Search Results

Search found 860 results on 35 pages for 'strip'.

Page 15/35 | < Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >

  • Is a display list best for this? (OpenGL)

    - by user146780
    I'm rendering 2D polygons with the GLUTesselator the first time, then they are stored in a display list for subsequent use. I think VBO's might be faster, but since I can't access the stuff that the tesselator outputs, and since it uses mixes of gl_triangle, quad, strip etc, i'm not sure how I could do this, even though I would like to use VBO's once the GLUTesselator is done with them for optimal performance. Thanks

    Read the article

  • AviSaveOptions() dialog window is distorted!

    - by Roey
    Hi All. I'm using windows XP , hebrew version. I am trying to save an AVI file using the Video For Windows API in C++, when I run the AviSaveOptions() function, the dialog opens as a thin unclickable strip at the corner of the screen. Would it have anything to do with the language (Hebrew)? maybe with the vfw driver itself? what might cause a windows dialog window to be distorted/invisible? thanks Roey

    Read the article

  • Unable to get set intersection to work

    - by chavanak
    Sorry for the double post, I will update this question if I can't get things to work :) I am trying to compare two files. I will list the two file content: File 1 File 2 "d.complex.1" "d.complex.1" 1 4 5 5 48 47 65 21 d.complex.10 d.complex.10 46 6 21 46 109 121 192 192 TI am trying to compare the contents of the two file but not in a trivial way. I will explain what I want with an example. If you observe the file content I have typed above, the d.complex.1 of file_1 has "5" similar to d.complex.1 in file_2; the same d.complex.1 in file_1 has nothing similar to d.complex.10 in file_2. What I am trying to do is just to print out those d.complex. which has nothing in similar with the other d.complex. Consider the d.complex. as a heading if you want. But all I am trying is compare the numbers below each d.complex. and if nothing matches, I want that particular d.complex. from both files to be printed. If even one number is present in both d.complex. of both files, I want it to be rejected. My Code: The method I chose to achieve this was to use sets and then do a difference. Code I wrote was: first_complex=open( "file1.txt", "r" ) first_complex_lines=first_complex.readlines() first_complex_lines=map( string.strip, first_complex_lines ) first_complex.close() second_complex=open( "file2.txt", "r" ) second_complex_lines=second_complex.readlines() second_complex_lines=map( string.strip, second_complex_lines ) second_complex.close() list_1=[] list_2=[] res_1=[] for line in first_complex_lines: if line.startswith( "d.complex" ): res_1.append( [] ) res_1[-1].append( line ) res_2=[] for line in second_complex_lines: if line.startswith( "d.complex" ): res_2.append( [] ) res_2[-1].append( line ) h=len( res_1 ) k=len( res_2 ) for i in res_1: for j in res_2: print i[0] print j[0] target_set=set ( i ) target_set_1=set( j ) for s in target_set: if s not in target_set_1: if s[0] != "d": print s The above code is giving an output like this (just an example): d.complex.1.dssp d.complex.1.dssp 1 48 65 d.complex.1.dssp d.complex.10.dssp 46 21 109 What I would like to have is: d.complex.1 d.complex.1 (name from file2) d.complex.1 d.complex.10 (name from file2) I am sorry for confusing you guys, but this is all that is required. I am so new to python so my concept above might be flawed. Also I have never used sets before :(. Can someone give me a hand here?

    Read the article

  • Making a grid on iPhone using Opengl

    - by TheGambler
    I'm trying to make a grid similar to what you would see in these geo games(geoDefense/geometry wars). I'm wanting to apply separate transformation matrixes to each to create different effects. So, it makes since to me that I need to draw each square separately to that I can apply a different transformation to each one. The problem I'm having is mapping these grids out or connecting the squares. The coordinate systems is still confusing to me. I know it would be easy just to create a huge triangle strip but I'm not able to figure out a way to apply separate transformations to each square( quad ) if I use triangle strips. So first question: Can you apply different transformations to quads if you use a triangle strip to draw a huge grid? If so, any tips suggestions on how to do so? If not, how does one usually connect textures without using triangle strips? Here is my coord setup: const GLfloat zNear = 0.01, zFar = 1000.0, fieldOfView = 45.0; GLfloat size; glEnable(GL_DEPTH_TEST); glMatrixMode(GL_PROJECTION); size = zNear * tanf(DEGREES_TO_RADIANS(fieldOfView) / 2.0); CGRect rect = view.bounds; glFrustumf(-size, size, -size / (rect.size.width / rect.size.height), size / (rect.size.width / rect.size.height), zNear, zFar); glViewport(0, 0, rect.size.width, rect.size.height); Here is my draw: - (void)drawView:(GLView*)view; { int loop; //glColor4f(1.0, 1.0, 1.0, 0.5); glClear(GL_COLOR_BUFFER_BIT | GL_DEPTH_BUFFER_BIT); //Grid Loop for( loop = 0; loop < kNumberSectionsInGrid; loop++ ) { //glLoadIdentity(); static Matrix3D shearMatrix; Matrix3DSetShear(shearMatrix, 0.2, 0.2); static Matrix3D finalMatrix; //Matrix3DMultiply(temp2Matrix, shearMatrix, finalMatrix); glLoadMatrixf(shearMatrix); glTranslatef(-1.0f,(float)loop,-3.0f); glScalef(0.1, 0.1, 0.0); Vertex3D vertices[] = { {-1.0, 1.0, 0.5}, { 1.0, 1.0, 0.5}, { -1.0, -1.0, 0.5}, { 1.0, -1.0, 0.5} }; static const Vector3D normals[] = { {0.0, 0.0, 1.0}, {0.0, 0.0, 1.0}, {0.0, 0.0, 1.0}, {0.0, 0.0, 1.0}, }; GLfloat texCoords[] = { 0.0, 1.0, 1.0, 1.0, 0.0, 0.0, 1.0, 0.0 }; glEnableClientState(GL_VERTEX_ARRAY); glEnableClientState(GL_NORMAL_ARRAY); glEnableClientState(GL_TEXTURE_COORD_ARRAY); glBindTexture(GL_TEXTURE_2D, texture[0]); glVertexPointer(3, GL_FLOAT, 0, vertices); glNormalPointer(GL_FLOAT, 0, normals); glTexCoordPointer(2, GL_FLOAT, 0, texCoords); glDrawArrays(GL_TRIANGLE_STRIP, 0, 4); glDisableClientState(GL_VERTEX_ARRAY); glDisableClientState(GL_NORMAL_ARRAY); glDisableClientState(GL_TEXTURE_COORD_ARRAY); } } glMatrixMode(GL_MODELVIEW);

    Read the article

  • mod_rewrite to make a short URL

    - by Chris Stewart
    I have a url like: http://skepticalgamer.com/category/slam-the-controller I'd like to strip out "category" from the URL. So I'd want: http://skepticalgamer.com/slam-the-controller to act as if it were the original URL above. Is that something that can be done with mod_rewrite?

    Read the article

  • removing <br/> from GET request

    - by tking
    I'm using a get request to get some page data but need to strip the break tags from the finished file. Basically what I'm doing is taking the output of the get request and saving it to a file but it has hundereds of break tags in it I need removed. I'm fine with running a batch or vb script after the file is saved to remove the tags but I'm not sure how on how to do that either. So far the only solutions I have seen is to remove entire lines.

    Read the article

  • get premitive , complex, ArrayEnumerable types

    - by john
    i have a separate class for each of my database entities and when i create an object of my class to reference the properties of a class it returns a circular reference which contains properties of other entities too that are related via FK ... to remove the circular reference i want to first make a copy of the object through "context proxy object" copy and then get the primitive, complex, arrayEnumerable types of that object and strip off these types from the object and then the object get returned by web service....

    Read the article

  • Dedicated hard disk for SE dbname.dbs files & dedicated ramdisk for /tmp files.

    - by Frank Computer
    INFORMIX-SE 7.2: I would like to dedicate a hard disk, exclusively for my dbname.dbs directory which holds all the .dat and .idx files, and create a ramdisk for my /tmp temporary files in order to improve performance. I would also like to strip down the OS from any unecessary files and processes to minimize overhead for my dedicated application. Is this a good idea and are there any roadmaps for accomplishing this?

    Read the article

  • Are python list comprehensions always a good programming practice?

    - by dln385
    To make the question clear, I'll use a specific example. I have a list of college courses, and each course has a few fields (all of which are strings). The user gives me a string of search terms, and I return a list of courses that match all of the search terms. This can be done in a single list comprehension or a few nested for loops. Here's the implementation. First, the Course class: class Course: def __init__(self, date, title, instructor, ID, description, instructorDescription, *args): self.date = date self.title = title self.instructor = instructor self.ID = ID self.description = description self.instructorDescription = instructorDescription self.misc = args Every field is a string, except misc, which is a list of strings. Here's the search as a single list comprehension. courses is the list of courses, and query is the string of search terms, for example "history project". def searchCourses(courses, query): terms = query.lower().strip().split() return tuple(course for course in courses if all( term in course.date.lower() or term in course.title.lower() or term in course.instructor.lower() or term in course.ID.lower() or term in course.description.lower() or term in course.instructorDescription.lower() or any(term in item.lower() for item in course.misc) for term in terms)) You'll notice that a complex list comprehension is difficult to read. I implemented the same logic as nested for loops, and created this alternative: def searchCourses2(courses, query): terms = query.lower().strip().split() results = [] for course in courses: for term in terms: if (term in course.date.lower() or term in course.title.lower() or term in course.instructor.lower() or term in course.ID.lower() or term in course.description.lower() or term in course.instructorDescription.lower()): break for item in course.misc: if term in item.lower(): break else: continue break else: continue results.append(course) return tuple(results) That logic can be hard to follow too. I have verified that both methods return the correct results. Both methods are nearly equivalent in speed, except in some cases. I ran some tests with timeit, and found that the former is three times faster when the user searches for multiple uncommon terms, while the latter is three times faster when the user searches for multiple common terms. Still, this is not a big enough difference to make me worry. So my question is this: which is better? Are list comprehensions always the way to go, or should complicated statements be handled with nested for loops? Or is there a better solution altogether?

    Read the article

  • Python script to remove lines from file containing words in array

    - by chromesub
    I have the following script which identifies lines in a file which I want to remove, based on an array but does not remove them. What should I change? sourcefile = "C:\\Python25\\PC_New.txt" filename2 = "C:\\Python25\\PC_reduced.txt" offending = ["Exception","Integer","RuntimeException"] def fixup( filename ): print "fixup ", filename fin = open( filename ) fout = open( filename2 , "w") for line in fin.readlines(): for item in offending: print "got one",line line = line.replace( item, "MUST DELETE" ) line=line.strip() fout.write(line) fin.close() fout.close() fixup(sourcefile)

    Read the article

  • Named pipe is using 100% CPU

    - by willwill
    I'm starting the script with ./file.py < pipe >> logfile and the script is: while True: try: I = raw_input().strip().split() except EOFError: continue doSomething() How could I better handle named pipe? This script always run at 100% CPU and it need to be real-time so I cannot use time.sleep.

    Read the article

  • Why can't I build Deluge?

    - by hugemeow
    Deluge is a BitTorrent Client. I am trying to build it from source, since I don't have privilege to install it as root. I am using python setup.py build. But, it failed following message, why? copying deluge/ui/web/themes/images/gray/slider/slider-v-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/slider copying deluge/ui/web/themes/images/gray/slider/slider-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/slider copying deluge/ui/web/themes/images/gray/panel/top-bottom.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/panel copying deluge/ui/web/themes/images/gray/tabs/tab-strip-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/tabs copying deluge/ui/web/themes/images/yourtheme/window/right-corners.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window copying deluge/ui/web/themes/images/yourtheme/window/left-corners.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window copying deluge/ui/web/themes/images/yourtheme/window/left-right.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window copying deluge/ui/web/themes/images/yourtheme/window/top-bottom.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window creating build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-v-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-v-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/panel/top-bottom.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/panel copying deluge/ui/web/themes/images/yourtheme/grid/hmenu-lock.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/grid copying deluge/ui/web/themes/images/yourtheme/grid/hmenu-unlock.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/grid copying deluge/ui/web/themes/images/yourtheme/tabs/tab-strip-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/tabs running build_ext building 'libtorrent' extension gcc -pthread -shared -L/usr/lib64 -L/opt/local/lib -lboost_filesystem -lboost_date_time -lboost_iostreams -lboost_python -lboost_thread -lpthread -lssl -lz -o build/lib.linux-x86_64-2.4/deluge/libtorrent.so /usr/bin/ld: cannot find -lboost_filesystem collect2: ld returned 1 exit status error: command 'gcc' failed with exit status 1 [mirror@innov deluge-1.3.5]$ echo $? 1 Edit 1: gcc version and os information $(which gcc) --version gcc (GCC) 4.1.2 20080704 (Red Hat 4.1.2-52) Copyright (C) 2006 Free Software Foundation, Inc. This is free software; see the source for copying conditions. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. cat /etc/issue CentOS release 5.7 (Final) Kernel \r on an \m Edit 2: boost is referenced by setup.py in deluge 114 if OS == "linux": 115 if os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 116 'libboost_filesystem-mt.so')): 117 boost_filesystem = "boost_filesystem-mt" 118 elif os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 119 'libboost_filesystem.so')): 120 boost_filesystem = "boost_filesystem" 121 if os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 122 'libboost_date_time-mt.so')): 123 boost_date_time = "boost_date_time-mt" 124 elif os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 125 'libboost_date_time.so')): 126 boost_date_time = "boost_date_time" 127 if os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 128 'libboost_thread-mt.so')): 129 boost_thread = "boost_thread-mt" 130 elif os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 131 'libboost_thread.so')): 132 boost_thread = "boost_thread" 133 134 if 'boost_filesystem' not in vars(): 135 boost_filesystem = "boost_filesystem-mt" 136 if 'boost_date_time' not in vars(): 137 boost_date_time = "boost_date_time-mt" 138 if 'boost_thread' not in vars(): 139 boost_thread = "boost_thread-mt" 140 141 elif OS == "freebsd": 142 boost_filesystem = "boost_filesystem" 143 boost_date_time = "boost_date_time" 144 boost_thread = "boost_thread" 145 else: 146 boost_filesystem = "boost_filesystem-mt" 147 boost_date_time = "boost_date_time-mt" 148 boost_thread = "boost_thread-mt" 149 150 librariestype = [boost_filesystem, boost_date_time, 151 boost_thread, 'z', 'pthread', 'ssl', 'crypto']

    Read the article

  • How to export computers from Active Directory to XML using Powershell?

    - by CoDeRs
    I am trying to create a powershell scripts for Remote Desktop Connection Manager using the active directory module. My first thought was get a list of computers in AD and parse them out into XML format similar to the OU structure that is in AD. I have no problem with that, the below code will work just but not how I wanted. EG # here is a the array $OUs Americas/Canada/Canada Computers/Desktops Americas/Canada/Canada Computers/Laptops Americas/Canada/Canada Computers/Virtual Computers Americas/USA/USA Computers/Laptops Computers Disabled Accounts Domain Controllers EMEA/UK/UK Computers/Desktops EMEA/UK/UK Computers/Laptops Outside Sales and Service/Laptops Servers I wanted to have the basic XML structured like this Americas Canada Canada Computers Desktops Laptops Virtual Computers USA USA Computers Laptops Computers Disabled Accounts Domain Controllers EMEA UK UK Computers Desktops Laptops Outside Sales and Service Laptops Servers However if you run the below it does not nest the next string in the array it only restarts the from the beginning and duplicating Americas Canada Canada Computers Desktops Americas Canada Canada Computers Laptops Americas Canada Canada Computers Virtual Computers Americas USA USA Computers Laptops RDCMGenerator.ps1 #Importing Microsoft`s PowerShell-module for administering ActiveDirectory Import-Module ActiveDirectory #Initial variables $OUs = @() $RDCMVer = "2.2" $userName = "domain\username" $password = "Hashed Password+" $Path = "$env:temp\test.xml" $allComputers = Get-ADComputer -LDAPFilter "(OperatingSystem=*)" -Properties Name,Description,CanonicalName | Sort-Object CanonicalName | select Name,Description,CanonicalName $allOUObjects = $allComputers | Foreach {"$($_.CanonicalName)"} Function Initialize-XML{ ##<RDCMan schemaVersion="1"> $xmlWriter.WriteStartElement('RDCMan') $XmlWriter.WriteAttributeString('schemaVersion', '1') $xmlWriter.WriteElementString('version',$RDCMVer) $xmlWriter.WriteStartElement('file') $xmlWriter.WriteStartElement('properties') $xmlWriter.WriteElementString('name',$env:userdomain) $xmlWriter.WriteElementString('expanded','true') $xmlWriter.WriteElementString('comment','') $xmlWriter.WriteStartElement('logonCredentials') $XmlWriter.WriteAttributeString('inherit', 'None') $xmlWriter.WriteElementString('userName',$userName) $xmlWriter.WriteElementString('domain',$env:userdomain) $xmlWriter.WriteStartElement('password') $XmlWriter.WriteAttributeString('storeAsClearText', 'false') $XmlWriter.WriteRaw($password) $xmlWriter.WriteEndElement() $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('connectionSettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('gatewaySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('remoteDesktop') $XmlWriter.WriteAttributeString('inherit', 'None') $xmlWriter.WriteElementString('size','1024 x 768') $xmlWriter.WriteElementString('sameSizeAsClientArea','True') $xmlWriter.WriteElementString('fullScreen','False') $xmlWriter.WriteElementString('colorDepth','32') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('localResources') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('securitySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('displaySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteEndElement() } Function Create-Group ($groupName){ #Start Group $xmlWriter.WriteStartElement('properties') $xmlWriter.WriteElementString('name',$groupName) $xmlWriter.WriteElementString('expanded','true') $xmlWriter.WriteElementString('comment','') $xmlWriter.WriteStartElement('logonCredentials') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('connectionSettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('gatewaySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('remoteDesktop') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('localResources') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('securitySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('displaySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteEndElement() } Function Create-Server ($computerName, $computerDescription) { #Start Server $xmlWriter.WriteStartElement('server') $xmlWriter.WriteElementString('name',$computerName) $xmlWriter.WriteElementString('displayName',$computerDescription) $xmlWriter.WriteElementString('comment','') $xmlWriter.WriteStartElement('logonCredentials') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('connectionSettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('gatewaySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('remoteDesktop') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('localResources') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('securitySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteStartElement('displaySettings') $XmlWriter.WriteAttributeString('inherit', 'FromParent') $xmlWriter.WriteEndElement() $xmlWriter.WriteEndElement() #Stop Server } Function Close-XML { $xmlWriter.WriteEndElement() $xmlWriter.WriteEndElement() # finalize the document: $xmlWriter.Flush() $xmlWriter.Close() notepad $path } #Strip out Domain and Computer Name from CanonicalName foreach($OU in $allOUObjects){ $newSplit = $OU.split("/") $rebildOU = "" for($i=1; $i -le ($newSplit.count - 2); $i++){ $rebildOU += $newSplit[$i] + "/" } $OUs += $rebildOU.substring(0,($rebildOU.length - 1)) } #Remove Duplicate OU's $OUs = $OUs | select -uniq #$OUs # get an XMLTextWriter to create the XML $XmlWriter = New-Object System.XMl.XmlTextWriter($Path,$UTF8) # choose a pretty formatting: $xmlWriter.Formatting = 'Indented' $xmlWriter.Indentation = 1 $XmlWriter.IndentChar = "`t" # write the header $xmlWriter.WriteStartDocument() # # 'encoding', 'utf-8' How? # # set XSL statements #Initialize Pre-Defined XML Initialize-XML ######################################################### # Start Loop for each OU-Path that has a computer in it ######################################################### foreach ($OU in $OUs){ $totalGroupName = "" #Create / Reset Total OU-Path Completed $OU.split("/") | foreach { #Split the OU-Path into individual OU's $groupName = "$_" #Current OU $totalGroupName += $groupName + "/" #Total OU-Path Completed $xmlWriter.WriteStartElement('group') #Start new XML Group Create-Group $groupName #Call function to create XML Group ################################################ # Start Loop for each Computer in $allComputers ################################################ foreach($computer in $allComputers){ $computerOU = $computer.CanonicalName #Set the computers OU-Path $OUSplit = $computerOU.split("/") #Create the Split for the OU-Path $rebiltOU = "" #Create / Reset the stripped OU-Path for($i=1; $i -le ($OUSplit.count - 2); $i++){ #Start Loop for OU-Path to strip out the Domain and Computer Name $rebiltOU += $OUSplit[$i] + "/" #Rebuild the stripped OU-Path } if ($rebiltOU -eq $totalGroupName){ #Compare the Current OU-Path with the computers stripped OU-Path $computerName = $computer.Name #Set the computer name $computerDescription = $computerName + " - " + $computer.Description #Set the computer Description Create-Server $computerName $computerDescription #Call function to create XML Server } } } ################################################### # Start Loop to close out XML Groups created above ################################################### $totalGroupName.split("/") | foreach { #Split the if ($_ -ne "" ){ $xmlWriter.WriteEndElement() #End Group } } } Close-XML

    Read the article

  • How to restore Linode to Vagrant VM?

    - by Iain Elder
    I'm trying to set up a Linux development environment so I can safely make changes to my website without breaking the live site. Linode hosts my live site. A simple solution would be to host my development server on Linode as well, but I want to avoid doubling my hosting costs. The cheapest way I see is to use Vagrant on my Windows workstation to host my development environment. After I attempt to restore the backup to Vagrant and reboot the VM, I can no longer ssh into the Vagrant host. It's probably because by restoring the backup I overwrite some special Vagrant configuration, but I'm not sure how to avoid that. How do I make this approach work? If my approach is fundamentally wrong, can you suggest an alternative? Creating the backup On the Linode I used these commands to create a compressed copy of the entire filesystem, while ignoring things that shouldn't be included in the backup: $ sudo rsync -ahvz --exclude={/dev/*,/proc/*,/sys/*,/tmp/*,/run/*,/mnt/*,/backup/*} /* /backup/2 $ sudo tar -czf /backup/2.gz /backup/2 The backup file is called 2.gz because this is thesecond backup. The first backup is called 1.gz. I use WinSCP to copy the backup file to my Windows workstation. Setting up the Vagrant host I need a Vagrant box that matches my Linode operating system (Ubuntu 12.04.3 LTS, kernel 3.9.3). I selected the closet match from vagrantbox.es: Ubuntu Server Precise 12.04.3 amd64 Kernel is ready for Docker (Docker not included) On my workstation I ran these commands to add the box and initialize and boot an instance: $ vagrant box add ubuntu-precise http://nitron-vagrant.s3-website-us-east-1.amazonaws.com/vagrant_ubuntu_12.04.3_amd64_virtualbox.box $ mkdir linode-test $ cd linode-test $ vagrant init ubuntu-precise $ vagrant up Now Vagrant is running a machine with SSH on port 2222. The operating system version is the same. The kernel version is 3.8.0. Sounds close enough. Restoring the backup With WinSCP I copied the backup file 2.gz to /home/vagrant/2.gz on the Vagrant box. With PuTTY I connected via ssh to my new Vagrant box: On the box move the backup to the filesystem root. $ sudo mv 2.gz / Extract the archive to the filesystem root: $ sudo tar -xvpz -f 2.gz -C / --strip-components=2 (I discovered I need to use strip components because all files in the archive have the prefix backup/2/. I'll fix this for the next backup.) After the tar command completes, I log out of the box. Testing the backup When I try to log in again, it doesn't let me log in as vagrant with a password any more. It does let me log in as iain, my user on the live Linode, with a password. That surprised me because I disabled password authentication on my live Linode. I figured that I have to restart the ssh service for the change to take effect. Instead of restarting just ssh, I chose to restart the whole system. Now I can't even get to the login screen. PuTTY says "connection refused" when I try to connect. What went wrong?

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Mod_Rewrite w Apache mod_jrun22.so & ColdFusion 9 on cPanel

    - by Eddie B
    How can I utilize mod_rewrite at either the httpd.conf level or per-directory level when mod_jrun22 seems to have short-stopped the rewrite process for ColdFusion pages? I have a ColdFusion 9 based site running on Centos 5.8 w cPanel. cPanel uses EasyApache 3 to manage virtual host containers and as such the conf for mod_jrun22.so, /usr/local/apache/conf/includes/pre_main_global.conf, is loaded prior to the main httpd.conf with the domain specific rules for the container. My assertion is that .cfm pages are failing to be rewritten due to the mod_jk22.so module having priority in the directive chain. To note, I also have a WordPress blog in the site where the rewrites appear to be working fine. For example the following code to remove the index file works fine for php and fails with cfm ... .htaccess under /blog/ : This works Options -Indexes -Multiviews <IfModule mod_rewrite.c> RewriteEngine On RewriteBase /blog/ RewriteRule ^index\.php$ - [L] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /blog/index.php [L] </IfModule> .htaccess under / : This does not work as expected. Apache serves the page. ASSERT: This would redirect to domain.com/ without index.cfm Options -Indexes -Multiviews <IfModule mod_rewrite.c> RewriteEngine On RewriteBase / RewriteRule ^index\.cfm$ - [L] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /index.cfm [L] </IfModule> .htaccess under / : This works I'm presuming this is working because the redirect is to another .cfm page and a 404 handler in Application.cfc ... Options -Indexes -Multiviews <IfModule mod_rewrite.c> RewriteEngine On RewriteBase / RewriteRule ^.*\.cfm$ - [L] RewriteCond %{REQUEST_FILENAME} !-d RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{ENV:REDIRECT_STATUS} =404 RewriteRule . /404.cfm$ [L] </IfModule> I've attempted numerous different methods to rewrite .cfm urls ... Adding [PT], [L], [R], [NS], Moving the script to Directory blocks under httpd.conf --- all with the same results ... either the rewrite doesn't work or Apache crashes in an endless loop ... Any help would be greatly appreciated. Below is a single-visit rewrite log snippet for a request to /index.cfm ... the pass-through is taking effect before the rewrite ... cat rewrite_dump_mod | grep index.cfm [perdir /home/foo/public_html/] strip per-dir prefix: /home/foo/public_html/index.cfm -> index.cfm [perdir /home/foo/public_html/] applying pattern '^.*\.cfm$' to uri 'index.cfm' [perdir /home/foo/public_html/] pass through /home/foo/public_html/index.cfm [perdir /home/foo/public_html/] strip per-dir prefix: /home/foo/public_html/index.cfm -> index.cfm [perdir /home/foo/public_html/] applying pattern '^.*\.cfm$' to uri 'index.cfm' [perdir /home/foo/public_html/] pass through /home/foo/public_html/index.cfm * UPDATE * I've managed to figure this out ... it took a while ... Options -Indexes -Multiviews +FollowSymLinks <IfModule mod_rewrite.c> RewriteEngine On RewriteBase / RewriteCond %{HTTP_HOST} !^www\. RewriteRule ^(.*)$ http://www.%{HTTP_HOST}/$1 [R=301,L] RewriteCond %{THE_REQUEST} ^.*/index\.cfm RewriteRule ^(.*)index.cfm http://%{HTTP_HOST}/$1 [R=301,L] </IfModule>

    Read the article

  • Getting Started with Media Browser for Windows Media Center

    - by DigitalGeekery
    If you are a Windows Media Center user, you’ll really want to check out Media Browser. The Media Browser plug-in for Windows Media Center takes your digital media files and displays them in a visually appealing, user friendly interface, complete with images and metadata. Requirements Windows 7 or Vista Microsoft .Net 3.5 Framework  Preparing your Media Files For Media Browser to be able to automatically download images and metadata for your media libraries, your files will have to be correctly named. For example, if you have an mp4 file of the movie Batman Begins, it needs to be named Batman Begins.mp4. It cannot be Batmanbegins.mp4 or Batman-begins.mp4. Otherwise, it’s unlikely that Media Browser will display images and metadata. If you find some of your files aren’t pulling cover art or metadata, double-check the official title of the media on a site like IMBD.com. TV Show files TV show files are handled a bit differently. Every TV series in your collection must have a main folder with the show’s name and individual subfolders for each season. Here is an example of folder structure and supported naming conventions. TV Shows\South Park\Season 1\s01e01 – episode 1.mp4 TV Shows\South Park\Season 1\South Park 1×01 – episode 1.mp4 TV Shows\South Park\Season 1\101 – episode 1.mp4  Note: You need to always have a Season 1 folder even if the show only has only one season. If you have several seasons of a particular show, but don’t happen to have Season 1, simply create a blank season 1 folder. Without a season 1 folder, other seasons will not display properly. Installation and Configuration Download and run the latest Media Browser .msi file by taking the defaults. (Download link below) When you reach the final window, leave the “Configure initial settings” box checked, and click “Finish.” You may get a pop up window informing you that folder permissions are not set correctly for Media Browser. Click “Yes.” Adding Your Media The Browser Configuration Tool should have opened automatically. If not, you can open it by going to Start > All Programs > Media Browser > Media Browser Configuration Wizard. To begin adding media files, click “Add.” Browse for a folder that contains media files and click “OK.” Here we are adding a folder with a group of movie files. You can add multiple folders to each media library. For example, if you have movie files stored in 4 or 5 different folders, you can add them all under a single library in Media Browser.  To add additional folders, click the “Add” button on the right side under your currently added folder. The “Add” button to the left will add an additional Media Library, such as one for TV Shows. When you are finished, close out of the Media Browser Configuration Tool. Open Windows Media Center. You will see Media Browser tile on the main interface. Click to open it. When you initially open Media Browser, you will be prompted to run the initial configuration. Click “OK.” You will see a few general configuration options. The important option is the Metadata. Leave this option checked (it is by default) if you wish to pull images & other metadata for your media. When finished, click “Continue,” and then “OK” to restart Media Browser. When you re-enter Media Browser you’ll see your Media Categories listed below, and recently added files in the main display. Click on a Media Library to view the files.   Click “View” at the top to check out some of the different display options to choose from. Below you see can “Detail.” This presents your videos in a list to the left. When you hover over a title, the synopsis and cover art is displayed to the right. “Cover Flow” displays your titles in a right to left format with mirror cover art. “Thumb Strip” displays your titles in a strip along the bottom with a synopsis, image, and movie data above. Configurations Settings and options can be changed through the Media Browser Configuration Tool, or directly in Media Browser by clicking on the “Wrench” at the bottom right of the main Media Browser page. Certain settings may only be available in one location or the other. Some will be available in both places.   Plug-ins and Themes Media Browser features a variety of Plug-ins and Themes that can add optional customization and slick visual appeal. To install plug-ins or themes, open the Media Browser Configuration Tool. Click on the “plug-ins” tab, and then the “More Plug-ins…” button. Note: Clicking on “Advanced” at the top will reveal several additional configuration tabs. Browse the list of plug-ins on the left. When you find want you like, select it and then click “Install.” When the install is complete, you’ll see them listed under “Installed Plug-ins.” To activate any installed theme, click on the “Display” tab. Select it from the Visual Theme drop down list. Close out of the Media Browser Configuration Tool when finished. Some themes, such as the “Diamond” theme shown below, include optional views and settings which can be accessed through a configuration button at the top of the screen. Clicking on the movie gives you additional images and information such as a synopsis, runtime, IMDB rating…   … and even actors and character names.   All that’s left is to hit “Play” when you’re ready to watch.   Conclusion Media Browser is a fantastic plug-in that brings an entirely different level of media management and aesthetics to Windows Media Center. There are numerous additional customizations and configurations we have not covered here such as adding film trailers, music support, and integrating Recorded TV. Media Browser will run on both Windows 7 and Vista. Extenders are also supported but may require additional configuration. Download Media Browser Similar Articles Productive Geek Tips Using Netflix Watchnow in Windows Vista Media Center (Gmedia)Schedule Updates for Windows Media CenterIntegrate Hulu Desktop and Windows Media Center in Windows 7Add Color Coding to Windows 7 Media Center Program GuideIntegrate Boxee with Media Center in Windows 7 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 If it were only this easy SyncToy syncs Files and Folders across Computers on a Network (or partitions on the same drive) Classic Cinema Online offers 100’s of OnDemand Movies OutSync will Sync Photos of your Friends on Facebook and Outlook Windows 7 Easter Theme YoWindoW, a real time weather screensaver

    Read the article

  • OpenGL font rendering

    - by DEElekgolo
    I am trying to make an openGL text rendering class using FreeType. I was originally following this code but it doesn't seem to work out for me. I get nothing reguardless of what parameters I put for Draw(). class Font { public: Font() { if (FT_Init_FreeType(&ftLibrary)) { printf("Could not initialize FreeType library\n"); return; } glGenBuffers(1,&iVerts); } bool Load(std::string sFont, unsigned int Size = 12.0f) { if (FT_New_Face(ftLibrary,sFont.c_str(),0,&ftFace)) { printf("Could not open font: %s\n",sFont.c_str()); return true; } iSize = Size; FT_Set_Pixel_Sizes(ftFace,0,(int)iSize); FT_GlyphSlot gGlyph = ftFace->glyph; //Generating the texture atlas. //Rather than some amazing rectangular packing method, I'm just going //to have one long strip of letters with the height being that of the font size. int width = 0; int height = 0; for (int i = 32; i < 128; i++) { if (FT_Load_Char(ftFace,i,FT_LOAD_RENDER)) { printf("Error rendering letter %c for font %s.\n",i,sFont.c_str()); } width += gGlyph->bitmap.width; height += std::max(height,gGlyph->bitmap.rows); } //Generate the openGL texture glActiveTexture(GL_TEXTURE0); //if I texture exists then delete it. iTexture ? glDeleteBuffers(1,&iTexture):0; glGenTextures(1,&iTexture); glBindTexture(GL_TEXTURE_2D,iTexture); glPixelStorei(GL_UNPACK_ALIGNMENT,1); glTexImage2D(GL_TEXTURE_2D,0,GL_ALPHA,width,height,0,GL_ALPHA,GL_UNSIGNED_BYTE,0); glTexParameteri(GL_TEXTURE_2D, GL_TEXTURE_WRAP_S, GL_CLAMP_TO_EDGE); glTexParameteri(GL_TEXTURE_2D, GL_TEXTURE_WRAP_T, GL_CLAMP_TO_EDGE); glTexParameteri(GL_TEXTURE_2D, GL_TEXTURE_MIN_FILTER, GL_LINEAR); glTexParameteri(GL_TEXTURE_2D, GL_TEXTURE_MAG_FILTER, GL_LINEAR); //load the glyphs and set the glyph data int x = 0; for (int i = 32; i < 128; i++) { if (FT_Load_Char(ftFace,i,FT_LOAD_RENDER)) { //if it cant load the character continue; } //load the glyph map into the texture glTexSubImage2D(GL_TEXTURE_2D,0,x,0, gGlyph->bitmap.width, gGlyph->bitmap.rows, GL_ALPHA, GL_UNSIGNED_BYTE, gGlyph->bitmap.buffer); //move the "pen" down the strip x += gGlyph->bitmap.width; chars[i].ax = (float)(gGlyph->advance.x >> 6); chars[i].ay = (float)(gGlyph->advance.y >> 6); chars[i].bw = (float)gGlyph->bitmap.width; chars[i].bh = (float)gGlyph->bitmap.rows; chars[i].bl = (float)gGlyph->bitmap_left; chars[i].bt = (float)gGlyph->bitmap_top; chars[i].tx = (float)x/width; } printf("Loaded font: %s\n",sFont.c_str()); return true; } void Draw(std::string sString,Vector2f vPos = Vector2f(0,0),Vector2f vScale = Vector2f(1,1)) { struct pPoint { pPoint() { x = y = s = t = 0; } pPoint(float a,float b,float c,float d) { x = a; y = b; s = c; t = d; } float x,y; float s,t; }; pPoint* cCoordinates = new pPoint[6*sString.length()]; int n = 0; for (const char *p = sString.c_str(); *p; p++) { float x2 = vPos.x() + chars[*p].bl * vScale.x(); float y2 = -vPos.y() - chars[*p].bt * vScale.y(); float w = chars[*p].bw * vScale.x(); float h = chars[*p].bh * vScale.y(); float x = vPos.x() + chars[*p].ax * vScale.x(); float y = vPos.y() + chars[*p].ay * vScale.y(); //skip characters with no pixels //still advances though if (!w || !h) { continue; } //triangle one cCoordinates[n++] = pPoint( x2 , -y2 , chars[*p].tx , 0); cCoordinates[n++] = pPoint( x2+w , -y2 , chars[*p].tx + chars[*p].bw / w , 0); cCoordinates[n++] = pPoint( x2 , -y2-h , chars[*p].tx , chars[*p].bh / h); cCoordinates[n++] = pPoint( x2+w , -y2 , chars[*p].tx + chars[*p].bw / w , 0); cCoordinates[n++] = pPoint( x2 , -y2-h , chars[*p].tx , chars[*p].bh / h); cCoordinates[n++] = pPoint( x2+w , -y2-h , chars[*p].tx + chars[*p].bw / w , chars[*p].bh / h); } glBindBuffer(GL_ARRAY_BUFFER,iVerts); glBindBuffer(GL_TEXTURE_2D,iTexture); //Vertices glEnableClientState(GL_VERTEX_ARRAY); glVertexPointer(2,GL_FLOAT,sizeof(pPoint),&cCoordinates[0].x); //TexCoord 0 glClientActiveTexture(GL_TEXTURE0); glEnableClientState(GL_TEXTURE_COORD_ARRAY); glTexCoordPointer(2,GL_FLOAT,sizeof(pPoint),&cCoordinates[0].s); glCullFace(GL_NONE); glBufferData(GL_ARRAY_BUFFER,6*sString.length(),cCoordinates,GL_DYNAMIC_DRAW); glDrawArrays(GL_TRIANGLES,0,n); glCullFace(GL_BACK); glBindBuffer(GL_ARRAY_BUFFER,0); glBindBuffer(GL_TEXTURE_2D,0); glDisableClientState(GL_VERTEX_ARRAY); glDisableClientState(GL_TEXTURE_COORD_ARRAY); } ~Font() { glDeleteBuffers(1,&iVerts); glDeleteBuffers(1,&iTexture); } private: unsigned int iSize; //openGL texture atlas unsigned int iTexture; //openGL geometry buffer; unsigned int iVerts; FT_Library ftLibrary; FT_Face ftFace; struct Character { float ax,ay;//Advance float bw,bh;//bitmap size float bl,bt;//bitmap left and top float tx; } chars[128]; };

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • PERC H710 mini raid controller advanced settings (BIOS)

    - by gregg
    I upgraded from a PERC h310 to an H710 controller on my Dell R620 but didnt get any increase in performance. This is a ESXi host with a 5 disk RAID 5. I noticed when going to the RAID BIOS that the advanced settings section was not activated/checked off. In that section is the strip element size: 64kb (default) read policy: no read ahead and the write policy: write-through. Will checking that section do any harm to the existing raid array or will it simply enable those policies and hopefully boost performance? Or, lastly, is it already using those policies and the checkmark is simply to activate them for changes

    Read the article

< Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >