Search Results

Search found 886 results on 36 pages for 'interop domino'.

Page 16/36 | < Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >

  • Strange behaviour using Drag and Drop in word 2003 automation in headers

    - by Oliver Hanappi
    Hi! I am developing a template based addin for Word 2003 which allows the user to drag and drop elements from a listbox into the word document. Unfortunately I'm getting a really strange behaviour when trying to drop elements in the document's header. Open the template and type something in the header Close the header and insert some content on the page Add a page break. Switch to page layout mode where and set zoom level to "Two Pages" Open the header Slowly Drag and Drop an list item from the list box to the header. See multiple Page Setups dialogs occur which cause Word to crash. Here is my code: // in ThisDocument.cs public MyUserControl _control; public void Init() { _control = new MyUserControl(); ActionsPane.Controls.Add(_control); ActionsPane.Visible = true; } // in MyUserControl.cs public void listBox1_MouseDown(object sender, MouseEventArgs e) { DoDragDrop("something", DragDropEffects.Copy); } Have I done somethinkg wrong with implementing Drag and Drop? Is there a workaround for this strange behaviour? Thanks in advance, Oliver Hanappi

    Read the article

  • How to obtain the native stacktrace from native exceptions caught in managed code

    - by aaa
    I have some managed code that calls to a method inside some native DLL(i have the appropriate symbol files). Sometimes, that native method throws an exception which I catch in my managed code. However, when i print the stacktrace from my caught exception, I see only managed code (the last frame is the call to the native code .. but it don't see the stacktrack within the native code). How can I obtain the native callstack as well? *When i'm debugging the code, i am able to step into the native code, and see the actuall call stack.

    Read the article

  • Why would you need to run regasm and caspol on a .net component more than once?

    - by Craig Johnston
    Why would you need to run regasm and caspol on a .NET component more than once? I have a COM client that uses a .NET component residing on another machine. Consequently I need to run regasm and caspol on this .NET component. What could cause there to be the need to do this again on the same machine to the same component? Is the effect of regasm and caspol only temporary? Or can I assume that someone has reset or cleared something on a machine if I am having to do this again?

    Read the article

  • Parsing a .NET DataSet returned from a .NET Web Service in Java

    - by Chris Dail
    I have to consume a .NET hosted web service from a Java application. Interoperability between the two is usually very good. The problem I'm running into is that the .NET application developer chose to expose data using the .NET DataSet object. There are lots of articles written as to why you should not do this and how it makes interoperability difficult: http://www.hanselman.com/blog/ReturningDataSetsFromWebServicesIsTheSpawnOfSatanAndRepresentsAllThatIsTrulyEvilInTheWorld.aspx http://www.lhotka.net/weblog/ThoughtsOnPassingDataSetObjectsViaWebServices.aspx http://aspnet.4guysfromrolla.com/articles/051805-1.aspx http://www.theserverside.net/tt/articles/showarticle.tss?id=Top5WSMistakes My problem is that despite this not being recommended practice, I am stuck with having to consume a web service returning a DataSet with Java. When you generate a proxy for something like this with anything other than .NET you basically end up with an object that looks like this: @XmlElement(namespace = "http://www.w3.org/2001/XMLSchema", required = true) protected Schema schema; @XmlAnyElement(lax = true) protected Object any; This first field is the actual schema that should describe the DataSet. When I process this using JAX-WS and JAXB in Java, it bring all of XS-Schema in as Java objects to be represented here. Walking the object tree of JAXB is possible but not pretty. The any field represents the raw XML for the DataSet that is in the schema specified by the schema. The structure of the dataset is pretty consistent but the data types do change. I need access to the type information and the schema does vary from call to call. I've though of a few options but none seem like 'good' options. Trying to generate Java objects from the schema using JAXB at runtime seems to be a bad idea. This would be way too slow since it would need to happen everytime. Brute force walk the schema tree using the JAXB objects that JAX-WS brought in. Maybe instead of using JAXB to parse the schema it would be easier to deal with it as XML and use XPath to try and find the type information I need. Are there other options I have not considered? Is there a Java library to parse DataSet objects easily? What have other people done who may have similar situations?

    Read the article

  • Is there any way, short of "copy and paste inheritence" to share a .net class with a Silverlight app

    - by Jekke
    I have a project in two parts: a Silverlight front end and a WCF duplex service. Ideally, I would like to pass a message of a custom type (call it TradeOffer) from the WCF service to be consumed by the Silverlight application. When I try to, I get an error that indicates I can't pass an object of an unknown type across the wire like that and that, maybe, I could do so if I used the InternalsVisibleTo attribute on the server component. I'm not sure if that would work in this environment and know it would be messy in development. I originally put the message definition in a library to be used by both the service and the client, but couldn't add a reference to the library from the Silverlight client (because it's not a Silverlight assembly.) Is there some way I can access the definition of a message class from both the Silverlight client that consumes it and the service that publishes it without using the InternalsVisibleTo attribute or should I write the application another way?

    Read the article

  • Blittable Value Types

    - by Michael Covelli
    Here is a list of blittable types. It contains Int32 and Int64. But I don't see just plain "int" on the list. How does C# treat the plain "int" type? Does it just get replaced with Int32 or Int64 depending on the system? Or is there a subtle difference? Will using "int" ever cause a performance hit for marshalling?

    Read the article

  • Access COM object through a windows process handle.

    - by Sivvy
    I'm currently automating an application at work using COM, and have an issue where anyone using my application has a problem if the original application is already open when my application runs. I know how to locate the process if it's open, but instead of having to worry about closing it, or working around it, etc., I want to try to use the existing application instead of opening a new one. This is how I normally start the application in my automation program: Designer.Application desApp = new Designer.Application(); Now I'm attempting to try and use the handle from an existing application: Designer.Application desApp = (Designer.Application)((System.Diagnostics.Process.GetProcessesByName("Designer.exe")[0]).Handle) (I know this doesn't work, since .Handle returns an IntPtr, but I'm using it as an example.) Is there any way to accomplish this? How do I return a usable object if I know the handle/process?

    Read the article

  • How to declare and implement a COM interface on C# that inherits from another COM interface?

    - by Carlos Loth
    I'm trying to understand what is the correct why to implement COM interfaces from C# code. It is straightforward when the interface doesn't inherit from other base interface. Like this one: [ComImport, Guid("2047E320-F2A9-11CE-AE65-08002B2E1262"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IShellFolderViewCB { long MessageSFVCB(uint uMsg, int wParam, int lParam); } However things start to become weired when I need to implement an interface that inherits from other COM interfaces. For example, if I implement the IPersistFolder2 interface which inherits from IPersistFolder which inherits from IPersist as I usually on C# code: [ComImport, Guid("0000010c-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IPersist { void GetClassID([Out] out Guid classID); } [ComImport, Guid("000214EA-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IPersistFolder : IPersist { void Initialize([In] IntPtr pidl); } [ComImport, Guid("1AC3D9F0-175C-11d1-95BE-00609797EA4F"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IPersistFolder2 : IPersistFolder { void GetCurFolder([Out] out IntPtr ppidl); } The operating system is not able to call the methods on my object implementation. When I'm debugging I can see the constructor of my IPersistFolder2 implementation is called many times, however the interface methods I've implemented aren't called. I'm implementing the IPersistFolder2 as follows: [Guid("A4603CDB-EC86-4E40-80FE-25D5F5FA467D")] public class PersistFolder: IPersistFolder2 { void IPersistFolder2.GetClassID(ref Guid classID) { ... } void IPersistFolder2.Initialize(IntPtr pidl) { ... } void IPersistFolder2.GetCurFolder(out IntPtr ppidl) { ... } } What seems strange is when I declare the COM interface imports as follow, it works: [ComImport, Guid("0000010c-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] internal interface IPersist { void GetClassID([Out] out Guid classID); } [ComImport, Guid("000214EA-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] internal interface IPersistFolder : IPersist { new void GetClassID([Out] out Guid classID); void Initialize([In] IntPtr pidl); } [ComImport, Guid("1AC3D9F0-175C-11d1-95BE-00609797EA4F"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] internal interface IPersistFolder2 : IPersistFolder { new void GetClassID([Out] out Guid classID); new void Initialize([In] IntPtr pidl); void GetCurFolder([Out] out IntPtr ppidl); } I don't know why it works when I declare the COM interfaces that way (hidding the base interface methods using new). Maybe it is related to the way IUnknown works. Does anyone know what is the correct way of implementing COM interfaces in C# that inherits from other COM interfaces and why?

