Search Results

Search found 5175 results on 207 pages for 'red soft adair'.

Page 153/207 | < Previous Page | 149 150 151 152 153 154 155 156 157 158 159 160  | Next Page >

  • ERROR with rpm_check_debug vs depsolve

    - by Frank Thornton
    Transaction Summary ========================================================================================================================================================== Install 9 Package(s) Upgrade 227 Package(s) Remove 1 Package(s) Total size: 252 M Downloading Packages: Running rpm_check_debug ERROR with rpm_check_debug vs depsolve: libasound.so.2()(64bit) is needed by libgcj-4.4.7-4.el6.x86_64 libasound.so.2(ALSA_0.9)(64bit) is needed by libgcj-4.4.7-4.el6.x86_64 ** Found 15 pre-existing rpmdb problem(s), 'yum check' output follows: alsa-lib-devel-1.0.22-3.el6.x86_64 has missing requires of alsa-lib = ('0', '1.0.22', '3.el6') alsa-lib-devel-1.0.22-3.el6.x86_64 has missing requires of libasound.so.2()(64bit) alsa-utils-1.0.22-5.el6.x86_64 has missing requires of libasound.so.2()(64bit) alsa-utils-1.0.22-5.el6.x86_64 has missing requires of libasound.so.2(ALSA_0.9)(64bit) alsa-utils-1.0.22-5.el6.x86_64 has missing requires of libasound.so.2(ALSA_0.9.0rc4)(64bit) alsa-utils-1.0.22-5.el6.x86_64 has missing requires of libasound.so.2(ALSA_0.9.0rc8)(64bit) frontpage-2002-SR1.2.i386 has missing requires of libexpat.so.0 gstreamer-plugins-base-0.10.29-2.el6.x86_64 has missing requires of libasound.so.2()(64bit) gstreamer-plugins-base-0.10.29-2.el6.x86_64 has missing requires of libasound.so.2(ALSA_0.9)(64bit) gstreamer-plugins-base-0.10.29-2.el6.x86_64 has missing requires of libasound.so.2(ALSA_0.9.0rc4)(64bit) libgcj-4.4.7-3.el6.x86_64 has missing requires of libasound.so.2()(64bit) libgcj-4.4.7-3.el6.x86_64 has missing requires of libasound.so.2(ALSA_0.9)(64bit) 1:qt-x11-4.6.2-26.el6_4.x86_64 has missing requires of libasound.so.2()(64bit) 1:qt-x11-4.6.2-26.el6_4.x86_64 has missing requires of libasound.so.2(ALSA_0.9)(64bit) 1:qt-x11-4.6.2-26.el6_4.x86_64 has missing requires of libasound.so.2(ALSA_0.9.0rc4)(64bit) Your transaction was saved, rerun it with: yum load-transaction /tmp/yum_save_tx-2013-12-23-22-364infzT.yumtx root@www1 [~]# I did some research and this is due to a 32bit binary trying to install itself or broken repo? root@www1 [~]# yum repolist Loaded plugins: fastestmirror, security Loading mirror speeds from cached hostfile * base: centos.mirror.lstn.net * extras: mirror.ash.fastserv.com * updates: ftp.usf.edu repo id repo name status base CentOS-6 - Base 6,284+83 dag Dag RPM Repository for Red Hat Enterprise Linux 4,559+91 extras CentOS-6 - Extras 14 updates CentOS-6 - Updates 247+39 repolist: 11,104 Now I disabled epel and rpmforge repops and still ended up with the same issues. Ideas?

    Read the article

  • Can't find standalone Chrome Gmail client that I know exists

    - by Carson
    I'm on Windows. A couple years ago when I switched from Outlook to Gmail (Google Apps), Google provided this awesome little standalone gmail client that was just a single-purpose Chrome install. It launched like a normal application, stayed updated when I updated Chrome. It was Chrome in a separate application that launched only gmail, stayed logged in really well, and "felt" like a gmail mail client, with the gmail interface. It had it's own little red envelope icon, it was a windows app. (I remember there was no Mac equivalent.) I found it while looking through the "this is how you get your company to switch to gmail" documentation that Google provided. I just repaved my box and now I'm looking for this thing again, and I had no idea it would be impossible to find. I've spent literally 2 hours looking, searching, googling, etc. I'm losing my mind. Anyone know how I can get my hands on this? I used it all day every day for 2 years, so I know it exists :), but I can not find it. Any assistance would be gratefully received.

    Read the article

  • Ubuntu 12.04 KVM running Ubuntu 12.04 with linux-image-virtual crash on boot

    - by D.Mill
    One of my VMs is stuck on "pause" in virsh. If I destroy and restart it, it will go to pause after a bit of time as "running". I can at best enter my username at login if I'm quick but it'll then shutdown. I don't know where to start with this so any help would be great!! I can access the VMs files via guestfish. the kern.log and syslog don't populate new lines. This is the last input I get from kern.log: Dec 13 11:21:08 soft201 kernel: imklog 5.8.6, log source = /proc/kmsg started. Dec 13 11:21:08 soft201 kernel: [ 0.000000] Initializing cgroup subsys cpuset Dec 13 11:21:08 soft201 kernel: [ 0.000000] Initializing cgroup subsys cpu Dec 13 11:21:08 soft201 kernel: [ 0.000000] Linux version 3.2.0-34-virtual (buildd@allspice) (gcc version 4.6.3 (Ubuntu/Linaro 4.6.3-1ubuntu5) ) #53-Ubuntu SMP Thu Nov 15 11:08:40 UTC 2012 (Ubuntu 3.2.0-34.53-virtual 3.2.33) Dec 13 11:21:08 soft201 kernel: [ 0.000000] Command line: root=UUID=61d48b48-a06a-48fb-842e-b38014086a93 ro quiet splash Dec 13 11:21:08 soft201 kernel: [ 0.000000] KERNEL supported cpus: Dec 13 11:21:08 soft201 kernel: [ 0.000000] Intel GenuineIntel Dec 13 11:21:08 soft201 kernel: [ 0.000000] AMD AuthenticAMD Dec 13 11:21:08 soft201 kernel: [ 0.000000] Centaur CentaurHauls Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-provided physical RAM map: Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-e820: 00000000000f0000 - 0000000000100000 (reserved) Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-e820: 0000000000100000 - 00000000dfffc000 (usable) Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-e820: 00000000dfffc000 - 00000000e0000000 (reserved) Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-e820: 00000000feffc000 - 00000000ff000000 (reserved) Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-e820: 00000000fffc0000 - 0000000100000000 (reserved) Dec 13 11:21:08 soft201 kernel: [ 0.000000] BIOS-e820: 0000000100000000 - 0000000a20000000 (usable) Dec 13 11:21:08 soft201 kernel: [ 0.000000] NX (Execute Disable) protection: active Dec 13 11:21:08 soft201 kernel: [ 0.000000] DMI 2.4 present. Dec 13 11:21:08 soft201 kernel: [ 0.000000] DMI: Bochs Bochs, BIOS Bochs 01/01/2007 Dec 13 11:21:08 soft201 kernel: [ 0.000000] e820 update range: 0000000000000000 - 0000000000010000 (usable) ==> (reserved) Dec 13 11:21:08 soft201 kernel: [ 0.000000] e820 remove range: 00000000000a0000 - 0000000000100000 (usable) Dec 13 As you can see the last line gets cut off. I don't even know if this is that relevant. dmesg logs are empty. The qemu log for the VM returns this: 2012-12-13 12:29:47.584+0000: starting up LC_ALL=C PATH=/usr/local/sbin:/usr/local/bin:/usr/bin:/usr/sbin:/sbin:/bin QEMU_AUDIO_DRV=none /usr/bin/kvm -S -M pc-1.0 -enable-kvm -m 40960 -smp 14,sockets=14,cores=1,threads=1 -name numerink201 -uuid f4a889ed-a089-05d0-cc9d-9825ab1faeba -nodefconfig -nodefaults -chardev socket,id=charmonitor,path=/var/lib/libvirt/qemu/numerink201.monitor,server,nowait -mon chardev=charmonitor,id=monitor,mode=control -rtc base=utc -no-shutdown -drive file=/var/lib/libvirt/images/client.soft.fr/tmpcZAD9U.qcow2,if=none,id=drive-ide0-0-0,format=qcow2 -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0,bootindex=1 -fsdev local,security_model=none,id=fsdev-fs0,path=/home/shared_folders/soft201 -device virtio-9p-pci,id=fs0,fsdev=fsdev-fs0,mount_tag=hostshare,bus=pci.0,addr=0x5 -netdev tap,fd=18,id=hostnet0 -device virtio-net-pci,netdev=hostnet0,id=net0,mac=02:00:00:1d:b9:e7,bus=pci.0,addr=0x3 -chardev pty,id=charserial0 -device isa-serial,chardev=charserial0,id=serial0 -usb -vnc 127.0.0.1:0 -vga cirrus -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x4 char device redirected to /dev/pts/3 qemu: terminating on signal 15 from pid 28248 2012-12-13 12:30:14.455+0000: shutting down I've added more logging, libvirt.log gives me this: 2012-12-13 13:24:38.525+0000: 27694: info : libvirt version: 0.9.8 2012-12-13 13:24:38.525+0000: 27694: error : virExecWithHook:328 : Cannot find 'pm-is-supported' in path: No such file or directory 2012-12-13 13:24:38.525+0000: 27694: warning : qemuCapsInit:856 : Failed to get host power management capabilities 2012-12-13 13:24:39.865+0000: 27694: error : virExecWithHook:328 : Cannot find 'pm-is-supported' in path: No such file or directory 2012-12-13 13:24:39.865+0000: 27694: warning : lxcCapsInit:77 : Failed to get host power management capabilities 2012-12-13 13:24:39.866+0000: 27694: error : virExecWithHook:328 : Cannot find 'pm-is-supported' in path: No such file or directory 2012-12-13 13:24:39.866+0000: 27694: warning : umlCapsInit:87 : Failed to get host power management capabilities I don't really know where to go from here. I'll post whatever info you require

    Read the article

  • VMware vSphere Hypervisor 5 with Intel SPL 5000 in Raid 0 no boot from DVD?

    - by Richard
    I hope this is the correct StackExchange, since I am only using StackOverflow for Web development, but need some help with my server configuration. I would like to install VMware vSphere Hypervisor 5 on my server here at home and run a view machines on it such as Windows Server 2008 and Red Hat. I used to have either OpenSuse or Windows Server 2008 installed but I would like to get into VMWare Hypervisor. My hardware configuration: - Intel S5000PSL with bios version S5000.86B.10.60.0091 build date 10/09/2008 as of read out of bios - E5420 @ 2.5GHz Intel Xeon CPU The Intel Virtualization Technology is enabled in the BIOS - DVD DH20A4P DVD Writer - 8GB ECC Ram I have configured a RAID 0 on my 2 WD 2TB SATA drives I have burned the Hypervisor 5 on an empty DVD and it is bootable, I tested it on my client PC. The main problem here is basically, that I cannot boot the DVD on my server. I have set the Boot Option to the DVD drive. I have booted from the BIOS straight in the DVD drive and it does not work. I do not see any error messages. The only thing I see are the PXE error messages when it tries booting from the network and other devices, obviously without any result. Does anybody know why I cannot boot the DVD? What could cause the problem? I have sucessfully installed Windows Server 2008 via original DVD about 1 year ago, so the DVD drive can read and does work. The DVD drive is available in the BIOS and I have checked all cables and none of them is loose in any way. I even see the light flashing but it does not want to boot from the DVD. I am looking forward to suggestions and things that I should check. Thank you very much

    Read the article

  • mcelog doesn't fails to start PUIAS 6.4 amd hardware

    - by Predrag Punosevac
    Folks, I am a total Linux n00b. I am trying to deploy mcelog on one of my computing nodes running PUIAS 6.4 (i86_64) [root@lov3 edac]# uname -a Linux lov3.mylab.org 2.6.32-358.18.1.el6.x86_64 #1 SMP Tue Aug 27 22:40:32 EDT 2013 x86_64 x86_64 x86_64 GNU/Linux a free clone of Red Hat 6.4 on AMD hardware [root@lov3 mcelog]# lscpu Architecture: x86_64 CPU op-mode(s): 32-bit, 64-bit Byte Order: Little Endian CPU(s): 64 On-line CPU(s) list: 0-63 Thread(s) per core: 2 Core(s) per socket: 8 Socket(s): 4 NUMA node(s): 8 Vendor ID: AuthenticAMD CPU family: 21 Model: 2 Stepping: 0 CPU MHz: 1400.000 BogoMIPS: 4999.30 Virtualization: AMD-V L1d cache: 16K L1i cache: 64K L2 cache: 2048K L3 cache: 6144K NUMA node0 CPU(s): 0-7 NUMA node1 CPU(s): 8-15 NUMA node2 CPU(s): 16-23 NUMA node3 CPU(s): 24-31 NUMA node4 CPU(s): 32-39 NUMA node5 CPU(s): 40-47 NUMA node6 CPU(s): 48-55 NUMA node7 CPU(s): 56-63 My mcelog.conf file is more or less default apart of the fact that I would like to run mcelog as a daemon and to log errors. When I start mcelog [root@lov3 mcelog]# mcelog --config-file mcelog.conf AMD Processor family 21: Please load edac_mce_amd module. However the module is present [root@lov3 mcelog]# locate edac_mce_amd.ko /lib/modules/2.6.32-358.18.1.el6.x86_64/kernel/drivers/edac/edac_mce_amd.ko /lib/modules/2.6.32-358.el6.x86_64/kernel/drivers/edac/edac_mce_amd.ko and loaded [root@lov3 edac]# lsmod | grep mce edac_mce_amd 14705 1 amd64_edac_mod Is there anything that I can do to get mcelog working? The only reference I found is this thread http://lists.centos.org/pipermail/centos/2012-November/130226.html

    Read the article

  • Adding PHP to Apache

    - by user528451
    Where I work, we use ancient technology that belongs in a museum. Further I have to get everything done through system admins. They are telling me in order to get PHP, they will need to upgrade the operating system as well as the Apache version. lcas100[67]% uname -a Linux lcas100 2.6.9-11.ELsmp #1 SMP Fri May 20 18:26:27 EDT 2005 i686 i686 i386 GNU/Linux lcas100[68]% cat /etc/*-release LSB_VERSION="1.3" Red Hat Enterprise Linux AS release 4 (Nahant) lcas100[75]% /ots/apache/bin/httpd -v Server version: Apache/1.3.31 (Unix) Server built: Nov 3 2004 18:47:31 This doesn't make sense to me because apparently Apache 1.3.x supports PHP: http://php.net/manual/en/install.unix.apache.php Furthermore, we have another machine that runs PHP and is running the exact same OS and OS version. The reason I want it on the former machine is because it is mounted on a different file system. Lastly they tell me that all software the Apache webserver runs will need to be reinstalled/recompiled (assuming an Apache upgrade WAS needed). I am not even sure about this. Are they full of it? Thanks

    Read the article

  • Recompiling Nginx 1.4.3 with "--with-http_gzip_static_module" error

    - by Elijah Paul
    I'm trying to enable the 'ngx_http_gzip_static_module' module in Nginx 1.4.3 by adding the --with-http_gzip_static_module to my ./configure configuration. But I recieve the following error when i try to recompile (make): # make make -f objs/Makefile make[1]: Entering directory `/tmp/nginx-1.4.3' make[1]: *** No rule to make target `src/os/unix/ngx_gcc_atomic_x86.h', needed by `objs/src/core/nginx.o'. Stop. make[1]: Leaving directory `/tmp/nginx-1.4.3' make: *** [build] Error 2 My current config (CentOS 6.4): # nginx -V nginx version: nginx/1.4.3 built by gcc 4.4.7 20120313 (Red Hat 4.4.7-3) (GCC) TLS SNI support enabled configure arguments: --conf-path=/etc/nginx/nginx.conf --pid-path=/var/run/nginx.pid --error-log-path=/var/log/nginx/error.log --http-proxy-temp-path=/var/cache/nginx/proxy_temp --http-fastcgi-temp-path=/var/cache/nginx/fastcgi_temp --http-uwsgi-temp-path=/var/cache/nginx/uwsgi_temp --http-scgi-temp-path=/var/cache/nginx/scgi_temp --http-log-path=/var/log/nginx/access.log --with-http_ssl_module --prefix=/usr --add-module=./nginx-sticky-module-1.1 --add-module=./headers-more-nginx-module-0.23 i was under the impression that this was a module that just need to be 'enabled' as opposed to 'added'. What am I missing here?

    Read the article

  • Windows Media Player 12 Library import keeps dying

    - by duckworth
    I cannot get WMP 12 to import my library. I have searched around various forums and tried all the common solutions like disabling Media Sharing, deleted my %LOCALAPPDATA%\Microsoft\Media Player directory and tried reimporting, etc. but nothing works. I have even removed the Media features from Windows setup and re-added them. I have a large mp3 collection shared on the network from another Windows box. I add the folder (tried as a mapped drive and UNC path) and it begins importing. After about 30 minutes into the import (the CurrentDatabase_372.wmdb hits just under 400MB) my WMP player stops importing and all of the icons in WMP turn to red x's and my library is gone. I close and reopen WMP 12 and the library is empty and the CurrentDatabase_372.wmdb is small and it strarts importing again. Rinse, lather, repeat. I am going nuts as WMP11 on Vista handles this same setup perfectly. I am at my wits end on what else to try. I am running a legit Windows 7 Ultimate X64 RTM install. Here is a screenshot of what WMP12 looks like when the import dies: Any other ideas? Edit: OK, I Just confirmed this is definitely a problem not specific to my computer or configuration. I just did a clean installation of Windows 7 Ultimate x86 on an old test machine, opened WMP12 and added the same network folder of mp3's and it crashed about an hour into the import with the same appearance as the screenshot I posted above and the library disappears. So the problem has to be one of several things: The large size of the library The fact that the library is on the network A specific file or file is causing it the player to crash

    Read the article

  • The email address used to help trust my PC, is no longer valid, how do I fix that?

    - by Rod
    A few nights ago I upgraded my Windows 7 PC to Windows 8. This morning, when I logged into my PC, I noticed the little flag in the system tray, in desktop mode, had a red "X" on it. I checked it and one of the issues was my needing to tell Windows 8 that I trusted my PC. I clicked on the link to trust my PC, and saw the button to tell it to trust my PC, and so I did. After doing that it send it had sent out an email to a really old email address I had, which hasn't been valid for many years. Now what? Will that "trusting my PC" be invalid, because I can't respond to it (which certainly isn't true, if it's sending messages to so old email address). I didn't even know that Windows still had such an old email address. I'm concerned that I won't have a trust relationship with my own PC, that somehow or other whatever holds onto my information has old information and that I am not sure how to change it in as fast a manner as possible so that I can trust my own PC. How do I do these things?

    Read the article

  • Cannot print certain colours on Ubuntu with HP Laser Printer

    - by ILMV
    We have a load of machines running Ubuntu in our office, they are either on 8.04 or 9.10. We have a server which connects a HP JetDirect that connects to a HP 3550 Colour Laser printer using CUPS. The problem we are having is we cannot print red, magenta or yellow at 100%, I've got a picture of the Ubuntu test page to demonstrate my problem: This is obviously a pretty big problem as we are constantly receiving documents with these colours and cannot successfully print them off, we cannot just switch the grayscale, our business depends on being able to print colour (seems trivial but we handle lots of artwork). We're using the recommended driver HP Color LaserJet 3550 footmatic/pxljr (recommended), there is another driver in the list labelled HP Color LaserJet 3550 footmatic/hpijs. These are production printers so need to make sure any setting change won't kick is in the nuts. It would appear HPIJS is for HP Inkjets, makes sense I guess. The problem doesn't occur in Windows. RESOLVED I've managed to solve the problem, I did indeed use the HPIJS driver (apparently for inkjets) but it seems to have worked, we're going to roll with it for now to see how we get on with it.

    Read the article

  • Startup script for Red5 on Ubuntu 9.04

    - by user49249
    I am creating startup script for Red5 on Ubuntu. Red5 is installed in /opt/red5 Following is a working script on a CentOS Box on which Red5 is running [code] ==========Start init script ========== #!/bin/sh PROG=red5 RED5_HOME=/opt/red5/dist DAEMON=$RED5_HOME/$PROG.sh PIDFILE=/var/run/$PROG.pid # Source function library . /etc/rc.d/init.d/functions [ -r /etc/sysconfig/red5 ] && . /etc/sysconfig/red5 RETVAL=0 case "$1" in start) echo -n $"Starting $PROG: " cd $RED5_HOME $DAEMON >/dev/null 2>/dev/null & RETVAL=$? if [ $RETVAL -eq 0 ]; then echo $! > $PIDFILE touch /var/lock/subsys/$PROG fi [ $RETVAL -eq 0 ] && success $"$PROG startup" || failure $"$PROG startup" echo ;; stop) echo -n $"Shutting down $PROG: " killproc -p $PIDFILE RETVAL=$? echo [ $RETVAL -eq 0 ] && rm -f /var/lock/subsys/$PROG ;; restart) $0 stop $0 start ;; status) status $PROG -p $PIDFILE RETVAL=$? ;; *) echo $"Usage: $0 {start|stop|restart|status}" RETVAL=1 esac exit $RETVAL [/code] What do I need to replace for Ubuntu in the above script. My Red5 is in /opt/red5/ and to start it manually I always do /opt/red5/dist/red5.sh from Ubuntu As I did not find rc.d/functions on Ubuntu on my laptop also /etc/init.d/functions I did not existed. I would like to be able to use them with service as Red hat distributions do. I checked /lib/lsb/init-functions.

    Read the article

  • Xen guests accessing LUNs

    - by mechcow
    We are using RHEL5.3 with a Clarion SAN attached by FC. Our situation is that we have a number of LUNs presented to Hosts and we want to dynamically present the LUNs to Xen Guests. We are not sure on what the best practice approach is to set this up. The Xen guests will form a cluster together and need the LUNs only for data partitions, i.e. when they are actively running services. So one approach would be to always present all disks to all Xen guests, and then rely up on the cluster software, and mount itself, to not mount the disk twice in two locations. This sounds kinda risky and also is not very secure (one cracked guest can see/destroy all the data). Another approach would be to dynamically add and remove the disks from the Xen guests at the dom0 level (using xm block-attach). This could work but sounds slightly complicated, I'm wondering whether Red Hat Cluster Suite supports this in some way or whether there are scripts to do this. Yet another approach would be to have the LUNs endpointed at the Xen guests themselves - I'm not sure whether this is technically possible since the multipathing has to be done at the Host level.

    Read the article

  • "Learning" Linux

    - by Strider
    I've been interested in computers for a long time and have fiddled with a lot of stuff which includes Linux. I started out with Red Hat when I was young (around 13) and lost all data, converting a FAT32 drive to something else. Later it was Knoppix which was really helpful in recovery and such. Then, it was Ubuntu. Also, I fiddled with Arch for some time, but, it breaks too often for my liking (maybe, I should have been more careful). Anyway, currently I use Ubuntu 9.04. I want to dig deeper into the Linux world now. I want to learn how things work and use the terminal more. I am a programmer as well, so, it will help a lot. So, the thing I wanted to ask were: Good books to learn and understand Linux Good habits to use Linux more efficiently. Good tools about which I should know. Amount of time you set aside to learn about new things each day. As a programmer, how do you setup and use Linux efficiently. Long list. I will be grateful to the answerers.

    Read the article

  • Fast Ethernet module for Cisco 2620

    - by Kenny Rasschaert
    I have a Cisco 2620 Router. It comes with one fast ethernet port built in (circled in red), and one old AUI ethernet module is installed (circled in blue). I figure I can put a transceiver on the AUI interface to get a second RJ45 connector. What I'd really like to have is a second fast ethernet connector. The ideal candidate to achieve this would be the NM-1FE-TX module. Cisco claims on their website that this module is not suitable for the Cisco 2620 and Cisco 2620XM. It says so in "Table 2 Physical Limitation of Serial Modules per Chassis". Indeed, this module was designed for the 3600 series of routers. I've seen claims on the internet, however, of people having this module on a 2620XM, and it being fully functional. This claim gains some credibility because of the fact that in Cisco's own Packet Tracer software, you can install this module on the 2620XM router. I'm looking for a definitive answer. Will this module work on a Cisco 2620? Is there perhaps another way to get a second fast ethernet port on this device?

    Read the article

  • SYS-5016T-MTFB will not POST without manual assistance (Motherboard: X8STi-F)

    - by Dan
    I have a Supermicro 5016T-MTFB 1U server which I am in the process of setting up, but it has a really strange problem. When the system is powered on it will not POST until I press the reset button a few times, followed by pressing the delete key on the keyboard to "wake it up". If I power it on and do nothing, the fans spin up but nothing else happens at all. After pressing the reset button once, the red "overheat" light comes on and blinks which is supposed to indicate a fan failure - but all the fans are working. Pressing reset again usually stops the blinking, and the system starts the normal POST routine but it will not actually get to the bios screen unless I press delete. If I don't press delete, it just continues to hang. After pressing delete it will take me into the bios setup screen, if I exit without saving changes I can boot the system normally. I was able to successfully install Linux with no trouble...but upon rebooting the same problem happened again. This board has integrated IPMI which I thought was the problem, so I disabled it via the jumper on the board. Did not help. Each time this system powers on, it goes on for a second, then turns off again for another second, then turns back on again. I don't know why it does that. Here is what I put in the system: 1 x Xeon E5630 (Nehalem) 80W TDP (it's not overheating, CPU temps stay under 40 degrees C) 2 x Kingston 2GB x 3 DDR3-1066 Memory ECC, unbuffered, unregistered (kvr1066d3e7sk3/6g) 1 x Intel X25-M 160 GB 2 x Western Digital RE3 1TB

    Read the article

  • Problems with image/file upload in MediaWiki on Windows 2008 Server R2, using wrong temp directory

    - by Lasse V. Karlsen
    I have installed MediaWiki 1.15.2 under IIS as per the MediaWiki installation instructions for Windows 2008 Server. I have configured PHP to use a specific temp directory: upload_tmp_dir="C:\php\uploadtemp" I have specified that MediaWiki is allowed to upload: $wgEnableUploads = true; But when I try to upload an image, I get this error message in my browser: Internal error Could not find file "C:\Windows\Temp\php1AEA.tmp". Retrying will simply give me a new filename, but in the same location. The directory does not have any php* files in it, but since they're "temporary", they might be gone in a flash before Windows Explorer is able to show them so that might be a red herring. I've googled for this, and the most promising lead I found was on this page: Image upload problem - Is this bug fixed?, but since the text says "a bugfix was posted on the bug-report page", but provides no link to which bug page this relates to (php or mediawiki) nor the actual bug report, I've not found conclusively the bug report in question so that didn't help me much. Lots of pages indicates that this is a permission issue, so I tried setting permissions on c:\windows\temp as Modify by Everyone, still no dice. I tried changing the two system environment variables TEMP and TMP to point to C:\Temp instead, but MediaWiki still complains about not finding the file in C:\Windows\Temp. Note that I don't care a lot about where the files will actually be stored temporarily, so c:\windows\temp is fine by me. I do, however, care about them actually being uploaded correctly. Does anyone know of a fix, have any leads I can follow, or whatnot? The server is running Windows 2008 Server R2, all patches installed, and the PHP installed is 5.3.2, using IIS FastCGI.

    Read the article

  • Looking for a short term solution to improve website performance with additional server

    - by Tanim Mirza
    I am working with a small team to run an internal website running with PHP 5.3.9, MySQL 5.0.77. All the files and database are hosted on a dedicated Linux machine with the following configuration: Intel Xeon E5450 8 CPU cores @3.00GHz, 2992.498 MHz, Cache 6148 KB, Cent OS – Red Hat Enterprise Linux Server release 5.4 We started small and then the database got bigger and now the website performance degraded significantly. We often get server space overrun, mysql overloaded with too many calls, etc. We don't have much experience dealing with these issues. We recently got another server that we were thinking to use to improve performance. Since it has better configuration, some of us wanted to completely move everything to the new machine. But I am trying to find out how we can utilize both machine for optimized performance. I found options such as MySQL clustering, Load balancer, etc. I was wondering if I could get any suggestion for this situation "How to utilize two machines in short term for best performance", that would be great. By short term we are looking for something that we can deploy in a month or so. Thanks in advance for your time.

    Read the article

  • Intermittent 404 on select assets, LAMP stack

    - by Tom Lagier
    We have a LAMP stack WordPress server that is serving most assets correctly. However, one plugin's CSS file and several images are returning soft 404s roughly 20% of the time. I can't find any reference to the 404 in the access logs, but the browser is definitely receiving a 404 response from somewhere (WordPress, I would assume). When I use an alias URL that does not match the site URL but does resolve to the asset path, the resource loads correctly 100% of the time. However, using the site url only resolves for the select, problematic assets 20% of the time. You can test one of the problematic assets here: http://www.mreco.org/wp-content/uploads/2014/05/zero-cost.jpg However the alias link always resolves correctly: http://mr-eco.wordpress.promocampaigns.com/wp-content/uploads/2014/05/zero-cost.jpg Stranger, if I attempt to access outdated content that definitely does not exist on the server, at the live URL it returns the content roughly 50% of the time. Using the alias link, it 404s 100% of the time - the correct behavior. Error log and PHP error log are clean. A sample access log (pulled from grep 'zero-cost.jpg' /var/log/httpd/mr-eco-access_log) from several refreshes of the live direct link (where I am not seeing any 404's): 10.166.202.202 - - [28/May/2014:20:27:41 +0000] "GET /wp-content/uploads/2014/05/zero-cost.jpg HTTP/1.1" 304 - 10.166.202.202 - - [28/May/2014:20:27:42 +0000] "GET /wp-content/uploads/2014/05/zero-cost.jpg HTTP/1.1" 304 - 10.166.202.202 - - [28/May/2014:20:27:43 +0000] "GET /wp-content/uploads/2014/05/zero-cost.jpg HTTP/1.1" 304 - 10.166.202.202 - - [28/May/2014:20:27:43 +0000] "GET /wp-content/uploads/2014/05/zero-cost.jpg HTTP/1.1" 304 - 10.176.201.37 - - [28/May/2014:20:27:56 +0000] "GET /wp-content/uploads/2014/05/zero-cost.jpg HTTP/1.1" 200 57027 Chrome's dev tools list the following network activity before displaying 404 page content: zero-cost.jpg /wp-content/uploads/2014/05 GET 404 Not Found text/html Other 15.9?KB 73.2?KB 953?ms 947?ms My Apache configuration is standard, I've listed the virtual host entry and .htaccess file below. I can provide other parts of Apache config if necessary. Virtual host: <VirtualHost *:80> DocumentRoot /var/www/public_html/mr-eco.wordpress.promocampaigns.com ServerName www.mreco.org ServerAlias mreco.org mr-eco.wordpress.promocampaigns.com ErrorLog logs/mr-eco-error_log CustomLog logs/mr-eco-access_log common <Directory /var/www/public_html/mr-eco.wordpress.promocampaigns.com> AllowOverride All SetOutputFilter DEFLATE </Directory> </VirtualHost> .htaccess: # BEGIN WordPress <IfModule mod_rewrite.c> RewriteEngine On RewriteBase / RewriteRule ^index\.php$ - [L] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /index.php [L] </IfModule> # END WordPress I have checked for multiple A records and can confirm that there is a single A record pointing at the domain: ;; ANSWER SECTION: mreco.org. 60 IN A 50.18.58.174 I'm fairly new to systems administration, and at a complete loss as to what could cause this. In the past, inconsistently 404ing assets have been because of out-of-sync instances behind a load balancer. In this case, it is a single instance behind the load balancer. Because of the inconsistency, it feels like a caching issue. We don't make use of Apache caching, and as far as I know WordPress should not be caching either. What I've done so far: Reset WordPress permalinks Disabled WordPress plugins Re-generated WordPress .htaccess file Swapped ServerName and ServerAlias directives Cleared browser cache Confirmed disk location of resources Checked PHP, access, and error logs Confirmed correct DNS setup (can post if necessary) I'm at a total loss. Thanks for helping me out!

    Read the article

  • How to stop/kill a virtual machine that hangs in "Stopping" state?

    - by SvetP
    Hi, I have a virtual machine that constantly hangs in the “Stopping” state. I’ve red several posts suggesting killing the vmwp.exe process of the machine but I’ve never been able to kill this process neither from the Windows Task Manager nor from an administrative command prompt by using prockill /PID xxxx /F where xxxx was the process ID. The only result that I have is that my machine enters in “Stopping-Critical” state. Even worse, from that point (having a virtual machine hung at stopping) I am unable to manage (stop or start) any other virtual machine on the same host. The only “solution” in that case for me is to stop the Virtual Machine Management Service (vmms.exe) and to restart the physical host. Without first stopping the vmms.exe service my physical host also hangs during the restart. Moreover, there is no any error logged in the Event Viewer. I’ve found some other posts complaining about them problem. On all of them the only suggestion was to kill the vmwp.exe process, which obviously doesn’t work for them too. Can somebody help us with this, pls? Thanks

    Read the article

  • corrupted, hidden, wireless network adapter from "Network Connections" in Windows 7

    - by srihari reddy
    The issue is that when I install a wireless network adapter on my Windows 7 Professional machine I have no connectivity, the system tray icon has a red X. First, I tried the obvious, install updated drivers from the manufacturer. When I did this, the Network Connections icon had gray bars and there was no connectivity. So I tried installling the network adapter on a different computer on the same network and I verified that it does work with no issues. Next, I ran scan disk with no issues. Next, I ran sfc as admin with no issues. At this point I turned to the router and turned SSID broadcast on but that didn't help. I turned MAC address filtering off at the router but that didn't help. Whenever I installed the original network adapter (a wireless N usb adapter with WPA2 TKIP+AES) it showed up as "Wireless Network Connection 2" with a grayed out icon and no connectivity. Lastly, I tried installing two different "verified working" usb wireless adapters on to the Windows 7 Pro machine. The results were the same "Wireless Network Connection 2" that had a green bar icon but no connectivity. I installed the manufacturers software and it indicated the NIC was not there even thought the driver installed successfully in Device Manager. I guess I should mention, I first tried (insanely in vain) to use the (worthless) Windows Network troubleshooter. The results were....drumroll please... There is a problem with the network adapter... well No Duh! Also, during all of this the network adapter is always showing as "Working Properly" in the properties dialogue of Device Manager for the wireless NIC. I checked for hidden devices in Device Manager but there were none. Here is my fundamental question that I've tried to find in the Windows 7 support center with no luck. How do I remove/delete/uninstall network adapters from the Windows 7 registry? in particular hidden, corrupted network adapters, that used to be working.

    Read the article

  • Is Apache 2.2.22 able to sustain 1.000 simultaneous connected clients?

    - by Fnux
    For an article in a news paper, I'm benchmarking 5 different web servers (Apache2, Cherokee, Lighttpd, Monkey and Nginx). The tests made consist of measuring the execution times as well as different parameters such as the number of request served per second, the amount of RAM, the CPU used, during a growing load of simultaneous clients (from 1 to 1.000 with a step of 10) each client sending 1.000.000 requets of a small fixed file, then of a medium fixed file, then a small dynamic content (hello.php) and finally a complex dynamic content (the computation of the reimbursment of a loan). All the web servers are able to sustain such a load (up to 1.000 clients) but Apache2 which always stops to respond when the test reach 450 to 500 simultaneous clients. My configuration is : CPU: AMD FX 8150 8 cores @ 4.2 GHz RAM: 32 Gb. SSD: 2 x Crucial 240 Gb SATA6 OS: Ubuntu 12.04.3 64 bit WS: Apache 2.2.22 My Apache2 configuration is as follows: /etc/apache2/apache2.conf LockFile ${APACHE_LOCK_DIR}/accept.lock PidFile ${APACHE_PID_FILE} Timeout 30 KeepAlive On MaxKeepAliveRequests 1000000 KeepAliveTimeout 2 ServerName "fnux.net" <IfModule mpm_prefork_module> StartServers 16 MinSpareServers 16 MaxSpareServers 16 ServerLimit 2048 MaxClients 1024 MaxRequestsPerChild 0 </IfModule> User ${APACHE_RUN_USER} Group ${APACHE_RUN_GROUP} AccessFileName .htaccess <Files ~ "^\.ht"> Order allow,deny Deny from all Satisfy all </Files> DefaultType None HostnameLookups Off ErrorLog ${APACHE_LOG_DIR}/error.log LogLevel emerg Include mods-enabled/*.load Include mods-enabled/*.conf Include httpd.conf Include ports.conf LogFormat "%v:%p %h %l %u %t \"%r\" %>s %O \"%{Referer}i\" \"%{User-Agent}i\"" vhost_combined LogFormat "%h %l %u %t \"%r\" %>s %O \"%{Referer}i\" \"%{User-Agent}i\"" combined LogFormat "%h %l %u %t \"%r\" %>s %O" common LogFormat "%{Referer}i -> %U" referer LogFormat "%{User-agent}i" agent Include conf.d/ Include sites-enabled/ /etc/apache2/ports.conf NameVirtualHost *:8180 Listen 8180 <IfModule mod_ssl.c> Listen 443 </IfModule> <IfModule mod_gnutls.c> Listen 443 </IfModule> /etc/apache2/mods-available <IfModule mod_fastcgi.c> AddHandler php5-fcgi .php Action php5-fcgi /cgi-bin/php5.external <Location "/cgi-bin/php5.external"> Order Deny,Allow Deny from All Allow from env=REDIRECT_STATUS </Location> </IfModule> /etc/apache2/sites-available/default <VirtualHost *:8180> ServerAdmin webmaster@localhost DocumentRoot /var/www/apache2 <Directory /> Options FollowSymLinks AllowOverride None </Directory> <Directory /var/www/> Options Indexes FollowSymLinks MultiViews AllowOverride None Order allow,deny allow from all </Directory> ScriptAlias /cgi-bin/ /usr/lib/cgi-bin/ <Directory "/usr/lib/cgi-bin"> AllowOverride None Options +ExecCGI -MultiViews +SymLinksIfOwnerMatch Order allow,deny Allow from all </Directory> ErrorLog ${APACHE_LOG_DIR}/error.log LogLevel emerg ##### CustomLog ${APACHE_LOG_DIR}/access.log combined Alias /doc/ "/usr/share/doc/" <Directory "/usr/share/doc/"> Options Indexes MultiViews FollowSymLinks AllowOverride None Order deny,allow Deny from all Allow from 127.0.0.0/255.0.0.0 ::1/128 </Directory> <IfModule mod_fastcgi.c> AddHandler php5-fcgi .php Action php5-fcgi /php5-fcgi Alias /php5-fcgi /usr/lib/cgi-bin/php5-fcgi FastCgiExternalServer /usr/lib/cgi-bin/php5-fcgi -host 127.0.0.1:9000 -pass-header Authorization </IfModule> </VirtualHost> /etc/security/limits.conf * soft nofile 1000000 * hard nofile 1000000 So, I would trully appreciate your advice to setup Apache2 to make it able to sustain 1.000 simultaneous clients, if this is even possible. TIA for your help. Cheers.

    Read the article

  • Replacing stock Core 2 Duo heatsink fan (just the fan really) with a Dell CPU fan

    - by user647345
    My old heatsink fan broke and I'm trying to reconnect its plugs to a new fan. My Dell CPU fan has some custom Dell plug. I snipped the old fan's wire in half and kept the plug on the end of it. I want to connect it to the Dell fan wire to the plug. The motherboard is a P5Q-e, the stock Core 2 Duo fan was .20A and the dell is .70A. Is that going to matter? The wire from the fan has four wires, the wire with the plug has four wires. They share three, of the four colors: red, black, and blue. Dell's fourth wire is white, while the plug's fourth wire is yellow. Is it safe to assume that I just connect the yellow and the white plug together and match the rest up? I don't want to take any risk of damaging anything. It runs fine passively without a fan, but I have speedstep on, so I would like to use this fan and just fasten it to the heatsink with some twist ties and paperclips and call it a day.

    Read the article

  • How to extract terms from an HTML document

    - by bookcasey
    I have a HTML document filled with terms that I need to put into a spreadsheet. They follow this basic pattern: <ul> <li class="name"><a href="spot.html">Spot</a></li> <li class="type">Dog</li> <li class="color">Red</li> </ul> <ul> <li class="name"><a href="mittens.html">Mittens</a></li> <li class="type">Cat</li> <li class="color">Brown</li> </ul> <ul> <li class="name"><a href="squakers.html">Squakers</a></li> <li class="type">Little Parrot</li> <li class="color">Rainbow</li> </ul> It's very consistent. I need to extract the string within the li.name a (so, "Spot") but only if the type is "Dog" or "Parrot", and put them in a spreadsheet. I've been trying to use Sublime Text's ability to Find with regex, but I'm really struggling, and since regex and HTML usually don't play nice, I was wondering if there is a better and easier way to accomplish this. Thanks.

    Read the article

  • /usr/bin/python (Python 2.4) was deleted on CentOS 5. I compiled from source but yum is still broken. How can I get everything back to the way it was?

    - by Maxwell
    I saw a lot of other questions like this but none of them answered the exact part I am having trouble with (actually installing the Python RPM). Someone on my system deleted /usr/bin/python and /usr/bin/python2.4 on my 64 bit CentOS 5.8 installation. I recompiled Python 2.4 from source, but now whenever I try to yum install anything I get the following error: [root@cerulean-OW1 ~]# yum install httpd There was a problem importing one of the Python modules required to run yum. The error leading to this problem was: No module named yum Please install a package which provides this module, or verify that the module is installed correctly. It's possible that the above module doesn't match the current version of Python, which is: 2.4 (#1, Dec 16 2012, 09:16:56) [GCC 4.1.2 20080704 (Red Hat 4.1.2-52)] If you cannot solve this problem yourself, please go to the yum faq at: http://wiki.linux.duke.edu/YumFaq I checked http://wiki.linux.duke.edu/YumFaq and it said the following: If you are getting a message that yum itself is the missing module then you probably installed it incorreclty (or installed the source rpm using make/make install). If possible, find a prebuilt rpm that will work for your system like one from Fedora or CentOS. Or, you can download the srpm and do a rpmbuild --rebuild yum*.src.rpm I tried going to http://rpm.pbone.net/index.php3/stat/4/idpl/17838875/dir/centos_5/com/python-2.4.3-46.el5.x86_64.rpm.html to install Python, which resulted in the following error: [root@cerulean-OW1 ~]# rpm -Uvh python-2.4.3-46.el5.x86_64.rpm error: Failed dependencies: python-libs-x86_64 = 2.4.3-46.el5 is needed by python-2.4.3-46.el5.x86_64 So I tried installing python-libs-x86_64, which resulted in the following: [root@cerulean-OW1 ~]# rpm -Uvh python-libs-2.4.3-46.el5_8.2.x86_64.rpm warning: python-libs-2.4.3-46.el5_8.2.x86_64.rpm: Header V3 DSA signature: NOKEY, key ID 192a7d7d Preparing... ########################################### [100%] package python-libs-2.4.3-46.el5_8.2.x86_64 is already installed file /usr/lib64/libpython2.4.so.1.0 from install of python-libs-2.4.3-46.el5_8.2.x86_64 conflicts with file from package python-libs-2.4.3-46.el5_8.2.x86_64

    Read the article

  • Using secure proxies with Google Chrome

    - by cYrus
    Whenever I use a secure proxy with Google Chrome I get ERR_PROXY_CERTIFICATE_INVALID, I tried a lot of different scenarios and versions. The certificate I'm using a self-signed certificate: openssl genrsa -out key.pem 1024 openssl req -new -key key.pem -out request.pem openssl x509 -req -days 30 -in request.pem -signkey key.pem -out certificate.pem Note: this certificate works (with a warning since it's self-signed) when I try to setup a simple HTTPS server. The proxy Then I start a secure proxy on localhost:8080. There are a several ways to accomplish this, I tried: a custom Node.js script; stunnel; node-spdyproxy (OK, this involves SPDY too, but later... the problem is the same); [...] The browser Then I run Google Chrome with: google-chrome --proxy-server=https://localhost:8080 http://superuser.com to load, say, http://superuser.com. The issue All I get is: Error 136 (net::ERR_PROXY_CERTIFICATE_INVALID): Unknown error. in the window, and something like: [13633:13639:1017/182333:ERROR:cert_verify_proc_nss.cc(790)] CERT_PKIXVerifyCert for localhost failed err=-8179 in the console. Note: this is not the big red warning that complains about insecure certificates. Now, I have to admit that I'm quite n00b for what concerns certificates and such, if I'm missing some fundamental points, please let me know.

    Read the article

< Previous Page | 149 150 151 152 153 154 155 156 157 158 159 160  | Next Page >