Search Results

Search found 18132 results on 726 pages for 'connection timeout'.

Page 16/726 | < Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >

  • HttpURLConnection timeout question

    - by Malachi
    I want to return false if the URL takes more then 5 seconds to connect - how is this possible using java? Here is the code I am using to check if the URL is valid HttpURLConnection.setFollowRedirects(false); HttpURLConnection con = (HttpURLConnection) new URL(url).openConnection(); con.setRequestMethod("HEAD"); return (con.getResponseCode() == HttpURLConnection.HTTP_OK);

    Read the article

  • Does Safari have a timeout issue?

    - by woodysapsucker
    I have a website that works fine in Firefox and IE but never finishes loading in Safari 4.0.4. The live website loads a menu then loads a Google map. Using Safari, the Google map never loads. I have a test website on the same server that uses the exact same code for loading a Google map and Safari can load the map (this is the one that won't load on my live web). This test website does not have the menu - only the Google map. In both cases (live and test) the main web page calls a loadmap.js file. I've been pulling everything apart to try to identify why Safari won't finish loading. Has anyone run across any problems/solutions with Safari that may help me find a resolution to this problem?

    Read the article

  • Jquery timeout on each

    - by pingu
    Hi guys, I'm trying to write a jQuery function to change out href of a link, but I'm not quite sure how to do it. I've implemented a slider, but I have a link which lives outside of the slider (outsideLink) which needs to change as the slider changes. I'm trying to achieve the following: for each link in sliderList get currentLink.href outsideLink.href = currentLink.href wait 3 seconds repeat end I'm not sure how to implement the delay when I'm going through a list of items though.

    Read the article

  • ASP.NET Webforms site using HTTPCookie with 100 year timeout times out after 20 minutes

    - by Rob
    I have a site that is using Forms Auth. The client does not want the site session to expire at all for users. In the login page codebehind, the following code is used: // user passed validation FormsAuthentication.Initialize(); // grab the user's roles out of the database String strRole = AssignRoles(UserName.Text); // creates forms auth ticket with expiration date of 100 years from now and make it persistent FormsAuthenticationTicket fat = new FormsAuthenticationTicket(1, UserName.Text, DateTime.Now, DateTime.Now.AddYears(100), true, strRole, FormsAuthentication.FormsCookiePath); // create a cookie and throw the ticket in there, set expiration date to 100 years from now HttpCookie cookie = new HttpCookie(FormsAuthentication.FormsCookieName, FormsAuthentication.Encrypt(fat)) { Expires = DateTime.Now.AddYears(100) }; // add the cookie to the response queue Response.Cookies.Add(cookie); Response.Redirect(FormsAuthentication.GetRedirectUrl(UserName.Text, false)); The web.config file auth section looks like this: <authentication mode="Forms"> <forms name="APLOnlineCompliance" loginUrl="~/Login.aspx" defaultUrl="~/Course/CourseViewer.aspx" /> </authentication> When I log into the site I do see the cookie correctly being sent to the browser and passed back up: However, when I walk away for 20 minutes or so, come back and try to do anything on the site, the login window reappears. This solution was working for a while on our servers - now it's back. The problem doesn't occur on my local dev box running Cassini in VS2008. Any ideas on how to fix this?

    Read the article

  • PHP & MySQLi timeout

    - by Dt7
    Whenever I try to create a mysqli object, as in; $mysqli = new mysqli(host, user, pass, table); ...the page just loads for around a minute, then stops, showing all the content of the page up until that line. info() says that MySQLi (and MySQL if that matters) are enabled, and I can access the MySQL CLI. I'm also working on a local machine, not a remote server. I feel like I've missed something obvious. Can anyone shed some light on it? Edit: just for clarification, I am actually putting real values into the mysqli constructor :)

    Read the article

  • "ssh_exchange_identification: Connection closed by remote host lost connection" when running cron job

    - by grautur
    I have a Ruby script that connects to a remote machine via ssh and executes a command. The script runs fine when I just run it in my terminal. In my crontab, I have 1 * * * * /bin/bash -l -c 'ruby myfile.rb' and if I go ahead and run /bin/bash -l -c 'ruby myfile.rb', everything executes fine. But when cron itself executes the job, I get a ssh_exchange_identification: Connection closed by remote host error. What's the cause of this? How do I fix it?

