Search Results

Search found 12038 results on 482 pages for 'controller actions'.

Page 124/482 | < Previous Page | 120 121 122 123 124 125 126 127 128 129 130 131  | Next Page >

  • 3Ware 9650SE RAID-6, two degraded drives, one ECC, rebuild stuck

    - by cswingle
    This morning I came in the office to discover that two of the drives on a RAID-6, 3ware 9650SE controller were marked as degraded and it was rebuilding the array. After getting to about 4%, it got ECC errors on a third drive (this may have happened when I attempted to access the filesystem on this RAID and got I/O errors from the controller). Now I'm in this state: > /c2/u1 show Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB) ------------------------------------------------------------------------ u1 RAID-6 REBUILDING 4%(A) - - 64K 7450.5 u1-0 DISK OK - - p5 - 931.312 u1-1 DISK OK - - p2 - 931.312 u1-2 DISK OK - - p1 - 931.312 u1-3 DISK OK - - p4 - 931.312 u1-4 DISK OK - - p11 - 931.312 u1-5 DISK DEGRADED - - p6 - 931.312 u1-6 DISK OK - - p7 - 931.312 u1-7 DISK DEGRADED - - p3 - 931.312 u1-8 DISK WARNING - - p9 - 931.312 u1-9 DISK OK - - p10 - 931.312 u1/v0 Volume - - - - - 7450.5 Examining the SMART data on the three drives in question, the two that are DEGRADED are in good shape (PASSED without any Current_Pending_Sector or Offline_Uncorrectable errors), but the drive listed as WARNING has 24 uncorrectable sectors. And, the "rebuild" has been stuck at 4% for ten hours now. So: How do I get it to start actually rebuilding? This particular controller doesn't appear to support /c2/u1 resume rebuild, and the only rebuild command that appears to be an option is one that wants to know what disk to add (/c2/u1 start rebuild disk=<p:-p...> [ignoreECC] according to the help). I have two hot spares in the server, and I'm happy to engage them, but I don't understand what it would do with that information in the current state it's in. Can I pull out the drive that is demonstrably failing (the WARNING drive), when I have two DEGRADED drives in a RAID-6? It seems to me that the best scenario would be for me to pull the WARNING drive and tell it to use one of my hot spares in the rebuild. But won't I kill the thing by pulling a "good" drive in a RAID-6 with two DEGRADED drives? Finally, I've seen reference in other posts to a bad bug in this controller that causes good drives to be marked as bad and that upgrading the firmware may help. Is flashing the firmware a risky operation given the situation? Is it likely to help or hurt wrt the rebuilding-but-stuck-at-4% RAID? Am I experiencing this bug in action? Advice outside the spiritual would be much appreciated. Thanks.

    Read the article

  • Virtualmin "Command to run after making changes to a server" differentiate between add/edit/delete

    - by Josh
    I'm using Virtualmin, and I have a command set up under Virtualmin Module Config Actions Upon Server and user creation Command to run after making changes to a server This command is designed to perform a few additional steps after the account is set up. However, the action is called every time the account is modified, and also gets called when the account is deleted. The actions it performs should only be done when the account is first created. How can my custom command know which action is being performed? Is there an environment variable which determines if the action is creation, alteration, or deletion?

    Read the article

  • Compatibility of ESX 4 and LTO 3 with LSI2032 Dell Power Edge

    - by dbaur
    Hello, does anybody know something about the compatibility of an LTO 3 Tapedrive (PV HH LTO 3 400GB) attached to an LSI2032 SCSI-Controller? These devices are added to an Dell PowerEdge T610 Server which is listed in the certified Compatibility Guide. I can`t find any information for this controller and this tapdevice. Or are they automaticly compatible because they are options for an compatible Server? greetings Dennis

    Read the article

  • Is Splitting IDE hdds between Primary and Secondary faster?

