Search Results

Search found 3906 results on 157 pages for 'deliberative assembly'.

Page 16/157 | < Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >

  • How do I debug into an ILMerged assembly?

    - by Rory Becker
    Summary I want to alter the build process of a 2-assembly solution, such that a call to ILMerge is invoked, and the build results in a single assembly. Further I would like to be able to debug into the resultant assembly. Preparation - A simple example New Solution - ClassLibrary1 Create a static function 'GetMessage' in Class1 which returns the string "Hello world" Create new console app which references the ClassLibrary. Output GetMessage from main() via the console. You now have a 2 assembly app which outputs "Hello World" to the console. So what next..? I would like to alter the Console app build process, to include a post build step which uses ILMerge, to merge the ClassLibrary assembly into the Console assembly After this step I should be able to: Run the Console app directly with no ClassLibrary1.dll present Run the Console app via F5 (or F11) in VS and be able to debug into each of the 2 projects. Limited Success I read this blogpost and managed to achieve the merge I was after with a post-build command of... "$(ProjectDir)ILMerge.bat" "$(TargetDir)" $(ProjectName) ...and an ILMerge.bat file which read... CD %1 Copy %2.exe temp.exe ILMerge.exe /out:%2.exe temp.exe ClassLibrary1.dll Del temp.exe Del ClassLibrary1.* This works fairly well, and does in fact produce an exe which runs outside the VS environment as required. However it does not appear to produce symbols (.pdb file) which VS is able to use in order to debug into the code. I think this is the last piece of the puzzle. Does anyone know how I can make this work? FWIW I am running VS2010 on an x64 Win7 x64 machine.

    Read the article

  • How is thread synchronization implemented, at the assembly language level?

    - by Martin
    While I'm familiar with concurrent programming concepts such as mutexes and semaphores, I have never understood how they are implemented at the assembly language level. I imagine there being a set of memory "flags" saying: lock A is held by thread 1 lock B is held by thread 3 lock C is not held by any thread etc But how is access to these flags synchronized between threads? Something like this naive example would only create a race condition: mov edx, [myThreadId] wait: cmp [lock], 0 jne wait mov [lock], edx ; I wanted an exclusive lock but the above ; three instructions are not an atomic operation :(

    Read the article

  • Shall i learn Assembly Language or C, to Understand how "real programming" works?

    - by Daniel Upton
    Hello, World.. I'm a web developer mostly working in Ruby and C#.. I wanna learn a low level language so i dont look like an ass infront of my (computer science expert) boss. Ive heard a lot of purist buzz about how assembly language is the only way to learn how computers actually work, but on the other hand C would probably be more useful as a language rather than just for theory. So my question is.. Would Learning C teach me enough computer science theory / low level programming to not look like a common dandy (complete tool)? Thanks! Daniel

    Read the article

  • how to get the size of a C global array into an assembly program written for the avr architecture co

    - by johannes
    I have a .c file with the following uint8_t buffer[32] I have a .S file where I want to do the following cpi r29, buffer+sizeof(buffer) The second argument for cpi muste be an imidiate value not a location. But unfortunetly sizeof() is a c operator. Both files, are getting compiled to seperate object files and linked afterwards. If I do avr-objdump -x file.c. Amongst other things, I get the size of the buffer. So it is already available in the object file. How do I access the size of the buffer in my assembly file at compile time?

    Read the article

  • How to sum up values of an array in assembly?

    - by Pablo Fallas
    I have been trying to create a program which can sum up all the values of an "array" in assembly, I have done the following: ORG 1000H TABLE DB DUP(2,4,6,8,10,12,14,16,18,20) FIN DB ? TOTAL DB ? MAX DB 13 ORG 2000H MOV AL, 0 MOV CL, OFFSET FIN-OFFSET TABLE MOV BX, OFFSET TABLE LOOP: ADD AL, [BX] INC BX DEC CL JNZ LOOP HLT END BTW I am using msx88 to compile this code. But I get an error saying that the code 0 has not been recognized. Any advise?

    Read the article

  • Can I use AppDomain.AssemblyResolve Event to redirect a failed Assembly Load?

    - by esac
    By default, my application references a mixed mode DLL, so this DLL is both 32 and 64 bit. On a 32 bit system, my app is MSIL and loads the 32 bit DLL. On a 64 bit system, my app loads the 64 bit. However on a 64 bit system, in an older version of the assembly that I am referencing, they only created a 32 bit version. So I fail to load this. I was looking at doing it dynamically, and ideally I would want my MSIL app in 64 bit mode to load the 32 bit DLL. Is this possible? Also it would be nice to resolve it to a different version than what I have referenced as well. Any help appreciated.

    Read the article

  • why this assembly program is loaded from the address 0B3D:0000?

    - by viperchaos
    I have seen a assembly program written from a book about assemble: assume cs:code code segment dw 0123h,0456h,0789h,0abch,0defh,0fedh,0cbah,0987h mov bx,0 mov ax,0 mov cx,8 s: add ax,cs:[bx] add bx,2 loop s mov ax,4c00h int 21h code ends end This program's function is to add eight numbers. The author compiled this program in the DOS and use the DEBUG to see how this program be loaded. The author use the R command and got that DS = 0B2DH ES = 0B2D SS = 0B3D CS = 0B3D IP = 0000 And then the author said that this program is loaded from the address 0B3D:0000. I'm a confused that why this program is loaded from the address 0B3D:0000? Is this because the existence of the Program Segment Prefix(PSP)? If the answer is the existence of the PSP, what is in the PSP?

    Read the article

  • Assembly 6800 Looping? Testing specific bits in a word.

    - by Jeremy
    Hi all, Trying to help a friend out with a friend out with some assembly code, but I've run into a small problem. I'm trying to work out how I would loop through a 8 bit binary word and check the value of specific bits. I need to check bits 1, 3, 5 & 7 to see if they are 1. i.e. int count = 1; int bitAdd = 0; foreach (var bit in word) { if (count = 1 || count = 3 || count = 5 || count = 7) { bitAdd += 1; } count += 1; } Help is much appreciated.

    Read the article

  • Assembly: Why does jumping to a label that returns via ret cause a segmentation fault?

    - by Terribad
    Linux Assembly Tutorial states: there is one very important thing to remember: If you are planning to return from a procedure (with the RET instruction), don't jump to it! As in "never!" Doing that will cause a segmentation fault on Linux (which is OK – all your program does is terminate), but in DOS it may blow up in your face with various degrees of terribleness. But I cannot understand why does it causes a segmentation fault. it sounds just like returning from a function. I have a situation where I need to implement the logic "If X happens, call procedure A. Otherwise, call procedure B." Is there any other way than jumping around like a kangaroo weaving spaghetti code?

    Read the article

  • IIS can't load Oracle.Web assembly (for ASP.NET membership provider)

    - by Konamiman
    I am trying to configure an IIS web site to use an Oracle database for ASP.NET membership, but I can't get it to work. IIS doesn't seem to be able to load the assembly containing the Oracle membership provider. That's what I have so far: An Oracle 10g database online and with all the tables for ASP.NET membership created. Windows 2008 R2 Standard with the web server role installed, including support for ASP.NET. Oracle 11g Release 2 ODAC 11.2.0.1.2 installed. The installed components are: Oracle data provider for .NET, Oracle providers for ASP.NET, Oracle instant client. The default web site on IIS (I am using that for testing) has the following web.config file: <?xml version="1.0" encoding="UTF-8"?> <configuration> <system.web> <membership defaultProvider="OracleMembershipProvider"> <providers> <remove name="SqlMembershipProvider" /> <add name="OracleMembershipProvider" type="Oracle.Web.Security.OracleMembershipProvider, Oracle.Web, Version=2.112.1.2, Culture=neutral, PublicKeyToken=89b483f429c47342" connectionStringName="OracleServer" /> </providers> </membership> </system.web> </configuration> (Additional attributes on the "add" element omitted for brevity. Also, the connection string is defined for the whole server.) The Oracle.Web.dll file is on the GAC. That's the relevant part of the C:\Windows\Assembly folder: The web site application pool is configured for .NET 2.0, and has 32-bit applications enabled. I have allowed untrusted providers in the IIS' administration.config file (just for the sake of testing, I'll explicitly add the assembly to the trusted providers list later). With all of this setup in place, when I click on the ".NET Users" icon on the IIS manager, I get a warning about the provider having too much privileges, and when I accept I get the following message: There was an error while performing this operation. Details: Could not load file or assembly 'Oracle.Web, Version=2.112.1.2, Culture=neutral, PublicKeyToken=89b483f429c47342' or one of its dependencies. The system cannot find the file specified. So, what am I missing? How can I get the Oracle membership provider to work? Thank you! UPDATE: It seems that the problem is not with IIS itself, but with the IIS administrator only. When using the web site configuration tool provided by Visual Studio, everything works fine.

    Read the article

  • Extracting a SQLCLR assembly

    - by Ed Leighton-Dick
    One of our in-house applications has a SQLCLR assembly which is currently experiencing problems. The developer is having problems recreating the issue using the version that is stored in our source control system, so he suspects that some code may have been released that was not uploaded to source control. Is there a way to extract a SQLCLR assembly into a .dll file so that he can reverse engineer it for analysis?

    Read the article

  • SQL CLR Assembly Error 80131051 when late binding to a registered C# COM .dll

    - by Shanubus
    I must have hit an unusual one, because I can't find any reference to this specific failing anywhere... Scenario: I have a legacy SQL function used to transform(encrypt) data. This function is called from within many stored procedures used by multiple applications. I say this, because the obvious answer of 'just call it from your code' is not really an option (or at least one I'd prefer not explore). The legacy function used sp_OA with an ActiveX dll on SQL2000 to perform its work. The new function is targeted at SQL2008 x64. I am ditching the sp_OA call in favor of CLR assembly; and am getting rid of the ActiveX dll and using a COM+ .dll (3rd party) to perform the same work. This 3rd party COM+ is required to be used based on spec given to me, so can't get rid of this piece either. Problem: After multiple attempts at getting this to work I have eliminated the following approaches 1) Create a Sql Assembly to call the local COM+ directly -- Can't do this as it requires a reference to System.EnterpriseServices. Including this requires that a whole slew of unsupported assemblies be registered which I don't want. The COM+ requires it's methods to be accessed via an Interface, so my attempts at late binding to it directly have not been successful (late binding would allow me to drop the unsupported references). 2) Create a Sql Assembly which references a C# class library that then calls the COM+. -- Same issue as #1; since the referenced dll uses System.EnterpriseServices and will be added as a dependency when referenced in the Sql Assembly, again trying to load all the unsupported libraries 3) Create a Sql Assembly which late binds to an ActiveX COM dll that calls the COM+. -- Worked in my dev environment, but can't go to x64 in production with ActiveX dll's written in VB6 (not to mention I hate backtracking anyway)... again failure... I am now onto an approach that is almost working, with of course one last hangup. I now have -a Sql Assembly that late binds to a C# COM dll, eliminating the need for including System.EnterpriseServices and eliminating the need to reference the C# COM in the SqlAssembly itself. The C# COM does reference System.EnterpriseServices to call the COM+, but since I am late binding to it from the SqlAssembly, I bypass the need for Sql to actually load them as referenced assemblies. Works in debugger.. Works on my dev box when the SqlAssembly dll is referenced in a test console app and called directly Installs to Sql2008 just fine Executing the actual UDF works, but returns no data due to a failure reporting from the late bound dll! So the SqlAssembly is instanciated just fine. It actually fails on it's late binding to the C# COM, which is working from a test console app on the same machine. It appears to be a difference in behavior based on whether called from within the SQL UDF or not. Since it is working on the same box from my console app, I am assuming it's on the SQL side. My steps to install were. --Install the COM+ dll and ensure it can be called successfully (as from with in the console app) --Register the C# COM dll (which calls the COM+) and get it to the GAC (again proofed to be working from console app) --Create my Assymetric Key CREATE ASYMMETRIC KEY SqlCryptoKey FROM EXECUTABLE FILE = 'D:\SqlEx.dll' CREATE LOGIN SqlExLogin FROM ASYMMETRIC KEY SqlExKey GRANT UNSAFE ASSEMBLY TO SqlExLogin GO --Add the assembly CREATE ASSEMBLY SqlEx FROM 'D:\SqlEx.dll' WITH PERMISSION_SET = UNSAFE; GO --Create the function CREATE FUNCTION dbo.f_SqlEx( @clearText [nvarchar](512) ) RETURNS nvarchar(512) WITH EXECUTE AS CALLER AS EXTERNAL NAME SqlEx.[SqlEx.SqlEx].Ex GO With all that done, I can now call my function SELECT dbo.f_SqlEx('test') But get this error in the event log... Retrieving the COM class factory for component with CLSID {F69D6320-5884-323F-936A-7657946604BE} failed due to the following error: 80131051. I can't really provide direct code examples, due to internal security implications; but all the code itself seems to work, I am suspecting perms or something of the like... I just find it odd that I can't find any reference to error 80131051. If someone out there believe some 'indirect' code samples will help, I will be happy to provide. Any assistance is appreciated.

    Read the article

  • 1k of Program Space, 64 bytes of RAM. Is assembly an absolute must?

    - by Earlz
    (If your lazy see bottom for TL;DR) Hello, I am planning to build a new (prototype) project dealing with physical computing. Basically, I have wires. These wires all need to have their voltage read at the same time. More than a few hundred microseconds difference between the readings of each wire will completely screw it up. The Arduino takes about 114 microseconds. So the most I could read is 2 or 3 wires before the latency would skew the accuracy of the readings. So my plan is to have an Arduino as the "master" of an array of ATTinys. The arduino is pretty cramped for space, but it's a massive playground compared to the tinys. An ATTiny13A has 1k of flash ROM(program space), 64 bytes of RAM, and 64 bytes of (not-durable and slow) EEPROM. (I'm choosing this for price as well as size) The ATTinys in my system will not do much. Basically, all they will do is wait for a signal from the Master, and then read the voltage of 1 or 2 wires and store it in RAM(or possibly EEPROM if it's that cramped). And then send it to the Master using only 1 wire for data.(no room for more than that!). So far then, all I should have to do is implement trivial voltage reading code (using built in ADC). But this communication bit I'm worried about. Do you think a communication protocol(using just 1 wire!) could even be implemented in such constraints? TL;DR: In less than 1k of program space and 64 bytes of RAM(and 64 bytes of EEPROM) do you think it is possible to implement a 1 wire communication protocol? Would I need to drop to assembly to make it fit? I know that currently my Arduino programs linking to the Wiring library are over 8k, so I'm a bit concerned.

    Read the article

  • x86 Assembly: Before Making a System Call on Linux Should You Save All Registers?

    - by mudge
    I have the below code that opens up a file, reads it into a buffer and then closes the file. The close file system call requires that the file descriptor number be in the ebx register. The ebx register gets the file descriptor number before the read system call is made. My question is should I save the ebx register on the stack or somewhere before I make the read system call, (could int 80h trash the ebx register?). And then restore the ebx register for the close system call? Or is the code I have below fine and safe? I have run the below code and it works, I'm just not sure if it is generally considered good assembly practice or not because I don't save the ebx register before the int 80h read call. ;; open up the input file mov eax,5 ; open file system call number mov ebx,[esp+8] ; null terminated string file name, first command line parameter mov ecx,0o ; access type: O_RDONLY int 80h ; file handle or negative error number put in eax test eax,eax js Error ; test sign flag (SF) for negative number which signals error ;; read in the full input file mov ebx,eax ; assign input file descripter mov eax,3 ; read system call number mov ecx,InputBuff ; buffer to read into mov edx,INPUT_BUFF_LEN ; total bytes to read int 80h test eax,eax js Error ; if eax is negative then error jz Error ; if no bytes were read then error add eax,InputBuff ; add size of input to the begining of InputBuff location mov [InputEnd],eax ; assign address of end of input ;; close the input file ;; file descripter is already in ebx mov eax,6 ; close file system call number int 80h

    Read the article

  • Where to go after having a good grasp of a language?

    - by Alex M.
    I have been programming as a hobby for the past few years now (most of high school and 1 year in cs in college) and although I've came to the conclusion that a career in CS isn't for me I switched over to math (which pairs what I love about programming with my interest in physical sciences) but I miss writing code. Recently I've had an interest in low-level programming. Understanding how compilers work, learning some basics of assembly language and trying to get out of my comfort zone. The problem is that since I've been out of the CS programs, I'm not faced with much opportunities to write code. I do intend to take a few CS classes in college (a lot of CS stuff is opened to math majors) but that won't come for until next year. So I ask: What are the steps to take in order to keep improving as a programmer once you're passed the basic steps? How do you find projects to keep you going? Beside my newly discovered interest in assembly language, I've been writing code in C and have been interested in FOSS. Thanks!

    Read the article

  • ASP.NET MVC tries to load older version of Owin assembly

    - by d_mcg
    As a bit of context, I'm developing an ASP.NET MVC 5 application that uses OAuth-based authentication via Microsoft's OWIN implementation, for Facebook and Google only at this stage. Currently (as of v3.0.0, git-commit 4932c2f), the FacebookAuthenticationOptions and GoogleOAuth2AuthenticationOptions don't provide any property to force Facebook nor Google respectively to reauthenticate users (via appending the appropriate query string parameters) when signing in. Initially, I set out to override the following classes: FacebookAuthenticationOptions GoogleOAuth2AuthenticationOptions FacebookAuthenticationHandler (specifically AuthenticateCoreAsync()) GoogleOAuth2AuthenticationHandler (specifically AuthenticateCoreAsync()) yet discovered that the ~AuthenticationHandler classes are marked as internal. So I pulled a copy of the source for the Katana project (http://katanaproject.codeplex.com/) and modified the source accordingly. After compiling, I found that there are several dependencies that needed updating in order to use these updated assemblies (Microsoft.Owin.Security.Facebook and Microsoft.Owin.Security.Google) in the MVC project: Microsoft.Owin Microsoft.Owin.Security Microsoft.Owin.Security.Cookies Microsoft.Owin.Security.OAuth Microsoft.Owin.Host.SystemWeb This was done by replacing the existing project references to the 3.0.0 versions and updating those in web.config. Good news: the project compiles successfully. In debugging, I received an exception on startup: An exception of type 'System.IO.FileLoadException' occurred in [MVC web assembly].dll but was not handled in user code Additional information: Could not load file or assembly 'Microsoft.Owin.Security, Version=3.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The located assembly's manifest definition does not match the assembly reference. (Exception from HRESULT: 0x80131040) The underlying exception indicated that Microsoft.AspNet.Identity.Owin was trying to load v2.1.0 of Microsoft.Owin.Security when calling app.UseExternalSignInCookie() from Startup.ConfigureAuth(IAppBuilder app) in Startup.Auth.cs. Unfortunately that assembly (and its other dependency, Microsoft.AspNet.Identity.Owin) aren't part of the Project Katana solution, and I can't find any accessible repository for these assemblies online. Are the Microsoft.AspNet.Identity assemblies open source, like the Katana project? Is there a way to fool those assemblies to use the referenced v3.0.0 assemblies instead of v2.1.0? The /bin folder contains the 3.0.0 versions of the Owin assemblies. I've upgraded the NuGet packages for Microsoft.AspNet.Identity.Owin, and this is still an issue. Any ideas on how to resolve this issue?

    Read the article

  • NserviceBus throws exception when referencing a Nettiers assembly

    - by IGoor
    We use nettiers as a our data layer, and we recently have started looking at using NServiceBus, but we have hit a wall. We have a windows service which hosts NSB and references our Nettiers assembly. the service is throwing an exception when the following line is encountered. var Bus = Configure.With().SpringBuilder() .XmlSerializer() .MsmqTransport() .IsTransactional(false) .PurgeOnStartup(false) .UnicastBus() .ImpersonateSender(false) .CreateBus() .Start(); the exceptions that is throw is: Unable to load one or more of the requested types. Retrieve the LoaderExceptions property for more information. the loader exception message is: Could not load file or assembly 'Microsoft.Practices.Unity, Version=1.2.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified.":"Microsoft.Practices.Unity, Version=1.2.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35 stacktrace is: at System.Reflection.Module._GetTypesInternal(StackCrawlMark& stackMark) at System.Reflection.Assembly.GetTypes() at NServiceBus.Configure.<>c__DisplayClass1.<With>b__0(Assembly a) in d:\BuildAgent-03\work\672d81652eaca4e1\src\config\NServiceBus.Config\Configure.cs:line 122 at System.Array.ForEach[T](T[] array, Action`1 action) at NServiceBus.Configure.With(Assembly[] assemblies) in d:\BuildAgent-03\work\672d81652eaca4e1\src\config\NServiceBus.Config\Configure.cs:line 122 at NServiceBus.Configure.With(IEnumerable`1 assemblies) in d:\BuildAgent-03\work\672d81652eaca4e1\src\config\NServiceBus.Config\Configure.cs:line 111 at NServiceBus.Configure.With(String probeDirectory) in d:\BuildAgent-03\work\672d81652eaca4e1\src\config\NServiceBus.Config\Configure.cs:line 101 at NServiceBus.Configure.With() in d:\BuildAgent-03\work\672d81652eaca4e1\src\config\NServiceBus.Config\Configure.cs:line 78 at MessageSender.Program.Main(String[] args) in C:\Development\NSBTest4\MessageSender\Program.cs:line 18 without the nettiers reference NSB works fine. Any idea what the problem is and how to solve it? thanks.

    Read the article

  • Sharing an assembly between ASP.NET and Silverlight

    - by vtortola
    Hi, I've created an assembly to share it between my main app and the silverlight app. At the beginning it looked like it was going to work but now I get this exception: "System.IO.FileNotFoundException was caught, Message="Could not load file or assembly 'System.Xml.Linq". I'm using .NET 3.5 Sp1 and Silverlight 3. That shared assembly uses System.Xml.Linq, and it cannot find it... I think because it is trying to find that version in the .NET framework instead looking in the silverlight one. How can I fix this? Cheers. PS: this is the full exception output: System.IO.FileNotFoundException was caught Message="Could not load file or assembly 'System.Xml.Linq, Version=2.0.5.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified." Source="MyApp.Metadata" FileName="System.Xml.Linq, Version=2.0.5.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35" FusionLog="=== Pre-bind state information ===\r\nLOG: User = IIS APPPOOL\DefaultAppPool\r\nLOG: DisplayName = System.Xml.Linq, Version=2.0.5.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35\n (Fully-specified)\r\nLOG: Appbase = file:///C:/Users/vtortola.MyApp/Documents/MyApp/MyAppSAS/WebApplication1/WebApplication1/\r\nLOG: Initial PrivatePath = C:\Users\vtortola.MyApp\Documents\MyApp\MyAppSAS\WebApplication1\WebApplication1\bin\r\nCalling assembly : MyApp.Metadata, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null.\r\n===\r\nLOG: This bind starts in default load context.\r\nLOG: Using application configuration file: C:\Users\vtortola.MyApp\Documents\MyApp\MyAppSAS\WebApplication1\WebApplication1\web.config\r\nLOG: Using host configuration file: C:\Windows\Microsoft.NET\Framework64\v2.0.50727\Aspnet.config\r\nLOG: Using machine configuration file from C:\Windows\Microsoft.NET\Framework64\v2.0.50727\config\machine.config.\r\nLOG: Post-policy reference: System.Xml.Linq, Version=2.0.5.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35\r\nLOG: The same bind was seen before, and was failed with hr = 0x80070002.\r\n" StackTrace: at MyApp.Metadata.MyAppEntity.Deserialize(String message)

    Read the article

  • Referencing .NET Assembly in VB6 won't work

    - by dretzlaff17
    I wrote a .net assembly using c# to perform functions that will be used by both managed and unmanaged code. I have a VB6 project that now needs to use the assembly via COM. I created my .net assembly, made sure that ComVisible is set to true and that it is registered for COM interop via project properties. public class MyClass [ComVisible(true)] public string GetResponse() { return "Testing Response" } } I build the assembly and copied the file into a folder. TestInterop.dll I then run a batch file to register the assembly tool to register the object for COM. cd C:\Windows\Microsoft.NET\Framework\v4.0.30319\ regasm "c:\Program Files\TestApp\TestInterop.dll" /tlb:TestInterop.tlb I open a new VB6 application and reference TestInterop.dll In VB6 I write the following code and it compiles. Dim obj as TestInterop.MyClass Set obj = new TestInterop.MyClass Dim strTest as string strTest = obj.GetRespose() When I run the program it errors on the obj.GetResponse() line. Run-time error' -2147024894 (80070002'): Automation error The system cannot find the file specified Also, the intellesense does not work on obj. I had to type the GetResponse method. Is this normal? Does anyone have any clue what could be wrong or what steps I missed. Thanks!

    Read the article

  • Could not load file or assembly log4net or one of its dependencies

    - by Elie
    I've been asked to take a look at an error in an ASP/C# application with its Paypal integration. The error, shown in full, is: Could not load file or assembly 'log4net, Version=1.2.0.30714, Culture=neutral, PublicKeyToken=b32731d11ce58905' or one of its dependencies. The located assembly's manifest definition does not match the assembly reference. (Exception from HRESULT: 0x80131040) From what I understand, this means that the actual file located (that is, log4net.dll in my bin directory) does not match the version expected based on some assembly configuration. The problem I'm having is that I cannot locate where this file is being referenced. I have access to all the files in the web root directory of the site, and cannot locate any config files that reference this DLL. Where else might I need to look to determine what's causing the mis-match? As a note, I've made sure that the version of the DLL in the bin directory is up to date, but this does not seem to have resolved anything.

    Read the article

  • Why is Assembly.GetCustomAttributes suddenly throwing TypeLoadException on build machine with Silver

    - by andrej351
    A short while back i had to display the current version of our Silverlight app. After some googling the following code gave me the desired result: var fileVersionAttributes = typeof(MyClass).Assembly. GetCustomAttributes(typeof(AssemblyFileVersionAttribute), false) as AssemblyFileVersionAttribute[]; var version = fileVersionAttributes[0].Version; This worked a treat in our .NET 3.5 Silverlight 3 environment. However, we recently upgraded to .NET 4 and Silverlight 4. We just finished getting our build machine working and found that the unit test for this code was throwing the following exception: Exception Message: System.TypeLoadException: Error 0x80131522. Debugging resource strings are unavailable. See http://go.microsoft.com/fwlink/?linkid=106663&Version=3.0.50106.0&File=mscorrc.dll&Key=0x80131522 at System.ModuleHandle.ResolveType(ModuleHandle module, Int32 typeToken, RuntimeTypeHandle* typeInstArgs, Int32 typeInstCount, RuntimeTypeHandle* methodInstArgs, Int32 methodInstCount) at System.ModuleHandle.ResolveTypeHandle(Int32 typeToken, RuntimeTypeHandle[] typeInstantiationContext, RuntimeTypeHandle[] methodInstantiationContext) at System.Reflection.Module.ResolveType(Int32 metadataToken, Type[] genericTypeArguments, Type[] genericMethodArguments) at System.Reflection.CustomAttribute.FilterCustomAttributeRecord(CustomAttributeRecord caRecord, MetadataImport scope, Assembly& lastAptcaOkAssembly, Module decoratedModule, MetadataToken decoratedToken, RuntimeType attributeFilterType, Boolean mustBeInheritable, Object[] attributes, IList derivedAttributes, RuntimeType& attributeType, RuntimeMethodHandle& ctor, Boolean& ctorHasParameters, Boolean& isVarArg) at System.Reflection.CustomAttribute.GetCustomAttributes(Module decoratedModule, Int32 decoratedMetadataToken, Int32 pcaCount, RuntimeType attributeFilterType, Boolean mustBeInheritable, IList derivedAttributes, Boolean isDecoratedTargetSecurityTransparent) at System.Reflection.CustomAttribute.GetCustomAttributes(Module decoratedModule, Int32 decoratedMetadataToken, Int32 pcaCount, RuntimeType attributeFilterType, Boolean isDecoratedTargetSecurityTransparent) at System.Reflection.CustomAttribute.GetCustomAttributes(Assembly assembly, Type caType) at System.Reflection.Assembly.GetCustomAttributes(Type attributeType, Boolean inherit) at MyCode.VersionTest() I have never seen this exception before and the link in it points nowhere. It is only throwing on the build machine and not on my development box, so i'm going through a process of trial and error to see any differences between the two. Any idea why this might be happening?? Cheers, Andrej.

    Read the article

  • Find out if assembly is signed with Authenticode

    - by crauscher
    I use an assembly of a 3rd party vendor. In an older version this assembly used authenticode. This caused the assembly loading to last quiet long. The developer of the vendor told me that the new version is not signed with authenticode. How can I check if this is true. On my development machine the assembly loading was quiet fast. Only on client machines it took quiet a while. Is it possible to check this using a network sniffer? Regards

    Read the article

  • What happens when I load an assembly?

    - by Baddie
    In my ASP.NET MVC application, I have the following setup: <runtime> <assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1"> <probing privatePath="bin;extras"/> I have referenced assemblies located in the extras folder in the views and they have worked perfectly (using <%@ Import Namespace="myNameSpace" %>). My questions What happens when that line is called? Where is the assembly loaded? Why is it that I can't overwrite the assembly located in the extras folder that contains myNameSpace with a newer version? (I get an error saying that the assembly is "open" in another program) Is there a way to overwrite the assembly with a newer version without having the application restart?

    Read the article

  • Recommended Visual Studio config for referencing an assembly created with ILMerge

    - by Daniel Schaffer
    I have a solution in Visual Studio with 5 projects. They are: Foo.Core: Core functionality Foo.Api: Generated code built on top of core Foo.Web: Web-specific extensions Foo.Web.Mvc: MVC-specific extensions Newtonsoft.Json: 3rd party library I want to use ILMerge to merge Foo.Core, Foo.Api and Newtonsoft.Json into a single assembly, called Foo. That's the easy part. The problem I'm running into is that Foo.Web and Foo.Web.Mvc both need to reference all three of the merged assemblies. If I reference the original assemblies, they will have invalid references after I do the ILMerge. If I reference the ILMerged assembly, I have to reference a debug assembly and then change it before I package everything up, which doesn't seem ideal. I've tried creating a project called Foo, which references the 3 merged assemblies and replaces its own output with the ILmerged assembly, but that doesn't seem to work at all. Is there a reliable way to do this?

    Read the article

< Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >