Search Results

Search found 22521 results on 901 pages for 'output redirect'.

Page 136/901 | < Previous Page | 132 133 134 135 136 137 138 139 140 141 142 143  | Next Page >

  • How to keep confirmation messages after POST while doing a post-submit redirect?

    - by MicE
    Hello, I'm looking for advise on how to share certain bits of data (i.e. post-submit confirmation messages) between individual requests in a web application. Let me explain: Current approach: user submits an add/edit form for a resource if there were no errors, user is shown a confirmation with links to: submit a new resource (for "add" form) view the submitted/edited resource view all resources (one step above in hierarchy) user then has to click on one of the three links to proceed (i.e. to the page "above") Progmatically, the form and its confirmation page are one set of classes. The page above that is another. They can technically share code, but at the moment they are both independent during processing of individual requests. We would like to amend the above as follows: user submits an add/edit form for a resource if there were no errors, the user is redirected to the page with all resources (one step above in hierarchy) with one or more confirmation messages displayed at the top of the page (i.e. success message, to whom was the request assigned, etc) This will: save users one click (they have to go through a lot of these add/edit forms) the post-submit redirect will address common problems with browser refresh / back-buttons What approach would you recommend for sharing data needed for the confirmation messages between the two requests, please? I'm not sure if it helps, it's a PHP application backed by a RESTful API, but I think that this is a language-agnostic question. A few simple solutions that come to mind are to share the data via cookies or in the session, this however breaks statelessness and would pose a significant problem for users who work in several tabs (the data could clash together). Passing the data as GET parameters is not suitable as we are talking about several messages which are dynamic (e.g. changing actors, dates). Thanks, M.

    Read the article

  • how can i redirect page while download box appears?

    - by Ronnie Chester Lynwood
    Now I got this code; <?php $file = "pain.png"; if (file_exists($file)) { header('Content-Description: File Transfer'); header('Content-Type: application/octet-stream'); header('Content-Disposition: attachment; filename='.basename($file)); header('Content-Transfer-Encoding: binary'); header('Expires: 0'); header('Cache-Control: must-revalidate, post-check=0, pre-check=0'); header('Pragma: public'); header('Content-Length: ' . filesize($file)); ob_clean(); flush(); readfile($file); exit; } ?> This code appears a download box. But I want to redirect this page to "Thank You" page while download box still here. How can i do this? Thanks...

    Read the article

  • What is Rails way to DRY up the controller pattern of verifying :id is for a valid object (else redirect to error page)

    - by jpwynn
    One of my controllers has close to 100 methods (eg routes) and nearly every one starts out the same code to redirect to an error page if the id param is invalid, followed by a similar check if the user that id doesn't belong in the user's account: def something @foo = Foo.find_by_guid(params[:id]) unless @foo @msg ||= { :title => 'No such page!', :desc => "There is no such page!" } render :action => "error" and return end unless @foo.owner_id == current_user.id @msg ||= { :title => 'Really?', :desc => "There is no such page." } render :action => "error" and return end What is the best way to DRY up that sort of page id and owner id validation, given the code is doing a render ... and return? What I don't want to do at this point is offload it to a blackbox roles and permissions library like CanCan... my goal is simply to have the in-app code to handle this be as clean as possible.

    Read the article

  • Flow-Design Cheat Sheet &ndash; Part I, Notation

    - by Ralf Westphal
    You want to avoid the pitfalls of object oriented design? Then this is the right place to start. Use Flow-Oriented Analysis (FOA) and –Design (FOD or just FD for Flow-Design) to understand a problem domain and design a software solution. Flow-Orientation as described here is related to Flow-Based Programming, Event-Based Programming, Business Process Modelling, and even Event-Driven Architectures. But even though “thinking in flows” is not new, I found it helpful to deviate from those precursors for several reasons. Some aim at too big systems for the average programmer, some are concerned with only asynchronous processing, some are even not very much concerned with programming at all. What I was looking for was a design method to help in software projects of any size, be they large or tiny, involing synchronous or asynchronous processing, being local or distributed, running on the web or on the desktop or on a smartphone. That´s why I took ideas from all of the above sources and some additional and came up with Event-Based Components which later got repositioned and renamed to Flow-Design. In the meantime this has generated some discussion (in the German developer community) and several teams have started to work with Flow-Design. Also I´ve conducted quite some trainings using Flow-Orientation for design. The results are very promising. Developers find it much easier to design software using Flow-Orientation than OOAD-based object orientation. Since Flow-Orientation is moving fast and is not covered completely by a single source like a book, demand has increased for at least an overview of the current state of its notation. This page is trying to answer this demand by briefly introducing/describing every notational element as well as their translation into C# source code. Take this as a cheat sheet to put next to your whiteboard when designing software. However, please do not expect any explanation as to the reasons behind Flow-Design elements. Details on why Flow-Design at all and why in this specific way you´ll find in the literature covering the topic. Here´s a resource page on Flow-Design/Event-Based Components, if you´re able to read German. Notation Connected Functional Units The basic element of any FOD are functional units (FU): Think of FUs as some kind of software code block processing data. For the moment forget about classes, methods, “components”, assemblies or whatever. See a FU as an abstract piece of code. Software then consists of just collaborating FUs. I´m using circles/ellipses to draw FUs. But if you like, use rectangles. Whatever suites your whiteboard needs best.   The purpose of FUs is to process input and produce output. FUs are transformational. However, FUs are not called and do not call other FUs. There is no dependency between FUs. Data just flows into a FU (input) and out of it (output). From where and where to is of no concern to a FU.   This way FUs can be concatenated in arbitrary ways:   Each FU can accept input from many sources and produce output for many sinks:   Flows Connected FUs form a flow with a start and an end. Data is entering a flow at a source, and it´s leaving it through a sink. Think of sources and sinks as special FUs which conntect wires to the environment of a network of FUs.   Wiring Details Data is flowing into/out of FUs through wires. This is to allude to electrical engineering which since long has been working with composable parts. Wires are attached to FUs usings pins. They are the entry/exit points for the data flowing along the wires. Input-/output pins currently need not be drawn explicitly. This is to keep designing on a whiteboard simple and quick.   Data flowing is of some type, so wires have a type attached to them. And pins have names. If there is only one input pin and output pin on a FU, though, you don´t need to mention them. The default is Process for a single input pin, and Result for a single output pin. But you´re free to give even single pins different names.   There is a shortcut in use to address a certain pin on a destination FU:   The type of the wire is put in parantheses for two reasons. 1. This way a “no-type” wire can be easily denoted, 2. this is a natural way to describe tuples of data.   To describe how much data is flowing, a star can be put next to the wire type:   Nesting – Boards and Parts If more than 5 to 10 FUs need to be put in a flow a FD starts to become hard to understand. To keep diagrams clutter free they can be nested. You can turn any FU into a flow: This leads to Flow-Designs with different levels of abstraction. A in the above illustration is a high level functional unit, A.1 and A.2 are lower level functional units. One of the purposes of Flow-Design is to be able to describe systems on different levels of abstraction and thus make it easier to understand them. Humans use abstraction/decomposition to get a grip on complexity. Flow-Design strives to support this and make levels of abstraction first class citizens for programming. You can read the above illustration like this: Functional units A.1 and A.2 detail what A is supposed to do. The whole of A´s responsibility is decomposed into smaller responsibilities A.1 and A.2. FU A thus does not do anything itself anymore! All A is responsible for is actually accomplished by the collaboration between A.1 and A.2. Since A now is not doing anything anymore except containing A.1 and A.2 functional units are devided into two categories: boards and parts. Boards are just containing other functional units; their sole responsibility is to wire them up. A is a board. Boards thus depend on the functional units nested within them. This dependency is not of a functional nature, though. Boards are not dependent on services provided by nested functional units. They are just concerned with their interface to be able to plug them together. Parts are the workhorses of flows. They contain the real domain logic. They actually transform input into output. However, they do not depend on other functional units. Please note the usage of source and sink in boards. They correspond to input-pins and output-pins of the board.   Implicit Dependencies Nesting functional units leads to a dependency tree. Boards depend on nested functional units, they are the inner nodes of the tree. Parts are independent, they are the leafs: Even though dependencies are the bane of software development, Flow-Design does not usually draw these dependencies. They are implicitly created by visually nesting functional units. And they are harmless. Boards are so simple in their functionality, they are little affected by changes in functional units they are depending on. But functional units are implicitly dependent on more than nested functional units. They are also dependent on the data types of the wires attached to them: This is also natural and thus does not need to be made explicit. And it pertains mainly to parts being dependent. Since boards don´t do anything with regard to a problem domain, they don´t care much about data types. Their infrastructural purpose just needs types of input/output-pins to match.   Explicit Dependencies You could say, Flow-Orientation is about tackling complexity at its root cause: that´s dependencies. “Natural” dependencies are depicted naturally, i.e. implicitly. And whereever possible dependencies are not even created. Functional units don´t know their collaborators within a flow. This is core to Flow-Orientation. That makes for high composability of functional units. A part is as independent of other functional units as a motor is from the rest of the car. And a board is as dependend on nested functional units as a motor is on a spark plug or a crank shaft. With Flow-Design software development moves closer to how hardware is constructed. Implicit dependencies are not enough, though. Sometimes explicit dependencies make designs easier – as counterintuitive this might sound. So FD notation needs a ways to denote explicit dependencies: Data flows along wires. But data does not flow along dependency relations. Instead dependency relations represent service calls. Functional unit C is depending on/calling services on functional unit S. If you want to be more specific, name the services next to the dependency relation: Although you should try to stay clear of explicit dependencies, they are fundamentally ok. See them as a way to add another dimension to a flow. Usually the functionality of the independent FU (“Customer repository” above) is orthogonal to the domain of the flow it is referenced by. If you like emphasize this by using different shapes for dependent and independent FUs like above. Such dependencies can be used to link in resources like databases or shared in-memory state. FUs can not only produce output but also can have side effects. A common pattern for using such explizit dependencies is to hook a GUI into a flow as the source and/or the sink of data: Which can be shortened to: Treat FUs others depend on as boards (with a special non-FD API the dependent part is connected to), but do not embed them in a flow in the diagram they are depended upon.   Attributes of Functional Units Creation and usage of functional units can be modified with attributes. So far the following have shown to be helpful: Singleton: FUs are by default multitons. FUs in the same of different flows with the same name refer to the same functionality, but to different instances. Think of functional units as objects that get instanciated anew whereever they appear in a design. Sometimes though it´s helpful to reuse the same instance of a functional unit; this is always due to valuable state it holds. Signify this by annotating the FU with a “(S)”. Multiton: FUs on which others depend are singletons by default. This is, because they usually are introduced where shared state comes into play. If you want to change them to be a singletons mark them with a “(M)”. Configurable: Some parts need to be configured before the can do they work in a flow. Annotate them with a “(C)” to have them initialized before any data items to be processed by them arrive. Do not assume any order in which FUs are configured. How such configuration is happening is an implementation detail. Entry point: In each design there needs to be a single part where “it all starts”. That´s the entry point for all processing. It´s like Program.Main() in C# programs. Mark the entry point part with an “(E)”. Quite often this will be the GUI part. How the entry point is started is an implementation detail. Just consider it the first FU to start do its job.   Patterns / Standard Parts If more than a single wire is attached to an output-pin that´s called a split (or fork). The same data is flowing on all of the wires. Remember: Flow-Designs are synchronous by default. So a split does not mean data is processed in parallel afterwards. Processing still happens synchronously and thus one branch after another. Do not assume any specific order of the processing on the different branches after the split.   It is common to do a split and let only parts of the original data flow on through the branches. This effectively means a map is needed after a split. This map can be implicit or explicit.   Although FUs can have multiple input-pins it is preferrable in most cases to combine input data from different branches using an explicit join: The default output of a join is a tuple of its input values. The default behavior of a join is to output a value whenever a new input is received. However, to produce its first output a join needs an input for all its input-pins. Other join behaviors can be: reset all inputs after an output only produce output if data arrives on certain input-pins

    Read the article

  • What does Active, Targetset, and Active targetset mean in the Output of dfsutil /pkiinfo?

    - by Kyle Brandt
    I could use some guidance in interpreting the output of dfsutil /pktinfo. Using the following example: PS C:\Users\kbrandt dfsutil.exe /pktinfo ... Entry: \long.biz.foo\Images ShortEntry: \long.biz.foo\Images Expires in 4 seconds UseCount: 1 Type:0x81 ( REFERRAL_SVC DFS ) 0:[\OR-UTIL01\Images] ( TARGETSET ) 1:[\NY-FS01\Images] AccessStatus: 0xc00000be ( TARGETSET ) 2:[\NY-UTIL01\Images] AccessStatus: 0 ( ACTIVE ) Entry: \NY-UTIL01\Images ShortEntry: \NY-UTIL01\Images Expires in 65 seconds UseCount: 0 Type:0x81 ( REFERRAL_SVC DFS ) 0:[\or-util01\Images] ( TARGETSET ) 1:[\NY-FS01\Images] AccessStatus: 0xc00000be ( TARGETSET ) 2:[\NY-UTIL01\Images] AccessStatus: 0 ( ACTIVE ) Entry: \or-util01\Images ShortEntry: \or-util01\Images Expires in 0 seconds UseCount: 0 Type:0x81 ( REFERRAL_SVC DFS ) 0:[\OR-UTIL01\Images] AccessStatus: 0 ( ACTIVE TARGETSET ) 1:[\NY-UTIL01\Images] ( TARGETSET ) 2:[\NY-FS01\Images] Entry: \FOO\Images ShortEntry: \FOO\Images Expires in 108 seconds UseCount: 0 Type:0x81 ( REFERRAL_SVC DFS ) 0:[\OR-UTIL01\Images] AccessStatus: 0 ( ACTIVE TARGETSET ) 1:[\NY-UTIL01\Images] ( TARGETSET ) 2:[\NY-FS01\Images] What do the three states TARGETSET, ACTIVE TARGETSET, and ACTIVE mean exactly? In particular, why might OR-UTIL01 be ACTIVE for \long.biz.foo\Images but the shortname version FOO\Images have NY-UTIL01 as ACTIVE TARGETSET? I'd like to have a better understanding of this to know if it is normal or not. Once I understand it, I might be looking at and issue with IPv6 being disabled (http://support.microsoft.com/kb/2003961) if this isn't normal.

    Read the article

  • How do I hide "Extra File" and "100%" lines from robocopy output?

    - by Danny Tuppeny
    I have a robocopy script to back up our Kiln repositories that runs nightly, which looks something like this: robocopy "$liveRepoLocation" "$cloneRepoLocation" /MIR /MT /W:3 /R:100 /LOG:"$backupLogLocation\BackupKiln.txt" /NFL /NDL /NP In the output, there are a ton of lines that contain "Extra file"s, like this: *EXTRA File 153 E:\Kiln Backup\elasticsearch\data\elasticsearch-kiln\nodes\0\indices\kiln-2\0\index\_yxe.fdt *EXTRA File 12 E:\Kiln Backup\elasticsearch\data\elasticsearch-kiln\nodes\0\indices\kiln-2\0\index\_yxe.fdx *EXTRA File 128 E:\Kiln Backup\elasticsearch\data\elasticsearch-kiln\nodes\0\indices\kiln-2\0\index\_yxe.fnm *EXTRA File 363 E:\Kiln Backup\elasticsearch\data\elasticsearch-kiln\nodes\0\indices\kiln-2\0\index\_yxe.frq *EXTRA File 13 E:\Kiln Backup\elasticsearch\data\elasticsearch-kiln\nodes\0\indices\kiln-2\0\index\_yxe.nrm Additionally, there are then hundreds of lines at the bottom that contain nothing but "100%"s, like this: 100% 100% 100% 100% 100% 100% 100% In addition to making the log files enormous (there are a lot of folders/files in Kiln repos), it makes it annoying to scan through the logs now and then to see if everything was working ok. How do I stop "Extra Files" appearing in the log? How do I stop these silly "100%" lines appearing in the log? I've tried every combination of switch I can think of (the current switches are listed above in the command), but neither seem to hide these!

    Read the article

  • Why Does My Website Redirect me to my localhost?

    - by Noah Brainey
    Alight, my website has some issues that I'm not sure what's causing them. Visit this page http://online-file-sharing.net/tos.html and click one of the bottom footer links... it redirects you to your localhost in the address bar. I have no idea why it does this. I'm hosting this website on my own server, which is this computer, and using Xampp. If this information helps. Anyways any help would be greatly appreciated! I'm also using DYNDNS as my nameservers.

    Read the article

  • How can I rewrite / redirect URL's in Glassfish V3?

    - by Jin Liew
    Hi, I'd like to simplify the URL's to access a Glassfish V3 application by removing file extensions and otherwise shortening URL's. I've already set my application as the default application, so that there is no need to include the context root in the URL. I'd like to: * Remove file extensions * Shorten the URL to files deep in the folder structure I'd like to do this using pattern matching rather than on a per file basis (Site is small at the moment but will change frequently and grow). Some examples of what I'd like to do: * foo.com/bar.html - foo.com/bar * foo.com/folder1/folder2/bar2.html - foo.com/bar2 Any help would be greatly appreciated. Thanks. Cheers, Jin

    Read the article

  • Centos IPTables configuration for external firewall

    - by user137974
    Current setup Centos which is a Web, Mail (Postfix,Dovecot), FTP Server and Gateway with public ip and private ip (for LAN Gateway). We are planning to implement external firewall box and bring the server to LAN Please guide on configuring IPTables... Unable to receive mail and outgoing mail stays in postfix queue and is sent after delaying... The local ip of the server is 192.168.1.220 iptables -P INPUT DROP iptables -P FORWARD DROP iptables -P OUTPUT DROP incoming HTTP iptables -A INPUT -i eth0 -p tcp --dport 80 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --sport 80 -m state --state ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --dport 443 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --sport 443 -m state --state ESTABLISHED -j ACCEPT outgoing HTTP iptables -A OUTPUT -o eth0 -p tcp --dport 80 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --sport 80 -m state --state ESTABLISHED -j ACCEPT FTP iptables -A INPUT -p tcp -s 0/0 --sport 1024:65535 -d 192.168.1.220 --dport 21 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -p tcp -s 192.168.1.220 --sport 21 -d 0/0 --dport 1024:65535 -m state --state ESTABLISHED -j ACCEPT iptables -A INPUT -p tcp -s 0/0 --sport 1024:65535 -d 192.168.1.220 --dport 1024:65535 -m state --state ESTABLISHED,RELATED -j ACCEPT iptables -A OUTPUT -p tcp -s 192.168.1.220 --sport 1024:65535 -d 0/0 --dport 1024:65535 -m state --state ESTABLISHED -j ACCEPT SMTP iptables -A INPUT -p tcp -s 0/0 --sport 1024:65535 -d 192.168.1.220 --dport 25 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -p tcp -s 192.168.1.220 --sport 25 -d 0/0 --dport 1024:65535 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -p tcp -s 192.168.1.220 --sport 1024:65535 -d 0/0 --dport 25 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -p tcp -s 0/0 --sport 25 -d 192.168.1.220 --dport 1024:65535 -m state --state ESTABLISHED -j ACCEPT POP3 iptables -A INPUT -p tcp -s 0/0 --sport 1024:65535 -d 192.168.1.220 --dport 110 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -p tcp -s 192.168.1.220 --sport 110 -d 0/0 --dport 1024:65535 -m state --state ESTABLISHED -j ACCEPT

    Read the article

  • Apache reverse proxy: no protocol handler

    - by gonvaled
    I am trying to configure a reverse proxy with apache, but I am getting a No protocol handler was valid for the URL error, which I do not understand. This is the relevant configuration of apache: ProxyRequests Off ProxyPreserveHost On <Proxy *> Order deny,allow Allow from all </Proxy> ProxyPass /gonvaled/examples/jsonrpc/output/services/ http://localhost:8000/services/ ProxyPassReverse /gonvaled/examples/jsonrpc/output/services/ http://localhost:8000/services/ The requests is reaching apache as: POST /gonvaled/examples/jsonrpc/output/services/EchoService.py HTTP/1.1 And they should be forwarded to my internal service, located at: 0.0.0.0:8000/services/EchoService.py These are the logs: ==> /var/log/apache2/error.log <== [Wed Jun 20 02:05:20 2012] [debug] proxy_util.c(1506): [client 127.0.0.1] proxy: http: found worker http://localhost:8000/services/ for http://localhost:8000/services/EchoService.py, referer: http://localhost/gonvaled/examples/jsonrpc/output/JSONRPCExample.safari.cache.html [Wed Jun 20 02:05:20 2012] [debug] mod_proxy.c(998): Running scheme http handler (attempt 0) [Wed Jun 20 02:05:20 2012] [warn] proxy: No protocol handler was valid for the URL /gonvaled/examples/jsonrpc/output/services/EchoService.py. If you are using a DSO version of mod_proxy, make sure the proxy submodules are included in the configuration using LoadModule. [Wed Jun 20 02:05:20 2012] [debug] mod_deflate.c(615): [client 127.0.0.1] Zlib: Compressed 614 to 373 : URL /gonvaled/examples/jsonrpc/output/services/EchoService.py, referer: http://localhost/gonvaled/examples/jsonrpc/output/JSONRPCExample.safari.cache.html ==> /var/log/apache2/access.log <== 127.0.0.1 - - [20/Jun/2012:02:05:20 +0200] "POST /gonvaled/examples/jsonrpc/output/services/EchoService.py HTTP/1.1" 500 598 "http://localhost/gonvaled/examples/jsonrpc/output/JSONRPCExample.safari.cache.html" "Mozilla/5.0 (X11; Linux i686) AppleWebKit/535.19 (KHTML, like Gecko) Chrome/18.0.1025.162 Safari/535.19"

