Search Results

Search found 26093 results on 1044 pages for 'process monitor'.

Page 15/1044 | < Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >

  • Dual displays not working - NVidia - Ubuntu 12.04 - Second Monitor - Two Screens

    - by user75105
    Graphics Card: NVidia 460 GTX. Driver: NVIDIA accelerated graphics driver (version current) I have one DVI monitor, an old Dell LCD from 2005, and one VGA monitor, an Asus ML238H from 2010 whose HDMI port broke. The Asus is plugged into my graphics card's primary monitor slot and is the better monitor even though it is VGA but my computer defaults to the Dell. This happens when I boot as well; the loading screens, the motherboard brand image, etc. are all displayed on the Dell monitor until Windows loads. Then both monitors work. The same thing happened when I booted up Ubuntu 12.04 but I did not see the second monitor when the log-in screen popped up, nor did I when I logged in. I went to System Settings/Displays and my Asus monitor is not an option. I clicked Detect Displays and the Asus is not detected. I looked at the other questions regarding NVIDIA drivers and recalled my problems with Ubuntu a few years ago and decided to check the driver. I went to Additional Drivers to install the proprietary driver and it looks like it's installed and active but I'm still having this problem. There is another driver option, the post-release NVIDIA driver, but that does not fix the problem either. Also, under System Details/Graphics the graphics device is listed as Unknown, which might indicate that it is using an open source generic driver and not the proprietary NVidia driver. But under Additional Drivers it says that I am using the NVidia driver. Any help is appreciated.

    Read the article

  • parent process, and a child process..

    - by icelated
    I am trying to write a program that The parent process will take the arguments to main() and send the characters in them one at a time to the child process through a pipe (one call to write for each character). The child process will count the characters sent to it by the parent process and print out the number of characters it received from the parent. The child process should not use the arguments to main() in any way whatsoever. The child should return normally and not have the parent kill the child. Am i counting the arguments right? am i sending the arguments in one at a time, and am i reaping the child? #include <sys/wait.h> #include <stdio.h> #include <stdlib.h> #include <unistd.h> #include <string.h> #define size = 100; int main(int argc, char *argv[]) { int i, count =0; int c; int fdest[2]; // for pipe pid_t pid; //process IDs char buffer[BUFSIZ]; if (pipe(fdest) < 0) /* attempt to create pipe */ perror( "pipe" ); if ((pid = fork()) < 0) /* attempt to create child / parent process */ { perror( "fork" ); } /* parent process */ else if (pid > 0) { close(fdest[0]); for (i=1; i < argc; ++i) { for (c=0; c < strlen(argv[i]); ++c) { write(fdest[1], &argv[i][c], 1); } } close(fdest[1]); wait(NULL); exit(0); } else { /* child Process */ close(fdest[1]); while (read(fdest[0], &buffer, 1) > 0) { count++; } printf("\nchild: counted %d characters\n", count); } wait(NULL); exit(0); }

    Read the article

  • Laptop and 2 screens: use screens but not monitor display

    - by ClarkeyBoy
    Hi, I have 1 VGA socket on my laptop, and currently have that in use by a large screen. At some point in the future I would like to get another one of these screens and use both screens in dual screen mode but not use my laptop display (to be honest my laptop display is pretty rubbish as its like 2/3s the size of my screen - even if I had the choice to use all 3 I probably wouldn't want to). Is it possible to achieve this? If so, what do I need by way of hardware / software, and how much do you reckon it should cost me? Thanks in advance. Regards, Richard

    Read the article

  • Mac Mini monitor on the move – can I use VNC or a portable monitor?

    - by Jjunju
    I have been investigating the possibility of using my PC to control my soon to arrive Mac Mini when on the move. I can't afford and hope you don't give me answers suggesting buying a MacBook. My Mac Mini is the high end type. Now I have seen that the only viable option seems to be VNC. But how does this work if I am not on a network? Does VNC work with an ad-hoc network? Can a PC be connected to a Mac on such a network? Can this network be configured once at home and then be available on startup on the move? If I have an iPhone, can I use it as my wifi? But then, how would I start the Mac Mini to make the connection, since it wouldn't have a screen on the move? Finally, are there any small portable screens one can carry in a bag?

    Read the article

  • How does a so-called "LED monitor" work?

    - by sharptooth
    Every here and there I hear about new LED monitors. I imagined that they were really LED monitors - that their screens were formed of multiple tiny LEDs that lit up in a controlled manner to form an image. Yet turns out they are LED backlit LCD monitors. What's the difference between this and a trusty Belinea 10 17 51 I've been using for the five years already?

    Read the article

  • STOP: c000021a {Fatal System Error} The initial session process or system process terminated unexpectedly

    - by christof
    I'm encountering such an error after expanding disk space on a virtual machine using Hyper-V. STOP: c000021a {Fatal System Error} The initial session process or system process terminated unexpectedly with a status of (0x00000000) (0xc000012d 0x001003f0). The virtual server there is Windows Server 2008 R2 Enterprise Edition, which is also Domain Controller. I've tried to repair Windows but there is no restore point, and using the command line. I've tried the sfc /SCANNOW /OFFBOOTDIR /OFFWINDIR command, but I got the error Windows Resource Protection could not perform the requested operation.

    Read the article

  • monitor internet bandwidth

    - by enriquev
    Hello, I'm looking for a windows tool that can tell me who is using bandwith. As of now I've setup so that the switch where all pcs are connected, mirrors the router's traffic to my pc, meaning that from my NIC I am able to see all outgoing and incoming internet connections. This works, I have used NIMAS (http://www.vmware.com/appliances/directory/200) and I am able to see internet traffic. Now what I am looking for is something even more simple, where I can see what computers are using what banwidth, live.

    Read the article

  • Bandwidth monitor for apache websites

    - by bmaynard
    I am after a web application that will parse apache log files and record how much bandwidth the user has used. We have several virtual hosts that have custom log files and the I/O is recorded at the end of the logfile. However I can't find an application that will parse multiple log files and display a summary for each site. I believe awstats can do this but I want to be able to see all of my clients in one list. If there is something that integrates into cacti then that would be perfect.

    Read the article

  • Monitor turns off about 1 second after turning it on

    - by r0ca
    Hi all! I have a hardware issue with some of the LCD monitors we have in our office. My problems is not related to video cards or anything else with the computer itself. I have 2 Dell 17" LCD screens that goes off (blank) after 1 or 2 seconds. The light remains green so it's not idling or sleeping. Just this morning, I had to replace one that goes off on 2 workstations and also on my laptop. Nothing to do with it. I tried the VGA and DVI connection w/out luck. I strongly think that this is something with a capacitor or something inside the screen but I can't figure out what it is... Is anybody heard of that kind of issue before? Regards, David.

    Read the article

  • ATI Radeon Triple Monitor Setup

    - by Zak
    I have a Dell XPS 8300, and its got an ATI Radeon HD6450 installed. When running Ubuntu 12.04 the triple monitors work flawlessly. I can change the default, turn them on/off etc ... The problem is Windows 7. It is behaving much like in this thread. I know the card supports three, as it WORKS PERFECTLY in the linux portion of my dual boot. Windows can "see" all three, but will only allow two. Is this a WIndows 7 / ATI compatibility issue, or is Windows 7 just stupid (rhetorical)? Had I not had a dual boot Linux box, I might have read the above thread and thought "damn, it just won't work". But I use three monitors every day on this card, so I know it works.... Just not with Windows.

    Read the article

  • Add multi monitor option to remote desktop web access

    - by Eds
    I have a test environment for a remote desktop farm with a connection broker load balancing logins across remote desktop session host servers. All servers are built on Server 2012 R2. Using rd web access, we can access this farm from anywhere. When logging in via web access, you can choose the screen resolution or use full screen. If you have two monitors when selecting full screen, it will always use both your monitors. Does anyone know how to adjust the RDWeb page so that you can choose whether or not to use both your monitors? This option is in the GUI from RDP 6.1 onwards, so I would imagine there is a way to also add it the web access page.

    Read the article

  • COM+ automatic collection of a process dump file and process termination at high call time

    - by immi
    hI, I want to configure my machine for automatic collection of a process dump file and process termination as mentioned in http://support.microsoft.com/kb/910904. But after setting the registry settings according to the KB article, i am not getting the required behaviour. Only a warning is being logged when call time goes high (which is the default behaviour). i am running Windows Server 2003 with SP2. Is there any thing that i am missing? for example restart any COM+ runtime etc. Regards

    Read the article

  • Second monitor not detected

    - by Gabriel
    Hi I have two VGA monitors, my GPU is ATI PowerColor 6850 which has two DVI slots, I use adapters for both VGA monitors. If I connect any the two monitors in the first slot it will work right away (along the plugin confirmation sound). And if I connect any of both monitors to the second slot I won't get anything, nor a signal or confirmation sound. I also tried auto detecting via Catalyst Control Center and Windows Desktop Resolution. I have the latest drivers installed. EDIT: I found this on the Spec Description: Display Connectors DL-DVI-I/SL-DVI-D And in NewEgg: 2 x DVI (1 Single Link, 1 Dual Link) Could this have anything to do with my issue?

    Read the article

  • Program opens on disconnected and invisible monitor [closed]

    - by FiveO
    Possible Duplicate: Recover Windows Opening Off Screen? I'm working with a HP Elitebook 8460p with Windows 8 using always 2 Monitors connected. And some Programs I'm always opening on the second screen (which windows does automatically). But now the problem: When the screens aren't connected (when I'm at home), some programs still open on the second screen (which does not exist anymore) and it's just not possible to move them to the main (only!) screen! Does some one knows a solution for the problem - already bringing back the windows to the main screen would be enough. Thanks

    Read the article

  • Can no longer duplicate display to external monitor on Windows 7

    - by rbeier
    We have a large TV at work - I connect my laptop to it to share my screen during meetings. Until today, my laptop display has been duplicating to the TV automatically when I connect the TV cable to the laptop. The display resolution would decrease automatically to be compatible with the TV. Today, however, it's stopped working. When I connect the cable to the TV, the display extends rather than duplicating. Using the Win+P key combination (or Fn+F7 on my Lenovo laptop), I can choose to duplicate the display - but when I do this, it ends up only displaying on the laptop. I can get it to display on the TV by hitting Win+P and choosing "projector only", but then I can't see what I'm doing on the laptop screen. I have a Lenovo W520 laptop running Windows 7, connected to the TV using a DisplayPort-to-HDMI converter cable. The TV's native resolution is 1280x720; the laptop's native resolution is 1600x900. I've tried booting with the TV cable already connected; I've tried manually lowering the display resolution on the laptop to 1280x720 before duplicating the display. Neither works. Does anyone have any other suggestions?

    Read the article

  • Adobe Reader process fails when starting second instance

    - by Reddog
    In our C# WinForms application, we generate PDF files and launch Adobe Reader (or whatever the default system .pdf handler is) via the Process class. Since our PDF files can be large (approx 200K), we handle the Exited event to then clean up the temp file afterwards. The system works as required when a file is opened and then closed again. However, when a second file is opened (before closing Adobe Reader) the second process immediately exits (since Reader is now using it's MDI powers) and in our Exited handler our File.Delete call should fail because it's locked by the now joined Adobe process. However, in Reader we instead get: There was an error opening this document. This file cannot be found. The unusual thing is that if I put a debugger breakpoint before the file deletion and allow it to attempt (and fail) the deletion, then the system behaves as expected! I'm positive that the file exists and fairly positive that all handles/file streams to the file are closed before starting the process. We are launching with the following code: // Open the file for viewing/printing (if the default program supports it) var pdfProcess = new Process(); pdfProcess.StartInfo.FileName = tempFileName; if (pdfProcess.StartInfo.Verbs.Contains("open", StringComparer.InvariantCultureIgnoreCase)) { var verb = pdfProcess.StartInfo.Verbs.First(v => v.Equals("open", StringComparison.InvariantCultureIgnoreCase)); pdfProcess.StartInfo.Verb = verb; } pdfProcess.StartInfo.Arguments = "/N"; // Specifies a new window will be used! (But not definitely...) pdfProcess.SynchronizingObject = this; pdfProcess.EnableRaisingEvents = true; pdfProcess.Exited += new EventHandler(pdfProcess_Exited); _pdfProcessDictionary.Add(pdfProcess, tempFileName); pdfProcess.Start(); Note: We are using the _pdfProcessDictionary to store references to the Process objects so that they stay in scope so that Exited event can successfully be raised. Our cleanup/exited event is: void pdfProcess_Exited(object sender, EventArgs e) { Debug.Assert(!InvokeRequired); var p = sender as Process; try { if (_pdfProcessDictionary.ContainsKey(p)) { var tempFileName = _pdfProcessDictionary[p]; if (File.Exists(tempFileName)) // How else can I check if I can delete it!!?? { // NOTE: Will fail if the Adobe Reader application instance has been re-used! File.Delete(tempFileName); _pdfProcessDictionary.Remove(p); } CleanOtherFiles(); // This function will clean up files for any other previously exited processes in our dictionary } } catch (IOException ex) { // Just swallow it up, we will deal with trying to delete it at another point } } Possible solutions: Detect that the file is still open in another process Detect that the second process hasn't really been fully exited and that the file is opened in the first process instead

    Read the article

  • Start a thread in a different process in Java

    - by kolm
    Hi there, is it possible to start a new thread in a different process in Java? I mean, I'm running a specific process and main thread, issuing ProcessBuilder for creating a new process. Before start() method is invoked, one must provide the command to be run in another process. Is it possible to start a new thread in newly created process? Thank you in advance for the reply. Best regards.

    Read the article

  • change process windows style

    - by Suriyan Suresh
    I start IE as a process and then i would like to change the following properties of a process. remove title bar, toolbar of a process (if IE) set top,left location and size through c# prevent process from minimizing , i have used the following code but had no luck(find the handle of the process and then pass it to below function) public void SetFormOnDesktop(int hwnd) { int hwndf = hwnd; IntPtr hwndParent = FindWindow("ProgMan", null); SetParent(hwndf, hwndParent); }

    Read the article

  • How to get an instance of instance System.Diagnostics.Process by processID on a remote machine

    - by Tomas1
    Hi all, I want to run & control a process remotely, I found the best way is the WMI APIs, The WMI gives me information about the remote process but I need more control like waiting it and getting the standard output and errors, how can I do that, and can I get an instance of System.Diagnostics.Process class by instance ID remotely? note: I tried to get an instance of the Process by Process.GetProcessByPID and passign machineName parameter, but and Exception has thrown. Thanks in advance.

    Read the article

  • How to Use USER_DEFINED Activity in OWB Process Flow

    - by Jinggen He
    Process Flow is a very important component of Oracle Warehouse Builder. With Process Flow, we can create and control the ETL process by setting all kinds of activities in a well-constructed flow. In Oracle Warehouse Builder 11gR2, there are 28 kinds of activities, which fall into three categories: Control activities, OWB specific activities and Utility activities. For more information about Process Flow activities, please refer to OWB online doc. Most of those activities are pre-defined for some specific use. For example, the Mapping activity allows execution an OWB mapping in Process Flow and the FTP activity allows an interaction between the local host and a remote FTP server. Besides those activities for specific purposes, the User Defined activity enables you to incorporate into a Process Flow an activity that is not defined within Warehouse Builder. So the User Defined activity brings flexibility and extensibility to Process Flow. In this article, we will take an amazing tour of using the User Defined activity. Let's start. Enable execution of User Defined activity Let's start this section from creating a very simple Process Flow, which contains a Start activity, a User Defined activity and an End Success activity. Leave all parameters of activity USER_DEFINED unchanged except that we enter /tmp/test.sh into the Value column of the COMMAND parameter. Then let's create the shell script test.sh in /tmp directory. Here is the content of /tmp/test.sh (this article is demonstrating a scenario in Linux system, and /tmp/test.sh is a Bash shell script): echo Hello World! > /tmp/test.txt Note: don't forget to grant the execution privilege on /tmp/test.sh to OS Oracle user. For simplicity, we just use the following command. chmod +x /tmp/test.sh OK, it's so simple that we’ve almost done it. Now deploy the Process Flow and run it. For a newly installed OWB, we will come across an error saying "RPE-02248: For security reasons, activity operator Shell has been disabled by the DBA". See below. That's because, by default, the User Defined activity is DISABLED. Configuration about this can be found in <ORACLE_HOME>/owb/bin/admin/Runtime.properties: property.RuntimePlatform.0.NativeExecution.Shell.security_constraint=DISABLED The property can be set to three different values: NATIVE_JAVA, SCHEDULER and DISBALED. Where NATIVE_JAVA uses the Java 'Runtime.exec' interface, SCHEDULER uses a DBMS Scheduler external job submitted by the Control Center repository owner which is executed by the default operating system user configured by the DBA. DISABLED prevents execution via these operators. We enable the execution of User Defined activity by setting: property.RuntimePlatform.0.NativeExecution.Shell.security_constraint= NATIVE_JAVA Restart the Control Center service for the change of setting to take effect. cd <ORACLE_HOME>/owb/rtp/sql sqlplus OWBSYS/<password of OWBSYS> @stop_service.sql sqlplus OWBSYS/<password of OWBSYS> @start_service.sql And then run the Process Flow again. We will see that the Process Flow completes successfully. The execution of /tmp/test.sh successfully generated a file /tmp/test.txt, containing the line Hello World!. Pass parameters to User Defined Activity The Process Flow created in the above section has a drawback: the User Defined activity doesn't accept any information from OWB nor does it give any meaningful results back to OWB. That's to say, it lacks interaction. Maybe, sometimes such a Process Flow can fulfill the business requirement. But for most of the time, we need to get the User Defined activity executed according to some information prior to that step. In this section, we will see how to pass parameters to the User Defined activity and pass them into the to-be-executed shell script. First, let's see how to pass parameters to the script. The User Defined activity has an input parameter named PARAMETER_LIST. This is a list of parameters that will be passed to the command. Parameters are separated from one another by a token. The token is taken as the first character on the PARAMETER_LIST string, and the string must also end in that token. Warehouse Builder recommends the '?' character, but any character can be used. For example, to pass 'abc,' 'def,' and 'ghi' you can use the following equivalent: ?abc?def?ghi? or !abc!def!ghi! or |abc|def|ghi| If the token character or '\' needs to be included as part of the parameter, then it must be preceded with '\'. For example '\\'. If '\' is the token character, then '/' becomes the escape character. Let's configure the PARAMETER_LIST parameter as below: And modify the shell script /tmp/test.sh as below: echo $1 is saying hello to $2! > /tmp/test.txt Re-deploy the Process Flow and run it. We will see that the generated /tmp/test.txt contains the following line: Bob is saying hello to Alice! In the example above, the parameters passed into the shell script are static. This case is not so useful because: instead of passing parameters, we can directly write the value of the parameters in the shell script. To make the case more meaningful, we can pass two dynamic parameters, that are obtained from the previous activity, to the shell script. Prepare the Process Flow as below: The Mapping activity MAPPING_1 has two output parameters: FROM_USER, TO_USER. The User Defined activity has two input parameters: FROM_USER, TO_USER. All the four parameters are of String type. Additionally, the Process Flow has two string variables: VARIABLE_FOR_FROM_USER, VARIABLE_FOR_TO_USER. Through VARIABLE_FOR_FROM_USER, the input parameter FROM_USER of USER_DEFINED gets value from output parameter FROM_USER of MAPPING_1. We achieve this by binding both parameters to VARIABLE_FOR_FROM_USER. See the two figures below. In the same way, through VARIABLE_FOR_TO_USER, the input parameter TO_USER of USER_DEFINED gets value from output parameter TO_USER of MAPPING_1. Also, we need to change the PARAMETER_LIST of the User Defined activity like below: Now, the shell script is getting input from the Mapping activity dynamically. Deploy the Process Flow and all of its necessary dependees then run the Process Flow. We see that the generated /tmp/test.txt contains the following line: USER B is saying hello to USER A! 'USER B' and 'USER A' are two outputs of the Mapping execution. Write the shell script within Oracle Warehouse Builder In the previous section, the shell script is located in the /tmp directory. But sometimes, when the shell script is small, or for the sake of maintaining consistency, you may want to keep the shell script inside Oracle Warehouse Builder. We can achieve this by configuring these three parameters of a User Defined activity properly: COMMAND: Set the path of interpreter, by which the shell script will be interpreted. PARAMETER_LIST: Set it blank. SCRIPT: Enter the shell script content. Note that in Linux the shell script content is passed into the interpreter as standard input at runtime. About how to actually pass parameters to the shell script, we can utilize variable substitutions. As in the following figure, ${FROM_USER} will be replaced by the value of the FROM_USER input parameter of the User Defined activity. So will the ${TO_USER} symbol. Besides the custom substitution variables, OWB also provide some system pre-defined substitution variables. You can refer to the online document for that. Deploy the Process Flow and run it. We see that the generated /tmp/test.txt contains the following line: USER B is saying hello to USER A! Leverage the return value of User Defined activity All of the previous sections are connecting the User Defined activity to END_SUCCESS with an unconditional transition. But what should we do if we want different subsequent activities for different shell script execution results? 1.  The simplest way is to add three simple-conditioned out-going transitions for the User Defined activity just like the figure below. In the figure, to simplify the scenario, we connect the User Defined activity to three End activities. Basically, if the shell script ends successfully, the whole Process Flow will end at END_SUCCESS, otherwise, the whole Process Flow will end at END_ERROR (in our case, ending at END_WARNING seldom happens). In the real world, we can add more complex and meaningful subsequent business logic. 2.  Or we can utilize complex conditions to work with different results of the User Defined activity. Previously, in our script, we only have this line: echo ${FROM_USER} is saying hello to ${TO_USER}! > /tmp/test.txt We can add more logic in it and return different values accordingly. echo ${FROM_USER} is saying hello to ${TO_USER}! > /tmp/test.txt if CONDITION_1 ; then ...... exit 0 fi if CONDITION_2 ; then ...... exit 2 fi if CONDITION_3 ; then ...... exit 3 fi After that we can leverage the result by checking RESULT_CODE in condition expression of those out-going transitions. Let's suppose that we have the Process Flow as the following graph (SUB_PROCESS_n stands for more different further processes): We can set complex condition for the transition from USER_DEFINED to SUB_PROCESS_1 like this: Other transitions can be set in the same way. Note that, in our shell script, we return 0, 2 and 3, but not 1. As in Linux system, if the shell script comes across a system error like IO error, the return value will be 1. We can explicitly handle such a return value. Summary Let's summarize what has been discussed in this article: How to create a Process Flow with a User Defined activity in it How to pass parameters from the prior activity to the User Defined activity and finally into the shell script How to write the shell script within Oracle Warehouse Builder How to do variable substitutions How to let the User Defined activity return different values and in what way can we leverage

    Read the article

  • SOA Suite Integration: Part 2: A basic BPEL process

    - by Anthony Shorten
    This is the next in the series about SOA Suite integration with Oracle Utilities Application Framework. One of the first scenarios I am going to illustrate in this series is building a basic BPEL process using Web Service calls to the Oracle Utilities Application Framework. The scenario is this. I will pass in the userid and the BPEL process will call our the AS-User Web Service we created in Part 1. This is just a basic test and illustrate how to import the Web Service into SOA Suite. To use this scenario, you will need access to Oracle SOA Suite, access to a copy of any Oracle Utilities Application Framework based product and Oracle JDeveloper (to build the process). First of all you need to start Oracle JDeveloper and create a new SOA Project to house the BPEL process in. For the purposes of this example I will call the project simpleBPEL and verify that SOA is part of the project. I will select "Composite with BPEL" to denote it as a BPEL process. I can also the same process to create a Mediator or OSB project (refer to the JDeveloper documentation on these technologies). For this example I will use BPEL 1.1 as my specification standard (BPEL 2.0 can also be used if desired). I give the individual BPEL process as simpleBPEL (you can use a different name but I wanted to keep the project and process the same for this example). I will also build a Synchronous BPEL Process as I want a response from the Web Service. I will leave the defaults to save time. I have no have a blank canvas to build my BPEL process against. Note: for simplicity I am going to use as much defaulting as possible. In fact I am not going to specify an input schema for the incoming call as I will use the basic single field used by BPEL as default. The first step is to import the AS-User Web Service into my BPEL project. To do this I use the standard Web Service BPEL component from the Component Palette to import the WSDL into the BPEL project. Now the tricky part (a joke), you drag and drop the component from the Palette onto the right side of the canvas in the Partner Links swim lane. This swim lane is reserved for Partner Links that have a Partner Role (i.e. being called rather than calling). When you drop the Web Service onto the canvas the Create Web Service wizard is invoked to ask for details of the Web Service. At this point you give the BPEL node a name. I have used the name RetrieveUser as a name. I placed the WSDL URL from the XAI Inbound Service screen in the WSDL URL. Once you specify the URL you can press the Find existing WSDL's button to load the information into BPEL from the call. You will notice the Port Type is prefilled with the port from the WSDL. I also suggest that you check copy wsdl and it's dependent artifacts into the project if you intending to work on the BPEL process offline. If you do not check this your target application must be accessible when you work on the BPEL process (that is not always convenient). Note: For the perceptive of you will notice that the URL specified in this example is different to the URL in the last post. The reason is for the demonstrations I shifted to a new server and did not redo all of the past screen captures. If you copy the WSDL into the project you will get an information screen about Localize Files. It is just a confirmation screen. The last confirmation screen is a summary of the partner link (the main tab is locked for editing at this stage). At this stage you have successfully imported the Web Service. To complete the setup of the Web Service you need to set the credentials for the Web Service to use. Refer to the past post on how to do that. Now to use the Web Service. To call the Web Service (as it is just imported not connected to the BPEL process yet), you must add an Invoke action to your BPEL Process. To do this, select Invoke action from the BPEL Constructs zone on the Component Palette and drop it on the edit nodes between the receiveInput and replyOutput nodes This will create an empty Invoke action. You will notice some connectors on the Invoke node. Grab the node closest to your Web Service and drag it to connect the Invoke to your Web Service. This instructs BPEL to use the Invoke to call the Web Service. Once the Invoke action is connected to the Web Service an Edit Invoke edit dialog is displayed. At this point I suggest you name the Invoke node. It is important to name the nodes straightaway and name them appropriately for you to trace the logic. I used InvokeUser as the name in this example. To complete the node configuration you must create Variables to hold the input and output for the call. To do this clock on Automatically Create Input Variable on the Edit Invoke dialog. You will be presented with a default variable name. It uses the node name (that is why it is important to name the node before hitting this button) as a prefix. You can name the variable anything but I usually take the default. Repeat the same for the output variable. You now have a completed node for invoking the service. You have a very basic BPEL process which contains an input, invoke and output node. It is not complete yet though. You need to tell the BPEL process how to pass data from the input to the invoke step and how to take the output from the service call and pass it back to the service. You need to now add an Assign node to assign the input to the Web Service. To do this select Assign activity from BPEL Constructs zone in the Component Palette. Drag and drop the Assign activity between the receiveInput and InvokeUser nodes as you want to pass data between these two nodes. You have now added a new Assign node to your BPEL process Double clicking the node allows you to specify the name of the node. I use AssignUser to describe that I am assigning user data. On the Copy Rules tab you can specify the mapping between the input variable InputVariable/payload/process/input string and the input variable for the Web Service call. We are passing data from the input to BPEL to the relevant input variable on the Web Service. This is simply drag and drop between the two data structures. In the example, I am using the input to pass to the user element in my Web Service as the user is the primary key for the object. The fields become linked (which means data from source will be copied to target). Almost there. You now need to process the output from the Web Service call to the outputVariable of the client call. I have decided to pass back one piece of data, the name associated with the user by concatenating the firstName and lastName elements from the Web Service call. To do this I will use a Transform as it is not just a matter of an Assign action. It is a concatenation operation. This also illustrates how you can use BPEL functionality to transform data from a Web Service call. As with the other components you drag and drop the Transform component to the appropriate place in the BPEL process. In this case we want to transform the output from the Web Service call so we want it after the InvokeUser action and the replyOutput action. The Transform component is actually part of the Oracle Extensions to the BPEL specification. Double clicking the Transform node will allow you to name the node.  In this example I used TransformName. To complete the transform I need to tell the product the source of the transformation and the target of the transform. In the example this is the InvokeUser output variable. I also named the mapper file to TransformName. By clicking the + or pencil icon next to the map I can create the map. The mapping screen is shows the source and target schemas for me to map across. As with the assign I can map the relevant elements. In my example, I first map the firstName from the Web Service to the result element. As I want to concatenate the names, I drop the concat function on the call line. I now attach the last name to the function to indicate the concatenation of the field. By default the names will be concatenated with no space. To make the name legible I add a space between the field by clicking the function and adding a space in the call. I now have a completed mapping. I can now save the whole project as my BPEL process is now complete. As you can see the following happens: We accept input from the client (the userid for the call) in the receiveInput step. We assign that value to the input parameters for the Web Service call in the AssignUser step. We invoke the Web Service call to retrieve the data from the product in the InvokeUser step. We take the output from the InvokeUser step and concatenate the names in the TransformName step. We pass back the data in the replyOutput step. At this point we can deploy the BPEL process to the SOA Suite server. I will not cover this aspect as it really all SOA Suite specific (it is all done via Oracle JDeveloper). Now we need to test the service in SOA Suite. We will use the Fusion Middleware Control test facility. I will assume that credentials have also been setup as per our previous post (else you will get a 401 error). You navigate to the deployed BPEL process within Fusion Middleware Control and select the Test Service option. Specify some test data on the payload at the bottom of the Test Service screen. In my case I am returning my own userid information. On the response tab you will see the result. It works. You can verify the steps using the Audit trace facility on individual calls. As you can see this is a basic BPEL but you get the idea of importing the Web Service is pretty straightforward. You can create more sophisticated BPEL processes using the full facilities in Oracle SOA Suite. I just showed you the basic principals.

    Read the article

  • How to stop a process in Terminal [closed]

    - by AngryHacker
    Possible Duplicate: Ending a process in unix instead of interrupting it When I task in Terminal, such as ping blah.com, how do I then stop this task (other than closing the Terminal window. In Windows, you can Ctrl+Break pretty much any terminal based process, but I can't figure out the way to do it on the Mac.

    Read the article

< Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >