The File/Ftp Adapter allows the user to configure the outbound write to use a sequence number. For example, if I choose address-data_%SEQ%.txt as the FileNamingConvention, then all my files would be generated as address-data_1.txt, address-data_2.txt,...and so on.
But, where does this sequence number come from? The answer lies in the "control directory" for the particular adapter project(or scenario). In general, for every project that use the File or Ftp Adapter, a unique directory is created for book keeping purposes. And since this control directory is required to be unique, the adapter uses a digest to make sure that no two control directories are the same. For example, for my FlatStructure sample, the control information for my project would go under FMW_HOME/user_projects/domains/soainfra/fileftp/controlFiles/[DIGEST]/outbound where the value of DIGEST would differ from one project to another.
If you look under this directory, you will see a file control_ob.properties and this is where the sequence number is maintained. Please note that the sequence number is maintained in binary form and you hence you might need a hex editor to view its content. You will also see another zero byte file, SEQ_nnn, but, ignore that for now. We'll get to it some other time. For now, please remember that this extra file is maintained as a backup.
One of the challenges faced by the adapter runtime is to guard all writes to the control files so no two threads inadverently try to update them at the same time. And, it does so with the help of a "Mutex". For now, please remember that the mutex comes in different flavors:
In-memory
DB-based
Coherence-based
User-defined
Again, we will talk about these mutexes some other time.
Please note that there might be scenarios, particularly under heavy load, where the mutex might become a bottleneck. The adapter, however, allows you to change the configuration so that the adapter sequence value comes from a database sequence or a stored procedure and in such situation, the mutex is acually by-passed and thereby resulting in better throughputs. In later releases, the behavior of the adapter would be defaulted to use a db-sequence.
The simplest way to achieve this is by switching your JNDI for the outbound JCA file to use "eis/HAFileAdapter" as shown
But, what does this do? Internally, the adapter runtime creates a sequence on the oracle database. For example, if you do a "select * from user_sequences" in your soa-infra schema, you will see a new sequence being created with name as SEQ_<GUID>__ where the GUID will differ from one project to another. However, if you want to use your own sequence, then it would require you to add a new property to your JCA file called SequenceName as shown below. Please note that you will need to create this sequence on your soainfra schema beforehand.
But, what if we use DB2 or MSSQL Server as the dehydration support? DB2 supports sequences natively but MSSQL Server does not. So, the adapter runtime uses a natively generated sequence for DB2, but, for MSSQL server, the adapter relies on a stored procedure that ships with the product.
If you wish to achieve the same result for SOA Suite running DB2 as the dehydration store, simply change your connection factory JNDI name in the JCA file to eis/HAFileAdapterDB2 and for MSSQL, please use eis/HAFileAdapterMSSQL.
And, if you wish to use a stored procedure other than the one that ships with the product, you will need to rely on binding properties to override the adapter behavior. Particularly, you will need to instruct the adapter that you wish to use a stored procedure as shown:
Please note that if you're using the File/Ftp Adapter in Append mode, then the adapter runtime degrades the mutex to use pessimistic locks as we don't want writers from different nodes to append to the same file at the same time.