Search Results

Search found 1328 results on 54 pages for 'mini dv'.

Page 14/54 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • Mac OS X: pushing all traffic through a VMWare VM

    - by bj99
    I want to set up an Astaro (Sophos) UTM in a Virtual Machine. The Setup should be at the end the following: Cable Modem (one IP adress) | [Ethernet] Sophos UTM (running as VM [VMWare Fusion 5] on the MacMini) | [WIFI] Airport Express v2 (for sharing Local Network to wireless and wired clients) 1)| [WIFI] 2)| [Ethernet over Thunderbolt Ethernet Adapter]* Clients MacMini (Local File Server) *To have the Mini also protected behind the UTM So the setup process for the UTM works fine, but then the problems start: I just have one external IP (from my cable modem provider)== So if I put the VM in briged mode my Internet connection drops, because the MacMini also has its IP adress. If I put the VM to NAT mode the Mini itself is not protected by the UTM So: is there a way to hide the en0 interface(Ethernet) and the en1 interface (Wifi) from the MacMini, so that they not even appear in System Preferences Network section but are available to the VM? That way the Mini must connect to the en2 interface (Thunderbolt adapter) to make any Internet/LAN connection and I just use the given single IP from the Cable Modem. Thaks for any suggestions... Sebastian

    Read the article

  • How to send Bluetooth audio to non-Bluetooth speakers?

    - by wonsungi
    In short, I am looking for a Bluetooth-3.5 mini stereo converter. What is this type of device called, and what are some of the best models (is there a difference in audio quality/lag)? I wish to connect some speakers (Altec Lansing inMotion IM7), which does not support Bluetooth, to my laptop (Lenovo X301) wirelessly. Currently, I can connect my laptop's headphone jack to the AUX jack on my speakers via a mini stereo cable. How do I replace this cable with some type of Bluetooth setup? I am not sure what this Bluetooth device is called. I thought I found something, but it actually does the opposite of what I need (3.5 mini stereo-Bluetooth). (My OS is Vista Enterprise, if that matters)

    Read the article

  • How's the latency with Mac VNC on Windows PC using a crossover cable?

    - by Vadoff
    I use a Windows 8 PC as my main system, and do some programming with Xcode which I use a virtual machine for. However, it doesn't run as smoothly as I would like, so I'm thinking about purchasing a Mac Mini. My question is if I connect my PC to the Mac Mini directly (via crossover cable, firewire, or usb), would I be able to control the Mac using VNC with almost no latency? If not, is there any other way I'd be able to use both my PC and the Mac Mini simultaneously (using the same peripherals)?

    Read the article

  • Mirror virtualized development environment

    - by David Casillas
    I work alone in some iOS projects in a local environment. I have been thinking in a way to be able to share my development environment between my Mac Mini and my MacBook. I mostly work at home in the Mini but sometimes I need to do a demo or work outside and I would like to have the development environment mirrored in both. I have think in using a virtual machine (via VirtualBox) with just my development tools instaled. Then I could synchronize that VM with some software between both computers so I will always have the exact environment no matter what computer I use. Is there any good reason not do do this way? I have not used Virtualization to much so I have no background on the subject. My basic setup will be: Mac Mini: i7 dual Core, 8Gb. OSX Mountain Lion Host OS: MacBook: 2.4 Core 2 Duo. 4Gb. OSX Lion Host OS. Virtual Box with Mountain Lion guest OS in both machines. XCode5, Simulator.

    Read the article

  • Oracle Virtualization at Oracle OpenWorld 2012

    - by Chris Kawalek
    Mini-Series Entry 1 of 3: Hands-On Virtualization This is the first entry of a 3 part mini-series aimed at highlighting server and desktop virtualization at this year’s Oracle OpenWorld.  Oracle OpenWorld 2012 is fast approaching! If you are as excited as we are about the fascinating new Oracle virtualization content featured at Oracle OpenWorld 2012, you won’t want to miss this blog mini-series. We will be highlighting sessions that cover advances and innovations in our products, our product strategy and roadmap, and hands on labs for step-by-step instructions from our field and product experts. In the blog mini-series you will learn about: The Oracle Virtualization general keynote session Hands-on labs  Key Oracle server and desktop virtualization sessions In this entry, we will cover the Oracle Virtualization keynote session and the hands-on labs you won't want to miss. General Session: Oracle Virtualization Strategy and Roadmap Session ID: GEN8725 Oracle offers the industry’s most complete and integrated virtualization portfolio enabling organizations to realize benefits beyond simple consolidation as they transform their data centers into flexible cloud-based infrastructures. Join Oracle executives and experts to learn about Oracle’s desktop-to-data-center virtualization solutions, such as the OS, with built-in management integration at all layers that can help you virtualize and manage the complete computing environment, from physical servers to virtual servers and applications. This “don’t-miss” session offers details of the latest product updates and strategy; product roadmaps; integration with enterprise applications; and real-world examples of how Oracle server, desktop, and storage virtualization is benefiting customers. Here are our top picks for Hands-On Labs for Oracle OpenWorld 2012: Oracle Virtual Desktop Infrastructure Performance and Tablet Mobility Session ID: HOL9907 This hands-on lab demonstrates the performance (using an industry-standard load tester) and roaming capabilities of Oracle Virtual Desktop Infrastructure with Oracle’s Sun Ray Clients, Apple iPad and other clients. Deploying an IaaS Environment with Oracle VM: Hands-On Lab  Session ID: HOL9558 This hands-on lab takes you through the planning and deployment of an infrastructure as a service (IaaS) environment with Oracle VM as the foundation. It covers a range of topics, from planning storage capacity, LUN creation, network bandwidth planning, and best practices to designing and streamlining the environment for ease of management. Learn from deeply experienced field engineers and product experts. Virtualize and Deploy Oracle Applications in Minutes with Oracle VM: Hands-On Lab Session ID: HOL9559 This hands-on lab is for application architects or system administrators who will need to deploy and manage Oracle Applications. You’ll learn how Oracle VM Templates can turn you into a power user who can virtualize and deploy complex Oracle Applications in minutes. Longtime field-experienced engineers and product experts will show you, step by step, how to download and import templates and deploy the applications. x86 Enterprise Cloud Infrastructure with Oracle VM 3.x and Sun ZFS Storage Appliance Session ID: HOL9870 The purpose of this hands-on lab is to demonstrate the functionality and usage of Oracle’s enterprise cloud infrastructure for x86 with Oracle VM 3.x. It covers:  Creation of VMs Migration of VMs  Quick and easy deployment of Oracle applications with Oracle VM Templates  Usage of the Storage Connect plug-in for the Sun ZFS Storage Appliance You can find these and other great sessions on the Oracle OpenWorld 2012 Content Catalogue. Start checking now to better plan and organize your week at the conference. Then you’ll be ready to sign up for all of your sessions in mid-July when the scheduling tool goes live. While the hands-on labs allow you to directly interact with Oracle virtualization products, the conference sessions allow you to hear from a wide variety of industry experts on how they're using they technology in real world deployments, solving specific challenges, and more. In tomorrow's entry, we'll start talking about the many conference sessions related to Oracle server and desktop virtualization you can attend during the show. See you then! - The Oracle Virtualization marketing team

    Read the article

  • Sorting GridView Formed With Data Set

    - by nani
    Following Code is for Sorting GridView Formed With DataSet Source: http://www.highoncoding.com/Articles/176_Sorting_GridView_Manually_.aspx But it is not displaying any output. There is no problem in sql connection. I am unable to trace the error, please help me. Thank You. public partial class _Default : System.Web.UI.Page { private const string ASCENDING = " ASC"; private const string DESCENDING = " DESC"; private DataSet GetData() { SqlConnection cnn = new SqlConnection("Server=localhost;Database=Northwind;Trusted_Connection=True;"); SqlDataAdapter da = new SqlDataAdapter("SELECT TOP 5 firstname,lastname,hiredate FROM EMPLOYEES", cnn); DataSet ds = new DataSet(); da.Fill(ds); return ds; } public SortDirection GridViewSortDirection { get { if (ViewState["sortDirection"] == null) ViewState["sortDirection"] = SortDirection.Ascending; return (SortDirection)ViewState["sortDirection"]; } set { ViewState["sortDirection"] = value; } } protected void GridView1_Sorting(object sender, GridViewSortEventArgs e) { string sortExpression = e.SortExpression; if (GridViewSortDirection == SortDirection.Ascending) { GridViewSortDirection = SortDirection.Descending; SortGridView(sortExpression, DESCENDING); } else { GridViewSortDirection = SortDirection.Ascending; SortGridView(sortExpression, ASCENDING); } } private void SortGridView(string sortExpression, string direction) { // You can cache the DataTable for improving performance DataTable dt = GetData().Tables[0]; DataView dv = new DataView(dt); dv.Sort = sortExpression + direction; GridView1.DataSource = dv; GridView1.DataBind(); } } aspx page asp:GridView ID="GridView1" runat="server" AllowSorting="True" OnSorting="GridView1_Sorting" /asp:GridView

    Read the article

  • How can I reuse .NET resources in multiple executables?

    - by Brandon
    I have an existing application that I'm supposed to take and create a "mini" version of. Both are localized apps and we would like to reuse the resources in the main application as is. So, here's the basic structure of my apps: MainApplication.csproj /Properties/Resources.resx /MainUserControl.xaml (uses strings in Properties/Resources.resx) /MainUserControl.xaml.cs MiniApplication.csproj link to MainApplication/Properties/Resources.resx link to MainApplication/MainUserControl.xaml link to MainApplication/MainUserControl.xaml.cs MiniApplication.xaml (tries to use MainUserControl from MainApplication link) So, in summary, I've added the needed resources and user control from the main application as links in the mini application. However, when I run the mini application, I get the following exception. I'm guessing it's having trouble with the different namespaces, but how do I fix? Could not find any resources appropriate for the specified culture or the neutral culture. Make sure \"MainApplication.Properties.Resources.resources\" was correctly embedded or linked into assembly \"MiniApplication\" at compile time, or that all the satellite assemblies required are loadable and fully signed. FYI, I know I could put the user control in a user control library but the problem is that the mini application needs to have a small footprint. So, we only want to include what we need.

    Read the article

  • how can I parse and group/do stats on user agent strings?

    - by user151841
    I have a database that has the various user-agent strings of visitors to our site. I'd like to do a 'survey' of them to see what browsers our users are using, so that I can know what features I can use in future development. Is there a tool to parse and run statistics on user-agent strings, or a bunch of strings like this? Ideally, I'd like to see a hierarchical grouping of the stats. For instance: Opera/9.80 (Windows Mobile; WCE; Opera Mobi/WMD-50301; U; en) Presto/2.4.13 Version/10.00 Opera/9.80 (J2ME/MIDP; Opera Mini/4.2.14912/1280; U; en) Presto/2.2.0 Opera/9.80 (J2ME/MIDP; Opera Mini/4.2.13918/812; U; en) Presto/2.2.0 Opera/9.64 (Macintosh; Intel Mac OS X; U; en) Presto/2.1.1 Opera/9.60 (J2ME/MIDP; Opera Mini/4.2.13918/786; U; en) Presto/2.2.0 Opera/9.60 (J2ME/MIDP; Opera Mini/4.0.10992/432; U; en) Presto/2.2.0 I'd like to see 6 entries for Opera, broken down into 3 for 9.80, 1 for 9.64 and 2 for 9.60, and so forth for all browsers. Other dimensions, such as OS, would cross the boundaries of the browser version hierarchy, but it might be nice to see also.

    Read the article

  • Internet Sharing on Mac Behind Proxy

    - by Ali Kazmi
    Hi, I have enabled the internet sharing via Airport on Mac mini successfully. I can connect to the Wifi network from my iPhone but can't browse the internet. The problem might be that the Mac mini uses a proxy to connect to the internet. Is there a way to make this work?

    Read the article

  • Script for run script on vbs

    - by user31568
    Hello everybody I have a script on vbscript Dim WSHShell, WinDir, Value, wshProcEnv, fso, Spath Set WSHShell = CreateObject("WScript.Shell") Dim objFSO, objFileCopy Dim strFilePath, strDestination Const OverwriteExisting = True Set objFSO = CreateObject("Scripting.FileSystemObject") Set windir = objFSO.getspecialfolder(0) objFSO.CopyFile "\dv.rt.ru\SYSVOL\DV.RT.RU\scripts\shutdown.vbs", windir&"\", OverwriteExisting strComputer = "." Set objWMIService = GetObject("winmgmts:" _ & "{impersonationLevel=impersonate}!\" _ & strComputer & "\root\cimv2") JobID = "1" Set colScheduledJobs = objWMIService.ExecQuery _ ("Select * from Win32_ScheduledJob") For Each objJob in colScheduledJobs objJob.Delete Next Set objNewJob = objWMIService.Get("Win32_ScheduledJob") errJobCreate = objNewJob.Create _ (windir & "\shutdown.vbs", "**093000.000000+660", _ True, 1 OR 2 OR 4 OR 8 OR 16 OR 32 OR 64, ,True, JobId) How make that shutdown.vbs not run once at 9:30 but run for 9:30 to 12:00

    Read the article

  • Script for run script on vbs

    - by user35729
    Hello everybody I have a script on vbscript Dim WSHShell, WinDir, Value, wshProcEnv, fso, Spath Set WSHShell = CreateObject("WScript.Shell") Dim objFSO, objFileCopy Dim strFilePath, strDestination Const OverwriteExisting = True Set objFSO = CreateObject("Scripting.FileSystemObject") Set windir = objFSO.getspecialfolder(0) objFSO.CopyFile "\dv.rt.ru\SYSVOL\DV.RT.RU\scripts\shutdown.vbs", windir&"\", OverwriteExisting strComputer = "." Set objWMIService = GetObject("winmgmts:" _ & "{impersonationLevel=impersonate}!\" _ & strComputer & "\root\cimv2") JobID = "1" Set colScheduledJobs = objWMIService.ExecQuery _ ("Select * from Win32_ScheduledJob") For Each objJob in colScheduledJobs objJob.Delete Next Set objNewJob = objWMIService.Get("Win32_ScheduledJob") errJobCreate = objNewJob.Create _ (windir & "\shutdown.vbs", "**093000.000000+660", _ True, 1 OR 2 OR 4 OR 8 OR 16 OR 32 OR 64, ,True, JobId) How make that shutdown.vbs not run once at 9:30 but run for 9:30 to 12:00

    Read the article

  • RAID1 rebuild fails due to disk errors

    - by overlord_tm
    Quick info: Dell R410 with 2x500GB drives in RAID1 on H700 Adapter Recently one of drives in RAID1 array on server failed, lets call it Drive 0. RAID controller marked it as fault and put it offline. I replaced faulty disk with new one (same series and manufacturer, just bigger) and configured new disk as hot spare. Rebuild from Drive1 started immediately and after 1.5 hour I got message that Drive 1 failed. Server was unresponsive (kernel panic) and required reboot. Given that half hour before this error rebuild was at about 40%, I estimated that new drive is not in sync yet and tried to reboot just with Drive 1. RAID controller complained a bit about missing RAID arrays, but it found foreign RAID array on Drive 1 and I imported it. Server booted and it runs (from degraded RAID). Here is SMART data for disks. Drive 0 (the one that failed first) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1 3 Spin_Up_Time POS--K 142 142 021 - 3866 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10432 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 112 106 000 - 31 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 198 000 - 3 And Drive 1 (the drive which was reported healthy from controller until rebuild was attempted) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 35 3 Spin_Up_Time POS--K 143 143 021 - 3841 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10455 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 114 105 000 - 29 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 3 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 In extended error logs from SMART I found: Drive 0 has only one error Error 1 [0] occurred at disk power-on lifetime: 10282 hours (428 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 18 00 00 00 6a 24 20 40 00 Error: IDNF at LBA = 0x006a2420 = 6956064 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 60 00 f8 00 00 00 6a 24 20 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 18 00 60 00 00 00 6a 24 00 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 80 00 58 00 00 00 6a 23 80 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 68 00 50 00 00 00 6a 23 18 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 10 00 10 00 00 00 6a 23 00 40 00 17d+20:25:18.104 WRITE FPDMA QUEUED But Drive 1 has 883 errors. I see only few last ones and all errors I can see look like this: Error 883 [18] occurred at disk power-on lifetime: 10454 hours (435 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 01 -- 51 00 80 00 00 39 97 19 c2 40 00 Error: AMNF at LBA = 0x399719c2 = 966203842 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:57.802 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:57.779 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:55.704 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:55.681 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:53.606 READ FPDMA QUEUED Given those errors, is there any way I can rebuild RAID back, or should I make backup, shutdown server, replace disks with new ones and restore it? What about if I dd faulty disk to new one from linux running on USB/CD? Also, if anyone have more experiences, what could be causes for those errors? Crappy controller or disks? Disks are about 1 year old, but it is pretty unbelievable to me that both would die within so short timespan.

    Read the article

  • Will HDCP cause problems with a MacBook Pro using a VGA projector?

    - by Andrew Grimm
    I'm planning on using a MacBook Pro with a projector that only has a VGA input (through the MBP's Mini DisplayPort and a Mini DisplayPort to VGA converter). Will this have problems with HDCP (High-bandwidth Digital Content Protection), either under Snow Leopard or Windows XP? I'll only be showing other people's photos, user-generated movies or PowerPoint slides. The MacBook Pro was purchased from Apple new in December 2009.

    Read the article

  • Networking switch setup

    - by Crash893
    I have two 48 port gigabit netgear switches with 2 SFP ports each (i also have two Mini-GBIC copper transceiver modules) Is it best to set the ports up by using the built in ports (ie plug port 1 of switchB into port 48 of switchA and port1 of switchA into the router) or is there an advantage to using the mini-gbic? (lets call the sfp ports 49 and 50) router - port 49 on switchA, port 50 switchA - port 49 SwitchB

    Read the article

  • Detecting a TPM chip?

    - by Danielb
    I have a HP Mini 311-1000CA netbook running Windows 7 Ultimate. I'd really like to encrypt the harddrive using BitLocker but I am unsure as to how to work out if the Mini has a TPM chip or not. Any ideas?

    Read the article

  • Script for run script

    - by user31568
    Hello everyone. There is script: Dim WSHShell, WinDir, Value, wshProcEnv, fso, Spath Set WSHShell = CreateObject("WScript.Shell") Dim objFSO, objFileCopy Dim strFilePath, strDestination Const OverwriteExisting = True Set objFSO = CreateObject("Scripting.FileSystemObject") Set windir = objFSO.getspecialfolder(0) objFSO.CopyFile "\dv.rt.ru\SYSVOL\DV.RT.RU\scripts\shutdown.vbs", windir&"\", OverwriteExisting strComputer = "." Set objWMIService = GetObject("winmgmts:" _ & "{impersonationLevel=impersonate}!\" _ & strComputer & "\root\cimv2") JobID = "1" Set colScheduledJobs = objWMIService.ExecQuery _ ("Select * from Win32_ScheduledJob") For Each objJob in colScheduledJobs objJob.Delete Next Set objNewJob = objWMIService.Get("Win32_ScheduledJob") errJobCreate = objNewJob.Create _ (windir & "\shutdown.vbs", "**093000.000000+660", _ True, 1 OR 2 OR 4 OR 8 OR 16 OR 32 OR 64, ,True, JobId) How make that shutdown.vbs run not at 9:00 once, but run for 9:00 to 12:00 Thanks

    Read the article

  • What happens to a Windows Dynamic Drive

    - by GruffTech
    In my windows (Windows 7) I have two primary logical volumns, One is on a SSD harddrive for my operating system and installed software, and my other is a Dynamic volume for my stored media. (I do alot of work with HD footage) I have all my media on the original DV tapes for backup purposes, just having them all available on my harddrive at all times is a major convience for me, well worth the few hundred dollar investment those 2TB drives were. Anyway, Long story short is my windows install has become problematic and I want to reformat windows. Does this, or will this effect my dynamic drive in any way? I've got almost 3 TB of video on there and i really dont want to re-import all my DV tapes.

    Read the article

  • Create and manage child name servers (glue records) within my domain?

    - by basilmir
    Preface I use a top level domain provider that only allows me to add "normal" third-party name servers (a list where i can add "ns1.hostingcompany.com" type entries... nothing else) AND "child name servers" which i can later attach to my parent account ( ns1.myowndomain.com and an ip address). They do not provide other means of linking up. I want to host my own server and dns, even with just one name server (at first). My setup: Airport Extreme - get's a static ip address from my ISP Mac Mini Server - sits behind the Airport and get's a 10.0.1.2 My problem is that i can't seem to configure DNS correctly. I added a "child nameserver" with my airport's external static ip address at the top level provider, so to my understanding i should have all DNS traffic redirected to my Airport. I've opened port 53 UDP to let the traffic in. Now, what i don't get is this. My Mini Server is sitting on a 10.0.1.2 address and i have setup dns correctly, with an A record to point and resolve my server AND a reverse lookup to that 10.0.1.2. So it's ok for "internal stuff". Here is the clicker... How, when a request comes from the exterior for a reverse lookup, does the server "know" ... well look i have everything in 10.0.1.2 but the guy outside needs something from my real address. I can't begin to describe the MX record bonanza... How do i set this "right"? Do i "need" my Mini Server to sit on the external address directly (i can see how this could be the preferred solution, being close to a "real" server i have in my mind). If not... do i need a PTR record on the 10.0.1.2 server but with the external address in there? My dream: I will extend this "setup" with multiple Mini's in different cities where i work. I want a distributed something (Xgrid comes to mind). PS. Be gentle, i've read 2 books and the subject, and bought both the Lynda Essentials and DNS and Networking to boot, still i'm far from being on top of things.

    Read the article

  • Is there a Linux distro specific for running as a host OS for Virtualization?

    - by harmh
    Hi, as I understand running VMware or other virtualizations requires a "host os". Normally this is one of your main os-es, that you really use. What I would like is a mini-linux and virtualization software pre-wrapped into a specialized bootalble, installable mini-os. So the linux would not have a webserver, nor X, just the minimum to run as a host OS and of course optimized for that, like some partitioning tools and such.

    Read the article

  • sql perfomance on new server

    - by Rapunzo
    My database is running on a pc (AMD Phenom x6, intel ssd disk, 8GB DDR3 RAM and windows 7 OS + sql server 2008 R2 sp3 ) and it started working hard, timeout problems and up to 30 seconds long queries after 200 mb of database And I also have an old server pc (IBM x-series 266: 72*3 15k rpm scsi discs with raid5, 4 gb ram and windows server 2003 + sql server 2008 R2 sp3 ) and same query start to give results in 100 seconds.. I tried query analyser tool for tuning my indexed. but not so much improvements. its a big dissapointment for me. because I thought even its an old server pc it should be more powerfull with 15k rpm discs with raid5. what should I do. do I need $10.000 new server to get a good performance for my sql server? cant I use that IBM server? Extra information: there is 50 sql users and its an ERP program. There is my query ALTER FUNCTION [dbo].[fnDispoTerbiye] ( ) RETURNS TABLE AS RETURN ( SELECT MD.dispoNo, SV.sevkNo, M1.musteriAdi AS musteri, SD.tipTurId, TT.tipTur, SD.tipNo, SD.desenNo, SD.varyantNo, SUM(T.topMetre) AS toplamSevkMetre, MD.dispoMetresi, DT.gelisMetresi, ISNULL(DT.fire, 0) AS fire, SV.sevkTarihi, DT.gelisTarihi, SP.mamulTermin, SD.miktar AS siparisMiktari, M.musteriAdi AS boyahane, MD.akisNotu AS islemler, --dbo.fnAkisIslemleri(MD.dispoNo) DT.partiNo, DT.iplikBoyaId, B.tanimAd AS BoyaTuru, MAX(HD.hamEn) AS hamEn, MAX(HD.hamGramaj) AS hamGramaj, TS.mamulEn, TS.mamulGramaj, DT.atkiCekmesi, DT.cozguCekmesi, DT.fiyat, DV.dovizCins, DT.dovizId, (SELECT CASE WHEN DT.dovizId = 2 THEN CAST(round(SUM(T .topMetre) * DT.fiyat * (SELECT TOP 1 satis FROM tblKur WHERE dovizId = 2 ORDER BY tarih DESC), 2) AS numeric(18, 2)) WHEN DT.dovizId = 3 THEN CAST(round(SUM(T .topMetre) * DT.fiyat * (SELECT TOP 1 satis FROM tblKur WHERE dovizId = 3 ORDER BY tarih DESC), 2) AS numeric(18, 2)) WHEN DT.dovizId = 1 THEN CAST(round(SUM(T .topMetre) * DT.fiyat * (SELECT TOP 1 satis FROM tblKur WHERE dovizId = 1 ORDER BY tarih DESC), 2) AS numeric(18, 2)) END AS Expr1) AS ToplamTLfiyat, DT.aciklama, MD.dispoNotu, SD.siparisId, SD.siparisDetayId, DT.sqlUserName, DT.kayitTarihi, O.orguAd, 'Çözgü=(' + (SELECT dbo.fnTipIplikler(SD.tipTurId, SD.tipNo, SD.desenNo, SD.varyantNo, 1) AS Expr1) + ')' + ' Atki=(' + (SELECT dbo.fnTipIplikler(SD.tipTurId, SD.tipNo, SD.desenNo, SD.varyantNo, 2) AS Expr1) + ')' AS iplikAciklama, DT.prosesOk, dbo.[fnYikamaTalimat](SP.siparisId) yikamaTalimati FROM tblDoviz AS DV WITH(NOLOCK) INNER JOIN tblDispoTerbiye AS DT WITH(NOLOCK) INNER JOIN tblTanimlar AS B WITH(NOLOCK) ON DT.iplikBoyaId = B.tanimId AND B.tanimTurId = 2 ON DV.id = DT.dovizId RIGHT OUTER JOIN tblMusteri AS M1 WITH(NOLOCK) INNER JOIN tblSiparisDetay AS SD WITH(NOLOCK) INNER JOIN tblDispo AS MD WITH(NOLOCK) ON SD.siparisDetayId = MD.siparisDetayId INNER JOIN tblTipTur AS TT WITH(NOLOCK) ON SD.tipTurId = TT.tipTurId INNER JOIN tblSiparis AS SP WITH(NOLOCK) ON SD.siparisId = SP.siparisId ON M1.musteriNo = SP.musteriNo INNER JOIN tblTip AS TP WITH(NOLOCK) ON SD.tipTurId = TP.tipTurId AND SD.tipNo = TP.tipNo AND SD.desenNo = TP.desen AND SD.varyantNo = TP.varyant INNER JOIN tblOrgu AS O WITH(NOLOCK) ON TP.orguId = O.orguId INNER JOIN tblMusteri AS M WITH(NOLOCK) INNER JOIN tblSevkiyat AS SV WITH(NOLOCK) ON M.musteriNo = SV.musteriNo INNER JOIN tblSevkDetay AS SVD WITH(NOLOCK) ON SV.sevkNo = SVD.sevkNo ON MD.mamulDispoHamSevkno = SV.sevkNo LEFT OUTER JOIN tblTop AS T WITH(NOLOCK) INNER JOIN tblDispo AS HD WITH(NOLOCK) ON T.dispoNo = HD.dispoNo AND T.dispoTuruId = HD.dispoTuruId ON SVD.dispoTuruId = T.dispoTuruId AND SVD.dispoNo = T.dispoNo AND SVD.topNo = T.topNo AND MD.siparisDetayId = HD.siparisDetayId ON DT.dispoTuruId = MD.dispoTuruId AND DT.dispoNo = MD.dispoNo LEFT OUTER JOIN tblDispoTerbiyeTest AS TS WITH(NOLOCK) ON DT.dispoTuruId = TS.dispoTuruId AND DT.dispoNo = TS.dispoNo --WHERE DT.gelisTarihi IS NULL -- OR DT.gelisTarihi > GETDATE()-30 GROUP BY MD.dispoNo, DT.partiNo, DT.iplikBoyaId, TS.mamulEn, TS.mamulGramaj, DT.gelisMetresi, DT.gelisTarihi, DT.atkiCekmesi, DT.cozguCekmesi, DT.fire, DT.fiyat, DT.aciklama, DT.sqlUserName, DT.kayitTarihi, SD.tipTurId, TT.tipTur, SD.tipNo, SD.desenNo, SD.varyantNo, SD.siparisId, SD.siparisDetayId, B.tanimAd, M.musteriAdi, M.musteriAdi, M1.musteriAdi, O.orguAd, TP.iplikAciklama, SD.miktar, MD.dispoNotu, SP.mamulTermin, DT.dovizId, DV.dovizCins, MD.dispoMetresi, MD.akisNotu, SV.sevkNo, SV.sevkTarihi, DT.prosesOk,SP.siparisId )

    Read the article

  • django blog - post- reply system display replies

    - by dana
    I have a mini blog app, and a reply system. I want to list all mini blog entries, and their replies, if there are any. i have in views.py def profile_view(request, id): u = UserProfile.objects.get(pk=id) paginator = New.objects.filter(created_by = request.user) replies = Reply.objects.filter(reply_to = paginator) return render_to_response('profile/publicProfile.html', { 'object_list': u, 'list':paginator, 'replies':replies }, context_instance=RequestContext(request)) and in the template: <h3>Recent Entries:</h3> {% for object in list %} <li>{{ object.post }} <br /> {% for object in replies %} {{ object.reply }} <br /> {% endfor %} mention : reply_to is a ForeignKey to New, and New is the name of the 'mini blog' table But it only shows all the replies for each blog entry, not the reply for every entry, if there is one thanks

    Read the article

  • How to stop/override a Jquery TimeOut function?

    - by Tom
    Hi, I have a small jquery snippet that displays notification message at the top of the screen in response to user actions on a page. The notification is often displayed after Ajax actions with dynamic content inside it. For example: $("#mini-txt").html("Thank you!"); $("#mini").fadeIn("fast"); setTimeout(function() {$("#mini").animate({height: "hide", opacity: "hide"}, "medium");}, 3000); The notification works well, except when a user does two or more actions in rapid succession, in which case the TimeOut function will confuse itself and the second message appears to come inside the previous 3000 milliseconds. Is there a way to "kill" the previous notification if a new action is performed. I've got no problem with the actions/selectors, just the TimeOut function.... either stopping it or overriding it somehow. Or perhaps there's a better alternative for getting the message to linger on the screen for a few seconds before disappearing? Thank you.

    Read the article

  • Configure 27" 2560x1440 for a monitor with corrupt EDID

    - by Aras
    I am trying to get a monitor work with my Ubuntu laptop. The monitor is this cheap 27" Korean monitors which has a 2560x1440 resolution -- and nothing else. Here are some specifications of this monitor: 2560x1440 @60Hz Only one dual link DVI-D input -- no other input port (no HDMI or display port) no OSD no scalar reports corrupt EDID does 2560x1440 @60Hz, did I say that already? Anyways, the monitor works beautifully with my Ubuntu desktop which has an nVidia card with DVI output. However, I am having problem using this monitor with my laptop. After some searching around I found a few posts suggesting to use an active adaptor for mini display port, so I went and bought a mini display to dual link DVI-D adaptor.. When using this adaptor the monitor is recognized by nvidia-settings tool but with incorrect resolution information. As you can see the monitor is incorrectly recognized and there are no other resolution available to set. This post on ubuntu forums and this other post on overclock both suggest that the monitor is reporting corrupt EDID file. I have tried following their instructions, but so far I have not been able to display any image on the monitor from my laptop. The laptop I am using is an ASUS G75VW with a 1920x1080 screen. It has a VGA, an HDMI 1.4a, and a mini display port. The graphic card is an nvidia gforce gtx 660M with 2GB dedicated memory. I am running Ubuntu 12.10 on here which I upgrade from 12.04 a few weeks ago. As I said I have tried several suggestions, including specifying Modeline in xorg.conf and also linking to EDID files I found from those forum posts above. However, I am not sure if the EDID files I found are suitable for my monitor. I think the solution to my problem consist of obtaining the EDID file of my monitor and then fixing it and modifying xorg.conf to force nvidia driver to load the correct resolution. However, I am not sure what steps I need to take to do this. Here is the part of sudo xrandr --prop output that is related to this monitor: DP-1 connected 800x600+1920+0 (normal left inverted right x axis y axis) 0mm x 0mm SignalFormat: DisplayPort supported: DisplayPort ConnectorType: DisplayPort ConnectorNumber: 3 (0x00000003) _ConnectorLocation: 3 (0x00000003) 800x600 60.3*+ I was expecting to see the EDID file in this output as was mentioned in this post, but it is not there. After several hours of tweaking X configurations, I decided it was time to ask for help here. I would really appreciate if someone with experience regarding EDID and X configuration could give me a hand to solve this issue.

    Read the article

  • Do I need to match hardware on a Mac to my PC to get the same user experience?

    - by Darth
    I've been playing around with the thought of moving from a PC to a Mac. if you don't want to read this, skip to the "upgrade options" My current setup Most of my time I spent moving back and forth between Linux and Windows. During the last upgrade to Vista, I got myself pc with Core 2 Quad, 8GB of RAM and GeForce 9800GTX+. Currently I'm running dual boot between Ubuntu 10.04 and Windows Vista x64. Most of my work, around 80%, I can do on Ubuntu, which is mostly Ruby/Java programming. If that was all I needed, Ubuntu would be really great. However, I also do quite a lot of Photography and Design, which forces me to use Adobe software (not only Photoshop). I also work with Wacom Intuos4 tablet, which doesn't really have great support on Linux machines. I've tried virtualization both ways (Linux in Win and Win in Linux), but neither was anywhere near satisfying. These are those of many many reasons I want to move to OS X. Upgrade options This is how I see my upgrade options: Mac Mini - cheapest solution, but worst performance iMac - more expensive, better performing with second LCD for free Mac Pro - could match my current PC performance, currently outside of the price range When I compare the Mac hardware vs my current PC, it will be always worse, unless I decide to pump in a lot of money. The question that comes to my head, do I need to match my current PC hardware to get the same user experience with a Mac? If I look at it from the Vista point of view, 2GB RAM is as low as it gets, 4GB is usable ... and the 8GB runs very smoothly. PC HW != Mac HW? If I bought the Mac Mini for roughly the same price I paid for my PC (Core 2 Quad with 8GB RAM), I'd get Core 2 Duo with 4GB RAM. But I don't want to run Vista on it, so I can't compare the hardware directly. Say that I want to do the same things on the Mac Mini as I do on my PC, eg. open up 50 tabs in Google Chrome and start working with a large PSD in Photoshop (couple hundred MB), would running on Mac OS X compensate for the lower hardware performance? My point is, that if I'm about to upgrade, I wouldn't like to upgrade to hardware that runs a lot slower. Good analogy for this is Vista vs Ubuntu, where you can run Ubuntu smoothly on a low end laptop, but in Vista, you'd be happy to open a browser. Does the same principle apply to OS X?

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >