Search Results

Search found 21518 results on 861 pages for 'multi query'.

Page 13/861 | < Previous Page | 9 10 11 12 13 14 15 16 17 18 19 20  | Next Page >

  • SQL SERVER – Simple Demo of New Cardinality Estimation Features of SQL Server 2014

    - by Pinal Dave
    SQL Server 2014 has new cardinality estimation logic/algorithm. The cardinality estimation logic is responsible for quality of query plans and majorly responsible for improving performance for any query. This logic was not updated for quite a while, but in the latest version of SQL Server 2104 this logic is re-designed. The new logic now incorporates various assumptions and algorithms of OLTP and warehousing workload. Cardinality estimates are a prediction of the number of rows in the query result. The query optimizer uses these estimates to choose a plan for executing the query. The quality of the query plan has a direct impact on improving query performance. ~ Souce MSDN Let us see a quick example of how cardinality improves performance for a query. I will be using the AdventureWorks database for my example. Before we start with this demonstration, remember that even though you have SQL Server 2014 to see the effect of new cardinality estimates, you will need your database compatibility mode set to 120 which is for SQL Server 2014. If your server instance of SQL Server 2014 but you have set up your database compatibility mode to 110 or any other earlier version, you will get performance from your query like older version of SQL Server. Now we will execute following query in two different compatibility mode and see its performance. (Note that my SQL Server instance is of version 2014). USE AdventureWorks2014 GO -- ------------------------------- -- NEW Cardinality Estimation ALTER DATABASE AdventureWorks2014 SET COMPATIBILITY_LEVEL = 120 GO EXEC [dbo].[uspGetManagerEmployees] 44 GO -- ------------------------------- -- Old Cardinality Estimation ALTER DATABASE AdventureWorks2014 SET COMPATIBILITY_LEVEL = 110 GO EXEC [dbo].[uspGetManagerEmployees] 44 GO Result of Statistics IO Compatibility level 120 Table ‘Person’. Scan count 0, logical reads 6, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Employee’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Worktable’. Scan count 0, logical reads 0, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Worktable’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Compatibility level 110 Table ‘Worktable’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Person’. Scan count 0, logical reads 137, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Employee’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Worktable’. Scan count 0, logical reads 0, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. You will notice in the case of compatibility level 110 there 137 logical read from table person where as in the case of compatibility level 120 there are only 6 physical reads from table person. This drastically improves the performance of the query. If we enable execution plan, we can see the same as well. I hope you will find this quick example helpful. You can read more about this in my latest Pluralsight Course. Reference: Pinal Dave (http://blog.SQLAuthority.com)Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL

    Read the article

  • 5 Lessons learnt in localization / multi language support in WPF

    - by MarkPearl
    For the last few months I have been secretly working away at the second version of an application that we initially released a few years ago. It’s called MaxCut and it is a free panel/cut optimizer for the woodwork, glass and metal industry. One of the motivations for writing MaxCut was to get an end to end experience in developing an application for general consumption. From the early days of v1 of MaxCut I would get the odd email thanking me for the software and then listing a few suggestions on how to improve it. Two of the most dominant suggestions that we received were… Support for imperial measurements (the original program only supported the metric system) Multi language support (we had someone who volunteered to translate the program into Japanese for us). I am not going to dive into the Imperial to Metric support in todays blog post, but I would like to cover a few brief lessons we learned in adding support for multi-language functionality in the software. I have sectioned them below under different lessons. Lesson 1 – Build multi-language support in from the start So the first lesson I learnt was if you know you are going to do multi language support – build it in from the very beginning! One of the power points of WPF/Silverlight is data binding in XAML and so while it wasn’t to painful to retro fit multi language support into the programing, it was still time consuming and a bit tedious to go through mounds and mounds of views and would have been a minor job to have implemented this while the form was being designed. Lesson 2 – Accommodate for varying word lengths using Grids The next lesson was a little harder to learn and was learnt a bit further down the road in the development cycle. We developed everything in English, assuming that other languages would have similar character length words for equivalent meanings… don’t!. A word that is short in your language may be of varying character lengths in other languages. Some language like Dutch and German allow for concatenation of nouns which has the potential to create really long words. We picked up a few places where our views had been structured incorrectly so that if a word was to long it would get clipped off or cut out. To get around this we began using the WPF grid extensively with column widths that would automatically expand if they needed to. Generally speaking the grid replacement got round this hurdle, and if in future you have a choice between a stack panel or a grid – think twice before going for the easier option… often the grid will be a bit more work to setup, but will be more flexible. Lesson 3 – Separate the separators Our initial run through moving the words to a resource dictionary led us to make what I thought was one potential mistake. If we had a label like the following… “length : “ In the resource dictionary we put it as a single entry. This is fine until you start using a word more than once. For instance in our scenario we used the word “length’ frequently. with different variations of the word with grammar and separators included in the resource we ended up having what I would consider a bloated dictionary. When we removed the separators from the words and put them as their own resources we saw a dramatic reduction in dictionary size… so something that looked like this… “length : “ “length. “ “length?” Was reduced to… “length” “:” “?” “.” While this may not seem like a reduction at first glance, consider that the separators “:?.” are used everywhere and suddenly you see a real reduction in bloat. Lesson 4 – Centralize the Language Dictionary This lesson was learnt at the very end of the project after we had already had a release candidate out in the wild. Because our translations would be done on a volunteer basis and remotely, we wanted it to be really simple for someone to translate our program into another language. As a common design practice we had tiered the application so that we had a business logic layer, a ui layer, etc. The problem was in several of these layers we had resource files specific for that layer. What this resulted in was us having multiple resource files that we would need to send to our translators. To add to our problems, some of the wordings were duplicated in different resource files, which would result in additional frustration from our translators as they felt they were duplicating work. Eventually the workaround was to make a separate project in VS2010 with just the language translations. We then exposed the dictionary as public within this project and made it as a reference to the other projects within the solution. This solved out problem as now we had a central dictionary and could remove any duplication's. Lesson 5 – Make a dummy translation file to test that you haven’t missed anything The final lesson learnt about multi language support in WPF was when checking if you had forgotten to translate anything in the inline code, make a test resource file with dummy data. Ideally you want the data for each word to be identical. In our instance we made one which had all the resource key values pointing to a value of test. This allowed us point the language file to our test resource file and very quickly browse through the program and see if we had missed any linking. The alternative to this approach is to have two language files and swap between the two while running the program to make sure that you haven’t missed anything, but the downside of dual language file approach is that it is much a lot harder spotting a mistake if everything is different – almost like playing Where’s Wally / Waldo. It is much easier spotting variance in uniformity – meaning when you put the “test’ keyword for everything, anything that didn’t say “test” stuck out like a sore thumb. So these are my top five lessons learnt on implementing multi language support in WPF. Feel free to make any suggestions in the comments section if you feel maybe something is more important than one of these or if I got it wrong!

    Read the article

  • Is there any multi-touch graphics tablet with Linux drivers?

    - by Zifre
    After watching the absolutely amazing 10/GUI video, I have been dying to try to implement something like this. I can do the software side quite easily, but I don't have the hardware. The Wacom Bamboo Fun would work, but the Linux drivers don't support the multi-touch features. Microsoft's "UnMouse Pad" looks like the perfect solution, but it is not commercially available yet. Are there any similar devices that would work? Alternatively, is there a way to build a DIY version? (It is fairly easy to build a multi-touch display with a webcam and IR LEDs, but it would not be pressure sensitive. Does anyone have any info on how the UnMouse Pad works and if it is possible to build one?) EDIT: I should clarify that I don't want a multi-touch display. I want the sensor to be separate from the display. If that sounds crazy, watch the 10/GUI video.

    Read the article

  • SQL SERVER – DMV – sys.dm_os_waiting_tasks and sys.dm_exec_requests – Wait Type – Day 4 of 28

    - by pinaldave
    Previously, we covered the DMV sys.dm_os_wait_stats, and also saw how it can be useful to identify the major resource bottleneck. However, at the same time, we discussed that this is only useful when we are looking at an instance-level picture. Quite often we want to know about the processes going in our server at the given instant. Here is the query for the same. This DMV is written taking the following into consideration: we want to analyze the queries that are currently running or which have recently ran and their plan is still in the cache. SELECT dm_ws.wait_duration_ms, dm_ws.wait_type, dm_es.status, dm_t.TEXT, dm_qp.query_plan, dm_ws.session_ID, dm_es.cpu_time, dm_es.memory_usage, dm_es.logical_reads, dm_es.total_elapsed_time, dm_es.program_name, DB_NAME(dm_r.database_id) DatabaseName, -- Optional columns dm_ws.blocking_session_id, dm_r.wait_resource, dm_es.login_name, dm_r.command, dm_r.last_wait_type FROM sys.dm_os_waiting_tasks dm_ws INNER JOIN sys.dm_exec_requests dm_r ON dm_ws.session_id = dm_r.session_id INNER JOIN sys.dm_exec_sessions dm_es ON dm_es.session_id = dm_r.session_id CROSS APPLY sys.dm_exec_sql_text (dm_r.sql_handle) dm_t CROSS APPLY sys.dm_exec_query_plan (dm_r.plan_handle) dm_qp WHERE dm_es.is_user_process = 1 GO You can change CROSS APPLY to OUTER APPLY if you want to see all the details which are omitted because of the plan cache. Let us analyze the result of the above query and see how it can be helpful to identify the query and the kind of wait type it creates. Click to Enlarage The above query will return various columns. There are various columns that provide very important details. e.g. wait_duration_ms – it indicates current wait for the query that executes at that point of time. wait_type – it indicates the current wait type for the query text – indicates the query text query_plan – when clicked on the same, it will display the query plans There are many other important information like CPU_time, memory_usage, and logical_reads, which can be read from the query as well. In future posts on this series, we will see how once identified wait type we can attempt to reduce the same. Read all the post in the Wait Types and Queue series. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: DMV, Pinal Dave, PostADay, SQL, SQL Authority, SQL DMV, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQL Wait Stats, SQL Wait Types, T SQL, Technology

    Read the article

  • SQL SERVER – Quiz and Video – Introduction to Discovering XML Data Type Methods

    - by pinaldave
    This blog post is inspired from SQL Interoperability Joes 2 Pros: A Guide to Integrating SQL Server with XML, C#, and PowerShell – SQL Exam Prep Series 70-433 – Volume 5. [Amazon] | [Flipkart] | [Kindle] | [IndiaPlaza] This is follow up blog post of my earlier blog post on the same subject - SQL SERVER – Introduction to Discovering XML Data Type Methods – A Primer. In the article we discussed various basics terminology of the XML. The article further covers following important concepts of XML. What are XML Data Type Methods The query() Method The value() Method The exist() Method The modify() Method Above five are the most important concepts related to XML and SQL Server. There are many more things one has to learn but without beginners fundamentals one can’t learn the advanced  concepts. Let us have small quiz and check how many of you get the fundamentals right. Quiz 1.) Which method returns an XML fragment from the source XML? query( ) value( ) exist( ) modify( ) All of them Only query( ) and value( ) 2.) Which XML data type method returns a “1” if found and “0” if the specified XPath is not found in the source XML? query( ) value( ) exist( ) modify( ) All of them Only query( ) and value( ) 3.) Which XML data type method allows you to pick the data type of the value that is returned from the source XML? query( ) value( ) exist( ) modify( ) All of them Only query( ) and value( ) 4.) Which method will not work with a SQL SELECT statement? query( ) value( ) exist( ) modify( ) All of them Only query( ) and value( ) Now make sure that you write down all the answers on the piece of paper. Watch following video and read earlier article over here. If you want to change the answer you still have chance. Solution 1) 1 2) 3 3) 2 4) 4 Now compare let us check the answers and compare your answers to following answers. I am very confident you will get them correct. Available at USA: Amazon India: Flipkart | IndiaPlaza Volume: 1, 2, 3, 4, 5 Please leave your feedback in the comment area for the quiz and video. Did you know all the answers of the quiz? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Joes 2 Pros, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • What web hosts support multi-domain SSL?

    - by Bryan Hadaway
    For Consideration - Please do not close or refer this question to: How to find web hosting that meets my requirements? The above link does not refer to SSL certificates in any manner. This question has a very specific objective of listing known web hosts that support this new SSL technology. If I'm not mistaken, multi-domain (not wildcard) SSL is a relatively new technology that is not hugely supported or well-known/advertised yet? I'm having a difficult time discovering which web hosts support the technology (again because it's not popular enough yet to advertise on feature lists). Here is what I've discovered so far: Web Hosts That DO NOT Support Multi-domain SSL BlueHost/HostMonster DreamHost Web Hosts That DO Support Multi-domain SSL FireHost HostGator Please note that SUPPORT doesn't necessarily mean they offer the SSL certs themselves and you may need to purchase separately.

    Read the article

  • Will removing unused query string parameters negatively affect SEO?

    - by trm
    Will changing links to remove query string parameters that are no longer used have any negative impact on search engine rankings? Say I have a page about.php on my site, and all of my links to this page are of the form http://www.example.com/about.php?foo=bar and I've made some changes to the script such that the parameter foo is no longer used. I would like to remove the unused parameter from the links so the URL will look cleaner, but I am concerned that this could cause problems with SEO. Is it safe to remove ?foo=bar from my links?

    Read the article

  • Linq-to-sql Compiled Query returning object NOT belonging to submitted DataContext

    - by Vladimir Kojic
    Compiled query: public static class Machines { public static readonly Func<OperationalDataContext, short, Machine> QueryMachineById = CompiledQuery.Compile((OperationalDataContext db, short machineID) => db.Machines.Where(m => m.MachineID == machineID).SingleOrDefault() ); public static Machine GetMachineById(IUnitOfWork unitOfWork, short id) { Machine machine; // Old code (working) //var machineRepository = unitOfWork.GetRepository<Machine>(); //machine = machineRepository.Find(m => m.MachineID == id).SingleOrDefault(); // New code (making problems) machine = QueryMachineById(unitOfWork.DataContext, id); return machine; } It looks like compiled query is caching Machine object and returning the same object even if query is called from new DataContext (I’m disposing DataContext in the service but I’m getting Machine from previous DataContext). I use POCOs and XML mapping. Revised: It looks like compiled query is returning result from new data context and it is not using the one that I passed in compiled-query. Therefore I can not reuse returned object and link it to another object obtained from datacontext thru non compiled queries. [TestMethod] public void GetMachinesTest() { // Test Preparation (not important) using (var unitOfWork = IoC.Get<IUnitOfWork>()) { var machineRepository = unitOfWork.GetRepository<Machine>(); // GET ALL List<Machine> list = machineRepository.FindAll().ToList<Machine>(); VerifyIntegratedMachine(list[2], 3, "Machine 3", "333333", "G300PET", "MachineIconC.xaml", false, true, LicenseType.Licensed, "10.0.97.3", "10.0.97.3", 0); var machine = Machines.GetMachineById(unitOfWork, 3); Assert.AreSame(list[2], machine); // PASS !!!! } using (var unitOfWork = IoC.Get<IUnitOfWork>()) { var machineRepository = unitOfWork.GetRepository<Machine>(); // GET ALL List<Machine> list = machineRepository.FindAll().ToList<Machine>(); VerifyIntegratedMachine(list[2], 3, "Machine 3", "333333", "G300PET", "MachineIconC.xaml", false, true, LicenseType.Licensed, "10.0.97.3", "10.0.97.3", 0); var machine = Machines.GetMachineById(unitOfWork, 3); Assert.AreSame(list[2], machine); // FAIL !!!! } } If I run other (complex) unit tests I'm getting as expected: An attempt has been made to Attach or Add an entity that is not new, perhaps having been loaded from another DataContext.

    Read the article

  • solr JOIN query

    - by Sfairas
    I need to run a JOIN query on a solr index. I've got two xmls that I have indexed, person.xml and subject.xml. Person: <doc> <field name="id">P39126</field> <field name="family">Smith</field> <field name="given">John</field> <field name="subject">S1276</field> <field name="subject">S1312</field> </doc> Subject: <doc> <field name="id">S1276</field> <field name="topic">Abnormalities, Human</field> </doc> I need to only display information from the person doc but each query should match fields in both person and subject. In the case the query matches only the subject doc I need to display all docs from the person that have a matching id. Is this possible to do without running two seperate queries? Something like a JOIN query would do the job. Any help?

    Read the article

  • CUDA: Memory copy to GPU 1 is slower in multi-GPU

    - by zenna
    My company has a setup of two GTX 295, so a total of 4 GPUs in a server, and we have several servers. We GPU 1 specifically was slow, in comparison to GPU 0, 2 and 3 so I wrote a little speed test to help find the cause of the problem. //#include <stdio.h> //#include <stdlib.h> //#include <cuda_runtime.h> #include <iostream> #include <fstream> #include <sstream> #include <string> #include <cutil.h> __global__ void test_kernel(float *d_data) { int tid = blockDim.x*blockIdx.x + threadIdx.x; for (int i=0;i<10000;++i) { d_data[tid] = float(i*2.2); d_data[tid] += 3.3; } } int main(int argc, char* argv[]) { int deviceCount; cudaGetDeviceCount(&deviceCount); int device = 0; //SELECT GPU HERE cudaSetDevice(device); cudaEvent_t start, stop; unsigned int num_vals = 200000000; float *h_data = new float[num_vals]; for (int i=0;i<num_vals;++i) { h_data[i] = float(i); } float *d_data = NULL; float malloc_timer; cudaEventCreate(&start); cudaEventCreate(&stop); cudaEventRecord( start, 0 ); cudaMemcpy(d_data, h_data, sizeof(float)*num_vals,cudaMemcpyHostToDevice); cudaMalloc((void**)&d_data, sizeof(float)*num_vals); cudaEventRecord( stop, 0 ); cudaEventSynchronize( stop ); cudaEventElapsedTime( &malloc_timer, start, stop ); cudaEventDestroy( start ); cudaEventDestroy( stop ); float mem_timer; cudaEventCreate(&start); cudaEventCreate(&stop); cudaEventRecord( start, 0 ); cudaMemcpy(d_data, h_data, sizeof(float)*num_vals,cudaMemcpyHostToDevice); cudaEventRecord( stop, 0 ); cudaEventSynchronize( stop ); cudaEventElapsedTime( &mem_timer, start, stop ); cudaEventDestroy( start ); cudaEventDestroy( stop ); float kernel_timer; cudaEventCreate(&start); cudaEventCreate(&stop); cudaEventRecord( start, 0 ); test_kernel<<<1000,256>>>(d_data); cudaEventRecord( stop, 0 ); cudaEventSynchronize( stop ); cudaEventElapsedTime( &kernel_timer, start, stop ); cudaEventDestroy( start ); cudaEventDestroy( stop ); printf("cudaMalloc took %f ms\n",malloc_timer); printf("Copy to the GPU took %f ms\n",mem_timer); printf("Test Kernel took %f ms\n",kernel_timer); cudaMemcpy(h_data,d_data, sizeof(float)*num_vals,cudaMemcpyDeviceToHost); delete[] h_data; return 0; } The results are GPU0 cudaMalloc took 0.908640 ms Copy to the GPU took 296.058777 ms Test Kernel took 326.721283 ms GPU1 cudaMalloc took 0.913568 ms Copy to the GPU took[b] 663.182251 ms[/b] Test Kernel took 326.710785 ms GPU2 cudaMalloc took 0.925600 ms Copy to the GPU took 296.915039 ms Test Kernel took 327.127930 ms GPU3 cudaMalloc took 0.920416 ms Copy to the GPU took 296.968384 ms Test Kernel took 327.038696 ms As you can see, the cudaMemcpy to the GPU is well double the amount of time for GPU1. This is consistent between all our servers, it is always GPU1 that is slow. Any ideas why this may be? All servers are running windows XP.

    Read the article

  • Prevent full table scan for query with multiple where clauses

    - by Dave Jarvis
    A while ago I posted a message about optimizing a query in MySQL. I have since ported the data and query to PostgreSQL, but now PostgreSQL has the same problem. The solution in MySQL was to force the optimizer to not optimize using STRAIGHT_JOIN. PostgreSQL offers no such option. Here is the explain: Here is the query: SELECT avg(d.amount) AS amount, y.year FROM station s, station_district sd, year_ref y, month_ref m, daily d LEFT JOIN city c ON c.id = 10663 WHERE -- Find all the stations within a specific unit radius ... -- 6371.009 * SQRT( POW(RADIANS(c.latitude_decimal - s.latitude_decimal), 2) + (COS(RADIANS(c.latitude_decimal + s.latitude_decimal) / 2) * POW(RADIANS(c.longitude_decimal - s.longitude_decimal), 2)) ) <= 50 AND -- Ignore stations outside the given elevations -- s.elevation BETWEEN 0 AND 2000 AND sd.id = s.station_district_id AND -- Gather all known years for that station ... -- y.station_district_id = sd.id AND -- The data before 1900 is shaky; insufficient after 2009. -- y.year BETWEEN 1980 AND 2000 AND -- Filtered by all known months ... -- m.year_ref_id = y.id AND m.month = 12 AND -- Whittled down by category ... -- m.category_id = '001' AND -- Into the valid daily climate data. -- m.id = d.month_ref_id AND d.daily_flag_id <> 'M' GROUP BY y.year It appears as though PostgreSQL is looking at the DAILY table first, which is simply not the right way to go about this query as there are nearly 300 million rows. How do I force PostgreSQL to start at the CITY table? Thank you!

    Read the article

  • Out of memory with multi images in one picturebox

    - by Nikom
    Hi, ive problem with out of memory when im trying load few images into one picturebox. Pls Help :) public void button2_Click(object sender, EventArgs e) { FolderBrowserDialog dialog = new FolderBrowserDialog(); dialog.ShowDialog(); string selected = dialog.SelectedPath; string[] imageFileList = Directory.GetFiles(selected); int iCtr = 0,zCtr = 0; foreach(string imageFile in imageFileList) { if (Image.FromFile(imageFile) != null) { Image.FromFile(imageFile).Dispose(); } PictureBox eachPictureBox = new PictureBox(); eachPictureBox.Size = new Size(100,100); // if (iCtr % 8 == 0) //{ // zCtr++; // iCtr = 0; //} eachPictureBox.Location = new Point(iCtr * 100 + 1, 1); eachPictureBox.Image = Image.FromFile(imageFile); iCtr++; panel1.Controls.Add(eachPictureBox); } }`enter code here`

    Read the article

  • Increase Query Speed in PostgreSQL

    - by Anthoni Gardner
    Hello, First time posting here, but an avid reader. I am experiancing slow query times on my database (all tested locally thus far) and not sure how to go about it. The database itself has 44 tables and some of them tables have over 1 Million records (mainly the movies, actresses and actors tables). The table is made via JMDB using the flat files on IMDB. Also the SQL query that I am about to show is from that said program (that too experiances very slow search times). I have tried to include as much information as I can, such as the explain plan etc. "QUERY PLAN" "HashAggregate (cost=46492.52..46493.50 rows=98 width=46)" " Output: public.movies.title, public.movies.movieid, public.movies.year" " - Append (cost=39094.17..46491.79 rows=98 width=46)" " - HashAggregate (cost=39094.17..39094.87 rows=70 width=46)" " Output: public.movies.title, public.movies.movieid, public.movies.year" " - Seq Scan on movies (cost=0.00..39093.65 rows=70 width=46)" " Output: public.movies.title, public.movies.movieid, public.movies.year" " Filter: (((title)::text ~~* '%Babe%'::text) AND ((title)::text !~~* '""%}'::text))" " - Nested Loop (cost=0.00..7395.94 rows=28 width=46)" " Output: public.movies.title, public.movies.movieid, public.movies.year" " - Seq Scan on akatitles (cost=0.00..7159.24 rows=28 width=4)" " Output: akatitles.movieid, akatitles.language, akatitles.title, " Filter: (((title)::text ~~* '%Babe%'::text) AND ((title)::text !~~* '""%}'::text))" " - Index Scan using movies_pkey on movies (cost=0.00..8.44 rows=1 width=46)" " Output: public.movies.movieid, public.movies.title, public.movies.year, public.movies.imdbid" " Index Cond: (public.movies.movieid = akatitles.movieid)" SELECT * FROM ((SELECT DISTINCT title, movieid, year FROM movies WHERE title ILIKE '%Babe%' AND NOT (title ILIKE '"%}')) UNION (SELECT movies.title, movies.movieid, movies.year FROM movies INNER JOIN akatitles ON movies.movieid=akatitles.movieid WHERE akatitles.title ILIKE '%Babe%' AND NOT (akatitles.title ILIKE '"%}'))) AS union_tmp2; Returns 612 Rows in 9078ms Database backup (plain text) is 1.61GB It's a really complex query and I am not fully cognizant on it, like I said it was spat out by JMDB. Do you have any suggestions on how I can increase the speed ? Regards Anthoni

    Read the article

  • LINQ compiled query DataBind issue

    - by Brian
    Hello All, I have a pretty extensive reporting page that uses LINQ. There is one main function that returns an IQueryable object. I then further filter / aggregate the returned query depending on the report the user needs. I changed this function to a compiled query, it worked great, and the speed increase was astonishing. The only problem comes when i want to databind the results. I am databinding to a standard asp.net GridView and it works fine, no problems. I am also databinding to an asp.net chart control, this is where my page is throwing an error. this works well: GridView gv = new GridView(); gv.DataSource = gridSource; But this does not: Series s1 = new Series("Series One"); s1.Points.DataBindXY(gridSource, "Month", gridSource, "Success"); The error i receive is this: System.NotSupportedException Specified method is not supported When i look into my gridSource var at run time i see this using a typical linq query: SELECT [t33].[value2] AS [Year], [t33].[value22] AS [Month], [t33].[value3] AS [Calls]...... I see this after i change the query to compiled: {System.Linq.OrderedEnumerable<<>f__AnonymousType15<string,int,int,int,int,int,int,int>,string>} This is obviously the reason why the databindxy is no longer working, but i am not sure how to get around it. Any help would be appreciated! Thanks

    Read the article

  • Entity Framework query

    - by carter-boater
    Hi all, I have a piece of code that I don't know how to improve it. I have two entities: EntityP and EntityC. EntityP is the parent of EntityC. It is 1 to many relationship. EntityP has a property depending on a property of all its attached EntityC. I need to load a list of EntityP with the property set correctly. So I wrote a piece of code to get the EntityP List first.It's called entityP_List. Then as I wrote below, I loop through the entityP_List and for each of them, I query the database with a "any" function which will eventually be translated to "NOT EXIST" sql query. The reason I use this is that I don't want to load all the attached entityC from database to memory, because I only need the aggregation value of their property. But the problem here is, the looping will query the databae many times, for each EntityP! So I am wondering if anybody can help me improve the code to query the database only once to get all the EntityP.IsAll_C_Complete set, without load EntityC to memory. foreach(EntityP p in entityP_List) { isAnyNotComoplete = entities.entityC.Any(c => c.IsComplete==false && c.parent.ID == p.ID); p.IsAll_C_Complete = !isAnyNotComoplete; } Thank you very much!

    Read the article

  • A jscript variable in a Query

    - by lerac
    Maybe a very simple question. How can I put in this code <Query> <Where> <Eq> <FieldRef Name="Judge_x0020_1" /> <Value Type="Text">mr. R. Sanches</Value> </Eq> </Where> </script> </Query> A variable from jscript in the area of the code where mr. R. Sanches is written. So my jScript contains a dynamic text variable I want to replace mr. R. Sanches with. See where it says THE JAVESCRIPT VAR underneath here: <Query> <Where> <Eq> <FieldRef Name="Judge_x0020_1" /> <Value Type="Text">THE JAVASCRIPT VAR</Value> </Eq> </Where> </script> </Query>

    Read the article

  • Setting up a multi-site CMS, collecting thoughts about the DB schema

    - by Ben Fransen
    Hello all, I'm collecting some thoughts about creating a multisite CMS. In my opinion there are two major approaches. All data is stored into 1 database, giving me the advantage of single point of updates; Seperated databases, so each client has its own database. Giving me the advantage to measure bandwith. Option 1 gives me the disadvantage of measuring bandwith while option is giving me the disadvantage of a single point of update structure. Are there any generic approaches for creating a sort of update system? So my clients can download a small package (maybe a zip with a conf file to tell the updatescript where to put all the files and how to extend the database??) Do you guys have some thougths about the best solution for a situation like this? I have my own webserver, full access to all resources and I'm developing in PHP with MySQL as DBMS. I hope to hear from you and I surely appreciate any effort you make to help me further! Greets from Holland, Ben Fransen

    Read the article

  • ValueError with multi-table inheritance in Django Admin

    - by jorde
    I created two new classes which inherit model Entry: class Entry(models.Model): LANGUAGE_CHOICES = settings.LANGUAGES language = models.CharField(max_length=2, verbose_name=_('Comment language'), choices=LANGUAGE_CHOICES) user = models.ForeignKey(User) country = models.ForeignKey(Country, null=True, blank=True) created = models.DateTimeField(auto_now=True) class Comment(Entry): comment = models.CharField(max_length=2000, blank=True, verbose_name=_('Comment in English')) class Discount(Entry): discount = models.CharField(max_length=2000, blank=True, verbose_name=_('Comment in English')) coupon = models.CharField(max_length=2000, blank=True, verbose_name=_('Coupon code if needed')) After adding these new models to admin via admin.site.register I'm getting ValueError when trying to create a comment or a discount via admin. Adding entries works fine. Error msg: ValueError at /admin/reviews/discount/add/ Cannot assign "''": "Discount.discount" must be a "Discount" instance. Request Method: GET Request URL: http://127.0.0.1:8000/admin/reviews/discount/add/ Exception Type: ValueError Exception Value: Cannot assign "''": "Discount.discount" must be a "Discount" instance. Exception Location: /Library/Python/2.6/site-packages/django/db/models/fields/related.py in set, line 211 Python Executable: /usr/bin/python Python Version: 2.6.1

    Read the article

  • Socket Read In Multi-Threaded Application Returns Zero Bytes or EINTR (104)

    - by user309670
    Hi. Am a c-coder for a while now - neither a newbie nor an expert. Now, I have a certain daemoned application in C on a PPC Linux. I use PHP's socket_connect as a client to connect to this service locally. The server uses epoll for multiplexing connections via a Unix socket. A user submitted string is parsed for certain characters/words using strstr() and if found, spawns 4 joinable threads to different websites simultaneously. I use socket, connect, write and read, to interact with the said webservers via TCP on their port 80 in each thread. All connections and writes seems successful. Reads to the webserver sockets fail however, with either (A) all 3 threads seem to hang, and only one thread returns -1 and errno is set to 104. The responding thread takes like 10 minutes - an eternity long:-(. *I read somewhere that the 104 (is EINTR?), which in the network context suggests that ...'the connection was reset by peer'; or (B) 0 bytes from 3 threads, and only 1 of the 4 threads actually returns some data. Isn't the socket read/write thread-safe? I use thread-safe (and reentrant) libc functions such as strtok_r, gethostbyname_r, etc. *I doubt that the said webhosts are actually resetting the connection, because when I run a single-threaded standalone (everything else equal) all things works perfectly right, but of course in series not parallel. There's a second problem too (oops), I can't write back to the client who connect to my epoll-ed Unix socket. My daemon application will hang and hog CPU 100% for ever. Yet nothing is written to the clients end. Am sure the client (a very typical PHP socket application) hasn't closed the connection whenever this is happening - no error(s) detected either. Any ideas? I cannot figure-out whatever is wrong even with Valgrind, GDB or much logging. Kindly help where you can.

    Read the article

  • How to resolve CGDirectDisplayID changing issues on newer multi-GPU Apple laptops in Core Foundation

    - by Dave Gallagher
    In Mac OS X, every display gets a unique CGDirectDisplayID number assigned to it. You can use CGGetActiveDisplayList() or [NSScreen screens] to access them, among others. Per Apple's docs: A display ID can persist across processes and system reboot, and typically remains constant as long as certain display parameters do not change. On newer mid-2010 MacBook Pro's, Apple started using auto-switching Intel/nVidia graphics. Laptops have two GPU's, a low-powered Intel, and a high-powered nVidia. Previous dual-GPU laptops (2009 models) didn't have auto-GPU switching, and required the user to make a settings change, logoff, and then logon again to make a GPU switch occur. Even older systems only had one GPU. There's an issue with the mid-2010 models where CGDirectDisplayID's don't remain the same when a display switches from one GPU to the next. For example: Laptop powers on. Built-In LCD Screen is driven by Intel chipset. Display ID: 30002 External Display is plugged in. Built-In LCD Screen switches to nVidia chipset. It's display ID changes: 30004 External Display is driven by nVidia chipset. ...at this point, the Intel chipset is dormant... User unplugs External Display. Built-In LCD Screen switches back to Intel chipset. It's display ID changes back to original: 30002 My question is, how can I match an old display ID to a new display ID when they alter due to a GPU change? Thought about: I've noticed that the display ID only changes by 2, but I don't have enough test Mac's available to determine if this is common to all new MacBook Pro's, or just mine. Kind of a kludge if "just check for display ID's which are +/-2 from one another" works, anyway. Tried: CGDisplayRegisterReconfigurationCallback(), which notifies before-and-after when displays are going to change, has no matching logic. Putting something like this inside a method registered with it doesn't work: // Run before display settings change: CGDirectDisplayID directDisplayID = ...; io_service_t servicePort = CGDisplayIOServicePort(directDisplayID); CFDictionaryRef oldInfoDict = IODisplayCreateInfoDictionary(servicePort, kIODisplayMatchingInfo); // ...display settings change... // Run after display settings change: CGDirectDisplayID directDisplayID = ...; io_service_t servicePort = CGDisplayIOServicePort(directDisplayID); CFDictionaryRef newInfoDict = IODisplayCreateInfoDictionary(servicePort, kIODisplayMatchingInfo); BOOL match = IODisplayMatchDictionaries(oldInfoDict, newInfoDict, 0); if (match) NSLog(@"Displays are a match"); else NSLog(@"Displays are not a match"); What's happening above is I'm caching oldInfoDict before display settings change, letting them change, and then comparing it to newInfoDict by using IODisplayMatchDictionaries(), which will say either "yes, both displays are the same!" or "no, both displays are not the same." Unfortunately, it does not return YES if GPU's have changed for a monitor. Example of the dictionary's it's comparing: // oldInfoDict (Display ID: 30002) oldInfoDict: { DisplayProductID = 40144; DisplayVendorID = 1552; IODisplayLocation = "IOService:/AppleACPIPlatformExpert/PCI0@0/AppleACPIPCI/IGPU@2/AppleIntelFramebuffer/display0/AppleBacklightDisplay"; } // newInfoDict (Display ID: 30004) newInfoDict: { DisplayProductID = 40144; DisplayVendorID = 1552; IODisplayLocation = "IOService:/AppleACPIPlatformExpert/PCI0@0/AppleACPIPCI/P0P2@1/IOPCI2PCIBridge/GFX0@0/NVDA,Display-A@0/NVDA/display0/AppleBacklightDisplay"; } As you can see, the IODisplayLocation key changes when GPU's are switched, hence IODisplayMatchDictionaries() doesn't work. I can, theoretically, compared just the DisplayProductID and DisplayVendorID keys, but I'm writing end-user software, and am worried of a situation where users have two or more identical monitors plugged in. Any help is greatly appreciated! :)

    Read the article

  • Mysql - Help me alter this search query to get desired results

    - by sandeepan-nath
    Following is a dump of the tables and data needed to answer understand the system:- The system consists of tutors and classes. The data in the table All_Tag_Relations stores tag relations for each tutor registered and each class created by a tutor. The tag relations are used for searching classes. CREATE TABLE IF NOT EXISTS `Tags` ( `id_tag` int(10) unsigned NOT NULL auto_increment, `tag` varchar(255) default NULL, PRIMARY KEY (`id_tag`), UNIQUE KEY `tag` (`tag`), KEY `id_tag` (`id_tag`), KEY `tag_2` (`tag`), KEY `tag_3` (`tag`), KEY `tag_4` (`tag`) ) ENGINE=InnoDB DEFAULT CHARSET=latin1; INSERT INTO `Tags` (`id_tag`, `tag`) VALUES (1, 'Sandeepan'), (2, 'Nath'), (3, 'first'), (4, 'class'), (5, 'new'), (6, 'Bob'), (7, 'Cratchit'); CREATE TABLE IF NOT EXISTS `All_Tag_Relations` ( `id_tag` int(10) unsigned NOT NULL default '0', `id_tutor` int(10) default NULL, `id_wc` int(10) unsigned default NULL, KEY `All_Tag_Relations_FKIndex1` (`id_tag`), KEY `id_wc` (`id_wc`), KEY `id_tag` (`id_tag`) ) ENGINE=InnoDB DEFAULT CHARSET=latin1; INSERT INTO `All_Tag_Relations` (`id_tag`, `id_tutor`, `id_wc`) VALUES (1, 1, NULL), (2, 1, NULL), (3, 1, 1), (4, 1, 1), (6, 2, NULL), (7, 2, NULL), (5, 2, 2), (4, 2, 2); Following is my query:- This query searches for "first class" (tag for first = 3 and for class = 4, in Tags table) and returns all those classes such that both the terms first and class are present in the class name. SELECT wtagrels.id_wc,SUM(DISTINCT( wtagrels.id_tag =3)) AS key_1_total_matches, SUM(DISTINCT( wtagrels.id_tag =4)) AS key_2_total_matches FROM all_tag_relations AS wtagrels WHERE ( wtagrels.id_tag =3 OR wtagrels.id_tag =4 ) GROUP BY wtagrels.id_wc HAVING key_1_total_matches = 1 AND key_2_total_matches = 1 LIMIT 0, 20 And it returns the class with id_wc = 1. But, I want the search to show all those classes such that all the search terms are present in the class name or its tutor name So that searching "Sandeepan class" (wtagrels.id_tag = 1,4) or "Sandeepan Nath" also returns the class with id_wc=1. And Searching. Searching "Bob First" should not return any classes. Please modify the above query or suggest a new query, if possible using MyIsam - fulltext search, but somehow help me get the result.

    Read the article

  • Windows Screensaver Multi Monitor Problem

    - by Bryan
    I have a simple screensaver that I've written, which has been deployed to all of our company's client PCs. As most of our PCs have dual monitors, I took care to ensure that the screensaver ran on both displays. This works fine, however on some systems, where the primary screen has been swapped (to the left monitor), the screensaver only works on the left (primary) screen. The offending code is below. Can anyone see anything I've done wrong, or a better way of handling this? For info, the context of "this", is the screensaver form itself. // Make form full screen and on top of all other forms int minY = 0; int maxY = 0; int maxX = 0; int minX = 0; foreach (Screen screen in Screen.AllScreens) { // Find the bounds of all screens attached to the system if (screen.Bounds.Left < minX) minX = screen.Bounds.Left; if (screen.Bounds.Width > maxX) maxX = screen.Bounds.Width; if (screen.Bounds.Bottom < minY) minY = screen.Bounds.Bottom; if (screen.Bounds.Height > maxY) maxY = screen.Bounds.Height; } // Set the location and size of the form, so that it // fills the bounds of all screens attached to the system Location = new Point(minX, minY); Height = maxY - minY; Width = maxX - minX; Cursor.Hide(); TopMost = true;

    Read the article

  • MySQL Query Error

    - by Nano HE
    I am debug my php forum. Before the error,I modified the DB table name from cdb_sessions to imc_forum_sessions successfully. I tried my best to debug with NetBeans but can't find the reason. Could you please have a look at my post below. Thank you. // It will run to else during debug if($sid) { if($discuz_uid) { $query = $db->query("SELECT s.sid, s.styleid, s.groupid='6' AS ipbanned, s.pageviews AS spageviews, s.lastolupdate, s.seccode, $membertablefields FROM {$tablepre}sessions s, {$tablepre}members m WHERE m.uid=s.uid AND s.sid='$sid' AND CONCAT_WS('.',s.ip1,s.ip2,s.ip3,s.ip4)='$onlineip' AND m.uid='$discuz_uid' AND m.password='$discuz_pw' AND m.secques='$discuz_secques'"); } else { $query = $db->query("SELECT sid, uid AS sessionuid, groupid, groupid='6' AS ipbanned, pageviews AS spageviews, styleid, lastolupdate, seccode FROM {$tablepre}sessions WHERE sid='$sid' AND CONCAT_WS('.',ip1,ip2,ip3,ip4)='$onlineip'"); } } MySQL data table exported as below CREATE TABLE IF NOT EXISTS `imc_forum_sessions` ( `sid` char(6) NOT NULL DEFAULT '', `ip1` tinyint(3) unsigned NOT NULL DEFAULT '0', `ip2` tinyint(3) unsigned NOT NULL DEFAULT '0', `ip3` tinyint(3) unsigned NOT NULL DEFAULT '0', `ip4` tinyint(3) unsigned NOT NULL DEFAULT '0', `uid` mediumint(8) unsigned NOT NULL DEFAULT '0', `username` char(15) NOT NULL DEFAULT '', `groupid` smallint(6) unsigned NOT NULL DEFAULT '0', `styleid` smallint(6) unsigned NOT NULL DEFAULT '0', `invisible` tinyint(1) NOT NULL DEFAULT '0', `action` tinyint(1) unsigned NOT NULL DEFAULT '0', `lastactivity` int(10) unsigned NOT NULL DEFAULT '0', `lastolupdate` int(10) unsigned NOT NULL DEFAULT '0', `pageviews` smallint(6) unsigned NOT NULL DEFAULT '0', `seccode` mediumint(6) unsigned NOT NULL DEFAULT '0', `fid` smallint(6) unsigned NOT NULL DEFAULT '0', `tid` mediumint(8) unsigned NOT NULL DEFAULT '0', `bloguid` mediumint(8) unsigned NOT NULL DEFAULT '0', UNIQUE KEY `sid` (`sid`), KEY `uid` (`uid`), KEY `bloguid` (`bloguid`) ) ENGINE=MEMORY DEFAULT CHARSET=utf8 MAX_ROWS=5000; -- -- Dumping data for table `imc_forum_sessions` -- INSERT INTO `imc_forum_sessions` (`sid`, `ip1`, `ip2`, `ip3`, `ip4`, `uid`, `username`, `groupid`, `styleid`, `invisible`, `action`, `lastactivity`, `lastolupdate`, `pageviews`, `seccode`, `fid`, `tid`, `bloguid`) VALUES ('NYC4r7', 127, 0, 0, 1, 0, '', 6, 5, 0, 3, 1271372018, 0, 0, 939015, 51, 303, 0); And the IE error showed, Time: 2010-4-16 7:12am Script: /forum/index.php SQL: SELECT sid, uid AS sessionuid, groupid, groupid='6' AS ipbanned, pageviews AS spageviews, styleid, lastolupdate, seccode FROM [Table]sessions WHERE sid='NYC4r7' AND CONCAT_WS('.',ip1,ip2,ip3,ip4)='127.0.0.1' Error: Table 'dbbbs.[Table]sessions' doesn't exist Errno.: 1146 Similar error report has beed dispatched to administrator before.

    Read the article

  • Group functions of outer query inside inner query

    - by superdario
    Hello, I'm using Oracle. I'm trying to compose something like this: SELECT trans_type, (SELECT parameter_value FROM transaction_details WHERE id = MAX(t.trans_id)) FROM (SELECT trans_id, trans_type FROM transactions) t GROUP BY trans_type So, I am trying to use a result of grouping inside an inner query. But I am getting the error that I cannot use a group function inside the inner query: ORA-00934: group function is not allowed here Can you offer an alternative other than resorting to another outer query?

    Read the article

< Previous Page | 9 10 11 12 13 14 15 16 17 18 19 20  | Next Page >