Search Results

Search found 16034 results on 642 pages for 'context switch'.

Page 137/642 | < Previous Page | 133 134 135 136 137 138 139 140 141 142 143 144  | Next Page >

  • nginx and proxy_hide_header

    - by giskard
    When I curl for a URL I get this answer back: > < HTTP/1.1 200 OK < Server: nginx/0.7.65 < Date: Thu, 04 Mar 2010 12:18:27 GMT < Content-Type: application/json < Connection: close < Expires: Thu, 04 Mar 2010 12:18:27 UTC < http.context.path: /1/ < jersey.response: com.sun.jersey.spi.container.ContainerResponse@17646d60 < http.custom.headers: {Content-Type=text/plain} < http.request.path: /2/messages/latest.json < http.status: 200 < Transfer-Encoding: chunked I want to remove < http.context.path: /1/ < jersey.response: com.sun.jersey.spi.container.ContainerResponse@17646d60 < http.custom.headers: {Content-Type=text/plain} < http.request.path: /2/messages/latest.json < http.status: 200 So I used the proxy_hide_header directive in this way: location / { if ($arg_id) { proxy_pass http..authorized; break; } proxy_pass http..anonymous; proxy_hide_header http.context.path; proxy_hide_header jersey.response; proxy_hide_header http.request.path; proxy_hide_header http.status ; } But it doesn't work. any clues?

    Read the article

  • Server 2012, Jumbo Frames - should I expect problems?

    - by TomTom
    Ok, this sound might stupid - but is there any negative on just enabling jumbo frames in practice? From what I understand: Any switch or ethernet adapter that sees a jumbo frame it can not handle will just drop it. TCP is not a problem as max frame size is negotiated in the setinuo phase. UCP is a theoretical problem as a server may just send a LARGE UDP packet that gets dropped on the way. Practically though, as UDP is packet based, I do not really think any software WOULD send a UDP packet larger than 1500 bytes net without app level configuration changes - at least this is how I do my programming, as it is quite hard to get a decent MTU size for that without testing yourself, so you fall back in programming to max 1500 packets. The network in question is a standard small business network - we upgraded now from a non managed 24 port switch to a 52 port switch with 4 10g ports (netgear - quite cheap) and will mov a file server to 10g for also ISCSI serving. All my equipment on the Ethernet level can handle minimum 9000 bytes and due to local firewalls I really want to get packets larger (less firewall processing), but the network is also NAT'ed to the internet. On top, different machines move around (download) large files (multi gigabyte area) quite often for processing. The question is - can I expect problems when I just enable jumbo frames? Again, this is not totally ignorance - I just don't see programs sending more than 1500 byte UDP packets (if that is a practical problem please tell me) and for TCP the MTU is negotiated anyway. if there is a problem I can move to a dedicated VLAN, but this has it's own shares of problems as basically most workstations must then be on both VLAN's.

    Read the article

  • Bridging my laptop's wireless and wired adaptors

    - by stacey.richards
    I would like to be able to connect a desktop computer that does not have a wireless adapter to my wireless network. I could just run a network cable from my ADSL/wireless router to the desktop computer but sometimes this is not practical. What I would really like to do is bridge my laptop's wireless and wired adapters in such a way that I can run a network cable from my laptop to a switch and another network cable from the switch to a desktop computer so that the desktop computer can access the Internet through my ADSL/wireless router via my latop: +--------------------+ |ADSL/wireless router| +--------------------+ | +-------------------------+ |laptop's wireless adaptor| | | |laptop's wired adaptor | +-------------------------+ | +------+ |switch| +------+ | +-----------------------+ |desktop's wired adapter| +-----------------------+ A bit of Googling suggests that I can do this by bridging my laptop's wireless and wired adapters. In Windows XP's Network Connections I select both the Local Area Connection and the Wireless Network Connection, right click and select Bridge Connections. From what I gather, this (layer 2?) bridge will examine the MAC address of traffic coming from the wireless network and pass it through to the wired network if it suspects that a network adapter with that MAC address may be on the wired side, and vice-versa. If this is the case, I would assume that when the desktop computer attempts to get an IP address from a DHCP server (which is running on the ADSL/wireless router), it would send a DHCP broadcast packet which would pass through the laptop's bridge to the router and the reply would return through the laptop's bridge back to the desktop. This doesn't happen. With some more Googling I find some instruction how this can be done with Linux. I reboot to Ubuntu 9.10 and type the following: sudo apt-get install bridge-utils sudo brctl addbr br0 sudo brctl addif br0 wlan0 sudo brctl addif br0 eth0 sudo ipconfig wlan0 0.0.0.0 sudo ipconfig eth0 0.0.0.0 Once again, the desktop cannot reach the ADSL/wireless router. I suspect that I'm missing some simple important step. Can anyone shed some light on this for me?

