Search Results

Search found 16800 results on 672 pages for 'alan long'.

Page 14/672 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • smartctl -t long isn't finishing

    - by xenoterracide
    I been running smartctl -t long on a drive for about 2 days now and it seems to be stalled at 10%. short and conveyance both passed. I have to send 1 of 2 drives purchased back I found badblocks with badblocks (none on this drive and I'ts made over a pass already). I'm just wondering if I should be concerned about this. smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: WDC WD10EARS-00Y5B1 Serial Number: WD-WMAV51582123 Firmware Version: 80.00A80 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon May 10 22:19:52 2010 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 241) Self-test routine in progress... 10% of test remaining. Total time to complete Offline data collection: (20100) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 231) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3031) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 2 3 Spin_Up_Time 0x0027 131 131 021 Pre-fail Always - 6408 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 12 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 148 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 10 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 7 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 174 194 Temperature_Celsius 0x0022 106 102 000 Old_age Always - 41 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed without error 00% 99 - # 2 Extended offline Interrupted (host reset) 10% 30 - # 3 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Hour-long shutdown duration "shutting down hyper-v virtual machine management service"

    - by icelava
    I have a Windows 2008 R2 server that is a Hyper-V host (Dell PowerEdge T300). Today for the first time I encountered an odd situation; i lost connection with one of the guest machines but logging on physically it seems the guest OS is still running but no longer contactable via the network. I tried to shut down the guest machine (Windows XP) but it would not shut down, getting stuck in a "Not responding" dialog box that cannot be dismissed. I used the Hyper-V management console to reset the machine and it could not get out of resetting state. I tried to save another Windows 2003 guest machine, and it would be progress with its Saving state (0%). The other running Windows 2003 guest was stuck in the logon dialog. My first suspicion is perhaps one of the Windows update patches this week (10 Nov 2011) may something to do with it, which was still pending a system restart. Well, since I could not do anything with Hyper-V i proceeded with the Windows Update restart, and now it is stuck half an hour at "Shutting down hyper-v virtual machine management service" Prior to restarting I did not observe any hard disk errors reported in the system event log; doubt it is a disk-related condition. Shall I force a hard reboot? UPDATE Ok so i left it hanging over an hour while attending to other matters, and thankfully the host cleanly restarted. I can operate the guest machines fine now. Phew. Hyper-V must have been crawling for some reason. The VMs have been observed to become slow in the past when the host has been up for a long duration (two weeks to a month), but never this slow. Would love to know what types of performance monitoring items i can observe to give a hint why this can happen. UPDATE 2012-02-13 In the months ever since, Hyper-V has stalled into this state another two times. It appears so randomly and without any error event logs to hint what is causing it enter this "drunkard" state. Just an Hyper-V management service timeout. Log Name: System Source: Service Control Manager Date: 13/2/2012 9:16:48 AM Event ID: 7043 Task Category: None Level: Error Keywords: Classic User: N/A Computer: elune Description: The Hyper-V Virtual Machine Management service did not shut down properly after receiving a preshutdown control. Event Xml: <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"> <System> <Provider Name="Service Control Manager" Guid="{555908d1-a6d7-4695-8e1e-26931d2012f4}" EventSourceName="Service Control Manager" /> <EventID Qualifiers="49152">7043</EventID> <Version>0</Version> <Level>2</Level> <Task>0</Task> <Opcode>0</Opcode> <Keywords>0x8080000000000000</Keywords> <TimeCreated SystemTime="2012-02-13T01:16:48.882901900Z" /> <EventRecordID>567844</EventRecordID> <Correlation /> <Execution ProcessID="764" ThreadID="8484" /> <Channel>System</Channel> <Computer>elune</Computer> <Security /> </System> <EventData> <Data Name="param1">Hyper-V Virtual Machine Management</Data> </EventData> </Event> The only means out of it is to restart the system.

    Read the article

  • ActionScript/Flex ArrayCollection of Number objects to Java Collection<Long> using BlazeDS

    - by Justin
    Hello, I am using Flex 3 and make a call through a RemoteObject to a Java 1.6 method and exposed with BlazeDS and Spring 2.5.5 Integration over a SecureAMFChannel. The ActionScript is as follows (this code is an example of the real thing which is on a separate dev network); import com.adobe.cairngorm.business.ServiceLocator; import mx.collections.ArrayCollection; import mx.rpc.remoting.RemoteObject; import mx.rpc.IResponder; public class MyClass implements IResponder { private var service:RemoteObject = ServiceLocator.getInstance().getRemoteOjbect("mySerivce"); public MyClass() { [ArrayElementType("Number")] private var myArray:ArrayCollection; var id1:Number = 1; var id2:Number = 2; var id3:Number = 3; myArray = new ArrayCollection([id1, id2, id3]); getData(myArray); } public function getData(myArrayParam:ArrayCollection):void { var token:AsyncToken = service.getData(myArrayParam); token.addResponder(this.responder); //Assume responder implementation method exists and works } } This will make a call, once created to the service Java class which is exposed through BlazeDS (assume the mechanics work because they do for all other calls not involving Collection parameters). My Java service class looks like this; public class MySerivce { public Collection<DataObjectPOJO> getData(Collection<Long> myArrayParam) { //The following line is never executed and throws an exception for (Long l : myArrayParam) { System.out.println(l); } } } The exception that is thrown is a ClassCastException saying that a java.lang.Integer cannot be cast to a java.lang.Long. I worked around this issue by looping through the collection using Object instead, checking to see if it is an Integer, cast it to one, then do a .longValue() on it then add it to a temp ArraList. Yuk. The big problem is my application is supposed to handle records in the billions from a DB and the id will overflow the 2.147 billion limit of an integer. I would love to have BlazeDS or the JavaAdapter in it, translate the ActionScript Number to a Long as specified in the method. I hate that even though I use the generic the underlying element type of the collection is an Integer. If this was straight Java, it wouldn't compile. Any ideas are appreciated. Solutions are even better! :)

    Read the article

  • How to cancel a long running WCF requests from silverlight 3

    - by Kim
    I have a silverlight 3 application that makes several long running requests to a WCF service. While these calls are in progress, any other later WCF calls are queued by silverlight 3 because it will only do two requests at the same time, thus making the application suck :( How can I cancel the long running blocking requests?

    Read the article

  • Simple "Long Polling" example code?

    - by dbr
    I can find lots of information on how Long Polling works (For example, this, and this), but no simple examples of how to implement this in code. All I can find is cometd, which relies on the Dojo JS framework, and a fairly complex server system.. Basically, how would I use Apache to serve the requests, and how would I write a simple script (say, in PHP) which would "long-poll" the server for new messages? The example doesn't have to be scaleable, secure or complete, it just needs to work!

    Read the article

  • Long Press in JavaScript?

    - by Randy Mayer
    Hi, Is it possible to implement "long press" in JavaScript (or jQuery)? How? HTML <a href="" title="">Long press</a> JavaScript $("a").mouseup(function(){ // Clear timeout return false; }).mousedown(function(){ // Set timeout return false; }); Thank you!

    Read the article

  • appassembler and long classpath

    - by Paul McKenzie
    I am using maven appassembler to create my assembly. My classpath is too long and I get "The input line is too long." The suggestion here is to use booter windows platform, but I'm constrained to use Java Service Wrapper. Any way I can use java6 wildcarded classpath and java service wrapper?

    Read the article

  • BitSet to and from integer/long

    - by ataylor
    If I have an integer that I'd like to perform bit manipulation on, how can I load it into a java.util.BitSet? How can I convert it back to an int or long? I'm not so concerned about the size of the BitSet -- it will always be 32 or 64 bits long. I'd just like to use the set(), clear(), nextSetBit(), and nextClearBit() methods rather than bitwise operators, but I can't find an easy way to initialize a bit set with a numeric type.

    Read the article

  • Winforms-how do I keep window fully painted/responsive during a long running synchronous request is

    - by Greg
    Hi, Background - For a winforms 3.5 c# application, I would like to keep the main window fully painted/responsive during a long running synchronous request. For example if the user moves the window. Question - Is there a way to achive this WITHOUT having to setup a separate thread or backgroundworker process? (e.g. like a way to call from within my long running transaction, "release a bit of CPU to mainform", at some points) thanks

    Read the article

  • How to hunt down a long running request in Rails

    - by Jake
    We have a customer complaining about a long running request. I found the request in the production.log but am not sure how to dig deeper into figuring out why it took so long. Is there any artifacts in the log that I should look for? Also the DB and View times don't add up to the total request time.

    Read the article

  • Validate a long type input

    - by Santiago
    I'm trying to validate that a user only enters a long value as input (long bigger than 0 actually). Compare and Range validator has DataTypeCheck for int values only. I was planning on using this class in a CustomValidator but then I would need to write both, client and server side validation code. Do you know of any other good way of doing this? Thanks!

    Read the article

  • Long Running Stored Proc - Report Progress Using BackgroundWorker & Timer

    - by daveywc
    While a long running stored proc (RMR_Seek) is executing (called via a Linq-To-SQL data context) I am trying to call another stored proc (RMR_GetLatestModelMessage) to check a table for the latest status message. The long running stored proc updates the table in question with status messages as it executes. I want to display the status message on a message panel to advise the user of the status of the execution of Proc_A. For various reasons it is not possible to determine how long RMR_Seek will take to execute so a progress bar with percentage increments is not feasible. I thought I'd found the way to do it by calling the long running stored proc from in a BackgroundWorker process DoWork event handler. This worked fine and allowed me to update my message panel with some dummy status messages that were NOT obtained via Proc_B while Proc_A was running. However now that I have tried to implement this fully by calling Proc_B to obtain the status messages I am running into problems that seem to be related to the mix of the backgroundworker and my System.Windows.Forms.Timer. An extract of the code I am using is below. I have tried many different ways around this but each one seems to present its own set of problems. The code below is problematic in the bw_DoWork event. The RMR_Seek stored proc gets called but does not execute properly - it also seems to be inconsistent as to whether _IsCompleted gets set to true. I'm sure there is a better way to achieve what I am trying to do. private bool _IsCompleted; private void RunRevenueSeek() { if (_SelectedModel == null) { MessageBox.Show("Please select a model from the list and try again.", "Model Generation", MessageBoxButtons.OK, MessageBoxIcon.Information); } else { var bw = new BackgroundWorker(); bw.DoWork += new DoWorkEventHandler(bw_DoWork); ProgressPanelControl.Visible = true; _IsCompleted = false; MessageTimer.Start(); // Has an interval of 3000 bw.RunWorkerAsync(); ProgressLabelControl.Text = "Refreshing Data"; this.Update(); ...more code goes here } } private void bw_DoWork(object sender, DoWorkEventArgs e) { using (var dc = new RevMdlrDataClassesDataContext()) { dc.CommandTimeout = 300; dc.RMR_Seek(_SelectedModel.ModelSet_ID); _IsCompleted = true; } } private void MessageTimer_Tick(object sender, EventArgs e) { string message = ""; if (_IsCompleted) { MessageTimer.Stop(); } else { using (var dc = new RevMdlrDataClassesDataContext()) { dc.CommandTimeout = 300; dc.RMR_GetLatestModelMessage(_SelectedModel.ModelSet_ID, ref message); ProgressLabelControl.Text = message; this.Update(); } } }

    Read the article

  • How long can a URL be?

    - by Spines
    How long can a URL be? I want to pass a lot of data through the query string. I think I remember that it depends on what different routers it passes through, but how long can the URL be and definitely not get truncated?

    Read the article

  • Get street address at lat/long pair

    - by Chris Wenham
    I've seen that it's possible to get the latitude and longitude (geocoding, like in Google Maps API) from a street address, but is it possible to do the reverse and get the street address when you know what the lat/long already is? The application would be an iPhone app (and why the app already knows lat/long), so anything from a web service to an iPhone API would work.

    Read the article

  • long vs. short branches in version control

    - by Vincenzo
    I wonder whether anyone knows some research done with the question "What is good/bad in long/short branches in version control?" I'm specifically interested in academic researches performed in this field. My questions are: What problems (or conflicts) long branches may produce and how to deal with them How to split a big task onto smaller branches/sub-tasks How to coordinate the changes in multiple short branches, related to the same code Thanks in advance for links and suggestions!

    Read the article

  • How long will an ASP.NET MVC application run

    - by Christoph
    I wonder how long will an ASP.NET (MVC) application run, when no new requests come in? Lets say I'm using an IOC Container ans have a Singleton Object serving to the clients. As far as I know it will serve different page requests. But how long will it live when no new request come in? Is there any timeout (maybe configured through IIS) that says when my app will shut down?

    Read the article

  • JPA and PostqreSQL: long string persistence

    - by emanemos
    Can anybody tell me how to persist long text using JPA (I use PostgreSQL)? Here's the way I defined a very long string in my class: @Lob private String body; However, this produces a field of type charactervarying(255) in the database. Furthermore, I've tried to use @Column annotation: @Column(columnDefinition="TEXT") private String body; But everything in vain. I would be gratefull for a helpfull comment on this problem.

    Read the article

  • Show context menu when link is long pressed in TextView

    - by Al
    I have a TextView with its MovementMethod set to LinkMovementMethod. Text added to the TextView is a combination of normal text and URLs. For URLs, I would like to offer a context menu when the URL is long pressed for doing things such as copying the address. I've had a look at the source for LinkMovementMethod but it doesn't seem to have any long pressed related code I could override. Any ideas on how to go around achieving this?

    Read the article

  • JSP functions - How to declare long as parameter in TLD

    - by Spines
    I'm getting an error WARNING: Method "pl" for function "pl" not found, I think its because I'm not declaring the parameters right. <function-signature>java.lang.String pl(java.lang.Long, java.lang.String)</function-signature> is what I have in the TLD. and public static String pl(long num, String str) is what I have in the .java file.

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >