Search Results

Search found 14773 results on 591 pages for 'smart flash cache'.

Page 15/591 | < Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >

  • Is it OK to set "Cache-Control: public" when sending “304 Not Modified” for images stored in the dat

    - by Emilien
    After asking a question about sending “304 Not Modified” for images stored in the in the Google App Engine datastore, I now have a question about Cache-Control. My app now sends Last-Modified and Etag, but by default GAE alsto sends Cache-Control: no-cache. According to this page: The “no-cache” directive, according to the RFC, tells the browser that it should revalidate with the server before serving the page from the cache. [...] In practice, IE and Firefox have started treating the no-cache directive as if it instructs the browser not to even cache the page. As I DO want browsers to cache the image, I've added the following line to my code: self.response.headers['Cache-Control'] = "public" According to the same page as before: The “cache-control: public” directive [...] tells the browser and proxies [...] that the page may be cached. This is good for non-sensitive pages, as caching improves performance. The question is if this could be harmful to the application in some way? Would it be best to send Cache-Control: must-revalidate to "force" the browser to revalidate (I suppose that is the behavior that was originally the reason behind sending Cache-Control: no-cache) This directive insists that the browser must revalidate the page against the server before serving it from cache. Note that it implicitly lets the browser cache the page.

    Read the article

  • Sprites are sometimes blurry in Flash

    - by Tim Cooper
    I am playing around with drawing an SVG sprite (imported in through [Embed]). Depending on the coordinates of the image, sometimes it appears more crisp than others. The following image shows how at different locations is it rendered differently: (Image link - You may have to download and zoom in with an image editor to see it) You'll notice that the middle sprite is more blurry than the ones on the sides. Does anyone know why this is? Any help would be appreciated.

    Read the article

  • Traffic estimation for a multiplayer flash game

    - by Steve Addington
    hey, i want to know if my rough traffic estimations are right, it would be for a pretty simple realtime flashgame in the style of haxball (but not as a soccer game) heres a video of it http://www.youtube.com/watch?v=z_xBdFg1RcI So here comes my estimation, i dont know if they are realistic! i hope someone can help me. consider the packet attached as a typical one sent every 200ms, its 148bytes + 64 bytes of header will make around a 200bytes packet. The server will receive 200bytes x 6 players x 5 times a sec=6000bytes/s=5.85Kbytes/s=46.9kbit/s plus he has to send all back to the players, so at this point are 94Kbit/s.The server received all the information, perform the definitive calculation and send the new position to all players, in a bigger packet of around 900bytes that have to be delivered to the others 6, which makes 900bytes x 6 players x 5 times a sec=27000bytes/s=26Kbytes/s=210kbit/s. overall that would be 26kbyte per second. thats like 130mb traffic per hour for a 6player room. but somehow i think the numbers are too high? that would be really much traffic for such a simple game. did i calculate something wrong?