    Read the article

  • Restricting Access to Application(s) on Point of Sale system

    - by BSchlinker
    I have a customer with two point of sale systems, a few workstations and a Windows 2003 SBS Server. The point of sale systems are typically running QuickBooks Point of Sale and are logged in with a user who has restricted permissions / access (via Group Policy). Occasionally, one of the managers needs to be able to run a few additional applications -- including some accounting software. I have created an additional user for this manager, allowing them to login and access the accounting software. The problem is, it can be problematic to switch users on the system, as QuickBooks takes a few minutes to close (on POSUser) and then reopen (on ManagerUser). If customers are waiting, this slows things down drastically. Since the accounting software is stored on a network drive, it would be easiest if the manager could simply double click something, authenticate against the network drive / domain controller and then the program would launch. When they close the program, the session to the network drive would be lost and the program would no longer be accessible. Is there any easy way to do this? Both users are on a domain and the system is Windows 7. I just don't want to require the user to switch back and forth. In a worst case scenario, they forget to switch back and leave the accounting software wide open.

    Read the article

  • FWBuilder DNS Object Run Time - when exactly does it resolve the DNS name?

    - by Jakobud
    In Firewall Builder, when you use the DNS Object and set it to run time, when exactly does the firewall (iptables in our case) actually resolve the DNS name? Is it whenever a call is made to that DNS name in the firewall? So the firewall would resolve the name on the fly whenever someone/something tries to access that DNS name? Or is it when you execute the fw script to load the rules into iptables? So in this case, it would resolve the DNS name that one time and then hard-code the resulting ip address into the iptable rules? From what I read, I think its #1, but it's just not 100% clear to me. We have two servers for a certain function on our network. One is the primary server and one is backup. alpha0.domain.com alpha1.domain.com In DNS we have this: alpha.domain.com -> alpha0.domain.com If the primary server goes down and we need to switch to the backup, I just change our local DNS record to point to alpha1.domain.com instead. So back to the firewall, if I just put in a Domain Object as alpha.domain.com, do I have to reload the firewall rules every time we switch to the backup alpha server and change the DNS record? Or will the firewall automatically resolve to the correct address even after the switch?

    Read the article

  • 10GE network: Is it still deadly expensive? Any options?

    - by BarsMonster
    Hi! I am building home cluster where I going to have about 16 nodes which can live with 1G ports, but I really want to have 10GE on file server & central node. It's all local, so no need for cabels longer than 3-5m. And ofcourse I want to spend as little money as possible (not going to spend more than whole cluster costs) :-) What are my options? 1) Legacy solution is to take some 24-48 port 1GE switch, and connect to file/central nodes via 4-8 aggregated links. This will work I guess, cost is very acceptable, but I am not sure if it's ok to use that much aggregated links. And ofcourse it would be hard to double bandwidth when needed... :-D 2) Switch with several 10GE uplink 'ports'. As far as I see, they all require modules which costs about 1000$, so I will need 4 10G modules, and 2 10GE cards... Smells like way more than 5000$+... 3) Connect file & central node via 2 10G cards directly, and put 4 quadport 1GE NICs on fileserver. I am saving on 2 10G modules and a switch, fileserver will have to do packet routing, but it's still gonna have alot of CPU's left :-) 4) Any other options? Infiniband? 5) Are MyriNet adaptors works fine? I guess there are no cheaper options? 6) Hmm... Scrap fileserver, put it all on central node and provide dedicated 1GE port for each of the nodes... This is sad...

    Read the article

  • Network speed between a VM and another machine which is not residing on the same host, is 11MB/s at most

    - by Henno
    Problem Network speed between a VM and another machine which is not residing on the same host, is 11MB/s at most. Topology Facts ESXi5 version is 5.0.0.504890 VM has the latest Vmware Tools installed VM is using E1000 network driver Physical box has Win Srv 2008 R2 as the OS CrystalDiskMark says the drive on physical box can read/write 100MB/s vCenter is another vm on esx both vm and physical box are showing 1Gbps link speed Configuration Networking shows vmnic0 as 1000 Full NTttcp is a client/server tool from Microsoft for measuring pure network throughput Here's what I've done so far: Test1: VM is running Filezilla FTP Server (default settings, one user account made) Physical box is running Filezilla FTP Client (default settings) Physical box is uploading a big file to FTP server Transfer speed (as observed by Windows Task Manager on both machines): ~11MB/s (bad) Physical box is downloading that file from FTP server Transfer speed (as observed by Windows Task Manager on both machines): still ~11MB/s (bad) Could it be disk performance issue? Test2: Physical box is running ntttcpr.exe -a 6 -m 6,0,VM_IP_ADDRESS VM is running ntttcps.exe -a 6 -m 6,0,PHY_BOX_IP_ADDRESS Transfer speed (as observed by Windows Task Manager on both machines): ~11MB/s (bad) Could it be switch performance issue? Test3: physical box is running vSphere Client I open Summary Storage datastore Browse Datastore... from physical box and upload a file to datastore Transfer speed (as observed by Windows Task Manager on physical box): ~26-36MB/s (good) Could it be a vm specific issue? Test4: Installed ntttcp to another vm on the same esx server Measured network performance between vms on the same esx server with NTttcp Transfer speed (as observed by Windows Task Manager on physical box): ~90-120MB/s (excellent :) Test5: I have another esx server on the same site, connecting to the same datastore and same switch. Those two ESX servers have both 2 NICs. One NIC goes to switch while the other goes directly to the other ESX server. vMotioned one of the testing vms off to the other ESX host Measured network performance between vms on different esx servers with NTttcp Transfer speed (as observed by Windows Task Manager on physical box): ~11MB/s (bad) While I'm aware of these: ESXi 4.1 slow file transfer ESXi 5 network performance is slow Debian Etch and ESXi slow network speeds VMWare ESXi slow file copy to guest they did not help (or I must have been missed something)

    Read the article

  • Debian, 2 NICs load-balancing or agregating with one same gateway

    - by pouney
    Hi, I have one server, with double NICs connected to one switch with the same gateway. Behind the switch we have internet. |Debian| - eth0 - switch - internet - eth1 - same I don't understand how to load-balancing between eth0 and eth1. The inbound/outbound traffic always use eth1. This is the config: # The primary network interface allow-hotplug eth0 auto eth0 iface eth0 inet static address 192.168.248.82 netmask 255.255.255.240 network 192.168.248.80 broadcast 192.168.248.95 gateway 192.168.248.81 allow-hotplug eth1 auto eth1 iface eth1 inet static address 192.168.248.83 netmask 255.255.255.240 network 192.168.248.80 broadcast 192.168.248.95 gateway 192.168.248.81 Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 192.168.248.80 0.0.0.0 255.255.255.240 U 0 0 0 eth1 192.168.248.80 0.0.0.0 255.255.255.240 U 0 0 0 eth0 0.0.0.0 192.168.248.81 0.0.0.0 UG 0 0 0 eth1 0.0.0.0 192.168.248.81 0.0.0.0 UG 0 0 0 eth0 Ips aren't real, it's just for the example. Anybody have an idea on correct routing to use eth0 on 192.168.248.82 and eth1 on 192.168.248.83 ? I have many example for multiple gateway but here it's the same. Thanks all. Regards

    Read the article

  • VLAN for WiFi traffic separation (new to VLANing)

    - by Philip
    I run a school network with switches in different departments. All is routed through to a central switch to access the servers. I would like to install WiFi access points in the different departments and have this routed through the firewall (an Untangle box that can captive-portal the traffic, to provide authentication) before it gets onto the LAN or to the Internet. I know that the ports that the APs connect to on the relevant switches need to be set to a different VLAN. My question is how do I configure these ports. Which are tagged? Which are untagged? I obviously don't want to interrupt normal network traffic. Am I correct in saying: The majority of the ports should be UNTAGGED VLAN 1? Those that have WiFi APs attached should be UNTAGGED VLAN 2 (only) The uplinks to the central switch should be TAGGED VLAN 1 and TAGGED VLAN 2 The central switch's incoming ports from the outlying switches should also be TAGGED VLAN 1 and TAGGED VLAN 2 There will be two links to the firewall (each on its own NIC), one UNTAGGED VLAN 1 (for normal internet access traffic) and one UNTAGGED VLAN 2 (for captive portal authentication). This does mean that all wireless traffic will be routed over a single NIC which will also up the workload for the firewall. At this stage, I'm not concerned about that load.

    Read the article

  • Delayed internet access

    - by Joel Coel
    When I (and presumably my users) first start up or log in to my computer I can't get internet access until several minutes after logging in. Internet pages like serverfault.com will time out. During this time I can access internal web servers. Sometimes pinging the gateway seems to fix the problem. I'm using Windows 7 on this machine with wifi, and the problem seems limited to the wifi network, which is on a separate vlan. The wired network does not share the problem, but I know it's not the wifi connection itself because the internal sites work. The wifi access point is attached to a 3Com 4200 switch, with the port set for vlan 2 untagged, vlan 1 tagged. The 4200 has a fiber connection to a 3Com 4900SX fiber switch that acts almost as a router here. The fiber connection is vlan 1 untagged vlan 2 tagged at both ends. The gateway is then attached to a different 4200 (vlan 1 untagged, vlan 2 tagged) that has a similar fiber connection to the 4900SX. vlan 2 has 192.168.8.0/22 IPs, vlan 1 has 10.1.0.0/16 IPs. The 4900SX has an interface for both vlans (10.1.1.1/192.168.8.1), as does the gateway (10.1.1.5/192.168.8.5). There is one dchp server for both vlans on the same switch as the gateway. It chooses a dhcp scope based on the interface used by the 4900sx to forward the dhcp request. There is also a network access list on the 4900sx set to deny all vlan2 traffic to any 10.1.x.x host, with exceptions made for a few servers, including dhcp, 4900sx, and the gateway. I think that about covers it. Any ideas on why internet access would be delayed like this?

    Read the article

  • Procurve Primary VLAN

    - by fukawi2
    I'm trying to depreciate usage of VLAN 1 on my ProCurve switches; 1 is unused. I understand that VLAN 1 must exist, but I want to remove it from all ports, especially trunks between switches. The problem I have is that stacking does not seem to work without VLAN 1. I have changed the primary VLAN and management VLAN on all the switches: (config)# primary-vlan 42 (config)# management-vlan 42 (config)# no vlan 1 untagged 25 Port 25 is the link between the 2 switches I'm testing with; the stack master and a member switch; I only want tagged traffic between the switches, no untagged frames. show stacking on the master shows all members as "UP" but I can not telnet any of them: Telnet failed: Connection timed out. All switches have manually assigned (static) IP addresses on VLAN 42, and all exist in the same /25 subnet, as does my desktop. I can telnet the switches directly from my desktop to the individual switch IP addresses, just not from the master switch. Do I need to reboot the switches to have the primary-vlan change take effect? Or is there something else I'm missing?

    Read the article

  • What could cause these "failed to authenticate" logs other than failed login attempts (OSX)?

    - by Tom
    I've found this in the Console logs: 10/03/10 3:53:58 PM SecurityAgent[156] User info context values set for tom 10/03/10 3:53:58 PM authorizationhost[154] Failed to authenticate user (tDirStatus: -14090). 10/03/10 3:54:00 PM SecurityAgent[156] User info context values set for tom 10/03/10 3:54:00 PM authorizationhost[154] Failed to authenticate user (tDirStatus: -14090). 10/03/10 3:54:03 PM SecurityAgent[156] User info context values set for tom 10/03/10 3:54:03 PM authorizationhost[154] Failed to authenticate user (tDirStatus: -14090). There are about 11 of these "failed to authenticate" messages logged in quick succession. It looks to me like someone is sitting there trying to guess the password. However, when I tried to replicate this I get the same log messages except that this extra message appears after five attempts: 13/03/10 1:18:48 PM DirectoryService[11] Failed Authentication return is being delayed due to over five recent auth failures for username: tom. I don't want to accuse someone of trying to break into an account without being sure that they were actually trying to break in. My question is this: is it almost definitely someone guessing a password, or could the 11 "failed to authenticate" messages be caused by something else? EDIT: The actual user wasn't logged in, or using a computer at the time of the log in attempts.

    Read the article

  • Best way to troubleshoot intermittent network outages?

    - by Ben Scheirman
    We have a Comcast 50/10 line into our office. We keep seeing very short but sometimes frequent drops in our internet service. It's enough to kick you off of skype and stop any websites from loading, which is obviously affecting our productivity. We've tried 4 different routers, we've tried moving everyone off of wireless and onto wired via a switch and so far nothing has helped. Right now we're on a Cisco SB WRP400-G1 router. Attached to the router is a 16 port switch going to the ports in all of the offices. We've moved to OpenDNS in the case that it was the comcast DNS servers going down. Today we tried putting the modem, router, and switch on a UPS to make sure it wasn't power fluctuations that was causing it. Every time we call Comcast, by the time they are here the internet is working fine. I'd like to somehow prove that the problem is with Comcast, so if that means plugging in a machine directly into their router and collecting data all day, I'm up for that. I just want to hear ideas on what tools to run and how to collect this data. I could just continuously ping google.com all day long but I'm not sure how valuable that data would be. Thoughts?

    Read the article

  • XP box with 3 NICs on Server 2003 Domain

    - by Hannibal
    I have assigned all three NICs IP addresses that are outside the DHCP pool. I have 2 NICs are connected to 1 switch and the 3rd to my second switch. I want to assign one of the two NICs on the 1st switch to "normal" network activity (e.g. internet access, RDP, etc.) The other two NICs I want to reserve for mirroring ports on their respective switches. While this machine is connected to the domain I can access the internet and Remote Desktop. I have no idea which NIC I am using until I start mirroring a port, at which time, if I happen to be connected through one of the NICs I have dedicated to mirroring, I lose my remote desktop. I am aware that I would have more control over the NICs using Linux. I want to explore Windows solutions before I go that route because reinstalling another OS would be inconvenient (but not impossible). I would likely use a version of Backtrack (3 or 4 not sure). I would also have to learn how to access the machine remotely but I've done it before so this would be a minor obstacle. Thank you for your assistance.

    Read the article

  • Connecting multiple access points

    - by mohsen farahanipoor
    I'm working on a big project. We want to create a wireless network throughout the building with 15 floors. My idea is that we should set up one unified wireless access point at least in each floor...in case of signal attenuate, we use Access point extender/repeater. I selected DWL-6600AP from among D-Link industrial access points. I want to implement a single wireless LAN throughout the building. Is it possible to combines multiple DWL-6600 access points to achieving just a single WLAN? Can a wireless switch controller do this task? Can these Access Points interfere with each other? What is the solution? I read D-Link website's learning materials, but I am still confused. My other question is around the connecting these APs to Wireless Switch Controller - Is it possible to use power line for connecting DWL-6600 to Wireless Switch Controller device? My main goal is that clients with portable devices such as laptops should be easily connected to the network to share & have communication without any more manual configuration as they are already connected to a single network.

    Read the article

  • Dual-monitor Windows XP, monitors are "identified wrong"

    - by Susan
    Trying to use a dual-monitor desktop system with Windows XP.... 1 graphics card... with digital/analog outputs. Picking: Desktop - Properties - Settings - Identify It shows "2" as my left monitor... and "1" as my right. How do I switch them around? Here's what I've tried so far: Switch the cables (I can't. I need the digital cable on the better monitor.) Switch the monitors (I can't. One has a few dead pixels.) Drag the 1+2 graphics around (That doesn't change the IDENTIFY numbers.) Pick "use as primary" or "extend" (That doesn't change the IDENTIFY numbers.) Anything else I can try? What exactly controls/switches the "IDENTIFY numbers" around? I know it can be done. For weeks I ran this exact set-up... with the CORRECT numbers appearing on the monitors.... then just recently... after a few reboots... they now appear "switched around".

    Read the article

  • Unable to connect to server after a certain amount of time

    - by Troy
    I am a business FIOS subscriber with 5 static IPs. I have the following network setup: Verizon provided ONT Dlink switch Dell server running Ubuntu 12.04 with iptables enabled and a static IP address. The makes/models of hardware are: FIOS ONT Alcatel-Lucent I-211M-H ONT D-Link D-Link Web Smart Switch DES-1228P Server Dell Optiplex 755 (Ubuntu 12.04 Server) I have iptables running on the server with http, https and ssh ports open. I can connect to a website on the server from an external computer, but after a certain amount of time (mins to hours), I can no longer connect. All I have to do to re-enable connectivity is connect to the server via SSH from a computer INSIDE the network. I don't have to actually login, I just have to establish a connection. I can then access the website externally again. I did some googling and it seems some of verizon's equipment had an ARP bug where the ARP entries would expire after a certain time period, but those issues all seem to be from back in 2009 - 2010. I know the switch has an 'auto learning Mac address' feature, but I'm not sure if that could be the problem or not. Does anyone have any ideas or advice on how I can troubleshoot this? Thanks!

    Read the article

  • What Device/System to use as a "router on a stick"

    - by Jeff Leyser
    I need to create several distinct VLANs, and provide a way for traffic to move between them. A "router on a stick" approach seems ideal: Internet | Router with Trunking Capability ("router on a stick") * * Trunk between router and switch * Switch with Trunking Capability | | | | | | | | | | | LAN 2 | LAN 4 | | 10.0.2.0/24 | 10.0.4.0/24 | | | | LAN 1 LAN 3 LAN 5 10.0.1.0/24 10.0.3.0/24 10.0.5.0/24 We have trunk-capable Layer-2 switches. The question is what to use as the router on a stick. My choices seem to be: 1) Use an existing Cisco 5505 ASA firewall. It appears the ASA can do the routing, but it's a 100Mbps device, and so seems sub-optimal at best 2) Buy a router. This seems overkill. 3) Buy a Layer-3 switch. Also seems overkill. 4) Use an existing Linux Box as a router 5) Use a new Linux box as a router' 6) Something I'm not thinking of I think either (4) or (5) is my best option, but I'm not sure how to choose between them. I expect the amount of traffic that has to cross the VLANs to be somewhat small, but bursty. How much load does routing add to a CentOS machine?

    Read the article

  • Internet setup for my office

    - by prakash
    We have two internet connections to our office and our current setup is like this.. The internet connections require pppoe log in so i take each cable and plug it into a wifi router and configure the router to log in to the pppoe and then plug in a cable from the router to a switch and distribute the internet throughout my office. The problem with this setup is it is really hard to monitor and im not able to monitor who is hogging internet usage and what he or she is actually using it for. apart from this we also have a nas setup which is routed through another switch . Could someone please throw a little light on how i can restructure this setup for easy monitoring and better transparency... ? each wan router is connected to a different switch and is distributed to users accordingly.. we have around 40 users in the office.. we want to setup a single linux box to which i want to connect the two wan connections and from there distribute it to all our users.... im looking for a solution where we do not have to invest more that buying a single pc and a couple of nics

    Read the article

  • Curious enigma of a network cable / connection / quality

    - by Foo Bar
    So, the situation is like this: I'm renting an apartment in a large house and I'm sharing internet with the landlord who lives downstairs. The internet is (in my best guess) optical 20/20Mbit. I don't know how it's all wired in his flat (haven't been there / seen it). Anyway, in my flat comes a cable which seems to be connected directly to the optic to ethernet router (and the password is the default one, so I have access, he he). There was a switch connected to that and to wires that go around the flat, and the wiring is terrible. It's even mixing phone and ethernet, and from what I see some cables are even interconnected!? Anyways, this cable that comes to my flat is very short. I can barely connect my computer on it, but if I do, I seem to get decent speed / performance. Not great, but decent. If, however, I connect switch to it (tried 2 different switches and a wifi switch) it's all blinking but I can't even connect to 192.168.1.1 (the router). DHCP fails, ping is losing 80-100% of replies. So I connected this cable directly to the other cable which goes to my work room, with a connector that has two female jacks and no electronics. Now when I connect my computer in my room, again, the performance is decent. When I connect WRT54GL (with tomato, DHCP disabled) to it and I plug a cable in this WRT and to my computer... the performance is gone. Download seems okay on Speedtest, but upload is .2Mbps and it's connecting forever. So what kind cable troll am I having here? Any ideas?

    Read the article

  • Diagnosing Random Network Lag

    - by uesp
    I'm having trouble diagnosing some random lag on a 6 server LAMP cluster serving a MediaWiki site. While we're serving some 100 pages/sec the servers themselves are running fine with less than 0.5 load, no locked processes, no paging, no errors being logged, etc.... Lag is present on all servers and is random: one minute its fine the next it's there. DNS lookups on the servers are randomly slow. For example time nslookup google.com varies randomly from a few milliseconds to several seconds and sometimes times out entirely. While we use IP addresses internally on the cluster this may be a symptom of the root issue. We are not running our own DNS server. The Apache server-status pages randomly lag or time out. Benchmarking using ab between servers shows a few loads sometimes take 3000 ms (almost exactly). Benchmarking server-status on the local server itself usually shows no issue (it showed a lag only once among a few hundred tests). The servers are sitting behind a switch and a firewall which I don't have any access to so I don't know their setup or status. While we are under heavier than normal load a 2 Mbps incoming and 20 Mbps outgoing traffic shouldn't be stressing the switch or firewall should it? My feeling is that it is the switch/firewall or something above them in the ISP like their DNS but can't confirm it. I need some other tests or methods of diagnosing this lag to try and narrow down the ultimate cause.

    Read the article

  • ubuntu suspend works, but then immediately starts

    - by Yoav Aner
    Having a strange problem after upgrading from Ubuntu 11.04 to 12.04. Previously I could suspend just fine, the computer will switch itself off. Pressing the ON button will switch it on and it will resume. After upgrading to 12.04 however, when I suspend it does (almost) the same, turns itself off, but about 2 seconds later, the computer turns itself on again, and it goes back to life from suspend. I haven't changed any of the hardware or BIOS and it was working before just fine. Also tried every possible switch of pm-suspend ; setting acpi_sleep=nonvs in /etc/default/grub and also this suggestion but nothing seems to make a difference... UPDATE: just tested suspend using the 12.04 liveCD and it was working perfectly fine... but when I boot normally it doesn't. ANOTHER UPDATE: After re-installing I noticed that I can suspend. However, after restoring my home folder - the strange suspend problem happens again. I then created a new user account. When I login to the other account I can suspend without a problem... So This seems specific to my account only. How/What can cause this in my own user settings?

