Search Results

Search found 5429 results on 218 pages for 'smart pointers'.

Page 159/218 | < Previous Page | 155 156 157 158 159 160 161 162 163 164 165 166  | Next Page >

  • How to diagnose disk errors when disk appears to be ok?

    - by Kylotan
    I have a six-month-old 1TB Seagate drive formatted into 2 NTFS partitions, and the disk appeared to be failing with Windows dropping down from UDMA to PIO mode, reporting Delayed Write Errors, and hanging Explorer when browsing directories. My initial suspicion was that the disk was dying. However, on further examination it appears that Ubuntu, which doesn't write to the volume frequently like Windows does, was able to read the disk properly and retrieve all the data intact, saving me from having to use an older backup. Finally, running the Seatools DOS diagnostic reported that the disk has no problems, ie. SMART errors and no bad sectors, apparently. This, in combination with the relative youth of the disk, suggests that something else is broken. The cable? The PSU? The integrated disk controller? But what would be a good way to diagnose the problem without risking damaging the data? I intend to extract the disk and try it in an external eSATA enclosure and see if the write errors cease, but in the event of the disk appearing to be fine, I would like to be able to confirm what part of the hardware is actually broken here in order to know just what needs replacing. Are there any good ways to go about this?

    Read the article

  • Tomcat 7 on Ubuntu 12.04 startup issues

    - by Nico Huysamen
    I am having trouble getting tomcat 7 to start up on my new VPS. I am really scratching my head since I have done this often. So I'm thinking it might be the VPS. I just got a new VPS from CINFU. After a clean install of Ubuntu 12.04 32bit, I install openjdk-6-jdk, update JAVA_HOME to point to: /usr/lib/jvm/java-1.6.0-openjdk-i386 and JRE_HOME to: /usr/lib/jvm/java-1.6.0-openjdk-i386/jre But when I try to run: ./catalina.sh run it simply outputs: Using CATALINA_BASE: /opt/tomcat/apache-tomcat-7.0.29 Using CATALINA_HOME: /opt/tomcat/apache-tomcat-7.0.29 Using CATALINA_TMPDIR: /opt/tomcat/apache-tomcat-7.0.29/temp Using JRE_HOME: /usr/lib/jvm/java-1.6.0-openjdk-i386 Using CLASSPATH: /opt/tomcat/apache-tomcat-7.0.29/bin/bootstrap.jar:/opt/tomcat/apache-tomcat-7.0.29/bin/tomcat-juli.jar and stops. It just hangs there doing nothing. If I run ./startup.sh && tail -f ../logs/catalina.out it gets to: Aug 24, 2012 8:38:36 PM org.apache.coyote.AbstractProtocol init INFO: Initializing ProtocolHandler ["http-bio-8080"] Aug 24, 2012 8:38:36 PM org.apache.coyote.AbstractProtocol init INFO: Initializing ProtocolHandler ["ajp-bio-8009"] Aug 24, 2012 8:38:36 PM org.apache.catalina.startup.Catalina load INFO: Initialization processed in 495 ms Aug 24, 2012 8:38:36 PM org.apache.catalina.core.StandardService startInternal INFO: Starting service Catalina Aug 24, 2012 8:38:36 PM org.apache.catalina.core.StandardEngine startInternal INFO: Starting Servlet Engine: Apache Tomcat/7.0.29 but I am unable to access anything. The request just hangs. I have also tried a few other things like explicitly exporting the paths etc in catalina.sh, and running ./startup.sh rather than catalina.sh, but the furthest I have gotten is that it finishes deploying all the WARs (the default ones that comes with tomcat like the host-manager etc), but then it hangs: Aug 24, 2012 8:47:30 PM org.apache.coyote.AbstractProtocol init INFO: Initializing ProtocolHandler ["http-bio-8080"] and does nothing. Anyone have any pointers that might help? As I said, I must really be missing something stupid since this has worked on all other VPSs that we have. UPDATE I figured out that the problem is actually the fact that they use OpnVZ virtualization and that there are known compatibility problems with Java.

    Read the article

  • COM+/Desktop Heap errors in IIS affecting sites at random?

    - by tresstylez
    We have a Win2K3 server that is hosting 30+ sites. Each site is configured to have its own unique application pool -- so that we can manually recycle specific sites if needed and not kill sessions for the others. From what I've read, the consequence of this type of setup is that each application pool worker process gets allocated a Desktop Heap (normally 512 kb's) and we limit the number of app pools we can serve. http://blogs.msdn.com/b/david.wang/archive/2006/01/25/security-considerations-of-usesharedwpdesktop-on-iis6.aspx PROBLEM: What we're seeing is that occasionally COM+ errors get triggered, presumably by hitting our 512 kb limit of the desktop heap -- and certain sites become unresponsive (or have errors) until we manually recycle that specific app pool. I know that I can increase the desktop heap limit to 1024, and make other tweaks/tunes, but I've been tasked with finding out what exactly causes one site's heap to max out as opposed to another. It seems that when we start seeing COM+ errors, the sites it affects are random -- small sites or big sites (heavier used). Is it based on process id? Traffic? Any pointers on understanding this a little more would be excellent. Thanks! jg

    Read the article

  • ESXi Server with 12 physical cores maxed out with only 8 cores assigned in virtual machines

    - by Sam
    I have an ESXi 5 server running on a 2-processor, 12-core system with hyperthreading enabled. So: 12 physical cores, 24 logical ones. On this server are 4 Windows 7 VMs, each configured for 2 processors, each running VMware Tools. Looking at my stats in vSphere, my "core utilization" is constantly maxed out. Yes, these machines are working hard, but only 8 cores have been allocated. How is this possible? Should I look into reducing the processor count per machine as in this post: VMware ESX server? I checked to ensure that hardware virtualization is enabled in the BIOS of the machine (a DELL R410). I've also started reading up on configuration, but being a newbie there's a lot of material to catch up on. It also seems I should only bother with advanced settings and pools if I'm really pushing the load, and I don't think that I should be pushing it with so few VMs. I suspect that I have some basic, incorrect configuration setting, but it's also possible that I have some giant misconceptions about virtualization. Any pointers? EDIT: Given the responses I've gotten so far, it seems that this is a measurement problem and not a configuration problem, making this less critical. Perhaps the real question is: How does the core utilization of the server reach a higher percentage than all individual cores' core utilization, and given that this possibility makes the metric useless for overall server load, what is the best global metric for measuring CPU load on hyper-threaded systems?

    Read the article

  • BitLocker with Windows DPAPI Encryption Key Management

    - by bigmac
    We have a need to enforce resting encryption on an iSCSI LUN that is accessible from within a Hyper-V virtual machine. We have implementing a working solution using BitLocker, using Windows Server 2012 on a Hyper-V Virtual Server which has iSCSI access to a LUN on our SAN. We were able to successfully do this by using the "floppy disk key storage" hack as defined in THIS POST. However, this method seems "hokey" to me. In my continued research, I found out that the Amazon Corporate IT team published a WHITEPAPER that outlined exactly what I was looking for in a more elegant solution, without the "floppy disk hack". On page 7 of this white paper, they state that they implemented Windows DPAPI Encryption Key Management to securely manage their BitLocker keys. This is exactly what I am looking to do, but they stated that they had to write a script to do this, yet they don't provide the script or even any pointers on how to create one. Does anyone have details on how to create a "script in conjunction with a service and a key-store file protected by the server’s machine account DPAPI key" (as they state in the whitepaper) to manage and auto-unlock BitLocker volumes? Any advice is appreciated.

    Read the article

  • bind9 "error sending response: host unreachable"

    - by wolfgangsz
    of course), I have a number of DNS servers, all running bind9 (9.5.1, to be specific) under fedora. 4 of them are slaves, fed by a common master for our public DNS. These are all located on the public gateways of our various offices. One of them has tons of messages in its log files similar to these: Jul 21 17:26:18 gateway named[3487]: client 10.171.3.8#52500: view internal: error sending response: host unreachable I wonder where that comes from. The firewall is open on port 53 between the two machines (10.171.3.8 is an internal DNS server located on a Windows Domain Controller). The internal domains do NOT list the gateway as a name server (so there should not be any attempts of replicating the domains), and the gateway does not handle any internal DNS. The clients in these messages vary between the two domain controllers on the internal network and a third internal name server (running bind9 on debian in a different segment of the network). Any pointers are highly welcome. In response to the first reply: The issue with this really is that tcpdump doesn't show any problems. Here is an extract from "tcpdump -i any port 53" 09:13:38.283308 IP valine.aminocom.com.61815 ns-pri.ripe.net.domain: 14075 PTR? 166.225.58.95.in-addr.arpa. (44) 09:13:42.007410 IP gateway-eng.aminocom.com.37047 alanine.aminocom.com.domain: 35410+ PTR? 12.3.172.10.in-addr.arpa. (42) At the same time, the DNS log shows: Jul 22 09:13:38 gateway named[3487]: client 10.171.3.6#61300: view internal: error sending response: host unreachable Jul 22 09:13:40 gateway named[3487]: client 10.172.3.12#56230: view internal: error sending response: host unreachable Jul 22 09:13:40 gateway named[3487]: client 10.171.3.8#55221: view internal: error sending response: host unreachable Jul 22 09:13:49 gateway named[3487]: client 10.171.3.8#51342: view internal: error sending response: host unreachable So clearly at 09:13:40 there were two unsuccessful attempts to connect to internal machines (10.172.3.12 and 10.171.3.8, both are DNS servers), but nothing in the tcpdump output.

    Read the article

  • switchless Infiniband between two servers on RHEL 6.3

    - by exfizik
    I have 2 servers running RHEL 6.3 which have 2 port Infiniband cards >lspci | grep -i infini 07:00.0 InfiniBand: QLogic Corp. IBA7322 QDR InfiniBand HCA (rev 02) I'm interested in connecting them directly to each other bypassing an Infiniband switch (which I don't have). Quick googling showed that at least in some configurations it's possible. I installed all RedHat Infiniband packages with yum groupinstall "Infiniband Support". However, ibv_devinfo shows that both ports in each card are down, which indicates that cables are not connected. But the cable is connected, although the LEDs are off on the cards (not a good sign). Another source of confusion for me is that according to this, RedHat doesn't come with OFED packages and I'm slightly hesitant to install them from source due to the lack of RedHat support for them... So where am I going with this? The questions I have are: is it possible to have a switchless/direct Infiniband connection between two servers the way I described above? If it's possible, do I have to use the OFED packages or can I configure everything with just the packages coming with RHEL. Why are the LEDs off on my servers even though the cable is connected? Any additional input/advice/pointers would be appreciated. P.S. I followed this guide for installation instructions. The Infiniband cards are clearly recognized by my OS and the rdma service is running. Update: I have opensm installed. When I run it it says: OpenSM 3.3.13 Command Line Arguments: Log File: /var/log/opensm.log ------------------------------------------------- OpenSM 3.3.13 Entering DISCOVERING state Using default GUID 0x1175000076e4c8 SM port is down and stays at that point.

    Read the article

  • Clicking a link in IE6 doesn't load page (internal DNS entry on our intranet)

    - by Callum
    I have a very strange problem that is only affecting some versions of IE6. The problem does affect IE 6.0.2900.5512, but does not seem to affect 6.0.3790.3959 Basically I work for a company and we have an intranet. While I'm not an expert on "internal DNS pointers", what I was able to do was create a website (let's say about football), and when an employee who is sitting behind the company firewall types the word "football" in to the web address bar of their web browser, they get redirected to a particular server. I am told this is some kind "internally pointing DNS entry". So, I've set one of these up, and I have a placed a link to it on our company intranet page. However, when the link is clicked in IE6.0.2900.5512, the page goes blank. Clicking "refresh" then loads the correct page (the one specified in the link). Can anyone help me out here. I have tried changing the way URL is formed, everything from //football to http://football/ etc. The link works fine in every other browser and IE7+, but unfoturnatly, IE6 is still the most common browser in use at my organisation.

    Read the article

  • Secure iptables config for Samba

    - by Eric
    I'm trying to setup an iptables config such that outbound connections from my CentOS 6.2 server are allowed ONLY if they are of state ESTABLISHED. Currently, the following setup is working great for sshd, but all the Samba rules get totally ignored for a reason I cannot figure out. iptables Bash script to setup ALL rules: # Remove all existing rules iptables -F # Set default chain policies iptables -P INPUT DROP iptables -P FORWARD DROP iptables -P OUTPUT DROP # Allow incoming SSH iptables -A INPUT -i eth0 -p tcp --dport 22222 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --sport 22222 -m state --state ESTABLISHED -j ACCEPT # Allow incoming Samba iptables -A INPUT -i eth0 -s 10.1.1.0/24 -p udp --dport 137:138 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -d 10.1.1.0/24 -p udp --sport 137:138 -m state --state ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -s 10.1.1.0/24 -p tcp --dport 139 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -d 10.1.1.0/24 -p tcp --sport 139 -m state --state ESTABLISHED -j ACCEPT # Enable these rules service iptables restart iptables rule list after running the above script: [root@repoman ~]# iptables -L Chain INPUT (policy DROP) target prot opt source destination ACCEPT tcp -- anywhere anywhere tcp dpt:22222 state NEW,ESTABLISHED Chain FORWARD (policy DROP) target prot opt source destination Chain OUTPUT (policy DROP) target prot opt source destination ACCEPT tcp -- anywhere anywhere tcp spt:22222 state ESTABLISHED Ultimately, I'm trying to restrict Samba the same way I have done for sshd. In addition, I'm trying to restrict connections to the following IP address range: 10.1.1.12 - 10.1.1.19 Can you guys offer some pointers or possibly even a full-blown solution? I've read man iptables quite extensively, so I'm not sure why the Samba rules are getting thrown out. Additionally, removing the -s 10.1.1.0/24 flags don't change the fact the rules get ignored.

    Read the article

  • How do you get Windows 7 to show time remaining in the battery meter?

    - by MrDaniel
    Running Microsoft Windows 7 Home Premium on a HP Laptop. The system tray power meter never shows the time remaining in the system tray. Only really ever show a percentage remaining number as pictured. The windows help documentation on the "battery meter" seems to indicate that it should display a time remaining indicator, is this accurate? How accurate is the battery meter? The accuracy of what the battery meter reports—what percentage of a full charge remains and how long you can use your laptop before you must plug it in—depends on several factors. Most of these factors fall into the following two categories: What you use the laptop for. Because some activities drain the battery faster than others (for example, watching a DVD consumes more power than reading and writing e-mail), alternating between activities that have significantly different power requirements changes the rate at which your laptop uses battery power. This can vary the estimate of how much battery charge remains. Battery hardware and sensor circuitry. Newer, "smart" batteries are equipped with circuitry that calculates the measurements of charge remaining and reports the information to the battery meter. Older batteries use less sophisticated circuitry and might be less accurate.

    Read the article

  • My hard drive seems to be overheating... what should I do?

    - by George Edison
    After a cold boot, the hard drive in my notebook jumps to 56? within an hour or so of idling. Is 56? a cause for alarm? Notes: The notebook is on a flat desk and none of the vents are obstructed. The video card is currently at 55? and the CPU at 50?. It's a Western Digital 250GB hard drive. SMART reports the drive healthy but does warn that: Edit: this problem had a very surprise ending. I inverted the notebook and unscrewed some of the panels on the back (there was one covering the hard drive, and one that provided access to the memory). I couldn't see any dust, so I simply screwed everything back together and powered it on... and it worked! The temperature is now staying at 46?, and it feels notable cooler to the touch. So I can only assume that some internal fan was malfunctioning or something. Whatever the case, it's working now so I won't complain. Edit: I have an SSD now, so temperature isn't as big an issue as it was when I had a mechanical drive.

    Read the article

  • external drive enclosure -> software RAID 5?

    - by memilanuk
    Hello all, I have two older PCs on my LAN posing as 'servers'... one running FreeNAS off a USB stick using three 500GB hdds in a ZFS RAID-Z pool serving as storage for the LAN and one running Debian Lenny with an 80GB drive used as a general purpose 'tinker' box that I can ssh into, etc. Problem is that the SMART report for one of those 500GB drives in the FreeNAS box is showing some pre-failure attributes, and the whole array is a little small anyways. Rather than simply replace one 500GB drive with another 500GB drive, and have no backup of the file server, I'd like to upgrade all the drives to 2TB ones - but I have no where to store that much data in the mean while. As such, I started looking at getting a 4-bay external drive enclosure with an eSATA card for the Debian box, with the hopes of creating a RAID5 + LVM setup using those drives and backing the data up to that external drive enclosure. After the backup is done, replace the drives in the FreeNAS box and rebuild the array there and mirror the data back. Then, I'd have both the primary storage (on the FreeNAS box) and a backup (which I don't have currently) using the external drive enclosure on the Debian box. My big question is... most of these external drive boxes seem to claim support for JBOD, RAID 0, 1, 10, 5, etc. - should I presume that is simply fake RAID like many commodity mobos have, and not really usable in Linux? In that case, with all the drives hanging off the one eSATA connection, will Linux (specifically Debian Squeeze, as I plan on upgrading that box here shortly) see all four drives, or just the first one? Will I be able to configure them in a RAID5 array as desired? Thanks, Monte

    Read the article

  • Mail.app doesn't detect sender in Address Book

    - by CoreSandello
    Hi there. I don't understand, how does 'smart addresses' in Mail.app work. Recently I mentioned, that for some emails I don't see person's full name in 'From' column. I started to dig into this behavior and found out, that I have few contacts in my Address Book, that are not recognized by Mail.app. Here how it looks: I have a person in Address Book with filled email entry and filled first/last name (localized). I have an incoming email from that person (from email specified in Address Book), but first/last name in the email itself doesn't match with ones specified in Address Book (e. g. 'From' field in email looks like 'John [work] <[email protected]>' while Address Book entry is 'John Smith' (localized, in Russian)). And Mail.app doesn't recognize that this mail is originating from that person in Address Book: if I click on 'From' field, it suggests to me to add sender to Address Book, while for others' emails I have 'Show in Address Book' menu entry (especially for ones with full localized name in 'From' field). I'm wondering, is that behavior correct or I'm missing something? I'm using Snow Leopard & Mail 4.0; my system language set to English, if that matters. I'd like to have some clarifications on that Mail.app behavior: whenever it fixable or not (and if it's fixable, I'd like to see a fix). By the way, is it possible to match sender's address against Address Book entry in filter rules or not? That would be great, if I can create rules like 'move all mail from that person to that folder' without specifying exact source address. Thanks, Ivan.

    Read the article

  • how to split a very large database on sql server

    - by ken jackson
    I have a 90 GB SQL Server database that I want to make more manageable. It stores stock data from 50+ different stocks from 2009 and 2010, and each stock is a separate table. Some tables have hundreds of millions of rows, and other have just a few million. What I want to do is somehow split the database, so that I don't have a single database file that is 90 GB. What I want is to be able to somehow magically split all the tables so that I can backup the 2009 data once and not have to keep on including it in the backup every time I backup the entire database, however, I would like the 2009 data to be included whenever I do a query. Is partitioning the database the way to go? Will it do the above for me, or will I need some other solution? I research partitioning, but I wasn't sure if that would solve all my problems. I wasn't able to find anything that would tell me whether or not it would migrate prexisting data, or whether it only worked for newly inserted data. Any help or pointers would be much appreciated. Thanks in advance, Ken

    Read the article

  • configure apache/webdav readonly for user x, read/write for user y

    - by user82296
    I'm using Apache 2.2 on RHEL 6.x. I can get webdav setup as readonly for user x or readwrite for user x but can't figure out how to make it read only for user x and read/write for user y. I just have a single folder /var/www/html/davtest owned by apache:apache and I want myUser to have readonly access and myAdmin to have read/write access. So far I've only been able to control this by modifying the permissions on the dir /var/www/html/davtest (e.g. if apache has rw then no matter how I set limitExcept below either user can read/write Is this in general possible? <Directory /var/www/html/davtest > DAV on Options Indexes AuthType Digest AuthName myAuth AuthDigestDomain /myD/ http://mysys.x.y/davtest AuthDigestProvider file AuthUserFile /var/www/davDigest/dav_pw require user readOnlyUser <limitExcept get head options> require user myAdmin </limitExcept> </Directory> I've tried various permutations with Limit, LimitExcept and it appears that the only thing that determines who can read/write to the share are the permissions on the files/folders in the share. any guidance, pointers to docs would be greatly appreciated. thanks

    Read the article

  • Can IIS (Ideally Azure) do SSL Proxying?

    - by Acoustic
    My team has been asked to add a new feature to a project we're working on, and none of can find authoritative details on whether it's possible with Windows/IIS. The short of it is that we're hoping to have customers update their DNS with a CNAME record to point their website to our server instead of theirs (they why's are trivial - it's what the app does on behalf of your site). We're using a reverse proxy with several custom modules to serve particular content from the original servers. So far everything works perfectly until we encounter SSL. Is there a way to have IIS serve up an SSL certificate from another server? In other words, is there a way to be a trusted man in the middle? I'm hoping that's possible so that we don't have to require all our clients to re-issue their SSL certs. Frankly, we don't want to have to manage hundreds of certs. I'd also like to avoid a UCC situation if there's a way to because it seems to require re-creating the cert each time a client is added. So, any pointers on proxying/hosting SSL (or even dynamic SSL hosting like http://www.globalsign.com/cloud/) would be appreciated.

    Read the article

  • do not require smtp authentication for a specific domain using hMail server

    - by toryan
    One of my clients has a needlessly complex e-mail setup for a couple of domains, which is causing problems when they try to send e-mail between them. They have a couple of domains where mail follows a slightly weird path: Users connect to an Exchange server to send e-mail The exchange server relays the message to an ISP-owned SMTP server as a smart host The ISPs server delivers the mail to the mail exchanger specified in DNS The mail exchanger is another server that runs hMailServer The Exchange server connects to the hMail server via POP3 and retrieves the messages. The problem arises when they send mail between addresses in the same domain, or two addresses that are present on the hMail server. hMail requires SMTP authentication when sending from local to local addresses, so the messages don't arrive. Removing SMTP authentication isn't really an option, as the server has been the target of spam being sent from spoofed local addresses. SMTP authentication prevents this. It is possible to add the ISP's mail server as an IP range with specific rules, but this seems inelegant. Bearing in mind I only have access to the hMail server and not the Exchange server, is there a better way of going about this?

    Read the article

  • How to setup DNS server behind a VPN

    - by Brian
    I want to host some websites behind a VPN and I need some help with the finer points of the configuration. Thus far I've settled on OpenVPN + Bind9 and I want to configure the domains like this: External DNS mail.example.com www.example.com vpn.example.com I want to be able to connect to the vpn using 'vpn.example.com'. Once connected I then want to be able to resolve anything which is '*.vpn.example.com' with the DNS server sitting behind the VPN. I know that OpenVPN can push DNS servers to clients when they connect. I am having trouble though with the DNS config, both internal and external. I've gone through a few tutorials etc. and tried to reason about it myself but I'm not getting anywhere. So my main question would be does the above configuration make sense? If so, any general pointers or examples would be greatly appreciated. Here's what I've tried so far based on this tutorial (I've redacted my domain with example.com). When I try the tests with dig at the end to check the resolution is working it fails. db.vpn.example.com $TTL 15m vpn.example.com. IN SOA ns.vpn.example.com. [email protected]. ( 2009010910 ;serial 900 ;refresh 900 ;retry 900 ;expire 900 ;minimum TTL ) vpn.example.com. IN NS ns.vpn.example.com. ns IN A 192.168.0.2 test IN A 192.168.0.2

    Read the article

  • What are the advantages and disadvantages of the various virtual machine image formats?

    - by Matt
    Xen and Virtualbox etc both support a range of different virtual machine image formats. These are: vmdk, vdi, qcow & qcow2, hdd & vhd. Without any bias toward a particular product, I'm wanting to know what are the advantages and disadvantages of the various formats both from a features perspective, robustness and speed? One piece of info I discovered in a forum post was this: "The major difference is that VDI uses relatively large blocks (1MB) when growing an image, and thus has less overhead for block pointers etc. but isn't ultimately space efficient in the sense that if a single byte is non-zero in such a 1MB block the entire space is used. VMDK in contrast uses 64K blocks, and thus has more management overhead and generally a bit less disk space consumption What offsets this is that VDI is more efficient when it comes to snapshots." You might be thinking, I want to know this because I want to know which format to choose? Not exactly, I'm developing some software which utilises these formats and want to support one or more of them. Simplicity, large disks and ease of development are my main drivers.

    Read the article

  • F5 Networks iRule/Tcl - Escaping UNICODE 6-character escape sequences so they are processed as and r

    - by openid.malcolmgin.com
    We are trying to get an F5 BIG-IP LTM iRule working properly with SharePoint 2007 in an SSL termination role. This architecture offloads all of the SSL processing to the F5 and the F5 forwards interactive requests/responses to the SharePoint front end servers via HTTP only (over a secure network). For the purposes of this discussion, iRules are parsed by a Tcl interpretation engine on the F5 Networks BIG-IP device. As such, the F5 does two things to traffic passing through it: Redirects any request to port 80 (HTTP) to port 443 (HTTPS) through HTTP 302 redirects and URL rewriting. Rewrites any response to the browser to selectively rewrite URLs embedded within the HTML so that they go to port 443 (HTTPS). This prevents the 302 redirects from breaking DHTML generated by SharePoint. We've got part 1 working fine. The main problem with part 2 is that in the response rewrite because of XML namespaces and other similar issues, not ALL matches for "http:" can be changed to "https:". Some have to remain "http:". Additionally, some of the "http:" URLs are difficult in that they live in SharePoint-generated JavaScript and their slashes (i.e. "/") are actually represented in the HTML by the UNICODE 6-character string, "\u002f". For example, in the case of these tricky ones, the literal string in the outgoing HTML is: http:\u002f\u002fservername.company.com\u002f And should be changed to: https:\u002f\u002fservername.company.com\u002f Currently we can't even figure out how to get a match in a search/replace expression on these UNICODE sequence string literals. It seems that no matter how we slice it, the Tcl interpreter is interpreting the "\u002f" string into the "/" translation before it does anything else. We've tried various combinations of Tcl escaping methods we know about (mainly double-quotes and using an extra "\" to escape the "\" in the UNICODE string) but are looking for more methods, preferably ones that work. Does anyone have any ideas or any pointers to where we can effectively self-educate about this? Thanks very much in advance.

    Read the article

  • Plesk 10 - creating and using vhost.conf

    - by MrFidge
    I'm having some issues setting up and using a vhost.conf for one of my domains. So far none of the domains have required any extra configuration but now I need to use a PEAR module, so I'm looking to include /usr/share/pear in the PHP settings for the domain. vhost file created in /var/www/vhosts/domain.com/conf/vhost.conf <Directory /var/www/vhosts/domain.com/httpdocs> php_admin_value include_path ".:/usr/share/pear" </Directory> I then restart Plesk using: /usr/local/psa/admin/sbin/websrvmng --reconfigure-vhost --vhost-name=domain.com Or as plesk says that command is obsolete in Plesk 10 I've tried using /usr/local/psa/admin/sbin/httpdmng --reconfigure-domain domain.com And for good luck I've restarted apache too each time. Net result - none of the PEAR includes work unless I edit the include_path in /etc/php.ini! Any tips on how to get this MOFO working? I've had a look through the documentation but TBH I just don't have time to read 40 pages of Plesk manual for one line of code, this can't be that hard, surely! Thanks for any pointers, H

    Read the article

  • What would keep a Microsoft Word AutoNew() macro from running?

    - by Chris Nelson
    I'm using Microsoft Office 2003 and creating a bunch of template documents to standardize some tasks. I know it's standard practice to put the templates in an certain place Office expects to find them but that won't work for me. What I want is to have "My Template Foo.dot" and "My Template Bar.dot", etc. in the "My Foo Bar Stuff" on a shared drive and users will double click on the template to create a new Foo or Bar. What's I'd really like is for the user to double click on the Foo template and be prompted for a couple of items related to their task (e.g., a project number) and have a script in the template change the name that Save will default to something like "Foo for Project 1234.doc". I asked on Google Groups and got an answer that worked....for a while. Then my AutoNew macro stopped kicking in when I created a new document by double clicking on the template. I have no idea why or how to debug it. I'm a software engineering with 25+ years of experience but a complete Office automation noob. Specific solutions and pointers to "this is how to automate Word" FAQs are welcome. Thanks.

    Read the article

  • Hard Disk:S.M.A.R.T. Stas BAD, Back up and replace

    - by Nick
    I have an laptop top hard drive I was trying to use to my new media computer. The case is small and can accommodate for 2 2.5" drives, no 3.5" drives. I had been using the hard drive as storage hard drive until now. When I go to install Windows on the hard drive first I'm prompted at the bios of: Hard Disk:S.M.A.R.T. Stas BAD, Back up and replace. And then again in the Windows Setup, informing me that the hard drive is bad. So I did a full format of the drive and tried again. Same error. So I took it out and hooked it back up to my other computer via an Sata usb adapter kit (maybe the cause?). The hard drive is recognized fine and when I scanned it for errors by going: right click -> properties -> tools -> error checking It returns that the hard drive is fine. I have tried 3 different SATA cables and multiple jumpers. When I plugged in my 1.5 tb 3.5" drive the computer that gives me the S.M.A.R.T. error on the 2.5" drive, recognizes it with no problems. Any ideas on why this is happening and how I can fix it?

    Read the article

  • Joining Samba to Active Directory with local user authentication

    - by Ansel Pol
    I apologise that this is somewhat incoherent, but hopefully someone will be able to make enough sense of this to understand what I'm trying to achieve and provide pointers. I have a machine with two network interfaces connected to two different networks (one of which it's providing several other services for, such as DNS), running two separate instances of Samba, one bound to each interface. One of the instances is just a workgroup-style setup using share-level authentication, which is all working fine. The problem is that I'm looking to join the other instance to an MS Active Directory domain (provided by MS Windows Small Business Server 2003) to enable a subset of the domain users to access the shares from Windows machines on the other network. The users who need access from the domain environment have accounts (whose names are all-lowercase versions of their domain usernames) on the machine running Samba, but I'm not sure about how to map the UIDs and everything I've read concerns authenticating accounts on that machine against either AD or another LDAP server. To clarify: I only want the credentials for AD users accessing the non-workgroup Samba instance to be authenticated against AD, not the accounts on the machine running Samba. I hope this is sufficiently clear. EDIT: In addition to being able to access the Samba shares from AD, I do also need to be able to access a share on the domain from the machine running Samba but would still like everything non-Samba-related to authenticate locally.

    Read the article

  • UPS with a HP Proliant server

    - by Groo
    We placed a EATON Ellipse Max 1500 (900W) as the UPS for our HP Proliant ML350 G6. Upon first power failure (actually we only moved the UPS' input plug to a different socket), server immediatelly turned off, and the Health LED turned red and started blinking. UPS was in operation for about a week before that, with battery fully charged to 100%. Since our server's hot-plug supply is 460W, we are pretty sure we haven't overloaded it, the server was completely idle at that time (no web or win apps running except Windows Server core services). Then we tried to do the same with a different, no-name older PC (Core 2 Duo, 2Gb RAM) with a generic power supply (not sure what the power is) and it continued working when we pulled the plug out. UPS load was less than 15% (measured in the provided Eaton utility). We measured the UPS' output voltage using a smart oscilloscope and the THD of the UPS output waveform turned out to be 40%. Did you have similar experiences? Could this be a faulty UPS? Or a faulty power supply? Or some HP sensors configured to trigger too strictly? I wouldn't like replacing this UPS with the same brand, to get same results. [Edit] I also tried to do this while the server is turned off. While the UPS is working on battery, server will not start - as soon as I press the power button, Health LED starts blinking red.

    Read the article

< Previous Page | 155 156 157 158 159 160 161 162 163 164 165 166  | Next Page >