    Read the article

  • Box2D Bicycle Wheels Motor Problem - Flash 2.1a

    - by Craig
    I have made a bicycle with Box2D using several polygons for the frame at different angles connected using weld joints, and I have revolute joints on the wheels with a motor. I have made some basic terrain (straight ground and a small ramp) and added keyboard input to control the bicycle with torque to balance it. All of this is done in with Box2D's Debug Draw. When the bicycle is on its back wheel but diagonally forward (kinda like this position - /) the motors just cause it go spinning backwards over when in reality it should either stay on its back wheel or go down onto both wheels. Here's my code the revolute joints: //Front Wheel Joint var frontWheelJointDef:b2RevoluteJointDef = new b2RevoluteJointDef(); frontWheelJointDef.Initialize(frontWheelBody, secondFrameBody, frontWheelBody.GetWorldCenter()); frontWheelJointDef.enableMotor=true; frontWheelJointDef.maxMotorTorque=10000; frontWheelJoint = _world.CreateJoint(frontWheelJointDef) as b2RevoluteJoint; //Rear Wheel Joint var rearWheelJointDef:b2RevoluteJointDef = new b2RevoluteJointDef(); rearWheelJointDef.Initialize(rearWheelBody, firstFrameBody, rearWheelBody.GetWorldCenter()); rearWheelJointDef.enableMotor=true; rearWheelJointDef.maxMotorTorque=10000; rearWheelJoint = _world.CreateJoint(rearWheelJointDef) as b2RevoluteJoint; And here's the relevant part of my update function: // up and down control wheels motor if (up) { motorSpeed-=0.5; } if (down) { motorSpeed += 0.5; } // left and right control cart torque if (left) { middleCentreFrameBody.ApplyTorque( -3); gearBody.ApplyTorque( -3); firstFrameBody.ApplyTorque( -3); secondFrameBody.ApplyTorque( -3); rearWheelToChainBody.ApplyTorque( -3); chainToFrontFrameBody.ApplyTorque( -3); topMiddleFrameBody.ApplyTorque( -3); } if (right) { middleCentreFrameBody.ApplyTorque( 3); gearBody.ApplyTorque( 3); firstFrameBody.ApplyTorque( 3); secondFrameBody.ApplyTorque( 3); rearWheelToChainBody.ApplyTorque( 3); chainToFrontFrameBody.ApplyTorque( 3); topMiddleFrameBody.ApplyTorque( 3); } // motor friction motorSpeed*=0.99; // motor max speed if (motorSpeed>100) { motorSpeed=100; } rearWheelJoint.SetMotorSpeed(motorSpeed); frontWheelJoint.SetMotorSpeed(motorSpeed); Any ideas what might be causing this? Thanks

    Read the article

  • A certain flash application causes a system crash

    - by noobermin
    It's no surprise I guess. Go here to try it! http://www.belgeler.com/blg/2hni/griffiths-introduction-to-electrodynamics-3-ed-solutions-manual It's wonderful, after a few seconds, top shows that our good friend plugin-container takes 83% of the physical memory (8 GB) before everything freezes and the PC doesn't respond. I'm using Ubuntu 12.04 and I have an nvidia (GTS 250) card with the "post-release updates" version of the driver. OFFTOPIC: Yes, it's the solutions manual. I'm self-studying so I don't have a professor to check my work. Please don't judge me :)

    Read the article

  • Flash Webcam non responsive Ubuntu 11.10

    - by powerbuoy
    I've got the same problem as this gentleman: https://answers.launchpad.net/ubuntu/+source/flashplugin-nonfree/+question/176541 Where the webcam settings / access does not work at all / is completely unresponsive in Ubuntu 11.10. I've tried webcam access in Facebook, Google+, my own code + a number of tutorials/demos and none work. What happens is the settings dialogue is completely unresponsive. Clicking tabs or buttons does nothing. In the question linked to a suggested answer is to run Unity 2D. Unfortunately this does not work for me (the exact same thing happens). I've also tried Gnome 3 which also does not work. Note that it is only the webcam settings that don't work. YouTube videos and annoying banners work just fine. Does anyone know of a workaround for this (except going back to 11.04) or if they've fixed this in 12.04? - also, are any of you experiencing the same thing?

    Read the article

  • How can I get shockwave flash to work on Ubuntu 12.04

    - by John Hill
    I've tried most of the things suggested on this site and others so far. It's kind of frustrating because this is a home computer and I mainly use it for browsing the internet and watching YouTube videos. When I try to install something that might fix it, it just downloads a bunch of files and says to extract them or whatever. I'm not sure what to do with the files after I extract them. That's probably the main issue: I don't have a lot of experience working with computers at this level. I'm used to Windows, which seems to make most software installs idiot-proof. Any suggestions are appreciated!!

    Read the article

  • Managing flash animations for a game

    - by LoveMeSomeCode
    Ok, I've been writing C# for a while, but I'm new to ActionScript, so this is a question about best practices. We're developing a simple match game, where the user selects tiles and tries to match various numbers - sort of like memory - and when the match is made we want a series of animations to take place, and when they're done, remove the tile and add a new one. So basically it's: User clicks the MC Animation 1 on the MC starts Animation 1 ends Remove the MC from the stage Add a new MC Start the animation on the new MC The problem I run into is that I don't want to make the same timeline motion tween on each and every tile, when the animation is all the same. It's just the picture in the tile that's different. The other method I've come up with is to just apply the tweens in code on the main stage. Then I attach an event handler for MOTION_FINISH, and in that handler I trigger the next animation and listen for that to finish etc. This works too, but not only do I have to do all the tweening in code, I have a seperate event handler for each stage of the animation. So is there a more structured way of chaining these animations together?

    Read the article

  • Flash Webcam non responsive

    - by powerbuoy
    I've got the same problem as this gentleman: https://answers.launchpad.net/ubuntu/+source/flashplugin-nonfree/+question/176541 Where the webcam settings / access does not work at all / is completely unresponsive in Ubuntu 11.10. I've tried webcam access in Facebook, Google+, my own code + a number of tutorials/demos and none work. What happens is the settings dialogue is completely unresponsive. Clicking tabs or buttons does nothing. In the question linked to a suggested answer is to run Unity 2D. Unfortunately this does not work for me (the exact same thing happens). I've also tried Gnome 3 which also does not work. Note that it is only the webcam settings that don't work. YouTube videos and annoying banners work just fine. Does anyone know of a workaround for this (except going back to 11.04) or if they've fixed this in 12.04? - also, are any of you experiencing the same thing?

    Read the article

  • Macbook 4,1 crashes when flash video (youtube) is played fullscreen (Ubuntu 12.04)

    - by Ydun
    I have searched for similar posts but those were mostly about erratic behaviour. My macbook shuts down instantly without warning when I play a youtube video fullscreen; sometimes after five minutes sometimes longer, never immediately. I can play the video normally for as long as I like, it does not crash, only when played fullscreen. I have tried Firefox and chromium, it crashes with both browsers. Anyone encountered the same thing or has a solution? thanks

    Read the article

  • Squid refresh_pattern won't cache "Expires: ..."

    - by Marcelo Cantos
    Background I frequent the OpenGL ES documentation site at http://www.khronos.org/opengles/sdk/1.1/docs/man/. Even though the content is completely static, it seems to force a reload on every single page I visit, which is very annoying. I have a squid 3.0 proxy set up (apt-get install squid3 on Ubuntu 10.04), and I added a refresh_pattern to force the pages to cache: refresh_pattern ^http://www.khronos.org/opengles/sdk/1\.1/docs/man/ … 1440 20% 10080 … override-expire ignore-reload ignore-no-cache ignore-private ignore-no-store This is all on one line, of course. While this appears to work for the XHTML documents (e.g., glBindTexture), it fails to cache the linked content, such as the DTD, some .ent files (?) and some XSL files. The delay in fetching these extra files delays rendering of the main document, so my principal annoyance isn't fixed. The only difference I can glean with these ancillary files is that they come with an Expires: header set to the current time, whereas the XHTML document has none. But I would have expected the override-expire option to fix this. I have confirmed that documents have the same base URL. I have also truncated the pattern to varying degrees, with no effect. My questions Why does the override-expire option not seem to work? Is there a simple way to tell squid to unconditionally cache a document, no matter what it finds in the response headers? (Hopefully) relevant output cache.log Jan 01 10:33:30 1970/06/25 21:18:27| Processing Configuration File: /etc/squid3/squid.conf (depth 0) Jan 01 10:33:30 1970/06/25 21:18:27| WARNING: use of 'override-expire' in 'refresh_pattern' violates HTTP Jan 01 10:33:30 1970/06/25 21:18:27| WARNING: use of 'ignore-reload' in 'refresh_pattern' violates HTTP Jan 01 10:33:30 1970/06/25 21:18:27| WARNING: use of 'ignore-no-cache' in 'refresh_pattern' violates HTTP Jan 01 10:33:30 1970/06/25 21:18:27| WARNING: use of 'ignore-no-store' in 'refresh_pattern' violates HTTP Jan 01 10:33:30 1970/06/25 21:18:27| WARNING: use of 'ignore-private' in 'refresh_pattern' violates HTTP Jan 01 10:33:30 1970/06/25 21:18:27| DNS Socket created at 0.0.0.0, port 37082, FD 10 Jan 01 10:33:30 1970/06/25 21:18:27| Adding nameserver 192.168.1.1 from /etc/resolv.conf Jan 01 10:33:30 1970/06/25 21:18:27| Accepting HTTP connections at 0.0.0.0, port 3128, FD 11. Jan 01 10:33:30 1970/06/25 21:18:27| Accepting ICP messages at 0.0.0.0, port 3130, FD 13. Jan 01 10:33:30 1970/06/25 21:18:27| HTCP Disabled. Jan 01 10:33:30 1970/06/25 21:18:27| Loaded Icons. Jan 01 10:33:30 1970/06/25 21:18:27| Ready to serve requests. access.log Jun 25 21:19:35 2010.710 0 192.168.1.50 TCP_MEM_HIT/200 2452 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/glBindTexture.xml - NONE/- text/xml Jun 25 21:19:36 2010.263 543 192.168.1.50 TCP_MISS/304 322 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml1-transitional.dtd - DIRECT/74.54.224.215 - Jun 25 21:19:36 2010.276 556 192.168.1.50 TCP_MISS/304 370 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/mathml.xsl - DIRECT/74.54.224.215 - Jun 25 21:19:36 2010.666 278 192.168.1.50 TCP_MISS/304 322 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml-lat1.ent - DIRECT/74.54.224.215 - Jun 25 21:19:36 2010.958 279 192.168.1.50 TCP_MISS/304 322 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml-symbol.ent - DIRECT/74.54.224.215 - Jun 25 21:19:37 2010.251 276 192.168.1.50 TCP_MISS/304 322 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml-special.ent - DIRECT/74.54.224.215 - Jun 25 21:19:37 2010.332 0 192.168.1.50 TCP_IMS_HIT/304 316 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/ctop.xsl - NONE/- text/xml Jun 25 21:19:37 2010.332 0 192.168.1.50 TCP_IMS_HIT/304 316 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/pmathml.xsl - NONE/- text/xml store.log Jun 25 21:19:36 2010.263 RELEASE -1 FFFFFFFF D3056C09B42659631A65A08F97794E45 304 1277464776 -1 1277464776 unknown -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml1-transitional.dtd Jun 25 21:19:36 2010.276 RELEASE -1 FFFFFFFF 9BF7F37442FD84DD0AC0479E38329E3C 304 1277464776 -1 1277464776 unknown -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/mathml.xsl Jun 25 21:19:36 2010.666 RELEASE -1 FFFFFFFF 7BCFCE88EC91578C8E2589CB6310B3A1 304 1277464776 -1 1277464776 unknown -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml-lat1.ent Jun 25 21:19:36 2010.958 RELEASE -1 FFFFFFFF ECF1B24E437CFAA08A2785AA31A042A0 304 1277464777 -1 1277464777 unknown -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml-symbol.ent Jun 25 21:19:37 2010.251 RELEASE -1 FFFFFFFF 36FE3D76C80F0106E6E9F3B7DCE924FA 304 1277464777 -1 1277464777 unknown -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/xhtml-special.ent Jun 25 21:19:37 2010.332 RELEASE -1 FFFFFFFF A33E5A5CCA2BFA059C0FA25163485192 304 1277462871 1221139523 1277462871 text/xml -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/ctop.xsl Jun 25 21:19:37 2010.332 RELEASE -1 FFFFFFFF E2CF8854443275755915346052ACE14E 304 1277462872 1221139523 1277462872 text/xml -1/0 GET http://www.khronos.org/opengles/sdk/1.1/docs/man/pmathml.xsl

    Read the article

  • Help create a unit test for test response header, specifically Cache-Control, in determining if cach

    - by VajNyiaj
    Scenario: I have a base controller which disables caching within the OnActionExecuting override. protected override void OnActionExecuting(ActionExecutingContext filterContext) { filterContext.HttpContext.Response.Cache.SetExpires(DateTime.UtcNow.AddDays(-1)); filterContext.HttpContext.Response.Cache.SetValidUntilExpires(false); filterContext.HttpContext.Response.Cache.SetRevalidation(HttpCacheRevalidation.AllCaches); filterContext.HttpContext.Response.Cache.SetCacheability(HttpCacheability.NoCache); //IE filterContext.HttpContext.Response.Cache.SetNoStore(); //FireFox } How can I create a Unit Test to test this behavior?

    Read the article

  • Clear Asp.Net cache from outside of application (not using source code)

    - by TheJudge
    Hi, I have a asp.net web application and I'm using cache (HttpRuntime.Cache) to save some stuff from db. I also update db from time to time so that data in db does not match the data in my application's cache. Is there any way how to clear my application's cache without modifying any source code or republishing the page? I tried to restart IIS and to clear browsers cache but nothing helps. Please help.

    Read the article

  • Working with the IE cache from C# & WPF

    - by Eric
    I'm writing a program in C# using the WPF framework. I need to display images, and I'd like to cache them to avoid downloading them constantly. I can code my own cache, however, IE already has a caching system. I can find code to read entries out of the IE cache, however I've found nothing dealing with the issue of adding items to the cache. Is there a good way to do it, or should I just implement a separate cache?

    Read the article

  • APC Smart UPS network shutdown issue

    - by Rob Clarke
    Here is a bit about our setup: We have 2x Smart-UPS RT 6000 XL units with network management cards We are running Powerchute from a network server Powerchute is connected to the management cards of both UPSs UPSs are set to do a graceful shutdown via Powerchute when the battery duration is under 20 minutes We also have a command file that runs with Powerchute Although our setup is redundant we do not have an equal load on each server due to APC switches for single power devices The problem is that as we do not have an equal load on each server the batteries drain at different rates. This means that the UPSs both get to the specified low battery duration at completely different times. The problem here is that UPS 1 may have run down to 5 minutes and is in desperate need of initiating a Powerchute shutdown - UPS 2 still has 25 minutes of runtime so no shutdown is initiated. Consequently UPS 1 goes down and takes all the servers with and then shuts down UPS 2 as well! What we need to happen are 1 of either 2 things: Powerchute initiates the shutdown as soon as either UPS reaches the 20 minutes low battery duration setting - and doesnt wait for both The UPS with the heavier load expends its entire battery but does not shutdown both UPSs and lets the load be switched across to the UPS that still has runtime remaining. That way when the UPS that still has runtime reaches its low battery duration it can proceed with the graceful shutdown via Powerchute. Hope that makes sense, any help is greatly appreciated!

    Read the article

  • APC Smart UPS network shutdown issue

    - by Rob Clarke
    Here is a bit about our setup: We have 2x Smart-UPS RT 6000 XL units with network management cards We are running Powerchute from a network server Powerchute is connected to the management cards of both UPSs UPSs are set to do a graceful shutdown via Powerchute when the battery duration is under 20 minutes We also have a command file that runs with Powerchute Although our setup is redundant we do not have an equal load on each server due to APC switches for single power devices The problem is that as we do not have an equal load on each server the batteries drain at different rates. This means that the UPSs both get to the specified low battery duration at completely different times. The problem here is that UPS 1 may have run down to 5 minutes and is in desperate need of initiating a Powerchute shutdown - UPS 2 still has 25 minutes of runtime so no shutdown is initiated. Consequently UPS 1 goes down and takes all the servers with and then shuts down UPS 2 as well! What we need to happen are 1 of either 2 things: Powerchute initiates the shutdown as soon as either UPS reaches the 20 minutes low battery duration setting - and doesnt wait for both The UPS with the heavier load expends its entire battery but does not shutdown both UPSs and lets the load be switched across to the UPS that still has runtime remaining. That way when the UPS that still has runtime reaches its low battery duration it can proceed with the graceful shutdown via Powerchute. Hope that makes sense, any help is greatly appreciated!

    Read the article

  • What is AssetCache and AFCache?

    - by gentmatt
    I'm currently investigating the different locations where the flashplayer in OSX stores its files. The reason is protecting privacy. I've found that Chrome and Firefox both read/write to the following directories: ~/Library/Caches/Adobe/Flash Player/AFCache ~/Library/Caches/Adobe/Flash Player/AssetCache ~/Library/Preferences/Macromedia/Flash Player/#SharedObjects ~/Library/Preferences/Macromedia/Flash Player/macromedia.com/support/flashplayer/sys The last two directories are locations where Firefox stores LSO cookies for long time tracking. You can manually delete them yourself or do this automatically using an extension such as BetterPrivacy for Firefox. However, I have no clue to what the AFCache and AssetCache are for. I assume that you should not delete them as cache generally improves the browsing experience, but I'd really like to know what is stored there? I've been searching the Internet quite a bit now, but there does not seem to be much documentation.

    Read the article

  • Aggregating cache data from OCEP in CQL

    - by Manju James
    There are several use cases where OCEP applications need to join stream data with external data, such as data available in a Coherence cache. OCEP’s streaming language, CQL, supports simple cache-key based joins of stream data with data in Coherence (more complex queries will be supported in a future release). However, there are instances where you may need to aggregate the data in Coherence based on input data from a stream. This blog describes a sample that does just that. For our sample, we will use a simplified credit card fraud detection use case. The input to this sample application is a stream of credit card transaction data. The input stream contains information like the credit card ID, transaction time and transaction amount. The purpose of this application is to detect suspicious transactions and send out a warning event. For the sake of simplicity, we will assume that all transactions with amounts greater than $1000 are suspicious. The transaction history is available in a Coherence distributed cache. For every suspicious transaction detected, a warning event must be sent with maximum amount, total amount and total number of transactions over the past 30 days, as shown in the diagram below. Application Input Stream input to the EPN contains events of type CCTransactionEvent. This input has to be joined with the cache with all credit card transactions. The cache is configured in the EPN as shown below: <wlevs:caching-system id="CohCacheSystem" provider="coherence"/> <wlevs:cache id="CCTransactionsCache" value-type="CCTransactionEvent" key-properties="cardID, transactionTime" caching-system="CohCacheSystem"> </wlevs:cache> Application Output The output that must be produced by the application is a fraud warning event. This event is configured in the spring file as shown below. Source for cardHistory property can be seen here. <wlevs:event-type type-name="FraudWarningEvent"> <wlevs:properties type="tuple"> <wlevs:property name="cardID" type="CHAR"/> <wlevs:property name="transactionTime" type="BIGINT"/> <wlevs:property name="transactionAmount" type="DOUBLE"/> <wlevs:property name="cardHistory" type="OBJECT"/> </wlevs:properties </wlevs:event-type> Cache Data Aggregation using Java Cartridge In the output warning event, cardHistory property contains data from the cache aggregated over the past 30 days. To get this information, we use a java cartridge method. This method uses Coherence’s query API on credit card transactions cache to get the required information. Therefore, the java cartridge method requires a reference to the cache. This may be set up by configuring it in the spring context file as shown below: <bean class="com.oracle.cep.ccfraud.CCTransactionsAggregator"> <property name="cache" ref="CCTransactionsCache"/> </bean> This is used by the java class to set a static property: public void setCache(Map cache) { s_cache = (NamedCache) cache; } The code snippet below shows how the total of all the transaction amounts in the past 30 days is computed. Rest of the information required by CardHistory object is calculated in a similar manner. Complete source of this class can be found here. To find out more information about using Coherence's API to query a cache, please refer Coherence Developer’s Guide. public static CreditHistoryData(String cardID) { … Filter filter = QueryHelper.createFilter("cardID = :cardID and transactionTime :transactionTime", map); CardHistoryData history = new CardHistoryData(); Double sum = (Double) s_cache.aggregate(filter, new DoubleSum("getTransactionAmount")); history.setTotalAmount(sum); … return history; } The java cartridge method is used from CQL as seen below: select cardID, transactionTime, transactionAmount, CCTransactionsAggregator.execute(cardID) as cardHistory from inputChannel where transactionAmount1000 This produces a warning event, with history data, for every credit card transaction over $1000. That is all there is to it. The complete source for the sample application, along with the configuration files, is available here. In the sample, I use a simple java bean to load the cache with initial transaction history data. An input adapter is used to create and send transaction events for the input stream.

    Read the article

  • The clock hands of the buffer cache

    - by Tony Davis
    Over a leisurely beer at our local pub, the Waggon and Horses, Phil Factor was holding forth on the esoteric, but strangely poetic, language of SQL Server internals, riddled as it is with 'sleeping threads', 'stolen pages', and 'memory sweeps'. Generally, I remain immune to any twinge of interest in the bowels of SQL Server, reasoning that there are certain things that I don't and shouldn't need to know about SQL Server in order to use it successfully. Suddenly, however, my attention was grabbed by his mention of the 'clock hands of the buffer cache'. Back at the office, I succumbed to a moment of weakness and opened up Google. He wasn't lying. SQL Server maintains various memory buffers, or caches. For example, the plan cache stores recently-used execution plans. The data cache in the buffer pool stores frequently-used pages, ensuring that they may be read from memory rather than via expensive physical disk reads. These memory stores are classic LRU (Least Recently Updated) buffers, meaning that, for example, the least frequently used pages in the data cache become candidates for eviction (after first writing the page to disk if it has changed since being read into the cache). SQL Server clearly needs some mechanism to track which pages are candidates for being cleared out of a given cache, when it is getting too large, and it is this mechanism that is somewhat more labyrinthine than I previously imagined. Each page that is loaded into the cache has a counter, a miniature "wristwatch", which records how recently it was last used. This wristwatch gets reset to "present time", each time a page gets updated and then as the page 'ages' it clicks down towards zero, at which point the page can be removed from the cache. But what is SQL Server is suffering memory pressure and urgently needs to free up more space than is represented by zero-counter pages (or plans etc.)? This is where our 'clock hands' come in. Each cache has associated with it a "memory clock". Like most conventional clocks, it has two hands; one "external" clock hand, and one "internal". Slava Oks is very particular in stressing that these names have "nothing to do with the equivalent types of memory pressure". He's right, but the names do, in that peculiar Microsoft tradition, seem designed to confuse. The hands do relate to memory pressure; the cache "eviction policy" is determined by both global and local memory pressures on SQL Server. The "external" clock hand responds to global memory pressure, in other words pressure on SQL Server to reduce the size of its memory caches as a whole. Global memory pressure – which just to confuse things further seems sometimes to be referred to as physical memory pressure – can be either external (from the OS) or internal (from the process itself, e.g. due to limited virtual address space). The internal clock hand responds to local memory pressure, in other words the need to reduce the size of a single, specific cache. So, for example, if a particular cache, such as the plan cache, reaches a defined "pressure limit" the internal clock hand will start to turn and a memory sweep will be performed on that cache in order to remove plans from the memory store. During each sweep of the hands, the usage counter on the cache entry is reduced in value, effectively moving its "last used" time to further in the past (in effect, setting back the wrist watch on the page a couple of hours) and increasing the likelihood that it can be aged out of the cache. There is even a special Dynamic Management View, sys.dm_os_memory_cache_clock_hands, which allows you to interrogate the passage of the clock hands. Frequently turning hands equates to excessive memory pressure, which will lead to performance problems. Two hours later, I emerged from this rather frightening journey into the heart of SQL Server memory management, fascinated but still unsure if I'd learned anything that I'd put to any practical use. However, I certainly began to agree that there is something almost Tolkeinian in the language of the deep recesses of SQL Server. Cheers, Tony.

    Read the article

  • Accenture Launches Smart Grid Data Management Platform

    - by caroline.yu
    Accenture announced today it has launched the Accenture Intelligent Network Data Enterprise (INDE), a data management platform to help utilities design, deploy and manage smart grids. INDE's functionality can be enabled by an array of third party technologies. In addition, Accenture plans to offer utilities the option of implementing the INDE solution based on a pre-configured suite of Oracle technologies. The Oracle-based version of INDE will accelerate the design of smart grids and help reduce the costs and risks associated with smart grid implementation. Stephan Scholl, Senior Vice President and General Manager of Oracle Utilities said, "Oracle and Accenture share a common vision of how the smart grid will enable more efficient energy choices for utilities and their customers. Our combined expertise in delivering mission-critical smart grid applications, security, data management and systems integration can help accelerate utilities toward a more intelligent network now and as future needs arise." For the full press release, click here.

    Read the article

  • Opera Mini 7 launch to turn Java ME phones into smart browser phones

    - by hinkmond
    Here's a good way to smarten up your Java ME smart-challenged phone. Use the new Opera Mini 7 browser to view your personalized "Smart Page". See: Opera Mini 7 w/Java ME Here's a quote: The browser comes with a new feature called 'Smart Page'... a one-page summary of all the news from your Facebook and Twitter feeds. In addition to showing your friends' status updates and tweets, Smart Page will offer up suggestions for news sites to follow, and... save you the hassle of manually typing Web addresses into your mobile keyboard. ... Opera Mini 7 is available as a free download for Java-compatible (J2ME), Nokia S60, and Blackberry devices at m.opera.com That's smart! Using Java ME means you don't have to deal with those other platforms. Hinkmond

    Read the article

  • Hyperion Smart View Assistance

    - by p.anda
    (in via Akhter) Seeking more information or assistance with Hyperion Smart View?  The Oracle Technology Network (OTN) is a great first place to "stop-by".  Here the site provides access to the latest installer, general product documentation as well as Whitepapers, "Whats New" and "Oracle by Example" tutorials: OTN: Overview | Downloads | Documentation | Tutorials  For the latest documentation including Readme, New Features, User's Guide, Developer's Guide and Accessibility Guide visit: Oracle Hyperion Smart View for Office Documentation Release 11.1.2.5 Several "My Oracle Support" Knowledge (KM) Articles are available including: OBIEE 11.1.1.7 - New Features And Recommendations For Working With Microsoft Office [ Doc ID 1558070.1]- How to Integrate OBIEE with Microsoft Office Using Oracle Hyperion Smart View For Office [ Doc ID 1576336.1] - How To Create New Report From Scratch Within Excel Using Smart View [ Doc ID 1576596.1] These along with additional KM articles are being indexed in a Master Note - to keep up to-date with new articles bookmark this index page at: Master Note For Oracle Hyperion Smart View For Office Issues in OBIEE Doc ID 1589028.1

    Read the article

  • Smart way to execute function in flash from an imported html (or XML) plain text

    - by DomingoSL
    Ok, here is the think. I have a very simple flash program code in AS3, inside this program there is a dynamic textfield html capable. Also i have a database were i will put some information. Each element in the database can be linked to other. For example, this database will contain tourist spots, and they can be related with others in the same database. Ramdom place 1 This interesting spot is near <link to="ramdo2">ramdom place2</link>. And so, so so... The information in the database is retrived by the flash application and it shows the text on the dynamic textfield. I need somehow to tell my flash application that have to be a link to other part of the database, so when the user click the link a function in flash call this new data. The database is a simple Mysql server, and the data is not yet in there, waiting for your suggestions of how to format it and develop the solution. Im a php developer too, so i can make a gateway in PHP to read the MySQL and then retrive some format to flash, an XML for example.

    Read the article

  • Disable linux read and write file cache on partition

    - by complistic
    How do i disable the linux file cache on a xfs partition (both read an write). We have a xfs partition over a hardware RAID that stores our RAW HD Video. Most of the shoots are 50-300gb each so the linux cache has a hit-rate of 0.001%. I have tryed the sync option but it still fills up the cache when copinging the files. ( about 30x over per shoot :P ) /etc/fstab: /dev/sdb1 /video xfs sync,noatime,nodiratime,logbufs=8 0 1 Im running debian lenny if it helps.

    Read the article

< Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >