Search Results

Search found 12681 results on 508 pages for 'logical drive'.

Page 156/508 | < Previous Page | 152 153 154 155 156 157 158 159 160 161 162 163  | Next Page >

  • Why Ubuntu is not booting anymore from USB live?

    - by xRobot
    I have just purchased a brand new laptop Samsung 300e5c with Windows 7. So I have reduce the windows partition and I have installed ubuntu 12.04 from my USB pen drive. Then I have tried to boot again from USB pen drive but it doesn't work anymore. I have tryed to boot on others laptop from my USB pen drive and it does work perfectly. but on my laptop, NO :(. I have set all USB drive as first boot device in BIOS. I have tryed on each USB port of my laptop but it doesn't work. Only the first time it did work when I installed ubuntu and now it doesn't work anymore. It's very strange I can see the content of the usb pen drive on my laptop and on others laptop without problems. why it doesn't work anymore ?

    Read the article

  • Windows 7/Ubuntu 12 dual boot deleted for Windows 8 installation. How to make grub rescue go away?

    - by dimious
    I had a Windows 7/Ubuntu 12 dual boot and I decided to clean install Windows 8 over them. The problem is that after I deleted all partitions and installed windows I was getting an "Operation system not found", however after an "enter" the system will normally boot into Windows 8. I realized that Windows did their trick and put the system (not partition anymore?!?) "tag" (Disk Management) on my media hard drive. After trying to fix the boot/mbr to be able to boot from my main drive the "Operation system not found" changed to the "grub rescue" prompt. I know that I cannot use that because I have killed the grub files. Windows can still boot as long as I choose to boot from the media drive. The question is, is there any way to move the "system", whatever it is now, to the main drive and have the PC boot from there, while making grub disappear? And if that is possible after that, can I just make the Media drive inactive or I will have to somehow remove the "system" tag?

    Read the article

  • How to script a reinstall (apt repo's and installed packages)

    - by Kurtosis
    I need to wipe my hard drive and reinstall Ubuntu. /home is on a separate partition, so I can back that up to a backup drive, then copy it back to the wiped drive, install ubuntu, and point it at the existing /home, no problem. However, I also want to script a reinstall of all my apt repo's and the packages I currently have installed, so I don't have to waste hours doing that manually. Anyone know a good way to do this? PS - At least, I'm pretty sure I have to wipe the drive. Need to install Windows 7, and only have an HP system restore disk that formats the whole drive, and not a legit Windows 7 install disk that lets me install on a single partition. If somebody know a way to trick the system restore disk to install only to a single partition, I'd love to hear it.

    Read the article

  • Apt Configuration problem

    - by Paul
    I am trying to load v11.04 onto my HP desktop hard drive using a USB drive. I used the same USB drive to load the system on my Dell netbook and it loaded successfully. But trying to load on the desktop I get the error " Apt configuration problem. An attempt to configure apt to install additional packages from the CD failed" The installer then crashes. I have nothing in the CD drive. I can boot the system from the USB drive and it works fine. I have tried all options on the load with the same crash each time. I baffled as I successfully loaded my netbook with the same USB with no problems.

    Read the article

  • The device is not ready

    - by hmloo
    When you retrieve the drive info using the DriveInfo class, if you don't use the IsReady property to test whether a drive is ready, it will throw error as "The device is not ready". so you must use IsReady property to determines if the drive is ready to be queried, written to, or read from. The following code example demonstrates querying information for all drives on current system. using System; using System.IO; class Test { public static void Main() { DriveInfo[] allDrives = DriveInfo.GetDrives(); foreach (DriveInfo d in allDrives) { Console.WriteLine("Drive {0}", d.Name); Console.WriteLine(" File type: {0}", d.DriveType); if (d.IsReady == true) { Console.WriteLine(" Volume label: {0}", d.VolumeLabel); Console.WriteLine(" File system: {0}", d.DriveFormat); Console.WriteLine( " Available space to current user:{0, 15} bytes", d.AvailableFreeSpace); Console.WriteLine( " Total available space: {0, 15} bytes", d.TotalFreeSpace); Console.WriteLine( " Total size of drive: {0, 15} bytes ", d.TotalSize); } } } }

    Read the article

  • Accidentally deleted my windows 7 while installing ubuntu, trying to reinstall it

    - by user286874
    I had Windows 7 Ultimate on my desktop and I believe have downloaded the correct ISO file. I've been trying to use GParted and UNetbootin to create a bootable usb by formatting to FAT32, flagging the boot box, and writing to the flash drive with UNetbootin, but there have been problems. When I select my flash drive in the BIOS, it just reflashes the BIOS stock MSI picture 4 times then boots to Ubuntu anyway. Details: it's a new computer, self-built, hasn't shown any problems in the past, got Windows 7 through r/softwareswap so it's a MSDN file, the flash drive is a Sandisk U3 Cruzer, I uninstalled the bloatware when Iwas using Windows 7, but in the BIOS it still comes up as "Sandisk U3 Cruzer" I don't have a cCD/DVD drive. I dont care if I have to completely delete ubuntu in the process, I just need Windows 7 back by monday. I think the problem is because of the cruzer and am going to pick up a different flash drive today.

    Read the article

  • Can I create two databases, each for different directories?

    - by Tim
    I have run Recoll which created a database for my data partition on my internal hard drive. The database is stored under my home partition in the same internal hard drive. I now want to run Recoll to create a database for a dicrectory on my external hard drive, and store this new database on that external hard drive, because my internal hard drive doesn't have enough space to hold the new database. I was wondering how to do that in Recoll? Note: my current Recoll was installed from software center of Ubuntu 12.04. Thanks!

    Read the article

  • Ubuntu 12.04 boot degraded raid

    - by beacon_bonanza
    I've installed Ubuntu 12.04.1 in a new server and set up the 4 hard drives with 3 RAID 1 devices, the configuration is such that the first two drives have md0 (swap space) and md1 (/) with the third and fourth drives having md2 (/var). I've been testing the operation under a drive failure and found that the system boots fine if I remove disk two but if I remove disk one then the system gets to grub and then just restarts. I'm confused as to why grub appears to be loading properly from disk two but then the boot fails. I've tried to copy the MBR from disk 1 to 2: dd if=/dev/sda of=/dev/sdb bs=512 count=1 but this didn't make a difference. Any ideas how to get it to boot from just the second disk? fdisk -l Disk /dev/sda: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000ccfa5 Device Boot Start End Blocks Id System /dev/sda1 2048 31250431 15624192 fd Linux RAID autodetect /dev/sda2 * 31250432 3907028991 1937889280 fd Linux RAID autodetect Disk /dev/sdb: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000ccfa5 Device Boot Start End Blocks Id System /dev/sdb1 2048 31250431 15624192 fd Linux RAID autodetect /dev/sdb2 * 31250432 3907028991 1937889280 fd Linux RAID autodetect Disk /dev/sdd: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00035b05 Device Boot Start End Blocks Id System /dev/sdd1 2048 3907028991 1953513472 fd Linux RAID autodetect Disk /dev/sdc: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000c73aa Device Boot Start End Blocks Id System /dev/sdc1 2048 3907028991 1953513472 fd Linux RAID autodetect Disk /dev/md1: 1984.3 GB, 1984264208384 bytes 2 heads, 4 sectors/track, 484439504 cylinders, total 3875516032 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md2: 2000.3 GB, 2000263380992 bytes 2 heads, 4 sectors/track, 488345552 cylinders, total 3906764416 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0: 16.0 GB, 15990652928 bytes 2 heads, 4 sectors/track, 3903968 cylinders, total 31231744 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Can MS Services for Unix be deployed and accessed from a shared drive?

    - by Ian C.
    I'm interested in experimenting with replacing our dependency on MKS with MS' Sevices for Unix toolset. I was wondering if anyone has any experience with deploying SFU on a shared drive? We like to, wherever possible, host our dev tools on one central NAS and call to the NAS to access the tools instead of rolling stuff out to each and every desktop. I'm not interested in the NFS support or ActiveState Perl. Really, none of the daemon technology is required here. I'm looking for replacements for the coreutils/binutils stuff you find in Linux (and MKS on Windows): sed, awk, csh, bash, grep, ls, find -- the meat-and-potates command line apps that our build and test scripts are built around. If I limit the install to just the Interix GNU Components (and maybe the Remote Connectivity components) will is run nicely from a shared location? To head off some questions: Yes, I've looked at Cygwin. Unfortunately it's performance in our build and test environment is poor. It runs considerably slower than MKS and it's not a direct drop-in replacement for MKS (thanks to its internal pathing and limitations with commands like 'ps'), so it's a tougher sell. Yes, I'm looking at the MinGW offering in parallel to this.

    Read the article

  • Is there a way to exclude a specific drive vdi from "snapshots" in VirtualBox?

    - by Graza
    ...or is there another space-efficient way of dealing with the page/swap file of the Guest O/S? I've realised that its quite possible/likely that one of the things which "bloats" the snapshot/diff vdi's when a snapshot is taken is the guest operating system's pagefile. For example, say I have a 2Gb swap-file in a Windows guest OS, and over the course of a few weeks the usage of the swap file has gone over 1Gb a couple of times. When I next create a snapshot, it seems likely that I'd be almost guaranteed around 1Gb of space taken up in the new differencing disk just because of changes in the swap file. Obviously (provided I never did "live" snapshots on running or paused machines, and only ever did them when the machine was shut down), I would not need any of the information in the swap file to be saved. So this would simply be a waste of 1Gb. I'm wondering if there's a way to attach a vdi to a VM and flag it as "exclude from snapshots" - which would mean I could put the swap file on a different vdi which would never be included in a snapshot. Or if anyone has any other suggestions. Or an explanation about why it might not be an issue. I could obviously delete and recreate a swap drive vdi every time I did a snapshot to achieve the same effect, but this is a little more effort than simply clicking "create snapshot"....

    Read the article

  • Why is a SUBST'd drive inaccessible via shortcut or Run menu, but works fine from My Computer?

    - by Kev
    I have shortcuts to C:, D:, and E: in my quick launch bar. C and E work fine when I click on them, but D does nothing (that I can see) when I click on it. D and E are both SUBST'd drives pointing to folders that happen to be network shares. (I do this rather than mapping them so it doesn't have to go through the network layer--that way it works faster and I still get recycle bin functionality, etc.) If I go Start-Run and type D: or D:\, I get an error box saying This file does not have a program associated with it for performing this action. Create an association in the Folder Options control panel. If I go to My Computer and double-click the D drive, it comes up fine. Also, if I type \\servername\sharename pointing to the same place, it comes up fine. This just started happening this morning, out of the blue. It has been working fine ever since I set it up. Why might this be?

    Read the article

  • How do I access my samba drive through several layers of network topology?

    - by stephenmm
    I have a new windows 7 Home Premium machine that is in a different room than my main computer area. As such I have to use a bridge and another router. Everything is working wonderfully except I cannot access the SAMBA drive with the new machine. I know that SAMBA is accessible as an older WinXP machine can access it. A picture of my network would probably be helpfull: To ISP | | +---------------------------+ | WAN | | Cable Modem | | (2WIRE678) | | | | | +---------------------------+ | +---------------------------+ | | (|) (|) +-----------+ | Belkin Router | | | | Wireless | | (F5D) |--+ +--| WinXP | | | |SAMBA USER | | | +-----------+ +---------------------------+ | | | | +------------+ | | Ubuntu | | | Apache + | | |SAMBA Server| | +------------+ | | +---------------------------+ | | | Netgear Bridge | | (XET1001) | | | +---------------------------+ # # +---------------------------+ | | | Netgear Bridge | | (XET1001) | | | +---------------------------+ | +---------------------------+ | | | D-Link Router | | (DI-524) | | | | | +---------------------------+ | | | | +-----------+ | | | Win7 | |SAMBA USER?| +-----------+ More interesting data points: 1. I can ping the SAMBA server from the Win7 machine locally (Ie. 192.168.2.2) 2. I can access the webserver from the Win7 machine locally (Ie. 192.168.2.2) 3. I followed the advice to get Win7 and SAMBA to play nice: http://www.tannerwilliamson.com/2009/09/windows-7-seven-network-file-sharing-fix-samba-smb/ Sorry for being so long winded but it is kind of complex and I am really at a loss as to how to fix it. If any of you have some suggestions I would love to hear it!

    Read the article

  • How do I mount an external USB hard drive on my Sheevaplug?

    - by James
    I've acquired a Sheevaplug running - I think - Ubuntu. I'd like to mount an external USB hard drive, but I don't know the name of the device that needs mounting. When I list the devices under /dev, a long list is produced. How do I find out which device listed needs to be mounted? Update: When I run dmesg after plugging the device in, I see the following at the end: usb 1-1: new high speed USB device using ehci_marvell and address 6 usb 1-1: device not accepting address 6, error -71 usb 1-1: new high speed USB device using ehci_marvell and address 7 usb 1-1: device not accepting address 7, error -71 usb 1-1: new high speed USB device using ehci_marvell and address 8 usb 1-1: device not accepting address 8, error -71 usb 1-1: new high speed USB device using ehci_marvell and address 9 usb 1-1: device not accepting address 9, error -71 And when I view /var/log/messages, I can see this: Sep 23 21:26:03 debian kernel: usb 1-1: new high speed USB device using ehci_ma$ Sep 23 21:26:04 debian kernel: usb 1-1: new high speed USB device using ehci_ma$ Sep 23 21:26:05 debian kernel: usb 1-1: new high speed USB device using ehci_ma$ Sep 23 21:26:05 debian kernel: usb 1-1: new high speed USB device using ehci_ma$ Unfortunately, I don't know what these mean.

    Read the article

  • How to safely move where itunes saves music/iphone apps/and meta data to another internal Drive?

    - by GingerLee
    In the past, when I have moved my itunes data from one computer to another, I usually just follow these steps: Copy the contents of two folders: %USERPROFILE%\Music\iTunes %USERPROFILE%\AppData\Roaming\Apple Computer 1) Install iTunes on the new computer, start it and close it (don't let it search for music). 2) Copy all the files in the above folders from old PC to new PC. 3) Start iTunes and authorize the new computer (and deauthorize old one). 4) Before syncing, update all iphone apps to current versions on both my iphone and in itunes. 5) The Sync. The above steps always work for me, and basically Itunes on my new PC works exactly as it did on the old PC. My Question: In the hopes of bybassing the above steps in the future, I would like to just have Itunes use another internal Drive that I use for file storage (e.g. D:/) as the path for the above two directory? Then if I move to new PC again, I could just setup itunes to use the correct path. Is that possible yet with minimal implications? If so how?

    Read the article

  • Is this DVD drive broken? Brand new, i need help convincing

    - by acidzombie24
    I am asking bc i know dell is going to give me a problem. How do i know if my DVD is broken on my laptop? i burnt 4 DL disc and they ALL failed, i called and dell suggested roxio. I used it and burnt 1 disc without error and the 2nd disc with an error. With both apps there were no 'problems' during the burning process only failed on the verification process. Some of these bad disc dont work on other PCs and one locks up windows when i click a specific file. Does that sound like a broken burner to you guys? when i called dell they told me since it can read disc properly 100% of the time and software doesnt fail in the burning process its not a broken drive _. They forward me to software support who demand a fee (i think $100) to help me fix my software. I am annoyed bc i dont want to be on the phone for them to watch me burn a dvd and since i burned it once correctly i dont want to happen to burn correctly again to have them say they solved my problem (doing nothing) and charge me refusing to refund. -edit- The errors i got were 1) the request could not be performed because of an I/O device error 2) Windows locking up when opening 1 specific file 3) Cannot copy : Data error (crc) NOTE: the file that causes the problems are random every disc

    Read the article

  • How many bootable partitions are possible to have on one hard drive?

    - by draiden
    This may not be the correct place to post this; if that's the case, just let me know and point me in the right direction please! I'm thinking of building a box that needs to be lightweight and portable, and would need to be able to boot multiple installations of windows. I am needing to have multiple installations so that I can, for example, plug the box in to the network at one location, boot in to that location's partition, and have full access to everything I would normally need to do on a computer that has already been set up on that network. Then, when I go to the next client, I would be able to do the same thing, with the new location's partition, and have all of those network settings, drive mappings, etc., available there. Obviously I'd need to go through and set them all up on the different locations/networks, I'm not expecting it to magically know where I am and what I'm doing. It would be like I'm carrying around a computer that is configured for each place I need to go in one little box, instead of having to have multiple computers or having to reconfigure all the settings and such every time I go to another client. Or is there an easier way to do this that I haven't learned of?

    Read the article

  • How many bootable partitions are possible to have on one hard drive?

    - by draiden
    This may not be the correct place to post this; if that's the case, just let me know and point me in the right direction please! I'm thinking of building a box that needs to be lightweight and portable, and would need to be able to boot multiple installations of windows. I am needing to have multiple installations so that I can, for example, plug the box in to the network at one location, boot in to that location's partition, and have full access to everything I would normally need to do on a computer that has already been set up on that network. Then, when I go to the next client, I would be able to do the same thing, with the new location's partition, and have all of those network settings, drive mappings, etc., available there. Obviously I'd need to go through and set them all up on the different locations/networks, I'm not expecting it to magically know where I am and what I'm doing. It would be like I'm carrying around a computer that is configured for each place I need to go in one little box, instead of having to have multiple computers or having to reconfigure all the settings and such every time I go to another client. Or is there an easier way to do this that I haven't learned of?

    Read the article

  • Customize your icons in Windows 7 and Vista

    - by Matthew Guay
    Want to change out the icons on your desktop and more?  Personalizing your icons is a great way to make your PC uniquely yours,, and today we show you how to grab unique icons, and default Winnows. to be your own. Change the icon for Computer, Recycle Bin, Network, and your User folder Right-click on the desktop, and select Personalize. Now, click the “Change desktop icons” link on the left sidebar in the Personalization window. The window looks slightly different in Windows Vista, but the link is the same. Select the icon you wish to change, and click the Change Icon button.  In Windows 7, you will also notice a box to choose whether or not to allow themes to change icons, and you can uncheck it if you don’t want themes to change your icon settings. You can select one of the other included icons, or click browse to find the icon you want.  Click Ok when you are finished. Change Folder icons You can easily change the icon on most folders in Windows Vista and 7.  Simply right-click on the folder and select properties. Click the Customize tab, and then click the Change Icon button.  This will open the standard dialog to change your icon, so proceed as normal. This basically just creates a hidden desktop.ini file in the folder containing the following or similar data: [.ShellClassInfo]IconFile=%SystemRoot%\system32\SHELL32.dllIconIndex=20 You could manually create or edit the file if you choose, instead of using the dialogs. Simply create a new text file named desktop.ini with this same information, or edit the existing one.  Change the IconFile line to the location of your icon. If you are pointing to a .ico file you should change the IconIndex line to 0 instead. Note that this isn’t available for all folders, for instance you can’t use this to change the icon for the Windows folder.   In Windows 7, please note that you cannot change the icon of folder inside a library.  So if you are browsing your Documents library and would like to change an icon in that folder, right-click on it and select Open folder location.  Now you can change the icon as above. And if you would like to change a Library’s icon itself, then check out this tutorial: Change Your Windows 7 Library Icons the Easy Way Change the icon of any file type Want to make you files easier to tell apart?  Check out our tutorial on how to simply do this: Change a File Type’s Icon in Windows 7 Change the icon of any Application Shortcut To change the icon of a shortcut on your desktop, start menu, or in Explorer, simply right-click on the icon and select Properties. In the Shortcut tab, click the Change Icon button. Now choose one of the other available icons or click browse to find the icon you want. Change Icons of Running Programs in the Windows 7 taskbar If your computer is running Windows 7, you can customize the icon of any program running in the taskbar!  This only works on applications that are running but not pinned to the taskbar, so if you want to customize a pinned icon you may want to unpin it before customizing it.  But the interesting thing about this trick is that it can customize any icon anything running in the taskbar, including things like Control Panel! Right-click or click and push up to open the jumplist on the icon, and then right-click on the program’s name and select Properties.  Here we are customizing Control Panel, but you can do this on any application icon. Now, click Change Icon as usual. Select an icon you want (We switched the Control Panel icon to the Security Shield), or click Browse to find another icon.  Click Ok when finished, and then close the application window. The next time you open the program (or Control Panel in our example), you will notice your new icon on its taskbar icon. Please note that this only works on applications that are currently running and are not pinned to the taskbar.  Strangely, if the application is pinned to the taskbar, you can still click Properties and change the icon, but the change will not show up. Change the icon on any Drive on your Computer You can easily change the icon on your internal hard drives and portable drives with the free Drive Icon Changer application.  Simply download and unzip the file (link below), and then run the application as administrator by right-clicking on the icon and selecting “Run as administrator”. Now, select the drive that you want to change the icon of, and select your desired icon file. Click Save, and Drive Icon Changer will let you know that the icon has been changed successfully. You will then need to reboot your computer to complete the changes.  Simply click Yes to reboot. Now, our Drive icon is changed from this default image: to a Laptop icon we chose! You can do this to any drive in your computer, or to removable drives such as USB flash drives.  When you change these drives icons, the new icon will appear on any computer you insert the drive into.  Also, if you wish to remove the icon change, simply run the Drive Icon Changer again and remove the icon path. Download Drive Icon Changer This application actually simply creates or edits a hidden Autorun.inf file on the top of your drive.  You can edit or create the file yourself by hand if you’d like; simply include the following information in the file, and save it in the top directory of your drive: [autorun]ICON=[path of your icon] Remove Arrow from shortcut icons Many people don’t like the arrow on the shortcut icon, and there are two easy ways to do this. If you’re running the 32 bit version of Windows Vista or 7, simply use the Vista Shortcut Overlay Remover. If your computer is running the 64 bit version of Windows Vista or 7, use the Ultimate Windows Tweaker instead.  Simply select the Additional Tweaks section, and check the “Remove arrows from Shortcut Icons.” For more info and download links check out this article: Disable Shortcut Icon Arrow Overlay in Windows 7 or Vista Closing: This gives you a lot of ways to customize almost any icon on your computer, so you can make it look just like you want it to.  Stay tuned for more great desktop customization articles from How-to Geek! Similar Articles Productive Geek Tips Change Start Menu to Use Small Icons in Windows 7 or VistaResize Icons Quickly in Windows 7 or Vista ExplorerRoundup: 16 Tweaks to Windows Vista Look & FeelRestore Missing Desktop Icons in Windows 7 or VistaClean Up Past Notification Icons in Windows Vista TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Change DNS servers on the fly with DNS Jumper Live PDF Searches PDF Files and Ebooks Converting Mp4 to Mp3 Easily Use Quick Translator to Translate Text in 50 Languages (Firefox) Get Better Windows Search With UltraSearch Scan News With NY Times Article Skimmer

    Read the article

  • Change or Reset Windows Password from a Ubuntu Live CD

    - by Trevor Bekolay
    If you can’t log in even after trying your twelve passwords, or you’ve inherited a computer complete with password-protected profiles, worry not – you don’t have to do a fresh install of Windows. We’ll show you how to change or reset your Windows password from a Ubuntu Live CD. This method works for all of the NT-based version of Windows – anything from Windows 2000 and later, basically. And yes, that includes Windows 7. You’ll need a Ubuntu 9.10 Live CD, or a bootable Ubuntu 9.10 Flash Drive. If you don’t have one, or have forgotten how to boot from the flash drive, check out our article on creating a bootable Ubuntu 9.10 flash drive. The program that lets us manipulate Windows passwords is called chntpw. The steps to install it are different in 32-bit and 64-bit versions of Ubuntu. Installation: 32-bit Open up Synaptic Package Manager by clicking on System at the top of the screen, expanding the Administration section, and clicking on Synaptic Package Manager. chntpw is found in the universe repository. Repositories are a way for Ubuntu to group software together so that users are able to choose if they want to use only completely open source software maintained by Ubuntu developers, or branch out and use software with different licenses and maintainers. To enable software from the universe repository, click on Settings > Repositories in the Synaptic window. Add a checkmark beside the box labeled “Community-maintained Open Source software (universe)” and then click close. When you change the repositories you are selecting software from, you have to reload the list of available software. In the main Synaptic window, click on the Reload button. The software lists will be downloaded. Once downloaded, Synaptic must rebuild its search index. The label over the text field by the Search button will read “Rebuilding search index.” When it reads “Quick search,” type chntpw in the text field. The package will show up in the list. Click on the checkbox near the chntpw name. Click on Mark for Installation. chntpw won’t actually be installed until you apply the changes you’ve made, so click on the Apply button in the Synaptic window now. You will be prompted to accept the changes. Click Apply. The changes should be applied quickly. When they’re done, click Close. chntpw is now installed! You can close Synaptic Package Manager. Skip to the section titled Using chntpw to reset your password. Installation: 64-bit The version of chntpw available in Ubuntu’s universe repository will not work properly on a 64-bit machine. Fortunately, a patched version exists in Debian’s Unstable branch, so let’s download it from there and install it manually. Open Firefox. Whether it’s your preferred browser or not, it’s very readily accessible in the Ubuntu Live CD environment, so it will be the easiest to use. There’s a shortcut to Firefox in the top panel. Navigate to http://packages.debian.org/sid/amd64/chntpw/download and download the latest version of chntpw for 64-bit machines. Note: In most cases it would be best to add the Debian Unstable branch to a package manager, but since the Live CD environment will revert to its original state once you reboot, it’ll be faster to just download the .deb file. Save the .deb file to the default location. You can close Firefox if desired. Open a terminal window by clicking on Applications at the top-left of the screen, expanding the Accessories folder, and clicking on Terminal. In the terminal window, enter the following text, hitting enter after each line: cd Downloadssudo dpkg –i chntpw* chntpw will now be installed. Using chntpw to reset your password Before running chntpw, you will have to mount the hard drive that contains your Windows installation. In most cases, Ubuntu 9.10 makes this simple. Click on Places at the top-left of the screen. If your Windows drive is easily identifiable – usually by its size – then left click on it. If it is not obvious, then click on Computer and check out each hard drive until you find the correct one. The correct hard drive will have the WINDOWS folder in it. When you find it, make a note of the drive’s label that appears in the menu bar of the file browser. If you don’t already have one open, start a terminal window by going to Applications > Accessories > Terminal. In the terminal window, enter the commands cd /medials pressing enter after each line. You should see one or more strings of text appear; one of those strings should correspond with the string that appeared in the title bar of the file browser earlier. Change to that directory by entering the command cd <hard drive label> Since the hard drive label will be very annoying to type in, you can use a shortcut by typing in the first few letters or numbers of the drive label (capitalization matters) and pressing the Tab key. It will automatically complete the rest of the string (if those first few letters or numbers are unique). We want to switch to a certain Windows directory. Enter the command: cd WINDOWS/system32/config/ Again, you can use tab-completion to speed up entering this command. To change or reset the administrator password, enter: sudo chntpw SAM SAM is the file that contains your Windows registry. You will see some text appear, including a list of all of the users on your system. At the bottom of the terminal window, you should see a prompt that begins with “User Edit Menu:” and offers four choices. We recommend that you clear the password to blank (you can always set a new password in Windows once you log in). To do this, enter “1” and then “y” to confirm. If you would like to change the password instead, enter “2”, then your desired password, and finally “y” to confirm. If you would like to reset or change the password of a user other than the administrator, enter: sudo chntpw –u <username> SAM From here, you can follow the same steps as before: enter “1” to reset the password to blank, or “2” to change it to a value you provide. And that’s it! Conclusion chntpw is a very useful utility provided for free by the open source community. It may make you think twice about how secure the Windows login system is, but knowing how to use chntpw can save your tail if your memory fails you two or eight times! Similar Articles Productive Geek Tips Reset Your Ubuntu Password Easily from the Live CDChange Your Forgotten Windows Password with the Linux System Rescue CDHow to Create and Use a Password Reset Disk in Windows Vista & Windows 7Reset Your Forgotten Password the Easy Way Using the Ultimate Boot CD for WindowsHow to install Spotify in Ubuntu 9.10 using Wine TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Add a Custom Title in IE using Spybot or Spyware Blaster When You Need to Hail a Taxi in NYC Live Map of Marine Traffic NoSquint Remembers Site Specific Zoom Levels (Firefox) New Firefox release 3.6.3 fixes 1 Critical bug Dark Side of the Moon (8-bit)

    Read the article

  • What to Do When Windows Won’t Boot

    - by Chris Hoffman
    You turn on your computer one day and Windows refuses to boot — what do you do? “Windows won’t boot” is a common symptom with a variety of causes, so you’ll need to perform some troubleshooting. Modern versions of Windows are better at recovering from this sort of thing. Where Windows XP might have stopped in its tracks when faced with this problem, modern versions of Windows will try to automatically run Startup Repair. First Things First Be sure to think about changes you’ve made recently — did you recently install a new hardware driver, connect a new hardware component to your computer, or open your computer’s case and do something? It’s possible the hardware driver is buggy, the new hardware is incompatible, or that you accidentally unplugged something while working inside your computer. The Computer Won’t Power On At All If your computer won’t power on at all, ensure it’s plugged into a power outlet and that the power connector isn’t loose. If it’s a desktop PC, ensure the power switch on the back of its case — on the power supply — is set to the On position. If it still won’t power on at all, it’s possible you disconnected a power cable inside its case. If you haven’t been messing around inside the case, it’s possible the power supply is dead. In this case, you’ll have to get your computer’s hardware fixed or get a new computer. Be sure to check your computer monitor — if your computer seems to power on but your screen stays black, ensure your monitor is powered on and that the cable connecting it to your computer’s case is plugged in securely at both ends. The Computer Powers On And Says No Bootable Device If your computer is powering on but you get a black screen that says something like “no bootable device” or another sort of “disk error” message, your computer can’t seem to boot from the hard drive that Windows was installed on. Enter your computer’s BIOS or UEFI firmware setup screen and check its boot order setting, ensuring that it’s set to boot from its hard drive. If the hard drive doesn’t appear in the list at all, it’s possible your hard drive has failed and can no longer be booted from. In this case, you may want to insert Windows installation or recovery media and run the Startup Repair operation. This will attempt to make Windows bootable again. For example, if something overwrote your Windows drive’s boot sector, this will repair the boot sector. If the recovery environment won’t load or doesn’t see your hard drive, you likely have a hardware problem. Be sure to check your BIOS or UEFI’s boot order first if the recovery environment won’t load. You can also attempt to manually fix Windows boot loader problems using the fixmbr and fixboot commands. Modern versions of Windows should be able to fix this problem for you with the Startup Repair wizard, so you shouldn’t actually have to run these commands yourself. Windows Freezes or Crashes During Boot If Windows seems to start booting but fails partway through, you may be facing either a software or hardware problem. If it’s a software problem, you may be able to fix it by performing a Startup Repair operation. If you can’t do this from the boot menu, insert a Windows installation disc or recovery disk and use the startup repair tool from there. If this doesn’t help at all, you may want to reinstall Windows or perform a Refresh or Reset on Windows 8. If the computer encounters errors while attempting to perform startup repair or reinstall Windows, or the reinstall process works properly and you encounter the same errors afterwards, you likely have a hardware problem. Windows Starts and Blue Screens or Freezes If Windows crashes or blue-screens on you every time it boots, you may be facing a hardware or software problem. For example, malware or a buggy driver may be loading at boot and causing the crash, or your computer’s hardware may be malfunctioning. To test this, boot your Windows computer in safe mode. In safe mode, Windows won’t load typical hardware drivers or any software that starts automatically at startup. If the computer is stable in safe mode, try uninstalling any recently installed hardware drivers, performing a system restore, and scanning for malware. If you’re lucky, one of these steps may fix your software problem and allow you to boot Windows normally. If your problem isn’t fixed, try reinstalling Windows or performing a Refresh or Reset on Windows 8. This will reset your computer back to its clean, factory-default state. If you’re still experiencing crashes, your computer likely has a hardware problem. Recover Files When Windows Won’t Boot If you have important files that will be lost and want to back them up before reinstalling Windows, you can use a Windows installer disc or Linux live media to recover the files. These run entirely from a CD, DVD, or USB drive and allow you to copy your files to another external media, such as another USB stick or an external hard drive. If you’re incapable of booting a Windows installer disc or Linux live CD, you may need to go into your BIOS or UEFI and change the boot order setting. If even this doesn’t work — or if you can boot from the devices and your computer freezes or you can’t access your hard drive — you likely have a hardware problem. You can try pulling the computer’s hard drive, inserting it into another computer, and recovering your files that way. Following these steps should fix the vast majority of Windows boot issues — at least the ones that are actually fixable. The dark cloud that always hangs over such issues is the possibility that the hard drive or another component in the computer may be failing. Image Credit: Karl-Ludwig G. Poggemann on Flickr, Tzuhsun Hsu on Flickr     

    Read the article

  • Recover lost NTFS partition on SSD

    - by Emil
    Hello, About 2 month ago I upgraded my Dell Latitude E6500 laptop with a Corsair Force F120 SSD drive. Everything worked well until about a week or so back. I started the computer and was faced with a beep and a message saying "No boot sector on Internal HDD (IRRT). No bootable devices". Since I figured that the boot sector had somehow got corrupt I tried booting from the Windows 7 dvd in order to repair the boot sector. But the Windows 7 installation program only found a blank drive with 111GB of unallocated space. I panicked and brought the drive with me to work to let a colleague have a look at it. We made a disk image of the entire drive and ran the drive through Testdisk in Linux. Testdisk did not find any partitions. It appears that the drive has been completely erased... What has happened? What is causing this behavior on an SSD?

    Read the article

  • How to remove raid 5 array of 5 SAS and use only use one SAS at a time without writing any thing to disc for recovery

    - by murtaza hamid
    I have HP server ML370 g5 with 8 SAS, c drive 1 72 gb raid 0, d drive 2 72 gb raid 0, f drive 5 146 gb raid 5. 2 of 5 sas drive has got bad sectors and raid 5 is showing status failed. now i want to remove all this 5 SAS and put 1 by 1 in any of the bay to make its image for data recovery purpose without writing anything to the drive. how should i proceed. i also want to keep drive c and d intact. also is it possible if i put all this 5 drives in the bay with the same sequense will it recognise the raid 5 array ( i read some where its smart controller..just curious) many thanks in advance.

    Read the article

  • Ubuntu only boots with USB plugged in

    - by Ben
    I'm new to the Linux world so please bear with me! :-) I installed Ubuntu via USB drive onto my hard drive. If I boot the PC without the usb drive I used, Ubuntu will not load. After booting I can unplug without any consequences. I looked on the hard drive and there is a boot folder. On the USB drive, this is the tree contents: /media/disk$ tree . |-- adtext.cfg |-- boot.cat |-- f10.txt |-- f1.txt |-- f2.txt |-- f3.txt |-- f4.txt |-- f5.txt |-- f6.txt |-- f7.txt |-- f8.txt |-- f9.txt |-- initrd.gz |-- isolinux.bin |-- isolinux.cfg |-- ldlinux.sys |-- linux |-- menu.c32 |-- menu.cfg |-- po4a.cfg |-- prompt.cfg |-- splash.png |-- stdmenu.cfg |-- syslinux.cfg |-- text.cfg |-- ubnfilel.txt |-- ubnpathl.txt `-- vesamenu.c32 Am I correct in my assumption that the boot aspect is associated to the USB drive? If so, how do I get it to boot without the USB? I'm guessing copying into some location and modifying grub?

    Read the article

  • KVM Guest installed from console. But how to get to the guest's console?

    - by badbishop
    I'm trying to install a fully virtualized guest (Fedora 14 x86_64) on KVM (RHEL 6), using command-line only (both hypervisor and guest). It goes without errors, and without a tangible result . I'd like to know how to do a text-only installation. So, here's what I've done: # virt-install \ --name=FE --ram=756 --vcpus=1 \ --file=/var/lib/libvirt/images/FE.img --network bridge:br0 \ --nographics --os-type=linux \ --extra-args='console=tty0' -v \ --cdrom=/media/usb/Fedora-14-x86_64-Live-Desktop.iso Starting install... Creating domain... | 0 B 00:00 Connected to domain FE Escape character is ^] ÿ Now what? As I understand after googling for a couple of days, I should see the guest's output from the text installation, but nothing happens. virt-viewer cannot connect to it, kindly suggesting that I explore all the options by adding --help (which I did). If I reconnect with virsh, I see this: Domain installation still in progress. You can reconnect to the console to complete the installation process. [root@v ~] # virsh console FEConnected to domain FE Escape character is ^] This shows that VM is running # virsh list Id Name State ---------------------------------- 8 FE running Qemu log: LC_ALL=C PATH=/sbin:/usr/sbin:/bin:/usr/bin /usr/libexec/qemu-kvm -S -M rhel6.0.0 -enable-kvm -m 756 -smp 1,sockets=1,cores=1,threads=1 -name FE -uuid 6989d008-7c89-424c-d2d3-f41235c57a18 -nographic -nodefconfig -nodefaults -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/FE.monitor,server,nowait -mon chardev=monitor,mode=control -rtc base=utc -no-reboot -boot d -drive file=/var/lib/libvirt/images/FE.img,if=none,id=drive-ide0-0-0,format=raw,cache=none -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive file=/media/usb/Fedora-14-x86_64-Live-Desktop.iso,if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -netdev tap,fd=20,id=hostnet0 -device rtl8139,netdev=hostnet0,id=net0,mac=52:54:00:0a:65:8d,bus=pci.0,addr=0x2 -chardev pty,id=serial0 -device isa-serial,chardev=serial0 -usb -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x3 char device redirected to /dev/pts/1 Output of /etc/libvirt/qemu/FE.xml # cat /etc/libvirt/qemu/FE.xml <domain type='kvm'> <name>FE</name> <uuid>6989d008-7c89-424c-d2d3-f41235c57a18</uuid> <memory>774144</memory> <currentMemory>774144</currentMemory> <vcpu>1</vcpu> <os> <type arch='x86_64' machine='rhel6.0.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw' cache='none'/> <source file='/var/lib/libvirt/images/FE.img'/> <target dev='hda' bus='ide'/> <address type='drive' controller='0' bus='0' unit='0'/> </disk> <disk type='block' device='cdrom'> <driver name='qemu' type='raw'/> <target dev='hdc' bus='ide'/> <readonly/> <address type='drive' controller='0' bus='1' unit='0'/> </disk> <controller type='ide' index='0'> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x1'/> </controller> <interface type='bridge'> <mac address='52:54:00:0a:65:8d'/> <source bridge='br0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/> </interface> <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target port='0'/> </console> <memballoon model='virtio'> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </memballoon> </devices> </domain> I'm obviously missing something that many others don't, but what is it? Thanx in advance!

    Read the article

< Previous Page | 152 153 154 155 156 157 158 159 160 161 162 163  | Next Page >