Search Results

Search found 13467 results on 539 pages for 'port mapping'.

Page 126/539 | < Previous Page | 122 123 124 125 126 127 128 129 130 131 132 133  | Next Page >

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • Trying to use a SmartHost with my Exchange 2010 server

    - by Pure.Krome
    Hi folks, I'm trying to use a SmartHost with my Exchange 2010 Server. SmartHost details: Secure SMTPS: securemail.internode.on.net 465 <-- Note: that's port 465 Configure your existing SMTP settings (in your email program) to: use authentication (enter your Internode username and password, enter your username as [email protected]). enable SSL for sending email (SMTPS). So I've added the smart host details to my Org Config -> Hub Transport. I then used PowerShell to add the port:- Set-SendConnector "securemail.internode.on.net" -port 465 I've then added my username/password (as suggested above) to the SmartHost as Basic Authentication (with no TLS). Then I try sending an email and I get the following error message :- 451 4.4.0 Primary target IP address responded with: "421 4.4.2 Connection dropped due to ConnectionReset." So i'm not sure how to continue. I also tried ticking the TLS box but stll I get the same error. If i don't use SMTPS (secure SMTP, on port 465) and use basic SMTP on port 25 with no Authentication, email gets sent. Any ideas? EDIT: Btw, I can telnet to that server on port 465 from my mail server .. just to make sure i'm not getting firewall'd, etc.

    Read the article

  • How to get gigabit network speeds on Windows XP?

    - by JB
    We've just installed gigabit switches at work, and things on the Linux side are going well. Our linux boxes, which use a Intel Corporation 82566DM-2 Gigabit nic (according to lspci), consistently get over 900 mbits/sec: iperf -c ipserver ------------------------------------------------------------ Client connecting to ipserver, TCP port 5001 TCP window size: 16.0 KByte (default) ------------------------------------------------------------ [ 3] local 192.168.40.9 port 39823 connected with 192.168.1.115 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 1.08 GBytes 929 Mbits/sec We have a bunch of Windows XP 64-bit machines that use Broadcom NetXtreme 57xx cards. I spent around a day trying to get equivalent speeds on them, but couldn't get above 200 Mbits/sec. I noticed the Windows iperf tests said that the TCP window size was 8 Kb by default (as opposed to 16 Kb on Linux, so I modified my test to reflect that. Still no love. I went to Broadcom's site, downloaded the latest drivers for the card and installed. Still no love. However, finally, I tried a 64 Kb window size with the new drivers, and finally an improvement! $ iperf -c ipserver -w64k ------------------------------------------------------------ Client connecting to ipserver, TCP port 5001 TCP window size: 64.0 KByte ------------------------------------------------------------ [ 3] local 192.168.40.214 port 1848 connected with 192.168.1.115 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 933 MBytes 782 Mbits/sec Much better, but still not really taking advantage of the full capabilities of the network. If the Linux box can reach 950 Mbits/sec consistently, this box should be able to as well. Also, if you're wondering about the medium, this is over the same cable...I'm switching back and forth. Any suggestion or ideas would be really welcome. Thanks!

    Read the article

  • OpenBSD logins via SSH seem to be ignoring my configured radius server

    - by Steve Kemp
    I've installed and configured a radius server upon my localhost - it is delegating auth to a remote LDAP server. Initially things look good: I can test via the console: # export user=skemp # export pass=xxx # radtest $user $pass localhost 1812 $secret Sending Access-Request of id 185 to 127.0.0.1 port 1812 User-Name = "skemp" User-Password = "xxx" NAS-IP-Address = 192.168.1.168 NAS-Port = 1812 rad_recv: Access-Accept packet from host 127.0.0.1 port 1812, id=185, Similarly I can use the login tool to do the same thing: bash-4.0# /usr/libexec/auth/login_radius -d -s login $user radius Password: $pass authorize However remote logins via SSH are failing, and so are invokations of "login" started by root. Looking at /var/log/radiusd.log I see no actual log of success/failure which I do see when using either of the previous tools. Instead sshd is just logging: sshd[23938]: Failed publickey for skemp from 192.168.1.9 sshd[23938]: Failed keyboard-interactive for skemp from 192.168.1.9 port 36259 ssh2 sshd[23938]: Failed password for skemp from 192.168.1.9 port 36259 ssh2 In /etc/login.conf I have this: # Default allowed authentication styles auth-defaults:auth=radius: ... radius:\ :auth=radius:\ :radius-server=localhost:\ :radius-port=1812:\ :radius-timeout=1:\ :radius-retries=5:

    Read the article

  • Using IIS7 as a reverse proxy

    - by Eric Petroelje
    I'm setting up a server at home to host a few small websites. One of them is .NET based and needs IIS, the others are PHP based and need Apache. So, I have both IIS 7 and Apache 2.2.x installed on my server with IIS on port 80 and Apache running on port 8080. I would like to set up IIS to work as a reverse proxy, forwarding the requests for the Apache sites to port 8080 and serving the requests for the .NET site itself based on the host headers. Like this: www.mydotnetsite.com/* -> IIS -> serve from IIS www.myapachesite.com/* -> IIS -> forward to apache on port 8080 www.myothersite.com/* -> IIS -> forward to apache on port 8080 I did a bit of googling and it seemed like the Application Request Routing feature would do what I needed, but I can't seem to get it to work the way I want it to. I can get it to forward ALL traffic to the Apache server and I can get it to forward traffic with a specific URL pattern to the Apache server, but I can't seem to get it to forward based on the host headers (e.g. "forward all requests for www.apachesite.com - localhost:8080") So the question is, how would I go about configuring ARR to do this? Or do I need a different tool? I'm also open to using Apache as the reverse proxy and forwarding the .NET site requests to IIS instead if that's easier (running Apache on port 80 and IIS on 8080).

    Read the article

  • Xen PV packet loss

    - by Delphinator
    I'm having some serious issues with packetloss with one of my servers. This server is a somewhat old (P4-era) machine running Debian Squeeze and Xen 4.0. There are two domUs running on it (both also Debian Squeeze), one gateway and a fileserver. Unfortunatly the processor has no virtualization extensions, therefore only PV can be used. While investigating why our network seems to be slower than it should I found some pretty bad packet loss (~25%). After further investigation and several experiments I did a measurment between the dom0 and one of the domUs: Server listening on UDP port 5001 Receiving 1470 byte datagrams UDP buffer size: 110 KByte (default) ------------------------------------------------------------ ------------------------------------------------------------ Client connecting to dom0, UDP port 5001 Sending 1470 byte datagrams UDP buffer size: 110 KByte (default) ------------------------------------------------------------ [ 3] local 192.168.1.2(domU) port 33817 connected with 192.168.1.100(dom0) port 5001 [ 4] local 192.168.1.2(domU) port 5001 connected with 192.168.1.100(dom0) port 48606 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 46.3 MBytes 38.7 Mbits/sec [ 3] Sent 33020 datagrams [ 3] Server Report: [ 3] 0.0-10.0 sec 46.2 MBytes 38.6 Mbits/sec 0.030 ms 89/33019 (0.27%) [ 3] 0.0-10.0 sec 1 datagrams received out-of-order [ 4] 0.0-10.2 sec 43.0 MBytes 35.3 Mbits/sec 13.074 ms 11575/42256 (27%) tl;dr: 27% packet loss from dom0 to domU with 50Mbit UDP packets. Same thing happens from anywhere in the network. The problem gets better for smaller bandwidths (0.047% for 5Mbit) and worse for higher (59% for 200Mbit) ones. I did increase the CPU-weight of the dom0, there is no swapping going on, and actual networking-hardware is not involved. I never expected Xen (or anything related) to drop packets, and I'm completly clueless what to try next.

    Read the article

  • Adding third disk as a single disk in a server with an existing RAID1

    - by slowhandsolo
    I've got a ProLiant DL360 G5 server (Fedora 13) with two SAS disks in a hardware RAID 1, working fine. Now I hot plugged another SAS disk. I'd like to configure this new hard disk out of my RAID, as a single non-RAID disk (ex. /dev/sdb). Even after rebooting the server, I can't see the new disk with "fdisk -l". It displays only my hardware RAID, but not the new disk. [root@myserver]# fdisk -l Disco /dev/cciss/c0d0: 300.0 GB, 299966445568 bytes Disposit. Inicio Comienzo Fin Bloques Id Sistema /dev/cciss/c0d0p1 * 1 126 512000 83 Linux /dev/cciss/c0d0p2 126 71798 292422656 8e Linux LVM Disco /dev/dm-0: 234.9 GB, 234881024000 bytes Disco /dev/dm-1: 10.5 GB, 10536091648 bytes Disco /dev/dm-2: 21.0 GB, 20971520000 bytes Disco /dev/dm-3: 31.5 GB, 31474057216 bytes Disco /dev/dm-4: 1577 MB, 1577058304 bytes However, I can see the new disk using the HP Array Configuration Utility CLI for Linux "hpacucli": [root@myserver]# hpacucli => controller slot=0 physicaldrive all show status physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 300 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 300 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 300 GB): OK => controller slot=0 pd all show detail Smart Array P400i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 **unassigned** physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: **Unassigned Drive** As you can see, I've got two SAS disks in a RAID 1 and the new disk as "unassigned". Is there any way to work with the new disk as another non-RAID single disk? If relevant, I want to create a new partition in my new disk, format it with mkfs and mount it, but as I can't see it with fdisk, I don't know how to do it. Thanks!

    Read the article

  • iptables forwarding to a dummy interface

    - by madinc
    Hi, I'm trying to accomplish the following: I have a box with a service listening on a dummy interface (say 172.16.0.1), udp port 5555. Now what I'd like to do is to take packets that arrive on interfaces eth0 (1.1.1.1:5555) and eth1 (2.2.2.2:5555) and forward them to the service on the dummy interface, and have replies go back to clients out the same physical interface they came in. Clients must think they're talking to 1.1.1.1:5555 or 2.2.2.2:5555. I think I need a mix of iptables rules and packet marking, plus some iproute rules (if it's possible at all). What I tried is to catch packets coming in from eth0 and eth1, udp port 5555, and mark them with 1 and 2 respectively, and --save-mark in the connmark. Then I used a DNAT to 172.16.0.1. The service seems to be getting the packets. Now I'm not sure how to do the reverse. It seems that for packets originating from the box, you can't do anything before the routing decision, but that would be the place to restore the marks, and thus make a routing decision based on those. Here's what I have so far: iptables -t mangle -A PREROUTING -d 1.1.1.1 -p udp --port 5555 -j MARK --set-mark 1 iptables -t mangle -A PREROUTING -d 2.2.2.2 -p udp --port 5555 -j MARK --set-mark 2 iptables -t mangle -A PREROUTING -d 1.1.1.1 -p udp --port 5555 -j CONNMARK --save-mark iptables -t mangle -A PREROUTING -d 2.2.2.2 -p udp --port 5555 -j CONNMARK --save-mark iptables -t nat -A PREROUTING -m mark --mark 1 -j DNAT --to-destination 172.16.0.1 iptables -t nat -A PREROUTING -m mark --mark 2 -j DNAT --to-destination 172.16.0.1 # What next? As I said, I'm not even sure it can be done. To give a bit of background, it's an old OpenVPN installation that cannot be upgraded (otherwise I'd install a recent version that supports multihoming natively). Thanks for any help.

    Read the article

  • iperf max udp multicast performance peaking at 10Mbit/s?

    - by Tom Frey
    I'm trying to test UDP multicast throughput via iperf but it seems like it's not sending more than 10Mbit/s from my dev machine: C:\> iperf -c 224.0.166.111 -u -T 1 -t 100 -i 1 -b 1000000000 ------------------------------------------------------------ Client connecting to 224.0.166.111, UDP port 5001 Sending 1470 byte datagrams Setting multicast TTL to 1 UDP buffer size: 8.00 KByte (default) ------------------------------------------------------------ [156] local 192.168.1.99 port 49693 connected with 224.0.166.111 port 5001 [ ID] Interval Transfer Bandwidth [156] 0.0- 1.0 sec 1.22 MBytes 10.2 Mbits/sec [156] 1.0- 2.0 sec 1.14 MBytes 9.57 Mbits/sec [156] 2.0- 3.0 sec 1.14 MBytes 9.55 Mbits/sec [156] 3.0- 4.0 sec 1.14 MBytes 9.56 Mbits/sec [156] 4.0- 5.0 sec 1.14 MBytes 9.56 Mbits/sec [156] 5.0- 6.0 sec 1.15 MBytes 9.62 Mbits/sec [156] 6.0- 7.0 sec 1.14 MBytes 9.53 Mbits/sec When I run it on another server, I'm getting ~80Mbit/s which is quite a bit better but still not anywhere near the 1Gbps limits that I should be getting? C:\> iperf -c 224.0.166.111 -u -T 1 -t 100 -i 1 -b 1000000000 ------------------------------------------------------------ Client connecting to 224.0.166.111, UDP port 5001 Sending 1470 byte datagrams Setting multicast TTL to 1 UDP buffer size: 8.00 KByte (default) ------------------------------------------------------------ [180] local 10.0.101.102 port 51559 connected with 224.0.166.111 port 5001 [ ID] Interval Transfer Bandwidth [180] 0.0- 1.0 sec 8.60 MBytes 72.1 Mbits/sec [180] 1.0- 2.0 sec 8.73 MBytes 73.2 Mbits/sec [180] 2.0- 3.0 sec 8.76 MBytes 73.5 Mbits/sec [180] 3.0- 4.0 sec 9.58 MBytes 80.3 Mbits/sec [180] 4.0- 5.0 sec 9.95 MBytes 83.4 Mbits/sec [180] 5.0- 6.0 sec 10.5 MBytes 87.9 Mbits/sec [180] 6.0- 7.0 sec 10.9 MBytes 91.1 Mbits/sec [180] 7.0- 8.0 sec 11.2 MBytes 94.0 Mbits/sec Anybody has any idea why this is not achieving close to link limits (1Gbps)? Thanks, Tom

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • Are my iptables secure?

    - by Patricia
    I have this in my rc.local on my new Ubuntu server: iptables -F iptables -A INPUT -i eth0 -p tcp --sport 22 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 22 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --dport 22 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --sport 22 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 9418 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --sport 9418 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 5000 -m state --state NEW,ESTABLISHED -j ACCEPT # Heroku iptables -A INPUT -i eth0 -p tcp --sport 5000 -m state --state ESTABLISHED -j ACCEPT # Heroku iptables -A INPUT -p udp -s 74.207.242.5/32 --source-port 53 -d 0/0 --destination-port 1024:65535 -j ACCEPT iptables -A INPUT -p udp -s 74.207.241.5/32 --source-port 53 -d 0/0 --destination-port 1024:65535 -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 443 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --sport 443 -m state --state ESTABLISHED -j ACCEPT iptables -P INPUT DROP iptables -P FORWARD DROP 9418 is Git's port. 5000 is a port used to manage Heroku apps. And 74.207.242.5 and 74.207.241.5 are our DNS servers. Do you think that this is secure? Can you see any holes here? Update: Why is it important to block OUTPUT? This machine will be used only by me.

    Read the article

  • How to connect 2 routers (Asmax and D-link)

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • Not getting IP from ISP on Multicast Network

    - by Johan Nielsen
    Im having an odd issue with my ISP (COMX.dk) I have a managed access gateway box (Telsay) with three 8P8C ports for use with Internet and Ip-Tv (respectively on different VLANS (so does my ISP tell me)) To utilize a port you will need to register your device's mac address through an online interface. You will then get your device paired with a static ip. I am using one port actively and I have registered another device (router). The router is configured to listen for an active dhcpd on the network. When my router get a lease I get a private ip 192.168.2.2 (not the one bound to my mac) which is odd! I unconnected my router from the gateway and connected my laptop directly. Same thing happened - I was given a private address. I did a port scan on the gateway and found port 80 to be open and browsed to the ip. I was then presented with a management interface of a Belkin wireless router (HMMM!!!!) <--by the way, not my gear At this point I called the ISP to let them know of my issue/findings - Only to be replied "Well, we cant see any rogue dhcp servers" (thinking to myself, well I can) I then decided that it could be fun to try the other port of my gateway, only to experience the same. So I reconnected my router and used the remaining port to make an observer(wireshark promic etc.) I am able to see my router trying to discover a dhcp server but I can also see my ISP's IGMP and PIMv2 packages just repeating the same pattern. Hello...Hello...Hello :) So I called them again, only to get the same response, "we dont see any rogue dhcp's...we cant see the host you are talking to (mac address of the Belkin router)...you are definitively connected through wireless?!?(no im not, no such thing as a wireless wire - i thought to myself)" My questions is, What is going on? (besides from what im reporting here) What am I seeing that the don't? What can I tell them in order for them to resolve mine/their issue?

    Read the article

  • HP dv6910 laptop no longer recognizes wireless adapter, dvd drive, and one usb port. What can I do about this?

    - by Joan H.
    In the last 3 weeks, my not even 3 year old HP laptop (vista) just seems to be failing. First, one of the usb ports stopped working. Next, the dvd drive all of a sudden was not recognized as even existing, so it is now useless. And as of today, I no longer seem to have a wireless adapter on my laptop. It doesn't show up in device manager, same as the dvd drive. I can connect to the internet by ethernet cable, but not wirelessly. It worked fine last night; now it doesn't even exist! I have tried a 'hard reset' I read about on HP's forum- no help. I am not sure what else to try. I read about the USB wifi dongle in another response, but I already have maxed our my usb ports even though I have bought a USB hub since the one port failed. Plus, I'd like my laptop to just work like it's supposed to instead of being jerry rigged with usb hubs, external dvd drives, and wifi dongles etc. Any ideas?

    Read the article

  • How to play WAV file through Network Paging Interface

    - by BGM
    In our building we have a Viking Paging ZPI-4 Interface for our intercom. The interface receives data from our Asterisk Phone system via a Cisco SPA112 Port Adapter which has it's own IP address on the network and converts digital into analog. Asterisk plays the "5" tone and then allows the user's voice to commence over the connection. Now, what I want to do is to play a wav file over this Viking Paging device using the Cisco Port Adapter. I know how to get Asterisk to do it, but I want to do this without Asterisk. I want some kind of program that can talk to the Cisco Port Adapter and then transmit the wav file into the Viking Paging Device. What kind of program do I need to get or make? Now, I found this link if it helps anyone with ideas. I also found this information, but I'm not sure how to apply it. I also found this, but it involves an arduino. However, I already have the analog-to-digital convertor, and the Viking will handle sending sound over the paging speakers. I just need to know how to send the wav file to the Viking via the Port Adapter. So far, I know my wav file should be formatted as 8bit mono, and I need to send the "5" tone to open the Viking Pager's channel. [update] I am trying to figure out if I can use VLC player to stream to the ipaddress of the Port Adapter. So far I'm not having success with that, and don't even know if it will work. Windows Media Player has a streaming option too. I am thinking that since the Cisco Port Adapter thinks it is a sort of phone, that the only way this can be done is via SIP.

    Read the article

  • Simple vLAN setup

    - by Logan Bissonnette
    I have a basic lab environment set up to try and get 2 vLANs working in hyper-v. I have the following equipment 1 hyper-v server 1 Desktop PC 1 Managed Switch (d-link DES-3052P) 1 cheap router (DI-604) My end goal is to have 1 VM and the desktop on one vLAN with internet, and 1 VM on a separate vLAN with internet access. I am having troubles getting an internet connection to both vLANs. The switch does not have the ability to have asynchronous vLANs. This is my switch configuration Port 1 - Trunk Port - Connected to router Port 2 - Trunk Port - Connected to hyper-v Server Port 3 - Access Port- Connected to Desktop Within hyper-v I have 1 switch and 2 VMs. When the VMs are set up to use vlan ID 1, everything works fine. As soon as a VM is set up to use vlan ID 2, they lose all network connection and cannot communicate with the router anymore. I believe this is because the router is not vLAN aware. Can anyone help me with what settings need to be set up on my switch? I believe I want an egress rule so traffic leaving towards the router is untagged, is that right? If not, any ideas or hints as to what needs to be set up?

    Read the article

  • esx5 debian VM vlan setup

    - by Kstro21
    i have a server with ESX5, have a switch with about 20 vlans, this is how setup the trunk port interface GigabitEthernet0/1/1 description ToOper port link-type trunk undo port trunk allow-pass vlan 1 port trunk allow-pass vlan 2 to 14 stp disable ntdp enable ndp enable bpdu enable then, i created a standar switch(sw1) using the vSphere Client, the VLAN ID is set to All (4095), i also created a VM with Debian 6, with a NIC connected to sw1, now, i want to configure this NIC for a selected group of vlans auto vlan10 iface vlan10 inet static address 11.10.1.0 netmask 255.255.255.224 mtu 1500 vlan_raw_device eth0 auto vlan14 iface vlan14 inet static address 11.10.1.65 netmask 255.255.255.248 mtu 1500 vlan_raw_device eth0 so, when i restart the network using /etc/init.d/networking restart, i got this error Reconfiguring network interfaces...SIOCSIFADDR: No such device vlan14: ERROR while getting interface flags: No such device SIOCSIFNETMASK: No such device SIOCSIFBRDADDR: No such device vlan14: ERROR while getting interface flags: No such device SIOCSIFMTU: No such device vlan14: ERROR while getting interface flags: No such device Failed to bring up vlan14. done. this is just part of the error, so, my questions is: is this possible?, i mean, what i'm trying to achieve using ESX Virtual Machines, VLANS, etc is this a Debian problem? can be solved? i've read about a file named z25_persistent-net.rules in Debian but it doesn't exist in my installation. in the In the vSphere Networking for ESX5 guide, you can read: If you enter 0 or leave the option blank, the port group can see only untagged (non-VLAN) traffic. If you enter 4095, the port group can see traffic on any VLAN while leaving the VLAN tags intact. So, in theory, it should work, right? Hope you can help me up with this one Thanks

    Read the article

  • use ssh tunnel with phpmyadmin

    - by JohnMerlino
    I been using ssh tunnel to bypass firewall of remote mysql server. On my Ubuntu 12.04 installation, it works via the terminal and it works when using a program called mysql workbench. However, that program freezes often and I want to try phpmyadmin as an alternative. However, I cannot connect to remote server using ssh tunnel on phpmyadmin, albeit I can connect locally. These are the steps I've tried: 1) Open a tunnel, listening on localhost:3307 and forwarding everything to xxx.xxx.xxx.xxx:3306 (used 3307 because MySQL on my local machine uses the default port 3306): ssh -L 3307:localhost:3306 [email protected] So now I have the port for tunnel open and I have my local mysql installation default port: $ netstat -tln Active Internet connections (only servers) Proto Recv-Q Send-Q Local Address Foreign Address State tcp 0 0 127.0.0.1:3306 0.0.0.0:* LISTEN tcp 0 0 127.0.0.1:3307 0.0.0.0:* LISTEN tcp 0 0 0.0.0.0:80 0.0.0.0:* LISTEN ... 2) Now I can easily connect to remote server via localhost using the terminal: $ mysql -u user.name -p -h 127.0.0.1 -P 3307 Notice that I expicitly identify 3307 as the port, so traffic forwards to the remote server, and hence it logs me in to the remote server. Unfortunately, the localhost/phpmyadmin local login interface doesn't allow you to specify a port option. So I modify the config-db.php file and change the $dbport variable to 3307, under the impression that the phpmyadmin interface will now work with port 3307: $ sudo vim /etc/phpmyadmin/config-db.php $dbport='3307'; Then I restart the mysql server. Unfortunately, it didn't work. When I use the remote credentials to login, it gives me error: #1045 Cannot log in to the MySQL server

    Read the article

  • NHibernate and Stored Procedures in C#

    - by Jess Nickson
    I was recently trying and failing to set up NHibernate (v1.2) in an ASP.NET project. The aim was to execute a stored procedure and return the results, but it took several iterations for me to end up with a working solution. In this post I am simply trying to put the required code in one place, in the hope that the snippets may be useful in guiding someone else through the same process. As it is kind’ve the first time I have had to play with NHibernate, there is a good chance that this solution is sub-optimal and, as such, I am open to suggestions on how it could be improved! There are four code snippets that I required: The stored procedure that I wanted to execute The C# class representation of the results of the procedure The XML mapping file that allows NHibernate to map from C# to the procedure and back again The C# code used to run the stored procedure The Stored Procedure The procedure was designed to take a UserId and, from this, go and grab some profile data for that user. Simple, right? We just need to do a join first, because the user’s site ID (the one we have access to) is not the same as the user’s forum ID. CREATE PROCEDURE [dbo].[GetForumProfileDetails] ( @userId INT ) AS BEGIN SELECT Users.UserID, forumUsers.Twitter, forumUsers.Facebook, forumUsers.GooglePlus, forumUsers.LinkedIn, forumUsers.PublicEmailAddress FROM Users INNER JOIN Forum_Users forumUsers ON forumUsers.UserSiteID = Users.UserID WHERE Users.UserID = @userId END I’d like to make a shout out to Format SQL for its help with, well, formatting the above SQL!   The C# Class This is just the class representation of the results we expect to get from the stored procedure. NHibernate requires a virtual property for each column of data, and these properties must be called the same as the column headers. You will also need to ensure that there is a public or protected parameterless constructor. public class ForumProfile : IForumProfile { public virtual int UserID { get; set; } public virtual string Twitter { get; set; } public virtual string Facebook { get; set; } public virtual string GooglePlus { get; set; } public virtual string LinkedIn { get; set; } public virtual string PublicEmailAddress { get; set; } public ForumProfile() { } }   The NHibernate Mapping File This is the XML I wrote in order to make NHibernate a) aware of the stored procedure, and b) aware of the expected results of the procedure. <?xml version="1.0" encoding="utf-8" ?> <hibernate-mapping xmlns="urn:nhibernate-mapping-2.2" namespace="[namespace]" assembly="[assembly]"> <sql-query name="GetForumProfileDetails"> <return-scalar column="UserID" type="Int32"/> <return-scalar column="Twitter" type="String"/> <return-scalar column="Facebook" type="String"/> <return-scalar column="GooglePlus" type="String"/> <return-scalar column="LinkedIn" type="String"/> <return-scalar column="PublicEmailAddress" type="String"/> exec GetForumProfileDetails :UserID </sql-query> </hibernate-mapping>   Calling the Stored Procedure Finally, to bring it all together, the C# code that I used in order to execute the stored procedure! public IForumProfile GetForumUserProfile(IUser user) { return NHibernateHelper .GetCurrentSession() .GetNamedQuery("GetForumProfileDetails") .SetInt32("UserID", user.UserID) .SetResultTransformer( Transformers.AliasToBean(typeof (ForumProfile))) .UniqueResult<ForumProfile>(); } There are a number of ‘Set’ methods (i.e. SetInt32) that allow you specify values for any parameters in the procedure. The AliasToBean method is then required to map the returned scalars (as specified in the XML) to the correct C# class.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Hibernate Exception, what wrong ? [[Exception in thread "main" org.hibernate.InvalidMappingException

    - by user195970
    I use netbean 6.7.1 to write "hello world" witch hibernate, but I get some errors, plz help me, thank you very much. my exception init: deps-module-jar: deps-ear-jar: deps-jar: Copying 1 file to F:\Documents and Settings\My Dropbox\DropboxNetBeanProjects\loginspring\build\web\WEB-INF\classes compile-single: run-main: Oct 25, 2009 2:44:05 AM org.hibernate.cfg.Environment <clinit> INFO: Hibernate 3.2.5 Oct 25, 2009 2:44:05 AM org.hibernate.cfg.Environment <clinit> INFO: hibernate.properties not found Oct 25, 2009 2:44:05 AM org.hibernate.cfg.Environment buildBytecodeProvider INFO: Bytecode provider name : cglib Oct 25, 2009 2:44:05 AM org.hibernate.cfg.Environment <clinit> INFO: using JDK 1.4 java.sql.Timestamp handling Oct 25, 2009 2:44:05 AM org.hibernate.cfg.Configuration configure INFO: configuring from resource: /hibernate.cfg.xml Oct 25, 2009 2:44:05 AM org.hibernate.cfg.Configuration getConfigurationInputStream INFO: Configuration resource: /hibernate.cfg.xml Oct 25, 2009 2:44:06 AM org.hibernate.cfg.Configuration addResource INFO: Reading mappings from resource : hibernate/Tbluser.hbm.xml Oct 25, 2009 2:44:06 AM org.hibernate.util.XMLHelper$ErrorLogger error SEVERE: Error parsing XML: XML InputStream(1) Document is invalid: no grammar found. Oct 25, 2009 2:44:06 AM org.hibernate.util.XMLHelper$ErrorLogger error SEVERE: Error parsing XML: XML InputStream(1) Document root element "hibernate-mapping", must match DOCTYPE root "null". Exception in thread "main" org.hibernate.InvalidMappingException: Could not parse mapping document from resource hibernate/Tbluser.hbm.xml at org.hibernate.cfg.Configuration.addResource(Configuration.java:569) at org.hibernate.cfg.Configuration.parseMappingElement(Configuration.java:1587) at org.hibernate.cfg.Configuration.parseSessionFactory(Configuration.java:1555) at org.hibernate.cfg.Configuration.doConfigure(Configuration.java:1534) at org.hibernate.cfg.Configuration.doConfigure(Configuration.java:1508) at org.hibernate.cfg.Configuration.configure(Configuration.java:1428) at org.hibernate.cfg.Configuration.configure(Configuration.java:1414) at hibernate.CreateTest.main(CreateTest.java:22) Caused by: org.hibernate.InvalidMappingException: Could not parse mapping document from invalid mapping at org.hibernate.cfg.Configuration.addInputStream(Configuration.java:502) at org.hibernate.cfg.Configuration.addResource(Configuration.java:566) ... 7 more Caused by: org.xml.sax.SAXParseException: Document is invalid: no grammar found. at com.sun.org.apache.xerces.internal.util.ErrorHandlerWrapper.createSAXParseException(ErrorHandlerWrapper.java:195) at com.sun.org.apache.xerces.internal.util.ErrorHandlerWrapper.error(ErrorHandlerWrapper.java:131) at com.sun.org.apache.xerces.internal.impl.XMLErrorReporter.reportError(XMLErrorReporter.java:384) at com.sun.org.apache.xerces.internal.impl.XMLErrorReporter.reportError(XMLErrorReporter.java:318) at com.sun.org.apache.xerces.internal.impl.XMLNSDocumentScannerImpl.scanStartElement(XMLNSDocumentScannerImpl.java:250) at com.sun.org.apache.xerces.internal.impl.XMLNSDocumentScannerImpl$NSContentDriver.scanRootElementHook(XMLNSDocumentScannerImpl.java:626) at com.sun.org.apache.xerces.internal.impl.XMLDocumentFragmentScannerImpl$FragmentContentDriver.next(XMLDocumentFragmentScannerImpl.java:3095) at com.sun.org.apache.xerces.internal.impl.XMLDocumentScannerImpl$PrologDriver.next(XMLDocumentScannerImpl.java:921) at com.sun.org.apache.xerces.internal.impl.XMLDocumentScannerImpl.next(XMLDocumentScannerImpl.java:648) at com.sun.org.apache.xerces.internal.impl.XMLNSDocumentScannerImpl.next(XMLNSDocumentScannerImpl.java:140) at com.sun.org.apache.xerces.internal.impl.XMLDocumentFragmentScannerImpl.scanDocument(XMLDocumentFragmentScannerImpl.java:510) at com.sun.org.apache.xerces.internal.parsers.XML11Configuration.parse(XML11Configuration.java:807) at com.sun.org.apache.xerces.internal.parsers.XML11Configuration.parse(XML11Configuration.java:737) at com.sun.org.apache.xerces.internal.parsers.XMLParser.parse(XMLParser.java:107) at com.sun.org.apache.xerces.internal.parsers.AbstractSAXParser.parse(AbstractSAXParser.java:1205) at com.sun.org.apache.xerces.internal.jaxp.SAXParserImpl$JAXPSAXParser.parse(SAXParserImpl.java:522) at org.dom4j.io.SAXReader.read(SAXReader.java:465) at org.hibernate.cfg.Configuration.addInputStream(Configuration.java:499) ... 8 more Java Result: 1 BUILD SUCCESSFUL (total time: 1 second) hibernate.cfg.xml <?xml version="1.0" encoding="UTF-8"?> <!DOCTYPE hibernate-configuration PUBLIC "-//Hibernate/Hibernate Configuration DTD 3.0//EN" "http://hibernate.sourceforge.net/hibernate-configuration-3.0.dtd"> <hibernate-configuration> <session-factory> <property name="hibernate.dialect">org.hibernate.dialect.MySQLDialect</property> <property name="hibernate.connection.driver_class">com.mysql.jdbc.Driver</property> <property name="hibernate.connection.url">jdbc:mysql://localhost:3306/hibernate</property> <property name="hibernate.connection.username">root</property> </session-factory> </hibernate-configuration> Tbluser.hbm.xml <?xml version="1.0"?> <!DOCTYPE hibernate-mapping PUBLIC "-//Hibernate/Hibernate Mapping DTD 3.0//EN" "http://hibernate.sourceforge.net/hibernate-mapping-3.0.dtd"> <!-- Generated Oct 25, 2009 2:37:30 AM by Hibernate Tools 3.2.1.GA --> <hibernate-mapping> <class name="hibernate.Tbluser" table="tbluser" catalog="hibernate"> <id name="userId" type="java.lang.Integer"> <column name="userID" /> <generator class="identity" /> </id> <property name="username" type="string"> <column name="username" length="50" /> </property> <property name="password" type="string"> <column name="password" length="50" /> </property> <property name="email" type="string"> <column name="email" length="50" /> </property> <property name="phone" type="string"> <column name="phone" length="50" /> </property> <property name="groupId" type="java.lang.Integer"> <column name="groupID" /> </property> </class> </hibernate-mapping> Tbluser.java package hibernate; // Generated Oct 25, 2009 2:37:30 AM by Hibernate Tools 3.2.1.GA /** * Tbluser generated by hbm2java */ public class Tbluser implements java.io.Serializable { private Integer userId; private String username; private String password; private String email; private String phone; private Integer groupId; public Tbluser() { } public Tbluser(String username, String password, String email, String phone, Integer groupId) { this.username = username; this.password = password; this.email = email; this.phone = phone; this.groupId = groupId; } public Integer getUserId() { return this.userId; } public void setUserId(Integer userId) { this.userId = userId; } public String getUsername() { return this.username; } public void setUsername(String username) { this.username = username; } public String getPassword() { return this.password; } public void setPassword(String password) { this.password = password; } public String getEmail() { return this.email; } public void setEmail(String email) { this.email = email; } public String getPhone() { return this.phone; } public void setPhone(String phone) { this.phone = phone; } public Integer getGroupId() { return this.groupId; } public void setGroupId(Integer groupId) { this.groupId = groupId; } }

    Read the article

  • IF adding new Entity gives error me : EntityCommandCompilationException was unhandled bu user code

    - by programmerist
    i have 5 tables in started projects. if i adds new table (Urun enttiy) writing below codes: project.BAL : public static List<Urun> GetUrun() { using (GenoTipSatisEntities genSatisUrunCtx = new GenoTipSatisEntities()) { ObjectQuery<Urun> urun = genSatisUrunCtx.Urun; return urun.ToList(); } } if i receive data form BAL in UI.aspx: using project.BAL; namespace GenoTip.Web.ContentPages.Satis { public partial class SatisUrun : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { if (!IsPostBack) { FillUrun(); } } void FillUrun() { ddlUrun.DataSource = SatisServices.GetUrun(); ddlUrun.DataValueField = "ID"; ddlUrun.DataTextField = "Ad"; ddlUrun.DataBind(); } } } i added URun later. error appears ToList method: EntityCommandCompilationException was unhandled bu user code error Detail: Error 1 Error 3007: Problem in Mapping Fragments starting at lines 659, 873: Non-Primary-Key column(s) [UrunID] are being mapped in both fragments to different conceptual side properties - data inconsistency is possible because the corresponding conceptual side properties can be independently modified. C:\Users\pc\Desktop\GenoTip.Satis\GenoTip.DAL\ModelSatis.edmx 660 15 GenoTip.DAL Error 2 Error 3012: Problem in Mapping Fragments starting at lines 659, 873: Data loss is possible in FaturaDetay.UrunID. An Entity with Key (PK) will not round-trip when: (PK does NOT play Role 'FaturaDetay' in AssociationSet 'FK_FaturaDetay_Urun' AND PK is in 'FaturaDetay' EntitySet) C:\Users\pc\Desktop\GenoTip.Satis\GenoTip.DAL\ModelSatis.edmx 874 11 GenoTip.DAL Error 3 Error 3012: Problem in Mapping Fragments starting at lines 659, 873: Data loss is possible in FaturaDetay.UrunID. An Entity with Key (PK) will not round-trip when: (PK is in 'FaturaDetay' EntitySet AND PK does NOT play Role 'FaturaDetay' in AssociationSet 'FK_FaturaDetay_Urun' AND Entity.UrunID is not NULL) C:\Users\pc\Desktop\GenoTip.Satis\GenoTip.DAL\ModelSatis.edmx 660 15 GenoTip.DAL Error 4 Error 3007: Problem in Mapping Fragments starting at lines 748, 879: Non-Primary-Key column(s) [UrunID] are being mapped in both fragments to different conceptual side properties - data inconsistency is possible because the corresponding conceptual side properties can be independently modified. C:\Users\pc\Desktop\GenoTip.Satis\GenoTip.DAL\ModelSatis.edmx 749 15 GenoTip.DAL Error 5 Error 3012: Problem in Mapping Fragments starting at lines 748, 879: Data loss is possible in Satis.UrunID. An Entity with Key (PK) will not round-trip when: (PK does NOT play Role 'Satis' in AssociationSet 'FK_Satis_Urun' AND PK is in 'Satis' EntitySet) C:\Users\pc\Desktop\GenoTip.Satis\GenoTip.DAL\ModelSatis.edmx 880 11 GenoTip.DAL Error 6 Error 3012: Problem in Mapping Fragments starting at lines 748, 879: Data loss is possible in Satis.UrunID. An Entity with Key (PK) will not round-trip when: (PK is in 'Satis' EntitySet AND PK does NOT play Role 'Satis' in AssociationSet 'FK_Satis_Urun' AND Entity.UrunID is not NULL) C:\Users\pc\Desktop\GenoTip.Satis\GenoTip.DAL\ModelSatis.edmx 749 15 GenoTip.DAL

    Read the article

  • NHibernate Master-Detail and Detail Deletion.

    - by JMSA
    Role.cs public class Role { public virtual string RoleName { get; set; } public virtual bool IsActive { get; set; } public virtual IList<Permission> PermissionItems { get; set; } } Role.hbm.xml <?xml version="1.0" encoding="utf-8" ?> <hibernate-mapping xmlns="urn:nhibernate-mapping-2.2" assembly="POCO" namespace="POCO"> <class name="Role" table="Role"> <id name="ID" column="ID"> <generator class="native" /> </id> <property name="RoleName" column="RoleName" /> <property name="IsActive" column="IsActive" type="System.Boolean" /> <bag name="PermissionItems" table="Permission" cascade="all" inverse="true"> <key column="RoleID"/> <one-to-many class="Permission" /> </bag> </class> </hibernate-mapping> Permission.cs public class Permission { public virtual string MenuItemKey { get; set; } public virtual int RoleID { get; set; } public virtual Role Role { get; set; } } Permission.hbm.xml <?xml version="1.0" encoding="utf-8" ?> <hibernate-mapping xmlns="urn:nhibernate-mapping-2.2" assembly="POCO" namespace="POCO"> <class name="Permission" table="Permission"> <id name="ID" column="ID"> <generator class="native"/> </id> <property name="MenuItemKey" column="MenuItemKey" /> <property name="RoleID" column="RoleID" /> <many-to-one name="Role" column="RoleID" not-null="true" cascade="all"> </many-to-one> </class> </hibernate-mapping> Suppose, I have saved some permissions in the database by using this code: RoleRepository roleRep = new RoleRepository(); Role role = new Role(); role.Permissions = Permission.GetList(); role.SaveOrUpdate(); Now, I need this code to delete all Permissions, since role.Permissions == null. Here is the code: RoleRepository roleRep = new RoleRepository(); Role role = roleRep.Get(roleId); role.Permissions = null; role.SaveOrUpdate(); But this is not happening. What should be the correct way to cope with this situation? What/how should I change, hbm-file or persistance code?

    Read the article

< Previous Page | 122 123 124 125 126 127 128 129 130 131 132 133  | Next Page >