    Read the article

  • Jquery delay timeout function???

    - by iSimpleDesign
    I am really struglling tring to get this to work what i what is if my php script returns success. echo success I want it to should a message that says congratulations its all setup but stay for aleast 5 seconds but it never seems to work i have tried elay etc but still getting issues please help. here is my code it works but for about a second it then redirects far to quick to read it. if($.trim(data) == 'Congratulations'){ setTimeout(function(){ $('#congrats').fadeIn(1000,function(){ window.location.href='http://example.co.uk/tour/first-time-users'; }); },5500);

    Read the article

  • Mysql refusing connection: a very special connection issue

    - by k to the z
    I have my programers remoting into a web server with windows rdp. This web server is the only machine that can access another mysql server in a secure zone. When I remote into the web server from my machine I am able to connect to the mysql server through the mysql workbench on the web server. However, when I try this same procedure from another person's computer I can get into the server via rdp. I just can't connect to mysql using the workbench. I have checked and re checked the credentials and connection information. They match. I've had other people check and re check the credentials. As far as mysql permissions are concerned this user is allowed to connect from any machine. Plus I'm remoting into the same web server. The only difference seems to be which computer is remoting into the webserver. wtf?

    Read the article

  • connection to apache server switches sockets connection

    - by Newben
    I have just post a question but I post an other one because the problem is not the one I had in thought when asking the latter. So, I am running some rails app on osx, when I run rails s, everything works fine. If I shut down the apache server (mamp) and if I run rails s again, I have this message Can't connect to local MySQL server through socket '/Applications/MAMP/tmp/mysql/mysql.sock', which for sure is normal. For info, my mamp server is running, and the connection must pass through /Applications/MAMP/Library/bin/mysql, so I aliased it by setting in my bash profile : alias mysql="/Applications/MAMP/Library/bin/mysql" Now, when I launch a rails generate command type, I get this message : /$root/vendor/bundle/ruby/2.0.0/gems/mysql2-0.3.11/lib/mysql2/client.rb:44:in `connect': Can't connect to local MySQL server through socket '/tmp/mysql.sock' (2) (Mysql2::Error) So how it can be ?

    Read the article

  • Unable to access certain websites from a computer

    - by matt74tm
    One of the desktop computers in my office is unable to access some particular websites. We've tried from Chrome, IE, Firefox, but no luck. eg: http://spsims.wto.org/ -> click on "Regular notifications" On the affected computer, every browser times out after the click. Whereas it should redirect the user to http://spsims.wto.org/web/pages/search/notification/regular/Search.aspx How can I diagnose this further? This is a Windows XP machine.

    Read the article

  • Configuration setting of HttpWebRequest.Timeout value

    - by Michael Freidgeim
    I wanted to set in configuration on client HttpWebRequest.Timeout.I was surprised, that MS doesn’t provide it as a part of .Net configuration.(Answer in http://forums.silverlight.net/post/77818.aspx thread: “Unfortunately specifying the timeout is not supported in current version. We may support it in the future release.”) I added it to appSettings section of app.config and read it in the method of My HttpWebRequestHelper class  //The Method property can be set to any of the HTTP 1.1 protocol verbs: GET, HEAD, POST, PUT, DELETE, TRACE, or OPTIONS.        public static HttpWebRequest PrepareWebRequest(string sUrl, string Method, CookieContainer cntnrCookies)        {            HttpWebRequest webRequest = WebRequest.Create(sUrl) as HttpWebRequest;            webRequest.Method = Method;            webRequest.ContentType = "application/x-www-form-urlencoded";            webRequest.CookieContainer = cntnrCookies; webRequest.Timeout = ConfigurationExtensions.GetAppSetting("HttpWebRequest.Timeout", 100000);//default 100sec-http://blogs.msdn.com/b/buckh/archive/2005/02/01/365127.aspx)            /*                //try to change - from http://www.codeproject.com/csharp/ClientTicket_MSNP9.asp                                  webRequest.AllowAutoRedirect = false;                       webRequest.Pipelined = false;                        webRequest.KeepAlive = false;                        webRequest.ProtocolVersion = new Version(1,0);//protocol 1.0 works better that 1.1 ??            */            //MNF 26/5/2005 Some web servers expect UserAgent to be specified            //so let's say it's IE6            webRequest.UserAgent = "Mozilla/4.0 (compatible; MSIE 6.0; Windows NT 5.0; .NET CLR 1.1.4322)";            DebugOutputHelper.PrintHttpWebRequest(webRequest, TraceOutputHelper.LineWithTrace(""));            return webRequest;        }Related link:http://stackoverflow.com/questions/387247/i-need-help-setting-net-httpwebrequest-timeoutv

    Read the article

  • WLS Console Timeout

    - by john.graves(at)oracle.com
    The WebLogic console timeout is a great feature for security, yet a horrible feature during development.  Logging in over and over again gets to be annoying.  This is very easy to change, but I would never do this on a production system!   Find the WebLogic consoleapp weblogic.xml file.  This is typically in your WL_HOME/server/lib/consoleapp/webapp/WEB-INF/ directory. Edit the weblogic.xml file: Update the section shown and increase the timeout-secs.  I just throw an extra zero at the end giving me ten full hours of fun!!!: <session-descriptor> <timeout-secs>36000</timeout-secs> <invalidation-interval-secs>60</invalidation-interval-secs> <cookie-name>ADMINCONSOLESESSION</cookie-name> <cookie-max-age-secs>-1</cookie-max-age-secs> <cookie-http-only>false</cookie-http-only> <url-rewriting-enabled>false</url-rewriting-enabled> </session-descriptor> .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }

    Read the article

  • DD-WRT No Internet connection over LAN

    - by algorithms
    I flashed the DD-WRT firmware on my TP-Link WR1043ND router and although after cloning the PC's MAC-Address it gets the correct IP from my ISP, the internet connection over LAN just won't work. The strange thing is it does work flawlessly over W-LAN, which tells me the problem should lie somehow in the default LAN settings or the PC. Any idea what the problem might be? UPDATE: It seems the problem is the desktop PC, since the laptop can connect to the interet via ethernet without any problems. ipconfig /all seems totally normal (dhcp, dns, gateway all set to 192.168.1.1) I already tried the following things without success: disabling firewall rebooting router/modem/pc router hard-reset resetting tcp/ip and winsock manual setting of DNS/IP/Gateway Here is the ipconfig /all: Windows-IP-Konfiguration Hostname . . . . . . . . . . . . : Nitro-PC Primäres DNS-Suffix . . . . . . . : Knotentyp . . . . . . . . . . . . : Hybrid IP-Routing aktiviert . . . . . . : Nein WINS-Proxy aktiviert . . . . . . : Nein Ethernet-Adapter LAN-Verbindung 2: Medienstatus. . . . . . . . . . . : Medium getrennt Verbindungsspezifisches DNS-Suffix: Beschreibung. . . . . . . . . . . : TAP-Win32 Adapter V9 Physikalische Adresse . . . . . . : 00-FF-56-CA-66-8D DHCP aktiviert. . . . . . . . . . : Ja Autokonfiguration aktiviert . . . : Ja Ethernet-Adapter LAN-Verbindung: Verbindungsspezifisches DNS-Suffix: Beschreibung. . . . . . . . . . . : Realtek PCIe GBE Family Controller Physikalische Adresse . . . . . . : 48-5B-39-5B-DE-17 DHCP aktiviert. . . . . . . . . . : Ja Autokonfiguration aktiviert . . . : Ja Verbindungslokale IPv6-Adresse . : fe80::6934:b121:9eab:c6ce%10(Bevorzugt) IPv4-Adresse . . . . . . . . . . : 192.168.1.18(Bevorzugt) Subnetzmaske . . . . . . . . . . : 255.255.255.0 Lease erhalten. . . . . . . . . . : Donnerstag, 30. August 2012 10:52:30 Lease läuft ab. . . . . . . . . . : Freitag, 31. August 2012 10:52:30 Standardgateway . . . . . . . . . : 192.168.1.1 DHCP-Server . . . . . . . . . . . : 192.168.1.1 DHCPv6-IAID . . . . . . . . . . . : 239622969 DHCPv6-Client-DUID. . . . . . . . : 00-01-00-01-17-43-0D-B2-48-5B-39-5B-DE-17 DNS-Server . . . . . . . . . . . : 192.168.1.1 NetBIOS über TCP/IP . . . . . . . : Aktiviert Tunneladapter isatap.{56CA668D-9112-4399-9D9A-F1D42F0E52DE}: Medienstatus. . . . . . . . . . . : Medium getrennt Verbindungsspezifisches DNS-Suffix: Beschreibung. . . . . . . . . . . : Microsoft-ISATAP-Adapter Physikalische Adresse . . . . . . : 00-00-00-00-00-00-00-E0 DHCP aktiviert. . . . . . . . . . : Nein Autokonfiguration aktiviert . . . : Ja Tunneladapter Teredo Tunneling Pseudo-Interface: Verbindungsspezifisches DNS-Suffix: Beschreibung. . . . . . . . . . . : Teredo Tunneling Pseudo-Interface Physikalische Adresse . . . . . . : 00-00-00-00-00-00-00-E0 DHCP aktiviert. . . . . . . . . . : Nein Autokonfiguration aktiviert . . . : Ja IPv6-Adresse. . . . . . . . . . . : 2001:0:5ef5:79fd:1432:3dcd:3f57:feed(Bevorzugt) Verbindungslokale IPv6-Adresse . : fe80::1432:3dcd:3f57:feed%12(Bevorzugt) Standardgateway . . . . . . . . . : :: NetBIOS über TCP/IP . . . . . . . : Deaktiviert Tunneladapter isatap.{AD21069D-D2AF-423E-BF59-0B1CD0D235E8}: Medienstatus. . . . . . . . . . . : Medium getrennt Verbindungsspezifisches DNS-Suffix: Beschreibung. . . . . . . . . . . : Microsoft-ISATAP-Adapter #2 Physikalische Adresse . . . . . . : 00-00-00-00-00-00-00-E0 DHCP aktiviert. . . . . . . . . . : Nein Autokonfiguration aktiviert . . . : Ja Tunneladapter 6TO4 Adapter: Medienstatus. . . . . . . . . . . : Medium getrennt Verbindungsspezifisches DNS-Suffix: Beschreibung. . . . . . . . . . . : Microsoft-6zu4-Adapter Physikalische Adresse . . . . . . : 00-00-00-00-00-00-00-E0 DHCP aktiviert. . . . . . . . . . : Nein Autokonfiguration aktiviert . . . : Ja route PRINT IPv4-Routentabelle =========================================================================== Aktive Routen: Netzwerkziel Netzwerkmaske Gateway Schnittstelle Metrik 0.0.0.0 0.0.0.0 192.168.1.1 192.168.1.18 10 127.0.0.0 255.0.0.0 Auf Verbindung 127.0.0.1 306 127.0.0.1 255.255.255.255 Auf Verbindung 127.0.0.1 306 127.255.255.255 255.255.255.255 Auf Verbindung 127.0.0.1 306 192.168.1.0 255.255.255.0 Auf Verbindung 192.168.1.18 266 192.168.1.18 255.255.255.255 Auf Verbindung 192.168.1.18 266 192.168.1.255 255.255.255.255 Auf Verbindung 192.168.1.18 266 224.0.0.0 240.0.0.0 Auf Verbindung 127.0.0.1 306 224.0.0.0 240.0.0.0 Auf Verbindung 192.168.1.18 266 255.255.255.255 255.255.255.255 Auf Verbindung 127.0.0.1 306 255.255.255.255 255.255.255.255 Auf Verbindung 192.168.1.18 266 =========================================================================== Stndige Routen: Keine

    Read the article

  • Relation between HTTP Keep Alive duration and TCP timeout duration

    - by Suresh Kumar
    I am trying to understand the relation between TCP/IP and HTTP timeout values. Are these two timeout values different or same? Most Web servers allow users to set the HTTP Keep Alive timeout value through some configuration. How is this value used by the Web servers? is this value just set on the underlying TCP/IP socket i.e is the HTTP Keep Alive timeout and TCP/IP Keep Alive Timeout same? or are they treated differently? My understanding is (maybe incorrect): The Web server uses the default timeout on the underlying TCP socket (i.e. indefinite) regardless of the configured HTTP Keep Alive timeout and creates a Worker thread that counts down the specified HTTP timeout interval. When the Worker thread hits zero, it closes the connection. EDIT: My question is about the relation or difference between the two timeout durations i.e. what will happen when HTTP keep-alive timeout duration and the timeout on the Socket (SO_TIMEOUT) which the Web server uses is different? should I even worry about these two being same or not?

    Read the article

  • java.net.SocketException: Connection reset

    - by Darryl
    I am getting the following error trying to read from a socket. I'm doing a readInt() on that InputStream, and I am getting this error. Perusing the documentation this suggests that the client part of the connection closed the connection. In this scenario, I am the server. I have access to the client log files and it is not closing the connection, and in fact its log files suggest I am closing the connection. So does anybody have an idea why this is happening? What else to check for? Does this arise when there are local resources that are perhaps reaching thresholds? Many thanks, Darryl

    Read the article

  • TransactionScope and Connection Pooling

    - by Graham
    Hi, I'm trying to get a handle on whether we have a problem in our application with database connections using incorrect IsolationLevels. Our application is a .Net 3.5 database app using SQL Server 2005. I've discovered that the IsolationLevel of connections are not reset when they are returned to the connection pool (see here) and was also really surprised to read in this blog post that each new TransactionScope created gets its own connection pool assigned to it. Our database updates (via our business objects) take place within a TransactionScope (a new one is created for each business object graph update). But our fetches do not use an explicit transaction. So what I'm wondering is could we ever get into the situation where our fetch operations (which should be using the default IsolationLevel - Read Committed) would reuse a connection from the pool which has been used for an update, and inherit the update IsolationLevel (RepeatableRead)? Or would our updates be guaranteed to use a different connection pool seeing as they are wrapped in a TransactionScope? Thanks in advance, Graham

    Read the article

  • Setting the database connection when using a TransactionScope

    - by eych
    Does the database connection have to be set inside a TransactionScope? Or can I set it in the ctor and then have instance methods create up a TransactionScope? EDIT: e.g. Public Sub New() Dim conn = new SqlConnection(...connection string) Public Sub SomeClassMethod() using ts as new TransactionScope //conn has already been initialized //so, here you can set commands, ExecuteDataSet, etc. vs Public Sub New() //nothing here Public Sub SomeClassMethod() using ts as new TransactionScope conn = new SqlConnection(...connection string) set commands, ExecuteDataSet, etc. the question is do you need to create the connection to the database after you've created a TransactionScope or can it be done before?

    Read the article

  • Open/Close database connection in django

    - by mp0int
    I am using Django and Postgresql as my DBMS. I wish to set a setting that enables to enable/disable database connection. When the connection is set to closed (in settings.py) the site will display a message such as "meintanence mode" or something like that. Django will not show any db connection error message (or mail them to admins). It is appreciated if django do not try to connect to the database at all.

    Read the article

  • Dynamic Connection Strings for Strongly Typed DataSet in a Class Library using App.Config

    - by Luc
    This is my first question on StackOverflow.com and I'm not sure if this is the correct way to do this. I found a similar question titled: Modifying the Data Source for the Strongly Typed Dataset Connection String. However, the answer provided is not working for me. I'm not able to comment on it because I don't have enough "reputation points" (again, I just signed up), and I didn't want to provide an "answer", because I don't know the correct answer. My problem is that I need to be able to modify the connection string inside the generated myproject.dll.config file, but doing so has no effect for me at all. My library still uses the default connection string that was setup at design time. I've tried everything I know to try, but still no luck. I've tried working around the issue using multiple different approaches, but still the problem persists. I can't find any help on the internet with my specific problem either. It would be great if somebody could shed some light as to why my modified config file isn't being read. Useful information: I'm using a Strongly Typed DataSet I don't know the actual connection string at design time. The app.config doesn't allow me to specify a 'User' scoped connection string. I'm tied to a class library (no Windows Forms) Thank you for any help! Luc

    Read the article

  • Auto Encryption of web.config connection string

    - by Klaas Jan
    I want to encrypt the connection string in web.config, the problem is each time a developer changes the connection string in web.config and publishes, it needs to be encrypted every time in the web server. Is there any way that the connection string can encrypted automatically every time someone publishes it? Note :- All of us work on our local machines other than the server. So encryption using local machine key is not an option.

    Read the article

  • Cocoa NSOutputStream send to a connection

    - by Chuck
    Hi, I am new to Cocoa, but managed to get a connection (to a FTP) up and running, and I've set up an eventhandler for the NSInputStream iStream to alert every response (which also works). What I manage to get is simply the hello message and a connection timeout 60 sec, closing control connection. After searching stackoverflow and finding a lot of NSOutputStream write problems (e.g. http://stackoverflow.com/questions/703729/how-to-use-nsoutputstreams-write-message) and a lot of confusion in my google hits, I figured I'd try to ask my own question: I've tried reading the developer.apple.com doc on OutputStream, but it seems almost impossible for me to send some data (in this case just a string) to the "connection" via the NSOutputStream oStream. - (IBAction) send_something: sender { const char *send_command_char = [@"USER foo" UTF8String]; send_command_buffer = [NSMutableData dataWithBytes:send_command_char length:strlen(send_command_char) + 1]; uint8_t *readBytes = (uint8_t *)[send_command_buffer mutableBytes]; NSInteger byteIndex = 0; readBytes += byteIndex; int data_len = [send_command_buffer length]; unsigned int len = ((data_len - byteIndex >= 1024) ? 1024 : (data_len-byteIndex)); uint8_t buf[len]; (void)memcpy(buf, readBytes, len); len = [oStream write:(const uint8_t *)buf maxLength:len]; byteIndex += len; } the above seems not to result in any useable events. typing it under NSStreamEventHasSpaceAvailable sometimes give a response if I spam the ftp by keep creating new connection instances and keep sending some command whenever oStream has free space. In other words, nothing "right" and so I'm still unclear how to properly send a command to the connection. Should I open - write - close every time i want to write to oStream (and thus to the ftp) and can I then expect a reply (hasBytesAvailable event on iStream)? For some reason I find it very difficult to find any clear tutorials on this matter. Seems like there are more than a few in the same position as me: unclear how to use oStream write? Any little bit that can help clear this up is greatly appreciated! If needed I can write the rest of the code. Chuck

    Read the article

  • How do I create a Solution Wide Connection String

    - by Renier
    Hi. Does anyone know if it is possible to create a single connection string that will be accessible to all the projects in a solution (we have about 6). I can create a text file with this information, but we need design time support as well, and it is not practical to have a connection string in every App.Config and Web.config file in the solution. We basically want a Single connection string that is easy to change should the location of the db change, that will also be used by the IDE for design time support Regards, Renier

    Read the article

  • ODBC Connection Pooling

    - by beansy
    I have inherited a suite of .Net c# applications from a developer which talk to an Informix database on a unix server. Instead of using the usual practices for managing the database connections (disposable pattern / "open late / close early"), the code seems to open one ODBC connection when each app loads and doesn't close it. Connection pooling is turned via the ODBC administrator. Is there any way of seeing how many ODBC connections are open? What is the effect of turning off connection pooling? Am I right in thinking the .NET framework will use connection pooling anyway?

    Read the article

  • Connection Multiplexing

    - by whoi
    Hi; Supposing we have opened a connection of type either TCP or UDP to another remote machine. Having this connection, can we allow multiple connections virtually over this connection like VPN(but not VPN)? I mean multiple applications run on remote machine and you try to access to these applications, is there any multiplexing mechanism or concept supporting such feature?

    Read the article

< Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >