Search Results

Search found 1808 results on 73 pages for 'hot spare'.

Page 15/73 | < Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >

  • What does this Express Edition look like, anyhow?

    - by TiborKaraszi
    Chances are that you rarely get to see the Express Edition of SQL Server if you mainly work with servers. This blog post is inspired from a forum discussion where some functionality is missing in SQL Server Management Studio (SSMS) and I suspected that the tools were installed as a Basic installation instead of Complete installation. So how do I check that? Difficult if I don’t have such an install to look at. I’m training this week and have a few spare machines to play with so I went ahead and installed...(read more)

    Read the article

  • New Best-in-Class Solutions in Supply Chain Planning - Part 1

    Hear Nadeem Syed, Oracle Group Vice President, Advanced Planning Products discusst Oracle's recently announced best-in-class Supply Chain Planning solutions: Advanced Planning Command Center, Demand Signal Repository, Spare Parts Planning and Manufacturing Operations Center. Gain an understanding of the capabilities of these ground-breaking planning solutions and what types of enterprises can benefit from them.

    Read the article

  • 5 Simple Steps to Improve Your Ranking

    If you just decided that you want search engine traffic and are not prepared to pay for sponsored links but have no clue where to start this is the first 5 steps. As long as you have a decently built website and 10 minutes to spare, this should be easy.

    Read the article

  • Does redirecting old site's URLs to new site's front page hurt a page's ranking?

    - by Kaivosukeltaja
    An old site that is being rewritten needs to have it's URLs redirected to the new site. There are a few hundred pages that may or may not have corresponding pages on the new site, probably with different slugs, and adding mappings manually will require more hours than we can spare. It was suggested that all old URLs be redirected to the new front page, but I remember reading somewhere that this confers a penalty in page rank because it's what link farmers do. Is this true or can we take the easy way out?

    Read the article

  • Poisoned Apple?

    <b>Linux User and Developer:</b> "The announcement of the iPad not only sent the internet into some kind of meltdown, it also became a talking point that found its way into the newspapers, everyday conversations and pretty much every media outlet with a spare minute in their schedules"

    Read the article

  • Do you work with Visual Studio?

    Red Gate is doing some research into Visual Studio add-ins for SQL development. If you can spare a moment to complete a short survey, or are interested in being part of the early access program (linked from the end of the survey), please click here. Get smart with SQL Backup ProPowerful centralised management, encryption and more.SQL Backup Pro was the smartest kid at school. Discover why.

    Read the article

  • Getting my stuff organised

    - by NeilHambly
    I start off by saying, "I'm not that organised" @ times and things just don't get done even If I want them too So having missed some of my own personal targets so far this year already, I thought I needed some better way to achieve on those targets and one of these is to be a "little" more organised with my spare time, so I have decided that I will "try out" the following to see if it helps For 3 weeks each month I will follow this routine (my evenings after...(read more)

    Read the article

  • How to test high load on a website? [closed]

    - by rFactor
    Possible Duplicate: How do you load test your application? Hi, I am nearing a point of finalizing a website and it will soon be released. We have bought some traffic and advertisement packages and the nature of the site makes it heavier than typical static-like websites. I am looking for hear good ways to test how well the site performs under heavy load. I already know ab. Got any other tips to spare?

    Read the article

  • Rebuilding a Mac Mini (early 2009)

    - by Kelly Jones
    This weekend I decided to rebuild the family’s Mac Mini.  It’s the early 2009 model and I hadn’t done it since we got it in March of 2009.  Even worse, I had done the import data step (or whatever Apple calls it) which brought over all of the data files and apps from our previous Mac.  AND that install goes back to before 2005, as far as I can remember.  SO, to say that “cruft” had built up in the operating system, is probably a bit of an understatement. The rebuild went pretty smoothly, especially since I had a couple of spare hard drives.  I hooked up a spare USB drive and formatted it for use with the Mac.  I then used Carbon Copy to clone the internal hard drive onto the USB drive.  (Carbon Copy is a great little app that I used several years ago and I was happy to see it was not only still around, but updated as well.) Once I had my backup, I shut down the Mac and replaced the internal hard drive.  I had purchased the hard drive last fall to use with my work laptop, but I got a new work laptop (with awesome dual SSDs) so I wasn’t using it anymore.  The replacement drive (Seagate Momentus 7200.4 ST9500420AS 500GB 7200 RPM 2.5" SATA 3.0Gb/s Internal Notebook Hard Drive) has more than double the original’s capacity and is also faster.  I’ll have to keep an eye on the temperature, since that 7200 drive will run hotter. Opening the Mac Mini is not for the easily intimidated!  That cool little case is quite the pain to open.  Luckily, OWC put a video together here.  After replacing the drive, I then installed a clean copy of OS 10.5 using the DVDs that came with the Mac.  After the OS, it was time to reinstall the apps.  I downloaded some of the freeware, just to make sure I had the latest versions.  For the rest, I just copied from the backup cloned drive to the new drive.  (I love the way most Mac apps are written – with almost everything contained within a “package” that I can just copy from one drive to another.  MUCH better than the Windows way of using shared DLLs and the registry to store critical pieces that the app needs in order to run!) The whole process took longer than I would have preferred, but it was long overdue.  It definitely “feels” faster, especially boot time and application launches.

    Read the article

  • SQL SERVER Attach mdf file without ldf fileinDatabase

    Background Story: One of my friends recently called up and asked me if I had spare time to look at his database and give him a performance tuning advice. Because I had some free time to help him out, I said yes. I asked him to send me the details of his database structure and [...]...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Would there be any negative side-effects of sharing /var/cache/apt/ between two systems?

    - by ændrük
    In the interest of conserving bandwidth, I'm considering mounting a VirtualBox host's /var/cache/apt as /var/cache/apt in the guest. Both host and guest are Ubuntu 10.10 32-bit. Would there be any negative consequences to doing this? I'm aware of the more robust solutions like apt-proxy, but I'd prefer this simpler solution if it's possible in order to spare the host the overhead of running extra services.

    Read the article

  • 5 years of university education vs. 5 years of work experience - Which would you pick if hiring? [closed]

    - by gablin
    Say you need to hire a programmer. You have two candidates at your table: one has studied 5 years at uni (and holds a Master's degree, of course), but has no work experience; and the other holds no university degree but has worked for 5 years. Also assume that they both know the same programming languages, have about the same personality and spend equal amount of time programming on their spare time. If you only had this information to go on, which would you pick?

    Read the article

  • Mouse Clicks, Reactive Extensions and StreamInsight Mashup

    I had an hour spare this afternoon so I wanted to have another play with Reactive Extensions in .Net and StreamInsight. I also didn’t want to simply use a console window as a way of gathering events so I decided to use a windows form instead. The task I set myself was this. Whenever I click on my form I want to subscribe to the event and output its location to the console window and also the timestamp of the event.

    Read the article

  • Help us improve SQL Source Control

    We've been working really hard on SQL Source Control, and need your input. We're currently working on suggestions from our user forum and on an updated migrations feature that supports all source control systems and works across branches. We'd love it if you could spare 10 minutes to complete this survey. If you complete the survey by Friday June 14, you could win a $100 Amazon voucher. There are two up for grabs!

    Read the article

  • What's New in Oracle Supply Chain Management: Key highlights of R12.1 and new solutions (PART 2 of 2

    The latest EBS 12.1 release provides significant new capabilities in supply chain management that companies can deploy immediately to drive rapid ROI.  In addition, new solutions such as Advanced Planning Command Center, Spare Parts Planning, Demand Signal Repository and Manufacturing Operations Center enable companies to achieve operational excellence, while reducing costs and improving margins. This webcast will discuss the latest release, highlighting new capabilities and how companies can benefit from them.

    Read the article

  • What's New in Oracle Supply Chain Management: Key highlights of R12.1 and new solutions (PART 1 of 2

    The latest EBS 12.1 release provides significant new capabilities in supply chain management that companies can deploy immediately to drive rapid ROI.  In addition, new solutions such as Advanced Planning Command Center, Spare Parts Planning, Demand Signal Repository and Manufacturing Operations Center enable companies to achieve operational excellence, while reducing costs and improving margins. This webcast will discuss the latest release, highlighting new capabilities and how companies can benefit from them.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Dell 2950 Perc 6/i "physical disk" and "Enclosure(Backplane)" under Connector 1 in OMSA tree- Troubleshoot help

    - by user66357
    Just looking for someone who might know why this could occur... In OMSA, on my Dell 2950, there usually is only one "Physical Disks" child under "Enclosure (Backplane)" in the tree view. Currently, the tree looks like this: Dell PERC 6/i Integrated Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 removed) Physical Disks (1:33 Ready but unused) Normally it's like this: Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 good) From the front, 6 of 6 3.5" SAS drives are connected. The server is showing Slot 5 as bad and the disk as removed. It seems that the drive in Slot 5 is being sensed as external to the Enclosure. Any ideas why this would happen? Think I can get away with rebuilding the virtual disk by replacing 1:05 with 1:33? Thanks. UPDATE: The only options on the Physical Disk 1:33 were Assign as Global Hot Spare and Clear... After clearing, I assigned it as the Global Hot Spare. This allowed the rebuilding of the virtual disk. Hopefully it won't fail. I'm still unsure of the reason for this odd behavior. I'm checking the firmware next.

    Read the article

  • raid md device is not remove from memory, how to overcome this problem

    - by santhosha
    i create raid 10 , i removed two arrays form md11 one by one , after that i going to editing the contents those are mounted ( it will be not responding stage), after i try for remove arrays those are left it is shows device or resource busy ( is not removed from memory). i try to terminate process this is also not work, i absorve from 4 days resync will be 8.0% it can not modifying. cat /proc/mdstat Personalities : [raid1] [raid0] [raid6] [raid5] [raid4] [linear] [raid10] md11 : active raid10 sde1[3] sdj14 286743936 blocks 64K chunks 2 near-copies [4/1] [___U] [1:2:3:0] [=...................] resync = 8.0% (23210368/286743936) finish=289392.6min speed=15K/sec mdadm -D /dev/md11 /dev/md11: Version : 00.90.03 Creation Time : Sun Jan 16 16:20:01 2011 Raid Level : raid10 Array Size : 286743936 (273.46 GiB 293.63 GB) Device Size : 143371968 (136.73 GiB 146.81 GB) Raid Devices : 4 Total Devices : 2 Preferred Minor : 11 Persistence : Superblock is persistent Update Time : Sun Jan 16 16:56:07 2011 State : active, degraded, resyncing Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 Layout : near=2, far=1 Chunk Size : 64K Rebuild Status : 8% complete UUID : 5e124ea4:79a01181:dc4110d3:a48576ea Events : 0.23 Number Major Minor RaidDevice State 0 0 0 0 removed 1 0 0 1 removed 4 8 145 2 faulty spare rebuilding /dev/sdj1 3 8 65 3 active sync /dev/sde1 umount /dev/md11 umount: /dev/md11: not mounted mdadm -S /dev/md11 mdadm: fail to stop array /dev/md11: Device or resource busy lsof /dev/md11 COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME mount 2128 root 3r BLK 9,11 4058 /dev/md11 mount 5018 root 3r BLK 9,11 4058 /dev/md11 mdadm 27605 root 3r BLK 9,11 4058 /dev/md11 mount 30562 root 3r BLK 9,11 4058 /dev/md11 badblocks 30591 root 3r BLK 9,11 4058 /dev/md11 kill -9 2128 kill -9 5018 kill -9 27605 kill -9 30562 kill -3 30591 mdadm -S /dev/md11 mdadm: fail to stop array /dev/md11: Device or resource busy lsof /dev/md11 COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME mount 2128 root 3r BLK 9,11 4058 /dev/md11 mount 5018 root 3r BLK 9,11 4058 /dev/md11 mdadm 27605 root 3r BLK 9,11 4058 /dev/md11 mount 30562 root 3r BLK 9,11 4058 /dev/md11 badblocks 30591 root 3r BLK 9,11 4058 /dev/md11 cat /proc/mdstat Personalities : [raid1] [raid0] [raid6] [raid5] [raid4] [linear] [raid10] md11 : active raid10 sde1[3] sdj14 286743936 blocks 64K chunks 2 near-copies [4/1] [___U] [1:2:3:0] [=...................] resync = 8.0% (23210368/286743936) finish=289392.6min speed=15K/sec

    Read the article

  • Why does my dd backup of MacBook OS X fail to boot upon restore?

    - by James
    I created a backup of a MacBook hard drive (WD2500BEVS-88US) by hooking it up as a secondary drive on my linux system (Ubuntu 10.10). I used the following command: sudo dd if=/dev/sdc of=/home/backup.img bs=2M This appears to have completed with no errors. I noticed that the file is only 68 GB in size even though the drive is 250 GB in capacity. I restored the image to a spare drive (WD2500BEVS) with the following command: sudo dd if=/home/backup.img of=/dev/sdb bs=2M When I boot the spare drive in the Mac, it appears to start up for a few seconds and then shuts down. (It does not appear to load into the OS at all). When I open up the drive that won't boot in GParted, it looks like this: When looking at the information for the middle partition with the little red exclamation mark, it shows this: The original hard drive that boots ok shows up like this: Further info on both drives: sudo fdisk -l Disk /dev/sdb: 250.1 GB, 250059350016 bytes 255 heads, 63 sectors/track, 30401 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdb1 1 30402 244198580 ee GPT WARNING: GPT (GUID Partition Table) detected on '/dev/sdc'! The util fdisk doesn't support GPT. Use GNU Parted. Disk /dev/sdc: 250.1 GB, 250059350016 bytes 255 heads, 63 sectors/track, 30401 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdc1 1 30402 244198580 ee GPT So why is my backup or restore failing? Why is dd not creating a byte for byte duplicate?

    Read the article

  • Smart Array P400 battery failure

    - by RobIII
    The P400 Smart Array controller in my HP DL380G5 is indicating: Battery Status: Failed, Replace Battery 1 in the System Management Homepage. Also the IML indicates: POST Error: 1794-Drive Array - Array Accelerator Battery Charge Low I do have several replacement batteries (actually, several controllers including batteries) lying around at work but never had to actually replace one. I am wondering if the battery replacement (swap) could be done hot or if I need to take down my server to do the battery replacement. I have replaced other spare parts like fans and drives before and all those can be replaced hot. I just don't know about the battery of the P400 Smart Array controller. Any help would be appreciated. EDIT1 For those interested: straight from the horse's mouth: With thanks to Frands Hansen pointing it out here. EDIT2 In the end I did just power down, to be on the safe side and because the manual says so, and replace the battery. Couldn't be easier. Unplugged the old one of the end of the cable (not the end connected to the controller) and reconnected a spare one. The replaced battery is now in the server for about an hour and currently (still) recharging. I'm assuming all will end wel.

    Read the article

  • Running WordPress and Ghost on Apache with mod_proxy

    - by Jack Perry
    I currently have three WordPress sites hosted on Apache with virtual host files to direct the right domain to the right DocumentRoot. Ghost (node.js) just came out and I've wanted to tinker with it and just play around on one of my spare domains. I'm not really interested in moving over to nginx so I'm trying to get Ghost working on Apache via mod_proxy. I've managed to get Ghost working on my spare domain, but I think there's a problem with my virtual host files, as all of my other domains start pointing to Ghost as well. Here are two virtual host files, one for my main WordPress site that works fine, and the second for Ghost. Domains removed and replaced with DOMAIN and DOMAIN2. DOMAIN <VirtualHost *:80> ServerAdmin webmaster@localhost ServerName DOMAIN.com ServerAlias www.DOMAIN.com DocumentRoot /var/www/DOMAIN.com/public_html <Directory /> Options FollowSymLinks AllowOverride All </Directory> <Directory /var/www/DOMAIN.com/public_html> Options Indexes FollowSymLinks MultiViews AllowOverride All Order allow,deny allow from all </Directory> ScriptAlias /cgi-bin/ /usr/lib/cgi-bin/ <Directory "/usr/lib/cgi-bin"> AllowOverride None Options +ExecCGI -MultiViews +SymLinksIfOwnerMatch Order allow,deny Allow from all </Directory> ErrorLog ${APACHE_LOG_DIR}/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn CustomLog ${APACHE_LOG_DIR}/access.log combined Alias /doc/ "/usr/share/doc/" <Directory "/usr/share/doc/"> Options Indexes MultiViews FollowSymLinks AllowOverride None Order deny,allow Deny from all Allow from 127.0.0.0/255.0.0.0 ::1/128 </Directory> </VirtualHost> DOMAIN2 <VirtualHost IP:80> ServerAdmin EMAIL ServerName DOMAIN2.com ServerAlias www.DOMAIN2.com ProxyPreserveHost on ProxyPass / http://IP:2368/ </VirtualHost> I get the feeling I'm not working with virtual hosts or mod_proxy right, and Google-fu has let me down after many suggested attempts. Any ideas? Thanks!

    Read the article

  • Degraded RAID-5 array with lvm2 lost superblock and partition table

    - by Fred Phillips
    I have a RAID-5 array of 4x1TB hard disks with one lvm2 partition on Ubuntu Linux 10.04 LTS. One of the disks has failed. I have re-assembled the array without this failed disk but now mdadm --examine claims the array has no superblock and fdisk says it has no partition table. What can I do to recover the data? # mdadm -D /dev/md0 /dev/md0: Version : 1.2 Creation Time : Sat Mar 5 14:43:49 2011 Raid Level : raid5 Array Size : 2930276352 (2794.53 GiB 3000.60 GB) Used Dev Size : 976758784 (931.51 GiB 1000.20 GB) Raid Devices : 4 Total Devices : 4 Persistence : Superblock is persistent Update Time : Sat Mar 5 15:06:49 2011 State : clean, degraded Active Devices : 3 Working Devices : 3 Failed Devices : 1 Spare Devices : 0 Layout : left-symmetric Chunk Size : 512K Name : boba:1 (local to host boba) UUID : 52eb4bc9:c3d8aab5:e0699505:e0e1aa05 Events : 18 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 65 1 active sync /dev/sde1 2 8 49 2 active sync /dev/sdd1 3 0 0 3 removed 4 8 17 - faulty spare /dev/sdb1 # mdadm --examine /dev/md0 mdadm: No md superblock detected on /dev/md0. # fdisk -l /dev/md0 Disk /dev/md0: 3000.6 GB, 3000602984448 bytes 2 heads, 4 sectors/track, 732569088 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 524288 bytes / 1572864 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table # cat /proc/mdstat Personalities : [raid6] [raid5] [raid4] [linear] [multipath] [raid0] [raid1] [raid10] md0 : active raid5 sdb1[4](F) sda1[0] sdd1[2] sde1[1] 2930276352 blocks super 1.2 level 5, 512k chunk, algorithm 2 [4/3] [UUU_] unused devices: <none>

    Read the article

< Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >