Search Results

Search found 25093 results on 1004 pages for 'console output'.

Page 153/1004 | < Previous Page | 149 150 151 152 153 154 155 156 157 158 159 160  | Next Page >

  • Resource Acquisition is Initialization in C#

    - by codeWithoutFear
    Resource Acquisition Is Initialization (RAII) is a pattern I grew to love when working in C++.  It is perfectly suited for resource management such as matching all those pesky new's and delete's.  One of my goals was to limit the explicit deallocation statements I had to write.  Often these statements became victims of run-time control flow changes (i.e. exceptions, unhappy path) or development-time code refactoring. The beauty of RAII is realized by tying your resource creation (acquisition) to the construction (initialization) of a class instance.  Then bind the resource deallocation to the destruction of that instance.  That is well and good in a language with strong destructor semantics like C++, but languages like C# that run on garbage-collecting runtimes don't provide the same instance lifetime guarantees. Here is a class and sample that combines a few features of C# to provide an RAII-like solution: using System; namespace RAII { public class DisposableDelegate : IDisposable { private Action dispose; public DisposableDelegate(Action dispose) { if (dispose == null) { throw new ArgumentNullException("dispose"); } this.dispose = dispose; } public void Dispose() { if (this.dispose != null) { Action d = this.dispose; this.dispose = null; d(); } } } class Program { static void Main(string[] args) { Console.Out.WriteLine("Some resource allocated here."); using (new DisposableDelegate(() => Console.Out.WriteLine("Resource deallocated here."))) { Console.Out.WriteLine("Resource used here."); throw new InvalidOperationException("Test for resource leaks."); } } } } The output of this program is: Some resource allocated here. Resource used here. Unhandled Exception: System.InvalidOperationException: Test for resource leaks. at RAII.Program.Main(String[] args) in c:\Dev\RAII\RAII\Program.cs:line 40 Resource deallocated here. Code without fear! --Don

    Read the article

  • Simple Introduction to using the Enterprise Manager SOA/BPM Facade API by Jaideep Ganguli

    - by JuergenKress
    There may be times when you need to expose just a small section of what is displayed in the Enterprise Manager console for SOA/BPM (EM console). A simple example can be where stakeholders on the systems integration or customer teams want to monitor a dashboard of statistics on how many instances of a composite have been created and how many have faulted. You can see this in the EM, as shown below Some of these stakeholders may not have knowledge of  EM console and they just want a quick view into the statistics, without having to navigate EM. This post describes how to use the Oracle Fusion Middleware Infrastructure Management Java API  for Oracle SOA Suite (also called the Facade API)  to build a custom ADF page to display this information. If you want a quick introduction in using the Facade API, this post is for you. Read the complete article here. SOA & BPM Partner Community For regular information on Oracle SOA Suite become a member in the SOA & BPM Partner Community for registration please visit www.oracle.com/goto/emea/soa (OPN account required) If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Facebook Wiki Technorati Tags: Enterprise Manager,SOA Community,Oracle SOA,Oracle BPM,Community,OPN,Jürgen Kress

    Read the article

  • How to deal with elimination of duplicate logic vs. cost of complexity increase?

    - by Gabriel
    I just wrote some code that is very representative of a recurring theme (in my coding world lately): repeated logic leads to an instinct to eliminate duplication which results in something that is more complex the tradeoff seems wrong to me (the examples of the negative side aren't worth posting - but this is probably the 20th console utility I've written in the past 12 months). I'm curious if I'm missing some techniques or if this is really just on of those "experience tells you when to do what" type of issues. Here's the code... I'm tempted to leave it as is, even though there will be about 20 of those if-blocks when I'm done. static void Main(string[] sargs) { try { var urls = new DirectTrackRestUrls(); var restCall = new DirectTrackRestCall(); var logger = new ConsoleLogger(); Args args = (Args)Enum.Parse(typeof(Args), string.Join(",", sargs)); if (args.HasFlag(Args.Campaigns)) { var getter = new ResourceGetter(logger, urls.ListAdvertisers, restCall); restCall.UriVariables.Add("access_id", 1); getter.GotResource += new ResourceGetter.GotResourceEventHandler(getter_GotResource); getter.GetResources(); SaveResources(); } if (args.HasFlag(Args.Advertisers)) { var getter = new ResourceGetter(logger, urls.ListAdvertisers, restCall); restCall.UriVariables.Add("access_id", 1); getter.GotResource += new ResourceGetter.GotResourceEventHandler(getter_GotResource); getter.GetResources(); SaveResources(); } if (args.HasFlag(Args.CampaignGroups)) { var getter = new ResourceGetter(logger, urls.ListCampaignGroups, restCall); getter.GotResource += new ResourceGetter.GotResourceEventHandler(getter_GotResource); getter.GetResources(); SaveResources(); } } catch (Exception e) { Console.WriteLine(e.InnerException); Console.WriteLine(e.StackTrace); }

    Read the article

  • How to revert to Eclipse's old behavior when double-clicking on frames or windows, in Juno?

    - by mattquiros
    I find Eclipse Juno very counter-intuitive. In my workspace, I used to just have the package view at the left, my code on the right, and whenever I'm printing something in the console, that's only when the console frame shows up from the bottom right. When you double click on a particular window, it either only goes fullscreen within Eclipse, or back to its original size together with the size of the other frames. In Juno, however, it seems that frames are put on layers on top of each other. When I print something to the console, the output frame only shows up as a small, useless square to my right. When I double-click, it goes full screen. When I double-click again, it occupies the full right frame, hiding my code. I double-click again and it goes full screen, then it double-clicks before it shares the right frame with my code on top of it. Then when I minimize it, it goes to the side. Any way to go back to the good old days of Eclipse? Thanks.

    Read the article

  • Nodejs removing event listeners [migrated]

    - by JeffH
    Looking to get some help. I'm new to Nodejs and wondering if it is possible, to remove this custom event emitter. Most of this code comes from the Hand on nodejs by Pedro Teixeira. My function at the bottom is attempting to remove the custom event emitter you setup in the book. var util = require('util'); var EventEmitter = require('events').EventEmitter; // Pseudo-class named ticker that will self emit every 1 second. var Ticker = function() { var self = this; setInterval(function() { self.emit('tick'); }, 1000); }; // Bind the new EventEmitter to the sudo class. util.inherits(Ticker, EventEmitter); // call and instance of the ticker class to get the first // event started. Then let the event emitter run the infinante loop. var ticker = new Ticker(); ticker.on('tick', function() { console.log('Tick'); }); (function tock() { setInterval(function() { console.log('Tock'); EventEmitter.removeListener('Ticker',function() { console.log("Clocks Dead!"); }); }, 5000); })();

    Read the article

  • Issue updating domain name servers from BlueHost to AWS

    - by cowls
    I am trying to migrate my site hosting from bluehost to AWS cloud based service. I have the site up and running on AWS with an elastic IP configured, it loads fine when I specify the IP address in the browser. I have gone into Route 53 on the AWS console and created a "hosted zone" for the domain. I then created a new record set of type "A" using the IP address as the value. I have a domain name registered with bluehost. Ive logged into the bluehost account and updated the domain name servers to point to those specified in Route 53 in the AWS console. When I hit the IP address directly the site loads, however it doesn't load when using the domain name (I get a google chrome oops error page saying page is not found) I've tried using this site: http://dns.squish.net/ to debug but it seems to be giving me the correct results. fizaclegems.com 300 IN A 107.20.209.78 Where 107.20.209.78 matches the elastic IP configured in the AWS console. This is the result it gives for all 4 name servers. Am I missing a step here? Does anyone know what else I should be doing or looking for?

    Read the article

  • ubuntu 10.04: wlan0 No such device

    - by AodhanOL
    I am using a Dell xps l702x and I am using ubuntu 10.04 because I need to use f77 (don't ask) and I wasn't able to get it working on later versions of ubuntu. I cannot use the wifi at all. I have tried to fix it and have had limited success (changed the output from rfkill list all from Hard blocked: yes, to hard blocked: no). Here is the output from rfkill list all aodhan@aodhan-laptop:~$ rfkill list all 0: hci0: Bluetooth Soft blocked: no Hard blocked: no 1: dell-wifi: Wireless LAN Soft blocked: no Hard blocked: no 2: dell-bluetooth: Bluetooth Soft blocked: no Hard blocked: no Here is the output from iwconfig: aodhan@aodhan-laptop:~$ iwconfig lo no wireless extensions. eth0 no wireless extensions. pan0 no wireless extensions. And here is the output from ifconfig -a: aodhan@aodhan-laptop:~$ ifconfig -a eth0 Link encap:Ethernet HWaddr 5c:f9:dd:3d:f2:f7 inet addr:192.168.1.17 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::5ef9:ddff:fe3d:f2f7/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:3417 errors:0 dropped:0 overruns:0 frame:0 TX packets:2894 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3317567 (3.3 MB) TX bytes:505049 (505.0 KB) Interrupt:30 Base address:0x2000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:12 errors:0 dropped:0 overruns:0 frame:0 TX packets:12 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:720 (720.0 B) TX bytes:720 (720.0 B) pan0 Link encap:Ethernet HWaddr 7e:7e:e8:39:70:af BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) And finally, the output from lspci: 00:00.0 Host bridge: Intel Corporation Device 0104 (rev 09) 00:01.0 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:02.0 VGA compatible controller: Intel Corporation Device 0116 (rev 09) 00:16.0 Communication controller: Intel Corporation Cougar Point HECI Controller #1 (rev 04) 00:1a.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation Cougar Point High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 1 (rev b5) 00:1c.1 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 2 (rev b5) 00:1c.3 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 4 (rev b5) 00:1c.4 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 5 (rev b5) 00:1c.5 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 6 (rev b5) 00:1d.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation Device 1c4b (rev 05) 00:1f.2 SATA controller: Intel Corporation Cougar Point 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation Cougar Point SMBus Controller (rev 05) 01:00.0 VGA compatible controller: nVidia Corporation Device 1246 (rev a1) 03:00.0 Network controller: Intel Corporation Device 008a (rev 34) 04:00.0 USB Controller: NEC Corporation Device 0194 (rev 04) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) Please help me! Thank you in advance. Edit: Further info - this is a dual install with a windows 7 system as the other option. However, I can't access that until tomorrow (I won't have access to the windows 7 disc until then, and grub isn't letting me load it). Therefore, I can't be sure whether it still works on that or not. It used to, though.

    Read the article

  • apt-get update mdadm scary warnings

    - by user568829
    Just ran an apt-get update on one of my dedicated servers to be left with a relatively scary warning: Processing triggers for initramfs-tools ... update-initramfs: Generating /boot/initrd.img-2.6.26-2-686-bigmem W: mdadm: the array /dev/md/1 with UUID c622dd79:496607cf:c230666b:5103eba0 W: mdadm: is currently active, but it is not listed in mdadm.conf. if W: mdadm: it is needed for boot, then YOUR SYSTEM IS NOW UNBOOTABLE! W: mdadm: please inspect the output of /usr/share/mdadm/mkconf, compare W: mdadm: it to /etc/mdadm/mdadm.conf, and make the necessary changes. W: mdadm: the array /dev/md/2 with UUID 24120323:8c54087c:c230666b:5103eba0 W: mdadm: is currently active, but it is not listed in mdadm.conf. if W: mdadm: it is needed for boot, then YOUR SYSTEM IS NOW UNBOOTABLE! W: mdadm: please inspect the output of /usr/share/mdadm/mkconf, compare W: mdadm: it to /etc/mdadm/mdadm.conf, and make the necessary changes. W: mdadm: the array /dev/md/6 with UUID eef74de5:9267b2a1:c230666b:5103eba0 W: mdadm: is currently active, but it is not listed in mdadm.conf. if W: mdadm: it is needed for boot, then YOUR SYSTEM IS NOW UNBOOTABLE! W: mdadm: please inspect the output of /usr/share/mdadm/mkconf, compare W: mdadm: it to /etc/mdadm/mdadm.conf, and make the necessary changes. W: mdadm: the array /dev/md/5 with UUID 5d45b20c:04d8138f:c230666b:5103eba0 W: mdadm: is currently active, but it is not listed in mdadm.conf. if W: mdadm: it is needed for boot, then YOUR SYSTEM IS NOW UNBOOTABLE! W: mdadm: please inspect the output of /usr/share/mdadm/mkconf, compare W: mdadm: it to /etc/mdadm/mdadm.conf, and make the necessary changes. As instructed I inspected the output of /usr/share/mdadm/mkconf and compared with /etc/mdadm/mdadm.conf and they are quite different. Here is the /etc/mdadm/mdadm.conf contents: # mdadm.conf # # Please refer to mdadm.conf(5) for information about this file. # # by default, scan all partitions (/proc/partitions) for MD superblocks. # alternatively, specify devices to scan, using wildcards if desired. DEVICE partitions # auto-create devices with Debian standard permissions CREATE owner=root group=disk mode=0660 auto=yes # automatically tag new arrays as belonging to the local system HOMEHOST <system> # instruct the monitoring daemon where to send mail alerts MAILADDR root # definitions of existing MD arrays ARRAY /dev/md0 level=raid1 num-devices=2 UUID=b93b0b87:5f7c2c46:0043fca9:4026c400 ARRAY /dev/md1 level=raid1 num-devices=2 UUID=c0fa8842:e214fb1a:fad8a3a2:28f2aabc ARRAY /dev/md2 level=raid1 num-devices=2 UUID=cdc2a9a9:63bbda21:f55e806c:a5371897 ARRAY /dev/md3 level=raid1 num-devices=2 UUID=eca75495:9c9ce18c:d2bac587:f1e79d80 # This file was auto-generated on Wed, 04 Nov 2009 11:32:16 +0100 # by mkconf $Id$ And here is the out put from /usr/share/mdadm/mkconf # mdadm.conf # # Please refer to mdadm.conf(5) for information about this file. # # by default, scan all partitions (/proc/partitions) for MD superblocks. # alternatively, specify devices to scan, using wildcards if desired. DEVICE partitions # auto-create devices with Debian standard permissions CREATE owner=root group=disk mode=0660 auto=yes # automatically tag new arrays as belonging to the local system HOMEHOST <system> # instruct the monitoring daemon where to send mail alerts MAILADDR root # definitions of existing MD arrays ARRAY /dev/md1 UUID=c622dd79:496607cf:c230666b:5103eba0 ARRAY /dev/md2 UUID=24120323:8c54087c:c230666b:5103eba0 ARRAY /dev/md5 UUID=5d45b20c:04d8138f:c230666b:5103eba0 ARRAY /dev/md6 UUID=eef74de5:9267b2a1:c230666b:5103eba0 # This configuration was auto-generated on Sat, 25 Feb 2012 13:10:00 +1030 # by mkconf 3.1.4-1+8efb9d1+squeeze1 As I understand it I need to replace the four lines that start with 'ARRAY' in the /etc/mdadm/mdadm.conf file with the different four 'ARRAY' lines from the /usr/share/mdadm/mkconf output. When I did this and then ran update-initramfs -u there were no more warnings. Is what I have done above correct? I am now terrified of rebooting the server for fear it will not reboot and being a remote dedicated server this would certainly mean downtime and possibly would be expensive to get running again. FOLLOW UP (response to question): the output from mount: /dev/md1 on / type ext3 (rw,usrquota,grpquota) tmpfs on /lib/init/rw type tmpfs (rw,nosuid,mode=0755) proc on /proc type proc (rw,noexec,nosuid,nodev) sysfs on /sys type sysfs (rw,noexec,nosuid,nodev) udev on /dev type tmpfs (rw,mode=0755) tmpfs on /dev/shm type tmpfs (rw,nosuid,nodev) devpts on /dev/pts type devpts (rw,noexec,nosuid,gid=5,mode=620) /dev/md2 on /boot type ext2 (rw) /dev/md5 on /tmp type ext3 (rw) /dev/md6 on /home type ext3 (rw,usrquota,grpquota) mdadm --detail /dev/md0 mdadm: md device /dev/md0 does not appear to be active. mdadm --detail /dev/md1 /dev/md1: Version : 0.90 Creation Time : Sun Aug 14 09:43:08 2011 Raid Level : raid1 Array Size : 31463232 (30.01 GiB 32.22 GB) Used Dev Size : 31463232 (30.01 GiB 32.22 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 1 Persistence : Superblock is persistent Update Time : Sat Feb 25 14:03:47 2012 State : clean Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 UUID : c622dd79:496607cf:c230666b:5103eba0 Events : 0.24 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 17 1 active sync /dev/sdb1 mdadm --detail /dev/md2 /dev/md2: Version : 0.90 Creation Time : Sun Aug 14 09:43:09 2011 Raid Level : raid1 Array Size : 104320 (101.89 MiB 106.82 MB) Used Dev Size : 104320 (101.89 MiB 106.82 MB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 2 Persistence : Superblock is persistent Update Time : Sat Feb 25 13:20:20 2012 State : clean Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 UUID : 24120323:8c54087c:c230666b:5103eba0 Events : 0.30 Number Major Minor RaidDevice State 0 8 2 0 active sync /dev/sda2 1 8 18 1 active sync /dev/sdb2 mdadm --detail /dev/md3 mdadm: md device /dev/md3 does not appear to be active. mdadm --detail /dev/md5 /dev/md5: Version : 0.90 Creation Time : Sun Aug 14 09:43:09 2011 Raid Level : raid1 Array Size : 2104448 (2.01 GiB 2.15 GB) Used Dev Size : 2104448 (2.01 GiB 2.15 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 5 Persistence : Superblock is persistent Update Time : Sat Feb 25 14:09:03 2012 State : clean Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 UUID : 5d45b20c:04d8138f:c230666b:5103eba0 Events : 0.30 Number Major Minor RaidDevice State 0 8 5 0 active sync /dev/sda5 1 8 21 1 active sync /dev/sdb5 mdadm --detail /dev/md6 /dev/md6: Version : 0.90 Creation Time : Sun Aug 14 09:43:09 2011 Raid Level : raid1 Array Size : 453659456 (432.64 GiB 464.55 GB) Used Dev Size : 453659456 (432.64 GiB 464.55 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 6 Persistence : Superblock is persistent Update Time : Sat Feb 25 14:10:00 2012 State : active Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 UUID : eef74de5:9267b2a1:c230666b:5103eba0 Events : 0.31 Number Major Minor RaidDevice State 0 8 6 0 active sync /dev/sda6 1 8 22 1 active sync /dev/sdb6 FOLLOW UP 2 (response to question): Output from /etc/fstab /dev/md1 / ext3 defaults,usrquota,grpquota 1 1 devpts /dev/pts devpts mode=0620,gid=5 0 0 proc /proc proc defaults 0 0 #usbdevfs /proc/bus/usb usbdevfs noauto 0 0 /dev/cdrom /media/cdrom auto ro,noauto,user,exec 0 0 /dev/dvd /media/dvd auto ro,noauto,user,exec 0 0 # # # /dev/md2 /boot ext2 defaults 1 2 /dev/sda3 swap swap pri=42 0 0 /dev/sdb3 swap swap pri=42 0 0 /dev/md5 /tmp ext3 defaults 0 0 /dev/md6 /home ext3 defaults,usrquota,grpquota 1 2

    Read the article

  • Centos does not open port/s after the rule/s are appended

    - by Charlie Dyason
    So after some battling and struggling with the firewall, i see that I may be doing something or the firewall isnt responding correctly there is has a port filter that is blocking certain ports. by the way, I have combed the internet, posted on forums, done almost everything and now hence the website name "serverfault", is my last resort, I need help What I hoped to achieve is create a pptp server to connect to with windows/linux clients UPDATED @ bottom Okay, here is what I did: I made some changes to my iptables file, giving me endless issues and so I restored the iptables.old file contents of iptables.old: # Firewall configuration written by system-config-firewall # Manual customization of this file is not recommended. *filter :INPUT ACCEPT [0:0] :FORWARD ACCEPT [0:0] :OUTPUT ACCEPT [0:0] -A INPUT -m state --state ESTABLISHED,RELATED -j ACCEPT -A INPUT -p icmp -j ACCEPT -A INPUT -i lo -j ACCEPT -A INPUT -m state --state NEW -m tcp -p tcp --dport 22 -j ACCEPT -A INPUT -j REJECT --reject-with icmp-host-prohibited -A FORWARD -j REJECT --reject-with icmp-host-prohibited COMMIT after iptables.old restore(back to stock), nmap scan shows: nmap [server ip] Starting Nmap 6.00 ( nmap.org ) at 2013-11-01 13:54 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.014s latency). Not shown: 997 filtered ports PORT STATE SERVICE 22/tcp open ssh 113/tcp closed ident 8008/tcp open http Nmap done: 1 IP address (1 host up) scanned in 4.95 seconds if I append rule: (to accept all tcp ports incoming to server on interface eth0) iptables -A INPUT -i eth0 -m tcp -j ACCEPT nmap output: nmap [server ip] Starting Nmap 6.00 ( nmap.org ) at 2013-11-01 13:58 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.017s latency). Not shown: 858 filtered ports, 139 closed ports PORT STATE SERVICE 22/tcp open ssh 443/tcp open https 8008/tcp open http Nmap done: 1 IP address (1 host up) scanned in 3.77 seconds *notice it allows and opens port 443 but no other ports, and it removes port 113...? removing previous rule and if I append rule: (allow and open port 80 incoming to server on interface eth0) iptables -A INPUT -i eth0 -m tcp -p tcp --dport 80 -j ACCEPT nmap output: nmap [server ip] Starting Nmap 6.00 ( nmap.org ) at 2013-11-01 14:01 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.014s latency). Not shown: 996 filtered ports PORT STATE SERVICE 22/tcp open ssh 80/tcp closed http 113/tcp closed ident 8008/tcp open http Nmap done: 1 IP address (1 host up) scanned in 5.12 seconds *notice it removes port 443 and allows 80 but is closed without removing previous rule and if I append rule: (allow and open port 1723 incoming to server on interface eth0) iptables -A INPUT -i eth0 -m tcp -p tcp --dport 1723 -j ACCEPT nmap output: nmap [server ip] Starting Nmap 6.00 ( nmap.org ) at 2013-11-01 14:05 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.015s latency). Not shown: 996 filtered ports PORT STATE SERVICE 22/tcp open ssh 80/tcp closed http 113/tcp closed ident 8008/tcp open http Nmap done: 1 IP address (1 host up) scanned in 5.16 seconds *notice no change in ports opened or closed??? after removing rules: iptables -A INPUT -i eth0 -m tcp -p tcp --dport 80 -j ACCEPT iptables -A INPUT -i eth0 -m tcp -p tcp --dport 1723 -j ACCEPT nmap output: nmap [server ip] Starting Nmap 6.00 ( nmap.org ) at 2013-11-01 14:07 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.015s latency). Not shown: 998 filtered ports PORT STATE SERVICE 22/tcp open ssh 113/tcp closed ident Nmap done: 1 IP address (1 host up) scanned in 5.15 seconds and returning rule: (to accept all tcp ports incoming to server on interface eth0) iptables -A INPUT -i eth0 -m tcp -j ACCEPT nmap output: nmap [server ip] Starting Nmap 6.00 ( nmap.org ) at 2013-11-01 14:07 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.017s latency). Not shown: 858 filtered ports, 139 closed ports PORT STATE SERVICE 22/tcp open ssh 443/tcp open https 8008/tcp open http Nmap done: 1 IP address (1 host up) scanned in 3.87 seconds notice the eth0 changes the 999 filtered ports to 858 filtered ports, 139 closed ports QUESTION: why cant I allow and/or open a specific port, eg. I want to allow and open port 443, it doesnt allow it, or even 1723 for pptp, why am I not able to??? sorry for the layout, the editor was give issues (aswell... sigh) UPDATE @Madhatter comment #1 thank you madhatter in my iptables file: # Firewall configuration written by system-config-firewall # Manual customization of this file is not recommended. *filter :INPUT ACCEPT [0:0] :FORWARD ACCEPT [0:0] :OUTPUT ACCEPT [0:0] -A INPUT -m state --state ESTABLISHED,RELATED -j ACCEPT -A INPUT -p icmp -j ACCEPT -A INPUT -i eth0 -j ACCEPT -A INPUT -i lo -j ACCEPT -A INPUT -m state --state NEW -m tcp -p tcp --dport 22 -j ACCEPT # ----------all rules mentioned in post where added here ONLY!!!---------- -A INPUT -j REJECT --reject-with icmp-host-prohibited -A FORWARD -j REJECT --reject-with icmp-host-prohibited COMMIT if I want to allow and open port 1723 (or edit iptables to allow a pptp connection from remote pc), what changes would I make? (please bear with me, my first time working with servers, etc.) Update MadHatter comment #2 iptables -L -n -v --line-numbers Chain INPUT (policy ACCEPT 0 packets, 0 bytes) num pkts bytes target prot opt in out source destination 1 9 660 ACCEPT all -- * * 0.0.0.0/0 0.0.0.0/0 state RELATED,ESTABLISHED 2 0 0 ACCEPT icmp -- * * 0.0.0.0/0 0.0.0.0/0 3 0 0 ACCEPT all -- eth0 * 0.0.0.0/0 0.0.0.0/0 4 0 0 ACCEPT all -- lo * 0.0.0.0/0 0.0.0.0/0 5 0 0 ACCEPT tcp -- * * 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:22 6 0 0 REJECT all -- * * 0.0.0.0/0 0.0.0.0/0 reject-with icmp-host-prohibited Chain FORWARD (policy ACCEPT 0 packets, 0 bytes) num pkts bytes target prot opt in out source destination 1 0 0 REJECT all -- * * 0.0.0.0/0 0.0.0.0/0 reject-with icmp-host-prohibited Chain OUTPUT (policy ACCEPT 6 packets, 840 bytes) num pkts bytes target prot opt in out source destination just on a personal note, madhatter, thank you for the support , I really appreciate it! UPDATE MadHatter comment #3 here are the interfaces ifconfig eth0 Link encap:Ethernet HWaddr 00:1D:D8:B7:1F:DC inet addr:[server ip] Bcast:[server ip x.x.x].255 Mask:255.255.255.0 inet6 addr: fe80::21d:d8ff:feb7:1fdc/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:36692 errors:0 dropped:0 overruns:0 frame:0 TX packets:4247 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:2830372 (2.6 MiB) TX bytes:427976 (417.9 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) tun0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 inet addr:10.8.0.1 P-t-P:10.8.0.2 Mask:255.255.255.255 UP POINTOPOINT RUNNING NOARP MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) remote nmap nmap -p 1723 [server ip] Starting Nmap 6.00 ( http://nmap.org ) at 2013-11-01 16:17 SAST Nmap scan report for server.address.net ([server ip]) Host is up (0.017s latency). PORT STATE SERVICE 1723/tcp filtered pptp Nmap done: 1 IP address (1 host up) scanned in 0.51 seconds local nmap nmap -p 1723 localhost Starting Nmap 5.51 ( http://nmap.org ) at 2013-11-01 16:19 SAST Nmap scan report for localhost (127.0.0.1) Host is up (0.000058s latency). Other addresses for localhost (not scanned): 127.0.0.1 PORT STATE SERVICE 1723/tcp open pptp Nmap done: 1 IP address (1 host up) scanned in 0.11 seconds UPDATE MadHatter COMMENT POST #4 I apologize, if there might have been any confusion, i did have the rule appended: (only after 3rd post) iptables -A INPUT -p tcp --dport 1723 -j ACCEPT netstat -apn|grep -w 1723 tcp 0 0 0.0.0.0:1723 0.0.0.0:* LISTEN 1142/pptpd There are not VPN's and firewalls between the server and "me" UPDATE MadHatter comment #5 So here is an intersting turn of events: I booted into windows 7, created a vpn connection, went through the verfication username & pword - checking the sstp then checking pptp (went through that very quickly which meeans there is no problem), but on teh verfication of username and pword (before registering pc on network), it got stuck, gave this error Connection failed with error 2147943625 The remote computer refused the network connection netstat -apn | grep -w 1723 before connecting: netstat -apn |grep -w 1723 tcp 0 0 0.0.0.0:1723 0.0.0.0:* LISTEN 1137/pptpd after the error came tried again: netstat -apn |grep -w 1723 tcp 0 0 0.0.0.0:1723 0.0.0.0:* LISTEN 1137/pptpd tcp 0 0 41.185.26.238:1723 41.13.212.47:49607 TIME_WAIT - I do not know what it means but seems like there is progress..., any thoughts???

    Read the article

  • Set width of Button in Android

    - by Mohit Deshpande
    How can I set a fixed width for an Android button? Everytime I try to set a fixed width it fills the current parent (the RelativeView). Here is my XML: <?xml version="1.0" encoding="utf-8"?> <RelativeLayout android:id="@+id/relativelayout" android:layout_width="fill_parent" android:layout_height="fill_parent" xmlns:android="http://schemas.android.com/apk/res/android"> <EditText android:layout_height="wrap_content" android:editable="false" android:layout_width="fill_parent" android:id="@+id/output"></EditText> <Button android:layout_height="wrap_content" android:id="@+id/Button01" android:layout_below="@id/output" android:text="7" android:layout_width="wrap_content"></Button> <Button android:layout_below="@id/output" android:layout_height="wrap_content" android:layout_width="wrap_content" android:id="@+id/Button02" android:layout_toRightOf="@+id/Button01" android:text="8"></Button> <Button android:layout_below="@id/output" android:layout_height="wrap_content" android:layout_width="wrap_content" android:id="@+id/Button03" android:layout_toRightOf="@+id/Button02" android:text="9"></Button> </RelativeLayout> How would I give it a FIXED width?

    Read the article

  • JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue

    - by John-Brown.Evans
    JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue ol{margin:0;padding:0} .c11_4{vertical-align:top;width:129.8pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c9_4{vertical-align:top;width:207pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt}.c14{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c17_4{vertical-align:top;width:129.8pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c7_4{vertical-align:top;width:130pt;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c19_4{vertical-align:top;width:468pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c22_4{background-color:#ffffff} .c20_4{list-style-type:disc;margin:0;padding:0} .c6_4{font-size:8pt;font-family:"Courier New"} .c24_4{color:inherit;text-decoration:inherit} .c23_4{color:#1155cc;text-decoration:underline} .c0_4{height:11pt;direction:ltr} .c10_4{font-size:10pt;font-family:"Courier New"} .c3_4{padding-left:0pt;margin-left:36pt} .c18_4{font-size:8pt} .c8_4{text-align:center} .c12_4{background-color:#ffff00} .c2_4{font-weight:bold} .c21_4{background-color:#00ff00} .c4_4{line-height:1.0} .c1_4{direction:ltr} .c15_4{background-color:#f3f3f3} .c13_4{font-family:"Courier New"} .c5_4{font-style:italic} .c16_4{border-collapse:collapse} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:bold;padding-bottom:0pt} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:11pt;font-family:"Arial";padding-bottom:0pt} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:10pt;font-family:"Arial";padding-bottom:0pt} This post continues the series of JMS articles which demonstrate how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue In this example we will create a BPEL process which will write (enqueue) a message to a JMS queue using a JMS adapter. The JMS adapter will enqueue the full XML payload to the queue. This sample will use the following WebLogic Server objects. The first two, the Connection Factory and JMS Queue, were created as part of the first blog post in this series, JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g. If you haven't created those objects yet, please see that post for details on how to do so. The Connection Pool will be created as part of this example. Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue 1. Verify Connection Factory and JMS Queue As mentioned above, this example uses a WLS Connection Factory called TestConnectionFactory and a JMS queue TestJMSQueue. As these are prerequisites for this example, let us verify they exist. Log in to the WebLogic Server Administration Console. Select Services > JMS Modules > TestJMSModule You should see the following objects: If not, or if the TestJMSModule is missing, please see the abovementioned article and create these objects before continuing. 2. Create a JMS Adapter Connection Pool in WebLogic Server The BPEL process we are about to create uses a JMS adapter to write to the JMS queue. The JMS adapter is deployed to the WebLogic server and needs to be configured to include a connection pool which references the connection factory associated with the JMS queue. In the WebLogic Server Console Go to Deployments > Next and select (click on) the JmsAdapter Select Configuration > Outbound Connection Pools and expand oracle.tip.adapter.jms.IJmsConnectionFactory. This will display the list of connections configured for this adapter. For example, eis/aqjms/Queue, eis/aqjms/Topic etc. These JNDI names are actually quite confusing. We are expecting to configure a connection pool here, but the names refer to queues and topics. One would expect these to be called *ConnectionPool or *_CF or similar, but to conform to this nomenclature, we will call our entry eis/wls/TestQueue . This JNDI name is also the name we will use later, when creating a BPEL process to access this JMS queue! Select New, check the oracle.tip.adapter.jms.IJmsConnectionFactory check box and Next. Enter JNDI Name: eis/wls/TestQueue for the connection instance, then press Finish. Expand oracle.tip.adapter.jms.IJmsConnectionFactory again and select (click on) eis/wls/TestQueue The ConnectionFactoryLocation must point to the JNDI name of the connection factory associated with the JMS queue you will be writing to. In our example, this is the connection factory called TestConnectionFactory, with the JNDI name jms/TestConnectionFactory.( As a reminder, this connection factory is contained in the JMS Module called TestJMSModule, under Services > Messaging > JMS Modules > TestJMSModule which we verified at the beginning of this document. )Enter jms/TestConnectionFactory  into the Property Value field for Connection Factory Location. After entering it, you must press Return/Enter then Save for the value to be accepted. If your WebLogic server is running in Development mode, you should see the message that the changes have been activated and the deployment plan successfully updated. If not, then you will manually need to activate the changes in the WebLogic server console. Although the changes have been activated, the JmsAdapter needs to be redeployed in order for the changes to become effective. This should be confirmed by the message Remember to update your deployment to reflect the new plan when you are finished with your changes as can be seen in the following screen shot: The next step is to redeploy the JmsAdapter.Navigate back to the Deployments screen, either by selecting it in the left-hand navigation tree or by selecting the “Summary of Deployments” link in the breadcrumbs list at the top of the screen. Then select the checkbox next to JmsAdapter and press the Update button On the Update Application Assistant page, select “Redeploy this application using the following deployment files” and press Finish. After a few seconds you should get the message that the selected deployments were updated. The JMS adapter configuration is complete and it can now be used to access the JMS queue. To summarize: we have created a JMS adapter connection pool connector with the JNDI name jms/TestConnectionFactory. This is the JNDI name to be accessed by a process such as a BPEL process, when using the JMS adapter to access the previously created JMS queue with the JNDI name jms/TestJMSQueue. In the following step, we will set up a BPEL process to use this JMS adapter to write to the JMS queue. 3. Create a BPEL Composite with a JMS Adapter Partner Link This step requires that you have a valid Application Server Connection defined in JDeveloper, pointing to the application server on which you created the JMS Queue and Connection Factory. You can create this connection in JDeveloper under the Application Server Navigator. Give it any name and be sure to test the connection before completing it. This sample will use the connection name jbevans-lx-PS5, as that is the name of the connection pointing to my SOA PS5 installation. When using a JMS adapter from within a BPEL process, there are various configuration options, such as the operation type (consume message, produce message etc.), delivery mode and message type. One of these options is the choice of the format of the JMS message payload. This can be structured around an existing XSD, in which case the full XML element and tags are passed, or it can be opaque, meaning that the payload is sent as-is to the JMS adapter. In the case of an XSD-based message, the payload can simply be copied to the input variable of the JMS adapter. In the case of an opaque message, the JMS adapter’s input variable is of type base64binary. So the payload needs to be converted to base64 binary first. I will go into this in more detail in a later blog entry. This sample will pass a simple message to the adapter, based on the following simple XSD file, which consists of a single string element: stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.example.org" targetNamespace="http://www.example.org" elementFormDefault="qualified" <xsd:element name="exampleElement" type="xsd:string"> </xsd:element> </xsd:schema> The following steps are all executed in JDeveloper. The SOA project will be created inside a JDeveloper Application. If you do not already have an application to contain the project, you can create a new one via File > New > General > Generic Application. Give the application any name, for example JMSTests and, when prompted for a project name and type, call the project JmsAdapterWriteWithXsd and select SOA as the project technology type. If you already have an application, continue below. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterWriteSchema. When prompted for the composite type, choose Composite With BPEL Process. When prompted for the BPEL Process, name it JmsAdapterWriteSchema too and choose Synchronous BPEL Process as the template. This will create a composite with a BPEL process and an exposed SOAP service. Double-click the BPEL process to open and begin editing it. You should see a simple BPEL process with a Receive and Reply activity. As we created a default process without an XML schema, the input and output variables are simple strings. Create an XSD File An XSD file is required later to define the message format to be passed to the JMS adapter. In this step, we create a simple XSD file, containing a string variable and add it to the project. First select the xsd item in the left-hand navigation tree to ensure that the XSD file is created under that item. Select File > New > General > XML and choose XML Schema. Call it stringPayload.xsd and when the editor opens, select the Source view. then replace the contents with the contents of the stringPayload.xsd example above and save the file. You should see it under the xsd item in the navigation tree. Create a JMS Adapter Partner Link We will create the JMS adapter as a service at the composite level. If it is not already open, double-click the composite.xml file in the navigator to open it. From the Component Palette, drag a JMS adapter over onto the right-hand swim lane, under External References. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterWrite Oracle Enterprise Messaging Service (OEMS): Oracle Weblogic JMS AppServer Connection: Use an existing application server connection pointing to the WebLogic server on which the above JMS queue and connection factory were created. You can use the “+” button to create a connection directly from the wizard, if you do not already have one. This example uses a connection called jbevans-lx-PS5. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Produce Message Operation Name: Produce_message Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created earlier. JNDI Name: The JNDI name to use for the JMS connection. This is probably the most important step in this exercise and the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) MessagesURL: We will use the XSD file we created earlier, stringPayload.xsd to define the message format for the JMS adapter. Press the magnifying glass icon to search for schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string. Press Next and Finish, which will complete the JMS Adapter configuration. Wire the BPEL Component to the JMS Adapter In this step, we link the BPEL process/component to the JMS adapter. From the composite.xml editor, drag the right-arrow icon from the BPEL process to the JMS adapter’s in-arrow. This completes the steps at the composite level. 4. Complete the BPEL Process Design Invoke the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterWriteSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterWrite partner link under one of the two swim lanes. We want it in the right-hand swim lane. If JDeveloper displays it in the left-hand lane, right-click it and choose Display > Move To Opposite Swim Lane. An Invoke activity is required in order to invoke the JMS adapter. Drag an Invoke activity between the Receive and Reply activities. Drag the right-hand arrow from the Invoke activity to the JMS adapter partner link. This will open the Invoke editor. The correct default values are entered automatically and are fine for our purposes. We only need to define the input variable to use for the JMS adapter. By pressing the green “+” symbol, a variable of the correct type can be auto-generated, for example with the name Invoke1_Produce_Message_InputVariable. Press OK after creating the variable. ( For some reason, while I was testing this, the JMS Adapter moved back to the left-hand swim lane again after this step. There is no harm in leaving it there, but I find it easier to follow if it is in the right-hand lane, because I kind-of think of the message coming in on the left and being routed through the right. But you can follow your personal preference here.) Assign Variables Drag an Assign activity between the Receive and Invoke activities. We will simply copy the input variable to the JMS adapter and, for completion, so the process has an output to print, again to the process’s output variable. Double-click the Assign activity and create two Copy rules: for the first, drag Variables > inputVariable > payload > client:process > client:input_string to Invoke1_Produce_Message_InputVariable > body > ns2:exampleElement for the second, drag the same input variable to outputVariable > payload > client:processResponse > client:result This will create two copy rules, similar to the following: Press OK. This completes the BPEL and Composite design. 5. Compile and Deploy the Composite We won’t go into too much detail on how to compile and deploy. In JDeveloper, compile the process by pressing the Make or Rebuild icons or by right-clicking the project name in the navigator and selecting Make... or Rebuild... If the compilation is successful, deploy it to the SOA server connection defined earlier. (Right-click the project name in the navigator, select Deploy to Application Server, choose the application server connection, choose the partition on the server (usually default) and press Finish. You should see the message ---- Deployment finished. ---- in the Deployment frame, if the deployment was successful. 6. Test the Composite This is the exciting part. Open two tabs in your browser and log in to the WebLogic Administration Console in one tab and the Enterprise Manager 11g Fusion Middleware Control (EM) for your SOA installation in the other. We will use the Console to monitor the messages being written to the queue and the EM to execute the composite. In the Console, go to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. Note the number of messages under Messages Current. In the EM, go to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterWriteSchema [1.0], then press the Test button. Under Input Arguments, enter any string into the text input field for the payload, for example Test Message then press Test Web Service. If the instance is successful you should see the same text in the Response message, “Test Message”. In the Console, refresh the Monitoring screen to confirm a new message has been written to the queue. Check the checkbox and press Show Messages. Click on the newest message and view its contents. They should include the full XML of the entered payload. 7. Troubleshooting If you get an exception similar to the following at runtime ... BINDING.JCA-12510 JCA Resource Adapter location error. Unable to locate the JCA Resource Adapter via .jca binding file element The JCA Binding Component is unable to startup the Resource Adapter specified in the element: location='eis/wls/QueueTest'. The reason for this is most likely that either 1) the Resource Adapters RAR file has not been deployed successfully to the WebLogic Application server or 2) the '' element in weblogic-ra.xml has not been set to eis/wls/QueueTest. In the last case you will have to add a new WebLogic JCA connection factory (deploy a RAR). Please correct this and then restart the Application Server at oracle.integration.platform.blocks.adapter.fw.AdapterBindingException. createJndiLookupException(AdapterBindingException.java:130) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.createJCAConnectionFactory (JCAConnectionManager.java:1387) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.newPoolObject (JCAConnectionManager.java:1285) ... then this is very likely due to an incorrect JNDI name entered for the JMS Connection in the JMS Adapter Wizard. Recheck those steps. The error message prints the name of the JNDI name used. In this example, it was incorrectly entered as eis/wls/QueueTest instead of eis/wls/TestQueue. This concludes this example. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • Issue with Sharepoint 2010 application page

    - by Matt Moriarty
    I am relatively new to Sharepoint and am using version 2010. I am having a problem with the following code in an application page I am trying to build: using System; using Microsoft.SharePoint; using Microsoft.SharePoint.WebControls; using System.Text; using Microsoft.SharePoint.Administration; using Microsoft.Office.Server; using Microsoft.Office.Server.UserProfiles; using Microsoft.SharePoint.Utilities; namespace SharePointProject5.Layouts.SharePointProject5 { public partial class ApplicationPage1 : LayoutsPageBase { protected void Page_Load(object sender, EventArgs e) { SPContext context = SPContext.Current; StringBuilder output = new StringBuilder(); using(SPSite site = context.Site) using (SPWeb web = site.AllWebs["BDC_SQL"]) { UserProfileManager upmanager = new UserProfileManager(ServerContext.GetContext(site)); string ListMgr = ""; string ADMgr = ""; bool allowUpdates = web.AllowUnsafeUpdates; web.AllowUnsafeUpdates = true; web.Update(); SPListCollection listcollection = web.Lists; SPList list = listcollection["BDC_SQL"]; foreach (SPListItem item in list.Items) { output.AppendFormat("<br>From List - Name & manager: {0} , {1}", item["ADName"], item["Manager_ADName"]); UserProfile uProfile = upmanager.GetUserProfile(item["ADName"].ToString()); output.AppendFormat("<br>From Prof - Name & manager: {0} , {1}", uProfile[PropertyConstants.DistinguishedName], uProfile[PropertyConstants.Manager]); ListMgr = item["Manager_ADName"].ToString(); ADMgr = Convert.ToString(uProfile[PropertyConstants.Manager]); if (ListMgr != ADMgr) { output.AppendFormat("<br>This record requires updating from {0} to {1}", uProfile[PropertyConstants.Manager], item["Manager_ADName"]); uProfile[PropertyConstants.Manager].Value = ListMgr; uProfile.Commit(); output.AppendFormat("<br>This record has had its manager updated"); } else { output.AppendFormat("<br>This record does not need to be updated"); } } web.AllowUnsafeUpdates = allowUpdates; web.Update(); } Label1.Text = output.ToString(); } } } Everything worked fine up until I added in the 'uProfile.Commit();' line. Now I am getting the following error message: Microsoft.SharePoint.SPException was unhandled by user code Message=Updates are currently disallowed on GET requests. To allow updates on a GET, set the 'AllowUnsafeUpdates' property on SPWeb. Source=Microsoft.SharePoint ErrorCode=-2130243945 NativeErrorMessage=FAILED hr detected (hr = 0x80004005) NativeStackTrace="" StackTrace: at Microsoft.SharePoint.SPGlobal.HandleComException(COMException comEx) at Microsoft.SharePoint.Library.SPRequest.ValidateFormDigest(String bstrUrl, String bstrListName) at Microsoft.SharePoint.SPWeb.ValidateFormDigest() at Microsoft.Office.Server.UserProfiles.UserProfile.UpdateBlobProfile() at Microsoft.Office.Server.UserProfiles.UserProfile.Commit() at SharePointProject5.Layouts.SharePointProject5.ApplicationPage1.Page_Load(Object sender, EventArgs e) at System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) at System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) at System.Web.UI.Control.OnLoad(EventArgs e) at Microsoft.SharePoint.WebControls.UnsecuredLayoutsPageBase.OnLoad(EventArgs e) at Microsoft.SharePoint.WebControls.LayoutsPageBase.OnLoad(EventArgs e) at System.Web.UI.Control.LoadRecursive() at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) InnerException: System.Runtime.InteropServices.COMException Message=<nativehr>0x80004005</nativehr><nativestack></nativestack>Updates are currently disallowed on GET requests. To allow updates on a GET, set the 'AllowUnsafeUpdates' property on SPWeb. Source="" ErrorCode=-2130243945 StackTrace: at Microsoft.SharePoint.Library.SPRequestInternalClass.ValidateFormDigest(String bstrUrl, String bstrListName) at Microsoft.SharePoint.Library.SPRequest.ValidateFormDigest(String bstrUrl, String bstrListName) InnerException: I have tried to rectify this by adding in code to allow the unsafe updates but I still get this error. Does anyone have any guidance for me? It would be much appreciated. Thanks in advance, Matt.

    Read the article

  • How to send messages between c++ .dll and C# app using named pipe?

    - by Gal
    I'm making an injected .dll written in C++, and I want to communicate with a C# app using named pipes. Now, I am using the built in System.IO.Pipe .net classes in the C# app, and I'm using the regular functions in C++. I don't have much experience in C++ (Read: This is my first C++ code..), tho I'm experienced in C#. It seems that the connection with the server and the client is working, the only problem is the messaged aren't being send. I tried making the .dll the server, the C# app the server, making the pipe direction InOut (duplex) but none seems to work. When I tried to make the .dll the server, which sends messages to the C# app, the code I used was like this: DWORD ServerCreate() // function to create the server and wait till it successfully creates it to return. { hPipe = CreateNamedPipe(pipename,//The unique pipe name. This string must have the following form: \\.\pipe\pipename PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_NOWAIT, //write and read and return right away PIPE_UNLIMITED_INSTANCES,//The maximum number of instances that can be created for this pipe 4096 , // output time-out 4096 , // input time-out 0,//client time-out NULL); if(hPipe== INVALID_HANDLE_VALUE) { return 1;//failed } else return 0;//success } void SendMsg(string msg) { DWORD cbWritten; WriteFile(hPipe,msg.c_str(), msg.length()+1, &cbWritten,NULL); } void ProccesingPipeInstance() { while(ServerCreate() == 1)//if failed { Sleep(1000); } //if created success, wait to connect ConnectNamedPipe(hPipe, NULL); for(;;) { SendMsg("HI!"); if( ConnectNamedPipe(hPipe, NULL)==0) if(GetLastError()==ERROR_NO_DATA) { DebugPrintA("previous closed,ERROR_NO_DATA"); DisconnectNamedPipe(hPipe); ConnectNamedPipe(hPipe, NULL); } Sleep(1000); } And the C# cliend like this: static void Main(string[] args) { Console.WriteLine("Hello!"); using (var pipe = new NamedPipeClientStream(".", "HyprPipe", PipeDirection.In)) { Console.WriteLine("Created Client!"); Console.Write("Connecting to pipe server in the .dll ..."); pipe.Connect(); Console.WriteLine("DONE!"); using (var pr = new StreamReader(pipe)) { string t; while ((t = pr.ReadLine()) != null) { Console.WriteLine("Message: {0}",t); } } } } I see that the C# client connected to the .dll, but it won't receive any message.. I tried doing it the other way around, as I said before, and trying to make the C# send messages to the .dll, which would show them in a message box. The .dll was injected and connected to the C# server, but when It received a message it just crashed the application it was injected to. Please help me, or guide me on how to use named pipes between C++ and C# app

    Read the article

  • Is there a C pre-processor which eliminates #ifdef blocks based on values defined/undefined?

    - by Jonathan Leffler
    Original Question What I'd like is not a standard C pre-processor, but a variation on it which would accept from somewhere - probably the command line via -DNAME1 and -UNAME2 options - a specification of which macros are defined, and would then eliminate dead code. It may be easier to understand what I'm after with some examples: #ifdef NAME1 #define ALBUQUERQUE "ambidextrous" #else #define PHANTASMAGORIA "ghostly" #endif If the command were run with '-DNAME1', the output would be: #define ALBUQUERQUE "ambidextrous" If the command were run with '-UNAME1', the output would be: #define PHANTASMAGORIA "ghostly" If the command were run with neither option, the output would be the same as the input. This is a simple case - I'd be hoping that the code could handle more complex cases too. To illustrate with a real-world but still simple example: #ifdef USE_VOID #ifdef PLATFORM1 #define VOID void #else #undef VOID typedef void VOID; #endif /* PLATFORM1 */ typedef void * VOIDPTR; #else typedef mint VOID; typedef char * VOIDPTR; #endif /* USE_VOID */ I'd like to run the command with -DUSE_VOID -UPLATFORM1 and get the output: #undef VOID typedef void VOID; typedef void * VOIDPTR; Another example: #ifndef DOUBLEPAD #if (defined NT) || (defined OLDUNIX) #define DOUBLEPAD 8 #else #define DOUBLEPAD 0 #endif /* NT */ #endif /* !DOUBLEPAD */ Ideally, I'd like to run with -UOLDUNIX and get the output: #ifndef DOUBLEPAD #if (defined NT) #define DOUBLEPAD 8 #else #define DOUBLEPAD 0 #endif /* NT */ #endif /* !DOUBLEPAD */ This may be pushing my luck! Motivation: large, ancient code base with lots of conditional code. Many of the conditions no longer apply - the OLDUNIX platform, for example, is no longer made and no longer supported, so there is no need to have references to it in the code. Other conditions are always true. For example, features are added with conditional compilation so that a single version of the code can be used for both older versions of the software where the feature is not available and newer versions where it is available (more or less). Eventually, the old versions without the feature are no longer supported - everything uses the feature - so the condition on whether the feature is present or not should be removed, and the 'when feature is absent' code should be removed too. I'd like to have a tool to do the job automatically because it will be faster and more reliable than doing it manually (which is rather critical when the code base includes 21,500 source files). (A really clever version of the tool might read #include'd files to determine whether the control macros - those specified by -D or -U on the command line - are defined in those files. I'm not sure whether that's truly helpful except as a backup diagnostic. Whatever else it does, though, the pseudo-pre-processor must not expand macros or include files verbatim. The output must be source similar to, but usually simpler than, the input code.) Status Report (one year later) After a year of use, I am very happy with 'sunifdef' recommended by the selected answer. It hasn't made a mistake yet, and I don't expect it to. The only quibble I have with it is stylistic. Given an input such as: #if (defined(A) && defined(B)) || defined(C) || (defined(D) && defined(E)) and run with '-UC' (C is never defined), the output is: #if defined(A) && defined(B) || defined(D) && defined(E) This is technically correct because '&&' binds tighter than '||', but it is an open invitation to confusion. I would much prefer it to include parentheses around the sets of '&&' conditions, as in the original: #if (defined(A) && defined(B)) || (defined(D) && defined(E)) However, given the obscurity of some of the code I have to work with, for that to be the biggest nit-pick is a strong compliment; it is valuable tool to me. The New Kid on the Block Having checked the URL for inclusion in the information above, I see that (as predicted) there is an new program called Coan that is the successor to 'sunifdef'. It is available on SourceForge and has been since January 2010. I'll be checking it out...further reports later this year, or maybe next year, or sometime, or never.

    Read the article

  • Propel-load-data is causing an error

    - by Jon Winstanley
    I am trying to load fixtures but myproject is erroring at the CLI and starting the indexer process. I have tried: Rebuilding the schema and model Emptying the database and starting again Clearing the cache Validating the YML file and trying much simpler data-dumps My platform is Symfony 1.0 on Windows Some also seems to have had the same issue in the past. C:\web\my_project>symfony propel-load-data backend >> propel load data from "C:\web\my_project\data\fixtures" PHP Warning: session_start(): Cannot send session cookie - headers already sent by (output started at C:\php\PEAR\symfony\vendor\pake\pakeFunction.php:366) in C:\php\PEAR\symfony\storage\sfSessionStorage.class.php on line 77 Warning: session_start(): Cannot send session cookie - headers already sent by (output started at C:\php\PEAR\symfony\vendor\pake\pakeFunction.php:366) in C:\php\PEAR\symfony\storage\sfSessionStorage.class.php on line 77 PHP Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at C:\php\PEAR\symfony\vendor\pake\pakeFunction.php:366) in C:\php\PEAR\symfony\storage\sfSessionStorage.class.php on line 77 Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at C:\php\PEAR\symfony\vendor\pake\pakeFunction.php:366) in C:\php\PEAR\symfony\storage\sfSessionStorage.class.php on line 77

    Read the article

  • Issuing Current Time Increments in StreamInsight (A Practical Example)

    The issuing of a Current Time Increment, Cti, in StreamInsight is very definitely one of the most important concepts to learn if you want your Streams to be responsive. A full discussion of how to issue Ctis is beyond the scope of this article but a very good explanation in addition to Books Online can be found in these three articles by a member of the StreamInsight team at Microsoft, Ciprian Gerea. Time in StreamInsight Series http://blogs.msdn.com/b/streaminsight/archive/2010/07/23/time-in-streaminsight-i.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/07/30/time-in-streaminsight-ii.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/08/03/time-in-streaminsight-iii.aspx A lot of the problems I see with unresponsive or stuck streams on the MSDN Forums are to do with how Ctis are enqueued or in a lot of cases not enqueued. If you enqueue events and never enqueue a Cti then StreamInsight will be perfectly happy. You, on the other hand, will never see data on the output as you have not told StreamInsight to flush the stream. This article deals with a specific implementation problem I had recently whilst working on a StreamInsight project. I look at some possible options and discuss why they would not work before showing the way I solved the problem. The stream of data I was dealing with on this project was very bursty that is to say when events were flowing they came through very quickly and in large numbers (1000 events/sec), but when the stream calmed down it could be a few seconds between each event. When enqueuing events into the StreamInsight engne it is best practice to do so with a StartTime that is given to you by the system producing the event . StreamInsight processes events and it doesn't matter whether those events are being pushed into the engine by a source system or the events are being read from something like a flat file in a directory somewhere. You can apply the same logic and temporal algebra to both situations. Reading from a file is an excellent example of where the time of the event on the source itself is very important. We could be reading that file a long time after it was written. Being able to read the StartTime from the events allows us to define windows that will hold the correct sets of events. I was able to do this with my stream but this is where my problems started. Below is a very simple script to create a SQL Server table and populate it with sample data that will show exactly the problem I had. CREATE TABLE [dbo].[t] ( [c1] [int] PRIMARY KEY, [c2] [datetime] NULL ) INSERT t VALUES (1,'20100810'),(2,'20100810'),(3,'20100810') Column c2 defines the StartTime of the event on the source and as you can see the values in all 3 rows of data is the same. If we read Ciprian’s articles we know that we can define how Ctis get injected into the stream in 3 different places The Stream Definition The Input Factory The Input Adapter I personally have always been a fan of enqueing Ctis through the factory. Below is code typical of what I would use to do this On the class itself I do some inheriting public class SimpleInputFactory : ITypedInputAdapterFactory<SimpleInputConfig>, ITypedDeclareAdvanceTimeProperties<SimpleInputConfig> And then I implement the following function public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.FromTicks(-1)), AdvanceTimePolicy.Adjust); } The configInfo .CtiFrequency property is a value I pass through to define after how many events I want a Cti to be injected and this in turn will flush through the stream of data. I usually pass a value of 1 for this setting. The second parameter determines the CTI timestamp in terms of a delay relative to the events. -1 ticks in the past results in 1 tick in the future, i.e., ahead of the event. The problem with this method though is that if consecutive events have the same StartTime then only one of those events will be enqueued. In this example I use the following to define how I assign the StartTime of my events currEvent.StartTime = (DateTimeOffset)dt.c2; If I go ahead and run my StreamInsight process with this configuration i can see on the output adapter that two events have been removed To see this in a little more depth I can use the StreamInsight Debugger and see what happens internally. What is happening here is that the first event arrives and a Cti is injected with a time of 1 tick after the StartTime of that event (Also the EndTime of the event). The second event arrives and it has a StartTime of before the Cti and even though we specified AdvanceTimePolicy.Adjust on the factory we know that a point event can never be adjusted like this and the event is dropped. The same happens for the third event as well (The second and third events get trumped by the Cti). For a more detailed discussion of why this happens look here http://www.sqlis.com/sqlis/post/AdvanceTimePolicy-and-Point-Event-Streams-In-StreamInsight.aspx We end up with a single event being pushed into the output adapter and our result now makes sense. The next way I tried to solve this problem by changing the value of the second parameter to TimeSpan.Zero Here is how my factory code now looks public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.Zero), AdvanceTimePolicy.Adjust); } What I am doing here is declaring a policy that says inject a Cti together with every event and stamp it with a StartTime that is equal to the start time of the event itself (TimeSpan.Zero). This method has plus points as well as a downside. The upside is that no events will be lost by having the same StartTime as previous events. The Downside is that because the Cti is declared with the StartTime of the event itself then it does not actually flush that particular event because in the StreamInsight algebra, a Cti commits only those events that occurred strictly before them. To flush the events we need a Cti to be enqueued with a greater StartTime than the events themselves. Here is what happened when I ran this configuration As you can see all we got through was the Cti and none of the events. The debugger output shows the stamps on the Cti and the events themselves. Because the Cti issued has the same timestamp (StartTime) as the events then none of the events get flushed. I was nearly there but not quite. Because my stream was bursty it was possible that the next event would not come along for a few seconds and this was far too long for an event to be enqueued and not be flushed to the output adapter. I needed another solution. Two possible solutions crossed my mind although only one of them made sense when I explored it some more. Where multiple events have the same StartTime I could add 1 tick to the first event, two to the second, three to third etc thereby giving them unique StartTime values. Add a timer to manually inject Ctis The problem with the first implementation is that I would be giving the events a new StartTime. This would cause me the following problems If I want to define windows over the stream then some events may not be captured in the right windows and therefore any calculations on those windows I did would be wrong What would happen if we had 10,000 events with the same StartTime? I would enqueue them with StartTime + n ticks. Along comes a genuine event with a StartTime of the very first event + 1 tick. It is now too far in the past as far as my stream is concerned and it would be dropped. Not what I would want to do at all. I decided then to look at the Timer based solution I created a timer on my input adapter that elapsed every 200ms. private Timer tmr; public SimpleInputAdapter(SimpleInputConfig configInfo) { ctx = new SimpleTimeExtractDataContext(configInfo.ConnectionString); this.configInfo = configInfo; tmr = new Timer(200); tmr.Elapsed += new ElapsedEventHandler(t_Elapsed); tmr.Enabled = true; } void t_Elapsed(object sender, ElapsedEventArgs e) { ts = DateTime.Now - dtCtiIssued; if (ts.TotalMilliseconds >= 200 && TimerIssuedCti == false) { EnqueueCtiEvent(System.DateTime.Now.AddTicks(-100)); TimerIssuedCti = true; } }   In the t_Elapsed event handler I find out the difference in time between now and when the last event was processed (dtCtiIssued). I then check to see if that is greater than or equal to 200ms and if the last issuing of a Cti was done by the timer or by a genuine event (TimerIssuedCti). If I didn’t do this check then I would enqueue a Cti every time the timer elapsed which is not something I wanted. If the difference between the two times is greater than or equal to 500ms and the last event enqueued was by a real event then I issue a Cti through the timer to flush the event Queue, otherwise I do nothing. When I enqueue the Ctis into my stream in my ProduceEvents method I also set the values of dtCtiIssued and TimerIssuedCti   currEvent = CreateInsertEvent(); currEvent.StartTime = (DateTimeOffset)dt.c2; TimerIssuedCti = false; dtCtiIssued = currEvent.StartTime; If I go ahead and run this configuration I see the following in my output. As we can see the first Cti gets enqueued as before but then another is enqueued by the timer and because this has a later timestamp it flushes the enqueued events through the engine. Conclusion Hopefully this has shown how the enqueuing of Ctis can have a dramatic effect on the responsiveness of your output in StreamInsight. Understanding the temporal nature of the product is for me one of the most important things you can learn. I have attached my solution for the demos. It is all in one project and testing each variation is a simple matter of commenting and un-commenting the parts in the code we have been dealing with here.

    Read the article

  • installed openstack using devstack install shell script but getting 500 error when i try opening dashboard

    - by Arvind
    I followed the instructions at http://devstack.org/guides/single-machine.html to install OpenStack. I first installed Ubuntu on my Windows 7 PC using the officially supported Windows installer for Ubuntu 12.04 LTS. And after that I followed the instructions at above page to install OpenStack. As per instructions, I should be able to access the dashboard aka Horizon, at http://192.168.1.4/ (thats the IP of the PC on which I installed Ubuntu-OpenStack). However I am getting a 500 error web page when I open that. How do I resolve this error? I want to set up a dev environment for OpenStack. For your ref, the whole error message is given now-- FilterError at / /usr/bin/env: node: No such file or directory Request Method: GET Request URL: http://192.168.1.4/ Django Version: 1.4.2 Exception Type: FilterError Exception Value: /usr/bin/env: node: No such file or directory Exception Location: /usr/local/lib/python2.7/dist-packages/compressor/filters/base.py in input, line 133 Python Executable: /usr/bin/python Python Version: 2.7.3 Python Path: ['/opt/stack/horizon/openstack_dashboard/wsgi/../..', '/opt/stack/python-keystoneclient', '/opt/stack/python-novaclient', '/opt/stack/python-openstackclient', '/opt/stack/keystone', '/opt/stack/glance', '/opt/stack/python-glanceclient/setuptools_git-0.4.2-py2.7.egg', '/opt/stack/python-glanceclient', '/opt/stack/nova', '/opt/stack/horizon', '/opt/stack/cinder', '/opt/stack/python-cinderclient', '/usr/local/lib/python2.7/dist-packages', '/usr/lib/python2.7', '/usr/lib/python2.7/plat-linux2', '/usr/lib/python2.7/lib-tk', '/usr/lib/python2.7/lib-old', '/usr/lib/python2.7/lib-dynload', '/usr/lib/python2.7/dist-packages', '/usr/lib/python2.7/dist-packages/PIL', '/usr/lib/python2.7/dist-packages/gst-0.10', '/usr/lib/python2.7/dist-packages/gtk-2.0', '/usr/lib/pymodules/python2.7', '/usr/lib/python2.7/dist-packages/ubuntu-sso-client', '/usr/lib/python2.7/dist-packages/ubuntuone-client', '/usr/lib/python2.7/dist-packages/ubuntuone-control-panel', '/usr/lib/python2.7/dist-packages/ubuntuone-couch', '/usr/lib/python2.7/dist-packages/ubuntuone-storage-protocol', '/opt/stack/horizon/openstack_dashboard'] Server time: Sat, 27 Oct 2012 08:43:29 +0000 Error during template rendering In template /opt/stack/horizon/openstack_dashboard/templates/_stylesheets.html, error at line 3 /usr/bin/env: node: No such file or directory 1 {% load compress %} 2 3 {% compress css %} 4 <link href='{{ STATIC_URL }}dashboard/less/horizon.less' type='text/less' media='screen' rel='stylesheet' /> 5 {% endcompress %} 6 7 <link rel="shortcut icon" href="{{ STATIC_URL }}dashboard/img/favicon.ico"/> 8 Also, the traceback is now given below-- Environment: Request Method: GET Request URL: http://192.168.1.4/ Django Version: 1.4.2 Python Version: 2.7.3 Installed Applications: ('openstack_dashboard', 'django.contrib.contenttypes', 'django.contrib.auth', 'django.contrib.sessions', 'django.contrib.messages', 'django.contrib.staticfiles', 'django.contrib.humanize', 'compressor', 'horizon', 'openstack_dashboard.dashboards.project', 'openstack_dashboard.dashboards.admin', 'openstack_dashboard.dashboards.settings', 'openstack_auth') Installed Middleware: ('django.middleware.common.CommonMiddleware', 'django.middleware.csrf.CsrfViewMiddleware', 'django.contrib.sessions.middleware.SessionMiddleware', 'django.contrib.auth.middleware.AuthenticationMiddleware', 'django.contrib.messages.middleware.MessageMiddleware', 'horizon.middleware.HorizonMiddleware', 'django.middleware.doc.XViewMiddleware', 'django.middleware.locale.LocaleMiddleware') Template error: In template /opt/stack/horizon/openstack_dashboard/templates/_stylesheets.html, error at line 3 /usr/bin/env: node: No such file or directory 1 : {% load compress %} 2 : 3 : {% compress css %} 4 : <link href='{{ STATIC_URL }}dashboard/less/horizon.less' type='text/less' media='screen' rel='stylesheet' /> 5 : {% endcompress %} 6 : 7 : <link rel="shortcut icon" href="{{ STATIC_URL }}dashboard/img/favicon.ico"/> 8 : Traceback: File "/usr/local/lib/python2.7/dist-packages/django/core/handlers/base.py" in get_response 111. response = callback(request, *callback_args, **callback_kwargs) File "/usr/local/lib/python2.7/dist-packages/django/views/decorators/vary.py" in inner_func 36. response = func(*args, **kwargs) File "/opt/stack/horizon/openstack_dashboard/wsgi/../../openstack_dashboard/views.py" in splash 38. return shortcuts.render(request, 'splash.html', {'form': form}) File "/usr/local/lib/python2.7/dist-packages/django/shortcuts/__init__.py" in render 44. return HttpResponse(loader.render_to_string(*args, **kwargs), File "/usr/local/lib/python2.7/dist-packages/django/template/loader.py" in render_to_string 176. return t.render(context_instance) File "/usr/local/lib/python2.7/dist-packages/django/template/base.py" in render 140. return self._render(context) File "/usr/local/lib/python2.7/dist-packages/django/template/base.py" in _render 134. return self.nodelist.render(context) File "/usr/local/lib/python2.7/dist-packages/django/template/base.py" in render 823. bit = self.render_node(node, context) File "/usr/local/lib/python2.7/dist-packages/django/template/debug.py" in render_node 74. return node.render(context) File "/usr/local/lib/python2.7/dist-packages/django/template/loader_tags.py" in render 155. return self.render_template(self.template, context) File "/usr/local/lib/python2.7/dist-packages/django/template/loader_tags.py" in render_template 137. output = template.render(context) File "/usr/local/lib/python2.7/dist-packages/django/template/base.py" in render 140. return self._render(context) File "/usr/local/lib/python2.7/dist-packages/django/template/base.py" in _render 134. return self.nodelist.render(context) File "/usr/local/lib/python2.7/dist-packages/django/template/base.py" in render 823. bit = self.render_node(node, context) File "/usr/local/lib/python2.7/dist-packages/django/template/debug.py" in render_node 74. return node.render(context) File "/usr/local/lib/python2.7/dist-packages/compressor/templatetags/compress.py" in render 147. return self.render_compressed(context, self.kind, self.mode, forced=forced) File "/usr/local/lib/python2.7/dist-packages/compressor/templatetags/compress.py" in render_compressed 107. rendered_output = self.render_output(compressor, mode, forced=forced) File "/usr/local/lib/python2.7/dist-packages/compressor/templatetags/compress.py" in render_output 119. return compressor.output(mode, forced=forced) File "/usr/local/lib/python2.7/dist-packages/compressor/css.py" in output 51. ret.append(subnode.output(*args, **kwargs)) File "/usr/local/lib/python2.7/dist-packages/compressor/css.py" in output 53. return super(CssCompressor, self).output(*args, **kwargs) File "/usr/local/lib/python2.7/dist-packages/compressor/base.py" in output 230. content = self.filter_input(forced) File "/usr/local/lib/python2.7/dist-packages/compressor/base.py" in filter_input 192. for hunk in self.hunks(forced): File "/usr/local/lib/python2.7/dist-packages/compressor/base.py" in hunks 167. precompiled, value = self.precompile(value, **options) File "/usr/local/lib/python2.7/dist-packages/compressor/base.py" in precompile 210. command=command, filename=filename).input(**kwargs) File "/usr/local/lib/python2.7/dist-packages/compressor/filters/base.py" in input 133. raise FilterError(err) Exception Type: FilterError at / Exception Value: /usr/bin/env: node: No such file or directory

    Read the article

  • Filter rows on the basis of "First Name" + "Last Name" in SQL

    - by Raghav Khunger
    Hi, I have a user table in my database which contains two columns FirstName and LastName. Now in my front end there is a textbox to filter out the users from this table. Let's suppose I am taking that input from the front end in the form of a input parameter "@SEARCHKEYWORD". I have created a sample below: DECLARE @Test TABLE ([ID] INT IDENTITY, [FNAME] NVARCHAR(100), [LNAME] NVARCHAR(100) ) INSERT INTO @Test( FNAME, LNAME ) SELECT 'John','Resig' UNION ALL SELECT 'Dave','Ward' UNION ALL SELECT 'Peter','Smith' UNION ALL SELECT 'Dave','Smith' UNION ALL SELECT 'Girija','Acharya' UNION ALL SELECT 'Devendra', 'Gujel' UNION ALL SELECT 'Arjit', 'Gupta' DECLARE @SEARCHKEYWORD NVARCHAR(100) SELECT * FROM @Test WHERE FNAME +' '+ LNAME LIKE @SEARCHKEYWORD i.e. so far I have thought of this query to filter out the rows but it is not giving the desired results: SELECT * FROM @Test WHERE FNAME +' '+ LNAME LIKE @SEARCHKEYWORD Here are the desired outputs which I needed for the inputs mentioned below: --WHEN @SEARCHKEYWORD='John Resig' --Desired OUTPUT: the row which contains 'John','Resig' --WHEN @SEARCHKEYWORD='Ac' --Desired OUTPUT: the row which contains 'Girija','Acharya' --WHEN @SEARCHKEYWORD='Smith' --Desired OUTPUT: the row which contains 'Peter','Smith' and 'Dave','Smith' --WHEN @SEARCHKEYWORD='g' --Desired OUTPUT: the row which contains 'Devendra', 'Gujel' and 'Arjit', 'Gupta' --WHEN @SEARCHKEYWORD='Smith' --Desired OUTPUT: the row which contains 'Peter','Smith' and 'Dave','Smith'

    Read the article

  • Injecting generics with Guice

    - by paradigmatic
    I am trying to migrate a small project, replacing some factories with Guice (it is my first Guice trial). However, I am stuck when trying to inject generics. I managed to extract a small toy example with two classes and a module: import com.google.inject.Inject; public class Console<T> { private final StringOutput<T> out; @Inject public Console(StringOutput<T> out) { this.out = out; } public void print(T t) { System.out.println(out.converter(t)); } } public class StringOutput<T> { public String converter(T t) { return t.toString(); } } import com.google.inject.AbstractModule; import com.google.inject.Guice; import com.google.inject.Injector; import com.google.inject.TypeLiteral; public class MyModule extends AbstractModule { @Override protected void configure() { bind(StringOutput.class); bind(Console.class); } public static void main(String[] args) { Injector injector = Guice.createInjector( new MyModule() ); StringOutput<Integer> out = injector.getInstance(StringOutput.class); System.out.println( out.converter(12) ); Console<Double> cons = injector.getInstance(Console.class); cons.print(123.0); } } When I run this example, all I got is: Exception in thread "main" com.google.inject.CreationException: Guice creation errors: 1) playground.StringOutput<T> cannot be used as a key; It is not fully specified. at playground.MyModule.configure(MyModule.java:15) 1 error at com.google.inject.internal.Errors.throwCreationExceptionIfErrorsExist(Errors.java:354) at com.google.inject.InjectorBuilder.initializeStatically(InjectorBuilder.java:152) at com.google.inject.InjectorBuilder.build(InjectorBuilder.java:105) at com.google.inject.Guice.createInjector(Guice.java:92) I tried looking for the error message, but without finding any useful hints. Further on the Guice FAQ I stumble upon a question about how to inject generics. I tried to add the following binding in the configure method: bind(new TypeLiteral<StringOutput<Double>>() {}).toInstance(new StringOutput<Double>()); But without success (same error message). Can someone explain me the error message and provide me some tips ? Thanks.

    Read the article

  • .NET 1.0 ThreadPool Question

    - by dotnet-practitioner
    I am trying to spawn a thread to take care of DoWork task that should take less than 3 seconds. Inside DoWork its taking 15 seconds. I want to abort DoWork and transfer the control back to main thread. I have copied the code as follows and its not working. Instead of aborting DoWork, it still finishes DoWork and then transfers the control back to main thread. What am I doing wrong? class Class1 { /// <summary> /// The main entry point for the application. /// </summary> /// private static System.Threading.ManualResetEvent[] resetEvents; [STAThread] static void Main(string[] args) { resetEvents = new ManualResetEvent[1]; int i = 0; resetEvents[i] = new ManualResetEvent(false); ThreadPool.QueueUserWorkItem(new WaitCallback(DoWork),(object)i); Thread.CurrentThread.Name = "main thread"; Console.WriteLine("[{0}] waiting in the main method", Thread.CurrentThread.Name); DateTime start = DateTime.Now; DateTime end ; TimeSpan span = DateTime.Now.Subtract(start); //abort dowork method if it takes more than 3 seconds //and transfer control to the main thread. do { if (span.Seconds < 3) WaitHandle.WaitAll(resetEvents); else resetEvents[0].Set(); end = DateTime.Now; span = end.Subtract(start); }while (span.Seconds < 2); Console.WriteLine(span.Seconds); Console.WriteLine("[{0}] all done in the main method",Thread.CurrentThread.Name); Console.ReadLine(); } static void DoWork(object o) { int index = (int)o; Thread.CurrentThread.Name = "do work thread"; //simulate heavy duty work. Thread.Sleep(15000); //work is done.. resetEvents[index].Set(); Console.WriteLine("[{0}] do work finished",Thread.CurrentThread.Name); } }

    Read the article

  • Does writing data to server using Java URL class require response from server?

    - by gigadot
    I am trying to upload files using Java URL class and I have found a previous question on stack-overflow which explains very well about the details, so I try to follow it. And below is my code adopted from the sniplet given in the answer. My problem is that if I don't make a call to one of connection.getResponseCode() or connection.getInputStream() or connection.getResponseMessage() or anything which is related to reponse from the server, the request will never be sent to server. Why do I need to do this? Or is there any way to write the data without getting the response? P.S. I have developed a server-side uploading servlet which accepts multipart/form-data and save it to files using FileUpload. It is stable and definitely working without any problem so this is not where my problem is generated. import java.io.Closeable; import java.io.File; import java.io.FileInputStream; import java.io.IOException; import java.io.OutputStream; import java.io.PrintWriter; import java.net.HttpURLConnection; import java.net.URL; import org.apache.commons.io.IOUtils; public class URLUploader { public static void closeQuietly(Closeable... objs) { for (Closeable closeable : objs) { IOUtils.closeQuietly(closeable); } } public static void main(String[] args) throws IOException { File textFile = new File("D:\\file.zip"); String boundary = Long.toHexString(System.currentTimeMillis()); // Just generate some unique random value. HttpURLConnection connection = (HttpURLConnection) new URL("http://localhost:8080/upslet/upload").openConnection(); connection.setDoOutput(true); connection.setRequestProperty("Content-Type", "multipart/form-data; boundary=" + boundary); OutputStream output = output = connection.getOutputStream(); PrintWriter writer = writer = new PrintWriter(output, true); // Send text file. writer.println("--" + boundary); writer.println("Content-Disposition: form-data; name=\"file1\"; filename=\"" + textFile.getName() + "\""); writer.println("Content-Type: application/octet-stream"); FileInputStream fin = new FileInputStream(textFile); writer.println(); IOUtils.copy(fin, output); writer.println(); // End of multipart/form-data. writer.println("--" + boundary + "--"); output.flush(); closeQuietly(fin, writer, output); // Above request will never be sent if .getInputStream() or .getResponseCode() or .getResponseMessage() does not get called. connection.getResponseCode(); } }

    Read the article

  • How to inherit from DataAnnotations.ValidationAttribute (it appears SecureCritical under Visual Stud

    - by codetuner
    Hi, I have an [AllowPartiallyTrustedCallers] class library containing subtypes of the System.DataAnnotations.ValidationAttribute. The library is used on contract types of WCF services. In .NET 2/3.5, this worked fine. Since .NET 4.0 however, running a client of the service in the Visual Studio debugger results in the exception "Inheritance security rules violated by type: '(my subtype of ValidationAttribute)'. Derived types must either match the security accessibility of the base type or be less accessible." (System.TypeLoadException) The error appears to occure only when all of the following conditions are met: a subclass of ValidationAttribute is in an AllowPartiallyTrustedCallers assembly reflection is used to check for the attribute the Visual Studio hosting process is enabled (checkbox on Project properties, Debug tab) So basically, in Visual Studio.NET 2010: create a new Console project, add a reference to "System.ComponentModel.DataAnnotations" 4.0.0.0, write the following code: . using System; [assembly: System.Security.AllowPartiallyTrustedCallers()] namespace TestingVaidationAttributeSecurity { public class MyValidationAttribute : System.ComponentModel.DataAnnotations.ValidationAttribute { } [MyValidation] public class FooBar { } class Program { static void Main(string[] args) { Console.WriteLine("ValidationAttribute IsCritical: {0}", typeof(System.ComponentModel.DataAnnotations.ValidationAttribute).IsSecurityCritical); FooBar fb = new FooBar(); fb.GetType().GetCustomAttributes(true); Console.WriteLine("Press enter to end."); Console.ReadLine(); } } } Press F5 and you get the exception ! Press Ctrl-F5 (start without debugging), and it all works fine without exception... The strange thing is that the ValidationAttribute will or will not be securitycritical depending on the way you run the program (F5 or Ctrl+F5). As illustrated by the Console.WriteLine in the above code. But then again, this appear to happen with other attributes (and types?) too. Now the questions... Why do I have this behaviour when inheriting from ValidationAttribute, but not when inheriting from System.Attribute ? (Using Reflector I don't find special settings on the ValidationAttribute class or it's assembly) And what can I do to solve this ? How can I keep MyValidationAttribute inheriting from ValidationAttribute in an AllowPartiallyTrustedCallers assembly without marking it SecurityCritical, still using the new .NET 4 level 2 security model and still have it work using the VS.NET debug host (or other hosts) ?? Thanks a lot! Rudi

    Read the article

  • The fastest way to resize images from ASP.NET. And it’s (more) supported-ish.

    - by Bertrand Le Roy
    I’ve shown before how to resize images using GDI, which is fairly common but is explicitly unsupported because we know of very real problems that this can cause. Still, many sites still use that method because those problems are fairly rare, and because most people assume it’s the only way to get the job done. Plus, it works in medium trust. More recently, I’ve shown how you can use WPF APIs to do the same thing and get JPEG thumbnails, only 2.5 times faster than GDI (even now that GDI really ultimately uses WIC to read and write images). The boost in performance is great, but it comes at a cost, that you may or may not care about: it won’t work in medium trust. It’s also just as unsupported as the GDI option. What I want to show today is how to use the Windows Imaging Components from ASP.NET APIs directly, without going through WPF. The approach has the great advantage that it’s been tested and proven to scale very well. The WIC team tells me you should be able to call support and get answers if you hit problems. Caveats exist though. First, this is using interop, so until a signed wrapper sits in the GAC, it will require full trust. Second, the APIs have a very strong smell of native code and are definitely not .NET-friendly. And finally, the most serious problem is that older versions of Windows don’t offer MTA support for image decoding. MTA support is only available on Windows 7, Vista and Windows Server 2008. But on 2003 and XP, you’ll only get STA support. that means that the thread safety that we so badly need for server applications is not guaranteed on those operating systems. To make it work, you’d have to spin specialized threads yourself and manage the lifetime of your objects, which is outside the scope of this article. We’ll assume that we’re fine with al this and that we’re running on 7 or 2008 under full trust. Be warned that the code that follows is not simple or very readable. This is definitely not the easiest way to resize an image in .NET. Wrapping native APIs such as WIC in a managed wrapper is never easy, but fortunately we won’t have to: the WIC team already did it for us and released the results under MS-PL. The InteropServices folder, which contains the wrappers we need, is in the WicCop project but I’ve also included it in the sample that you can download from the link at the end of the article. In order to produce a thumbnail, we first have to obtain a decoding frame object that WIC can use. Like with WPF, that object will contain the command to decode a frame from the source image but won’t do the actual decoding until necessary. Getting the frame is done by reading the image bytes through a special WIC stream that you can obtain from a factory object that we’re going to reuse for lots of other tasks: var photo = File.ReadAllBytes(photoPath); var factory = (IWICComponentFactory)new WICImagingFactory(); var inputStream = factory.CreateStream(); inputStream.InitializeFromMemory(photo, (uint)photo.Length); var decoder = factory.CreateDecoderFromStream( inputStream, null, WICDecodeOptions.WICDecodeMetadataCacheOnLoad); var frame = decoder.GetFrame(0); We can read the dimensions of the frame using the following (somewhat ugly) code: uint width, height; frame.GetSize(out width, out height); This enables us to compute the dimensions of the thumbnail, as I’ve shown in previous articles. We now need to prepare the output stream for the thumbnail. WIC requires a special kind of stream, IStream (not implemented by System.IO.Stream) and doesn’t directlyunderstand .NET streams. It does provide a number of implementations but not exactly what we need here. We need to output to memory because we’ll want to persist the same bytes to the response stream and to a local file for caching. The memory-bound version of IStream requires a fixed-length buffer but we won’t know the length of the buffer before we resize. To solve that problem, I’ve built a derived class from MemoryStream that also implements IStream. The implementation is not very complicated, it just delegates the IStream methods to the base class, but it involves some native pointer manipulation. Once we have a stream, we need to build the encoder for the output format, which could be anything that WIC supports. For web thumbnails, our only reasonable options are PNG and JPEG. I explored PNG because it’s a lossless format, and because WIC does support PNG compression. That compression is not very efficient though and JPEG offers good quality with much smaller file sizes. On the web, it matters. I found the best PNG compression option (adaptive) to give files that are about twice as big as 100%-quality JPEG (an absurd setting), 4.5 times bigger than 95%-quality JPEG and 7 times larger than 85%-quality JPEG, which is more than acceptable quality. As a consequence, we’ll use JPEG. The JPEG encoder can be prepared as follows: var encoder = factory.CreateEncoder( Consts.GUID_ContainerFormatJpeg, null); encoder.Initialize(outputStream, WICBitmapEncoderCacheOption.WICBitmapEncoderNoCache); The next operation is to create the output frame: IWICBitmapFrameEncode outputFrame; var arg = new IPropertyBag2[1]; encoder.CreateNewFrame(out outputFrame, arg); Notice that we are passing in a property bag. This is where we’re going to specify our only parameter for encoding, the JPEG quality setting: var propBag = arg[0]; var propertyBagOption = new PROPBAG2[1]; propertyBagOption[0].pstrName = "ImageQuality"; propBag.Write(1, propertyBagOption, new object[] { 0.85F }); outputFrame.Initialize(propBag); We can then set the resolution for the thumbnail to be 96, something we weren’t able to do with WPF and had to hack around: outputFrame.SetResolution(96, 96); Next, we set the size of the output frame and create a scaler from the input frame and the computed dimensions of the target thumbnail: outputFrame.SetSize(thumbWidth, thumbHeight); var scaler = factory.CreateBitmapScaler(); scaler.Initialize(frame, thumbWidth, thumbHeight, WICBitmapInterpolationMode.WICBitmapInterpolationModeFant); The scaler is using the Fant method, which I think is the best looking one even if it seems a little softer than cubic (zoomed here to better show the defects): Cubic Fant Linear Nearest neighbor We can write the source image to the output frame through the scaler: outputFrame.WriteSource(scaler, new WICRect { X = 0, Y = 0, Width = (int)thumbWidth, Height = (int)thumbHeight }); And finally we commit the pipeline that we built and get the byte array for the thumbnail out of our memory stream: outputFrame.Commit(); encoder.Commit(); var outputArray = outputStream.ToArray(); outputStream.Close(); That byte array can then be sent to the output stream and to the cache file. Once we’ve gone through this exercise, it’s only natural to wonder whether it was worth the trouble. I ran this method, as well as GDI and WPF resizing over thirty twelve megapixel images for JPEG qualities between 70% and 100% and measured the file size and time to resize. Here are the results: Size of resized images   Time to resize thirty 12 megapixel images Not much to see on the size graph: sizes from WPF and WIC are equivalent, which is hardly surprising as WPF calls into WIC. There is just an anomaly for 75% for WPF that I noted in my previous article and that disappears when using WIC directly. But overall, using WPF or WIC over GDI represents a slight win in file size. The time to resize is more interesting. WPF and WIC get similar times although WIC seems to always be a little faster. Not surprising considering WPF is using WIC. The margin of error on this results is probably fairly close to the time difference. As we already knew, the time to resize does not depend on the quality level, only the size does. This means that the only decision you have to make here is size versus visual quality. This third approach to server-side image resizing on ASP.NET seems to converge on the fastest possible one. We have marginally better performance than WPF, but with some additional peace of mind that this approach is sanctioned for server-side usage by the Windows Imaging team. It still doesn’t work in medium trust. That is a problem and shows the way for future server-friendly managed wrappers around WIC. The sample code for this article can be downloaded from: http://weblogs.asp.net/blogs/bleroy/Samples/WicResize.zip The benchmark code can be found here (you’ll need to add your own images to the Images directory and then add those to the project, with content and copy if newer in the properties of the files in the solution explorer): http://weblogs.asp.net/blogs/bleroy/Samples/WicWpfGdiImageResizeBenchmark.zip WIC tools can be downloaded from: http://code.msdn.microsoft.com/wictools To conclude, here are some of the resized thumbnails at 85% fant:

    Read the article

  • Detect a white square in a black and white image

    - by gcc
    I saw that question i one web site (cite name like that programm.) then i tried to solve but icannot (not my and myfriend homework ) how can i approach to that one (in program.net no solution there is ) Read black & white image data from standard input, and detect a white square in the image. Output the coordinates of the upper left corner of the square, and the width of the square. In the preliminary work, you can print the output and terminate your program after you detect your first square. If you can't find any square on the image, you will print the string: "NO DETECTION". Input (which represents a 2 by 2 square in the center of a 5 by 4 image): 2 2 5 4 0 0 0 0 0 0 0 255 255 0 0 0 255 255 0 0 0 0 0 0 Output: 3 2 2 Input (more comprehensible format of the image, with the same output): 2 6 4 000 000 000 000 000 000 000 000 255 255 255 000 000 000 000 255 255 000 000 000 000 000 000 000 Output: no detection Input can be: 000 255 255 000 000 000 000 255 255 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 255 255 255 000 000 000 255 255 255 000 000 000 255 255 255 000 000 000 000 000 000 000 If there are two squares detected, we should use the biggest one

    Read the article

  • String search and write into file in jython

    - by kdev
    hi Everyone , i wish to write a program that can read a file and if a particular str_to_find is found in a bigger string say AACATGCCACCTGAATTGGATGGAATTCATGCGGGACACGCGGATTACACCTATGAGCAGAAATACGGCCTGCGCGATTACCGTGGCGGTGGACGTTCTTCCGCGCGTGAAACCGCGATGCGCGTAGCGGCAGGGGCGATCGCCAAGAAATACCTGGCGGAAAAGTTCGGCATCGAAATCCGCGGCTGCCTGACCCAGATGGGCGACATTCCGCTGGAGATTAAAGACTGGCGTCAGGTTGAGCTTAATCCGTTTTC then write that line and the above line of it into the file and keep repeating it for all the match found. Please suggest i have written the program for printing that particular search line but i dont know how to write the above line. Thanks everyone for your help. import re import string file=open('C:/Users/Administrator/Desktop/input.txt','r') output=open('C:/Users/Administrator/Desktop/output.txt','w') count_record=file.readline() str_to_find='AACCATGC' while count_record: if string.find(list,str_to_find) ==0: output.write(count_record) file.close() output.close()

    Read the article

< Previous Page | 149 150 151 152 153 154 155 156 157 158 159 160  | Next Page >