    Read the article

  • I am using apache mod rewrie to redirect http to https but now cannot connect to localhost/phpmyadmin

    - by user1787331
    here is my /etc/apache2/sites-enabled/000-default <VirtualHost *:80> ServerAdmin [email protected] RewriteEngine On RewriteCond %{HTTPS} off RewriteRule (.*) https://mysite.com DocumentRoot /var/www/http <Directory /> Options None AllowOverride None </Directory> <Directory /var/www/http> Options -Indexes -FollowSymLinks MultiViews AllowOverride None Order allow,deny allow from all </Directory> ScriptAlias /cgi-bin/ /usr/lib/cgi-bin/ <Directory "/usr/lib/cgi-bin"> AllowOverride None Options +ExecCGI -MultiViews +SymLinksIfOwnerMatch Order allow,deny Allow from all </Directory> ErrorLog ${APACHE_LOG_DIR}/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn CustomLog ${APACHE_LOG_DIR}/access.log combined Alias /doc/ "/usr/share/doc/" <Directory "/usr/share/doc/"> Options Indexes MultiViews FollowSymLinks AllowOverride None Order deny,allow Deny from all Allow from 127.0.0.0/255.0.0.0 ::1/128 </Directory> </VirtualHost> Not sure how to fix this. Any thoughts?

    Read the article

  • How can I rewrite / redirect URL's in Glassfish V3?

    - by Jin Liew
    I'd like to simplify the URL's to access a Glassfish V3 application by removing file extensions and otherwise shortening URL's. I've already set my application as the default application, so that there is no need to include the context root in the URL. I'd like to: * Remove file extensions * Shorten the URL to files deep in the folder structure I'd like to do this using pattern matching rather than on a per file basis (Site is small at the moment but will change frequently and grow). Some examples of what I'd like to do: * foo.com/bar.html - foo.com/bar * foo.com/folder1/folder2/bar2.html - foo.com/bar2 Any help would be greatly appreciated. Thanks. Cheers, Jin

    Read the article

  • Video output vanishes and it isn't the video card... suggestions?

    - by Ira Baxter
    I have a high-end dual processor Dell workstation that operated for several years without problem. Recently, the video output has gone flaky, in the sense that after 2-3 days, it loses synch with the monitor (sometimes you can still see a hashed-mess of the what you expect to see on the screen). Poking at the keyboard, and accessing the file system on the machine from over the network, indicates that the machine is running fine and its just the video. A reboot fixes the problem... for another day or two. This in effect makes the machine unusable. So, I replaced the video card with an exact duplicate bought from e-bay. (I checked after the dupe arrived to be sure, yep, same model number). I still get the same behavior. So unless I believe that both video cards are broken the same way, I have to beleive this is a problem with the motherboard/power supply, neither of which I am inclined to replace. The only other possibility I can think of is a Windows update to the graphics driver. How would I check for this? Anybody had a similar problem? Otherwise we're junking what used to be a perfectly good machine. (Another couple of hours of more wasted effort and that's it in terms of economics anyway).

    Read the article

  • Redirect or send mail in a script that runs in a rule on incoming mails in outlook 2010

    - by Guido Mertens
    I have the following problem: - I have a mails that are arriving in my mailbox - these mails contain a specific string in the body - what I want to do is: -- removing this string from the body -- then send this body to another mail adres (send, not forward) What have I already done: A. created a rule that activates the script in incoming messages that contain a certain string in the description This is the rule description: Apply to message with "Maileater" in the subject and on this computer only run "Project1.ChangeString" B. created the script with the following instructions: Public Sub ChangeString(MyMail As MailItem) Dim body As String body = MyMail.body body = Replace (body, "=====================================================", " ") MyMail.body = body MyMail.Save End Sub C. now I want to add in the script the instruction to send the body (or MyMail.body) to a specific mail adres (e.g. [email protected] with description "Support asked") after the replace of the string. is this possible? Can someone help me with this, I would be very greatfull because this will eliminate me from a lot of manual work. remark: this is just an exemple of a mail, the real thing will contain other replacements and mails to send

    Read the article

  • Why won't my service start, and why doesn't upstart output any errors?

    - by Alex Waters
    I am trying to 'start gunicorn' as a service via upstart as user ale. I'm using gunicorn/flask on ubuntu 12.04 w/ init (upstart 1.5) Here is my /etc/init/gunicorn.conf setuid btw setgid flask script export HOME=/home/btw export WORKON_HOME=$HOME/.virtualenvs . $HOME/.virtualenvs/default/bin/activate cd $HOME/flask workon default gunicorn -c gunicorn.py bw:app end script It doesn't output anything other than gunicorn start/running, process 12992. If i then do 'status gunicorn' I get stop/waiting. any ideas on how to debug this? I tried following http://upstart.ubuntu.com/wiki/Debugging but it didn't help. If I do the following as user ale in the app's directory: 1. workon default 2. gunicorn -c gunicorn.py bw:app then Gunicorn runs fine. Here is ~/flask/gunicorn.py: bind = "0.0.0.0:8080" workers = 3 backlog = 2048 worker_class = "gevent" debug = True daemon = False pidfile ="/tmp/gunicorn.pid" log_level = "debug" accesslog = "/var/log/gunicorn/access.log" errorlog = "/var/log/gunicorn/error.log" user = "btw" group = "flask" Also, /var/log/error.log doesn't show anything new when I try to start the Gunicorn service. If I start it manually, it shows that the workers have been loaded, etc. Thanks for any help / suggestions!

    Read the article

  • What's the best way to do user profile/folder redirect/home directory archiving?

    - by tpederson
    My company is in dire need of a redesign around how we handle user account administration. I've been tasked with automating the process. The end goal is to have the whole works triggered by the business, and IT only looking in when there's an error reported. The interim phase is going to be semi-manual. That is a level 2 tech inputs the user's info and supervises the process. The current hurdle I'm facing is user profile archiving. Our security team requires us to archive the profile directories for any terminated user for 60 days in case the legal team requires access to their files. Our AD is as much a mess as everything else, so there are some users with home directories and some with profiles. Anyone who has a profile dir in AD also has a good deal of their profile redirected to our file servers over DFS. In order to complete the process manually you find the user in AD, disable them, find their home/profile dir, go there and take ownership, create an archive folder, move all their files over, then delete the old dir. Some users have many many gigs of nonsense and this can take quite some time. Even automated the process would not be a quick one. I'm thinking that I need to have a client side C# GUI for the quick stuff and some server side batch script or console app to offload this long running process. I have a batch script that works decently using takeown and robocopy, but I wonder if a C# console app would do a better job. So, my question at long last is, what do you think is the best way to handle this? I can't imagine this is a unique problem, how do other admins get this done? The last place I worked was easily 10x larger than the place I'm in now. If we would have been doing this manual crap there, they'd have needed a team of at least 30 full time workers to keep up. I have decent skills in C#.net and batch scripting, but am a quick study and I have used most every language once or twice. Thank you for reading this and I look forward to seeing what imaginative solutions you all can come up with.

    Read the article

  • Problems with 5.1 digital out on Ubuntu 12.04

    - by user895319
    I've recently bought a new PC, installed Ubuntu and am now unable to get 5.1 digital sound working. Simple analogue stereo works fine on both the front and rear connectors. On my old box I connected the coax connection from my soundcard to my surround sound amplifier, set Settings-Sound to "Digital Stereo Duplex" and it worked. My old soundcard doesn't fit in my new machine so I'm using the built-in sound hardware. I'm connecting the combination output socket on the back of the PC via the same cable to my surround amp as before. The MB is an MSI Global H61M-P31 with an RealTek ALC887 sound chip. When I go to Settings-Sound I only see "Headphone Built-in Audio" and "Analogue Output Built-in Audio" - no digitial options. The output from aplay -l is: default Playback/recording through the PulseAudio sound server sysdefault:CARD=PCH HDA Intel PCH, ALC887-VD Analog Default Audio Device front:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog Front speakers surround40:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog 4.0 Surround output to Front and Rear speakers surround41:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog 5.1 Surround output to Front, Center, Rear and Subwoofer speakers surround71:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog 7.1 Surround output to Front, Center, Side, Rear and Woofer speakers dmix:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog Direct sample mixing device dsnoop:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog Direct sample snooping device hw:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog Direct hardware device without any conversions plughw:CARD=PCH,DEV=0 HDA Intel PCH, ALC887-VD Analog Hardware device with all software conversions While googling for ALC887 I've seen some references to "ALC887 -VD Analog" and some to "ALC887 -VD Digital". Does anyone know if I need to force it to chance mode somehow? It's worth mentioning that when I set the output to 5.1 digital surround in Windows 7 on the same machine I still don't get any sound so it's not a unique Linux problem. Thanks for any help.

    Read the article

  • Can I connect a Playstation 3's HDMI output to my monitor's DVI-D input? [migrated]

    - by HankJDoomstorm
    I'm attempting to connect my Playstation 3 to my computer monitor. The monitor has a DVI-D (dual link) input, so before distinguishing between the different DVI varieties, I bought a DVI-I (dual link) to HDMI converter that won't fit into the port on the monitor (not only that, there isn't enough physical space in the back of the monitor to fit that much stuff before it hits the bottom of it). So I grabbed a DVI-D (single link) cable and got a female-to-female DVI-I coupler, and plugged the DVI-D cable into the monitor and the whole mess of converters. The end result was HDMI to DVI-D single link, but my monitor isn't receiving a signal on its digital channel. (For clarity's sake: DVI-D DL input on Monitor, DVI-D SL cable, DVI-I DL female-to-female coupler, DVI-I DL to HDMI converter, HDMI output on PS3) I don't know much about this stuff (obviously), but my educated guess is that the bandwidth of the PS3 is too high for the DVI-D Single Link cable, so nothing's getting through. Will replacing the single link cable with dual link resolve this? If not, is it possible at all? Oh, I should mention I'm aware I won't get audio through the monitor. I have an RCA to 3.5mm converter for that.

    Read the article

  • How can I make sound over hdmi in kubuntu work?

    - by user32509
    I have used a hdmi cable to connect my lcd (which is connected with my speakers) with my nvida 275 gtx grafic card. I can not get the sound output to work. The hardware itself is working probably - I tested it under windows. Currently I am running Kubuntu 9.10 64 with Nvidia 190.53. The sound output worked fine before I installed the hdmi connection. (German output - i can change it, if you tell me how :)) aplay -l **** Liste von PLAYBACK Geräten **** Karte 0: Intel [HDA Intel], Gerät 0: ALC889A Analog [ALC889A Analog] Untergeordnete Geräte: 1/1 Untergeordnetes Gerät '0: subdevice #0 Karte 0: Intel [HDA Intel], Gerät 1: ALC889A Digital [ALC889A Digital] Untergeordnete Geräte: 1/1 Untergeordnetes Gerät '0: subdevice #0 aplay -L front:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog Front speakers surround40:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 4.0 Surround output to Front and Rear speakers surround41:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 5.1 Surround output to Front, Center, Rear and Subwoofer speakers surround71:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 7.1 Surround output to Front, Center, Side, Rear and Woofer speakers iec958:CARD=Intel,DEV=0 HDA Intel, ALC889A Digital IEC958 (S/PDIF) Digital Audio Output null Discard all samples (playback) or generate zero samples (capture) pulse Playback/recording through the PulseAudio sound server And i disabled mute in kmix an all channels :)

    Read the article

  • mod-rewrite: what's wrong with this simple rewrite to redirect to a subdirectory?

    - by Tom Auger
    the root directory http: // www .mydomain .com (SF won't let me post hyperlinks - rep is too low) has a catchall index.php page in it, and an .htaccess file. Within this root directoy I have a wordpress/ directory which contains (suprise surprise) a wordpress installation. My goal is that when the user types in http: // www .mydomain .com they are instead taken to http: // www .mydomain .com/wordpress Here is my rewrite rule: RewriteEngine on RewriteCond %{REQUEST_URI} !^/wordpress RewriteRule ^/(.*)$ http://%{SERVER_NAME}/wordpress/$1 [L] At the moment it appears to do nothing - it still loads index.php within the root directory. What should my rewrite rule be (I'm assuming the one I'm using is wrong)?

    Read the article

  • Can I tell Chrome not to redirect mistyped URLs?

    - by Nathan Long
    If I mistype a URL, Chrome sometimes redirects me to a search. For instance, typing "example_url_i_sometimes_mistype.conm" into the location bar gets me: Your search - example_url_i_sometimes_mistype.conm - did not match any documents. Not only is this annoying, but if the mistyped URL was one on private DNS, I've now just told Google that the domain exists. (A small concern, but bad in principle.) Can I configure Chrome to just show an error and not blab to Google Search about it?

    Read the article

< Previous Page | 132 133 134 135 136 137 138 139 140 141 142 143  | Next Page >