    Read the article

  • Outlook VSTO AddIn Configuration

    - by Deepak N
    I'm working on VSTO addin for outlook 2003.Outlook can read the startup section from Outlook.exe.config. <startup> <supportedRuntime version="v1.0.3705" /> <supportedRuntime version="v1.1.4322" /> <supportedRuntime version="v2.0.50727" /> </startup> But it is not able to read the system.diagnostics section of the config file. Basically i'm trying add trace listeners as i have explained here.Am I missing any thing here.

    Read the article

  • Using TaskDialogIndirect in C#

    - by Dennis Delimarsky
    I've been working for a while with the regular Windows Vista/7 TaskDialog for a while, and I wanted to add some additional functionality (like custom buttons and a footer), so I need to use TaskDialogIndirect. Following the MSDN documentation for TaskDialogIndirect, I got this signature: [DllImport("comctl32.dll",CharSet = CharSet.Unicode,EntryPoint="TaskDialogIndirect")] static extern int TaskDialogIndirect (TASKDIALOGCONFIG pTaskConfig, out int pnButton, out int pnRadioButton, out bool pfVerificationFlagChecked); The TASKDIALOGCONFIG class is shown below: public class TASKDIALOGCONFIG { public UInt16 cbSize; public IntPtr hwndParent; public IntPtr hInstance; public String dwFlags; public String dwCommonButtons; public IntPtr hMainIcon; public String pszMainIcon; public String pszMainInstruction; public String pszContent; public UInt16 cButtons; public TASKDIALOG_BUTTON pButtons; public int nDefaultButton; public UInt16 cRadioButtons; public TASKDIALOG_BUTTON pRadioButtons; public int nDefaultRadioButton; public String pszVerificationText; public String pszExpandedInformation; public String pszExpandedControlText; public String pszCollapsedControlText; public IntPtr hFooterIcon; public IntPtr pszFooterText; public String pszFooter; // pfCallback; // lpCallbackData; public UInt16 cxWidth; } The TASKDIALOG_BUTTON implementation: public class TASKDIALOG_BUTTON { public int nButtonID; public String pszButtonText; } I am not entirely sure if I am on the right track here. Did anyone use TaskDialogIndirect from managed code directly through WinAPI (without VistaBridge or Windows API Code Pack)? I am curious about the possible implementations, as well as the callback declarations (I am not entirely sure how to implement TaskDialogCallbackProc). PS: I am looking for a direct WinAPI implementation, not one through a wrapper.

    Read the article

  • Marshal a list of objects from VB6 to C#

    - by Andrew
    I have a development which requires the passing of objects between a VB6 application and a C# class library. The objects are defined in the C# class library and are used as parameters for methods exposed by other classes in the same library. The objects all contain simple string/numeric properties and so marshaling has been relatively painless. We now have a requirement to pass an object which contains a list of other objects. If I was coding this in VB6 I might have a class containing a collection as a member variable. In C# I might have a class with a List member variable. Is it possible to construct a C# class in such a way that the VB6 application could populate this inner list and marshal it successfully? I don't have a lot of experience here but I would guess Id have to use an array of Object types.

    Read the article

  • Accessing underlying managed object through a COM interface

    - by mfeingold
    I have a third party assembly with a public abstract class implementing a certain COM interface. Something to the effect of [ComVisible(true)] public abstract class SomeClass: ISomeInterface { .... public void Method1() {...} } The actual object is an internal object extending the SomeClass and is instantiated by the third party code Is there a way to access public methods of this class if all I have is the CCW to the ISomeInterface?

    Read the article

  • Visual C# | Capturing data from a window in a closed-source third-party Win32 application

    - by Zach Albia
    I'm planning on creating a C# Windows Forms app as an extension for a third-party Win32 application but I'm stumped as to how to do this right now. The farthest I've gotten is knowing it involves Win32 Hooking and that there's this open source project called EasyHook that's supposed to allow me to do this. I'd like to know how I can get the text from a textbox or some other data from a control in a third-party Win32 application. The text/data in a control is to be captured from the external application's running window the moment the user presses a button. I guess the question can be summed up as follows: How do you determine the event to hook to when the user clicks a certain button? How do you get the value displayed by a Win32 control at the time the button is clicked?

    Read the article

  • When developing a Microsoft Office Add-In (for Word), is it possible to store hidden metadata inform

    - by leftend
    I am trying to store metadata (basically a unique id) along with each cell of a table in a Word document. Currently, for the add-in I'm developing, I am querying the database, and building a table inside the Word document using the data that is retrieved. I want to be able to save any of the user's edits to the document, and persist it back to the database. My initial thought was to store a unique id along with each cell in the table so that I would be able to tell which records to update. I would also like to store some sort of "isChanged" flag within each cell so that I could tell which cells were changed. I found that I could add the needed information into the "ID" property of the cell - however, that information was not retained if the user saved the document, closed it, and re-opened it. I then tried storing the data by adding a data to the "Fields" collection - but that did not work and threw a runtime error. Here is the code that I tried: object t1 = Word.WdFieldType.wdFieldEmpty; object val = "myValue: " + counter; object preserveFormatting = true; tbl.Cell(i, j).Range.Fields.Add(tbl.Cell(i, j).Range, ref t1, ref val, ref preserveFormatting); This compiles fine, but throws this runtime error "This command is not available". So, is this possible at all? Or am I headed in the wrong direction? Thanks in advance.

    Read the article

  • Any way to run DLL's at button click C#

    - by Sandeep Bansal
    Hi Guys, I'm looking for ways to speed my program to the max and one way I thought of was to strip all DLL's being run at startup and run them when they need to be. As an example, I have a DLL containing info required for an update module, but I don't want to have that running in the program if I don't need it till I have an update. (I know I can create a separate program and link it to that but this is just an example.) Is there anyway to attach this on a button click? Sorry if I haven't made my question understandable. Thanks

    Read the article

  • Difference between jruby AOT classes with --java flag and without

    - by Johnathan Leppert
    When I compile a ruby file to a java class using jrubyc, I get different output when compiling with just jrubyc and with jrubyc --java (to generate the java file) and just javac. Why? Example: First Method: $ jrubyc --java myscript.rb $ javac -cp .:./jruby-complete.jar myscript.java Second Method: $ jrubyc myscript.rb I'd expect the generated classes to be exactly the same, but they're not. What's jrubyc doing under the covers? Thanks!

    Read the article

  • Send already generated MHTML using CDOSYS through C#?

    - by mutex
    I have a ready generated MHTML as a byte array (from Aspose.Words) and would like to send it as an email. I'm trying to do this through CDOSYS, though am open to other suggestions. For now though I have the following: CDO.Message oMsg = new CDO.Message(); CDO.IConfiguration iConfg = oMsg.Configuration; Fields oFields = iConfg.Fields; // Set configuration. Field oField = oFields["http://schemas.microsoft.com/cdo/configuration/sendusing"]; oField.Value = CDO.CdoSendUsing.cdoSendUsingPort; oField = oFields["http://schemas.microsoft.com/cdo/configuration/smtpserver"]; oField.Value = SmtpClient.Host; oField = oFields["http://schemas.microsoft.com/cdo/configuration/smtpserverport"]; oField.Value = SmtpClient.Port; oFields.Update(); //oMsg.CreateMHTMLBody("http://www.microsoft.com", CDO.CdoMHTMLFlags.cdoSuppressNone, "", ""); // NEED MAGIC HERE :) oMsg.Subject = warning.Subject; // string oMsg.From = "[email protected]"; oMsg.To = warning.EmailAddress; oMsg.Send(); In this snippet, the warning variable has a Body property which is a byte[]. Where it says "NEED MAGIC HERE" in the code above I want to use this byte[] to set the body of the CDO Message. I have tried the following, which unsurprisingly doesn't work: oMsg.HTMLBody = System.Text.Encoding.ASCII.GetString(warning.Body); Anybody have any ideas how I can achieve what I want with CDOSYS or something else?

    Read the article

  • Excel::Shape object getting released automatically after the count reaches 18 in List<T>

    - by A9S6
    I have a Excel addin written in C# 2.0 in which I am experiencing a strange behavior.Please note that this behavior is only seen in Excel 2003 and NOT in Excel 2007 or 2010. Issue: When the user clicks an import command button, a file is read and a number of Shapes are created/added to the worksheet using Worksheet::Shapes::AddPicture() method. A reference to these Shape objects are kept in a generic list: List<Excel.Shape> list = new List<Excel.Shape>(); Everything works fine till the list has less than 18 references. When the count reaches 18, and a new Shape reference is added, the first one i.e. @ index [0] is released. I am unable to call any method or property on that reference and calling a method/property throws a COMException (0x800A1A8) i.e. Object Required. If I add one more, then the reference @ [1] is not accessible and so on. Strange enough... this happens with Shape object only i.e. If I add one Shape and then 17 nulls to the list then this wont happen until 17 more Shape objects are added. Does anyone has an idea why it happens after the count reaches 18? I thought it might be something with the List's default capacity. Something like relocating the references during which they get released so I initialized it with a capacity of 1000 but still no luck. List<Excel.Shape> list = new List<Excel.Shape>(1000); Any Idea??

    Read the article

  • process tree

    - by Robert
    I'm looking for an easy way to find the process tree (as shown by tools like Process Explorer), in C# or other .Net language. It would also be useful to find the command-line arguments of another process (the StartInfo on System.Diagnostics.Process seems invalid for process other than the current process). I think these things can only be done by invoking the win32 api, but I'd be happy to be proved wrong. Thanks! Robert

    Read the article

  • Some basic COM question...

    - by smwikipedia
    I have just finished my first COM server DLL. And it runs smoothly. So I'd like to show my understanding for now and hear your critics. 1- How COM simply works? COM - "The Call Chain" COM Lib methods - Traditional DLL exports - Classes encapsulated in the COM DLL 2- With C++, the benefits like "interface" in OOP can only be taken advantage of at the source level. With COM, these benefits can be used at a binary level. 3- Some illustration about interface &pInterface ------- pInterface ---------- Interface----------------- methods Ixx ** Ixx * (method table) (void **) A Interface is a data structure in memory. It's nothing but a memory area containg a method table. Is my understanding alright? Thanks for your revision.

    Read the article

  • How to Instantiate ObjectFrame in VB.NET

    - by Suman
    I am trying to reach methods and properties of ObjectFrame through vb.net. But when I declared this as Dim objOLEObject As ObjectFrame and then trying to instantiate it as ObjOLEObject = New ObjectFrame it shows error like: "429: Retriveing the COM class factory for component with CLSID {3806e95d-e47c-11-cd-8701-00aa003f0f7} failed due to the following error: 80040154" To resolve this we re-installed both MS-Office 2003 and VS-2005, but could not get the solution. Could anyone suggest me how to declare and use this in vb.net? Thanks.

    Read the article

  • How to speed up 'cold start' of .NET component called from VB6 app

    - by Craig Johnston
    I have a VB6 app which brings up a form by invoking a .NET DLL, but the problem is that this form takes almost 5 seconds to appear after a menu item in the VB6 app is selected. How can I speed this up? I'm thinking that one possible solution is to load the Form from the .NET DLL during the splash screen of the VB6 app but make invisible or somehow not show it, and then when the menu item is selected I will make it show or visible. What are my options?

    Read the article

  • WinAPI magic (TCM_ADJUSTRECT message) and MONO runtime

    - by Luca
    I'm trying to get the same result of a .NET application (see the link Hide TabControl buttons to manage stacked Panel controls for details), but using the MONO runtime instead of the MS .NET runtime. Pratically, when the custom control is executed using the MONO runtime, the underlying message is not sent to the control, causing the tab pages to be shown... There is a portable solution which is elegant as the linked one? If it is not possible, what are possible workarounds (apart from removing/adding tabs at runtime)?

    Read the article

< Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >