Search Results

Search found 62739 results on 2510 pages for 'windows 8 apps'.

Page 141/2510 | < Previous Page | 137 138 139 140 141 142 143 144 145 146 147 148  | Next Page >

  • Windows Physical Direct Memory Mapping

    - by chrisjleaf
    I'm a bit disappointed there is almost no discussion of this no matter where I look so I guess I'll have to ask. I'm writing a cross platform memory bench marking application which requires direct physical address mapping rather than virtual addressing. EDIT The solution would look something like the Linux/Unix system calls: int fd = open("/dev/mem", O_RDONLY); mmap(NULL, len, PROT_READ, MAP_SHARED, fd, PHYSICAL_ADDRESS_OFFSET); which will require the kernel to either give you a virtual page mapping to the desired physical address or return that it failed. This does require supervisor privileges but that is ok. I have seen a lot of information about shared memory and memory mapped files but all of these reside on disc and are thus not really useful when I'm trying to make a system dependent read. It is very similar to writing an IO driver although I do no need write permissions to the physical address. This site gives an example of how to do it on a driver level using the Windows Driver Kit: NT Insider: Sharing Memory between drivers and applications This solution would probably require Visual Studio which currently I do not have access to. (I have downloaded the WDK api but it complained about my use of GCC for Windows). I'm traditionally a Linux programmer so I'm hoping there might be something really simple I'm missing. Thanks in advance if you know something I don't!

    Read the article

  • windows 8 + Ubuntu dual boot

    - by Jack Yuan
    I installed Ubuntu 13.04 on Windows 8. Yes I can access both of them, but the process is kind of long. In BIOS, EFI is for Windows 8, legacy support is for Ubuntu. If I choose EFI first, the startup just go straight to Win8 without offering me a choice. If I choose legacy first, the starup will offer me a choice between win8 and ubuntu. But I can only choose Ubuntu. If i choose win8, there will be a mistake(file missing under configuration). That is to say, every time i wanna switch to another OS, I have to go into BIOS and change the priority settings. I heard something about secure boot might be the cause of this situation. But the thing is that there is not even an option called "secure boot" in my BIOS, which means i cannot disable it. All I want is that an option menu appears everytime i turn on my computer so i can easily choose what OS I want for today. Can anyone help me plz? Thank you very much!!

    Read the article

  • Dual Boot Windows 8 and Ubuntu

    - by Nick
    My laptop has two hard drives, one 320GB HDD and a 30GB SSD. I installed Windows 8 on the HDD and Ubuntu on the SSD. However, after I installed Ubuntu, Windows 8 did not appear on the boot list. I tried boot-repair, but this didn't help.Here is the output of my fdisk -l: Disk /dev/sda: 320.1 GB, 320072933376 bytes 255 heads, 63 sectors/track, 38913 cylinders, total 625142448 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x6cd9314a Device Boot Start End Blocks Id System /dev/sda1 * 2048 625139711 312568832 7 HPFS/NTFS/exFAT Disk /dev/sdb: 30.0 GB, 30016659456 bytes 255 heads, 63 sectors/track, 3649 cylinders, total 58626288 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x6cd93132 Device Boot Start End Blocks Id System /dev/sdb1 * 2048 207126 102539+ 83 Linux /dev/sdb2 208894 58626047 29208577 5 Extended /dev/sdb5 208896 4112383 1951744 82 Linux swap / Solaris /dev/sdb6 4114432 58626047 27255808 83 Linux Disk /dev/mmcblk0: 3965 MB, 3965190144 bytes 49 heads, 48 sectors/track, 3292 cylinders, total 7744512 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0009c694 Device Boot Start End Blocks Id System /dev/mmcblk0p1 * 8192 7744511 3868160 b W95 FAT32 I also tried sudo grub-update, but that also did nothing.

    Read the article

  • External USB attached drive works in Windows XP but not in Windows 7. How to fix?

    - by irrational John
    Earlier this week I purchased this "N52300 EZQuest Pro" external hard drive enclosure from here. I can connect the enclosure using USB 2.0 and access the files in both NTFS partitions on the MBR partitioned drive when I use either Windows XP (SP3) or Mac OS X 10.6. So it works as expected in XP & Snow Leopard. However, the enclosure does not work in Windows 7 (Home Premium) either 64-bit or 32-bit or in Ubuntu 10.04 (kernel 2.6.32-23-generic). I'm thinking this must be a Windows 7 driver problem because the enclosure works in XP & Snow Leopard. I do know that no special drivers are required to use this enclosure. It is supported using the USB mass storage drivers included with XP and OS X. It should also work fine using the mass storage support in Windows 7, no? FWIW, I have also tried using 32-bit Windows 7 on both my desktop, a Gigabyte GA-965P-DS3 with a Pentium Dual-Core E6500 @ 2.93GHz, and on my early 2008 MacBook. I see the same failure in both cases that I see with 64-bit Windows 7. So it doesn't appear to be specific to one hardware platform. I'm hoping someone out there can help me either get the enclosure to work in Windows 7 or convince me that the enclosure hardware is bad and should be RMAed. At the moment though an RMA seems pointless since this appears to be a (Windows 7) device driver problem. I have tried to track down any updates to the mass storage drivers included with Windows 7 but have so far come up empty. Heck, I can't even figure out how to place a bug report with Microsoft since apparently the grace period for Windows 7 email support is only a few months. I came across a link to some USB troubleshooting steps in another question. I haven't had a chance to look over the suggestions on that site or try them yet. Maybe tomorrow if I have time ... ;-) I'll finish up with some more details about the problem. When I connect the enclosure using USB to Windows 7 at first it appears everything worked. Windows detects the drive and installs a driver for it. Looking in Device Manager there is an entry under the Hard Drives section with the title, Hitachi HDT721010SLA360 USB Device. When you open Windows Disk Management the first time after the enclosure has been attached the drive appears as "Not initialize" and I'm prompted to initialize it. This is bogus. After all, the drive worked fine in XP so I know it has already been initialized, partitioned, and formatted. So of course I never try to initialize it "again". (It's a 1 GB drive and I don't want to lose the data on it). Except for this first time, the drive never shows up in Disk Management again unless I uninstall the Hitachi HDT721010SLA360 USB Device entry under Hard Drives, unplug, and then replug the enclosure. If I do that then the process in the previous paragraph repeats. In Ubuntu the enclosure never shows up at all at the file system level. Below are an excerpt from kern.log and an excerpt from the result of lsusb -v after attaching the enclosure. It appears that Ubuntu at first recongnizes the enclosure and is attempting to attach it, but encounters errors which prevent it from doing so. Unfortunately, I don't know whether any of this info is useful or not. excerpt from kern.log [ 2684.240015] usb 1-2: new high speed USB device using ehci_hcd and address 22 [ 2684.393618] usb 1-2: configuration #1 chosen from 1 choice [ 2684.395399] scsi17 : SCSI emulation for USB Mass Storage devices [ 2684.395570] usb-storage: device found at 22 [ 2684.395572] usb-storage: waiting for device to settle before scanning [ 2689.390412] usb-storage: device scan complete [ 2689.390894] scsi 17:0:0:0: Direct-Access Hitachi HDT721010SLA360 ST6O PQ: 0 ANSI: 4 [ 2689.392237] sd 17:0:0:0: Attached scsi generic sg7 type 0 [ 2689.395269] sd 17:0:0:0: [sde] 1953525168 512-byte logical blocks: (1.00 TB/931 GiB) [ 2689.395632] sd 17:0:0:0: [sde] Write Protect is off [ 2689.395636] sd 17:0:0:0: [sde] Mode Sense: 11 00 00 00 [ 2689.395639] sd 17:0:0:0: [sde] Assuming drive cache: write through [ 2689.412003] sd 17:0:0:0: [sde] Assuming drive cache: write through [ 2689.412009] sde: sde1 sde2 [ 2689.455759] sd 17:0:0:0: [sde] Assuming drive cache: write through [ 2689.455765] sd 17:0:0:0: [sde] Attached SCSI disk [ 2692.620017] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2707.740014] usb 1-2: device descriptor read/64, error -110 [ 2722.970103] usb 1-2: device descriptor read/64, error -110 [ 2723.200027] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2738.320019] usb 1-2: device descriptor read/64, error -110 [ 2753.550024] usb 1-2: device descriptor read/64, error -110 [ 2753.780020] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2758.810147] usb 1-2: device descriptor read/8, error -110 [ 2763.940142] usb 1-2: device descriptor read/8, error -110 [ 2764.170014] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2769.200141] usb 1-2: device descriptor read/8, error -110 [ 2774.330137] usb 1-2: device descriptor read/8, error -110 [ 2774.440069] usb 1-2: USB disconnect, address 22 [ 2774.440503] sd 17:0:0:0: Device offlined - not ready after error recovery [ 2774.590023] usb 1-2: new high speed USB device using ehci_hcd and address 23 [ 2789.710020] usb 1-2: device descriptor read/64, error -110 [ 2804.940020] usb 1-2: device descriptor read/64, error -110 [ 2805.170026] usb 1-2: new high speed USB device using ehci_hcd and address 24 [ 2820.290019] usb 1-2: device descriptor read/64, error -110 [ 2835.520027] usb 1-2: device descriptor read/64, error -110 [ 2835.750018] usb 1-2: new high speed USB device using ehci_hcd and address 25 [ 2840.780085] usb 1-2: device descriptor read/8, error -110 [ 2845.910079] usb 1-2: device descriptor read/8, error -110 [ 2846.140023] usb 1-2: new high speed USB device using ehci_hcd and address 26 [ 2851.170112] usb 1-2: device descriptor read/8, error -110 [ 2856.300077] usb 1-2: device descriptor read/8, error -110 [ 2856.410027] hub 1-0:1.0: unable to enumerate USB device on port 2 [ 2856.730033] usb 3-2: new full speed USB device using uhci_hcd and address 11 [ 2871.850017] usb 3-2: device descriptor read/64, error -110 [ 2887.080014] usb 3-2: device descriptor read/64, error -110 [ 2887.310011] usb 3-2: new full speed USB device using uhci_hcd and address 12 [ 2902.430021] usb 3-2: device descriptor read/64, error -110 [ 2917.660013] usb 3-2: device descriptor read/64, error -110 [ 2917.890016] usb 3-2: new full speed USB device using uhci_hcd and address 13 [ 2922.911623] usb 3-2: device descriptor read/8, error -110 [ 2928.051753] usb 3-2: device descriptor read/8, error -110 [ 2928.280013] usb 3-2: new full speed USB device using uhci_hcd and address 14 [ 2933.301876] usb 3-2: device descriptor read/8, error -110 [ 2938.431993] usb 3-2: device descriptor read/8, error -110 [ 2938.540073] hub 3-0:1.0: unable to enumerate USB device on port 2 excerpt from lsusb -v Bus 001 Device 017: ID 0dc4:0000 Macpower Peripherals, Ltd Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x0dc4 Macpower Peripherals, Ltd idProduct 0x0000 bcdDevice 0.01 iManufacturer 1 EZ QUEST iProduct 2 USB Mass Storage iSerial 3 220417 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 5 Config0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 4 Interface0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Update: Results using Firewire to connect. Today I recieved a 1394b 9 pin to 1394a 6 pin cable which allowed me to connect the "EZQuest Pro" via Firewire. Everything works. When I use Firewire I can connect whether I'm using Windows 7 or Ubuntu 10.04. I even tried booting my Gigabyte desktop as an OS X 10.6.3 Hackintosh and it worked there as well. (Though if I recall correctly, it also worked when using USB 2.0 and booting OS X on the desktop. Certainly it works with USB 2.0 and my MacBook.) I believe the firmware on the device is at the latest level available, v1.07. I base this on the excerpt below from the OS X System Profiler which shows Firmware Revision: 0x107. Bottom line: It's nice that the enclosure is actually usable when I connect with Firewire. But I am still searching for an answer as to why it does not work correctly when using USB 2.0 in Windows 7 (and Ubuntu ... but really Windows 7 is my biggest concern). OXFORD IDE Device 1: Manufacturer: EZ QUEST Model: 0x0 GUID: 0x1D202E0220417 Maximum Speed: Up to 800 Mb/sec Connection Speed: Up to 400 Mb/sec Sub-units: OXFORD IDE Device 1 Unit: Unit Software Version: 0x10483 Unit Spec ID: 0x609E Firmware Revision: 0x107 Product Revision Level: ST6O Sub-units: OXFORD IDE Device 1 SBP-LUN: Capacity: 1 TB (1,000,204,886,016 bytes) Removable Media: Yes BSD Name: disk3 Partition Map Type: MBR (Master Boot Record) S.M.A.R.T. status: Not Supported

    Read the article

  • How to improve Windows Server 2008 R2 to handle many connections?

    - by invisal
    It has been a few days so far that I am trying to figure how to solve this problem. First of all, I am running a website with an average daily page view of 350,000. Previously, all ads management (tracking click and impression that each ads has served) and content were served in a single server with the following spec: Server 1 OS: Windows 2008 R2 64-Bit CPU: Intel® Core™ i5 - 4 cores RAM: 8 GB Storage: 2 x 1 TB hard drives Bandwidth: 10 TB per month To improve our website speed, I decided to separate the ads management script to another dedicated server because we have more than 15 advertisers to 30 advertisers per each page. Server 2 OS: Windows 2008 R2 64-Bit CPU: Intel® Core™ i5 - 4 cores RAM: 4 GB Storage: 2 x 300 GB hard drives Bandwidth: 10 TB per month The Problem The problem is that Server 1 can handle both content and ads system. Now, that I take away the ads system and put it at Server 2. Server 2 can barely serve only ads system. Test First of all, I moved 75% of the ads to Server 2. And then, perform a ping to server: ping -t xxxxx. [I did the ping for 10 minutes and its following similar pattern as below] Reply from xxxxx bytes=32 time=290ms TTL=116 Reply from xxxxx bytes=32 time=289ms TTL=116 Reply from xxxxx bytes=32 time=320ms TTL=116 Reply from xxxxx bytes=32 time=286ms TTL=116 Reply from xxxxx bytes=32 time=286ms TTL=116 Reply from xxxxx bytes=32 time=348ms TTL=116 Reply from xxxxx bytes=32 time=284ms TTL=116 Then, I moved 100% of the ads to Server 2. Then, perform a ping to server again. [I did the ping for 10 minutes and its following similar pattern as below] Reply from xxxxx bytes=32 time=290ms TTL=116 Request timed out Reply from xxxxx bytes=32 time=320ms TTL=116 Reply from xxxxx bytes=32 time=286ms TTL=116 Request timed out Request timed out Reply from xxxxx bytes=32 time=284ms TTL=116 Attempts Increase MaxUserPort and TcpNumConnection Restart the server Increase IIS Max Instances and Instance MaxRequests Server Resource Only 10%-15% of the network connection is used Only 10%-15% of the CPU is used Only 25% of the memory is used

    Read the article

  • How do you monitor SSD wear in Windows when the drives are presented as 'generic' devices?

    - by MikeyB
    Under Linux, we can monitor SSD wear fairly easily with smartmontools whether the drive is presented as a normal block device or a generic device (which happens when the drive has been hardware RAIDed by certain controllers such as the one on the IBM HS22). How can we do the equivalent under Windows? Does anyone actually use smartmontools? Or are there other packages out there? The problem is that SCSI Generic devices just don't show up in Windows. If the drives aren't RAIDed we can see them fine. How I'd do it in Linux: sles11-live:~ # lsscsi -g [1:0:0:0] disk SMART USB-IBM 8989 /dev/sda /dev/sg0 [2:0:0:0] disk ATA MTFDDAK256MAR-1K MA44 - /dev/sg1 [2:0:1:0] disk ATA MTFDDAK256MAR-1K MA44 - /dev/sg2 [2:1:8:0] disk LSILOGIC Logical Volume 3000 /dev/sdb /dev/sg3 sles11-live:~ # smartctl -l ssd /dev/sg1 smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.32.49-0.3-default] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Device Statistics (GP Log 0x04) Page Offset Size Value Description 7 ===== = = == Solid State Device Statistics (rev 1) == 7 0x008 1 26~ Percentage Used Endurance Indicator |_ ~ normalized value sles11-live:~ # smartctl -l ssd /dev/sg2 smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.32.49-0.3-default] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Device Statistics (GP Log 0x04) Page Offset Size Value Description 7 ===== = = == Solid State Device Statistics (rev 1) == 7 0x008 1 3~ Percentage Used Endurance Indicator |_ ~ normalized value

    Read the article

  • Server Push / HTTP Streaming on Windows Mobile / Windows CE

    - by afriza
    Hi, I find that HTTP Streaming / Server Push is quite promising for my project. Does someone have any clue on how to implement this in Windows Mobile? .NET / Native / other implementations are welcomed. Preferably with permissive license. some links on HTTP Steaming / Server Push: - Push Technology - Streaming HTTP / Server Push - Cross-browser implementation of “HTTP Streaming” (push) AJAX pattern - XEP-0124: Bidirectional-streams Over Synchronous HTTP (BOSH) I was thinking of using some Qt XMPP library (QXmpp) to do the job, but I'm not sure if it's up for the task and I also want to hear some opinions on this.

    Read the article

  • Installing Windows Management Framework 3.0 basically destroyed WMI, how can I fix it without reinstalling the O.S.?

    - by Massimo
    Related, of course, to this question. Before discovering it was somewhat... dangerous, I installed Windows Management Framework 3.0 on a number of Windows Server 2008 R2 SP1 servers, and WMI got completely trashed on all of them. This is what the WMI namespace looks like on a normal server (this is from Server Manager - Configuration - WMI Control): This is what it looks like after installing WMF 3.0: Yeah. Everything except WMF 3.0's new features is gone. Needless to say, nothing seems to work anymore on those servers. And no, this is not due to some strange installation error, this happened on three servers which were perfectly working before installing WMF 3.0, and on all of them the installation completed succesfully. Admittedly, one of them had a somewhat complex setup (various System Center products and SQL Server instances)... but two of them are just plain standard domain controllers which do nothing else at all. How can I fix this mess without having to reinstall the O.S. on these servers? And why did it happen in the first place?

    Read the article

  • How is route automatic metric calculated on Windows 7?

    - by e-t172
    KB299540 explains how Windows XP automatically assign metrics to IP routes: The following table outlines the criteria that is used to assign metrics for routes that are bound to network interfaces of various speeds. Greater than 200 Mb: 10 Greater than 20 Mb, and less than or equal to 200 Mb: 20 Greater than 4 Mb, and less than or equal to 20 Mb: 30 Greater than 500 kilobits (Kb), and less than or equal to 4 Mb: 40 Less than or equal to 500 Kb: 50 However, they seem to have changed their algorithm in Windows 7, as my routing table looks like this: IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 192.168.0.1 192.168.0.3 10 0.0.0.0 0.0.0.0 10.202.254.254 10.202.1.2 286 10.202.0.0 255.255.0.0 On-link 10.202.1.2 286 10.202.1.2 255.255.255.255 On-link 10.202.1.2 286 10.202.255.255 255.255.255.255 On-link 10.202.1.2 286 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 192.168.0.0 255.255.255.0 On-link 192.168.0.3 266 192.168.0.3 255.255.255.255 On-link 192.168.0.3 266 192.168.0.255 255.255.255.255 On-link 192.168.0.3 266 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 192.168.0.3 266 224.0.0.0 240.0.0.0 On-link 10.202.1.2 286 255.255.255.255 255.255.255.255 On-link 10.202.1.2 40 =========================================================================== The only "correct" metric is the first one (Gigabit connection = 10). However, other routes using the Gigabit connection have metric = 266, my VPN has metric = 286, and loopback is 306 (?!). Any idea what's going on?

    Read the article

  • Give access to specific services on Windows 7 Professional machines?

    - by Chad Cook
    We have some machines running Windows 7 Professional at our office. The typical user needs to have access to stop and start a service for a local program they run. These machines have a local web server and database installed and we need to restrict access to certain folders and services related to the web server and database for these users. The setup I have tried so far is to add the typical user as a Power User. I have been able to successfully restrict them from accessing certain folders (as far as I can tell) but now they do not have access to the service needed for starting and stopping the local program. My thought was to give them access to the specific service but I have not had any luck yet. In searching the web for solutions the only results I have found relate to Windows Server 2000 and 2003 and involve creating security templates and databases through the Microsoft Management Console. I am hesitant to try an approach like this as these articles are typically older and I worry this method is outdated. Is there a better way to accomplish the end goal of giving the user permission to run the service and restrict their access to certain folders? If any clarification is needed on the setup or what we are trying to achieve, please let me know. Thanks in advance.

    Read the article

  • Looking for suggestions for hosting Windows 2000 Server in the cloud / VPS / etc?

    - by JohnyD
    I have a Windows 2000 Server, currently virtualized in Hyper-V, that I would like to get running off-site as a backup (cloud, VPS, etc). You can't virtualize in EC2 and I'm fairly certain there are no Server 2000 AMI's floating about (correct me if I'm wrong!). If anyone has a recommendation on how I can get a virtualized Windows 2000 Server running in a secure, remote environment I would be grateful. As far as locations go I'd be interested in both North America as well as Australia and Europe. In a nutshell, we're ploughing our way out of a legacy codebase and this server is the last that remains of the legacy apps. However, it is still very much used by our clients. Everything is backed up each night (data, images, etc) to tape which is then taken offsite. However, in the event of a fire I would love to have a backup legacy server to point DNS records to. So while I am rebuilding from the ashes our services would already be available. It would save a lot of time and make my managers all the more happy (and that's what it's all about, riighhtt? :D) Thank you all for your suggestions. Please let me know if I've left out any important information. Additional info: - the legacy codebase does not function properly in Server 2003

    Read the article

  • looking for information on porting Linux apps to windows

    - by claws
    Today I've encountered a very good book : UNIX to Linux® Porting: A Comprehensive Reference By Alfredo Mendoza, Chakarat Skawratananond, Artis Walker This reminded me of the thing I always wanted to know. "Porting Linux apps to Windows". I mean porting native Linux apps to native Windows with no platforms involved. If I can find any good book which explains this topic. I've lot of amazing linux command line tools in mind which needs a windows port. Please point me to relevant articles/tutorials/books. PS: please don't tell me to use linux emulation platforms like Cygwin.

    Read the article

  • Recent DDE / file open issue with Office 2007 affecting only a few machines, is a Windows Update to blame?

    - by kafka
    All our workstations run Windows 7 Professional 64 bit. It started with one, then another, then another couple of machines having a problem accessing Word files locally and on the network. This doesn't happen on my machine though. Affected users get the error message 'There was a problem sending the command to the program'. I've Googled for solutions, but none of the answers worked. They suggested deleting certain registry keys; unregistering and reregistering the program for DDE; resetting the way that the shell opens .docx programs etc. each to no avail. As it affects local and network shares I believe the problem lies with the clients, and not the server, and I'm starting to suspect that there could have been a recent Windows Update which has caused this. I've tried comparing the updates on my working machine with an affected machine, but I can't immediately see any major differences. Has anyone else recently encountered this problem? What are the best steps to take to further isolate what could be causing this?

    Read the article

  • Windows 7 Explorer: how to show total size of all files in current folder?

    - by matt wilkie
    In Windows XP Explorer one can turn on Status Bar which shows, among other things, the total size of all the files in the current folder, or if the cumulative size of the selected files. How do I get the same at-a-glance information in Windows 7? Selecting files doesn't count as it stops after 15 files, and it's rare that I'm concerned about total size with that few files (it's pretty easy to estimate in my head). thanks. UPDATE: Information derived from the context menu (select r-click properties) isn't "at a glance", and not as smooth as selecting files and clicking the details link at the bottom in any case. Thank you for fleshing out more of the available routes though. Yes Q19232 is similar to this one, though it is not a duplicate. That question is about looking for easy free-space on disk stats and this one is easy used-space by contents of this folder stats. The answer for both is the same though. You can't! Hopefully someone will figure how to get this lost feature back with a shell extension or something.

    Read the article

  • Looking for easiest, most simple solution to run a customised DNS Server for my local network on Windows 7.

    - by Jamie G
    I need to forward some websites, such as http://testing.server/ to an fixed IP address on my local network. I can do this easily on one computer using the hosts file. However, I need this to work for all machines on my network. I think the best way to do this will be to setup my own DNS Servers and add the custom DNS settings there. However, I'm looking for the simplest way possible to do this - I really don't want to spend hours setting up Unix Servers and running tricky terminal based scripts just to do this! My server is a standard Windows 7 machine. My dream would be a nice simple windows program with a GUI where I could input my ISP's DNS server and it would use those records, unless I had specifically set up my own DNS for a domain to use instead. If it had a web based admin system that was accessible from another computer on the network that would be even better. Does anyone know of anything that can do this? Many thanks indeed.

    Read the article

  • CaptureCameraDialog returns OK but does not save (Motorola ES400)

    - by Dominic
    Ok it seems like everyone in the world has issues with CaptureCameraDialog. In my case the result is OK, but when taking the photo there is a MessageBox that says "Error" that appears and disappears in the blink of an eye, then returns to my app (so I don't have time to actually read the error). It has not saved the file. It does not throw an error to my application. There is also another issue which is exactly the same as the issue talked about here (yet none of the fixes work for me). http://www.pcreview.co.uk/forums/thread-4025602.php Does anyone know how to get the "error message" that the dialogue box displays for an instant?

    Read the article

  • How can I disable flashing icons on Windows 7 taskbar?

    - by Jebego
    I set my Windows 7 taskbar to auto-hide. However, sometimes when a program changes or something new happens in a program, the taskbar will show its self, and its respective taskbar icon will begin flashing orange. Here's what I'm talking about: To make the taskbar hide again, I have click on the program before I can go back to what I was doing. Anyways, I personally find this very annoying, and would love to find a way to either: Prevent the taskbar from having such alerts. Prevent the taskbar from showing its self when it has such alerts. I've searched around quite a bit, and really only found answers to this for XP. I've also found another Stack Exchange Question looking for the same thing for Windows 7. However, none of the answers to the question were really what I'm looking for. I'm not looking to hide the taskbar, or control the number of flashes. However, this answer seems to be what I'm looking for, so I downloaded and tried out the program. It works perfectly, other than the fact that the start menu icon is always shown, regardless of the taskbar being set to auto-hide. So, any ideas on how to fix this problem?

    Read the article

  • Windows/C++: detect when focus has changed between windows (globally)

    - by twig
    I'm trying to find a way to detect when focus is changed to another window (without having to poll every X ms). I've already figured out a way to detect when focus is switched between applications using WH_SHELL and HSHELL_ACTIVATESHELLWINDOW. The problem is I want to detect when focus is switched between dialog/windows within the same app. ie. In Notepad, I can determine when the app switches to Notepad, but I cannot detect when the "Open" or "Save" dialogs appear because the focus is still within the same application.

    Read the article

  • Windows 7 product key, which is the valid one - in registry or on a sticker?

    - by me how
    I am not too familiar with the software licensing and how this all works, but I have a question regarding Windows 7 and partially Office - generally Microsoft products. I have been asked to assist our IT guy who wants to collect all the product IDs for Windows 7 and Office. I haven't been given much details how to go about it and how to collect it. After a bit of research I have decided to use a freeware that pulls the software licenses out of the registry. I thought that was the easiest and would provide the most accurate product IDs. I've used Belrac Avisor to obtain all the informations. It turns out that about 25 machines use the same product key. I have asked if the company has bought a commercial license or something but there isn't anyone available at the moment who could answer my question. I have told the IT guy that there are 25 machines using the same product key and asked if that is alright. He told me to go around and write the product keys from the sticker(label) on each machine. I am just not quite sure if that's the right approach specially that the numbers do not match.... So, now I see that the numbers aren't matching and my question is in terms of software licensing which is the VALID and correct product key to provide if ever questioned about software license? Is it the number on the sticker or is it the number stored in the registry?

    Read the article

  • CreateProcessWithLogonW : unable to start process

    - by Vivek
    Hi I am completely new to programming. And please someone help me. I am trying to start a pocess from a service. I need to start the new process by prompting user to enter admin credentials. I was trying to use CreateProcessWithLogonW(). Am I using the right function. I tried to give input username, password, domain as localhost. I gave full pathe to the .exe file that i need to start. Here is the piece of code. CreateProcessWithLogonW(L"Administrator", L"localhost", L"password", 0, NULL, L"c:\myupdates\myapp.exe", NORMAL_PRIORITY_CLASS | CREATE_CONSOLE, NULL, NULL, &si, &pi); Si.cb = sizeof(si); Si.lpDesktop = L"winsta0\\default"; But the process never started. Can you guys tell me what I am doing wrong. And what do I need to do to promt user to enter credentials of administrator instead of hardcoding it.

    Read the article

  • GeoCoordinateWatcher doesnt fire the event at given intervals

    - by krrishna
    I have the below code which fires the GeoCoordinateWatcher PositionChanged event for every 0.5 meteres .It might be less.But thats my requirement. The issue is when i am walking with phone doesnt fire the event at every 0.5 meters instead it fires the event after 0.5 meters randomly.And sometimes when i move fast it fires few events one after another immediately. Can anybody help me with how to ensure it fires the positionchanged event for every 0.5 meters accurately . watcher = new GeoCoordinateWatcher(GeoPositionAccuracy.Default); if (watcher.Permission == GeoPositionPermission.Granted) { watcher.MovementThreshold = 0.5;//in meters } watcher.PositionChanged += new EventHandler<GeoPositionChangedEventArgs<GeoCoordinate>>(watcher_PositionChanged); // PositionChanged events occur whenever your position changes watcher.StatusChanged += new EventHandler<GeoPositionStatusChangedEventArgs>(watcher_OnStatusChanged); watcher.Start();

    Read the article

  • How to merge Windows registry hives directly without converting them to an intermediate text based file?

    - by Registrar
    Help! I'm going to get fired if I can't figure out how to do this by tomorrow. Microsoft Windows stores its registry databases (known as "registry hives" - there's actually a backstory to the origin of this name, but I digress) in a proprietary binary format. Answer this correctly or you lose your job: Let H-sub-A be the registry hive of Computer A, and let H-sub-B be the registry hive of Computer B. Create a registry hive H-sub-A-prime (in the native binary format) that contains all of the registry keys and values in both H-sub-A and H-sub-B. If there is overlap, let the value from H-sub-B overwrite the value in H-sub-A. Sure, you can import a text-based patch file (e.g., "FOO.REG") to modify the registry, but can you merge two registry hives in their native binary format? Answers that involve exporting the registry to a text file (e.g., "FOO.REG") will receive no credit. You may only use software included with Microsoft Windows (any version) and / or third-party tools that are free of charge.

    Read the article

  • Use IIS Application Initialization for keeping ASP.NET Apps alive

    - by Rick Strahl
    I've been working quite a bit with Windows Services in the recent months, and well, it turns out that Windows Services are quite a bear to debug, deploy, update and maintain. The process of getting services set up,  debugged and updated is a major chore that has to be extensively documented and or automated specifically. On most projects when a service is built, people end up scrambling for the right 'process' to use for administration. Web app deployment and maintenance on the other hand are common and well understood today, as we are constantly dealing with Web apps. There's plenty of infrastructure and tooling built into Web Tools like Visual Studio to facilitate the process. By comparison Windows Services or anything self-hosted for that matter seems convoluted.In fact, in a recent blog post I mentioned that on a recent project I'd been using self-hosting for SignalR inside of a Windows service, because the application is in fact a 'service' that also needs to send out lots of messages via SignalR. But the reality is that it could just as well be an IIS application with a service component that runs in the background. Either way you look at it, it's either a Windows Service with a built in Web Server, or an IIS application running a Service application, neither of which follows the standard Service or Web App template.Personally I much prefer Web applications. Running inside of IIS I get all the benefits of the IIS platform including service lifetime management (crash and restart), controlled shutdowns, the whole security infrastructure including easy certificate support, hot-swapping of code and the the ability to publish directly to IIS from within Visual Studio with ease.Because of these benefits we set out to move from the self hosted service into an ASP.NET Web app instead.The Missing Link for ASP.NET as a Service: Auto-LoadingI've had moments in the past where I wanted to run a 'service like' application in ASP.NET because when you think about it, it's so much easier to control a Web application remotely. Services are locked into start/stop operations, but if you host inside of a Web app you can write your own ticket and control it from anywhere. In fact nearly 10 years ago I built a background scheduling application that ran inside of ASP.NET and it worked great and it's still running doing its job today.The tricky part for running an app as a service inside of IIS then and now, is how to get IIS and ASP.NET launched so your 'service' stays alive even after an Application Pool reset. 7 years ago I faked it by using a web monitor (my own West Wind Web Monitor app) I was running anyway to monitor my various web sites for uptime, and having the monitor ping my 'service' every 20 seconds to effectively keep ASP.NET alive or fire it back up after a reload. I used a simple scheduler class that also includes some logic for 'self-reloading'. Hacky for sure, but it worked reliably.Luckily today it's much easier and more integrated to get IIS to launch ASP.NET as soon as an Application Pool is started by using the Application Initialization Module. The Application Initialization Module basically allows you to turn on Preloading on the Application Pool and the Site/IIS App, which essentially fires a request through the IIS pipeline as soon as the Application Pool has been launched. This means that effectively your ASP.NET app becomes active immediately, Application_Start is fired making sure your app stays up and running at all times. All the other features like Application Pool recycling and auto-shutdown after idle time still work, but IIS will then always immediately re-launch the application.Getting started with Application InitializationAs of IIS 8 Application Initialization is part of the IIS feature set. For IIS 7 and 7.5 there's a separate download available via Web Platform Installer. Using IIS 8 Application Initialization is an optional install component in Windows or the Windows Server Role Manager: This is an optional component so make sure you explicitly select it.IIS Configuration for Application InitializationInitialization needs to be applied on the Application Pool as well as the IIS Application level. As of IIS 8 these settings can be made through the IIS Administration console.Start with the Application Pool:Here you need to set both the Start Automatically which is always set, and the StartMode which should be set to AlwaysRunning. Both have to be set - the Start Automatically flag is set true by default and controls the starting of the application pool itself while Always Running flag is required in order to launch the application. Without the latter flag set the site settings have no effect.Now on the Site/Application level you can specify whether the site should pre load: Set the Preload Enabled flag to true.At this point ASP.NET apps should auto-load. This is all that's needed to pre-load the site if all you want is to get your site launched automatically.If you want a little more control over the load process you can add a few more settings to your web.config file that allow you to show a static page while the App is starting up. This can be useful if startup is really slow, so rather than displaying blank screen while the user is fiddling their thumbs you can display a static HTML page instead: <system.webServer> <applicationInitialization remapManagedRequestsTo="Startup.htm" skipManagedModules="true"> <add initializationPage="ping.ashx" /> </applicationInitialization> </system.webServer>This allows you to specify a page to execute in a dry run. IIS basically fakes request and pushes it directly into the IIS pipeline without hitting the network. You specify a page and IIS will fake a request to that page in this case ping.ashx which just returns a simple OK string - ie. a fast pipeline request. This request is run immediately after Application Pool restart, and while this request is running and your app is warming up, IIS can display an alternate static page - Startup.htm above. So instead of showing users an empty loading page when clicking a link on your site you can optionally show some sort of static status page that says, "we'll be right back".  I'm not sure if that's such a brilliant idea since this can be pretty disruptive in some cases. Personally I think I prefer letting people wait, but at least get the response they were supposed to get back rather than a random page. But it's there if you need it.Note that the web.config stuff is optional. If you don't provide it IIS hits the default site link (/) and even if there's no matching request at the end of that request it'll still fire the request through the IIS pipeline. Ideally though you want to make sure that an ASP.NET endpoint is hit either with your default page, or by specify the initializationPage to ensure ASP.NET actually gets hit since it's possible for IIS fire unmanaged requests only for static pages (depending how your pipeline is configured).What about AppDomain Restarts?In addition to full Worker Process recycles at the IIS level, ASP.NET also has to deal with AppDomain shutdowns which can occur for a variety of reasons:Files are updated in the BIN folderWeb Deploy to your siteweb.config is changedHard application crashThese operations don't cause the worker process to restart, but they do cause ASP.NET to unload the current AppDomain and start up a new one. Because the features above only apply to Application Pool restarts, AppDomain restarts could also cause your 'ASP.NET service' to stop processing in the background.In order to keep the app running on AppDomain recycles, you can resort to a simple ping in the Application_End event:protected void Application_End() { var client = new WebClient(); var url = App.AdminConfiguration.MonitorHostUrl + "ping.aspx"; client.DownloadString(url); Trace.WriteLine("Application Shut Down Ping: " + url); }which fires any ASP.NET url to the current site at the very end of the pipeline shutdown which in turn ensures that the site immediately starts back up.Manual Configuration in ApplicationHost.configThe above UI corresponds to the following ApplicationHost.config settings. If you're using IIS 7, there's no UI for these flags so you'll have to manually edit them.When you install the Application Initialization component into IIS it should auto-configure the module into ApplicationHost.config. Unfortunately for me, with Mr. Murphy in his best form for me, the module registration did not occur and I had to manually add it.<globalModules> <add name="ApplicationInitializationModule" image="%windir%\System32\inetsrv\warmup.dll" /> </globalModules>Most likely you won't need ever need to add this, but if things are not working it's worth to check if the module is actually registered.Next you need to configure the ApplicationPool and the Web site. The following are the two relevant entries in ApplicationHost.config.<system.applicationHost> <applicationPools> <add name="West Wind West Wind Web Connection" autoStart="true" startMode="AlwaysRunning" managedRuntimeVersion="v4.0" managedPipelineMode="Integrated"> <processModel identityType="LocalSystem" setProfileEnvironment="true" /> </add> </applicationPools> <sites> <site name="Default Web Site" id="1"> <application path="/MPress.Workflow.WebQueueMessageManager" applicationPool="West Wind West Wind Web Connection" preloadEnabled="true"> <virtualDirectory path="/" physicalPath="C:\Clients\…" /> </application> </site> </sites> </system.applicationHost>On the Application Pool make sure to set the autoStart and startMode flags to true and AlwaysRunning respectively. On the site make sure to set the preloadEnabled flag to true.And that's all you should need. You can still set the web.config settings described above as well.ASP.NET as a Service?In the particular application I'm working on currently, we have a queue manager that runs as standalone service that polls a database queue and picks out jobs and processes them on several threads. The service can spin up any number of threads and keep these threads alive in the background while IIS is running doing its own thing. These threads are newly created threads, so they sit completely outside of the IIS thread pool. In order for this service to work all it needs is a long running reference that keeps it alive for the life time of the application.In this particular app there are two components that run in the background on their own threads: A scheduler that runs various scheduled tasks and handles things like picking up emails to send out outside of IIS's scope and the QueueManager. Here's what this looks like in global.asax:public class Global : System.Web.HttpApplication { private static ApplicationScheduler scheduler; private static ServiceLauncher launcher; protected void Application_Start(object sender, EventArgs e) { // Pings the service and ensures it stays alive scheduler = new ApplicationScheduler() { CheckFrequency = 600000 }; scheduler.Start(); launcher = new ServiceLauncher(); launcher.Start(); // register so shutdown is controlled HostingEnvironment.RegisterObject(launcher); }}By keeping these objects around as static instances that are set only once on startup, they survive the lifetime of the application. The code in these classes is essentially unchanged from the Windows Service code except that I could remove the various overrides required for the Windows Service interface (OnStart,OnStop,OnResume etc.). Otherwise the behavior and operation is very similar.In this application ASP.NET serves two purposes: It acts as the host for SignalR and provides the administration interface which allows remote management of the 'service'. I can start and stop the service remotely by shutting down the ApplicationScheduler very easily. I can also very easily feed stats from the queue out directly via a couple of Web requests or (as we do now) through the SignalR service.Registering a Background Object with ASP.NETNotice also the use of the HostingEnvironment.RegisterObject(). This function registers an object with ASP.NET to let it know that it's a background task that should be notified if the AppDomain shuts down. RegisterObject() requires an interface with a Stop() method that's fired and allows your code to respond to a shutdown request. Here's what the IRegisteredObject::Stop() method looks like on the launcher:public void Stop(bool immediate = false) { LogManager.Current.LogInfo("QueueManager Controller Stopped."); Controller.StopProcessing(); Controller.Dispose(); Thread.Sleep(1500); // give background threads some time HostingEnvironment.UnregisterObject(this); }Implementing IRegisterObject should help with reliability on AppDomain shutdowns. Thanks to Justin Van Patten for pointing this out to me on Twitter.RegisterObject() is not required but I would highly recommend implementing it on whatever object controls your background processing to all clean shutdowns when the AppDomain shuts down.Testing it outI'm still in the testing phase with this particular service to see if there are any side effects. But so far it doesn't look like it. With about 50 lines of code I was able to replace the Windows service startup to Web start up - everything else just worked as is. An honorable mention goes to SignalR 2.0's oWin hosting, because with the new oWin based hosting no code changes at all were required, merely a couple of configuration file settings and an assembly directive needed, to point at the SignalR startup class. Sweet!It also seems like SignalR is noticeably faster running inside of IIS compared to self-host. Startup feels faster because of the preload.Starting and Stopping the 'Service'Because the application is running as a Web Server, it's easy to have a Web interface for starting and stopping the services running inside of the service. For our queue manager the SignalR service and front monitoring app has a play and stop button for toggling the queue.If you want more administrative control and have it work more like a Windows Service you can also stop the application pool explicitly from the command line which would be equivalent to stopping and restarting a service.To start and stop from the command line you can use the IIS appCmd tool. To stop:> %windir%\system32\inetsrv\appcmd stop apppool /apppool.name:"Weblog"and to start> %windir%\system32\inetsrv\appcmd start apppool /apppool.name:"Weblog"Note that when you explicitly force the AppPool to stop running either in the UI (on the ApplicationPools page use Start/Stop) or via command line tools, the application pool will not auto-restart immediately. You have to manually start it back up.What's not to like?There are certainly a lot of benefits to running a background service in IIS, but… ASP.NET applications do have more overhead in terms of memory footprint and startup time is a little slower, but generally for server applications this is not a big deal. If the application is stable the service should fire up and stay running indefinitely. A lot of times this kind of service interface can simply be attached to an existing Web application, or if scalability requires be offloaded to its own Web server.Easier to work withBut the ultimate benefit here is that it's much easier to work with a Web app as opposed to a service. While developing I can simply turn off the auto-launch features and launch the service on demand through IIS simply by hitting a page on the site. If I want to shut down an IISRESET -stop will shut down the service easily enough. I can then attach a debugger anywhere I want and this works like any other ASP.NET application. Yes you end up on a background thread for debugging but Visual Studio handles that just fine and if you stay on a single thread this is no different than debugging any other code.SummaryUsing ASP.NET to run background service operations is probably not a super common scenario, but it probably should be something that is considered carefully when building services. Many applications have service like features and with the auto-start functionality of the Application Initialization module, it's easy to build this functionality into ASP.NET. Especially when combined with the notification features of SignalR it becomes very, very easy to create rich services that can also communicate their status easily to the outside world.Whether it's existing applications that need some background processing for scheduling related tasks, or whether you just create a separate site altogether just to host your service it's easy to do and you can leverage the same tool chain you're already using for other Web projects. If you have lots of service projects it's worth considering… give it some thought…© Rick Strahl, West Wind Technologies, 2005-2013Posted in ASP.NET  SignalR  IIS   Tweet !function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0];if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src="//platform.twitter.com/widgets.js";fjs.parentNode.insertBefore(js,fjs);}}(document,"script","twitter-wjs"); (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • Windows Phone 7 review

    - by Jeff
    I finally got around to composing some thoughts on what I think about Windows Phone 7, and I posted those impressions on my personal blog. I'll save a few bytes and not repost it here.It should be obvious that my general impression is overwhelmingly positive. What I don't go into very deeply is how much I enjoy developing stuff for it. Baby Stopwatch was not even remotely hard to build, because it wasn't complex, but also because the platform itself is so easy to deal with. I've been messing around and building something a little more involved, and it too has been fun to work with. Sure, you have the quirks of Silverlight to work out, and then the phone-specific quirks after that, but it really is a lot of fun. If you haven't come up with a science project for the phone, I would encourage you to do so.Now if only I could find a gig here at Microsoft where people just build phone apps all day! (But not games... I know we already do that quite a bit.)

    Read the article

< Previous Page | 137 138 139 140 141 142 143 144 145 146 147 148  | Next Page >