  • Does the managed main UI thread stay on the same (unmanaged) Operation System thread?

    - by Daniel Rose
    I am creating a managed WPF UI front-end to a legacy Win32-application. The WPF front-end is the executable; as part of its startup routines I start the legacy app as a DLL in a second thread. Any UI-operation (including CreateWindowsEx, etc.) by the legacy app is invoked back on the main UI-thread. As part of the shutdown process of the app I want to clean up properly. Among other things, I want to call DestroyWindow on all unmanaged windows, so they can properly clean themselves up. Thus, during shutdown I use EnumWindows to try to find all my unmanaged windows. Then I call DestroyWindow one the list I generate. These run on the main UI-thread. After this background knowledge, on to my actual question: In the enumeration procedure of EnumWindows, I have to check if one of the returned top-level windows is one of my unmanaged windows. I do this by calling GetWindowThreadProcessId to get the process id and thread id of the window's creator. I can compare the process id with Process.GetCurrentProcess().Id to check if my app created it. For additional security, I also want to see if my main UI-thread created the window. However, the returned thread id is the OS's ThreadId (which is different than the managed thread id). As explained in this question, the CLR reserves the right to re-schedule the managed thread to different OS threads. Can I rely on the CLR to be "smart enough" to never do this for the main UI thread (due to thread-affinity of the UI)? Then I could call GetCurrentThreadId to get the main UI-thread's unmanaged thread id for comparison.

    Read the article

  • How do you send a named pipe string from umnanaged to managed code space?

    - by billmcf
    I appear to have a named pipes 101 issue. I have a very simple set up to connect a simplex named pipe transmitting from a C++ unmanaged app to a C# managed app. The pipe connects, but I cannot send a "message" through the pipe unless I close the handle which appears to flush the buffer and pass the message through. It's like the message is blocked. I have tried reversing the roles of client/server and invoking them with different Flag combinations without any luck. I can easily send messages in the other direction from C# managed to C++ unmanaged. Does anyone have any insight. Can any of you guys successfully send messages from C++ unmanaged to C# managed? I can find plenty of examples of intra amanged or unmanaged pipes but not inter managed to/from unamanged - just claims to be able to do it. In the listings, I have omitted much of the wrapper stuff for clarity. The key bits I believe that are relevant are the pipe connection/creation/read and write methods. Don't worry too much about blocking/threading here. C# Server side // This runs in its own thread and so it is OK to block private void ConnectToClient() { // This server will listen to the sending client if (m_InPipeStream == null) { m_InPipeStream = new NamedPipeServerStream("TestPipe", PipeDirection.In, 1); } // Wait for client to connect to our server m_InPipeStream.WaitForConnection(); // Verify client is running if (!m_InPipeStream.IsConnected) { return; } // Start listening for messages on the client stream if (m_InPipeStream != null && m_InPipeStream.CanRead) { ReadThread = new Thread(new ParameterizedThreadStart(Read)); ReadThread.Start(m_InPipeStream); } } // This runs in its own thread and so it is OK to block private void Read(object serverObj) { NamedPipeServerStream pipeStream = (NamedPipeServerStream)serverObj; using (StreamReader sr = new StreamReader(pipeStream)) { while (true) { string buffer = "" ; try { // Blocks here until the handle is closed by the client-side!! buffer = sr.ReadLine(); // <<<<<<<<<<<<<< Sticks here } catch { // Read error break; } // Client has disconnected? if (buffer == null || buffer.Length == 0) break; // Fire message received event if message is non-empty if (MessageReceived != null && buffer != "") { MessageReceived(buffer); } } } } C++ client side // Static - running in its own thread. DWORD CNamedPipe::ListenForServer(LPVOID arg) { // The calling app (this) is passed as the parameter CNamedPipe* app = (CNamedPipe*)arg; // Out-Pipe: connect as a client to a waiting server app->m_hOutPipeHandle = CreateFile("\\\\.\\pipe\\TestPipe", GENERIC_WRITE, 0, NULL, OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, NULL); // Could not create handle if (app->m_hInPipeHandle == NULL || app->m_hInPipeHandle == INVALID_HANDLE_VALUE) { return 1; } return 0; } // Sends a message to the server BOOL CNamedPipe::SendMessage(CString message) { DWORD dwSent; if (m_hOutPipeHandle == NULL || m_hOutPipeHandle == INVALID_HANDLE_VALUE) { return FALSE; } else { BOOL bOK = WriteFile(m_hOutPipeHandle, message, message.GetLength()+1, &dwSent, NULL); //FlushFileBuffers(m_hOutPipeHandle); // <<<<<<< Tried this return (!bOK || (message.GetLength()+1) != dwSent) ? FALSE : TRUE; } } // Somewhere in the Windows C++/MFC code... ... // This write is non-blocking. It just passes through having loaded the pipe. m_pNamedPipe->SendMessage("Hi de hi"); ...

    Read the article

  • How can I get popup window using commandButton in Trinidad?

    - by vikram
    How can I get popup window using commandButton in Trinidad? My problem is that by clicking on Add button from dialogdemo.jspx, not any popup window or dialog box is opened. This is dialogdemo.jspx file: <jsp:root xmlns:jsp="http://java.sun.com/JSP/Page" xmlns:f="http://java.sun.com/jsf/core" xmlns:tr="http://myfaces.apache.org/trinidad" version="1.2"> <jsp:directive.page contentType="text/html;charset=utf-8" /> <f:view> <tr:document title="Dialog Demo"> <tr:form> <!-- The field for the value; we point partialTriggers at the button to ensure it gets redrawn when we return --> <tr:inputText label="Pick a number:" partialTriggers="buttonId" value="#{launchDialog.input}" /> <!-- The button for launching the dialog: we've also configured the width and height of that window --> <tr:commandButton text="Add" action="dialog:chooseInteger" id="buttonId" windowWidth="300" windowHeight="200" partialSubmit="true" useWindow="true" returnListener="#{launchDialog.returned}" /> </tr:form> </tr:document> </f:view> </jsp:root> Here is the associated managed bean LaunchDialogBean.java: package jsfpkg; import org.apache.myfaces.trinidad.component.UIXInput; import org.apache.myfaces.trinidad.event.ReturnEvent; public class LaunchDialogBean { private UIXInput _input; public UIXInput getInput() { return _input; } public void setInput(UIXInput input) { _input = input; } public void returned(ReturnEvent event) { if (event.getReturnValue() != null) { getInput().setSubmittedValue(null); getInput().setValue(event.getReturnValue()); } } } Here is the popup file Popup.jspx: <jsp:root xmlns:jsp="http://java.sun.com/JSP/Page" xmlns:f="http://java.sun.com/jsf/core" xmlns:h="http://java.sun.com/jsf/html" xmlns:trh="http://myfaces.apache.org/trinidad/html" xmlns:tr="http://myfaces.apache.org/trinidad" version="2.0"> <jsp:directive.page contentType="text/html;charset=utf-8" /> <f:view> <tr:document title="Add dialog"> <tr:form> <!-- Two input fields --> <tr:panelForm> <tr:inputText label="Number 1:" value="#{chooseInteger.value1}" required="true" /> <tr:inputText label="Number 2:" value="#{chooseInteger.value2}" required="true" /> </tr:panelForm> <!-- Two buttons --> <tr:panelGroup layout="horizontal"> <tr:commandButton text="Submit" action="#{chooseInteger.select}" /> <tr:commandButton text="Cancel" immediate="true" action="#{chooseInteger.cancel}" /> </tr:panelGroup> </tr:form> </tr:document> </f:view> </jsp:root> For that I have written the bean ChooseIntegerBean.java package jsfpkg; import org.apache.myfaces.trinidad.context.RequestContext; public class ChooseIntegerBean { private Integer _value1; private Integer _value2; public Integer getValue1() { return _value1; } public void setValue1(Integer value1) { _value1 = value1; } public Integer getValue2() { return _value2; } public void setValue2(Integer value2) { _value2 = value2; } public String cancel() { RequestContext.getCurrentInstance().returnFromDialog(null, null); return null; } public String select() { Integer value = new Integer(getValue1().intValue() + getValue2().intValue()); RequestContext.getCurrentInstance().returnFromDialog(value, null); return null; } } Here is my faces-config.xml: <managed-bean> <managed-bean-name>chooseInteger</managed-bean-name> <managed-bean-class>jsfpkg.ChooseIntegerBean</managed-bean-class> <managed-bean-scope>request</managed-bean-scope> </managed-bean> <managed-bean> <managed-bean-name>launchDialog</managed-bean-name> <managed-bean-class>jsfpkg.LaunchDialogBean</managed-bean-class> <managed-bean-scope> request </managed-bean-scope> </managed-bean> <navigation-rule> <from-view-id>/dialogdemo.jspx</from-view-id> <navigation-case> <from-outcome>dialog:chooseInteger</from-outcome> <to-view-id>/dialogbox.jspx</to-view-id> </navigation-case> </navigation-rule>

    Read the article

  • If a managed network switch were to overheat, would you consider it no longer reliable?

    - by Scott Szretter
    Here is the scenario - I have a network switch, one of several in a stack. It's fan failed. Soon, there were reports of users with network issues. After quickly replacing the fan, the users were fine, network issues were resolved. I assume the unit was overheating, and thus failing somehow. Today someone suggested to me, that I should not assume the unit is 100% reliable anymore. So what do you think, would an overheat condition (less than 1 day with the fan stopped) potentially cause permanent damage that could at some point come to the surface as future network failures/issues? If it matters, we are talking managed switches such as 3Com/HP SuperStack , ProCurve or PWR-Plus.

    Read the article

  • How do I use long names to refer to Group Managed Service Accounts (gMSA)?

    - by Jason Stangroome
    Commonly domain user accounts are used as service accounts. With domain user accounts, the username can easily be as long as 64 characters as long as the User Principal Name (UPN) is used to refer to the account, eg [email protected]. If you still use the legacy pre-Windows 2000 names (SAM) you have to truncate it to ~20 characters, eg mydomain\truncname. When using the New-ADServiceAccount PowerShell cmdlet to create a new Group Managed Service Account (gMSA) and a name longer than 15 characters is specified, an error is returned. To specify a longer name, the SAM name must be specified separately, eg: New-ADServiceAccount -Name longname -SamAccountName truncname ... To configure a service to run as the new gMSA, I can use the legacy username format mydomain\truncname$ but using usernames with a maximum of 15 characters in 2013 is a smell. How do I refer to a gMSA using the UPN-style format instead? I tried the longname$@domainfqdn approach but that didn't work. It also seems that the gMSA object in AD doesn't have a userPrincipalName attribute value specified.

    Read the article

  • does the *physical* order/location of drives in a mdadm-managed RAID-10 array matter?

    - by locuse
    i've setup a 4-drive RAID-10 array using mdadm-managed, software-raid on an x86_64 box. it'd up & running and works as expected, cat /proc/mdstat md127 : active raid10 sdc2[2] sdd2[3] sda2[0] sdb2[1] 1951397888 blocks super 1.2 512K chunks 2 far-copies [4/4] [UUUU] bitmap: 9/466 pages [36KB], 2048KB chunk atm the four SATA drives are physically plugged into the motherboard's 1st four SATA ports. i'd like to gather the necessary/complete info for catastrophic recovery. reading starting here, http://neil.brown.name/blog, and the mailing list, i'm not yet completely confident i have it right. i understand 'drive order matters'. is that logical, &/or physical order that matters? if i unplugged the four drives in this array, and plugged them each back into different ports on the motherboard or a pci card, as long as i've changed nothing in software config, will the array correctly auto-re-assemble?

    Read the article

  • How Unicode strings can be passed from a managed to an unmanaged function...

    - by Who Cares
    I will really appreciate anybody's help about how a Unicode string can be passed (marshaled) from a managed (Delphi .NET) to an unmanaged (Delphi's Win32 DLL) function. The managed environment (Delphi .NET): ... interface ... const TM_PRO_CONVERTER = 'TM.PROFileConverter.dll'; function ImportLineworksFromPROFile(FileName :String; TargetFileNameDXF :String): Integer; ... implementation ... [DllImport(TM_PRO_CONVERTER, EntryPoint = 'ImportLineworksFromPROFile', CharSet = CharSet.Ansi, SetLastError = True, CallingConvention = CallingConvention.StdCall)] function ImportLineworksFromPROFile(FileName :String; TargetFileNameDXF :String): Integer; external; ... The unmanaged environment (Delphi's Win32 DLL): library TM.PROFileConverter; ... function ImportLineworksFromPROFile(FileName :String; TargetFileNameDXF :String) :Integer; stdcall; exports ImportLineworksFromPROFile; ... Thank you for your time.

    Read the article

  • How to debug unreleased COM references from managed code?

    - by Marek
    I have been searching for a tool to debug unreleased COM references, that usually cause e.g. Word/Outlook processes to hang in memory in case the code does not call Marshal.ReleaseCOMObject on all COM instances correctly. (Outlook 2007 partially fixes this for outlook addins, but this is a generic question). Is there a tool that would display at least a list of COM references (by type) held by managed code? Ideally, it would also display memory profiler-style object trees helping to debug where the reference increment occured. Debugging at runtime is not that important as being able to attach to a hung process - because the problem typically occurs when the code is done with the COM interface and someone forgot to release something - the application (e.g. winword) hangs in memory even after the calling managed application quits. If such tool does not exist, what is the (technical?) reason? It would be very useful for debugging a lot of otherwise very hard to find problems when working with COM interop.

    Read the article

  • Has anybody managed to teach themself strong OOP skills through mainly developing with JavaScript?

    - by yaya3
    I am trying to do this, I'm a full time front-end dev and am aware that I am struglling to achieve this. When I am referring to OOP skills I am referring to understanding and being familiar with concepts like inheritance, polymorphism, encapsulation, abstaction. I am aware that it may be more likely to achieve what I'm after by focusing on another language in my spare time. This is the plan, but I'd be really intrigued to hear if anybody has managed to achieve this purely through JavaScript and how you did it. It'd be even better to hear from strong OOP developers from who use different programming languages to know if they have worked with developers who have managed to achieve this.

    Read the article

  • How to terminate a managed thread blocked in unmanaged code?

    - by James Curran
    I have a managed thread which is waiting, blocked, in an unmanaged code (specifically, it on a call to NamedPipeServerStream.WaitForConnection() which ultimitely calls into unmanaged code, and does not offer a timeout). I want to shut the thread down neatly. Thread.Abort() has no effect until the code returns to the managed realm, which it won't do until a client makes a connection, which we can't wait for). I need a way "shock" it out of the unmanaged code; or a way to just kill the thread even while it's in unmanaged land.

    Read the article

  • How-to remove the close icon from task flows opened in dialogs (11.1.1.4)

    - by frank.nimphius
    Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} ADF bounded task flows can be opened in an external dialog and return values to the calling application as documented in chapter 19 of Oracle Fusion Middleware Fusion Developer's Guide for Oracle Application Development Framework11g: http://download.oracle.com/docs/cd/E17904_01/web.1111/b31974/taskflows_dialogs.htm#BABBAFJB   Setting the task flow call activity property Run as Dialog to true and the Display Type property to inline-popup opens the bounded task flow in an inline popup. To launch the dialog, a command item is used that references the control flow case to the task flow call activity <af:commandButton text="Lookup" id="cb6"         windowEmbedStyle="inlineDocument" useWindow="true"         windowHeight="300" windowWidth="300"         action="lookup" partialSubmit="true"/> By default, the dialog opens with a close icon in its header that does not raise a task flow return event when used for dismissing the dialog. In previous releases, the close icon could only be hidden using CSS in a custom skin definition, as explained in a previous OTN Harvest publishing (12/2010) http://www.oracle.com/technetwork/developer-tools/adf/learnmore/dec2010-otn-harvest-199274.pdf As a new feature, Oracle JDeveloper 11g (11.1.1.4) provides an option to globally remove the close icon from inline dialogs without using CSS. For this, the following managed bean definition needs to be added to the adfc-config.xml file. <managed-bean>   <managed-bean-name>     oracle$adfinternal$view$rich$dailogInlineDocument   </managed-bean-name>   <managed-bean-class>java.util.TreeMap</managed-bean-class>   <managed-bean-scope>application</managed-bean-scope>     <map-entries>       <key-class>java.lang.String</key-class>       <value-class>java.lang.String</value-class>       <map-entry>         <key>MODE</key>         <value>withoutCancel</value>       </map-entry>     </map-entries>   </managed-bean> Note the setting of the managed bean scope to be application which applies this setting to all sessions of an application.

    Read the article

  • What are my options in replacing the noisy fan in my Linksys Cisco SRW2008P managed GigE switch?

    - by Fred Sobotka
    My first managed GigE switch, the Linksys SRW2008, was a dream, until it started randomly chattering on various ports. That started while I was on the road all the time, which made it take forever to diagnose, but that's a different problem. When I finally determined that the switch was bad, it was still covered by warranty by Linksys/Cisco, so I opened an RMA ticket and returned it. Unfortunately, Linksys/Cisco "upgraded" my replacement switch to a SRW2008P, which has Power over Ethernet features I never planned on using. That by itself wasn't so bad, but it's my guess that the inclusion of PoE functions in this model required a tiny, super-loud internal fan to keep everything cool. This wasn't something I wanted or asked for, but, now that I am stuck with it, I am investigating options for replacing that little internal fan with something far quieter. For example, if I attach a larger fan to the outsite of the chassis, I think it could push enough air to replace the stock fan that is currently there. Any advice on carrying this out? I have no interest in melting my switch due to insufficient ventilation.

    Read the article

  • C#. How to pass message from unsafe callback to managed code?

    - by maxima120
    Is there a simple example of how to pass messages from unsafe callback to managed code? I have a proprietary dll which receives some messages packed in structs and all is coming to a callback function. The example of usage is as follows but it calls unsafe code too. I want to pass the messages into my application which is all managed code. *P.S. I have no experience in interop or unsafe code. I used to develop in C++ 8 yrs ago but remember very little from that nightmarish times :) P.P.S. The application is loaded as hell, the original devs claim it processes 2mil messages per sec.. I need a most efficient solution.* static unsafe int OnCoreCallback(IntPtr pSys, IntPtr pMsg) { // Alias structure pointers to the pointers passed in. CoreSystem* pCoreSys = (CoreSystem*)pSys; CoreMessage* pCoreMsg = (CoreMessage*)pMsg; // message handler function. if (pCoreMsg->MessageType == Core.MSG_STATUS) OnCoreStatus(pCoreSys, pCoreMsg); // Continue running return (int)Core.CALLBACKRETURN_CONTINUE; } Thank you.

    Read the article

  • Port forwarding in C#/software possible? Isn't it only managed by the router?

    - by Rudi
    Isn't port forwarding managed by the router? Like, I've googled up some software applications that seem to port forward with great success, but it technically seems to be impossible. The packet must first go to the router. The router must forward it to the correct computer based on port forwarding rules. So how can a software application manage port forwarding if the packet must GO to the computer running this software application in the first place, meaning that port forwarding already is successful in the first place?

    Read the article

  • how do i load an image from a DB inside a jsf using managed beans?

    - by RhigoHR
    Hi.. i have a database with some images...could anyone tell me or explain me how could i can load an image in a jsf? I alredy have a managed bean that converts an Image object into a streamcontent...and this streamcontent is called from the page in a tag , but when a i check the source code of the page, there's no src where the image could be loaded. Hope an answer, thx

    Read the article

  • Can two managed object context share one single persistent store coordinator?

    - by mystify
    Example: I have one persistent store coordinator which uses one single persistent store. Now there are two managed object contexts, and both want to use the same persistent store. Could both simply use the same persistent store coordinator, or would I have to create two instances of NSPersistentStoreCoordinator? And if I had to, then: Would I also have to create two NSPersistentStore instances?

    Read the article

  • How can i Import a Managed C# dll into a Win32 C++ project ?

    - by Agito
    I am working on a solution, most of its core engine is developed as Win32 C++ (and is Platform independent and is also used on OS X), some time ago we needed to call C++ dll's of core engine from C# and I was able to Load main solution's DLL in C# (by the help of some threads here on SO). but now we have certain things implemented in Managed C# dll and need to use it in Win32 C++ project? (and just function definitions and dll are provided)

    Read the article

  • WIX/DTF - How do I elevate deffered managed custom actions?

    - by Jarrod
    We are working on creating an installer using WIX. We have a couple of custom actions that are going to require elevation to run on Vista. Our MSI obviously elevates itself, because I get a UAC prompt and it writes keys to HKLM. Our managed DTF custom actions are apparently not running elevated. If I start the MSI from an elevated command prompt, the installation runs fine. The only workaround I have seen suggested (link) is to use another exe with a manifest as a bootstrapper to run the MSI. This is not a good solution, as it doesn't allow the user to modify the installation by selecting "Change" from the Add/Remove programs dialog. Our install has multiple features that can be customized, so we want this functionality. Does anybody know how to do this?

    Read the article