  • How to get more information from the system crash

    - by viraptor
    I'd like to debug an issue I'm having with a linux (debian stable) server, but I'm running out of ideas of how to confirm any diagnosis. Some background: The servers are running DL160 class with hardware raid between two disks. They're running a lot of services, mostly utilising network interface and CPU. There are 8 cpus and 7 "main" most cpu-hungry processes are bound to one core each via cpu affinity. Other random background scripts are not forced anywhere. The filesystem is writing ~1.5k blocks/s the whole time (goes up above 2k/s in peak times). Normal CPU usage for those servers is ~60% on 7 cores and some minimal usage on the last (whatever's running on shells usually). What actually happens is that the "main" services start using 100% CPU at some point, mainly stuck in kernel time. After a couple of seconds, LA goes over 400 and we lose any way to connect to the box (KVM is on it's way, but not there yet). Sometimes we see a kernel reporting hung task (but not always): [118951.272884] INFO: task zsh:15911 blocked for more than 120 seconds. [118951.272955] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. [118951.273037] zsh D 0000000000000000 0 15911 1 [118951.273093] ffff8101898c3c48 0000000000000046 0000000000000000 ffffffffa0155e0a [118951.273183] ffff8101a753a080 ffff81021f1c5570 ffff8101a753a308 000000051f0fd740 [118951.273274] 0000000000000246 0000000000000000 00000000ffffffbd 0000000000000001 [118951.273335] Call Trace: [118951.273424] [<ffffffffa0155e0a>] :ext3:__ext3_journal_dirty_metadata+0x1e/0x46 [118951.273510] [<ffffffff804294f6>] schedule_timeout+0x1e/0xad [118951.273563] [<ffffffff8027577c>] __pagevec_free+0x21/0x2e [118951.273613] [<ffffffff80428b0b>] wait_for_common+0xcf/0x13a [118951.273692] [<ffffffff8022c168>] default_wake_function+0x0/0xe .... This would point at raid / disk failure, however sometimes the tasks are hung on kernel's gettsc which would indicate some general weird hardware behaviour. It's also running mysql (almost read-only, 99% cache hit), which seems to spawn a lot more threads during the system problems. During the day it does ~200kq/s (selects) and ~10q/s (writes). The host is never running out of memory or swapping, no oom reports are spotted. We've got many boxes with similar/same hardware and they all seem to behave that way, but I'm not sure which part fails, so it's probably not a good idea to just grab something more powerful and hope the problem goes away. Applications themselves don't really report anything wrong when they're running. I can run anything safely on the same hardware in an isolated environment. What can I do to narrow down the problem? Where else should I look for explanation?

    Read the article

  • NAS Performance issues

    - by Markus
    I bought a NAS from Conceptronic CH3MNAS and built in two Western Digital 1,5TB Green Drives. I only get a write speed of 6mb/s in LAN The configuration of the drives is as follows: - Raid 0 - EXT2 Is that a normal speed?

    Read the article

  • Best Free Windows Imaging Software For Servers

    - by Justin
    We are running two physical servers both Windows 2003, not virtualized. What is the best free (if any) windows software to take a full image backup of the entire drives? If possible, while the image is taking place, it should not bring the hosts to their knees with excess CPU or I/O usage. The servers have RAID mirroring, but after hearing a few horror stories about hacked systems, we need to have weekly full image backups, so we can simply revert to a pre-hacked image. Thanks.

    Read the article

  • Improving TCP performance over a gigabit network lots of connections and high traffic for storage and streaming services

    - by Linux Guy
    I have two servers, Both servers hardware Specification are Processor : Dual Processor RAM : over 128 G.B Hard disk : SSD Hard disk Outging Traffic bandwidth : 3 Gbps network cards speed : 10 Gbps Server A : for Encoding videos Server B : for storage videos andstream videos over web interface like youtube The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos Both servers in same network , when i do ping from Server A to Server B i got high time latency above 1.0ms , the time range time=52.7 ms to time=215.7 ms - This is the output of iftop utility 353Mb 707Mb 1.04Gb 1.38Gb 1.73Gb mqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqq server.example.com => ip.address 6.36Mb 4.31Mb 1.66Mb <= 158Kb 94.8Kb 35.1Kb server.example.com => ip.address 1.23Mb 4.28Mb 1.12Mb <= 17.1Kb 83.5Kb 21.9Kb server.example.com => ip.address 395Kb 3.89Mb 1.07Mb <= 6.09Kb 109Kb 28.6Kb server.example.com => ip.address 4.55Mb 3.83Mb 1.04Mb <= 55.6Kb 45.4Kb 13.0Kb server.example.com => ip.address 649Kb 3.38Mb 1.47Mb <= 9.00Kb 38.7Kb 16.7Kb server.example.com => ip.address 5.00Mb 3.32Mb 1.80Mb <= 65.7Kb 55.1Kb 29.4Kb server.example.com => ip.address 387Kb 3.13Mb 1.06Mb <= 18.4Kb 39.9Kb 15.0Kb server.example.com => ip.address 3.27Mb 3.11Mb 1.01Mb <= 81.2Kb 64.5Kb 20.9Kb server.example.com => ip.address 1.75Mb 3.08Mb 2.72Mb <= 16.6Kb 35.6Kb 32.5Kb server.example.com => ip.address 1.75Mb 2.90Mb 2.79Mb <= 22.4Kb 32.6Kb 35.6Kb server.example.com => ip.address 3.03Mb 2.78Mb 1.82Mb <= 26.6Kb 27.4Kb 20.2Kb server.example.com => ip.address 2.26Mb 2.66Mb 1.36Mb <= 51.7Kb 49.1Kb 24.4Kb server.example.com => ip.address 586Kb 2.50Mb 1.03Mb <= 4.17Kb 26.1Kb 10.7Kb server.example.com => ip.address 2.42Mb 2.49Mb 2.44Mb <= 31.6Kb 29.7Kb 29.9Kb server.example.com => ip.address 2.41Mb 2.46Mb 2.41Mb <= 26.4Kb 24.5Kb 23.8Kb server.example.com => ip.address 2.37Mb 2.39Mb 2.40Mb <= 28.9Kb 27.0Kb 28.5Kb server.example.com => ip.address 525Kb 2.20Mb 1.05Mb <= 7.03Kb 26.0Kb 12.8Kb qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq TX: cum: 102GB peak: 1.65Gb rates: 1.46Gb 1.44Gb 1.48Gb RX: 1.31GB 24.3Mb 19.5Mb 18.9Mb 20.0Mb TOTAL: 103GB 1.67Gb 1.48Gb 1.46Gb 1.50Gb I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.2 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.2, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.1 port 38895 connected with 0.0.0.2 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes ifconfig server A eth0 Link encap:Ethernet HWaddr 00:25:90:ED:9E:AA inet addr:0.0.0.1 Bcast:0.0.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1202795665 errors:0 dropped:64334 overruns:0 frame:0 TX packets:2313161968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:893413096188 (832.0 GiB) TX bytes:3360949570454 (3.0 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:2207544 errors:0 dropped:0 overruns:0 frame:0 TX packets:2207544 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:247769175 (236.2 MiB) TX bytes:247769175 (236.2 MiB) ifconfig Server B eth2 Link encap:Ethernet HWaddr 00:25:90:82:C4:FE inet addr:0.0.0.2 Bcast:0.0.0.2 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:39973046980 errors:0 dropped:1828387600 overruns:0 frame:0 TX packets:69618752480 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3013976063688 (2.7 TiB) TX bytes:102250230803933 (92.9 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:1049495 errors:0 dropped:0 overruns:0 frame:0 TX packets:1049495 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:129012422 (123.0 MiB) TX bytes:129012422 (123.0 MiB) Netstat -i on Server B # netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth2 9000 0 42098629968 0 2131223717 0 73698797854 0 0 0 BMRU lo 65536 0 1077908 0 0 0 1077908 0 0 0 LRU I Turn up send/receive buffers on the network card to 2048 and problem still persist I increase the MTU for server A and problem still persist and i increase the MTU for server B for better connectivity and transfer speed but it couldn't transfer at all The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service in server B the transfer in server A at full speed, after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • Windows XP Professional Version 2002 SP3 restarts when I try to Hibernate

    - by dario_ramos
    I googled this and tried some solutions, but nothing seems to work. In the past, Hibernate worked fine. Someone told me that this can be caused by specific hardware, and I have lots of that, because this is a dev machine which we use to develop modules that interact with lots of different hardware. Moreover, this machine also uses RAID, which might have something to do. Is there any way to troubleshoot this by looking at some log file or using some tool?

    Read the article

  • squid cache disk configuration

    - by Gogonez
    just wondering how far drive configuration will affect squid cache performance. what kind of drive configuration that fast enough for squid ? is it true that block-level parity strip raid faster than byte-level one ? is mirrored drive config will decrease squid cache write process ? how much swap space that squid realy need to store cache (reverse mode) for 200mb web doc ? what kind of benchmark should i do to analyze squid disk performance ?

    Read the article

  • HP Smart Array p400i with Intel X25-M 160 SSD

    - by user67304
    I have a pair of x25-M 160 Intel SSD's in an HP DL360 G5 with a p400i Smart Array running 512 BBWC. The disk performance I am getting on this box and another identical one does not come close to matching the same two drives running through a cheap 3ware RAID card. Any idea? I have played with the cache settings, but nothing allows me to get the same results. It seems like the Smart Array controller is the bottleneck.

    Read the article

  • Upgrading disks in WD My Book Studio Edition II

    - by Bryan
    About 18 months ago, I purchased a 1Tb Western Digital My Book Studio Edition II for backup of my home system. It has 2x 500Gb drives in it, which I had configured as RAID 1. One of the disks has now died, and rather than replace like for like, I'd like to replace both drives to increase the capacity (2 x 2Tb would be nice). I'm struggling to find a list of compatible drives, has anyone else upgraded theirs?

    Read the article

  • HP Smart Array p400i with Intel X25-M 160 SSD

    - by user67304
    I have a pair of x25-M 160 Intel SSD's in an HP DL360 G5 with a p400i Smart Array running 512 BBWC. The disk performance I am getting on this box and another identical one does not come close to matching the same two drives running through a cheap 3ware RAID card. Any idea? I have played with the cache settings, but nothing allows me to get the same results. It seems like the Smart Array controller is the bottleneck.

    Read the article

  • How to Mount remote disc as local in Windows 7 and Windows 2003?

    - by Robert
    Is it possible to mount remote file system (on Windows 2003 server) as local disk in Windows 7? I have Windows 2003 server with software RAID and some shares. On another computer with Windows 7 I have software which can access only data form local or USB disks. This solution doesn't work because program doesn't see files in folder: Mount Remote CIFS/SMB Share as a Folder not a Drive Letter Everything is the same LAN.

    Read the article

  • How to recover ~1TB data from a bricked NAS?

    - by alastairs
    I bought an IcyBox NAS a little while back, and it recently died on me. I have physical access to the disks inside (1.5TB RAID 1 array), and the box was running a version of Linux. I now have the difficulty of retrieving the data from the disks. All I have available are 2 Windows machines, one of which has sufficient free space to hold the data from the NAS. What would be the quickest and easiest way to retrieve the data from the disks?

    Read the article

  • Well....a ghost lives in my server...

    - by tsgiannis
    Hello to every body and greetings from Greece I have a rather unusual situation and i am running out of ideas. I have this old server (IBM x205 - P4 2.4Ghz,3xSCSI 36gb) and i was about a year ago i decided to use it as an additional domain controller,fax & file server...for this task i had a Delock 70154 SATA card along with 2x320 SATA II HDDs Everything was going super smoothly until about 3 weeks ago. I was on a trip and i was informermed when i got back that the server was found frozen...well i considered it was a glitch since a simple powerdown power up fixed everything.Again 2 weeks ago another freeze situation....it got suspicious but again power down power up everything was running.... Last again it frozen and when i power it up it came with a message that the Domain services could not start due to NTDS corruption....booting in safe mode revealed that there was an issue with the SATA Raid (degraded). After a lot of searching i degraded the server...cleaned Active Directory and pulled both HDDs out (one of these was really BAD ) and recovered my files (i had some problems with ho Delock handles the redudant HDD). Right now my server is vanilla simple...with only what the factory installed and here is where the fun begins. Everyday when i arrive at the office i find this particular machine dead..and i mean total dead...just a black screen and nothing else...the cpu fan is working ,the psu is working .keyboard and mouse are dead(they also lock my kvm) ...network is dead.... the machine is DEAD. I power it down forcilly ...i power it up and for the 8 hours i am in the office it works,either idling or running some kind of diagnostic...when i leave the office after some time..it maybe half an hour ...it maybe 4 hours the machine dies...at least this is the information the event log shows (" the previous shutdown at xx:xx:xx was unexpected) Well i must admit i am runnig out of ideas.... I have tried Memtest....nothing Passmark burn in test.....nothing Carefull study of the event log.....nothing Set Instead of restart..BSOD....nothing Power sceheme to sleep...all set to never. i know there are a lot of other tools that heavily stress a machine like occt but .... the machine is old...today i will give them a try nevertheless ..... One idea is to reformat it...but ... i really like to find what is causing this because i could get to a situation that everything is working for a while and kaboom...one day again is dying.. I really need a helping hand and every opinion / idea is well welcomed.... iknow the obvious solution is to never leave the office but....i have a life...sory server...:) P.S this situation with the machine dying some time after is going on for about one week...everyday i would set either the RAID to rebuild....or to copy/recover files and while everythig was working

    Read the article

  • Connecting two servers together - How to?

    - by Chris
    Is it possible to connect two servers running for example Windows Server 2003/2008 together. For example they are seen on the network as one server with the combination of all HDD from each server? Example: \\Server1 - 1 x 1tb hdd \\Server2 - 1 x 1tb hdd I would like users of the network to be able to store their documents on both servers for load balancing. So basically a RAID between the two servers? Any help would be appreciated.

    Read the article

  • centos freezes with this error kernel: ata1.00: exception Emask 0x0 SAct 0x7fffffff SErr 0x0 action 0x0

    - by lakshman
    0 down vote favorite share [fb] share [tw] I am using centOs 5.5 version with raid 1 configuration the server freezes and goes to non response . the only thing i found on messages file is kernel: ata1.00: exception Emask 0x0 SAct 0x7fffffff SErr 0x0 action 0x0 The server is built recently Please let us know what is the problem the hard disk details are Model Number: ST500NM0011 Serial Number: Z1M02LT7 Firmware Revision: SN02

    Read the article

  • My Jtable is blank

    - by mazin
    Hello my q is about a jtable that i have ,i fill it with components from a .txt ,I have a main (menu ) JFrame and by pressing a jbutton i want the jtable to pop out ! My problem is that my jtable is blank and it supposed to show some date !I would appreciated any help , Thanks. this is my ''reading'' class` public static void main(String[] args) { company Company=new company(); payFrame jframe=new payFrame(Company); jframe.setDefaultCloseOperation( JFrame.EXIT_ON_CLOSE); jframe.setSize(600,300); jframe.setVisible(true); readClass(); } //diavasma public static void readClass(){ ArrayList<Employee> emp =new ArrayList<Employee>() ; //Employee[] emp=new Employee[7]; //read from file try { int i=0; // int rowCounter; // int payments=0; String inputDocument = ("src/Employees.txt"); FileInputStream is = new FileInputStream(inputDocument); Reader iD = new InputStreamReader(is); BufferedReader buf = new BufferedReader(iD); String inputLine; while ((inputLine = buf.readLine()) != null) { String[] lineParts = inputLine.split(","); String email = (lineParts[7]); int EmpNo = Integer.parseInt(lineParts[0]); String type = lineParts[10]; int PostalCode = Integer.parseInt(lineParts[5]); int phone = Integer.parseInt(lineParts[6]); int DeptNo = (short) Integer.parseInt(lineParts[8]); double Salary; int card = (short) Integer.parseInt(lineParts[10]); int emptype = 0; int hours=Integer.parseInt(lineParts[11]); if (type.equals("FULL TIME")) { emptype = 1; } else if (type.equals("SELLER")) { emptype = 2; } else { emptype = 3; } /** * Creates employee instances depending on their type of employment * (fulltime=1, salesman=2, parttime=3) */ switch (emptype) { case 1: Salary = Double.parseDouble(lineParts[10]); emp.add(new FullTime(lineParts[1], lineParts[2], EmpNo, lineParts[3], lineParts[4], PostalCode, phone, email, DeptNo, card, Salary,hours, type)); i++; break; and this is my class where i make my Jtable and fill him public class company extends JFrame { private ArrayList<Employee> emp = new ArrayList<Employee>(); public void addEmployee(Employee emplo) { emp.add(emplo); } public ArrayList<Employee> getArray() { return emp; } public void getOption1() { ArrayList<Employee> employee = getArray(); JTable table = new JTable(); DefaultTableModel model = new DefaultTableModel(); table.setModel(model); model.setColumnIdentifiers(new String[]{"Code", "First Name", "Last Name", "Address", "City", "Postal Code", "Phone", "Email", "Dept Code", "Salary", "Time Card", "Hours"}); for (Employee current : employee) { model.addRow(new Object[]{current.getempCode(), current.getfirst(), current.getlast(), current.getaddress(), current.getcity(), current.getpostalCode(), current.gettelephone(), current.getemail(), current.getdep(), current.getsalary(), current.getcardcode(), current.getHours() }); } table.setPreferredScrollableViewportSize(new Dimension(500, 50)); table.setFillsViewportHeight(true); JScrollPane scrollPane = new JScrollPane(table); add(scrollPane); setVisible(true); table.revalidate();

    Read the article

  • Which server would you purchase? IBM x3550 or Dell R610?

    - by Harry
    I'm in the market for a single unit rack mounted server with a strong upgrade pathway. The two servers on the top of my wish list are: IBM x3550 M2 Express Followed by Dell R610 Ultimately I want to have a Dual Quad Xeon (2 Ghz+) server with loads of RAM for a top notch DB server. The database is likely to keep growing indefinitly so a snappy Raid 5 array of Harddrives will be essential. Which would you purchase?

    Read the article

  • Program to swap files between drives?

    - by josi
    Has anyone built a program/script to transfer files between 2 hard drives, but like if both are near full....so one copies 1 file over then the other copies the other file, then they delete the files that were copied? Kind of annoying, have a 6tb raid at about 4tb full, then 1 4.5tb basically full, can't really swap them easily....without doing many copies and deletes of files.... Anyone know a way to make them just swap? lol

    Read the article

  • Windows 7 F6 Drivers off a USB Drive

    - by altCognito
    I'm doing a fresh install of Windows 7 and I have an on board software RAID. I "need" to install the drivers via the infamous F6 process. Technically, it should be possible to do so after the OS has been booted, but long story short, this isn't going to work well for me. Is it possible to install F6 drivers during the installation using a USB, or must that always be done using floppies? What are my alternatives?

    Read the article