    - by earlz
    Hello, I'm doing RAID 0 on two IDE harddrives (yes, this is old hardware). Will the harddrives be faster if I attach them separately so that one is on the Primary IDE controller and the other is on the Secondary IDE controller? Or would it just be as good as having them both on the Primary IDE as master and slave?

    Read the article

  • Using an SSD with no AHCI [ICH7 base] - Windows 7 hangs frequently

    - by h4xnoodle
    I have a Shuttle Intel G31 + ICH7 (base -- not M/R etc) system. I just bought an OCZ Vertex 3 120gb [VTX3-25SAT3-120G] which includes the Sandforce 2218 firmware. The ICH7 does not support AHCI. I understand that this can be a problem. What I don't understand, is if it's necessary to have the proper performance of this drive. I know that without AHCI I may get a limited read/write speed -- this is fine. What my concern is, is the constant freezing/hangs I'm getting with Windows 7 on any disk activity. The 'Highest Active Time' flip-flops from 0 to 100% every minute or so regardless of large or small files. EDIT: The threads/processes with the highest response time is the kernel. I've been reading about other people with Shuttle SG31G2s, and they seem to be using SSDs no problem. Is this the controller's fault? The fact that I do not have AHCI enabled? It makes sense to me that if this SSD requires AHCI features that it would cause Windows to hang, but I would like to fully determine my situation before returning things/reformatting. To initially have my drive recognise the SSD at all, I had to change the BIOS option to Force Gen II instead of Auto for the SATA controller. I then installed Windows with no problem. There were no errors in the event log related to disk usage, but watching the perfmon I could see the highest active time and the processes (usually pagefile.sys being written to, or chrome/firefox caching) which was correlated to the hanging. So now what I need answered is: should I be returning this SSD and getting one with a different controller, or returning the SSD all-together as it will never work out and I will continue to get these hangs. Posts I've read: Windows 7 New SSD SATA AHCI? -- suggests to use AHCI http://forums.anandtech.com/showthread.php?t=2189868 -- Sandforce issues Windows 7 freezes with SSD -- and attached posts Why does my Windows 7 PC / SSD drive keep freezing? -- this is not the controller I have, but still a related issue. Windows 7 hangs after longer inactivity of user -- also tried messing with power settings with no luck. It was already set to 'Never' for turning off HDDs.

    Read the article

  • 'Memory read error',Sever hardware error?

    - by wss8848
    hello I got a error about my server which is running CentOS5.5. MCE 20 HARDWARE ERROR. This is *NOT* a software problem! Please contact your hardware vendor CPU 1 BANK 8 TSC 6ab9ff9745f62 [at 2394 Mhz 9 days 1:50:52 uptime (unreliable)] MISC cf36ad0100081186 ADDR 203376500 MCG status: MCi status: MCi_MISC register valid MCi_ADDR register valid MCA: MEMORY CONTROLLER RD_CHANNELunspecified_ERR Transaction: Memory read error STATUS 8c0000400001009f MCGSTATUS 0 what is the matter? is memory card error or memory controller error?

    Read the article

  • How can I stop sysprep from interacting with boot on windows 7

    - by Grofit
    I have recently had a laptop sent back to supplier for fixing a mainboard fault. I got it back today and every time it boots up I am faced with: "Setup is preparing windows for first time use" Then once it gets to the desktop I get the sysprep dialog come up asking if I want OOBC or Audit actions. I can close it, but it just keeps coming back, and I cannot find any startup or boot actions, even downloaded autoruns, and that cannot find anything to do with it. Ideally I do not want to format/fdisk as I have just spent hours installing everything on the laptop and I have my primary C:/ which has all windows and at worst case I can get rid of that, but I have a secondary partition D:/ which has alot of stuff I cant lose as its work related and important. Also to make matters more difficult I do not have a windows 7 disk, it was just pre-installed and they dont provide a disk. Any help would be great!

    Read the article

  • Is it possible to boot from a passthrough lsi2008 under esxi?

