Search Results

Search found 20099 results on 804 pages for 'virtual host'.

Page 129/804 | < Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >

  • Is it possible to setup a DHCP server only for local virtual machines?

    - by thiesdiggity
    I have a quick question. I have a bunch of virtual machines (VMWare Workstation) running on an Ubuntu server and have found that VMWare NAT (DHCP) service is unreliable and slow. I have to use NAT instead of bridging because the server is in a data-center that does not have DHCP and I don't have enough static IP's for all the VMs. Is it possible to setup the host (Ubuntu) to be a DHCP server but only for the local virtual machines? The server has 2 network interfaces, so I'd set eth0 to be a static IP, which connects to the outside world, and eth1 to listen for DHCP. Now, I am thinking if I don't want DHCP to broadcast I would just not connect a cable to eth1 and setup the VM's to use bridging on eth1. That way DHCP would not broadcast through my network but be listening on that interface. Would that setup work?

    Read the article

  • Is it possible to get free web host for my registered domain? [closed]

    - by Ahmed Alsayadi
    Possible Duplicate: How to find web hosting that meets my requirements? I searched online for many free web hosting websites like NetFirms, most of them asking you to register for their sub-domain or to buy a new domain, but I already have one which I bought through GoDaddy. Now I hope to find a free web host for my website (site's size less than 20 MB). Any idea which web hosting can meet such requirements?

    Read the article

  • Nagios notifications definitions

    - by Colin
    I am trying to monitor a web server in such a way that I want to search for a particular string on a page via http. The command is defined in command.cfg as follows # 'check_http-mysite command definition' define command { command_name check_http-mysite command_line /usr/lib/nagios/plugins/check_http -H mysite.example.com -s "Some text" } # 'notify-host-by-sms' command definition define command { command_name notify-host-by-sms command_line /usr/bin/send_sms $CONTACTPAGER$ "Nagios - $NOTIFICATIONTYPE$ :Host$HOSTALIAS$ is $HOSTSTATE$ ($OUTPUT$)" } # 'notify-service-by-sms' command definition define command { command_name notify-service-by-sms command_line /usr/bin/send_sms $CONTACTPAGER$ "Nagios - $NOTIFICATIONTYPE$: $HOSTALIAS$/$SERVICEDESC$ is $SERVICESTATE$ ($OUTPUT$)" } Now if nagios doesn't find "Some text" on the home page mysite.example.com, nagios should notify a contact via sms through the Clickatell http API which I have a script for that that I have tested and found that it works fine. Whenever I change the command definition to search for a string which is not on the page, and restart nagios, I can see on the web interface that the string was not found. What I don't understand is why isn't the notification sent though I have defined the host, hostgroup, contact, contactgroup and service and so forth. What I'm I missing, these are my definitions, In my web access through the cgi I can see that I have notifications have been defined and enabled though I don't get both email and sms notifications during hard status changes. host.cfg define host { use generic-host host_name HAL alias IBM-1 address xxx.xxx.xxx.xxx check_command check_http-mysite } *hostgroups_nagios2.cfg* # my website define hostgroup{ hostgroup_name my-servers alias All My Servers members HAL } *contacts_nagios2.cfg* define contact { contact_name colin alias Colin Y service_notification_period 24x7 host_notification_period 24x7 service_notification_options w,u,c,r,f,s host_notification_options d,u,r,f,s service_notification_commands notify-service-by-email,notify-service-by-sms host_notification_commands notify-host-by-email,notify-host-by-sms email [email protected] pager +254xxxxxxxxx } define contactgroup{ contactgroup_name site_admin alias Site Administrator members colin } *services_nagios2.cfg* # check for particular string in page via http define service { hostgroup_name my-servers service_description STRING CHECK check_command check_http-mysite use generic-service notification_interval 0 ; set > 0 if you want to be renotified contacts colin contact_groups site_admin } Could someone please tell me where I'm going wrong. Here are the generic-host and generic-service definitions *generic-service_nagios2.cfg* # generic service template definition define service{ name generic-service ; The 'name' of this service template active_checks_enabled 1 ; Active service checks are enabled passive_checks_enabled 1 ; Passive service checks are enabled/accepted parallelize_check 1 ; Active service checks should be parallelized (disabling this can lead to major performance problems) obsess_over_service 1 ; We should obsess over this service (if necessary) check_freshness 0 ; Default is to NOT check service 'freshness' notifications_enabled 1 ; Service notifications are enabled event_handler_enabled 1 ; Service event handler is enabled flap_detection_enabled 1 ; Flap detection is enabled failure_prediction_enabled 1 ; Failure prediction is enabled process_perf_data 1 ; Process performance data retain_status_information 1 ; Retain status information across program restarts retain_nonstatus_information 1 ; Retain non-status information across program restarts notification_interval 0 ; Only send notifications on status change by default. is_volatile 0 check_period 24x7 normal_check_interval 5 retry_check_interval 1 max_check_attempts 4 notification_period 24x7 notification_options w,u,c,r contact_groups site_admin register 0 ; DONT REGISTER THIS DEFINITION - ITS NOT A REAL SERVICE, JUST A TEMPLATE! } *generic-host_nagios2.cfg* define host{ name generic-host ; The name of this host template notifications_enabled 1 ; Host notifications are enabled event_handler_enabled 1 ; Host event handler is enabled flap_detection_enabled 1 ; Flap detection is enabled failure_prediction_enabled 1 ; Failure prediction is enabled process_perf_data 1 ; Process performance data retain_status_information 1 ; Retain status information across program restarts retain_nonstatus_information 1 ; Retain non-status information across program restarts max_check_attempts 10 notification_interval 0 notification_period 24x7 notification_options d,u,r contact_groups site_admin register 1 ; DONT REGISTER THIS DEFINITION - ITS NOT A REAL HOST, JUST A TEMPLATE! }

    Read the article

  • NTLM Authentication fails when behind Proxy server

    - by Jan Petersen
    Hi All, I've seen a number of post about consuming Web Services from behind a proxy server, but none that seams to address this problem. I'm building a desktop application, using Java, JAX-WS in NetBeans. I have a working prototype, that can query the server for authentication mode, successfully authenticate and retrieve a list of web site. However, if I run the same app from a network that is behind a proxy server (the proxy does not require authentication), then I'm running into trouble. I have sniffed the traffic, and noticed the following: Behind Proxy # Result Protocol Host URL 1 200 HTTP host.domain.com /_vti_bin/Authentication.asmx 2 401 HTTP host.domain.com /_vti_bin/Webs.asmx 3 401 HTTP host.domain.com /_vti_bin/Webs.asmx 4 401 HTTP host.domain.com /_vti_bin/Webs.asmx 5 401 HTTP host.domain.com /_vti_bin/Webs.asmx Without Proxy # Result Protocol Host URL 1 200 HTTP host.domain.com /_vti_bin/Authentication.asmx 2 401 HTTP host.domain.com /_vti_bin/Webs.asmx 3 401 HTTP host.domain.com /_vti_bin/Webs.asmx 4 401 HTTP host.domain.com /_vti_bin/Webs.asmx 5 401 HTTP host.domain.com /_vti_bin/Webs.asmx 6 200 HTTP host.domain.com /_vti_bin/Webs.asmx When running the code from a network without a proxy server, I successfully Authentication with the server, but when I'm behind the proxy server, the traffic is cut-off at the 5th message, and thus don't succeed. I know from the Java docs that On Microsoft Windows platforms, NTLM authentication attempts to acquire the user credentials from the system without prompting the user's authenticator object. If these credentials are not accepted by the server then the user's authenticator will be called. Given that my Authentication code is called only ones, and only as the 5th attempt, it appears as if the connection is dropped when behind the proxy server before my Authentication object is used. Is there any way I can control the behavior of Authentication module, to not have it use the system credentials? I have put the source text java class files of a demo app up, showing the issue at the following urls (it's a bit to long even in the short demo form to post here). link text Br Jan

    Read the article

  • Using WiX, how do I change a property of a subfolder of a virtual directory?

    - by Joergen Bech
    I have a hierarchy of Directory elements in a WiX script. I also have a component that creates a virtual directory (using IIS:WebVirtualDir), which points to the root of my Directory hierarchy. How do I change a property (e.g. AnonymousAccess) of a subfolder of the virtual directory, e.g. MyVirtualDir <<< this is the virtual directory root MyVirtualDir\MySubFolder <<< this is the subfolder for which I wish to change a property using WebDirProperties Please note that I do not wish to create a new virtual directory for the subfolder. I only wish to change a few security settings. The current script is too big to post here, but take a look at the WiX tutorial: 5.3 Web Directory. Suppose in that example that there was another Directory element named "MySubFolder" nested within the "InstallDir" element. What would then be the next step in order to set properties for "MySubFolder" without turning it into a virtual directory?

    Read the article

  • what is acceptable datastore latency on VMware ESXi host?

    - by BeowulfNode42
    Looking at our performance figures on our existing VMware ESXi 4.1 host at the Datastore/Real-time performance data Write Latency Avg 14 ms Max 41 ms Read Latency Avg 4.5 ms Max 12 ms People don't seem to be complaining too much about it being slow with those numbers. But how much higher could they get before people found it to be a problem? We are reviewing our head office systems due to running low on storage space, and are tossing up between buying a 2nd VM host with DAS or buying some sort of NAS for SMB file shares in the near term and maybe running VMs from it in the longer term. Currently we have just under 40 staff at head office with 9 smaller branches spread across the country. Head office is runnning in an MS RDS session based environment with linux ERP and mail systems. In total 22 VMs on a single host with DAS made from a RAID 10 made of 6x 15k SAS disks.

    Read the article

  • How do I make Linux recognize a new SATA /dev/sda drive I hot swapped in without rebooting?

    - by Philip Durbin
    Hot swapping out a failed SATA /dev/sda drive worked fine, but when I went to swap in a new drive, it wasn't recognized: [root@fs-2 ~]# tail -18 /var/log/messages May 5 16:54:35 fs-2 kernel: ata1: exception Emask 0x10 SAct 0x0 SErr 0x50000 action 0xe frozen May 5 16:54:35 fs-2 kernel: ata1: SError: { PHYRdyChg CommWake } May 5 16:54:40 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:45 fs-2 kernel: ata1: device not ready (errno=-16), forcing hardreset May 5 16:54:45 fs-2 kernel: ata1: soft resetting link May 5 16:54:50 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:55 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:54:55 fs-2 kernel: ata1: soft resetting link May 5 16:55:00 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:05 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:05 fs-2 kernel: ata1: soft resetting link May 5 16:55:10 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:40 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:40 fs-2 kernel: ata1: limiting SATA link speed to 1.5 Gbps May 5 16:55:40 fs-2 kernel: ata1: soft resetting link May 5 16:55:45 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:45 fs-2 kernel: ata1: reset failed, giving up May 5 16:55:45 fs-2 kernel: ata1: EH complete I tried a couple things to make the server find the new /dev/sda, such as rescan-scsi-bus.sh but they didn't work: [root@fs-2 ~]# echo "---" > /sys/class/scsi_host/host0/scan -bash: echo: write error: Invalid argument [root@fs-2 ~]# [root@fs-2 ~]# /root/rescan-scsi-bus.sh -l [snip] 0 new device(s) found. 0 device(s) removed. [root@fs-2 ~]# [root@fs-2 ~]# ls /dev/sda ls: /dev/sda: No such file or directory I ended up rebooting the server. /dev/sda was recognized, I fixed the software RAID, and everything is fine now. But for next time, how can I make Linux recognize a new SATA drive I have hot swapped in without rebooting? The operating system in question is RHEL5.3: [root@fs-2 ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.3 (Tikanga) The hard drive is a Seagate Barracuda ES.2 SATA 3.0-Gb/s 500-GB, model ST3500320NS. Here is the lscpi output: [root@fs-2 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0a.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0d.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0e.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) Update: In perhaps a dozen cases, we've been forced to reboot servers because hot swap hasn't "just worked." Thanks for the answers to look more into the SATA controller. I've included the lspci output for the problematic system above (hostname: fs-2). I could still use some help understanding what exactly isn't supported hardware-wise in terms of hot swap for that system. Please let me know what other output besides lspci might be useful. The good news is that hot swap "just worked" today on one of our servers (hostname: www-1), which is very rare for us. Here is the lspci output: [root@www-1 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:19.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 09:00.0 SCSI storage controller: LSI Logic / Symbios Logic SAS1064ET PCI-Express Fusion-MPT SAS (rev 04)

    Read the article

  • Two Network Adapters on Hyper-V Host - Best way to configure?

    - by GoNorthWest
    Hi, I have two physical network adapters installed in my Hyper-V host. I want one to be dedicated to the host, and the other to provide external network services to the VMs. Would the appropriate configuration be as such: Leave the first physical network adapter alone, assigning it the host IP, but not using it to create any Virtual Netorks For the second physical adapter, I would create an External Network, along with a Microsoft Virtual Switch, and use that to provide network services to the VMs. Each virtual NIC for the VM would be associated with that External Network. A static IP would be assigned to this adapter, and each VM would be assigned a static IP as well. The above seems reasonable to me, but I'm not sure if it's correct. Does anyone have any thoughts? Thanks! Mark

    Read the article

  • Microsoft VDI 2012 - VDI Personal collection vs Session-based deployment

    - by Vazgen
    I have a small confusion about the differences between the 2 types of set ups: When deploying using Add Roles and Features the Wizard requests to choose from one of two Deployment Scenarios: Virtual machine-based desktop deployment : Virtual machine-based desktop deployment allows users to connect to virtual desktop collections that include published RemoteApp programs and virtual desktops. Session-based desktop deployment : Session-based desktop deployment allows users to connect to session collections that include published RemoteApp programs and session-based desktops. Although this seems intuitive now, if I continue with "Virtual machine-based desktop deployment" I later have another two options when creating a collection: Pooled virtual desktop collection Personal virtual desktop collection This is where my confusion lies. What is the differences between a Session-based deployment and Virtual machine-based deployment with Personal virtual desktop collections? I'm mostly finding information pertaining to Windows Server 2008 but I know there are some core improvements in VDI 2012 so would someone please comment on that. Thank you

    Read the article

  • How do I make Linux recognize a new SATA /dev/sda drive I hot swapped in without rebooting?

    - by Philip Durbin
    Hot swapping out a failed SATA /dev/sda drive worked fine, but when I went to swap in a new drive, it wasn't recognized: [root@fs-2 ~]# tail -18 /var/log/messages May 5 16:54:35 fs-2 kernel: ata1: exception Emask 0x10 SAct 0x0 SErr 0x50000 action 0xe frozen May 5 16:54:35 fs-2 kernel: ata1: SError: { PHYRdyChg CommWake } May 5 16:54:40 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:45 fs-2 kernel: ata1: device not ready (errno=-16), forcing hardreset May 5 16:54:45 fs-2 kernel: ata1: soft resetting link May 5 16:54:50 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:55 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:54:55 fs-2 kernel: ata1: soft resetting link May 5 16:55:00 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:05 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:05 fs-2 kernel: ata1: soft resetting link May 5 16:55:10 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:40 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:40 fs-2 kernel: ata1: limiting SATA link speed to 1.5 Gbps May 5 16:55:40 fs-2 kernel: ata1: soft resetting link May 5 16:55:45 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:45 fs-2 kernel: ata1: reset failed, giving up May 5 16:55:45 fs-2 kernel: ata1: EH complete I tried a couple things to make the server find the new /dev/sda, such as rescan-scsi-bus.sh but they didn't work: [root@fs-2 ~]# echo "---" > /sys/class/scsi_host/host0/scan -bash: echo: write error: Invalid argument [root@fs-2 ~]# [root@fs-2 ~]# /root/rescan-scsi-bus.sh -l [snip] 0 new device(s) found. 0 device(s) removed. [root@fs-2 ~]# [root@fs-2 ~]# ls /dev/sda ls: /dev/sda: No such file or directory I ended up rebooting the server. /dev/sda was recognized, I fixed the software RAID, and everything is fine now. But for next time, how can I make Linux recognize a new SATA drive I have hot swapped in without rebooting? The operating system in question is RHEL5.3: [root@fs-2 ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.3 (Tikanga) The hard drive is a Seagate Barracuda ES.2 SATA 3.0-Gb/s 500-GB, model ST3500320NS. Here is the lscpi output: [root@fs-2 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0a.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0d.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0e.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) Update: In perhaps a dozen cases, we've been forced to reboot servers because hot swap hasn't "just worked." Thanks for the answers to look more into the SATA controller. I've included the lspci output for the problematic system above (hostname: fs-2). I could still use some help understanding what exactly isn't supported hardware-wise in terms of hot swap for that system. Please let me know what other output besides lspci might be useful. The good news is that hot swap "just worked" today on one of our servers (hostname: www-1), which is very rare for us. Here is the lspci output: [root@www-1 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:19.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 09:00.0 SCSI storage controller: LSI Logic / Symbios Logic SAS1064ET PCI-Express Fusion-MPT SAS (rev 04)

    Read the article

  • Can I temporarily leave other roles active when converting a 2008 R2 server to a hyper-v host?

    - by Eric
    I currently have a Windows 2008 R2 box that I want to convert to a hyper-v host. Currently I have the following running on it: File Services, Web Server (IIS), and Sql Server 2008 R2 with a few different DBs. In the long term, I'd like to move all of those over to the VMs that will be created. However, in the short term I'd like to leave them running on the server. Are there any complications/problems with leaving them running on the hyper-v server for a day or two? How long will those services typically go down during the addition of the hyper-v role? Right now my plan is to back up everything, enable the hyper-v role, set up VMs, and migrate stuff off of the host. However, if there is a good probability that something may cease to function I might need to migrate everything over to a temporary host before doing the conversion.

    Read the article

  • Cacti is not monitoring the correct host... How do I change SNMP target?

    - by wil
    I have been handed a Cacti server that monitors a few hosts. I noticed that three of the targets were displaying the exact same data - the cacti machine, machine a and machine b. After doing a bit of digging, I noticed that machine a and machine b had "Local Linux Machine" set under "Host Template". I have since changed the host template to "Generic SNMP-enabled Host", however, all the graphs still only display data from the local cacti machine (Updates every 5 minutes - I changed this yesterday - 12 hours). I can't think what else is wrong and was wondering if anyone knows/can recommend anything?

    Read the article

  • Virtual PC "The page cannot be displayed" error connecting to iis7.5 site on Win7 host.

    - by stan
    I setup virtual pc with the Windows XP IE6 VHD to test a site on Windows 7 host. I created a loopback adapter connection on the host. I have several sites on IIS 7.5, I'm able to connect to all of them except one. And it's the site I need to test... I get "The page cannot be displayed" error. The site loads fine from the host(Windows 7). I've made sure the permissions match that of the other sites that do load. I've recreated the application in IIS manager. Does anyone know what the problem might be?

    Read the article

  • AppFabric named cache, what happens if you lose a cache host?

    - by Liam
    I'm getting my head around how app fabric clustering works and there's something I'm not sure about. Given a structure where we have one named cache, with two lead hosts and (say) three cache hosts and high availability turned off and the lead host(s) performing the management role. When one cache host goes down do you loose the data that was on that cache host? In this MSDN article it states: Data on the non-lead hosts would be lost (assuming high availability was not enabled), but the rest of the cluster could continue serving and storing data But I was unsure if redundancy is built into the system. Would you loose x amount of data or would one of the other cache hosts store this data also and pick up the slack?

    Read the article

  • Two Network Adapters on Hyper-V Host - Best way to configure?

    - by GoNorthWest
    I have two physical network adapters installed in my Hyper-V host. I want one to be dedicated to the host, and the other to provide external network services to the VMs. Would the appropriate configuration be as such: Leave the first physical network adapter alone, assigning it the host IP, but not using it to create any Virtual Netorks For the second physical adapter, I would create an External Network, along with a Microsoft Virtual Switch, and use that to provide network services to the VMs. Each virtual NIC for the VM would be associated with that External Network. A static IP would be assigned to this adapter, and each VM would be assigned a static IP as well. The above seems reasonable to me, but I'm not sure if it's correct. Does anyone have any thoughts? Thanks! Mark

    Read the article

  • Should the virtualization host be allowed to run any service?

    - by Giordano
    I recently setup a virtualization server for the small company I'm running. This server runs few virtual machines that are used for development, testing, etc... My business partner works from a remote location, thus I also installed a vpn server on the virtualization host to make it possible for him to safely reach the company services. Moreover, again on the virtualization host, I installed bacula to perform the backup of the data. Is it advisable/good practice to do so or should I create one more virtual machine to do backups and VPN? Is it a bad idea to run these services on the host itself? If yes, why? Thanks in advance!

    Read the article

  • What's up with LDoms: Part 1 - Introduction & Basic Concepts

    - by Stefan Hinker
    LDoms - the correct name is Oracle VM Server for SPARC - have been around for quite a while now.  But to my surprise, I get more and more requests to explain how they work or to give advise on how to make good use of them.  This made me think that writing up a few articles discussing the different features would be a good idea.  Now - I don't intend to rewrite the LDoms Admin Guide or to copy and reformat the (hopefully) well known "Beginners Guide to LDoms" by Tony Shoumack from 2007.  Those documents are very recommendable - especially the Beginners Guide, although based on LDoms 1.0, is still a good place to begin with.  However, LDoms have come a long way since then, and I hope to contribute to their adoption by discussing how they work and what features there are today.  In this and the following posts, I will use the term "LDoms" as a common abbreviation for Oracle VM Server for SPARC, just because it's a lot shorter and easier to type (and presumably, read). So, just to get everyone on the same baseline, lets briefly discuss the basic concepts of virtualization with LDoms.  LDoms make use of a hypervisor as a layer of abstraction between real, physical hardware and virtual hardware.  This virtual hardware is then used to create a number of guest systems which each behave very similar to a system running on bare metal:  Each has its own OBP, each will install its own copy of the Solaris OS and each will see a certain amount of CPU, memory, disk and network resources available to it.  Unlike some other type 1 hypervisors running on x86 hardware, the SPARC hypervisor is embedded in the system firmware and makes use both of supporting functions in the sun4v SPARC instruction set as well as the overall CPU architecture to fulfill its function. The CMT architecture of the supporting CPUs (T1 through T4) provide a large number of cores and threads to the OS.  For example, the current T4 CPU has eight cores, each running 8 threads, for a total of 64 threads per socket.  To the OS, this looks like 64 CPUs.  The SPARC hypervisor, when creating guest systems, simply assigns a certain number of these threads exclusively to one guest, thus avoiding the overhead of having to schedule OS threads to CPUs, as do typical x86 hypervisors.  The hypervisor only assigns CPUs and then steps aside.  It is not involved in the actual work being dispatched from the OS to the CPU, all it does is maintain isolation between different guests. Likewise, memory is assigned exclusively to individual guests.  Here,  the hypervisor provides generic mappings between the physical hardware addresses and the guest's views on memory.  Again, the hypervisor is not involved in the actual memory access, it only maintains isolation between guests. During the inital setup of a system with LDoms, you start with one special domain, called the Control Domain.  Initially, this domain owns all the hardware available in the system, including all CPUs, all RAM and all IO resources.  If you'd be running the system un-virtualized, this would be what you'd be working with.  To allow for guests, you first resize this initial domain (also called a primary domain in LDoms speak), assigning it a small amount of CPU and memory.  This frees up most of the available CPU and memory resources for guest domains.  IO is a little more complex, but very straightforward.  When LDoms 1.0 first came out, the only way to provide IO to guest systems was to create virtual disk and network services and attach guests to these services.  In the meantime, several different ways to connect guest domains to IO have been developed, the most recent one being SR-IOV support for network devices released in version 2.2 of Oracle VM Server for SPARC. I will cover these more advanced features in detail later.  For now, lets have a short look at the initial way IO was virtualized in LDoms: For virtualized IO, you create two services, one "Virtual Disk Service" or vds, and one "Virtual Switch" or vswitch.  You can, of course, also create more of these, but that's more advanced than I want to cover in this introduction.  These IO services now connect real, physical IO resources like a disk LUN or a networt port to the virtual devices that are assigned to guest domains.  For disk IO, the normal case would be to connect a physical LUN (or some other storage option that I'll discuss later) to one specific guest.  That guest would be assigned a virtual disk, which would appear to be just like a real LUN to the guest, while the IO is actually routed through the virtual disk service down to the physical device.  For network, the vswitch acts very much like a real, physical ethernet switch - you connect one physical port to it for outside connectivity and define one or more connections per guest, just like you would plug cables between a real switch and a real system. For completeness, there is another service that provides console access to guest domains which mimics the behavior of serial terminal servers. The connections between the virtual devices on the guest's side and the virtual IO services in the primary domain are created by the hypervisor.  It uses so called "Logical Domain Channels" or LDCs to create point-to-point connections between all of these devices and services.  These LDCs work very similar to high speed serial connections and are configured automatically whenever the Control Domain adds or removes virtual IO. To see all this in action, now lets look at a first example.  I will start with a newly installed machine and configure the control domain so that it's ready to create guest systems. In a first step, after we've installed the software, let's start the virtual console service and downsize the primary domain.  root@sun # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-c-- UART 512 261632M 0.3% 2d 13h 58m root@sun # ldm add-vconscon port-range=5000-5100 \ primary-console primary root@sun # svcadm enable vntsd root@sun # svcs vntsd STATE STIME FMRI online 9:53:21 svc:/ldoms/vntsd:default root@sun # ldm set-vcpu 16 primary root@sun # ldm set-mau 1 primary root@sun # ldm start-reconf primary root@sun # ldm set-memory 7680m primary root@sun # ldm add-config initial root@sun # shutdown -y -g0 -i6 So what have I done: I've defined a range of ports (5000-5100) for the virtual network terminal service and then started that service.  The vnts will later provide console connections to guest systems, very much like serial NTS's do in the physical world. Next, I assigned 16 vCPUs (on this platform, a T3-4, that's two cores) to the primary domain, freeing the rest up for future guest systems.  I also assigned one MAU to this domain.  A MAU is a crypto unit in the T3 CPU.  These need to be explicitly assigned to domains, just like CPU or memory.  (This is no longer the case with T4 systems, where crypto is always available everywhere.) Before I reassigned the memory, I started what's called a "delayed reconfiguration" session.  That avoids actually doing the change right away, which would take a considerable amount of time in this case.  Instead, I'll need to reboot once I'm all done.  I've assigned 7680MB of RAM to the primary.  That's 8GB less the 512MB which the hypervisor uses for it's own private purposes.  You can, depending on your needs, work with less.  I'll spend a dedicated article on sizing, discussing the pros and cons in detail. Finally, just before the reboot, I saved my work on the ILOM, to make this configuration available after a powercycle of the box.  (It'll always be available after a simple reboot, but the ILOM needs to know the configuration of the hypervisor after a power-cycle, before the primary domain is booted.) Now, lets create a first disk service and a first virtual switch which is connected to the physical network device igb2. We will later use these to connect virtual disks and virtual network ports of our guest systems to real world storage and network. root@sun # ldm add-vds primary-vds root@sun # ldm add-vswitch net-dev=igb2 switch-primary primary You are free to choose whatever names you like for the virtual disk service and the virtual switch.  I strongly recommend that you choose names that make sense to you and describe the function of each service in the context of your implementation.  For the vswitch, for example, you could choose names like "admin-vswitch" or "production-network" etc. This already concludes the configuration of the control domain.  We've freed up considerable amounts of CPU and RAM for guest systems and created the necessary infrastructure - console, vts and vswitch - so that guests systems can actually interact with the outside world.  The system is now ready to create guests, which I'll describe in the next section. For further reading, here are some recommendable links: The LDoms 2.2 Admin Guide The "Beginners Guide to LDoms" The LDoms Information Center on MOS LDoms on OTN

    Read the article

  • Powershell: Install-dotNET4 function

    - by marc dekeyser
    This function will download and install ,NET 4.0. It uses the Get-Framework-Versions function to determine if the installation is necessary or not. Internet Connectivity will be required as the script auto downloads the setup file (and sleeps for 360 seconds... I had a function in there to monitor for install completion at first, turns out the setup file spawns so many childprocesses the function just got confused and locked up -_-)Alternatively you could drop the installation file in the folder specified on the $folderPath variable too. That will skip the download and use the file. This function easily adapts in to other versions f.e. I use it for Powershell 3 installs as well!Function install-dotNet4 () {    if(($InstalledDotNET -eq "4.0") -or ($InstalledDotNET -eq "4.0c")){        write-host ".NET 4.0 Framework is already installed" -foregroundcolor Green    } else{            #set a var for the folder you are looking for        $folderPath = 'C:\Temp'        #Check if folder exists, if not, create it        if (Test-Path $folderpath){            Write-Host "The folder $folderPath exists." -ForeGroundColor Green        } else{            Write-Host "The folder $folderPath does not exist, creating..." -NoNewline -ForegroundColor Red            New-Item $folderpath -type directory | Out-Null            Write-Host " - done!" -ForegroundColor Green        }        # Check if file exists, if not, download it        $file = $folderPath+"\dotNetFx40_Full_x86_x64.exe"        if (Test-Path $file){            write-host "The file $file exists." -ForeGroundColor Green        } else {            #Download Microsoft .Net 4.0 Framework            Write-Host "Downloading Microsoft .Net 4.0 Framework..." -nonewline -ForeGroundColor DarkYellow            $clnt = New-Object System.Net.WebClient            $url = "http://download.microsoft.com/download/9/5/A/95A9616B-7A37-4AF6-BC36-D6EA96C8DAAE/dotNetFx40_Full_x86_x64.exe"            $clnt.DownloadFile($url,$file)            Write-Host " - done!" -ForegroundColor Green        }        #Install Microsoft .Net Framework        Write-Host "Installing Microsoft .Net Framework..." -nonewline -ForegroundColor DarkYellow        $dotNET4 = $folderPath+"\dotNetFx40_Full_x86_x64.exe /quiet /norestart"        Invoke-Expression $dotNET4        write-host " - done!" -ForegroundColor Green        start-sleep -seconds 360    }}

    Read the article

  • Can't install the wireless driver in HP Pavilion dv2419us

    - by maqtanim
    I've just installed Ubuntu 13.04 in an old HP Pavilion dv2419us. The problem is, Ubuntu doesn't detect the wireless card. But it works fine in Windows 7. The following command returns nothing! lspci -vvnn | grep 14e4 And the lspci output is: 00:00.1 RAM memory: NVIDIA Corporation C51 Memory Controller 0 (rev a2) 00:00.2 RAM memory: NVIDIA Corporation C51 Memory Controller 1 (rev a2) 00:00.3 RAM memory: NVIDIA Corporation C51 Memory Controller 5 (rev a2) 00:00.4 RAM memory: NVIDIA Corporation C51 Memory Controller 4 (rev a2) 00:00.5 RAM memory: NVIDIA Corporation C51 Host Bridge (rev a2) 00:00.6 RAM memory: NVIDIA Corporation C51 Memory Controller 3 (rev a2) 00:00.7 RAM memory: NVIDIA Corporation C51 Memory Controller 2 (rev a2) 00:02.0 PCI bridge: NVIDIA Corporation C51 PCI Express Bridge (rev a1) 00:03.0 PCI bridge: NVIDIA Corporation C51 PCI Express Bridge (rev a1) 00:05.0 VGA compatible controller: NVIDIA Corporation C51 [GeForce Go 6150] (rev a2) 00:09.0 RAM memory: NVIDIA Corporation MCP51 Host Bridge (rev a2) 00:0a.0 ISA bridge: NVIDIA Corporation MCP51 LPC Bridge (rev a3) 00:0a.1 SMBus: NVIDIA Corporation MCP51 SMBus (rev a3) 00:0a.3 Co-processor: NVIDIA Corporation MCP51 PMU (rev a3) 00:0b.0 USB controller: NVIDIA Corporation MCP51 USB Controller (rev a3) 00:0b.1 USB controller: NVIDIA Corporation MCP51 USB Controller (rev a3) 00:0d.0 IDE interface: NVIDIA Corporation MCP51 IDE (rev f1) 00:0e.0 IDE interface: NVIDIA Corporation MCP51 Serial ATA Controller (rev f1) 00:10.0 PCI bridge: NVIDIA Corporation MCP51 PCI Bridge (rev a2) 00:10.1 Audio device: NVIDIA Corporation MCP51 High Definition Audio (rev a2) 00:14.0 Bridge: NVIDIA Corporation MCP51 Ethernet Controller (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 05:09.0 FireWire (IEEE 1394): Ricoh Co Ltd R5C832 IEEE 1394 Controller 05:09.1 SD Host controller: Ricoh Co Ltd R5C822 SD/SDIO/MMC/MS/MSPro Host Adapter (rev 19) 05:09.2 System peripheral: Ricoh Co Ltd R5C592 Memory Stick Bus Host Adapter (rev 0a) 05:09.3 System peripheral: Ricoh Co Ltd xD-Picture Card Controller (rev 05) The command lspci -nn | grep 0280 gives no output. Any suggestion regarding this?

    Read the article

  • Computer becomes unreachable on lan after some time

    - by Ashfame
    I work on my laptop and ssh into my desktop. I use a lot of key based authentication for many servers for work but recently I couldn't login because ssh would pick up and try all the keys and it stops trying before ultimately falling back to password based login. So right now I am using this command: ssh -X -o PubkeyAuthentication=no [email protected] #deskto The issue is after sometime the desktop would just become unreachable from laptop. I won't be able to open its localhost through IP and today I tried ping'in it and found a weird thing. Instead of 192.168.1.4, it tries to ping 192.168.1.3 which I am sure is the root cause as it just can't reach 192.168.1.4 when its actually trying for 192.168.1.3 Ping command output: ashfame@ashfame-xps:~$ ping 192.168.1.4 PING 192.168.1.4 (192.168.1.4) 56(84) bytes of data. From 192.168.1.3 icmp_seq=1 Destination Host Unreachable From 192.168.1.3 icmp_seq=2 Destination Host Unreachable From 192.168.1.3 icmp_seq=3 Destination Host Unreachable From 192.168.1.3 icmp_seq=4 Destination Host Unreachable From 192.168.1.3 icmp_seq=5 Destination Host Unreachable From 192.168.1.3 icmp_seq=6 Destination Host Unreachable From 192.168.1.3 icmp_seq=7 Destination Host Unreachable From 192.168.1.3 icmp_seq=8 Destination Host Unreachable From 192.168.1.3 icmp_seq=9 Destination Host Unreachable ^C --- 192.168.1.4 ping statistics --- 10 packets transmitted, 0 received, +9 errors, 100% packet loss, time 9047ms pipe 3 Also the ping command message comes in multiple and not one by one. (izx answer's the weirdness I thought there was in ping command.) I did check for desktop, its local IP is still the same, so something is going on in my laptop. Any ideas? P.S. - Laptop runs Ubuntu 12.04 & Desktop runs Ubuntu 11.10 Laptop is connected through wifi to router and Desktop is connected through LAN to router. Update: Even after setting up static IP leases in router settings, I again ran into this issue.

    Read the article

  • How to bridge Debian guest VM to VPN via Cisco AnyConnect Client running on Windows Vista host

    - by bgoodr
    I am running Cisco Anyconnect VPN Client version 2.5.3054 on a laptop running Windows Vista Home Premium (version 6.0.6002) Service Pack 2. I am running the VMware Player version 4.0.2 build-591240. The host operating system running under VMware Player is Debian 6.0.2.1 i386. The laptop is connected to a wireless connection, and I can browse the web from Windows Vista using Firefox just fine. I am able to boot into the Debian VM and open up a browser and access websites on the WAN from within the VM just fine. I can ping real Linux hosts on my LAN via: ping <lan_system>.local where <lan_system> is the hostname returned from uname -a on that system on my LAN. From a DOS CMD shell, I am able to ping hosts that exist on the remote network served by the Cisco AnyConnect Client's VPN network (and without the .local suffix applied as above): ping <remote_system> However, from within the Debian VM, I expect to be able to also ping those same remote hosts (<remote_system>) that are tunnelled over the VPN set up by Cisco AnyConnect Client. Let's say that I can ping a <remote_system> called flubber from a DOS CMD prompt just fine. When I execute Linux ping command from inside the Debian VM via: ping flubber It returns immediately with this output: ping: unknown host flubber For reference since I suspect it will be useful, here is the output of the route print command from the DOS CMD prompt: route print =========================================================================== Interface List 30 ...00 05 9a 3c 7a 00 ...... Cisco AnyConnect VPN Virtual Miniport Adapter for Windows 11 ...00 1b 9e c4 de e5 ...... Atheros AR5007EG Wireless Network Adapter 26 ...00 50 56 c0 00 01 ...... VMware Virtual Ethernet Adapter for VMnet1 28 ...00 50 56 c0 00 08 ...... VMware Virtual Ethernet Adapter for VMnet8 1 ........................... Software Loopback Interface 1 12 ...02 00 54 55 4e 01 ...... Teredo Tunneling Pseudo-Interface 13 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #3 32 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #4 27 ...00 00 00 00 00 00 00 e0 isatap.{E5292CF6-4FBB-4320-806D-A6B366769255} 17 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #2 20 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #8 22 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #10 24 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #11 25 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #12 29 ...00 00 00 00 00 00 00 e0 isatap.{C3852986-5053-4E2E-BE60-52EA2FCF5899} 41 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #14 =========================================================================== At the top window border of the VM, clicking on Virtual Machine, then clicking on Virtual Machine Settings, then clicking on Network Adapter, I have these two options checked: [X] Bridged: Connected directly to the physical Network [X] Replicate physical network connection state [ ] NAT: used to share the hosts's IP address [ ] Host-only: A private network shared with the host [ ] LAN segment: [ ] <LAN Segments...> <Advanced> I've toyed with the other options such as NAT and Host-only but that had no effect. Is there some way to allow the VM to access those <remote_system>'s?

    Read the article

  • KVM guest io is much slower than host io: is that normal?

    - by Evolver
    I have a Qemu-KVM host system setup on CentOS 6.3. Four 1TB SATA HDDs working in Software RAID10. Guest CentOS 6.3 is installed on separate LVM. People say that they see guest performance almost equal to host performance, but I don't see that. My i/o tests are showing 30-70% slower performance on guest than on host system. I tried to change scheduler (set elevator=deadline on host and elevator=noop on guest), set blkio.weight to 1000 in cgroup, change io to virtio... But none of these changes gave me any significant results. This is a guest .xml config part: <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/dev/vgkvmnode/lv2'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </disk> There are my tests: Host system: iozone test # iozone -a -i0 -i1 -i2 -s8G -r64k random random KB reclen write rewrite read reread read write 8388608 64 189930 197436 266786 267254 28644 66642 dd read test: one process and then four simultaneous processes # dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct 1073741824 bytes (1.1 GB) copied, 4.23044 s, 254 MB/s # dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=1024 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=2048 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=3072 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=4096 1073741824 bytes (1.1 GB) copied, 14.4528 s, 74.3 MB/s 1073741824 bytes (1.1 GB) copied, 14.562 s, 73.7 MB/s 1073741824 bytes (1.1 GB) copied, 14.6341 s, 73.4 MB/s 1073741824 bytes (1.1 GB) copied, 14.7006 s, 73.0 MB/s dd write test: one process and then four simultaneous processes # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 6.2039 s, 173 MB/s # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test2 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test3 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test4 bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 32.7173 s, 32.8 MB/s 1073741824 bytes (1.1 GB) copied, 32.8868 s, 32.6 MB/s 1073741824 bytes (1.1 GB) copied, 32.9097 s, 32.6 MB/s 1073741824 bytes (1.1 GB) copied, 32.9688 s, 32.6 MB/s Guest system: iozone test # iozone -a -i0 -i1 -i2 -s512M -r64k random random KB reclen write rewrite read reread read write 524288 64 93374 154596 141193 149865 21394 46264 dd read test: one process and then four simultaneous processes # dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=1024 1073741824 bytes (1.1 GB) copied, 5.04356 s, 213 MB/s # dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=1024 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=2048 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=3072 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=4096 1073741824 bytes (1.1 GB) copied, 24.7348 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.7378 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.7408 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.744 s, 43.4 MB/s dd write test: one process and then four simultaneous processes # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 10.415 s, 103 MB/s # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test2 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test3 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test4 bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 49.8874 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.8608 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.8693 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.9427 s, 21.5 MB/s I wonder is that normal situation or did I missed something?

    Read the article

  • Configure IPv6 routing

    - by godlark
    I've got IPv6 addresses from SIXXS. My host is connected with SIXXS network over a AICCU tunnel ("sixxs" interface). My host address is 2001:::2, the host on the end has address 2001:::1. On my host IPv6 is fully accessible. I have problem with configuring IPv6 network on VMs. I use VirtualBox, the VM (Ubuntu) uses tap1 (on the host bridged by br0) #!/bin/sh PATH=/sbin:/usr/bin:/bin:/usr/bin:/usr/sbin # create a tap tunctl -t tap1 ip link set up dev tap1 # create the bridge brctl addbr br0 brctl addif br0 tap1 # set the IP address and routing ip link set up dev br0 ip -6 route del 2001:6a0:200:172::/64 dev sixxs ip -6 route add 2001:6a0:200:172::1 dev sixxs ip -6 addr add 2001:6a0:200:172::2/64 dev br0 ip -6 route add 2001:6a0:200:172::2/64 dev br0 Host: routing table: 2001:6a0:200:172::1 dev sixxs metric 1024 2001:6a0:200:172::/64 dev br0 proto kernel metric 256 2001:6a0:200:172::/64 dev br0 metric 1024 2000::/3 dev sixxs metric 1024 fe80::/64 dev eth0 proto kernel metric 256 fe80::/64 dev sixxs proto kernel metric 256 fe80::/64 dev br0 proto kernel metric 256 fe80::/64 dev tap1 proto kernel metric 256 default via 2001:6a0:200:172::1 dev sixxs metric 1024 Guest: interface eth1 (it is connected with tap1): auto eth1 iface eth1 inet6 static address 2001:6a0:200:172::3 netmask 64 gateway 2001:6a0:200:172::2 Guest: routing table 2001:6a0:200:172::/64 dev eth1 proto kernel metric 256 fe80::/64 dev eth0 proto kernel metric 256 fe80::/64 dev eth1 proto kernel metric 256 default via 2001:6a0:200:172::2 dev eth1 metric 1024 The guest pings to the host, the host pings to the guest, the host pings to 2001:6a0:200:172::1, but the guest doesn't ping to 2001:6a0:200:172::1. The guest tries to ping, on the host (by tcdump) I can capture its packets, but the host doesn't send them to 2001:6a0:200:172::1. What have I missed in configuration?

    Read the article

  • Why does nmap ping scan over a VPN link return all hosts alive?

    - by ewwhite
    I'm curious as to why running an nmap -sP (ping scan) on a remote subnet linked via a Cisco site-to-site IPSec tunnel returns "host up" status for every IP in the range. [root@xt ~]# nmap -sP 192.168.108.* Starting Nmap 4.11 ( http://www.insecure.org/nmap/ ) at 2012-11-22 14:08 CST Host 192.168.108.0 appears to be up. Host 192.168.108.1 appears to be up. Host 192.168.108.2 appears to be up. Host 192.168.108.3 appears to be up. Host 192.168.108.4 appears to be up. Host 192.168.108.5 appears to be up. . . . Host 192.168.108.252 appears to be up. Host 192.168.108.253 appears to be up. Host 192.168.108.254 appears to be up. Host 192.168.108.255 appears to be up. Nmap finished: 256 IP addresses (256 hosts up) scanned in 14.830 seconds However, a ping of a known-down IP simply times out or doesn't return anything... [root@xt ~]# ping 192.168.108.201 PING 192.168.108.201 (192.168.108.201) 56(84) bytes of data. --- 192.168.108.201 ping statistics --- 144 packets transmitted, 0 received, 100% packet loss, time 143001ms Is there a more effective way to scan live devices connected in this manner?

    Read the article

  • Taking advantage of Windows Azure CDN and Dynamic Pages in ASP.NET - Caching content from hosted services

    - by Shawn Cicoria
    With the updates to Windows Azure CDN announced this week [1] I wanted to help illustrate the capability with a working sample that will serve up dynamic content from an ASP.NET site hosted in a WebRole. First, to get a good overview of the capability you can read the Overview of the Windows Azure CDN [2] content on MSDN. When you setup the ability to cache content from a hosted service, the requirement is to provide a path to your role’s DNS endpoint that ends in the path “/cdn”.  Additionally, you then map CDN to that service. What WAZ CDN does, is allow you to then map that through the CDN to your host.  The CDN will then make a request to your host on your client’s behalf. The requirement is still that your client, and any Url’s that are to be serviced through the CDN and this capability have to use the CDN DNS name and not your host – no different than what CDN does for Blog storage. The following 2 URL’s are samples of how the client needs to issue the requests. Windows Azure hosted service URL: http: //myHostedService.cloudapp.net/cdn/music.aspx   - for regular “dynamic” content Windows Azure CDN URL: http: //<identifier>.vo.msecnd.net/music.aspx   - for CDN “cachable” content. The first URL path’s the request direct to your host into the Azure datacenter.  The 2nd URL paths the request through the CDN infrastructure, where CDN will make the determination to request the content on behalf of the client to the Azure datacenter and your host on the /cdn path. The big advantage here is you can apply logic to your content creation.  What’s important is emitting the CDN friendly headers that allow CDN to request and re-request only when you designate based upon it’s rules of “staleness” as described in the overview page. With IIS7.5 there is an underlying issue when the Managed Module “OutputCache” is enabled that in order to emit a good header for your content, you’ll need to remove, and in my sample, helps provide CDN friendly headers.  You get IIS 7.5 when running under OS Family “2” in your service configuration. By default, and when the OutputCache managed module is loaded, if you use the HttpResponse.CachePolicy to set the Http Headers for “max-age” when the HttpCacheability is “Public”, you will NOT get the “max-age” emitted as part of the “Cache-control:” header.  Instead, the OutputCache module will remove “max-age” and just emit “public”.  It works ok when Cacheability is set to “private”. To work around the issue and ensure your code as follows emits the full max-age along with the public option, you need to remove as follows: <system.webServer>   <modules runAllManagedModulesForAllRequests="true">     <remove name="OutputCache"/>   </modules> </system.webServer>   Response.Cache.SetCacheability(HttpCacheability.Public); Response.Cache.SetMaxAge(TimeSpan.FromMinutes(rv));   In the attached solution, the way I approached it was to have a VirtualApplication under the root site that has it’s own web.config  - this VirtualApplication is the /cdn of the site and when deployed to Azure as a Web Role will surface as a distinct IIS Application – along with a separate AppDomain. The CDN Sample is a simple Web Forms site that the /default landing page contains 3 IFrames to host: 1. Content direct from the host @   http://xxxx.cloudapp.net/cdn 2. Content via the CDN @ http://azxxx.vo.msecnd.net  3. Simple list of recent requests – showing where the request came from.   When you run the sample the first time you hit the page, both the Host and the CDN will cause 2 initial requests to hit the host.  You won’t see the first requests in the list because of timing – but if you refresh, you’ll see that the list will show that you have 2 requests initially. 1. sourced direct from the Browser to the HOST 2. sourced via the CDN The picture above shows the call-outs of each of those requests – green rows showing requests coming direct to the HOST, yellow showing the CDN request.  The IP addresses of the green items are direct from the client, where the CDN is from the CDN data center. As you refresh the page (hit Ctrl+F5 to force a full refresh and avoid “304 – not changed”) you’ll see that the request to the HOST get’s processed direct; but the request to the CDN endpoint is serviced direct from the CDN and doesn’t incur any additional request back to the HOST. The following is the Headers from the CDN response (Status-Line) HTTP/1.1 200 OK Age 13 Cache-Control public, max-age=300 Connection keep-alive Content-Length 6212 Content-Type image/jpeg; charset=utf-8 Date Fri, 11 Mar 2011 20:47:14 GMT Expires Fri, 11 Mar 2011 20:52:01 GMT Last-Modified Fri, 11 Mar 2011 20:47:02 GMT Server Microsoft-IIS/7.5 X-AspNet-Version 4.0.30319 X-Powered-By ASP.NET   The following are the Headers from the HOST response (Status-Line) HTTP/1.1 200 OK Cache-Control public, max-age=300 Content-Length 6189 Content-Type image/jpeg; charset=utf-8 Date Fri, 11 Mar 2011 20:47:15 GMT Last-Modified Fri, 11 Mar 2011 20:47:02 GMT Server Microsoft-IIS/7.5 X-AspNet-Version 4.0.30319 X-Powered-By ASP.NET   You can see that with the CDN request, the countdown (age) starts for aging the content. The full sample is located here: CDNSampleSite.zip [1] http://blogs.msdn.com/b/windowsazure/archive/2011/03/09/now-available-updated-windows-azure-sdk-and-windows-azure-management-portal.aspx [2] http://msdn.microsoft.com/en-us/library/ff919703.aspx

    Read the article

< Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >