Search Results

Search found 6343 results on 254 pages for 'dll injection'.

Page 130/254 | < Previous Page | 126 127 128 129 130 131 132 133 134 135 136 137  | Next Page >

  • CommandManager "cannot resolve symbol"

    - by Budda
    After adding "RelayCommand" class (that uses CommandManager class) into my Silverlight App I've got an error: The name 'CommandManager' does not exist in the current context This class is a member of System.Windows.Input namespace that is in PresentationCore.dll assembly. The problem is that I can't add this dll into my app... I am having a strange assumption: this class (CommmandManager) can't be used in the Silverlight. Am I right? How can I implement MVVM-pattern (http://msdn.microsoft.com/en-us/magazine/dd419663.aspx)? Thanks.

    Read the article

  • Array index is not accessable because it is Friend

    - by user3738194
    I am getting and error when I bring my code into another project. In a blank project it works fine, I really have no idea how to get around it, here is the error Error 1 'System.Data.Index' is not accessible in this context because it is 'Friend'. Dim DataString As String = txtAdvancedCommand.Text ' Create an array containing from each letter in Textbox Dim charArray() As Char = DataString.ToCharArray For index = 0 To charArray.GetUpperBound(0) <-----ERROR on word index Try 'Now lets send the data If SerialPort.IsOpen Then SerialPort.Write(charArray(index) & vbCrLf) <-----ERROR on word index Else ConnectSerial() SerialPort.Write(charArray(index) & vbCrLf) <-----ERROR on word index End If Catch e As Exception txtLog.AppendText(e.Message & vbCrLf) End Try Next now the project I am bringing into has a DLL and I suspect it has something to do with it, I cannot get the source code to the DLL so is there another way around this?

    Read the article

  • Cant get Tomcat6.0 to work with Windows 7 Environment

    - by CitadelCSCadet
    Prior to upgrading to windows 7, I was able to use Tomcat 6.0, but when I upgraded to the new Windows, and downloaded Eclipse EE, and downloaded the apache content, I am unable to get Apache to run. When I attempt to start my apacher server through either system tray, or even windows services, it gives the followign error screen. "Windows could not start the Apache Tomcat 6 on local computer. For more information review the system event log. Refer to server specific error code 0." I have been able to locate some forums about error code 0, and some other documentation on this problem, but none of the solutions seems to work. One of the solutions I came across said to take the msvcr71.dll (mscvrt.dll on new platforms) and put it into the bin folder of apache. This also did not work. Does anybody know a fix for this problem, or a way to get around it so I can get my server up and running thanks.

    Read the article

  • Visual Studio - how to create two projects using the same sources

    - by mack369
    My solution consists of 2 executable projects and a couple dlls. Project1 is a Smart Device Project, Project2 is a Windows Forms Project. Both projects use the same libraries, the reason of that is I want to test my libraries on PC before I deploy it on the device. The problem is that the DLL project type can be Smart Device Class Library or Class Library, not both. I cannot add a reference from SD project to WF and vice versa. I was able to add reference from SD project to a dll file (generated from Class Library project) instead of the project itself, but for some reason I got the message "cannot load XXX type from YYY assembly". It doesn't depend on my code, because when I created separate project for the same sources, everything was fine. The only solution I've found is to create 2 types of projects for each library, but I don't know how to make 2 projects based on the same sources.

    Read the article

  • How do I play flash files in pure C?

    - by CDR
    As part of a customized media player written in C (Win32), I need to enable my app play flash movies (.swf files) inside the player window. Can someone please indicate the most C compatible low level way to achieve this, giving me highest control? Specially control on display window and network access. I am looking for reference to a Windows DLL like flash_player.dll (if there is such thing) with documentation. Or at least a COM/ActiveX controls. Note that ActiveX is harder to use in C, than in say VB.

    Read the article

  • RMO on Windows 7 - The Specified module could not be found

    - by AGoodDisplayName
    My machine: Windows XP (x86), VS2008, .net 3.5, sql server 2005, WinForms - App works fine. Production Machines: Windows 7 (x64), SQl Server 2005 Express - App Starts but throws exception Visual Studio Targeting x86 on setup project and RMO project. Visual Studio gives me a a couple warnings but I can still build: Unable to find dependency 'MICROSOFT.SQLSERVER.MANAGEMENT.SQLPARSER' (Signature='89845DCD8080CC91' Version='10.0.0.0') of assembly 'Microsoft.SqlServer.Smo.dll' Unable to find dependency 'MICROSOFT.SQLSERVER.MANAGEMENT.SQLPARSER' (Signature='89845DCD8080CC91' Version='10.0.0.0') of assembly 'Microsoft.SqlServer.Management.SmoMetadataProvider.dll' This is a simple RMO (Replication Management Objects) app that initiates a pull subscription in SQL Server 2005 and displays status. Works fine on my machine, but fails on the production machine. I'm using a setup project to install the app on the production machine, but I think I'm missing a dependency somewhere, but I can't figure it out. On the production machine the app starts fine, but when I try to synch the subscription i get: System.IO.FileNotFoundException: The Specified module could not be found. (Exception from HResult: 0x8007007E)

    Read the article

  • Problems debugging using Cygwin gdb in Eclipse CDT(Helios)

    - by Rohan
    I am trying to debug an application using Eclipse CDT and cygwin gdb and I am facing a problem if my code calls Sleep(), it looks like whenever a sleep is encountered in the code the debugger seems to go in an infinite loop(I meant it never terminates or hit a breakpoint after sleep). On pressing pause the code is stuck on one of the thread on sigint::interrupt. Even my debugger console windows throw these error in the console output: [New thread 5968.0x1f98] Error: dll starting at 0x774a0000 not found. Error: dll starting at 0x775c0000 not found. [New thread 5968.0x19e8] Any idea what are these errors about? It would be helpful if someone can help me out here as I am new to eclipse and I am used to using VS so it has made be lazy to be honest and expect things to work out of box. Here are more details if required Windows 7 x64 bit. Eclipse 3.6 Helios with CDT plug-in compiled from the CVS head. Cygwin latest from website, I think it is 1.71

    Read the article

  • Casting between variant and bstr_t causing inconsisten crash in Windows 2008

    - by user58470
    We have a C# application, calling a simple C++ wrapper class, that then calls an existing C++ DLL. The C++ code is all VC++ 6.0. We are getting inconsistent behaviour, but the crash, when it happens, always happens within the C++ wrapper DLL, and always in the same spot (have confirmed using painful logging statements). It never happens on any environment except on Windows 2008, so we suspect some bad-but-not-fatal memory trashing is going on that somehow Windows 2008 is being more mindful of. Here's the relevant code, if anyone has any ideas on why this might be crashing it would be much appreciated. We've been tearing our hair out for a few days and project timelines are slipping all for the want of being able to return a simple string back to C#... I've been told we've tried setting the VARIANT vresult using VariantInit, and clearing it when we are done with VariantClear, but that didn't help. // JobMgrDll.cpp : Defines the entry point for the DLL application. // #include "stdafx.h" #include "JobMgrDll.h" #include "jobmgr.h" CString gcontext; CString guser; CString ghost; CString glog; JOBMGRDLL_API int nJobMgrDll=0; extern "C" JOBMGRDLL_API char* perform_billcalc(char* cmd, char* context, char* user,char* host,BSTR* log,int* loglen) { char* result = new char[1000]; memset(result,0,999); result[999] = '\0'; bstr_t bt_command = cmd; UUID uuid = __uuidof(BRLib::Rules); VARIANT vresult; char *p_rv; gcontext = context; guser = user; ghost = host; write_log("execute_job"); p_rv = execute_job(uuid, "none", bt_command, &vresult); write_log("DONE execute_job"); CString message; write_log ("Intializing bstr_t with variant"); // WE ALWAYS GET HERE bstr_t res(vresult); //message.Format("%s result = %s",p_rv,res); //write_log(message); write_log("copying Result"); // WE DON'T ALWAYS GET HERE, BUT SOMETIMES WE DO strcpy(result,(char*)res); write_log(CString(result)); *loglen = glog.GetLength(); *log = glog.AllocSysString(); return result; } Again, any ideas much, much appreciated.

    Read the article

  • P-invoke call fails if too much memory is assigned beforehand

    - by RandomEngy
    I've got a p-invoke call to an unmanaged DLL that was failing in my WPF app but not in a simple, starter WPF app. I tried to figure out what the problem was but eventually came to the conclusion that if I assign too much memory before making the call, the call fails. I had two separate blocks of code, both of which would succeed on their own, but that would cause failure if both were run. (They had nothing to do with what the p-invoke call is trying to do). What kind of issues in the unmanaged library would cause such an issue? I thought that the managed and unmanaged heaps were supposed to be automatically separated. The crash as far as I can tell is happening in a dynamically loaded secondary DLL from the one p-invoked into. Could that have something to do with it?

    Read the article

  • How to initialize one class from a library?

    - by daemonsvk
    Hi, I have a few classes in the class library (separate assembly). I referenced it to my project and I want to initialize one specific class from that library. I know only its name. All of the classes implements one interface. And here comes the problem. My code so far: using MyLibrary; ... IMyInterface dll = Activator.CreateInstance("MyLibrary", "MyLibrary.NameOfClass") as IMyInterface; But dll is always null. Any ideas? Thanks

    Read the article

  • Losing scope for DataContex using LINQToSQL intermediately

    - by greektreat
    I am having a weird Situation with my DataConext. All My code is in C# I have a DLL project for my data access layer and business Layer which and Winforms project for my UI layer. My Data access Layer's Namespace is xxx.Data this is where have my xxx.dbml I also have xxx.Data.BusinessObjects name space of course for my business object in that project In my UI Layer I have these namespaces xxxApp(for Forms), xxxApp.Controls (For Controls) I have lost scope of the DataContext, it was accessible now when I do a Rebuild Solution I sometimes get compile errors saying for example: Error 34 'xxx.Data.xxxDataContext' does not contain a definition for 'SubmitChanges' and no extension method 'SubmitChanges' accepting a first argument of type 'xxx.Data.xxxDataContext' could be found (are you missing a using directive or an assembly reference?) Also intelisense doesn't recognize the methods and table classes from my xxxDataContext anymore I can access all object fine when I am in the DLL project but now in the Winforms project this is very strange. If anyone can help me out I would be extremely grateful!

    Read the article

  • F# powerpack and distribution

    - by rwallace
    I need arbitrary precision rational numbers, which I'm given to understand are available in the F# powerpack. My question is about the mechanics of distribution; my program needs to be able to compile and run both on Windows/.Net and Linux/Mono at least, since I have potential users on both platforms. As I understand it, the best procedure is: Download the powerpack .zip, not the installer. Copy the DLL into my program directory. Copy the accompanying license file into my program directory, to make sure everything is above board. Declare references and go ahead and use the functions I need. Ship the above files along with my source and binary, and since the DLL uses byte code, it will work fine on any platform. Is this the correct procedure? Am I missing anything?

    Read the article

  • Play mp3 stream from http URL on Windows Mobile 6.0

    - by Thyphuong
    After a short period of time learning about how to play a mp3 http url on windows mobile 6.0, I found that very less dll support that (until now, I just found out Bass.dll work nice). So I intend to change to another way to approach the goal. Here's my idea: Get a stream from http url. Decode the mp3 stream. Play the result from step 2. Coz I'm new on this field, so feel free and explain to me what I'm wrong and/or show me the way.

    Read the article

  • Log4net 1.2.10 running on .NET 1.1 and 2.0 not compatible

    - by Daniel Williams
    I have old code that uses log4net version 1.2.10 targeted for the .NET 1.1 platform. My current code uses lognet version 1.2.10 targeted for the .NET 2.0 platform When I mix the old and new code all hell breaks loose. Code written today on .NET 4.0 and VS2010 can use the 2.0 log4net dll just fine. but if I put in the 1.1 version, it breaks. Conversely, the old dlls will break if I use the 2.0 log4net dll. I do not want to force my old dlls onto 2.0. Is there a good solution? I guess what bugs me most is that the log4net has the same version number, but I cannot fool my code and dlls into working with a single version.

    Read the article

  • Temporary files & folders on Windows

    - by GRIGORE-TURBODISEL
    Emulating multithreading by loading a DLL multiple times (it's designed for this). Since LoadLibrary() doesn't really allow it, the DLL copies itself into a temporary file, via GetTempPath() and GetTempFileName(). It's a small file and upon thread destruction it frees the library and deletes the temporary file. Problem now is that the number of threads is configurable (maniacs can pick 50, 100, more) which basically exposes the risk of running unstable, crash and not go through the usual "delete temporary files" routine. Is it okay if I just leave those temporary files to die there? Does the OS usually clean the up by itself? Or should I write an autocleanup routine? If yes, how can I go about saving another temporary file to hold a list with those files, and not hit UAC restrictions or otherwise? Any ideas?

    Read the article

  • Enable GD support in PHP

    - by Don
    Hi, I'm trying to install pixelpost on an Apache server on windows. The installer is failing because: Pixelpost will not run if your PHP installation is not compiled with the GD graphics library. I've added the following line to php.ini extension=php_gd2.dll But I still get the same error message. When I run phpinfo() I don't see any reference to GD, so I guess it really isn't installed. I searched for php_gd2.dll and it's in the ext subfolder of my PHP root dir. I know nothing about PHP, so be gentle with me. Thanks, Don

    Read the article

  • Why does DebugActiveProcessStop crash my debugging app?

    - by SparkyNZ
    I have a debugging program which I've written to attach to a process and create a crash dump file. That part works fine. The problem I have is that when the debugger program terminates, so does the program that it was debugging. I did some Googling and found the DebugActiveProcessStop() API call. This didn't show up in my older MSDN documentation as it was only introduced in Windows XP so I've tried loading it dynamicall from Kernel32.dll at runtime. Now my problem is that my debugger program crashes as soon as the _DebugActiveProcessStop() call is made. Can somebody please tell me what I'm doing wrong? typedef BOOL (*DEBUGACTIVEPROCESSSTOP)(DWORD); DEBUGACTIVEPROCESSSTOP _DebugActiveProcessStop; HMODULE hK32 = LoadLibrary( "kernel32.dll" ); if( hK32 ) _DebugActiveProcessStop = (DEBUGACTIVEPROCESSSTOP) GetProcAddress( hK32,"DebugActiveProcessStop" ); else { printf( "Can't load Kernel32.dll\n" ); return; } if( ! _DebugActiveProcessStop ) { printf( "Can't find DebugActiveProcessStop\n" ); return; } ... void DebugLoop( void ) { DEBUG_EVENT de; while( 1 ) { WaitForDebugEvent( &de, INFINITE ); switch( de.dwDebugEventCode ) { case CREATE_PROCESS_DEBUG_EVENT: hProcess = de.u.CreateProcessInfo.hProcess; break; case EXCEPTION_DEBUG_EVENT: // PDS: I want a crash dump immediately! dwProcessId = de.dwProcessId; dwThreadId = de.dwThreadId; WriteCrashDump( &de.u.Exception ); return; case CREATE_THREAD_DEBUG_EVENT: case OUTPUT_DEBUG_STRING_EVENT: case EXIT_THREAD_DEBUG_EVENT: case EXIT_PROCESS_DEBUG_EVENT : case LOAD_DLL_DEBUG_EVENT: case UNLOAD_DLL_DEBUG_EVENT: case RIP_EVENT: default: break; } ContinueDebugEvent( de.dwProcessId, de.dwThreadId, DBG_CONTINUE ); } } ... void main( void ) { ... BOOL bo = DebugActiveProcess( dwProcessId ); if( bo == 0 ) printf( "DebugActiveProcess failed, GetLastError: %u \n",GetLastError() ); hProcess = OpenProcess( PROCESS_ALL_ACCESS, TRUE, dwProcessId ); if( hProcess == NULL ) printf( "OpenProcess failed, GetLastError: %u \n",GetLastError() ); DebugLoop(); _DebugActiveProcessStop( dwProcessId ); CloseHandle( hProcess ); }

    Read the article

  • How can I create an http handler to redirect all traffic to HTML pages?

    - by Eitan
    Our company would like to redirect all calls to html files on our server to a separate page. The html pages are NOT in an asp.net application. In order to do this, I've been writing and IIS Handler in asp.net. 1) Is this possible to add an IIS handler to redirect static content that isn't served by any asp.net engine, i.e. stand alone files on the server? 2) If it is possible, how do I do this? I created an http handler in a class library. In the app.config I added the handler to the and sections. I added the DLL to the GAC, I changed the html mapping to my custom IIS dll and nothing works. Is there a tutorial or explanation from A to B on how to do this? Thanks. E p.s. I'm using IIS 7.5

    Read the article

  • Are folks using the VB6 "Common Controls Replacement Project" controls? Any caveats or showstoppers?

    - by Clay Nichols
    I'm considering using the VB6 Common Controls Replacement Project controls and would like to see what other's experiences with them are. Specifically: What do you need to distribute with them? (I assume just the .OCX file) Do I need to register the .ocx file or just include in the app directory? Do these controls depend on any other ocx's? (There is mention, for example in the Progress Bar replacement that it is using COMCTL32.DLL but the .DEP file does not list that DLL. Are they at least as robust as the controls they replace?

    Read the article

  • How we run a .NET 32-bit application in a 64-bit Windows server?

    - by Geo
    We are installing a third party application in one of our 64-bit Windows servers. This application apparently was build with the compiler option set to choose the platform at run time. When we run the application it gives us an error: System.BadImageFormatException: is not a valid Win32 application. I have seen in MSDN forums that in order to fix this error I have to build the application set to 32-bit, and that way it will run fine on a 64-bit server. I check on other StackOverflow links Other Posts. How to get around this situation? For everyone that wants to know more information: The application is running fine in a 32-bit test server. IIS version 6 using SQL Server Express 2005 On the Web Service Extension there are both Framework64\v2.0.50727\aspnet_isapi.dll and Framework\v2.0.50727\aspnet_isapi.dll

    Read the article

  • SDL/Pygame failing to load PNG images with cx_Freeze

    - by jjackson
    I'm running Python 3.1 on Windows and I'm trying to distribute my Pygame script as an executable via cx_Freeze. Right now it seems to be working except that the exe build can't load any of my images: Cannot load image: C:\path\to\build\exe.win32-3.1\resources\image.png File is not a Windows BMP file Googling has revealed that this happens when the SDL imaging library doesn't get included correctly. However, SDL_image.dll and libpng12-0.dll are both put by cx_Freeze into my build directory, so it seems to me like everything should be fine. Why wouldn't it be able to load PNG images?

    Read the article

  • Using different versions of the same assembly.

    - by AngryHacker
    I have a project where I simultaneously must use reports built in ActiveReports 2 and ActiveReports 6. Overall, it works ok, but some of the helper assemblies use the same name. For instance, to be able to export to PDF, both versions use an assembly called ActiveReports.PdfExport.dll. The corresponding assemblies are different, of course. Note that I don't access the ActiveReports.PdfExport.dll directly - this is handled by the ActiveReports runtime. I can't find a way to include both of them into the project. Is there a way? Is GAC the answer?

    Read the article

  • References not shown in visual studio

    - by Dofs
    Hi, I have an ASP.NET 3.5 website project, where I have added a few assemblies. When I look in the bin folder in visual studio the references are not shown, but if I go to the references in the property pages for the website they are shown as GAC. Shouldn't dll's in GAC be shown under references for a website project in visual studio? The core problem is that I am getting an error that System.Core could not be loaded. The dll-file is shown under references under the project pages, but is not shown under bin in visual studio.

    Read the article

  • Error after switching from .NET 3.5 to 4

    - by Queops
    Application.Run(new Main()); This line gives TypeInitializationException was unhandled after I switched from 3.5 to 4 framework. Why is this? Edit: Forgot to mention this is a Winforms C# application. Okay so I have SQLite .NET referenced. I tried this on a project created on .NET 4 by default and didn't give me any error so I assumed it wasn't about SQLite .NET http://sqlite.phxsoftware.com/ Please note v2.0.50727 this is the runtime version of the DLL which seems to be causing the problem. Thrown: "A assemblagem de modo misto foi criada com base na versão 'v2.0.50727' do tempo de execução e não é possível carregá-la no tempo de execução 4.0 sem informações de configuração adicionais." (System.IO.FileLoadException) Exception Message = "A assemblagem de modo misto foi criada com base na versão 'v2.0.50727' do tempo de execução e não é possível carregá-la no tempo de execução 4.0 sem informações de configuração adicionais.", Exception Type = "System.IO.FileLoadException" Seems he can't run the DLL on v4 with/ extra configuration.

    Read the article

  • Windows batch file: is there a way to add an "and"?

    - by Beska
    The short version: is there a way to to write an "and" clause in a batch file? The slightly longer version: I've inherited a Visual Studio project that creates a dll and then copies that dll to another location. As a post build step, VS runs the following script. if not '$(ConfigurationName)' == 'DebugNoSvc' goto end xcopy /Y $(TargetDir)*.config $(ProjectDir)..\myService\bin\Debug xcopy /Y $(TargetDir)*.config $(ProjectDir)..\myService\bin\DebugNoSvc :end It looks like there's a problem when the project is compiled as Debug, since it doesn't do the copy (I'm guessing that at some point the middle section got updated, but the if clause didn't.) Is there an easy way to an "and" clause in batch?

    Read the article

< Previous Page | 126 127 128 129 130 131 132 133 134 135 136 137  | Next Page >