to the service on the dummy interface, and have replies go back to clients out the same physical interface they came in. Clients must think they're talking to 1.1.1.1:5555 or 2.2.2.2:5555. I think I need a mix of iptables rules and packet marking, plus some iproute rules (if it's possible at all). What I tried is to catch packets coming in from eth0 and eth1, udp port 5555, and mark them with 1 and 2 respectively, and --save-mark in the connmark. Then I used a DNAT to 172.16.0.1. The service seems to be getting the packets. Now I'm not sure how to do the reverse. It seems that for packets originating from the box, you can't do anything before the routing decision, but that would be the place to restore the marks, and thus make a routing decision based on those. Here's what I have so far: iptables -t mangle -A PREROUTING -d 1.1.1.1 -p udp --port 5555 -j MARK --set-mark 1 iptables -t mangle -A PREROUTING -d 2.2.2.2 -p udp --port 5555 -j MARK --set-mark 2 iptables -t mangle -A PREROUTING -d 1.1.1.1 -p udp --port 5555 -j CONNMARK --save-mark iptables -t mangle -A PREROUTING -d 2.2.2.2 -p udp --port 5555 -j CONNMARK --save-mark iptables -t nat -A PREROUTING -m mark --mark 1 -j DNAT --to-destination 172.16.0.1 iptables -t nat -A PREROUTING -m mark --mark 2 -j DNAT --to-destination 172.16.0.1 # What next? As I said, I'm not even sure it can be done. To give a bit of background, it's an old OpenVPN installation that cannot be upgraded (otherwise I'd install a recent version that supports multihoming natively). Thanks for any help.

    Read the article

  • Adding third disk as a single disk in a server with an existing RAID1

    - by slowhandsolo
    I've got a ProLiant DL360 G5 server (Fedora 13) with two SAS disks in a hardware RAID 1, working fine. Now I hot plugged another SAS disk. I'd like to configure this new hard disk out of my RAID, as a single non-RAID disk (ex. /dev/sdb). Even after rebooting the server, I can't see the new disk with "fdisk -l". It displays only my hardware RAID, but not the new disk. [root@myserver]# fdisk -l Disco /dev/cciss/c0d0: 300.0 GB, 299966445568 bytes Disposit. Inicio Comienzo Fin Bloques Id Sistema /dev/cciss/c0d0p1 * 1 126 512000 83 Linux /dev/cciss/c0d0p2 126 71798 292422656 8e Linux LVM Disco /dev/dm-0: 234.9 GB, 234881024000 bytes Disco /dev/dm-1: 10.5 GB, 10536091648 bytes Disco /dev/dm-2: 21.0 GB, 20971520000 bytes Disco /dev/dm-3: 31.5 GB, 31474057216 bytes Disco /dev/dm-4: 1577 MB, 1577058304 bytes However, I can see the new disk using the HP Array Configuration Utility CLI for Linux "hpacucli": [root@myserver]# hpacucli => controller slot=0 physicaldrive all show status physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 300 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 300 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 300 GB): OK => controller slot=0 pd all show detail Smart Array P400i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 **unassigned** physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: **Unassigned Drive** As you can see, I've got two SAS disks in a RAID 1 and the new disk as "unassigned". Is there any way to work with the new disk as another non-RAID single disk? If relevant, I want to create a new partition in my new disk, format it with mkfs and mount it, but as I can't see it with fdisk, I don't know how to do it. Thanks!

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • iperf max udp multicast performance peaking at 10Mbit/s?

    - by Tom Frey
    I'm trying to test UDP multicast throughput via iperf but it seems like it's not sending more than 10Mbit/s from my dev machine: C:\> iperf -c 224.0.166.111 -u -T 1 -t 100 -i 1 -b 1000000000 ------------------------------------------------------------ Client connecting to 224.0.166.111, UDP port 5001 Sending 1470 byte datagrams Setting multicast TTL to 1 UDP buffer size: 8.00 KByte (default) ------------------------------------------------------------ [156] local 192.168.1.99 port 49693 connected with 224.0.166.111 port 5001 [ ID] Interval Transfer Bandwidth [156] 0.0- 1.0 sec 1.22 MBytes 10.2 Mbits/sec [156] 1.0- 2.0 sec 1.14 MBytes 9.57 Mbits/sec [156] 2.0- 3.0 sec 1.14 MBytes 9.55 Mbits/sec [156] 3.0- 4.0 sec 1.14 MBytes 9.56 Mbits/sec [156] 4.0- 5.0 sec 1.14 MBytes 9.56 Mbits/sec [156] 5.0- 6.0 sec 1.15 MBytes 9.62 Mbits/sec [156] 6.0- 7.0 sec 1.14 MBytes 9.53 Mbits/sec When I run it on another server, I'm getting ~80Mbit/s which is quite a bit better but still not anywhere near the 1Gbps limits that I should be getting? C:\> iperf -c 224.0.166.111 -u -T 1 -t 100 -i 1 -b 1000000000 ------------------------------------------------------------ Client connecting to 224.0.166.111, UDP port 5001 Sending 1470 byte datagrams Setting multicast TTL to 1 UDP buffer size: 8.00 KByte (default) ------------------------------------------------------------ [180] local 10.0.101.102 port 51559 connected with 224.0.166.111 port 5001 [ ID] Interval Transfer Bandwidth [180] 0.0- 1.0 sec 8.60 MBytes 72.1 Mbits/sec [180] 1.0- 2.0 sec 8.73 MBytes 73.2 Mbits/sec [180] 2.0- 3.0 sec 8.76 MBytes 73.5 Mbits/sec [180] 3.0- 4.0 sec 9.58 MBytes 80.3 Mbits/sec [180] 4.0- 5.0 sec 9.95 MBytes 83.4 Mbits/sec [180] 5.0- 6.0 sec 10.5 MBytes 87.9 Mbits/sec [180] 6.0- 7.0 sec 10.9 MBytes 91.1 Mbits/sec [180] 7.0- 8.0 sec 11.2 MBytes 94.0 Mbits/sec Anybody has any idea why this is not achieving close to link limits (1Gbps)? Thanks, Tom

    Read the article

< Previous Page | 116 117 118 119 120 121 122 123 124 125 126 127  | Next Page >