Search Results

Search found 13467 results on 539 pages for 'port mapping'.

Page 151/539 | < Previous Page | 147 148 149 150 151 152 153 154 155 156 157 158  | Next Page >

  • How can I map a spring controller to a url with .jsp extension?

    - by Matteo Caprari
    Hi. We are in the process of migrating a jsp-only application to Spring-MVC. For various reasons we can't change the extension of the current pages. (calls to login.jsp need to handled by a spring controller that will use a jsp file as view). We are doing this iteratively, so some pages need to stay jsp files (calls to welcome.jsp won't be handled by a controller). To do that I mapped both the DispatcherDervlet and the HandlerMapping to *.jsp, and configured the JstlView in the standard way. Unfortunately, if I browse to //login.jsp I get an error saying <No mapping found for HTTP request with URI [/<context>/WEB-INF/jsp/login.jsp] in DispatcherServlet with name 'spring'> It all works if I change .jsp to any other extension in DispatcherServlet and HandlerMapping. web.xml: <servlet> <servlet-name>spring</servlet-name> <servlet-class>org.springframework.web.servlet.DispatcherServlet</servlet-class> <load-on-startup>1</load-on-startup> </servlet> <servlet-mapping> <servlet-name>spring</servlet-name> <url-pattern>*.jsp</url-pattern> </servlet-mapping> spring-servlet.xml: <!-- View resolver --> <bean id="viewResolver" class="org.springframework.web.servlet.view.UrlBasedViewResolver"> <property name="viewClass" value="org.springframework.web.servlet.view.JstlView"/> <property name="prefix" value="/WEB-INF/jsp/"/> <property name="suffix" value=".jsp"/> </bean> <!-- URL Mapping --> <bean id="publicUrlMapping" class="org.springframework.web.servlet.handler.SimpleUrlHandlerMapping"> <property name="urlMap"> <map> <entry key="/login.jsp" value-ref="loginController"/> </map> </property> </bean> Thanks a lot.

    Read the article

  • Data not synchornizing java sockets

    - by Droid_Interceptor
    I am writing a auction server and client and using a class called BidHandler to deal with the bids another class AuctionItem to deal with the items for auction. The main problem I am having is little synchroization problem. Screen output of client server as can see from the image at 1st it takes the new bid and changes the value of the time to it, but when one the user enters 1.0 the item seems to be changed to that. But later on when the bid changes again to 15.0 it seems to stay at that price. Is there any reason for that. I have included my code below. Sorry if didnt explain this well. This is the auction client import java.io.*; import java.net.*; public class AuctionClient { private AuctionGui gui; private Socket socket; private DataInputStream dataIn; private DataOutputStream dataOut; //Auction Client constructor String name used as identifier for each client to allow server to pick the winning bidder public AuctionClient(String name,String server, int port) { gui = new AuctionGui("Bidomatic 5000"); gui.input.addKeyListener (new EnterListener(this,gui)); gui.addWindowListener(new ExitListener(this)); try { socket = new Socket(server, port); dataIn = new DataInputStream(socket.getInputStream()); dataOut = new DataOutputStream(socket.getOutputStream()); dataOut.writeUTF(name); while (true) { gui.output.append("\n"+dataIn.readUTF()); } } catch (Exception e) { e.printStackTrace(); } } public void sentBid(String bid) { try { dataOut.writeUTF(bid); } catch(IOException e) { e.printStackTrace(); } } public void disconnect() { try { socket.close(); } catch(IOException e) { e.printStackTrace(); } } public static void main (String args[]) throws IOException { if(args.length!=3) { throw new RuntimeException ("Syntax: java AuctionClient <name> <serverhost> <port>"); } int port = Integer.parseInt(args[2]); AuctionClient a = new AuctionClient(args[0],args[1],port); } } The Auction Server import java.io.*; import java.net.*; import java.util.*; public class AuctionServer { public AuctionServer(int port) throws IOException { ServerSocket server = new ServerSocket(port); while(true) { Socket client = server.accept(); DataInputStream in = new DataInputStream(client.getInputStream()); String name = in.readUTF(); System.out.println("New client "+name+" from " +client.getInetAddress()); BidHandler b = new BidHandler (name, client); b.start(); } } public static void main(String args[]) throws IOException { if(args.length != 1) throw new RuntimeException("Syntax: java AuctionServer <port>"); new AuctionServer(Integer.parseInt(args[0])); } } The BidHandler import java.net.*; import java.io.*; import java.util.*; import java.lang.Float; public class BidHandler extends Thread { Socket socket; DataInputStream in; DataOutputStream out; String name; float currentBid = 0.0f; AuctionItem paper = new AuctionItem(" News Paper ", " Free newspaper from 1990 ", 1.0f, false); protected static Vector handlers = new Vector(); public BidHandler(String name, Socket socket) throws IOException { this.name = name; this.socket = socket; in = new DataInputStream (new BufferedInputStream (socket.getInputStream())); out = new DataOutputStream(new BufferedOutputStream(socket.getOutputStream())); } public synchronized void run() { try { broadcast("New bidder has entered the room"); handlers.addElement(this); while(true) { broadcast(paper.getName() + paper.getDescription()+" for sale at: " +paper.getPrice()); while(paper.getStatus() == false) { String message = in.readUTF(); currentBid = Float.parseFloat(message); broadcast("Bidder entered " +currentBid); if(currentBid > paper.getPrice()) { paper.setPrice(currentBid); broadcast("New Higgest Bid is "+paper.getPrice()); } else if(currentBid < paper.getPrice()) { broadcast("Higgest Bid is "+paper.getPrice()); } else if(currentBid == paper.getPrice()) { broadcast("Higgest Bid is "+paper.getPrice()); } } } } catch(IOException ex) { System.out.println("-- Connection to user lost."); } finally { handlers.removeElement(this); broadcast(name+" left"); try { socket.close(); } catch(IOException ex) { System.out.println("-- Socket to user already closed ?"); } } } protected static void broadcast (String message) { synchronized(handlers) { Enumeration e = handlers.elements(); while(e.hasMoreElements()) { BidHandler handler = (BidHandler) e.nextElement(); try { handler.out.writeUTF(message); handler.out.flush(); } catch(IOException ex) { handler = null; } } } } } The AuctionItem Class class AuctionItem { String itemName; String itemDescription; float itemPrice; boolean itemStatus; //Create a new auction item with name, description, price and status public AuctionItem(String name, String description, float price, boolean status) { itemName = name; itemDescription = description; itemPrice = price; itemStatus = status; } //return the price of the item. public synchronized float getPrice() { return itemPrice; } //Set the price of the item. public synchronized void setPrice(float newPrice) { itemPrice = newPrice; } //Get the status of the item public synchronized boolean getStatus() { return itemStatus; } //Set the status of the item public synchronized void setStatus(boolean newStatus) { itemStatus = newStatus; } //Get the name of the item public String getName() { return itemName; } //Get the description of the item public String getDescription() { return itemDescription; } } There is also simple GUI to go with this that seems to be working fine. If anyone wants it will include the GUI code.

    Read the article

  • SEC_TO_TIME() convert to java.sql.Time error

    - by chun
    hi I have a aggregate column present the microsecond, a report(with jasper) have to show HH:mm:ss of this indicator What I did is using SEC_TO_TIME(sum(col)/1000) , but when mapping to java.sql.Time, i doesn't work when the value of hour in result pass over 24(ex:36:33:33) Then I think another way, not using sec_to_time, just mapping the microsecond as Bigdecimal, but dunno what java class shoud i use to format date as the default format of hh:mm:ss is limit to 24...?

    Read the article

  • using external maps with bing map

    - by user230408
    can i use bing map platform with an external mapping source ? for example, i want to use bing map siverlight client with my own map files instead of the provided maps. (some areas coverage is insufficiant with bings provided mapping) Thanks.

    Read the article

  • Hibernate3: Self-Referencing Objects

    - by monojohnny
    Need some help on understanding how to do this; I'm going to be running recursive 'find' on a file system and I want to keep the information in a single DB table - with a self-referencing hierarchial structure: This is my DB Table structure I want to populate. DirObject Table: id int NOT NULL, name varchar(255) NOT NULL, parentid int NOT NULL); Here is the proposed Java Class I want to map (Fields only shown): public DirObject { int id; String name; DirObject parent; ... For the 'root' directory was going to use parentid=0; real ids will start at 1, and ideally I want hibernate to autogenerate the ids. Can somebody provide a suggested mapping file for this please; as a secondary question I thought about doing the Java Class like this instead: public DirObject { int id; String name; List<DirObject> subdirs; Could I use the same data model for either of these two methods ? (With a different mapping file of course). --- UPDATE: so I tried the mapping file suggested below (thanks!), repeated here for reference: <hibernate-mapping> <class name="my.proj.DirObject" table="category"> ... <set name="subDirs" lazy="true" inverse="true"> <key column="parentId"/> <one-to-many class="my.proj.DirObject"/> </set> <many-to-one name="parent" class="my.proj.DirObject" column="parentId" cascade="all" /> </class> ...and altered my Java class to have BOTH 'parentid' and 'getSubDirs' [returning a 'HashSet']. This appears to work - thanks, but this is the test code I used to drive this - I think I'm not doing something right here, because I thought Hibernate would take care of saving the subordinate objects in the Set without me having to do this explicitly ? DirObject dirobject=new DirObject(); dirobject.setName("/files"); dirobject.setParent(dirobject); DirObject d1, d2; d1=new DirObject(); d1.setName("subdir1"); d1.setParent(dirobject); d2=new DirObject(); d2.setName("subdir2"); d2.setParent(dirobject); HashSet<DirObject> subdirs=new HashSet<DirObject>(); subdirs.add(d1); subdirs.add(d2); dirobject.setSubdirs(subdirs); session.save(dirobject); session.save(d1); session.save(d2);

    Read the article

  • How to configure path to mappings to be used in hibernate.cfg.xml with maven (hbm2cfgxml)

    - by user342358
    Hi, can any one tell me how to force maven to precede mapping .hbm.xml files in the automatically generated hibernate.cfg.xml file with package path? My general idea is, I'd like to use hibernate-tools via maven to generate the persistence layer for my application. So, I need the hibernate.cfg.xml, then all my_table_names.hbm.xml and at the end the POJO's generated. Yet, the hbm2java goal won't work as I put *.hbm.xml files into the src/main/resources/package/path/ folder but hbm2cfgxml specifies the mapping files only by table name, i.e.: <mapping resource="MyTableName.hbm.xml" /> So the big question is: how can I configure hbm2cfgxml so that hibernate.cfg.xml looks like below: <mapping resource="package/path/MyTableName.hbm.xml" /> My pom.xml looks like this at the moment: <plugin> <groupId>org.codehaus.mojo</groupId> <artifactId>hibernate3-maven-plugin</artifactId> <version>2.2</version> <executions> <execution> <id>hbm2cfgxml</id> <phase>generate-sources</phase> <goals> <goal>hbm2cfgxml</goal> </goals> <inherited>false</inherited> <configuration> <components> <component> <name>hbm2cfgxml</name> <implemetation>jdbcconfiguration</implementation> <outputDirectory>src/main/resources/</outputDirectory> </component> </components> <componentProperties> <packagename>package.path</packageName> <configurationFile>src/main/resources/hibernate.cfg.xml</configurationFile> </componentProperties> </configuration> </execution> </executions> </plugin> And then the second question: is there a way to tell maven to copy resources to the target folder before executing hbm2java? At the moment I'm using mvn clean resources:resources generate-sources for that, but there must be a better way. Thanks for any help.

    Read the article

  • how to upload a audio file using REST webservice in Google App Engine for Java

    - by sathya
    Am using google app engine with eclipse IDE and trying to upload a audio file. I used the File Upload in Google App Engine For Java and can able to upload the file successfully. Now am planning to use REST web service for it. I had analyzed in developers.google but i failed. Can anyone suggest me how to implement REST Web services in google app engine using Eclipse. The code google provided is shown below, // file Upload.java public class Upload extends HttpServlet { private BlobstoreService blobstoreService = BlobstoreServiceFactory.getBlobstoreService(); public void doPost(HttpServletRequest req, HttpServletResponse res) throws ServletException, IOException { Map<String, BlobKey> blobs = blobstoreService.getUploadedBlobs(req); BlobKey blobKey = blobs.get("myFile"); if (blobKey == null) { res.sendRedirect("/"); } else { res.sendRedirect("/serve?blob-key=" + blobKey.getKeyString()); }}} // file Serve.java public class Serve extends HttpServlet { private BlobstoreService blobstoreService = BlobstoreServiceFactory.getBlobstoreService(); public void doGet(HttpServletRequest req, HttpServletResponse res) throws IOException { BlobKey blobKey = new BlobKey(req.getParameter("blob-key")); blobstoreService.serve(blobKey, res); }} // file index.jsp <%@ page import="com.google.appengine.api.blobstore.BlobstoreServiceFactory" %> <%@ page import="com.google.appengine.api.blobstore.BlobstoreService" %> <% BlobstoreService blobstoreService = BlobstoreServiceFactory.getBlobstoreService(); %> <form action="<%= blobstoreService.createUploadUrl("/upload") %>" method="post" enctype="multipart/form-data"> <input type="file" name="myFile"> <input type="submit" value="Submit"> </form> // web.xml <servlet> <servlet-name>Upload</servlet-name> <servlet-class>Upload</servlet-class> </servlet> <servlet> <servlet-name>Serve</servlet-name> <servlet-class>Serve</servlet-class> </servlet> <servlet-mapping> <servlet-name>Upload</servlet-name> <url-pattern>/upload</url-pattern> </servlet-mapping> <servlet-mapping> <servlet-name>Serve</servlet-name> <url-pattern>/serve</url-pattern> </servlet-mapping> Now how to provide a rest web service for the above code. Kindly suggest me an idea.

    Read the article

  • How to get Django url correctly?

    - by Satoru.Logic
    Hi, all. I have set up a url mapping that goes like this: (r'enroll/$', 'enroll') In my development environment this mapping is used when I visit '/enroll/'. But in the production environment, the Django application is under '/activity/' and '/activity/enroll/' should be used. Please tell me how do I get the correct url in both cases. Thanks in advance.

    Read the article

  • How to use LINQ for CRUD with a simple SQL table?

    - by Rob Ferno
    Every LINQ blog I found there seemed around 2 years old, I understand the syntax but need more direction on creating the SQL mapping and context classes. I just need to use LINQ for 2 SQL tables I have, nothing complicated. Do folks write the SQL mapping classes by hand for such cases or is there a decent tool for this? Can someone point me in the right direction?

    Read the article

  • Hibernate Queries

    - by Schildmeijer
    Using Named Queries (located in your hibernate mapping xml file) is a nice way to separate your queries from your buisness logic. But what are the alternatives if your are using Hibernate Annotations for mapping?

    Read the article

  • How to match 2 columns in excel?

    - by abhijithln
    Hi, I have an excel sheet, sheet1 which has 2 cols, A and B. Col A has some values and has corresponding mapping in col B(not all values in A have a mapping in B, some are empty). The sorting is done from Z-A and w.r.to Col A. I have another excel sheet, sheet2 which has similar Col A and Col B. Now, i want to find out whether any match is there between Col A of sheet1 and Col A of sheet2. If matches are found, those values should be copied onto a new column.

    Read the article

  • from Hibernate hbm to JPA annotations, a challenging one

    - by nodje
    Hi, I've been struggling with this one for quite some time already. It appears a lot less simple than I thought it'd be: This is included in the "COTISATION" table mapping an uses SynchroDataType, extending Hibernate UserType. This works really great, and I can't find a way to translate it to proper JPA, while keeping the convenience of it. Does someone has a solution for that kind of one-to-one mapping? cheers

    Read the article

  • openvpn: after changing to server mode, client does not create TUN device

    - by lurscher
    i had a previously working configuration with the config files used in a previous question However, i've changed this now to the following configuration using server mode, everything on the logs seem fine, however the client doesn't create any tun interface, so i don't have anything to connect to, presumably, i need to add or push some route commands, but i don't have any idea at this point what i need to do. I am posting all my relevant configuration files server.conf: dev tun server 10.8.117.0 255.255.255.0 ifconfig-pool-persist ipp.txt tls-server dh /home/lurscher/keys/dh1024.pem ca /home/lurscher/keys/ca.crt cert /home/lurscher/keys/vpnCh8TestServer.crt key /home/lurscher/keys/vpnCh8TestServer.key status openvpn-status.log log openvpn.log comp-lzo verb 3 and client.conf: dev tun remote my.server.com tls-client ca /home/chuckq/keys/ca.crt cert /home/chuckq/keys/vpnCh8TestClient.crt key /home/chuckq/keys/vpnCh8TestClient.key ns-cert-type server ; port 1194 ; user nobody ; group nogroup status openvpn-status.log log openvpn.log comp-lzo verb 3 the server ifconfig shows a tun device: tun0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 inet addr:10.8.117.1 P-t-P:10.8.117.2 Mask:255.255.255.255 UP POINTOPOINT RUNNING NOARP MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) However the client ifconfig does not show any tun interface! $ ifconfig tun0 tun0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 POINTOPOINT NOARP MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) the client log says: Tue May 17 23:27:09 2011 OpenVPN 2.1.0 i686-pc-linux-gnu [SSL] [LZO2] [EPOLL] [PKCS11] [MH] [PF_INET6] [eurephia] built on Jul 12 2010 Tue May 17 23:27:09 2011 IMPORTANT: OpenVPN's default port number is now 1194, based on an official port number assignment by IANA. OpenVPN 2.0-beta16 and earlier used 5000 as the default port. Tue May 17 23:27:09 2011 NOTE: the current --script-security setting may allow this configuration to call user-defined scripts Tue May 17 23:27:09 2011 /usr/bin/openssl-vulnkey -q -b 1024 -m <modulus omitted> Tue May 17 23:27:09 2011 LZO compression initialized Tue May 17 23:27:09 2011 Control Channel MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Tue May 17 23:27:09 2011 TUN/TAP device tun0 opened Tue May 17 23:27:09 2011 TUN/TAP TX queue length set to 100 Tue May 17 23:27:09 2011 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Tue May 17 23:27:09 2011 Local Options hash (VER=V4): '41690919' Tue May 17 23:27:09 2011 Expected Remote Options hash (VER=V4): '530fdded' Tue May 17 23:27:09 2011 Socket Buffers: R=[114688->131072] S=[114688->131072] Tue May 17 23:27:09 2011 UDPv4 link local (bound): [undef] Tue May 17 23:27:09 2011 UDPv4 link remote: [AF_INET]192.168.0.101:1194 Tue May 17 23:27:09 2011 TLS: Initial packet from [AF_INET]192.168.0.101:1194, sid=8e8bdc33 f4275407 Tue May 17 23:27:09 2011 VERIFY OK: depth=1, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=Ubuntu_CA/name=lurscher/[email protected] Tue May 17 23:27:09 2011 VERIFY OK: nsCertType=SERVER Tue May 17 23:27:09 2011 VERIFY OK: depth=0, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=vpnCh8TestServer/name=lurscher/[email protected] Tue May 17 23:27:09 2011 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:09 2011 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:09 2011 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:09 2011 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:09 2011 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Tue May 17 23:27:09 2011 [vpnCh8TestServer] Peer Connection Initiated with [AF_INET]192.168.0.101:1194 Tue May 17 23:27:10 2011 Initialization Sequence Completed the client status log: OpenVPN STATISTICS Updated,Tue May 17 23:30:09 2011 TUN/TAP read bytes,0 TUN/TAP write bytes,0 TCP/UDP read bytes,5604 TCP/UDP write bytes,4244 Auth read bytes,0 pre-compress bytes,0 post-compress bytes,0 pre-decompress bytes,0 post-decompress bytes,0 END and the server log says: Tue May 17 23:18:25 2011 OpenVPN 2.1.0 x86_64-pc-linux-gnu [SSL] [LZO2] [EPOLL] [PKCS11] [MH] [PF_INET6] [eurephia] built on Jul 12 2010 Tue May 17 23:18:25 2011 IMPORTANT: OpenVPN's default port number is now 1194, based on an official port number assignment by IANA. OpenVPN 2.0-beta16 and earlier used 5000 as the default port. Tue May 17 23:18:25 2011 WARNING: --keepalive option is missing from server config Tue May 17 23:18:25 2011 NOTE: your local LAN uses the extremely common subnet address 192.168.0.x or 192.168.1.x. Be aware that this might create routing conflicts if you connect to the VPN server from public locations such as internet cafes that use the same subnet. Tue May 17 23:18:25 2011 NOTE: the current --script-security setting may allow this configuration to call user-defined scripts Tue May 17 23:18:25 2011 Diffie-Hellman initialized with 1024 bit key Tue May 17 23:18:25 2011 /usr/bin/openssl-vulnkey -q -b 1024 -m <modulus omitted> Tue May 17 23:18:25 2011 TLS-Auth MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Tue May 17 23:18:25 2011 ROUTE default_gateway=192.168.0.1 Tue May 17 23:18:25 2011 TUN/TAP device tun0 opened Tue May 17 23:18:25 2011 TUN/TAP TX queue length set to 100 Tue May 17 23:18:25 2011 /sbin/ifconfig tun0 10.8.117.1 pointopoint 10.8.117.2 mtu 1500 Tue May 17 23:18:25 2011 /sbin/route add -net 10.8.117.0 netmask 255.255.255.0 gw 10.8.117.2 Tue May 17 23:18:25 2011 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Tue May 17 23:18:25 2011 Socket Buffers: R=[126976->131072] S=[126976->131072] Tue May 17 23:18:25 2011 UDPv4 link local (bound): [undef] Tue May 17 23:18:25 2011 UDPv4 link remote: [undef] Tue May 17 23:18:25 2011 MULTI: multi_init called, r=256 v=256 Tue May 17 23:18:25 2011 IFCONFIG POOL: base=10.8.117.4 size=62 Tue May 17 23:18:25 2011 IFCONFIG POOL LIST Tue May 17 23:18:25 2011 vpnCh8TestClient,10.8.117.4 Tue May 17 23:18:25 2011 Initialization Sequence Completed Tue May 17 23:27:22 2011 MULTI: multi_create_instance called Tue May 17 23:27:22 2011 192.168.0.104:1194 Re-using SSL/TLS context Tue May 17 23:27:22 2011 192.168.0.104:1194 LZO compression initialized Tue May 17 23:27:22 2011 192.168.0.104:1194 Control Channel MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Tue May 17 23:27:22 2011 192.168.0.104:1194 Local Options hash (VER=V4): '530fdded' Tue May 17 23:27:22 2011 192.168.0.104:1194 Expected Remote Options hash (VER=V4): '41690919' Tue May 17 23:27:22 2011 192.168.0.104:1194 TLS: Initial packet from [AF_INET]192.168.0.104:1194, sid=8972b565 79323f68 Tue May 17 23:27:22 2011 192.168.0.104:1194 VERIFY OK: depth=1, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=Ubuntu_CA/name=lurscher/[email protected] Tue May 17 23:27:22 2011 192.168.0.104:1194 VERIFY OK: depth=0, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=Ubuntu_CA/name=lurscher/[email protected] Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:22 2011 192.168.0.104:1194 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Tue May 17 23:27:22 2011 192.168.0.104:1194 [vpnCh8TestClient] Peer Connection Initiated with [AF_INET]192.168.0.104:1194 Tue May 17 23:27:22 2011 vpnCh8TestClient/192.168.0.104:1194 MULTI: Learn: 10.8.117.6 -> vpnCh8TestClient/192.168.0.104:1194 Tue May 17 23:27:22 2011 vpnCh8TestClient/192.168.0.104:1194 MULTI: primary virtual IP for vpnCh8TestClient/192.168.0.104:1194: 10.8.117.6 finally, the server status log: OpenVPN CLIENT LIST Updated,Tue May 17 23:36:25 2011 Common Name,Real Address,Bytes Received,Bytes Sent,Connected Since vpnCh8TestClient,192.168.0.104:1194,4244,5604,Tue May 17 23:27:22 2011 ROUTING TABLE Virtual Address,Common Name,Real Address,Last Ref 10.8.117.6,vpnCh8TestClient,192.168.0.104:1194,Tue May 17 23:27:22 2011 GLOBAL STATS Max bcast/mcast queue length,0 END

    Read the article

  • HP to Cisco spanning tree root flapping

    - by Tim Brigham
    Per a recent question I recently configured both my HP (2x 2900) and Cisco (1x 3750) hardware to use MSTP for interoperability. I thought this was functional until I applied the change to the third device (HP switch 1 below) at which time the spanning tree root started flapping causing performance issues (5% packet loss) between my two HP switches. I'm not sure why. HP Switch 1 A4 connected to Cisco 1/0/1. HP Switch 2 B2 connected to Cisco 2/0/1. HP Switch 1 A2 connected to HP Switch 2 A1. I'd prefer the Cisco stack to act as the root. EDIT: There is one specific line - 'spanning-tree 1 path-cost 500000' in the HP switch 2 that I didn't add and was preexisting. I'm not sure if it could have the kind of impact that I'm describing. I'm more a security and monitoring guy then networking. EDIT 2: I'm starting to believe the problem lies in the fact that the value for my MST 0 instance on the Cisco is still at the default 32768. I worked up a diagram: This is based on every show command I could find for STP. I'll make this change after hours and see if it helps. Cisco 3750 Config: version 12.2 spanning-tree mode mst spanning-tree extend system-id spanning-tree mst configuration name mstp revision 1 instance 1 vlan 1, 40, 70, 100, 250 spanning-tree mst 1 priority 0 vlan internal allocation policy ascending interface TenGigabitEthernet1/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface TenGigabitEthernet2/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface Vlan1 no ip address ! interface Vlan100 ip address 192.168.100.253 255.255.255.0 ! Cisco 3750 show spanning tree: show spanning-tree MST0 Spanning tree enabled protocol mstp Root ID Priority 32768 Address 0004.ea84.5f80 Cost 200000 Port 53 (TenGigabitEthernet1/1/1) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32768 (priority 32768 sys-id-ext 0) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Root FWD 2000 128.53 P2p MST1 Spanning tree enabled protocol mstp Root ID Priority 1 Address a44c.11a6.7c80 This bridge is the root Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 1 (priority 0 sys-id-ext 1) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Desg FWD 2000 128.53 P2p Cisco 3750 show logging: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up HP Switch 1: ; J9049A Configuration Editor; Created on release #T.13.71 vlan 1 name "DEFAULT_VLAN" untagged 1-8,10,13-16,18-23,A1-A4 ip address 100.100.100.17 255.255.255.0 no untagged 9,11-12,17,24 exit vlan 100 name "192.168.100" untagged 9,11-12,17,24 tagged 1-8,10,13-16,18-23,A1-A4 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A4 no ip address exit vlan 40 name "Cafe" tagged 1,4,7,A1-A4 no ip address exit vlan 250 name "Firewall" tagged 1,4,7,A1-A4 no ip address exit vlan 70 name "DMZ" tagged 1,4,7-8,13,A1-A4 no ip address exit spanning-tree spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 password manager password operator HP Switch 1 show spanning tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0021f7-126580 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 363,490 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : 1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 0 IST Remaining Hops : 20 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 | Auto 128 Disabled | A2 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A3 10GbE-CX4 | Auto 128 Disabled | A4 10GbE-SR | Auto 128 Disabled | HP Switch 1 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00842 stp: MSTI 1 starved for an MSTI Msg Rx on port A4 from 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to ... HP Switch 2 Configuration: ; J9146A Configuration Editor; Created on release #W.14.49 vlan 1 name "DEFAULT_VLAN" untagged 1,3-17,21-24,A1-A2,B2 ip address 100.100.100.36 255.255.255.0 no untagged 2,18-20,B1 exit vlan 100 name "192.168.100" untagged 2,18-20 tagged 1,3-17,21-24,A1-A2,B1-B2 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A2,B2 no ip address exit vlan 40 name "Cafe" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 250 name "Firewall" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 70 name "DMZ" tagged 1,13-14,16,A1-A2,B2 no ip address exit logging 192.168.100.18 spanning-tree spanning-tree 1 path-cost 500000 spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 HP Switch 2 Spanning Tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0024a8-cd6000 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 21,793 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : A1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 2000 IST Remaining Hops : 19 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A2 10GbE-CX4 | Auto 128 Disabled | B1 SFP+SR | 2000 128 Forwarding | 0024a8-cd6000 2 Yes No B2 | Auto 128 Disabled | HP Switch 2 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80 00839 stp: IST Root changed from 32768:0021f7-126580 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0004ea-845f80 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00435 ports: port B1 is Blocked by STP 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: IST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80

    Read the article

  • IRQ problem with 2.6.32/2.6.39 kernel on Debian Squeeze x86_64

    - by MasterM
    I recently assembled a new computer so that all hardware is pretty new. Since then I've been experiencing some problem with IRQs when running Debian 6.0. On random occasions, usually after an hour or so of running I hear a beep and this shows up in dmesg: [ 3537.762795] irq 16: nobody cared (try booting with the "irqpoll" option) [ 3537.762797] Pid: 0, comm: swapper Tainted: P W O 2.6.39-2-amd64 #1 [ 3537.762798] Call Trace: [ 3537.762799] <IRQ> [<ffffffff810924d4>] ? __report_bad_irq+0x3a/0xa2 [ 3537.762803] [<ffffffff810926a4>] ? note_interrupt+0x168/0x1da [ 3537.762805] [<ffffffff81090dd4>] ? handle_irq_event_percpu+0x171/0x18f [ 3537.762807] [<ffffffff8100e0e2>] ? read_tsc+0x5/0x16 [ 3537.762809] [<ffffffff8106b8a2>] ? update_ts_time_stats+0x32/0x6b [ 3537.762810] [<ffffffff81090e26>] ? handle_irq_event+0x34/0x52 [ 3537.762812] [<ffffffff81063fb7>] ? sched_clock_idle_wakeup_event+0x12/0x1c [ 3537.762813] [<ffffffff81092df2>] ? handle_fasteoi_irq+0x82/0xa4 [ 3537.762815] [<ffffffff8100aadb>] ? handle_irq+0x1a/0x23 [ 3537.762816] [<ffffffff8100a384>] ? do_IRQ+0x45/0xaa [ 3537.762818] [<ffffffff81332c93>] ? common_interrupt+0x13/0x13 [ 3537.762818] <EOI> [<ffffffff81332c8e>] ? common_interrupt+0xe/0x13 [ 3537.762821] [<ffffffff81026800>] ? native_safe_halt+0x2/0x3 [ 3537.762829] [<ffffffffa016ed58>] ? acpi_idle_do_entry+0x39/0x62 [processor] [ 3537.762831] [<ffffffffa016edde>] ? acpi_idle_enter_c1+0x5d/0xad [processor] [ 3537.762834] [<ffffffff81261033>] ? cpuidle_idle_call+0x11f/0x1cc [ 3537.762835] [<ffffffff81008dd2>] ? cpu_idle+0xab/0xe1 [ 3537.762837] [<ffffffff8169fc60>] ? start_kernel+0x3e0/0x3eb [ 3537.762838] [<ffffffff8169f3c8>] ? x86_64_start_kernel+0x102/0x10f [ 3537.762839] handlers: [ 3537.762840] [<ffffffffa0358d5a>] (rtl8169_interrupt+0x0/0x2d7 [r8169]) [ 3537.762842] [<ffffffffa08ff2ca>] (nv_kern_isr+0x0/0x54 [nvidia]) [ 3537.762902] Disabling IRQ #16 After that Xorg either hogs on CPU or is unstable (up to hanging the system completely). When I restart Xorg everything is fine again and the problem doesn't occur until next reboot. I tried to upgrade the kernel from stock 2.6.32 to 2.6.39 from unstable repository but that didn't help. Booting with irqpoll option only seems to prolong the initial time period after which the problem occurs. I'm using latest NVIDIA drivers and Realtek firmware from firmware-realtek package. I have two GTX 560Ti that run in SLI. Disabling SLI or taking out one card completely doesn't solve the problem either. Output of uname -a is: Linux whitestar 2.6.39-2-amd64 #1 SMP Wed Jun 8 11:01:04 UTC 2011 x86_64 GNU/Linux Output of lspci is: 00:00.0 Host bridge: Intel Corporation Sandy Bridge DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:01.1 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:16.0 Communication controller: Intel Corporation Cougar Point HECI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579V Gigabit Network Connection (rev 05) 00:1a.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation Cougar Point High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 1 (rev b5) 00:1c.1 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 2 (rev b5) 00:1c.2 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 3 (rev b5) 00:1c.4 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 5 (rev b5) 00:1c.6 PCI bridge: Intel Corporation 82801 PCI Bridge (rev b5) 00:1d.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation Cougar Point LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation Cougar Point 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation Cougar Point SMBus Controller (rev 05) 01:00.0 VGA compatible controller: nVidia Corporation Device 1200 (rev a1) 01:00.1 Audio device: nVidia Corporation Device 0e0c (rev a1) 02:00.0 VGA compatible controller: nVidia Corporation Device 1200 (rev a1) 02:00.1 Audio device: nVidia Corporation Device 0e0c (rev a1) 04:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) 06:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) 07:00.0 PCI bridge: Device 1b21:1080 (rev 01) 08:02.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10) 08:03.0 FireWire (IEEE 1394): VIA Technologies, Inc. VT6306/7/8 [Fire II(M)] IEEE 1394 OHCI Controller (rev c0) Contents of /proc/interrupts: CPU0 CPU1 CPU2 CPU3 CPU4 CPU5 CPU6 CPU7 0: 77 0 0 0 0 0 0 0 IO-APIC-edge timer 1: 2 0 0 0 0 0 0 0 IO-APIC-edge i8042 8: 1 0 0 0 0 0 0 0 IO-APIC-edge rtc0 9: 0 0 0 0 0 0 0 0 IO-APIC-fasteoi acpi 12: 4 0 0 0 0 0 0 0 IO-APIC-edge i8042 16: 699083 0 0 0 0 0 0 0 IO-APIC-fasteoi nvidia, eth0 17: 87810 0 0 0 0 0 0 0 IO-APIC-fasteoi firewire_ohci, hda_intel, nvidia 18: 242 0 0 0 0 0 0 0 IO-APIC-fasteoi hda_intel 23: 85925 0 0 0 0 0 0 0 IO-APIC-fasteoi ehci_hcd:usb5, ehci_hcd:usb6 40: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 41: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 42: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 43: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 44: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 45: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 46: 79853 0 0 0 0 0 0 0 PCI-MSI-edge ahci 48: 1 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 49: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 50: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 51: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 52: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 53: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 54: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 55: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 56: 1 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 57: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 58: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 59: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 60: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 61: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 62: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 63: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 64: 173506 0 0 0 0 0 0 0 PCI-MSI-edge hda_intel NMI: 482 89 25 13 277 24 11 10 Non-maskable interrupts LOC: 783857 194752 114133 70577 372438 179065 117179 162016 Local timer interrupts SPU: 0 0 0 0 0 0 0 0 Spurious interrupts PMI: 482 89 25 13 277 24 11 10 Performance monitoring interrupts IWI: 0 0 0 0 0 0 0 0 IRQ work interrupts RES: 131917 46750 7432 3291 150003 9576 3435 3067 Rescheduling interrupts CAL: 2759 6563 7150 6997 5387 7140 7269 6678 Function call interrupts TLB: 4396 2038 1336 492 5434 1896 1121 606 TLB shootdowns TRM: 0 0 0 0 0 0 0 0 Thermal event interrupts THR: 0 0 0 0 0 0 0 0 Threshold APIC interrupts MCE: 0 0 0 0 0 0 0 0 Machine check exceptions MCP: 37 37 37 37 37 37 37 37 Machine check polls ERR: 0 MIS: 0 Last but not least, right after boot-up those lines are usually present in dmesg: [ 18.367094] hda-intel: IRQ timing workaround is activated for card #1. Suggest a bigger bdl_pos_adj. [ 18.458859] hda-intel: IRQ timing workaround is activated for card #2. Suggest a bigger bdl_pos_adj. I'm not sure if it's related or a symptom of a bigger problem so I'm posting it just in case. I don't really know what other information might be of relevance here. Don't hesitate to ask for more in the comments.

    Read the article

  • Our embedded linux system won't recognize a USB Device if it is plugged in before powerup. Suggestions?

    - by Blaine
    We are developing on a small embedded device. This device us a gumstix overo board running OpenEmbedded linux. We have our development almost completely done, and have run into the strangest of bugs that we can't figure out. We have a USB Device (Spectrophotometer) that has a USB2.0 Connection and an external power supply for the light source. Typical behavior is that you plug in the power supply, then the USB connection to a host. When the usb connection is detected by the device, the device boots up and enables the light source and fan. The device is then able to be used by the host system. The problem is that if the device is plugged into the Gumstix before we turn on the Gumstix, the USB Device apparently is not probed by the system (and hence does not turn on). Under a normal situation, when the connection is initialized by plugging in the usb cable, the spectro turns itself on and becomes available to the system (this can be seen via "lsusb" typically). Neither of these things are happening. There is no device detected via "lsusb" and no dmesg errors of any kind that we can see. It is as if the device is not plugged in. The device does show up and work fine if we unplug the USB cable and plug it back in once the system is booted up. It turns on and shows up on the usb bus, and we can access it with our driver. On any other desktop or laptop, it does not matter if the host system is on or off when we plug in the spectrometer. This behavior is what I would consider to be "normal" - that the usb system is probed and initialized at boot time, and the usb devices come online. In other words, our system is fully functional as long as we plug in the usb device after the system is booted up. Unfortunately this isn't possible in our final product - everything comes on at once. Additional Info: 1) We have tried a flash drive attached to the system when the system is turned off. Booting up the system brings the flash drive online, as expected 2) There are no messages regarding the spectro or usb device (using dmesg). "lsusb" only lists the USB hubs / controllers. It is literally as if the device is not present and not plugged in. 3) We have tried a brand new image from gumstix and an older image from last year. Both images have this problem. This problem exists on all 3 gumstix devices we use. Does anyone have any suggestions? From what I can tell it isn't really possible to do a complete "reboot" of the usb system that is a complete emulation of "unplugging" and "replugging" a usb device. I feel like what is happening is that there is no initial probe on the usb bus that would trigger the usb handshaking, but this is somehow specific to the spectro. This seems to be a kernel issue or at least an issue in how the kernel is initializing the usb subsystem. I'm not really sure though. I have tried the gumstix mailing list, but there doesn't seem to be anyone who has seen this issue before. Any advice or suggestions on where to start looking would be fantastic. Thank you! Blaine output etc. $ uname -a Linux overo 2.6.33 #1 Tue Apr 27 08:35:38 PDT 2010 armv7l GNU/Linux When the system is up and running and spectro is plugged in (working as intended), this is lsusb: Bus 001 Device 116: ID 2457:1022 Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x2457 idProduct 0x1022 bcdDevice 0.02 iManufacturer 1 USB4000 1.01.11 iProduct 2 Ocean Optics USB4000 iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 46 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0x80 (Bus Powered) MaxPower 400mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 4 bInterfaceClass 255 Vendor Specific Class bInterfaceSubClass 0 bInterfaceProtocol 0 iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x86 EP 6 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0000 (Bus Powered) dmesg output: usb usb1: usb auto-resume hub 1-0:1.0: hub_resume usb usb2: usb auto-resume ehci-omap ehci-omap.0: resume root hub hub 1-0:1.0: state 7 ports 1 chg 0000 evt 0000 hub 2-0:1.0: hub_resume hub 2-0:1.0: state 7 ports 3 chg 0000 evt 0000 hub 1-0:1.0: hub_suspend usb usb1: bus auto-suspend hub 2-0:1.0: hub_suspend usb usb2: bus auto-suspend ehci-omap ehci-omap.0: suspend root hub usb usb2: usb resume ehci-omap ehci-omap.0: resume root hub hub 2-0:1.0: hub_resume ehci-omap ehci-omap.0: GetStatus port 2 status 001803 POWER sig=j CSC CONNECT hub 2-0:1.0: port 2: status 0501 change 0001 hub 2-0:1.0: state 7 ports 3 chg 0004 evt 0000 hub 2-0:1.0: port 2, status 0501, change 0000, 480 Mb/s ehci-omap ehci-omap.0: port 2 high speed ehci-omap ehci-omap.0: GetStatus port 2 status 001005 POWER sig=se0 PE CONNECT usb 2-2: new high speed USB device using ehci-omap and address 2 ehci-omap ehci-omap.0: port 2 high speed ehci-omap ehci-omap.0: GetStatus port 2 status 001005 POWER sig=se0 PE CONNECT usb 2-2: default language 0x0409 usb 2-2: udev 2, busnum 2, minor = 129 usb 2-2: New USB device found, idVendor=2457, idProduct=1022 usb 2-2: New USB device strings: Mfr=1, Product=2, SerialNumber=0 usb 2-2: Product: Ocean Optics USB4000 usb 2-2: Manufacturer: USB4000 1.01.11 usb 2-2: uevent usb 2-2: usb_probe_device usb 2-2: configuration #1 chosen from 1 choice usb 2-2: uevent usb 2-2: adding 2-2:1.0 (config #1, interface 0) usb 2-2:1.0: uevent drivers/usb/core/inode.c: creating file '002' dmesg has nothing to say, and lusb simply lists nothing else but the two default usb controllers / hubs if we plug the device in before the system is turned on.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • c#: sms appears to have been sent, but stuck in phone outbox

    - by I__
    i wrote code to send an SMS using my gsm phone which is attached to the computer through com port. the code is below. the problem is i do see that it is in the outbox of the phone and it actually appears to have been sent, but when i contact the recipient they say that i have not received the message. i test the phone, and i create and send a message using only the phone and it works perfectly, however when i do this with my code, it APPEARS to have been sent, and i am getting all the correct AT COMMAND responses from the phone, but the message is actually NOT sent. here is the code: using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.Threading; using System.IO.Ports; namespace WindowsFormsApplication1 { public partial class Form1 : Form { SerialPort serialPort1; int m_iTxtMsgState = 0; const int NUM_MESSAGE_STATES = 4; const string RESERVED_COM_1 = "COM1"; const string RESERVED_COM_4 = "COM4"; public Form1() { InitializeComponent(); this.Closing += new CancelEventHandler(Form1_Closing); } private void Form1_Load(object sender, EventArgs e) { serialPort1 = new SerialPort(GetUSBComPort()); if (serialPort1.IsOpen) { serialPort1.Close(); } serialPort1.Open(); //ThreadStart myThreadDelegate = new ThreadStart(ReceiveAndOutput); //Thread myThread = new Thread(myThreadDelegate); //myThread.Start(); this.serialPort1.DataReceived += new SerialDataReceivedEventHandler(sp_DataReceived); } private void Form1_Closing(object sender, System.ComponentModel.CancelEventArgs e) { serialPort1.Close(); } private void SendLine(string sLine) { serialPort1.Write(sLine); sLine = sLine.Replace("\u001A", ""); consoleOut.Text += sLine; } public void DoWork() { ProcessMessageState(); } public void ProcessMessageState() { switch (m_iTxtMsgState) { case 0: m_iTxtMsgState = 1; SendLine("AT\r\n"); //NOTE: SendLine must be the last thing called in all of these! break; case 1: m_iTxtMsgState = 2; SendLine("AT+CMGF=1\r\n"); break; case 2: m_iTxtMsgState = 3; SendLine("AT+CMGW=" + Convert.ToChar(34) + "+9737387467" + Convert.ToChar(34) + "\r\n"); break; case 3: m_iTxtMsgState = 4; SendLine("A simple demo of SMS text messaging." + Convert.ToChar(26)); break; case 4: m_iTxtMsgState = 5; break; case 5: m_iTxtMsgState = NUM_MESSAGE_STATES; break; } } private string GetStoredSMSID() { return null; } /* //i dont think this part does anything private void serialPort1_DataReceived_1(object sender, System.IO.Ports.SerialDataReceivedEventArgs e) { string response = serialPort1.ReadLine(); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); } */ void sp_DataReceived(object sender, SerialDataReceivedEventArgs e) { try { Thread.Sleep(500); char[] msg; msg = new char[613]; int iNumToRead = serialPort1.BytesToRead; serialPort1.Read(msg, 0, iNumToRead); string response = new string(msg); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); serialPort1.DiscardInBuffer(); if (m_iTxtMsgState == 4) { int pos_cmgw = response.IndexOf("+CMGW:"); string cmgw_num = response.Substring(pos_cmgw + 7, 4); SendLine("AT+CMSS=" + cmgw_num + "\r\n"); //stop listening to messages received } if (m_iTxtMsgState < NUM_MESSAGE_STATES) { ProcessMessageState(); } } catch { } } private void button1_Click(object sender, EventArgs e) { m_iTxtMsgState = 0; DoWork(); } private void button2_Click(object sender, EventArgs e) { string[] sPorts = SerialPort.GetPortNames(); foreach (string port in sPorts) { consoleOut.Text += port + "\r\n"; } } private string GetUSBComPort() { string[] sPorts = SerialPort.GetPortNames(); foreach (string port in sPorts) { if (port != RESERVED_COM_1 && port != RESERVED_COM_4) { return port; } } return null; } }

    Read the article

  • Windows 7 / Ubuntu Dualboot GRUB Problem.

    - by Tek
    I'd like to first say ahead of time that I'm running a RAID-0 Setup. 1.First of all, I'm glad Ubuntu 9.10 installed flawlessly and detected my RAID-0 setup just fine. The issue I'm having now is that I already had Windows 7 installed and made a small 12GB partition for Linux/Swap. I grabbed EasyBCD 2.0 to edit the W7 bootloader and configured it to use dual boot Grub2 because before it didn't even show the option for Ubuntu. The bootloader points to a file made in the windows directory made by EasyBCD called "C:\NST\AutoNeoGrub0.mbr" which is what I'm guessing grub is booting from. After that I got the option for booting Ubuntu. The problem is that it's sending me to the Grub prompt (probably because it's pointing to \NST|AutoNeoGrub0.mbr?), at first I didn't know what to do but I researched and have to type grub commands to manually boot into Ubuntu Linux. Ex: grubroot (hd0,4) grubkernel /boot/vmlinuz-2.6... root=/dev/disk/by-uuid/24624-2424... grubinitrd boot/initrd.img-2.6... grubboot After all that Ubuntu boots just fine, but how do I fix it permanently? Do I need to edit the bootloader manually (since Easy BCD "autoconfigures")? Some insight on this would rock! Also, it sucks to type the actual uuid since it's REALLY long. I tried getting the name of the drive via fdisk -l but since it's raid 0 I'm guessing I can't do that. How can I get a shorter name of the drive? like /dev/sda, /dev/sdb etc? I've also tried to update to the latest GRUB and I got this: Creating config file /etc/default/grub with new version Generating core.img error: cannot seek /dev/sdc' error: cannot seek/dev/sdc' grub-probe: error: no mapping exists for nvidia_dbedfcca5' Auto-detection of a filesystem module failed. Please specify the module with the option--modules' explicitly. dpkg: error processing grub-pc (--configure): subprocess installed post-installation script returned error exit status 1 dpkg: dependency problems prevent configuration of grub2: grub2 depends on grub-pc; however: Package grub-pc is not configured yet. dpkg: error processing grub2 (--configure): dependency problems - leaving unconfigured No apport report written because the error message indicates its a followup error from a previous failure. E: Sub-process /usr/bin/dpkg returned an error code (1) I've also tried: b@dnb:~$ sudo update-grub error: cannot seek /dev/sdc' error: cannot seek/dev/sdc' Generating grub.cfg ... Found linux image: /boot/vmlinuz-2.6.31-14-generic Found initrd image: /boot/initrd.img-2.6.31-14-generic error: cannot seek /dev/sdc' grub-probe: error: no mapping exists fornvidia_dbedfcca5' error: cannot seek /dev/sdc' grub-probe: error: no mapping exists fornvidia_dbedfcca5' Found memtest86+ image: /boot/memtest86+.bin Found Windows 7 (loader) on /dev/mapper/nvidia_dbedfcca1 error: cannot seek /dev/sdc' grub-probe: error: no mapping exists fornvidia_dbedfcca1' done To no avail. Any idea what I can do to fix this mess? :( Edit: This is my disk configuration. b@dnb:~$ sudo df -l Filesystem 1K-blocks Used Available Use% Mounted on /dev/mapper/nvidia_dbedfcca5 12302232 2744788 8932520 24% / udev 1030288 268 1030020 1% /dev none 1030288 964 1029324 1% /dev/shm none 1030288 92 1030196 1% /var/run none 1030288 0 1030288 0% /var/lock none 1030288 0 1030288 0% /lib/init/rw /dev/sr0 706532 706532 0 100% /media/cdrom0 Note: /dev/mapper/nvidia_dbedfcca5 is my Linux boot partition

    Read the article

  • The Execute SQL Task

    In this article we are going to take you through the Execute SQL Task in SQL Server Integration Services for SQL Server 2005 (although it appies just as well to SQL Server 2008).  We will be covering all the essentials that you will need to know to effectively use this task and make it as flexible as possible. The things we will be looking at are as follows: A tour of the Task. The properties of the Task. After looking at these introductory topics we will then get into some examples. The examples will show different types of usage for the task: Returning a single value from a SQL query with two input parameters. Returning a rowset from a SQL query. Executing a stored procedure and retrieveing a rowset, a return value, an output parameter value and passing in an input parameter. Passing in the SQL Statement from a variable. Passing in the SQL Statement from a file. Tour Of The Task Before we can start to use the Execute SQL Task in our packages we are going to need to locate it in the toolbox. Let's do that now. Whilst in the Control Flow section of the package expand your toolbox and locate the Execute SQL Task. Below is how we found ours. Now drag the task onto the designer. As you can see from the following image we have a validation error appear telling us that no connection manager has been assigned to the task. This can be easily remedied by creating a connection manager. There are certain types of connection manager that are compatable with this task so we cannot just create any connection manager and these are detailed in a few graphics time. Double click on the task itself to take a look at the custom user interface provided to us for this task. The task will open on the general tab as shown below. Take a bit of time to have a look around here as throughout this article we will be revisting this page many times. Whilst on the general tab, drop down the combobox next to the ConnectionType property. In here you will see the types of connection manager which this task will accept. As with SQL Server 2000 DTS, SSIS allows you to output values from this task in a number of formats. Have a look at the combobox next to the Resultset property. The major difference here is the ability to output into XML. If you drop down the combobox next to the SQLSourceType property you will see the ways in which you can pass a SQL Statement into the task itself. We will have examples of each of these later on but certainly when we saw these for the first time we were very excited. Next to the SQLStatement property if you click in the empty box next to it you will see ellipses appear. Click on them and you will see the very basic query editor that becomes available to you. Alternatively after you have specified a connection manager for the task you can click on the Build Query button to bring up a completely different query editor. This is slightly inconsistent. Once you've finished looking around the general tab, move on to the next tab which is the parameter mapping tab. We shall, again, be visiting this tab throughout the article but to give you an initial heads up this is where you define the input, output and return values from your task. Note this is not where you specify the resultset. If however you now move on to the ResultSet tab this is where you define what variable will receive the output from your SQL Statement in whatever form that is. Property Expressions are one of the most amazing things to happen in SSIS and they will not be covered here as they deserve a whole article to themselves. Watch out for this as their usefulness will astound you. For a more detailed discussion of what should be the parameter markers in the SQL Statements on the General tab and how to map them to variables on the Parameter Mapping tab see Working with Parameters and Return Codes in the Execute SQL Task. Task Properties There are two places where you can specify the properties for your task. One is in the task UI itself and the other is in the property pane which will appear if you right click on your task and select Properties from the context menu. We will be doing plenty of property setting in the UI later so let's take a moment to have a look at the property pane. Below is a graphic showing our properties pane. Now we shall take you through all the properties and tell you exactly what they mean. A lot of these properties you will see across all tasks as well as the package because of everything's base structure The Container. BypassPrepare Should the statement be prepared before sending to the connection manager destination (True/False) Connection This is simply the name of the connection manager that the task will use. We can get this from the connection manager tray at the bottom of the package. DelayValidation Really interesting property and it tells the task to not validate until it actually executes. A usage for this may be that you are operating on table yet to be created but at runtime you know the table will be there. Description Very simply the description of your Task. Disable Should the task be enabled or not? You can also set this through a context menu by right clicking on the task itself. DisableEventHandlers As a result of events that happen in the task, should the event handlers for the container fire? ExecValueVariable The variable assigned here will get or set the execution value of the task. Expressions Expressions as we mentioned earlier are a really powerful tool in SSIS and this graphic below shows us a small peek of what you can do. We select a property on the left and assign an expression to the value of that property on the right causing the value to be dynamically changed at runtime. One of the most obvious uses of this is that the property value can be built dynamically from within the package allowing you a great deal of flexibility FailPackageOnFailure If this task fails does the package? FailParentOnFailure If this task fails does the parent container? A task can he hosted inside another container i.e. the For Each Loop Container and this would then be the parent. ForcedExecutionValue This property allows you to hard code an execution value for the task. ForcedExecutionValueType What is the datatype of the ForcedExecutionValue? ForceExecutionResult Force the task to return a certain execution result. This could then be used by the workflow constraints. Possible values are None, Success, Failure and Completion. ForceExecutionValue Should we force the execution result? IsolationLevel This is the transaction isolation level of the task. IsStoredProcedure Certain optimisations are made by the task if it knows that the query is a Stored Procedure invocation. The docs say this will always be false unless the connection is an ADO connection. LocaleID Gets or sets the LocaleID of the container. LoggingMode Should we log for this container and what settings should we use? The value choices are UseParentSetting, Enabled and Disabled. MaximumErrorCount How many times can the task fail before we call it a day? Name Very simply the name of the task. ResultSetType How do you want the results of your query returned? The choices are ResultSetType_None, ResultSetType_SingleRow, ResultSetType_Rowset and ResultSetType_XML. SqlStatementSource Your Query/SQL Statement. SqlStatementSourceType The method of specifying the query. Your choices here are DirectInput, FileConnection and Variables TimeOut How long should the task wait to receive results? TransactionOption How should the task handle being asked to join a transaction? Usage Examples As we move through the examples we will only cover in them what we think you must know and what we think you should see. This means that some of the more elementary steps like setting up variables will be covered in the early examples but skipped and simply referred to in later ones. All these examples used the AventureWorks database that comes with SQL Server 2005. Returning a Single Value, Passing in Two Input Parameters So the first thing we are going to do is add some variables to our package. The graphic below shows us those variables having been defined. Here the CountOfEmployees variable will be used as the output from the query and EndDate and StartDate will be used as input parameters. As you can see all these variables have been scoped to the package. Scoping allows us to have domains for variables. Each container has a scope and remember a package is a container as well. Variable values of the parent container can be seen in child containers but cannot be passed back up to the parent from a child. Our following graphic has had a number of changes made. The first of those changes is that we have created and assigned an OLEDB connection manager to this Task ExecuteSQL Task Connection. The next thing is we have made sure that the SQLSourceType property is set to Direct Input as we will be writing in our statement ourselves. We have also specified that only a single row will be returned from this query. The expressions we typed in was: SELECT COUNT(*) AS CountOfEmployees FROM HumanResources.Employee WHERE (HireDate BETWEEN ? AND ?) Moving on now to the Parameter Mapping tab this is where we are going to tell the task about our input paramaters. We Add them to the window specifying their direction and datatype. A quick word here about the structure of the variable name. As you can see SSIS has preceeded the variable with the word user. This is a default namespace for variables but you can create your own. When defining your variables if you look at the variables window title bar you will see some icons. If you hover over the last one on the right you will see it says "Choose Variable Columns". If you click the button you will see a list of checkbox options and one of them is namespace. after checking this you will see now where you can define your own namespace. The next tab, result set, is where we need to get back the value(s) returned from our statement and assign to a variable which in our case is CountOfEmployees so we can use it later perhaps. Because we are only returning a single value then if you remember from earlier we are allowed to assign a name to the resultset but it must be the name of the column (or alias) from the query. A really cool feature of Business Intelligence Studio being hosted by Visual Studio is that we get breakpoint support for free. In our package we set a Breakpoint so we can break the package and have a look in a watch window at the variable values as they appear to our task and what the variable value of our resultset is after the task has done the assignment. Here's that window now. As you can see the count of employess that matched the data range was 2. Returning a Rowset In this example we are going to return a resultset back to a variable after the task has executed not just a single row single value. There are no input parameters required so the variables window is nice and straight forward. One variable of type object. Here is the statement that will form the soure for our Resultset. select p.ProductNumber, p.name, pc.Name as ProductCategoryNameFROM Production.ProductCategory pcJOIN Production.ProductSubCategory pscON pc.ProductCategoryID = psc.ProductCategoryIDJOIN Production.Product pON psc.ProductSubCategoryID = p.ProductSubCategoryID We need to make sure that we have selected Full result set as the ResultSet as shown below on the task's General tab. Because there are no input parameters we can skip the parameter mapping tab and move straight to the Result Set tab. Here we need to Add our variable defined earlier and map it to the result name of 0 (remember we covered this earlier) Once we run the task we can again set a breakpoint and have a look at the values coming back from the task. In the following graphic you can see the result set returned to us as a COM object. We can do some pretty interesting things with this COM object and in later articles that is exactly what we shall be doing. Return Values, Input/Output Parameters and Returning a Rowset from a Stored Procedure This example is pretty much going to give us a taste of everything. We have already covered in the previous example how to specify the ResultSet to be a Full result set so we will not cover it again here. For this example we are going to need 4 variables. One for the return value, one for the input parameter, one for the output parameter and one for the result set. Here is the statement we want to execute. Note how much cleaner it is than if you wanted to do it using the current version of DTS. In the Parameter Mapping tab we are going to Add our variables and specify their direction and datatypes. In the Result Set tab we can now map our final variable to the rowset returned from the stored procedure. It really is as simple as that and we were amazed at how much easier it is than in DTS 2000. Passing in the SQL Statement from a Variable SSIS as we have mentioned is hugely more flexible than its predecessor and one of the things you will notice when moving around the tasks and the adapters is that a lot of them accept a variable as an input for something they need. The ExecuteSQL task is no different. It will allow us to pass in a string variable as the SQL Statement. This variable value could have been set earlier on from inside the package or it could have been populated from outside using a configuration. The ResultSet property is set to single row and we'll show you why in a second when we look at the variables. Note also the SQLSourceType property. Here's the General Tab again. Looking at the variable we have in this package you can see we have only two. One for the return value from the statement and one which is obviously for the statement itself. Again we need to map the Result name to our variable and this can be a named Result Name (The column name or alias returned by the query) and not 0. The expected result into our variable should be the amount of rows in the Person.Contact table and if we look in the watch window we see that it is.   Passing in the SQL Statement from a File The final example we are going to show is a really interesting one. We are going to pass in the SQL statement to the task by using a file connection manager. The file itself contains the statement to run. The first thing we are going to need to do is create our file connection mananger to point to our file. Click in the connections tray at the bottom of the designer, right click and choose "New File Connection" As you can see in the graphic below we have chosen to use an existing file and have passed in the name as well. Have a look around at the other "Usage Type" values available whilst you are here. Having set that up we can now see in the connection manager tray our file connection manager sitting alongside our OLE-DB connection we have been using for the rest of these examples. Now we can go back to the familiar General Tab to set up how the task will accept our file connection as the source. All the other properties in this task are set up exactly as we have been doing for other examples depending on the options chosen so we will not cover them again here.   We hope you will agree that the Execute SQL Task has changed considerably in this release from its DTS predecessor. It has a lot of options available but once you have configured it a few times you get to learn what needs to go where. We hope you have found this article useful.

    Read the article

  • Dovecot: no auth attempts in 0 secs (IMAP protocol)

    - by Luca D'Amico
    I'm having a lot of problems configuring dovecot ony vps. I'm already able to send email using port 110 and to receive email using port 25, but I can't connect using port 993 and 995. I'm using self-signed ssl certificates. When I try to connect to 993 this error is logged: Jun 8 19:06:39 MY_HOSTNAME dovecot: imap-login: Disconnected (no auth attempts in 2 secs): user=<>, rip=MY_IP, lip=MY_VPS_IP, TLS, session=<MY_SESSION> When I try to connect to 995 here is the error log: Jun 8 19:08:17 MY_HOSTNAME dovecot: pop3-login: Disconnected (no auth attempts in 0 secs): user=<>, rip=MY_IP, lip=MY_VPS_IP, TLS: SSL_read() failed: error:14094416:SSL routines:SSL3_READ_BYTES:sslv3 alert certificate unknown: SSL alert number 46, session=<MY_SESSION> EDIT: I was able to fix this part by refreshing my mail client ssl cert. Anybody can help me please ? I'm stuck :/ Many thanks

    Read the article

  • Why does ssh hang after "debug1: loaded 3 keys"

    - by James Moore
    Trying to log in to an Amazon EC2 instance running Ubuntu 10.04.1. I can log in just fine, no issues. A different user, coming from a different network just gets this: OpenSSH_4.3p2, OpenSSL 0.9.8e-fips-rhel5 01 Jul 2008 debug1: Reading configuration data /etc/ssh/ssh_config debug1: Applying options for * debug1: Connecting to xxxx [xxxx] port 80. debug1: Connection established. debug1: identity file /.ssh/identity type -1 debug1: identity file /.ssh/id_rsa type -1 debug1: identity file /.ssh/id_dsa type -1 debug1: loaded 3 keys And then it hangs. We've tried running sshd on port 22 and port 80 I'm guessing that it's not a firewall problem since the verbose output reports that the connection is established. I don't see anything in /var/log/auth.log when the failing user connects. I do see entries when I log in successfully.

    Read the article

  • Mac does not recognize wide screen

    - by DUKE
    I am using Mac OS X Lion 10.7.4 on my Mac mini, with Samsung monitor with default resolution 1360 x 768. My Mac mini is connected to Samsung VGA port by Apple mini port to VGA adapter. When starting, my Mac does not recognize the wide screen resolution and always starts in a 4:3 mode, (but it shows 1360x768 as the resolution in the settings). I have to do one of the following actions to bring my Mac to the wide screen resolution: (1) Changing to some other resolution and bring back to the default resolution. (2) Unplug the Apple mini port to VGA adapter and re-connect again. (3) Put the machine to sleep and wake it up again. I am using Ubuntu 12.04, (in a different partition) in the same hardware, but Ubuntu is perfectly recognizing the display.

    Read the article

< Previous Page | 147 148 149 150 151 152 153 154 155 156 157 158  | Next Page >