  • How to increase the speed between two external hard drives on my laptop?

    - by Roman
    Hello, I own Sony Vaio Z laptop with two external USB ports. It's quite new and has USB 2.0 support. I'm using Vista x64 on it. I also have two external usb hard drives, Iomega 500GB and WD for 1TB. Every hard drive has USB 2.0 support. I connect two devices to my laptop and trying to copy date from one hard drive to another. But it takes a lot of time! The speed is about 15 Megabytes per second. I have to wait toooooo long to copy all the information from one hard drive to another. When I try to copy information from my internal (SSD) hard drive, it works fine for both external drives. The speed is very high and it shows me something about 100 Megabytes per second. It makes me feel that USB 2.0 is OK on both drives. But when I'm trying to copy from one external drive to another external, I still get very low speed. I checked out Device Manager and here is the settings I have: (sorry, can't upload image because of my rating, check this url: http://picbite.com/image/122073daljo/ ) I think it's because two of my external drives use the same USB 2.0 controller. Is there any way to make it work faster? Is it possible to move one of my USB ports to other USB 2.0 controller? Or is there any software which can help me to automate copying all the files thru my internal drive? I have only about 3 gigabytes free space on internal drive and it's quite difficult to move manually every file from one hard drive to internal and then again to another internal.

    Read the article

  • Copy past speed very slow for a large number of tiny files on Windows but not on linux

    - by Arno2501
    I've got this folder which contains 15'000 of tiny images (around 400 bytes each). If I copy past this folder on my laptop (Windows 7, i7 latest gen, superfast ssd) it takes about 30 seconds (yes for 7 megs !!!) the average transfer rate is 400 KBytes / second which is so slow. I mean my usual transfer rate is more like hundreds of MBytes per second !!! I get the same problem on my servers (Windows 2003, 2008 /r2) and on every Windows box that I could get my hands on. On the other hand if I do the same on a linux box (debian base, Ext3 FS) (which runs on the same SAN than all the windows servers I've tested) It's nearly instantaneous !!! I'm pretty sure the size / number of the files may stress such filesystem more than another but such differences !? Why is that ? Why is it so slow on the windows boxes (more that 30 sec for 7 MB) and so fast on the linux ones (one sec or so) (I mean this was not a hardlink that I've created it was a true copy). Is it a normal behaviour or something unusual ?

    Read the article

  • MySQL getting stuck, eating up disk i/o

    - by bonez05
    Hi all, Using mySQL 5.0.51 on Solaris . At intermittent times it looks like MySQL is getting 'stuck' . The disk usage on the server spikes to 98% busy from reads. I used dtrace (specifically DTrace toolkit - iosnoop) to track down what processes was using all the reads. Mysql was calling tablename.TDM hundreds of times per second. There was no more than average load on the webserver that could account for this. There were no cronjobs running, and no other utilities like mysqldump or anything. It is a master / slave replication setup. As a jury-rigged fix, I altered the mysql table from 'tablename' to 'tablename2' and then back to 'tablename' This fixed the problem temporarily, and "unsticks" mysql. The disk usage goes back down and dtrace is no longer showing hundreds of reads to 'tablename.TDM' / second. A couple ideas I had are: 1. MySQL version bug 2. Infinite loop somewhere in my application (which i'm not sure how likely this is) 3. ?? Has anybody seen this before or have any insight? Thanks

    Read the article

  • My Reverse DNS PTR record seems to be right, but I'm still getting bouncing email

    - by johnbr
    Hello, I have a service (statusme.com) where I let people know (for example) that their kid's soccer games are cancelled because of bad weather. We send out emails to the people who have registered. I have a second server as a backup, (vps.statusme.com) and I've set up the application to send some of the email through the second server. But I'm getting complaints from various recipient SMTP servers that the email is considered spam. So I did some investigating, and it appears that they think my reverse DNS record isn't correct. But when I look at it via various rDNS websites and instructions I found elsewhere on ServerFault, everything looks correct: jb$ host -t a vps.statusme.com 8.8.8.8 Using domain server: Name: 8.8.8.8 Address: 8.8.8.8#53 Aliases: vps.statusme.com has address 66.84.8.246 jb$ host -t ptr 246.8.84.66.in-addr.arpa 8.8.8.8 Using domain server: Name: 8.8.8.8 Address: 8.8.8.8#53 Aliases: 246.8.84.66.in-addr.arpa domain name pointer vps.statusme.com. I'm confused about what I'm doing wrong. Thanks for any suggestions.

    Read the article

  • Why does clicking on Windows 7 Printer Properties Result In Driver Not Installed?

    - by octopusgrabbus
    The question I need to ask is has anyone heard of getting a "driver not installed" error when clicking on a printer's properties on Windows 7, and is there a workaround? Here are the details of the problem. One of our users has a Windows 7 desktop, and an HP LaserJet 4050 T connected to via a parallel-to-usb converter. The PLC5 universal driver was installed for series 4050 printers. I needed to install the PLC 6 driver, which completed successfully. The user is an administrator of the system, and I was prompted to and accepted running as Administrator to install the driver. After the install, I went to see the 4050's properties and was prompted that the PLC6 driver was not installed. I believe the PLC6 driver was installed, because the PLC5 driver resulted in receiving an official HP error page indicating the printer was "not set up for collating" as the second page of printing two copies of a one page email. This problem did not occur with the PLC 6 driver. Oddly enough, setting back to PLC5 produced the same error about the PLC5 driver not being installed. I ignored/dismissed the error box (did not re-install the driver), and reproduced the error, with the second page being the HP not set up for collating error page. Any thoughts on what is causing this and how to clear it would be appreciated. The closest fix I could find was on a Microsoft tech page, and they had me clear winsock out of a Administrator run command line, followed by a reboot. That did not fix the problem. I have also found this http://social.technet.microsoft.com/Forums/windowsserver/en-US/5101195b-3aca-4699-9a06-db4578614e2d/changing-driver-results-in-printer-driver-is-not-installed-error-on-server-2008?forum=winserverprint and will look into trying some of these suggestions, which appear to me to be a "shotgun" approach to fixing the problem.

    Read the article

  • Scaling databases with cheap SSD hard drives

    - by Dennis Kashkin
    Hey guys! I hope that many of you are working with high traffic database-driven websites, and chances are that your main scalability issues are in the database. I noticed a couple of things lately: Most large databases require a team of DBAs in order to scale. They constantly struggle with limitations of hard drives and end up with very expensive solutions (SANs or large RAIDs, frequent maintenance windows for defragging and repartitioning, etc.) The actual annual cost of maintaining such databases is in $100K-$1M range which is too steep for me :) Finally, we got several companies like Intel, Samsung, FusionIO, etc. that just started selling extremely fast yet affordable SSD hard drives based on SLC Flash technology. These drives are 100 times faster in random read/writes than the best spinning hard drives on the market (up to 50,000 random writes per second). Their seek time is pretty much zero, so the cost of random I/O is the same as sequential I/O, which is awesome for databases. These SSD drives cost around $10-$20 per gigabyte, and they are relatively small (64GB). So, there seems to be an opportunity to avoid the HUGE costs of scaling databases the traditional way by simply building a big enough RAID 5 array of SSD drives (which would cost only a few thousand dollars). Then we don't care if the database file is fragmented, and we can afford 100 times more disk writes per second without having to spread the database across 100 spindles. . Is anybody else interested in this? I've been testing a few SSD drives and can share my results. If anybody on this site has already solved their I/O bottleneck with SSDs, I would love to hear your war stories! PS. I know that there are plenty of expensive solutions out there that help with scalability, for example the time proven RAM-based SANs. I want to be clear that even $50K is too expensive for my project. I have to find a solution that costs no more than $10K and does not take much time to implement.

    Read the article

  • Doing arithmetic and passing it to the next command

    - by neurolysis
    I know how to do this in /bin/sh, but I'm struggling a bit in Windows. I know you can do arithmetic on 32-bit signed integers with SET /a 2+2 4 But how do I pass this to the next command? For example, the process I want to perform is as follows. Consumer editions of Windows have no native automated sleep function (I believe?) -- the best way to perform a sleep is to use PING in association with the -n switch to get that many seconds, minus one, of sleep. The following command is effective for a silent sleep: PING localhost -n 3 > NUL But I want to alias this into a sleep command. I'd like to have it elegant so that you enter the actual number of seconds you want to sleep after the command, right now I can do DOSKEY SLEEP=PING 127.0.0.1 -n $1 > NUL Which works, but it's always 1 second less than your input, so if you wanted to sleep for one second you would have to use the command SLEEP 2. That's not exactly ideal. Is there some way for me to pass the arithmetic of $1+1 and pass it on to the next command in Windows? I assume there is some way of using STDOUT...

    Read the article

  • How to create a new background process in a KSH "while read" loop?

    - by yael
    The following test script has a problem. When I add the line (sleep 5 ) & in the script then the "while read" loop does not read all lines from the file, but only prints the first line. But when I remove the ( sleep 5 ) & from the script, then the script prints all lines as defined in the file. Why the ( sleep 5 ) & causes this? And how to solve the problem? I want to create a new process (for which the sleep is just an example) in the while loop: $ more test #!/bin/ksh while read -r line ; do echo Read a line: echo $line ( sleep 5 )& RESULT=$! echo Started background sleep with process id $RESULT sleep 1 echo Slept for a second kill $RESULT echo Killed background sleep with process id $RESULT done < file echo Completed On my Linux, when using the following contents of file: $ more file 123 aaa 234 bbb 556 ccc ...running ./test just gives me: Read a line: 123 aaa Started background sleep with process id 4181 Slept for a second Killed background sleep with process id 4181 Completed

    Read the article

  • Move OS from RAID5 array to RAID 1 arrays

    - by Antoine
    I want to give a last boost to my old ProLiant ML350 G5 server which just needs to be reliable for a few more year only ! With a defined budget of about 1500$ (I do not have more), i plan to replace the CPU (+ adding a second one), the battery cache of my raid controller (E200i), double the RAM, and change all hard drives. I have 7 HDD (SAS 10krpm, 72Gb) + 1 spare in RAID5, and my system is all FULL (no empty tray, full disks). in my current RAID5 array, I have 2 partitions: - 1 OS partition, 20Gb - 1 data partition, 350 Gb I plan to replace these 8 disks with : - 2 x 300Gb SAS 15krpm in RAID 1 (= 1 partition for OS) - 2 x 2Tb SATA 7.2krpm in RAID 1 (= 1 partition for DATA) My biggest constraint is that I have only 01 day to upgrade my server. Therefore, I'm looking for cloning all my files (OS + data partition) to my new arrays, i.e : - the OS partition shall be cloned to the RAID1 "2x300Gb array" - the data partition shall be cloned to the RAID1 "2x2Tb array" My second problem is that I need to physically remove all the old hard drives before inserting the new ones. I'm running Windows Server 2003 R2, and even if MS support will expire soon, I cannot buy a new licence and spent time in configuration. Obviously, with 1500$, I cannot also buy a new server that I could start configuring from now ! Thought about ASR (NTBackup), but I have no floppy drive (and do not really want to invest in one !) Thought about a clonezilla clone, and read this interesting link : Windows Server 2003 - move C: partition to a new SAS disk , but i'm not so confident in using Clonezilla with RAID5. What should be the best option to quickly and easily (if possible!) "copy/paste" my OS (so no need to reinstall and reconfigure all) and DATA / programs / services, etc... ? Thanks for your comments

    Read the article

  • poor performance when deleteing many files

    - by choppy
    I've got two machines: The first is IBM Blade with 24 cores 96GB RAM and single local hard drive with 278GB divided to 4 partitions: 1. c: - 40GB; 3GB free 2. d: - 40GB; 37GB free 3. e: - 198322GB; 198.1 free 4. 100MB (EFI system Partition) Formatted with GPT The other is pizza server with 4 cores 8GB RAM and single local hard drive with 273GB divided to 3 partitions: 1. c: - 136.81; 20GB free 2. d: - 88.74GB; 87.91 free 3. e: - 47.85GB; 46.91 free Formatted with MBR I have two scripts, the first creates 20,000 files in one directory, each file size is 192KB, the second delete the folder (recursive) and prints how much time it toke to delete all files. The problem is on the first server (blade) it takes about 2 minutes to delete all 20,000 files while on the second (pizza) it takes about 4 seconds!? Both servers have clean windows server 2008R2 with no special application running on background. Any ideas what is going on?

    Read the article

  • Where do vendors publish internal transfer rates of HDDs?

    - by red888
    So I've started to dig into storage fundamentals and found that in order to calculate the IOPS of a HDD you need to know the internal transfer rate of the drive (time it takes data to move from the platters to internal disk's cache). I went on newegg and even a few vendor sites and could not find this info published for any HDDs. Is it sometimes called something else? Take this link to a seagate HDD for instance. Nowhere do I see "internal transfer rate", but I do see something called "Sustained Data Rate OD"- is that the same thing? Just so you know where I'm getting this info (Book: "Information Storage and Management Storing, Managing..."): Consider an example with the following specifications provided for a disk: The average seek time is 5 ms in a random I/O environment; therefore, T = 5 ms. Disk rotation speed of 15,000 revolutions per minute or 250 revolutions per second — from which rotational latency (L) can be determined, which is one-half of the time taken for a full rotation or L = (0.5/250 rps expressed in ms). 40 MB/s internal data transfer rate, from which the internal transfer time (X) is derived based on the block size of the I/O — for example, an I/O with a block size of 32 KB; therefore X = 32 KB/40 MB. Consequently, the time taken by the I/O controller to serve an I/O of block size 32 KB is (TS) = 5 ms + (0.5/250) + 32 KB/40 MB = 7.8 ms. Therefore, the maximum number of I/Os serviced per second or IOPS is (1/TS) = 1/(7.8 × 10^-3) = 128 IOPS.

    Read the article

  • SQL 2008 R2 replication error: The process could not connect to Distributor

    - by Lance Lefebure
    I have two servers running SQL 2008 R2 Standard, each with an instance named "MAIN". I have a small test database on my primary server (one table, 13 rows) that I want to replicate to a second server as a proof-of-concept for some larger databases that I want to replicate. I set up the primary server to be a publisher and distributor, and set the database to do transactional replication. I copied the data to the second server via a backup/restore, not via a snapshot (which I'll have to do with the larger databases due to database size and limited bandwidth). I followed the instructions here: http://gnawgnu.blogspot.com/2009/11/sql-2008-transactional-replication-and.html Now on the subscriber, I go under Replication / Local Subscriptions / Right click / Properties on my subscription to the DB. The status of the last synchronization shows a status of: "The process could not connect to Distributor 'PRIMARYSERVER\MAIN'." Data IS replicating from the primary to the secondary. Any record I add on the primary shows up on the secondary server within seconds. Is the Distributor part of the Snapshot system that I'm not using, or is it part of the transaction replication stuff? Thanks, Lance

    Read the article

  • IPTABLE & IP-routed netwok solution for HOST net and VM's subnet

    - by Daniel
    I've got ProxmoxVE2.1 ruled KVM node on Debian and bunch of VM's guests machine. That is how my networking looks like: # network interface settings auto lo iface lo inet loopback # device: eth0 auto eth0 iface eth0 inet static address 175.219.59.209 gateway 175.219.59.193 netmask 255.255.255.224 post-up echo 1 > /proc/sys/net/ipv4/conf/eth0/proxy_arp And I've got two working subnet solution auto vmbr0 iface vmbr0 inet static address 10.10.0.1 netmask 255.255.0.0 bridge_ports none bridge_stp off bridge_fd 0 post-up ip route add 10.10.0.1/24 dev vmbr0 This way I can reach internet, to resolve outside hosts, update and download everything I need but can't reach one guest VM out of any other VM's inside my network. The second solution allows me to communicate between VM's: auto vmbr1 iface vmbr1 inet static address 10.10.0.1 netmask 255.255.255.0 bridge_ports none bridge_stp off bridge_fd 0 post-up echo 1 > /proc/sys/net/ipv4/ip_forward post-up iptables -t nat -A POSTROUTING -s '10.10.0.0/24' -o vmbr1 -j MASQUERADE post-down iptables -t nat -D POSTROUTING -s '10.10.0.0/24' -o vmbr1 -j MASQUERADE I can even NAT internal addresses: -t nat -I PREROUTING -p tcp --dport 789 -j DNAT --to-destination 10.10.0.220:345 My inexperienced mind is ready to double VM's net adapters: one for the first solution and another - for second (with slightly different adresses) but I'm pretty sure that it's a dumb way to resolve the problem and everything can be resolved via iptables/ip route rules that I can't create. I've tried a dozen of "wizard manuals" and "howto's" to mix both solution but without success. Looking for an advice (and good reading links for networking begginers).

    Read the article

  • Why do I need to set up Autologon values in registry twice before it works and can i fix this?

    - by jJack
    Background: As part an automated testing suite I am building, I need to set up Autologon on my virtual machines 'on demand'. By on demand, I mean that I don't want to necessarily pre-configure my VM or any snapshot to have Autologon set up already, for security reasons and also a huge business case. My solution so far: I'm copying a script to the guest machine and then using Sysinternals PsExec to execute it. The script is: reg add "hklm\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon" /f /v DefaultUserName /t REG_SZ /d myusername reg add "hklm\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon" /f /v DefaultPassword /t REG_SZ /d myfakepassword reg add "hklm\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon" /f /v DefaultDomainName /t REG_SZ /d mydomain reg add "hklm\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon" /f /v ForceAutoLogon /t REG_SZ /d 1 reg add "hklm\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon" /f /v AutoAdminLogon /t REG_SZ /d 1 reg add "hklm\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon\AutoLogonChecked" /f /ve /d 1 Note: I don't believe AutoLogonChecked is required for machines post Windows 2000 but I'm doing it just in case for now. Maybe ForceAutoLogon isn't either, not sure yet. The Problem: I see PsExec executes this properly and all the values are in the registry, however when I restart the machine, the user isn't automatically logged on...When I run this a second time then restart the machine, the user is finally logged on. A diff between the registry states shows that the first time I run this, it is missing both the "1" for AutoAdminLogon, and also the DefaultPassword key. The second time I execute it, these values are correctly intact as I intended. So, what is going on here? Is this expected? This post claims in the end that it really all just works (the problem was that a logoff script was setting off the values). Doesn't seem to work for me however.

    Read the article

  • DRBD stacked resources: recovering from failure

    - by Marcus Downing
    We're running a stacked four-node DRBD setup like this: A --> B | | v v C D This means three DRBD resources running across these four servers. Servers A and B are Xen hosts running VMs, while servers C and D are for backups. A is in the same datacentre as C. From server A to server C, in the first datacentre, using protocol B From server B to server D, in the second datacentre, using protocol B From server A to server B, different datacentres, stacked resource using protocol A First question: booting a stacked resource We haven't got any vital data running on this setup yet - we're still making sure it works first. This means simulating power cuts, network outages etc and seeing what steps we need to recover. When we pull the power out of server A, both resources go down; it attempts to bring them back up at next boot. However, it only succeeds at bringing up the lower-level resource, A-C. The stacked resource A-B doesn't even try to connect, presumably because it can't find the device until it's a connected primary on the lower level. So if anything goes wrong we need to manually log in and bring that resource up, then start the virtual machine on top of it. Second question: setting the primary of a stacked resource Our lower-level resources are configured so that the right one is considered primary: resource test-AC { on A { ... } on C { ... } startup { become-primary-on A; } } But I don't see any way to do the same with a stacked resource, as the following isn't a valid config: resource test-AB { stacked-on-top-of test-AC { ... } stacked-on-top-of test-BD { ... } startup { become-primary-on test-AC; } } This too means that recovering from a failure requires manual intervention. Is there no way to set the automatic primary for a stacked resource?

    Read the article

  • How do I set up dual monitors on Kubuntu 10.04 using the latest nVidia drivers with a 9800M video ca

    - by NoCatharsis
    I'm a Linux newb so please try to keep the lingo low-key. I installed the latest nVidia drivers on my laptop using the 9800M card. The laptop is a Gateway P-7805u and I'm connected to the second monitor using VGA. Also, before installing the nVidia drivers (and just using the basic drivers included with Kubuntu 10.04), basic dual monitor support worked, except I could not enable compositing features for some reason. So I thought the proprietary drivers would fix this. Several issues have arisen since installation: 1) I've clicked through all of the display settings to activate the second screen with absolutely no change. 2) When I try to apply settings and Save Configuration as the nVidia help suggests, I am told that I cannot save to the X.conf file. I assume this is due to innate permissions on my user settings, which I have no idea how to properly configure. 3) I have no idea where to go from here, as most of the fixes I found online involve Linux syntax and verbiage, to which I'm totally clueless after spending over half my life with Windows.

    Read the article

  • Windows7 corrupted profile - prevention exists?

    - by Radek
    I have dedicated Windows7 (not on domain) virtual machine for overnight automation testing. Some commands (mySQLdump, tscon.exe) must be run under administrator account. Last week administrator account's profile was corrupted. I fixed it by renaming it in the registry and logging in as administrator. And today it is corrupted again. I use administrator account only to run above commands via runas. Also the computer is restarted via cmd - shutdown command - quite often. Especially every night before automation testing starts. I checked the comp for viruses - did full scan using avast although I believed that the comp is clean. Any idea how to prevent the profile to get corrupted again? update So the first log entry in event log is today from 1.15am and one of my scripts ran runas command as administrator exactly at 1.15am. It was second time that runas war executed though after the testing started. The same happened second day in a row. Before the testing starts I need to copy one file that is locked. So I run handle.exe from runas to unlock it. That is what I think causing the profile to get corrupted. I am not able to reproduce it by myself. The message from event viewer is Windows cannot load the locally stored profile. Possible causes of this error include insufficient security rights or a corrupt local profile. DETAIL – The process cannot access the file because it is being used by another process.

    Read the article

  • What exactly is a Deamon ? ( how to run a root command from apache binded script that uses www-data user )?

    - by user224235
    I am trying to run this command from WSGI script service httpd restart The problem is this command can only be run by root and apache uses the www-data user. it has been said the solution is to use a Deamon Process i suppose the idea is to send the command to a file that will be executed by a script that is considered "root" user.. its difficult to understand why they would call this a Deamon Process and try to scare me. Perhaps it should have been called : proxy process when i got the idea that this was a proxy process.. i thought about adding a line to /var/spool/cron/root that way the cron would execute the command for me. but of course this means i have to get the system time and then add 1 second to it and then add it to that line so cron would execute the command for me as root but my script demands an output instantly. so i suppose i need to create a DEAMON PROCESS that works like the cron. in other words it is a bash file that will execute the command in a plain file.. but will this DEAMON PROCESS be running a while command 24/7 every second ? would that not waste resources ? it only needs to activate itself to check for a command to execute when there is a command to be executed. i mean in PHP and other programming languages.. running a while statement when there is nothing to be executed could waste resources of the server.. so why should a deamon process constantly be listening for anything. i only want it to listen and execute when it is needed. i do not need a process that is constantly listening.

    Read the article

  • Remote Desktop fails after VPN connection

    - by Samet Sorgut
    The local computer (comp 1) is connected to a remote computer (comp 2) with Remote Desktop. On the remote computer (comp 2), I try to establish an VPN connection to a different remote computer (comp 3). Once I try to establish the VPN connection from the remote computer (comp 2) to the second remote computer (comp 3), Remote Desktop freezes on comp 1. It is not possible to connect to comp 2 again via Remote Desktop. What can be done to connect to this remote computer (comp 2) after it establishes a VPN connection? The only thing that comes to my mind is to install a second NIC and configure Remote Desktop to accept connection from this NIC while VPN is working from the other... What do you suggest? EDIT: I want to use the internet connection of the VPN, so all traffic should go over the VPN but still RDP working. My IP: 100.0.0.1 The IP where I'm connecting via RDP: 200.0.0.20 (Mask: 255.255.255.192, Gateway: 200.0.0.193) Where the 200.0.0.1 connects to VPN the IP of the VPN is: 65.254.61.250 Will routing like this help (Command is issued in 200.0.0.20, the RDP location): route ADD 65.254.61.250 MASK 255.255.255.192 200.0.0.193 Couldn't add gives the error: The route addition failed: The parameter is incorrect. I tried before connecting to VPN.

    Read the article

  • Missing Boot Manager in Vista

    - by Selase
    I am in really deep trouble here and would need advice. A message just pop up on my screen and I had to restart my laptop. Upon restarting the Boot Manager got corrupted. I am running Windows Vista 32 bit by the way. I got onto Google with a friend's PC and found two basic ways of fixing it. The first one that requires Windows to automatically fix it using Startup repair ends up with the error message: Startup REpair cannot repair this computer automatically The second option that requires me to rebuild the BCD scans my system and finds the operating system on drive D:\Windows which I believe should be C:. If I hit Y(yes) for the rebuild process to take place I get the message The required system device cannot be found I then try the second option which requires me to recreate the BCD Store. It ends up with an error message that says: The store export operation has failed. The requested system device cannot be found Proceeding from there is meaningless since the system device cannot be found. I somehow believe the device cannot be found because it's identifying the Windows installation on D: instead of C: but how to change that I have no idea. I don't know how it happens to identify an operating system on D: when there's none there. How do I go about fixing the Boot Manager? I have very important files on my system and can't afford to reinstall Windows. I really need to fix this.

    Read the article

  • logfile deleted on Oracle database how to re-create it?

    - by Daniel
    for my database assignment we were looking into 'database corruption' and I was asked to delete the second redo log file which I have done with the command: rm log02a.rdo this was in the $HOME/ORADATA/u03 directory. Now I started up my database using startup pfile=$PFILE nomount then I mounted it using the command alter database mount; now when I try to open it alter database open; it gives me the error: ORA-03113: end-of-file on communication channel Process ID: 22125 Session ID: 25 Serial number: 1 I am assuming this is because the second redo log file is missing. There is still log01a.rdo, but not the one I have deleted. How can I go about recovering this now so that I can open my database again? I have looked into the database created scripts, and it specified the log02a.rdo file to be size 10M and part of group 2. If I do select group#, member from v$logfile; I get: 1 /oradata/student_db/user06/ORADATA/u03/log01a.rdo 2 /oradata/student_db/user06/ORADATA/u03/log02a.rdo 3 /oradata/student_db/user06/ORADATA/u03/log03a.rdo 4 /oradata/student_db/user06/ORADATA/u03/log04a.rdo So it is part of group 2. If I try to add the log02a.rdo file again "already part of the database". If I drop group 2 and then add it again with these commands: ALTER DATABASE ADD LOGFILE GROUP 2 ('$HOME/ORADATA/u03/log02a.rdo') SIZE 10M; Nothing. Supposedly alters the database, but it still won't start up. Any ideas what I can do to re-create this and be able to open my database again?

    Read the article

  • Recommended Win2k8 Server software to fix my RAID-0 issue

    - by Jason Kealey
    I'm running an Asus P6T V2 Deluxe. It has six SATA ports and supports onboard RAID. I am using two of those ports for a RAID0 array of 1.5TB Seagate drives using the onboard RAID controller. One of them is giving me SMART warnings and I want to preemptively replace it. I pulled out two other 1.5TB drives from another computer and am ready to use one or both, if necessary. I can't run any SMART diagnostic software from within Windows because it only sees the hardware RAID-0 array, not each individual drive. The first thing I tried was a slow sector-by-sector copy using a free tool called EASEUS Disk Copy. Used the bootdisk, copied (took like 16 hours), unplugged the defective drive and plugged the new one in its place. The motherboard didn't recognize the new drive as being part of the known setup, so it did not want to boot. The second thing I tried was using other software (I forget the name) to copy the partition from within Windows. The first software failed because I had a server operating system. I found another software (I forget the name) which supported a server OS and did a partition copy onto the new drive. This seemed to work and the OS started to boot, but blue screened and started a reboot cycle. I'm assuming the software I was using was no good as it was trying to copy the boot disk while it was in use. I am looking for recommendations on what software to use to fix my problem without doing a re-install. Everything is backed up but my computer works fine and I'd like to avoid re-installation when possible. However, my system would be back up now if I had just started over on a second RAID array. :)

    Read the article

  • Weird glitches on Intel iGPU

    - by FrederikVds
    I have a weird problem that I can't manage to describe in one word, so I'm having trouble searching for a solution. My monitors sometimes go black for a tenth of a second. Other times, they show the image shifted a few centimeters to the left or to the right. This happens on both of my monitors, but not necessarily at the same time. I would say it happens about once a minute, unless under heavy load, in which case it can happen every second or so. Interestingly, heavy CPU/memory usage can also cause this, not just heavy GPU usage. This only happens when they are both at 1920x1080, not when one of them, or both, are at a lower resolution. It also happens when they are in mirrored mode instead of extended desktop mode. My GPU is obviously not at full clock speed most of the time: this happens at 350 MHz as well as at 1200 MHz. So it doesn't seem like a matter of too little performance. I'm not seeing any traditional artefacts, even when I use MSI Kombustor, only this kind of full-screen glitches. CPU stressing software isn't reporting any issues either. I'm thinking maybe the connection between my CPU and my PCH isn't fast enough, but I can't find anyone with the same problem to confirm that. I'd rather not invest in a discrete GPU without being certain it will fix something. Does anyone know how to search for this, or even better, does anyone have a solution? My full specs are below. Thanks in advance! Specs: ASUS P8Z77-M Intel Core i5-3570K (with Intel HD 4000 Graphics) 2x4 GB AMD Performance Edition memory Corsair Force 3 Series Rev. B 120GB SSD Maxtor 200GB HD Lite-On DVD-RW Antec 350 Watt PSU 64-bit Windows 7 Professional 2x Iiyama ProLite E2208HDS display

    Read the article

  • Computer won't start after installing new video card

    - by Vercas
    So, 1 year and 340 days ago I bought a desktop computer. Since then, it has served me well. But lately, I wanted an upgrade, so I bought a new video card. I documented myself about the compatibility, and it is okay. So I opened the case, cleaned up that... dust elemental living inside of it. Unscrewed the plastic thingie on the outside to unscrew the old video card. Because of the stupid arrangement of the ports, I had to unscrew the motherboard to unplug it. So I unscrewed it, removed the old card, put in the new one, moved the motherboard back, screwed it back in, screwed the video card on the holder... thingie, and screwed the plastic thingie back in. Everything went smoothly, nothing had to be forced in/out. I connected the external power supply, closed the computer case, put the tower back in it's place and all the cables back in. When I pressed the power button, the LED turned... some color I can't distinguish. It stayed that way for a second, and then it went off. I tried a bunch of things, including permuting the external power supply arrangement (1 connection, 2 connections and no connections), with no success. And here are some of the specifications: Motherboard manufacturer: Asrock Processor: AMD Athlon II X2 3.0 GHz RAM: 2 x 2GB (had only 1 initially, bought the second plate a bit later) OLD video card: AMD Radeon HD 5450 NEW video card: Gigabyte nVidia GeForce GTX 650 GPU, 1GB GDDR5 128bit PCI-E, Dual-link DVI-Dx2 / HDMI / D-Sub Power supply: 450W + all the requirements I managed to find on the internet are met (+12V 18A or something) More specific information is stored... On that computer. If required, I may open the case again and read the stickers to find more specific information. I can also provide photos if necessary. Any ideas? Suggestions? Something? :|

    Read the article

  • Western Digital HDD now freezes my BIOS when loading the video card!

    - by Vercas
    After I have successively and successfully installed 3 Windows XP's on the same partition (Don't ask why...), I restarted my computer again and the BIOS just froze when it loaded the video card. Together with my uncle, we tracked down the problem and found out it's the HDD's fault. We tried booting without the HDD and it worked! (No other HDD (I have only one) but with a Ubuntu Live CD in.) We tried the HDD with a different data bus (It was from an identical computer) but that one didn't let my BIOS recognize the HDD. We also put the HDD in another computer as the second HDD and it DID recognize it but Windows XP kept saying it cannot install a driver and that it installed successfully. Happily, I have managed to backup some of my most important files in that other computer. The following is a list of tests that we have run. With the HDD Original data bus Original computer Result: BIOS freezes WITHOUT the HDD Original data bus Original computer Result: Everything works just fine! With the HDD ANOTHER data bus Original computer Result: Cannot see the HDD With the HDD Original data bus ANOTHER computer Result: It worked! With the HDD ANOTHER data bus ANOTHER computer Result: It worked! During the tests, we had only two data buses and two computers. (each data bus from it's own computer) Strange thing is that the second data bus cannot let the BIOS see the HDD in my computer but works just fine with the other computer. I beg you to help me! I have my most important data on that HDD and I really cannot afford to buy another decent IDE HDD now!

    Read the article