    - by Kurt
    I currently have Solaris 11 Express running on bare metal. I'd like to convert the machine to an ESXI host and run the existing os as a virtual machine. I have ESXI setup, the virtual machine made, if I boot the vm from the recovery disk the drives and lsi2008 controller is visible. Everything looks like it should work, but the vm bios does not seem to try and boot from the controller. Is this just impossible?

    Read the article

  • How do I set up DNS for an intranet web site?

    - by BradyKelly
    I have a web site running on our local server, 'OBAMA'. In my hosts file on that server, I map engenxt.local to 127.0.0.1, so typing engenxt.local on that machine itself brings up the website. I would like other machines to access the site via domain name 'engenxt'. On a Windows Server 2008 R2 Standard server, where would I begin, where should I go, and where should I end? I know precious little about DNS, or rather precious nothing, but am a quick study, besides, that is why I'm asking how to do this here. Episode 2 When I run DNS as Ryan suggests, it says 'the server OBAMA is unavailable. Do I want to add it?' It adds it, and tells me to choose to 'Configure a DNS server' from the actions menu, but nearly all the actions in that menu are disabled.

    Read the article

  • Are FC and SAS DAS devices standard enough?

    - by user222182
    Before I ask my questions, here is some background info that may or may not be useful: For the first time I find myself needing a DAS solution. My priority is data through-put in a single direction. I can write large blocks, and I don't need to read at the same time. The server (the data producing device) is not really a typical server, its a very powerful single board computer. As such I have limited options when it comes to the add-in cards I can install since it must use the fairly uncommon interface, XMC. Currently I believe I am limited PCIex8 gen 1 which means that the likely bottle neck for me will be this 16gbps connection. XMC Boards I have found so far offer the following connections: a) Dual 10GBE ethernet controller, total throughput 20gbps b) Dual Quad SAS 2.0 Connectors (SFF-8XXX) HBA (no raid), total throughput 48 gbps c) Dual FC 8gb HBA (no raid), total throughput 16gbps My questions for you guys are: 1) Are SAS and/or FC, and by extension their HBAs, standard enough that I could purchase a Dell or Aberdeen storage server with a raid controller that has external SAS or FC ports and expect that I can connect it to my SAS or FC HBA, be presented with a single volume (if I so configured the storage server), all without having to check for HBA compatibility? 2) On a device like a Dell PowerVault (either DAS or NAS) is there an OS on it to concern myself with, or is it meant to be remotely managed? Is there a local interface in case I cant remotely manage it (i.e. if my single board computer uses an OS not supported by Dell OpenManage). Would this be true of nearly any device which calls itself a DAS? 3) If I purchase some sort of Supermicro storage chassis, installed a raid controller with external connections, is there a nice lightweight OS I can run just for management of the controller? Would I even need an OS since the raid card would be configured pre-boot anyway? 4) It is much easier to buy XMC based 10gigabit ethernet cards (generally dual port). In what ways would I be getting into trouble by using iSCSI as a DAS are direct cabling with SFP+ cables? Thanks in advance

    Read the article

  • How to address a recurring low temperature error seen at every boot-up?

    - by GregC
    After updating to latest controller firmware, I started receiving the following error messages: LSI 2208 ROC: Temperature sensor below error threshold on enclosure 1 Sensors 5 thru 7 Is this something I should worry about, or is it a Red Herring? Details: I have a Sans Digital NexentaSTOR 24-disk JBOD enclosure connected to LSI 9286-8e RAID-on-Chip controller with two SAS cables. Seagate ES.2 3TB SAS hard drives populate every bay in the enclosure.

    Read the article

  • How to Edit Domain Password Complexity?

    - by Milad K. Awawdeh
    Hi All, :) My Domain Environment is 2 Domain Controller ( Main & Secondary ) DHCP Mail Server Internet Server & ISA Server 2 DNS Server Primary & Secondary My problem i tried to Remove Password Complexity in my 2 domain Controller but i still receive error message that the password doesn't meet password complexity and i tried to run gpupdate /force after i disabled password complexity and check other condition any one know why I use windows server 2003 Stand alone

    Read the article

  • Program to customize mouse buttons?

    - by roflwaffle
    I have a Logitech M510 wireless mouse and am on a Mac. Right now I can assign different actions to the 2 thumb buttons through the Logitech control panel. What I want to do is have mouse button combos to perform actions. So if I am holding thumb button 1 and click the left button, a tab will close in Chrome. As well as any other "hold one button, click another" combination. Is there any program out there that gives this type of customization?

    Read the article

  • What is the proper position for the loopback address in a DNS server selection list?

    - by Bigbio2002
    Best practices indicate that one should list 127.0.0.1 in the DNS list for the network adapter configuration for a Domain Controller, but not as the first one. With that said, what is the best place to put it in a list with more than two DNS servers listed? Second, last, or it doesn't matter? Also helpful would be an explanation as to why. Related question: What should the order of DNS servers be for the network adapter of a domain controller?

    Read the article

  • Suggestions for splitting server roles amongst Hyper-V virtual servers / RAID6 or RAID10? / AppAssure

    - by Anon
    We have 2 Hyper-V hosts at present running 1 virtual server that was converted from a physical box running all roles. My plan is to split the roles over various virtual machines, upgrading to the latest software versions as I go, and use the backup server as a standby in case the main server fails. AppAssure backup software has a feature called Virtual Standby, so the VHD's can be ready to be fired up on the backup server if necessary. Off-site backups will be done via external USB drive for now. I'm just seeking some input/suggestions into how I'm planning to split the roles out amongst various virtual servers. Also, I'm curious how to setup the storage on the servers. We do not have any NAS's, SAN'S or any budget for this. What would the best RAID level be to use? I'm thinking either RAID6 (which is currently used) however I'm concerned about the write speeds, or RAID10 but again I'm worried that I can only lose 1 drive (from the same mirror) as opposed to any 2 with RAID6. I realise I have a hot swap for this, but what if a further drive fails during a rebuild? Is the write penalty of RAID6 worth the extra reliability over RAID10? Or will it be too slow with all the roles I am planning, therefore RAID10 is my only real option? The reason for the needed redundancy is I am the only technician and I'm not always on-site. Options I've considered: 1) 5 drives in RAID6 set, 200gb for host OS, rest for VM storage. 1 drive for hot swap - this is how it is currently setup 2) 4 drives in RAID10 set, 200gb for host OS, rest for VM storage. 2 drives for hot swap 3) 4 drives in RAID10 set for VM storage, 2 drives in RAID1 set for host OS. No drives for hot swap - While this is probably the best option with the amount of drives I have, I don't like the idea of having no hot swap 4) 3 drives in RAID6 set for VM storage, 2 drives in RAID1 set for host OS. 1 drive for hot swap All options give us enough storage capacity for our files, etc. We don't have any budget for extra drives or extra hot swap HD chassis for the servers. We have about 70 clients and about 150 users. MAIN SERVER Intel Xeon 5520 @ 2.27 GHz (2 processors) 16GB RAM 6 x 1TB Seagate Barracuda ES.2 Enterprise SATA drives Intel SRCSATAWB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: DC01 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM DC02 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM Member Server - DHCP server, File server, Print server - 1GB RAM SCCM Member Server - 4GB RAM Third Party Software Member Server - A/V server, Ticketing software, etc - 4GB RAM Exchange 2007 - 4GB RAM - however we are probably migrating to a hosted solution, therefore freeing up resources BACKUP SERVER Intel Xeon E5410 @ 2.33GHz (2 processors) 16GB RAM 6 x 2TB WD RE4 SATA drives Intel SRCSASRB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: AppAssure backup software - 8GB RAM

    Read the article

  • Symfony sfControlPanel 500 error only when executing 'tasks'

    - by rrlange
    As a bit of background, I recently had to restore a Symfony site from backup. Ever since the 'successful' restore, I am running into an exception when trying to execute a(ny) task via the web-based sfControlPanel: Unable to find PHP executable stack trace * at sfToolkit::getPhpCli() in SF_ROOT_DIR/plugins/sfControlPanelPlugin/modules/sfControlPanel/actions/actions.class.php line 93 FYI: symfony version 1.0.6 PHP 5.2.6 (cli) (built: May 2 2008 16:06:40) Apache/2.2.3 CentOS 5.* Thank you very much for any and all suggestions as to what might be amiss. Addendum: I neglected to mention that I can the frontend app (and certain backend apps) perfectly fine via the web. I am also able to run common tasks via the command line (cc etc.).

    Read the article

  • In-Place DC Upgrade from Server 2003R2 Standard to 2008 Enterprise

    - by Yadhu Tony
    We have a Domain controller in server 2008 Enterprise and Additional DC in server 2003 R2. Now I need to upgrade Additional Domain controller to Server 2008 Enterprise and raise the domain functional level to 2008. The DC is running with Active Directory, DNS and DHCP. The server is installed in VMware ESXi 4.0. Please guide me to carry out the upgrade. Also I want to know about the possible risk of in-place upgrade, if any.

    Read the article

  • If Nvidia Shield can stream a game via wifi, why can I not do the same via ethernet to any other PC?

    - by Enigma
    I think it absurd that a wireless game streaming solution is the *first to hit the market when a 1000mbps+ Ethernet connection would accomplish the same feat with roughly 6x the available bandwidth. I can only assume that there must be some reason behind this or a limitation preventing this, but what? 150mbps wifi is in no way superior to a 1000mbps LAN connection aside from well wireless mobility. Not only that but I have a secondary laptop and desktop which should by hardware comparison completely outperform anything the Tegra in the Nvidia Shield can do. Is this all just a marketing scheme to force people to buy the shield for the streaming benefit? Chief among these is that NVIDIA’s Shield handheld game console will be getting a microconsole-like mode, dubbed “Shield Console Mode”, that will allow the handheld to be converted into a more traditional TV-connected console. In console mode Shield can be controlled with a Bluetooth controller, and in accordance with the higher resolution of TVs will accept 1080p game streaming from a suitably equipped PC, versus 720p in handheld mode. With that said 1080p streaming will require additional bandwidth, and while 720p can be done over WiFi NVIDIA will be requiring a hardline GigE connection for 1080p streaming (note that Shield doesn’t have Ethernet, so this is presumably being done over USB). Streaming aside, in console mode Shield will also support its traditional local gaming/application functionality. - http://www.anandtech.com/show/7435/nvidia-consolidates-game-streaming-tech-under-gamestream-brand-announces-shield-console-mode ^ This is not acceptable for me for a number of reasons not to mention the ridiculousness of having a little screen+controller unit sitting there while using a secondary controller and screen instead. That kind of redundant absurdity exemplifies how wrong of a solution that is. They need a second product for this solution without the screen or controller for it to make sense... at which point your just buying a little computer that does what most other larger computers do better. All that is required, by my understanding, is the ability to decode H.264 video compression and transmit control/feedback so by any logical comparison, one (Nvidia especially) should have no difficulty in creating an application for PC's (win32/64 environment) that does the exact same thing their android app does. I have 2 video cards capable of streaming (encoding) H.264 so by right they must be capable of decoding it I would think. I haven't found anything stating plans to allow non-shield owners to do this. Can a third party create this software or does it hinge on some limitation that only Nvidia can overcome? (*) - perhaps this isn't the first but afaik it is the first complete package.

    Read the article

  • Django | Apache | Deploy website behind SSL

    - by planet260
    So here are my requirements. I have a website built in Django. I deployed it on Apache Ubuntu. Before there was no SSL involved so the deployment was pretty simple. But now the requirements are changed. Now I have to take a few actions like signup and login behind SSL and present the admin panel and other normally via HTTP. By following the this tutorial I have set-up Apache and SSL and generated certificates for SSL communication. But I am not sure how to proceed, ie. how to serve only a few of my actions through SSL. Below is my configuration. The normal actions are working fine but I don't know how to configure SSL calls. WSGIScriptAlias / /home/ubuntu/myproject/src/myproject/wsgi.py WSGIPythonPath /home/ubuntu/myproject/src <VirtualHost *:80> ServerName mydomain.com <Directory /home/ubuntu/myproject/src/myproject> <Files wsgi.py> order deny,allow Allow from all </Files> </Directory> Alias /static/admin/ "/home/ubuntu/myproject/src/static/admin/" <Directory "/home/ubuntu/myproject/src/static/admin/"> Order allow,deny Options Indexes Allow from all IndexOptions FancyIndexing </Directory> <Location "/login"> RewriteEngine on RewriteRule /admin(.*)$ https://mydomain.com/login$1 [L,R=301] </Location> </VirtualHost> <VirtualHost *:443> ServerName mydomain.com SSLEngine on SSLOptions +StrictRequire SSLCertificateFile /etc/apache2/ssl/apache.crt SSLCertificateKeyFile /etc/apache2/ssl/apache.key <Directory /home/ubuntu/myproject/src/myproject> <Files wsgi.py> order deny,allow Allow from all </Files> </Directory> Alias /static/admin/ "/home/ubuntu/myproject/src/static/admin/" <Directory "/home/ubuntu/myproject/src/static/admin/"> Order allow,deny Options Indexes Allow from all IndexOptions FancyIndexing </Directory> </VirtualHost> Can you please help me out on how to achieve this? What am I doing wrong? I have read a lot of tutorials but honestly I am not really good at configurations. Any help is appreciated.

    Read the article

  • HP Proliant G7 hardware RAID configuration automation with ribcl

    - by karthik
    I have been trying to automate hardware RAID configuration of HP proliant machines before OS installation (So I can not use hpacucli) ssh into iLO3 doesn't have option for RAID configuration I use ribcl but there is no command for RAID config, however I see this under the command GET_EMBEDDED_HEALTH. <STORAGE> <CONTROLLER> <LABEL VALUE="Controller on System Board"/> <STATUS VALUE="OK"/> <CONTROLLER_STATUS VALUE="OK"/> <SERIAL_NUMBER VALUE="50014380215F0070"/> <MODEL VALUE="HP Smart Array P420i Controller"/> <FW_VERSION VALUE="3.41"/> <DRIVE_ENCLOSURE> <LABEL VALUE="Port 1I Box 1"/> <STATUS VALUE="OK"/> <DRIVE_BAY VALUE="04"/> </DRIVE_ENCLOSURE> <DRIVE_ENCLOSURE> <LABEL VALUE="Port 2I Box 0"/> <STATUS VALUE="OK"/> <DRIVE_BAY VALUE="01"/> </DRIVE_ENCLOSURE> <LOGICAL_DRIVE> <LABEL VALUE="01"/> <STATUS VALUE="OK"/> <CAPACITY VALUE="68 GB"/> <FAULT_TOLERANCE VALUE="RAID 0"/> <PHYSICAL_DRIVE> <LABEL VALUE="Port 1I Box 1 Bay 3"/> <STATUS VALUE="OK"/> <SERIAL_NUMBER VALUE="6TA0N3SZ0000B231CYDT"/> <MODEL VALUE="EH0072FAWJA"/> <CAPACITY VALUE="68 GB"/> <LOCATION VALUE="Port 1I Box 1 Bay 3"/> <FW_VERSION VALUE="HPDH"/> <DRIVE_CONFIGURATION VALUE="Configured"/> </PHYSICAL_DRIVE> </LOGICAL_DRIVE> </CONTROLLER> </STORAGE> My question is, is there a way I modify/create this xml piece (say I have 2 Logical drive with one spare) and reboot the server it takes effect ? If this approach is not correct are there any other ways to automate hardware raid config ?

    Read the article

  • Can I see if and when a file was deleted on Windows Server 2003?

    - by user316687
    On Windows Server 2003, is there a way to see if and when a file was deleted? It's a web server with IIS, our web application let our users to load Word documents into server. However, we found that one Word file is missing, and would like to know is it was deleted or never existed (web app could'nt load it). EDIT: I tried to follow this: Enable auditing the folder you want to keep track of. Just right click on the folder, go to “sharing and security”, then “security” tab, at the bottom click on “advanced”. Select the auditing tab, click add, select the group or users to track, then pick what actions you want to track. To track file deletion you would enable: Create files/Write data Success/Fail Create folders / append data Success/Fail Delete Subfolders/Files Success/Fail Delete Suceess/Fail This one will apply from now on, past actions wouldn't be able to track?

    Read the article

  • Is it possible to use Linux as a Fibre Channel Raid Disk Box?

    - by SvenW
    You probably all know the relatively simple RAID boxes exporting a bunch of SATA disks as one big drive via FC, SAS or iSCSI, like the HP StorageWorks MSA2000, Infortrends EonStore series or many different other models from different manufacturers. Is it possible to create such a device with Linux, a few disks and an FC controller, using the controller in the reverse direction than usual? This would come handy to test some ideas and concepts in an emerging SAN environment.

    Read the article

  • Windows 7 immediately disconnects a USB drive

    - by Daniel Saner
    I am having a problem with Windows 7 x64 consistently disconnecting one specific USB mass storage drive immediately after it is connected. The drive in question is a Cowon C2 digital music player which works in standard mass storage controller mode (i.e. no device-specific drivers needed/available). When I connect the player, Windows plays the "USB connect" sound and the device appears (under its correct name) in the device manager, but it never appears as a drive. The player itself displays "USB Connected" for a split-second before reporting that it has been disconnected again. Since the player, by design, reboots after it has been disconnected, Windows plays the "USB disconnect" sound before restarting the whole cycle once the player has powered back on. I am connecting the player through an Intel X79 Chipset motherboard (Gigabyte GA-X79-UD3) to Windows 7 Pro 64-bit. The player used to work fine the first few times I connected it, showing up as an external drive; it only recently stopped working. It is not a problem with the player, since it works fine when connected to another computer, even such running the exact same operating system. It is also not a problem with the USB controller, since the issue is the same on both the Intel USB 2.0 and the Fresco Logic FL1009 USB 3.0 controller ports. I have also not had the problem with any other drive so far. Among the things I have tried so far: Disabling USB legacy mode in BIOS Disabling energy-saving power down for all USB controllers in Windows' device manager Removing and reinstalling Windows' USB mass storage driver Removing and reinstalling Intel and Fresco Logic USB controller driver Restoring the player to factory defaults None of these made a difference. Again, the player used to work fine on the exact same system just days ago; I didn't install any new hardware or drivers on it since then. I would be very grateful for any hints on what else to try. Edit: Here is another new hint; I found out that when I connect the drive before booting Windows, it is available in Windows Explorer as it should, and does not automatically disconnect. If I remove and reconnect it though, the infinite connect/disconnect-loop starts anew.

    Read the article

  • How does plugging in a SATA drive to an SAS backplane affect maximum cable length?

    - by user179658
    The limit on SATA cable length is 1m, whereas the limit on SAS cable length is 10m. When using a backplane which advertises support for SAS and SATA, with a SAS RAID controller and one SATA drive, will the controller use the SAS PHY scheme, allowing for the 10m cable length maximum (to accommodate the long backplane), or will it use the SATA one and allow for only the SATA cable length maximum of 1m?

    Read the article

< Previous Page | 120 121 122 123 124 125 126 127 128 129 130 131  | Next Page >