    Read the article

  • Problem with connecting two different networks

    - by tanascius
    I have two networks: 192.168.13.0/24 (blue) and 192.168.15.0/24 (green). Computer A is connected to the 13-net, only. Computer B has two interfaces, one in each network. There is third computer that acts like a router and connects the 13-net to the 15-net (only in this direction). Now, I'd like to ping 192.168.15.100 from computer A to B. Unfortunately there is never a reply. But when I use a hub instead of a switch it works. In my opinion the ping packet travels through the switch to the router (which is the default route/gateway for A). The router sends the packet back to the switch to B. Probably B receives it on its 15-net interface but answers with it's 15th interface? Is this possible? The problem is, that B may have only a gateway 192.168.13.50 - but I am not really sure of it (B is a embedded system with limited configuration possibilities). Can anyone explain what happens here? Thank you!

    Read the article

  • Watchguard Firebox "split" fibre optic line into 2 interfaces

    - by fRAiLtY-
    We have a requirement on our Watchguard Firebox XTM505 to be able to split our incoming external interface, in this case a fibre optic dedicated leased line, 100/100. We use the line in our office of approx 30 machines however we also re-sell to an external company who utilise it to provide wireless internet solutions to the public. The current infrastructure is as follows: Data in (Leased Line) - Juniper SRX210 managed by ISP - 1 cable out into unmanaged Netgear switch - 1 cable into our firewall and office network, 1 cable to our external providers core router managed by them. We have been informed that having the unmanaged switch in the position it is poses a security risk and that a good option would be to get our Watchguard Firewall to perform the split, by separating our office onto a trusted interface, and by "passing through" the external line to their managed router. It is alleged that the Watchguard is capable of doing this and also rate limiting the interfaces, i.e. 20mbps for the trusted interface and 80mbps for the "pass-through", however Watchguard technical support don't seem to be able to understand what we're trying to achieve. Can anyone provide any advice on whether this is possible on a Watchguard device and how or perhaps if there's a better way of achieving this, perhaps with a managed switch instead of unmanaged? Cheers

    Read the article

  • PC doesn't POST with a certain model of PSU

    - by Core Xii
    I have this PC with an Asus P5N32-E SLI motherboard and an Intel Q6600 CPU. I got a new RX-5300 PSU, but it didn't work. The motherboard power LED is on fine When I switch power on, the PC powers up briefly (0.5-1 sec) then shuts down From there on out when I switch power on, it stays on, all fans and components seem to be receiving power, but the motherboard won't POST. No video output, no PC speaker beeps, nothing If I turn the hard switch on the PSU off and then back on again, go to step 2; The PC turns on and then off immediately again, and on subsequent power-ups it stays on but won't POST I disconnected every component but the motherboard, CPU and PSU. Still nothing. I tried three other models of PSU on this PC, both of higher (600) and lower (<300) wattage than the 530 on the RX-5300 and they all work fine. At this point I was convinced the PSU was faulty so I returned it. When the replacement arrived, it behaved exactly the same. So two different units of RX-5300 both with the same symptoms, neither working with this motherboard + CPU. Yet, three other models of PSU work perfectly fine. The PC store couldn't reproduce my problem with the returned PSU. I tried resetting the CMOS with the jumper. I tried with both the 4 and 4+4 (with and without the extra +4 connected) CPU connectors (curiously the RX-5300 comes equipped with both). Could it be a statistical probability that I get two units of the same model of PSU that are faulty in the exact same manner? Could the RX-5300 model itself be somehow incompatible with this motherboard? I was under the impression that PSUs were pretty much universal so long as you have the wattage. Could the motherboard be broken in some such a way as to work with certain PSUs but not others? What's going on here?

    Read the article

< Previous Page | 133 134 135 136 137 138 139 140 141 142 143 144  | Next Page >