Search Results

Search found 16598 results on 664 pages for 'device center'.

Page 160/664 | < Previous Page | 156 157 158 159 160 161 162 163 164 165 166 167  | Next Page >

  • ASP.NET MVC 4/Web API Single Page App for Mobile Devices ... Needs Authentication

    - by lmttag
    We have developed an ASP.NET MVC 4/Web API single page, mobile website (also using jQuery Mobile) that is intended to be accessed only from mobile devices (e.g., iPads, iPhones, Android tables and phones, etc.), not desktop browsers. This mobile website will be hosted internally, like an intranet site. However, since we’re accessing it from mobile devices, we can’t use Windows authentication. We still need to know which user (and their role) is logging in to the mobile website app. We tried simply using ASP.NET’s forms authentication and membership provider, but couldn’t get it working exactly the way we wanted. What we need is for the user to be prompted for a user name and password only on the first time they access the site on their mobile device. After they enter a correct user name and password and have been authenticated once, each subsequent time they access the site they should just go right in. They shouldn’t have to re-enter their credentials (i.e., something needs to be saved locally to each device to identify the user after the first time). This is where we had troubles. Everything worked as expected the first time. That is, the user was prompted to enter a user name and password, and, after doing that, was authenticated and allowed into the site. The problem is every time after the browser was closed on the mobile device, the device and user were not know and the user had to re-enter user name and password. We tried lots of things too. We tried setting persistent cookies in JavaScript. No good. The cookies weren’t there to be read the second time. We tried manually setting persistent cookies from ASP.NET. No good. We, of course, used FormsAuthentication.SetAuthCookie(model.UserName, true); as part of the form authentication framework. No good. We tried using HTML5 local storage. No good. No matter what we tried, if the user was on a mobile device, they would have to log in every single time. (Note: we’ve tried on an iPad and iPhone running both iOS 5.1 and 6.0, with Safari configure to allow cookies, and we’ve tried on Android 2.3.4.) Is there some trick to getting a scenario like this working? Or, do we have to write some sort of custom authentication mechanism? If so, how? And, what? Or, should we use something like claims-based authentication and WIF? Or??? Any help is appreciated. Thanks!

    Read the article

  • Keeping Velocity Constant and Player in Position - Sidescrolling

    - by user2904951
    I'm working on a Little Mobile Game with Cocos2D-X and Box2D. The Point where I got stuck is the movement of a box2d-body (the main actor) and the according Sprite. Now I want to : move this Body with a constant velocity along the x-axis, no matter if it's rolling (it's a circleshape) upwards or downwards keep the body nearly sticking to the ground on which it's rolling keep the Body and the according Sprite in the Center of the Screen. What I tried : in the update()- method I used body->SetLinearVelocity(b2Vec2(x,y)) to higher/lower values, if the Body was passing a constant value for his velocity I used to set very high y-Values in body->SetLinearVelocity(b2Vec2(x,y)) First tried to use CCFollow with my playerSprite, which was also Scrolling along the y-axis, as i only need to scroll along the x-axis, so I decided to move the whole layer which is containing the ambience (platforms etc.) to the left of my Screen and my Player Body & Player sprite to the right of the Screen, adjusting the speed values to Keep the Player in the Center of the Screen. Well... ...didn't work as i wanted it to, because each time i set the velocity manually (I also tried to use body->applyLinearImpulse(...) when the Body is moving upwards just as playing around with the value of velocityIterations in world->Step(...)) there's a small delay, which pushes the player Body more or less further of the Center of the Screen. ... didn't also work as I expected it to, because I needed to adjust the x-Values, when the Body was moving upwards to Keep it not getting slowed down, this made my Body even less sticky to the ground.... ... CCFollow did a good Job, except that I didn't want to scroll along the y-axis also and it Forces the overgiven sprite to start in the Center of the Screen. Moving the whole Layer even brought no good results, I have tried a Long time to adjust values of the movement Speed of the layer and the Body to Keep it negating each other, that the player stays nearly in the Center of the Screen.... So my question is : Does anyone of you have any Kind of new Approach for me to solve this cohesive bunch of Problems ? Cheers, Seb

    Read the article

  • Authenticating users in iPhone app

    - by Myron
    I'm developing an HTTP api for our web application. Initially, the primary consumer of the API will be an iPhone app we're developing, but I'm designing this with future uses in mind (such as mobile apps for other platforms). I'm trying to decide on the best way to authenticate users so they can access their accounts from the iPhone. I've got a design that I think works well, but I'm no security expert, so I figured it would be good to ask for feedback here. The design of the user authentication has 3 primary goals: Good user experience: We want to allow users to enter their credentials once, and remain logged in indefinitely, until they explicitly log out. I would have considered OAuth if not for the fact that the experience from an iPhone app is pretty awful, from what I've heard (i.e. it launches the login form in Safari, then tells the user to return to the app when authentication succeeds). No need to store the user creds with the app: I always hate the idea of having the user's password stored in either plain text or symmetrically encrypted anywhere, so I don't want the app to have to store the password to pass it to the API for future API requests. Security: We definitely don't need the intense security of a banking app, but I'd obviously like this to be secure. Overall, the API is REST-inspired (i.e. treating URLs as resources, and using the HTTP methods and status codes semantically). Each request to the API must include two custom HTTP headers: an API Key (unique to each client app) and a unique device ID. The API requires all requests to be made using HTTPS, so that the headers and body are encrypted. My plan is to have an api_sessions table in my database. It has a unique constraint on the API key and unique device ID (so that a device may only be logged into a single user account through a given app) as well as a foreign key to the users table. The API will have a login endpoint, which receives the username/password and, if they match an account, logs the user in, creating an api_sessions record for the given API key and device id. Future API requests will look up the api_session using the API key and device id, and, if a record is found, treat the request as being logged in under the user account referenced by the api_session record. There will also be a logout API endpoint, which deletes the record from the api_sessions table. Does anyone see any obvious security holes in this?

    Read the article

  • how to list out the submited data in same page where form submitted?

    - by OM The Eternity
    I have a form with 3 text values and one image.. I want to save these values such that i can display these records in the list below.. how can i do that... I am using osCommerce For example: <form method="post" id="fm-form" action ="" enctype="multipart/form-data"> <label>Name:</label> <input type="text" id="fm-name" name="fm-name" value="" /> <label>Email:</label> <input type="text" id="fm-email" name="fm-email" value="" /> <label>Birthdate:</label> <input type="text" id="fm-birthdate" name="fm-birthdate" value="" /> <input type="file" id="fm-image" name="fm-image"/> <input type="submit" id="fm-submit" value="Save it"> </form> <table width="100%" border="0" cellspacing="0" cellpadding="0"> <tr > <td align="center" class="productListing-heading">Product(s)</td> <td align="center" class="productListing-heading">Edit</td> <td align="center" class="productListing-heading">Delete</td> </tr> <?php for($i=0;$i<$count_image;$i++){?> <tr> <td align="left" class="productListing-data1"> <?php echo tep_image(DIR_WS_IMAGES . $file_realname, $save_image[$i], '110', '110');?> </td> <td align="center" class="productListing-data1">Edit</td> <td align="center" class="productListing-data1">Delete</td> </tr> <tr><td>&nbsp;</td></tr> <?php }?> </table> In the above format as the form is submitted the image has to be stored in a count_image array variable... and the on its count, the list below the form is displayed.. but i cannot get it worked.. could u pls help in doing this...

    Read the article

  • eth0 and eth1 both assigned same IP on boot

    - by Banjer
    I have a physical SLES 11 SP2 server on a Sun Fire x4140 that is giving me problems with networking upon reboot. The NICs are onboard. The networking appears successful during boot, but network services such as nfs fail hard. This is because eth0 and eth1 are both receiving the same configuration and are both ifup-ed. Once everything times out and I'm at the console, ifconfig shows that eth0 and eth1 are UP and running with the same IP. Attempting to ping anything in that subnet fails. Restarting the network service fixes the issue. eth0 is the correct NIC that should be configured as primary, per the MAC address. Question: Whats causing eth1 to be brought up with the same config as eth0?? I do not have a config script set up for eth1: banjer@harp:~> ls -la /etc/sysconfig/network/ total 104 drwxr-xr-x 6 root root 4096 Jun 11 12:21 . drwxr-xr-x 6 root root 4096 Apr 10 09:46 .. -rw-r--r-- 1 root root 13916 Apr 10 09:32 config -rw-r--r-- 1 root root 9952 Apr 10 09:36 dhcp -rw------- 1 root root 180 Jun 11 12:21 ifcfg-eth0 -rw------- 1 root root 180 Jun 11 12:21 ifcfg-eth3 -rw------- 1 root root 172 Feb 1 08:32 ifcfg-lo -rw-r--r-- 1 root root 29333 Feb 1 08:32 ifcfg.template drwxr-xr-x 2 root root 4096 Apr 10 09:32 if-down.d -rw-r--r-- 1 root root 239 Feb 1 08:32 ifroute-lo drwxr-xr-x 2 root root 4096 Apr 10 09:33 if-up.d drwx------ 2 root root 4096 May 5 2010 providers -rw-r--r-- 1 root root 25 Nov 16 2010 routes drwxr-xr-x 2 root root 4096 Apr 10 09:36 scripts On a side note, eth3 is also configured with an IP in a different subnet, but this has not posed any problems. FYI the kernel module being used is forcedeth. banjer@harp:~> sudo cat /etc/sysconfig/network/ifcfg-eth0 BOOTPROTO='static' BROADCAST='' ETHTOOL_OPTIONS='' IPADDR='172.21.64.25/20' MTU='' NAME='MCP55 Ethernet' NETWORK='' REMOTE_IPADDR='' STARTMODE='auto' USERCONTROL='no' ONBOOT="yes" Here's eth3 in case you need to see it: banjer@harp:~> sudo cat /etc/sysconfig/network/ifcfg-eth3 BOOTPROTO='static' BROADCAST='' ETHTOOL_OPTIONS='' IPADDR='172.11.200.4/24' MTU='' NAME='MCP55 Ethernet' NETWORK='' REMOTE_IPADDR='' STARTMODE='auto' USERCONTROL='no' ONBOOT="yes" Perhaps is something related to udev? 70-persistent-net-rules looks OK to me, but I may not understand it completely. banjer@harp:~> cat /etc/udev/rules.d/70-persistent-net.rules # This file was automatically generated by the /lib/udev/write_net_rules # program, run by the persistent-net-generator.rules rules file. # # You can modify it, as long as you keep each rule on a single # line, and change only the value of the NAME= key. # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4c", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth2" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4a", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth0" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4b", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth1" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4d", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth3" # PCI device 0x1077:0x3032 (qla3xxx) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:c1:dd:0e:34:6c", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth4" Any other thoughts on what would cause this?

    Read the article

  • How do you re-mount an ext3 fs readwrite after it gets mounted readonly from a disk error?

    - by cagenut
    Its a relatively common problem when something goes wrong in a SAN for ext3 to detect the disk write errors and remount the filesystem read-only. Thats all well and good, only when the SAN is fixed I can't figure out how to re-re-mount the filesystem read-write without rebooting. Behold: [root@localhost ~]# multipath -ll mpath0 (36001f93000a310000299000200000000) dm-2 XIOTECH,ISE1400 [size=1.1T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=2][active] \_ 1:0:0:1 sdb 8:16 [active][ready] \_ 2:0:0:1 sdc 8:32 [active][ready] [root@localhost ~]# mount /dev/mapper/mpath0 /mnt/foo [root@localhost ~]# touch /mnt/foo/blah All good, now I yank the LUN out from under it. [root@localhost ~]# touch /mnt/foo/blah [root@localhost ~]# touch /mnt/foo/blah touch: cannot touch `/mnt/foo/blah': Read-only file system [root@localhost ~]# tail /var/log/messages Mar 18 13:17:33 localhost multipathd: sdb: tur checker reports path is down Mar 18 13:17:34 localhost multipathd: sdc: tur checker reports path is down Mar 18 13:17:35 localhost kernel: Aborting journal on device dm-2. Mar 18 13:17:35 localhost kernel: Buffer I/O error on device dm-2, logical block 1545 Mar 18 13:17:35 localhost kernel: lost page write due to I/O error on dm-2 Mar 18 13:17:36 localhost kernel: ext3_abort called. Mar 18 13:17:36 localhost kernel: EXT3-fs error (device dm-2): ext3_journal_start_sb: Detected aborted journal Mar 18 13:17:36 localhost kernel: Remounting filesystem read-only It only thinks its read-only, in reality its not even there. [root@localhost ~]# multipath -ll sdb: checker msg is "tur checker reports path is down" sdc: checker msg is "tur checker reports path is down" mpath0 (36001f93000a310000299000200000000) dm-2 XIOTECH,ISE1400 [size=1.1T][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][enabled] \_ 1:0:0:1 sdb 8:16 [failed][faulty] \_ 2:0:0:1 sdc 8:32 [failed][faulty] [root@localhost ~]# ll /mnt/foo/ ls: reading directory /mnt/foo/: Input/output error total 20 -rw-r--r-- 1 root root 0 Mar 18 13:11 bar How it still remembers that 'bar' file being there... mystery, but not important right now. Now I re-present the LUN: [root@localhost ~]# tail /var/log/messages Mar 18 13:23:58 localhost multipathd: sdb: tur checker reports path is up Mar 18 13:23:58 localhost multipathd: 8:16: reinstated Mar 18 13:23:58 localhost multipathd: mpath0: queue_if_no_path enabled Mar 18 13:23:58 localhost multipathd: mpath0: Recovered to normal mode Mar 18 13:23:58 localhost multipathd: mpath0: remaining active paths: 1 Mar 18 13:23:58 localhost multipathd: dm-2: add map (uevent) Mar 18 13:23:58 localhost multipathd: dm-2: devmap already registered Mar 18 13:23:59 localhost multipathd: sdc: tur checker reports path is up Mar 18 13:23:59 localhost multipathd: 8:32: reinstated Mar 18 13:23:59 localhost multipathd: mpath0: remaining active paths: 2 Mar 18 13:23:59 localhost multipathd: dm-2: add map (uevent) Mar 18 13:23:59 localhost multipathd: dm-2: devmap already registered [root@localhost ~]# multipath -ll mpath0 (36001f93000a310000299000200000000) dm-2 XIOTECH,ISE1400 [size=1.1T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=2][enabled] \_ 1:0:0:1 sdb 8:16 [active][ready] \_ 2:0:0:1 sdc 8:32 [active][ready] Great right? It says [rw] right there. Not so fast: [root@localhost ~]# touch /mnt/foo/blah touch: cannot touch `/mnt/foo/blah': Read-only file system OK, doesn't do it automatically, I'll just give it a little push: [root@localhost ~]# mount -o remount /mnt/foo mount: block device /dev/mapper/mpath0 is write-protected, mounting read-only Noooooooooo. I have tried all sorts of different mount/tune2fs/dmsetup commands and I cannot figure out how to get it to un-flag the block device as write-protected. Rebooting will fix it, but I'd much rather do it on-line. An hour of googling has gotten me nowhere either. Save me ServerFault.

    Read the article

  • Bridged virtual interface is not available or visible to ifconfig.

    - by Omniwombat
    Hello all. I'm running Ubuntu 9.04, kernel 2.6.28-18, and vmware-server 2.0.1. I'm attempting to setup a virtual linux machine to use a bridged interface rather than NAT or host-only. Both NAT and host-only work just fine. When running vmware-config.pl, I set /dev/vmnet0 to bridge eth0, /dev/vmnet1 to host-only, and /dev/vmnet8 to NAT. When I run ifconfig -a I see the physical interface (eth0), vmnet1 and vmnet8 both of which are up and have IP addresses assigned to them. I also see other various interfaces that are not relevant here. In the web console, when I ask that the guest machine's network card be bridged, it states that a bridged setup is "Not available" and shows the disabled device icon. Inside the guest machine, I do have an eth0 interface which I can set to anything I like, however it can't see my external network, or the host. I do see errors in my vmware/hostd.log which state: "The network bridge on device vmnet0 is not running. The virtual machine will not be able to communicate with the host or with other machines on your network" which confirms the problem. vmnet-bridge is running, and I see the following in my process table: /usr/bin/vmnet-bridge -d /var/run/vmnet-bridge-0.pid -n 0 -i eth0 I confirm that the /var/run/vmnet-bridge-0.pid file is there and that it points to the correct process. I saw this question relating to Ubuntu 9.04 and bridged interfaces, in which the poster determined that the vsock library was not getting built due to a flaw in the vmware-config.pl script. I applied the patch, reran the script, and confirm that vsock.ko and vsock.o are in my /lib directory structure. vsock does show up in an lsmod. My /etc/vmware directory has /vmnet1 and /vmnet8 subdirectories. They contain configuration utilities for running DHCP and nat type services as expected. There is no vmnet0 subdirectory. My /etc/vmware/netmap.conf file DOES show entries for vmnet0; both the name and the device as I configured it from the script. My /dev directory contains devices vmnet0 through vmnet9. They have major device number 119, and minor device numbers 0 through 9. /proc/net/dev shows statistics for vmnet1 and vmnet8, but not vmnet0. I have a /proc/vmnet directory, but it's empty. When I start or stop the vmware service with /etc/init.d/vmware start, I see the following: Starting VMware services: Virtual machine monitor done Virtual machine communication interface done VM communication interface socket family: done Virtual ethernet done Bridged networking on /dev/vmnet0 done Host-only networking on /dev/vmnet1 (background) done DHCP server on /dev/vmnet1 done Host-only networking on /dev/vmnet8 (background) done DHCP server on /dev/vmnet8 done NAT service on /dev/vmnet8 done VMware Server Authentication Daemon (background) done Shared Memory Available done Starting VMware management services: VMware Server Host Agent (background) done VMware Virtual Infrastructure Web Access Starting VMware autostart virtual machines: Virtual machines done Nothing appears to be wrong there. What n00b thing am I doing such that vmnet0 and only vmnet0 does not show up in the interface list?

    Read the article

  • XFS disk becomes unavailable after a while

    - by Guard
    Ubuntu 12.04 (but the same was on 11.10 before upgrading) WD MyBook, 2TB, no RAID (or RAID0, not completely sure, anyway no mirroring, both 1TB disks are in use, mounted as a single device). Formatted to XFS, normally used for big movie files. Connected to Firewire 800. At some point the LED started going up and down as when constantly reading/writing. The device gives access error. When unplugged (cable, then holding the power button for a while, then unplugging the power) and re-connected becomes available. xfs_check with no results. xfs_repair did something, but looks like didn't fix any error. Then after a massive read (checking 1.5GB torrent file for integrity) becomes unavailable again. Any ideas what's wrong? Drives? Cables? Motherboard? OS? UPD: not sure how relevant this is, but here are dmesg output [14380.632816] SGI XFS with ACLs, security attributes, realtime, large block/inode numbers, no debug enabled [14380.633356] SGI XFS Quota Management subsystem [14421.812220] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14441.890596] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14441.896858] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14453.895347] firewire_core: created device fw1: GUID 0090a99500a35518, S400, 9 config ROM retries [14453.904818] scsi6 : SBP-2 IEEE-1394 [14453.905014] scsi7 : SBP-2 IEEE-1394 [14454.139993] firewire_sbp2: fw1.0: logged in to LUN 0000 (0 retries) [14454.158769] scsi 6:0:0:0: Direct-Access WD My Book 1015 PQ: 0 ANSI: 4 [14454.159251] sd 6:0:0:0: Attached scsi generic sg3 type 0 [14454.162391] firewire_sbp2: fw1.1: logged in to LUN 0001 (0 retries) [14454.167453] sd 6:0:0:0: [sdc] 3907017568 512-byte logical blocks: (2.00 TB/1.81 TiB) [14454.178822] sd 6:0:0:0: [sdc] Write Protect is off [14454.178826] sd 6:0:0:0: [sdc] Mode Sense: 10 00 00 00 [14454.186830] scsi 7:0:0:1: Enclosure WD My Book Device 1015 PQ: 0 ANSI: 4 [14454.186995] scsi 7:0:0:1: Attached scsi generic sg4 type 13 [14454.190078] sd 6:0:0:0: [sdc] Cache data unavailable [14454.190087] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.202176] sd 6:0:0:0: [sdc] Cache data unavailable [14454.202185] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.239940] sdc: [mac] sdc1 sdc2 sdc3 sdc4 [14454.271262] sd 6:0:0:0: [sdc] Cache data unavailable [14454.271270] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.271354] sd 6:0:0:0: [sdc] Attached SCSI disk [14454.272149] ses 7:0:0:1: Attached Enclosure device [14606.090024] XFS (sdc3): Mounting Filesystem [14612.048343] XFS (sdc3): Starting recovery (logdev: internal) [14620.697636] XFS (sdc3): Ending recovery (logdev: internal) [14748.120957] e1000e: eth0 NIC Link is Up 100 Mbps Full Duplex, Flow Control: Rx/Tx [14748.120963] e1000e 0000:00:19.0: eth0: 10/100 speed: disabling TSO [14752.568382] uhci_hcd 0000:00:1a.0: PCI INT A disabled [14752.568579] uhci_hcd 0000:00:1a.1: PCI INT B disabled [14752.568738] ehci_hcd 0000:00:1a.7: PCI INT C disabled [14752.568779] ehci_hcd 0000:00:1a.7: PME# enabled [14752.584526] uhci_hcd 0000:00:1d.1: PCI INT B disabled [14752.584689] uhci_hcd 0000:00:1d.2: PCI INT C disabled [14752.680079] ehci_hcd 0000:00:1a.7: BAR 0: set to [mem 0xe4641000-0xe46413ff] (PCI address [0xe4641000-0xe46413ff]) [14752.680104] ehci_hcd 0000:00:1a.7: restoring config space at offset 0xf (was 0x300, writing 0x30b) [14752.680136] ehci_hcd 0000:00:1a.7: restoring config space at offset 0x1 (was 0x2900000, writing 0x2900002) [14752.680170] ehci_hcd 0000:00:1a.7: PME# disabled [14752.680182] ehci_hcd 0000:00:1a.7: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [14752.680190] ehci_hcd 0000:00:1a.7: setting latency timer to 64 [14752.710334] uhci_hcd 0000:00:1a.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [14752.710342] uhci_hcd 0000:00:1a.0: setting latency timer to 64 [14752.749186] uhci_hcd 0000:00:1a.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [14752.749194] uhci_hcd 0000:00:1a.1: setting latency timer to 64 [14752.790231] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 22 (level, low) -> IRQ 22 [14752.790239] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [14752.829170] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [14752.829178] uhci_hcd 0000:00:1d.2: setting latency timer to 64

    Read the article

  • Bonding: works only for download

    - by Crazy_Bash
    I would like to install bonding with 4 links with mode 4. but only "download/receiving" works with bondig. for transmitting the system chooses one link. ifconfig bond0 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 inet addr:ip Bcast:ip Mask:255.255.255.248 inet6 addr: fe80::92e2:baff:fe0f:76b4/64 Scope:Link UP BROADCAST RUNNING MASTER MULTICAST MTU:1500 Metric:1 RX packets:239187413 errors:0 dropped:10944 overruns:0 frame:0 TX packets:536902370 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:14688536197 (13.6 GiB) TX bytes:799521192901 (744.6 GiB) eth2 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:54969488 errors:0 dropped:0 overruns:0 frame:0 TX packets:2537 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3374778591 (3.1 GiB) TX bytes:314290 (306.9 KiB) eth3 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:64935805 errors:0 dropped:1 overruns:0 frame:0 TX packets:2532 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3993499746 (3.7 GiB) TX bytes:313968 (306.6 KiB) eth4 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:57352105 errors:0 dropped:2 overruns:0 frame:0 TX packets:536894778 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3524236530 (3.2 GiB) TX bytes:799520265627 (744.6 GiB) eth5 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:61930025 errors:0 dropped:3 overruns:0 frame:0 TX packets:2540 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3796021948 (3.5 GiB) TX bytes:314274 (306.9 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:62 errors:0 dropped:0 overruns:0 frame:0 TX packets:62 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:5320 (5.1 KiB) TX bytes:5320 (5.1 KiB) those are my configs: DEVICE="eth2" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE="eth3" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE="eth4" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE="eth5" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE=bond0 IPADDR=<ip> BROADCAST=<ip> NETWORK=<ip> GATEWAY=<ip> NETMASK=<ip> USERCTL=no BOOTPROTO=none ONBOOT=yes NM_CONTROLLED=no cat /proc/net/bonding/bond0 Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011) Bonding Mode: IEEE 802.3ad Dynamic link aggregation Transmit Hash Policy: layer2 (0) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 802.3ad info LACP rate: slow Aggregator selection policy (ad_select): stable Active Aggregator Info: Aggregator ID: 1 Number of ports: 4 Actor Key: 17 Partner Key: 11 Partner Mac Address: 00:24:51:12:63:00 Slave Interface: eth2 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b4 Aggregator ID: 1 Slave queue ID: 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b5 Aggregator ID: 1 Slave queue ID: 0 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b6 Aggregator ID: 1 Slave queue ID: 0 Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b7 Aggregator ID: 1 Slave queue ID: 0 /etc/modprobe.d/bonding.conf alias bond0 bonding options bond0 mode=4 miimon=100 updelay=200 #downdelay=200 xmit_hash_policy=layer3+4 lacp_rate=1 Linux: Linux 3.0.0+ #1 SMP Fri Oct 26 07:55:47 EEST 2012 x86_64 x86_64 x86_64 GNU/Linux what i've tried: downdelay=200 xmit_hash_policy=layer3+4 lacp_rate=1 mode 6

    Read the article

  • Can't re-mount existing RAID10 on Ubuntu

    - by Zoran
    I saw similar questions, but didn't find what solution to my problem. After power-cut, one of RAID10 (4 disks were) appears to be malfunctioning. I make tha array active one, but can not mount it. Always the same error: mount: you must specify the filesystem type So, here is what I have when type mdadm --detail /dev/md0 /dev/md0: Version : 00.90.03 Creation Time : Tue Sep 1 11:00:40 2009 Raid Level : raid10 Array Size : 1465148928 (1397.27 GiB 1500.31 GB) Used Dev Size : 732574464 (698.64 GiB 750.16 GB) Raid Devices : 4 Total Devices : 3 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Mon Jun 11 09:54:27 2012 State : clean, degraded Active Devices : 3 Working Devices : 3 Failed Devices : 0 Spare Devices : 0 Layout : near=2, far=1 Chunk Size : 64K UUID : 1a02e789:c34377a1:2e29483d:f114274d Events : 0.166 Number Major Minor RaidDevice State 0 8 16 0 active sync /dev/sdb 1 0 0 1 removed 2 8 48 2 active sync /dev/sdd 3 8 64 3 active sync /dev/sde At the /etc/mdadm/mdadm.conf I have by default, scan all partitions (/proc/partitions) for MD superblocks. alternatively, specify devices to scan, using wildcards if desired. DEVICE partitions auto-create devices with Debian standard permissions CREATE owner=root group=disk mode=0660 auto=yes automatically tag new arrays as belonging to the local system HOMEHOST <system> instruct the monitoring daemon where to send mail alerts MAILADDR root definitions of existing MD arrays ARRAY /dev/md0 level=raid10 num-devices=4 UUID=1a02e789:c34377a1:2e29483d:f114274d ARRAY /dev/md1 level=raid1 num-devices=2 UUID=9b592be7:c6a2052f:2e29483d:f114274d This file was auto-generated... So, my question is, how can I mount md0 array (md1 has been mounted without problem) in order to preserve existing data? One more thing, fdisk -l command gives the following result: Disk /dev/sdb: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x660a6799 Device Boot Start End Blocks Id System /dev/sdb1 * 1 88217 708603021 83 Linux /dev/sdb2 88218 91201 23968980 5 Extended /dev/sdb5 88218 91201 23968948+ 82 Linux swap / Solaris Disk /dev/sdc: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x0008f8ae Device Boot Start End Blocks Id System /dev/sdc1 1 88217 708603021 83 Linux /dev/sdc2 88218 91201 23968980 5 Extended /dev/sdc5 88218 91201 23968948+ 82 Linux swap / Solaris Disk /dev/sdd: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x4be1abdb Device Boot Start End Blocks Id System Disk /dev/sde: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xa4d5632e Device Boot Start End Blocks Id System Disk /dev/sdf: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xdacb141c Device Boot Start End Blocks Id System Disk /dev/sdg: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xdacb141c Device Boot Start End Blocks Id System Disk /dev/md1: 750.1 GB, 750156251136 bytes 2 heads, 4 sectors/track, 183143616 cylinders Units = cylinders of 8 * 512 = 4096 bytes Disk identifier: 0xdacb141c Device Boot Start End Blocks Id System Warning: ignoring extra data in partition table 5 Warning: ignoring extra data in partition table 5 Warning: ignoring extra data in partition table 5 Warning: invalid flag 0x7b6e of partition table 5 will be corrected by w(rite) Disk /dev/md0: 1500.3 GB, 1500312502272 bytes 255 heads, 63 sectors/track, 182402 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x660a6799 Device Boot Start End Blocks Id System /dev/md0p1 * 1 88217 708603021 83 Linux /dev/md0p2 88218 91201 23968980 5 Extended /dev/md0p5 ? 121767 155317 269488144 20 Unknown And one more thing. When using mdadm --examine command, here ise result: mdadm -v --examine --scan /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sd ARRAY /dev/md1 level=raid1 num-devices=2 UUID=9b592be7:c6a2052f:2e29483d:f114274d devices=/dev/sdf ARRAY /dev/md0 level=raid10 num-devices=4 UUID=1a02e789:c34377a1:2e29483d:f114274d devices=/dev/sdb,/dev/sdc,/dev/sdd,/dev/sde md0 has 3 devices which are active. Can someone instruct me how to solve this issue? If it is possible, I would like not to removing faulty HDD. Please advise

    Read the article

  • "ID 046d:c50e Logitech, Inc. Cordless Mouse Receiver" wheel-click is wrong

    - by sputnick
    I use this mouse under archlinux x86_64 with 3.2.8-1-ARCH kernel. I have some problems to select and then paste with the wheel-click in some applications like konversation, not in a terminal nor an editor. I don't know if it's a hardware problem or a software one. $ lsusb -v Bus 002 Device 110: ID 046d:c50e Logitech, Inc. Cordless Mouse Receiver Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 8 idVendor 0x046d Logitech, Inc. idProduct 0xc50e Cordless Mouse Receiver bcdDevice 25.10 iManufacturer 1 Logitech iProduct 2 USB RECEIVER iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 34 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xa0 (Bus Powered) Remote Wakeup MaxPower 70mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 1 Boot Interface Subclass bInterfaceProtocol 2 Mouse iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.11 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 95 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 10 Device Status: 0x0000 (Bus Powered) When I see what's happens in xev, the output is different compared to another mouse My buggy Logitech mouse : ButtonPress event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x4400002, time 170350700, (48,52), root:(1491,75), state 0x10, button 11, same_screen YES EnterNotify event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x0, time 170350700, (48,52), root:(1491,75), mode NotifyGrab, detail NotifyInferior, same_screen YES, focus YES, state 16 KeymapNotify event, serial 40, synthetic NO, window 0x0, keys: 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ButtonPress event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x4400002, time 170350716, (48,52), root:(1491,75), state 0x10, button 6, same_screen YES ButtonRelease event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x4400002, time 170350716, (48,52), root:(1491,75), state 0x10, button 6, same_screen YES ButtonRelease event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x4400002, time 170350988, (48,52), root:(1491,75), state 0x10, button 11, same_screen YES LeaveNotify event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x0, time 170350988, (48,52), root:(1491,75), mode NotifyUngrab, detail NotifyInferior, same_screen YES, focus YES, state 16 a working mouse (dell) : ButtonPress event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x4400002, time 170245131, (46,32), root:(1489,55), state 0x10, button 2, same_screen YES EnterNotify event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x0, time 170245131, (46,32), root:(1489,55), mode NotifyGrab, detail NotifyInferior, same_screen YES, focus YES, state 528 KeymapNotify event, serial 40, synthetic NO, window 0x0, keys: 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ButtonRelease event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x4400002, time 170245411, (46,32), root:(1489,55), state 0x210, button 2, same_screen YES LeaveNotify event, serial 40, synthetic NO, window 0x4400001, root 0x15a, subw 0x0, time 170245411, (46,32), root:(1489,55), mode NotifyUngrab, detail NotifyInferior, same_screen YES, focus YES, state 16 A demo of the problem when I use konversation (IRC) : http://www.youtube.com/watch?v=lhmr92M7NCc I tried to modify the button map with xmodmap like this with no success (one at a time) : xmodmap -e "pointer = 1 0 3" xmodmap -e "pointer = 1 1 3" xmodmap -e "pointer = 1 2 3" xmodmap -e "pointer = 1 3 3" xmodmap -e "pointer = 1 4 3" xmodmap -e "pointer = 1 5 3" xmodmap -e "pointer = 1 6 3" xmodmap -e "pointer = 1 7 3" xmodmap -e "pointer = 1 8 3" xmodmap -e "pointer = 1 9 3" xmodmap -e "pointer = 1 10 3" xmodmap -e "pointer = 1 11 3" xmodmap -e "pointer = 1 12 3" xmodmap -e "pointer = 1 13 3" xmodmap -e "pointer = 1 14 3" xmodmap -e "pointer = 1 15 3" xmodmap -e "pointer = 1 16 3" xmodmap -e "pointer = 1 17 3" xmodmap -e "pointer = 1 18 3" xmodmap -e "pointer = 1 19 3" xmodmap -e "pointer = 1 20 3" xmodmap -e "pointer = 1 21 3" xmodmap -e "pointer = 1 22 3" xmodmap -e "pointer = 1 23 3" xmodmap -e "pointer = 1 24 3" xmodmap -e "pointer = 1 25 3" Any clue ? I would like to avoid buying a new mouse just for a paste problem.

    Read the article

  • Network config / gear question

    - by mcgee1234
    I have been tasked with setting up a fairly straightforward rack in a data center (we do not even need a whole rack, but this is the smallest allotment available). In a nutshell, 4 to 6 servers need to be able to reach 2 (maybe 3) vendors. The servers needs to be reachable over the internet. A little more detail - the networks the servers need to reach are inside of the data center, and are "trusted". Connections to these networks will be achieved through intra data center cross connects. It is kind of like a manufacturing line where we receive data from one vendor (burst-able up to 200 Mbits), churn through it on the servers, and then send out data to another vendor (bursts up to 20 Mbits). This series of events is very latency sensitive, so much so that it is common practice not to use NAT or a firewall on these segments (or so I hear). To reach the servers over the internet, I plan to use a site to site VPN. (This part is only relevant as far as hardware selection goes). I have 2 configurations in mind: Cisco 2911 (2921) (with the additional wan ports module) and a layer 2 switch - in this scenario, I would use the router also for VPN. Cisco 3560 layer 3 switch to interconnect the networks inside of the data center and an ASA 5510 (which is total overkill, but the 5505 is not rack mountable) as a firewall for the Wan side (internet) and VPN. I envision the setup to be as follows: Internet - ASA - 3560 Vendors - 3560 - Servers The general idea is that the ASA acts as a firewall and VPN device and the 3560 does all the heavy lifting. The first is a fairly traditional setup but my concern is performance. The second is somewhat unorthodox in that the vendors are directly connected to the layer 3 switch without passing through a firewall. Based on my understanding however, a layer 3 switch will perform substantially better as it will do hardware (ASIC) vs. software switching. (Note that number 2 is a little over the budget, but not unworkable (double negative, ugh)) Since this is my first time dealing with a data center, I am not sure what the IP space is going to look like. I suspect I will retain a block(s) of public IPs, vlan them to individual interfaces for the vendor connections and the servers (which will not reachable from the wan side of course) and setup routing on the switch. So here are my questionss: Is there a substantial performance difference between 1 and 2, i.e. hardware based switching on a layer 3 vs a software base on the 2911? I have trolled the internet and found a lot of Cisco literature, but nothing that I could really use to get a good handle. The vendors we connect to are secure and trusted (famous last words) and as I understand it, it is common practice not to NAT or firewall these connections (because of the aforementioned latency sensitivity). But what what kind of latency are we really talking about if I push the data through a router (or even ASA for that matter)? For our purposes, 5 ms will not kill us, 20 or 30 can be very costly. Others measure in microseconds, but they are out of our league. Is there any issues with using public IPs on a layer 3 switch? I am certainly not married to either of these configs, and I am totally open to any ideas. My knowledge (and I use the term loosely) is largely from books so I welcome any advice / insight. Thanks in advance.

    Read the article

  • PowerShell Control over Nikon D3000 Camera

    My wife got me a Nikon D3000 camera for Christmas last year, and Im loving it but still trying to wrap my head around some of its features.  For instance, when you plug it into a computer via USB, it doesnt show up as a drive like most cameras Ive used to, but rather it shows up as Computer\D3000.  After a bit of research, Ive learned that this is because it implements the MTP/PTP protocol, and thus doesnt actually let Windows mount the cameras storage as a drive letter.  Nikon describes the use of the MTP and PTP protocols in their cameras here. What Im really trying to do is gain access to the cameras file system via PowerShell.  Ive been using a very handy PowerShell script to pull pictures off of my cameras and organize them into folders by date.  Id love to be able to do the same thing with my Nikon D3000, but so far I havent been able to figure out how to get access to the files in PowerShell.  If you know, Id appreciate any links/tips you can provide.  All I could find is a shareware product called PTPdrive, which Im not prepared to shell out money for (yet).  (and yes you can do much the same thing with Windows 7s Import Pictures and Videos wizard, which is pretty good too) However, in my searching, I did find some really cool stuff you can do with PowerShell and one of these cameras, like actually taking pictures via PowerShell commands.  Credit for this goes to James ONeill and Mark Wilson.  Heres what I was able to do: Taking Pictures via PowerShell with D3000 First, connect your camera, turn it on, and launch PowerShell.  Execute the following commands to see what commands your device supports.  $dialog = New-Object -ComObject "WIA.CommonDialog" $device = $dialog.ShowSelectDevice() $device.Commands You should see something like this: Now, to take a picture, simply point your camera at something and then execute this command: $device.ExecuteCommand("{AF933CAC-ACAD-11D2-A093-00C04F72DC3C}") .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; } Imagine my surprise when this actually took a picture (with auto-focus): Imagine what you could do with a camera completely under the control of your computer  Time-lapse photography would be pretty simple, for instance, with a very simple loop that takes a picture and then sleeps for a minute (or whatever time period).  Hooked up to a laptop for portability (and an A/C power supply), this would be pretty trivial to implement.  I may have to give it a shot and report back. Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Surface Review from Canadian Guy Who Didn&rsquo;t Go To Build

    - by D'Arcy Lussier
    I didn’t go to Build last week, opted to stay home and go trick-or-treating with my daughters instead. I had many friends that did go however, and I was able to catch up with James Chambers last night to hear about the conference and play with his Surface RT and Nokia 920 WP8 devices. I’ve been using Windows 8 for a while now, so I’m not going to comment on OS features – lots of posts out there on that already. Let me instead comment on the hardware itself. Size and Weight The size of the tablet was awesome. The Windows 8 tablet I’m using to reference this against is the one from Build 2011 (Samsung model) we received as well as my iPad. The Surface RT was taller and slightly heavier than the iPad, but smaller and lighter than the Samsung Win 8 tablet. I still don’t prefer the default wide-screen format, but the Surface RT is much more usable even when holding it by the long edge than the Samsung. Build Quality No issues with the build quality, it seemed very solid. But…y’know, people have been going on about how the Surface RT materials are so much better than the plastic feeling models Samsung and others put out. I didn’t really notice *that* much difference in that regard with the Surface RT. Interesting feature I didn’t expect – the Windows button on the device is touch-sensitive, not a mechanical one. I didn’t try video or anything, so I can’t comment on the media experience. The kickstand is a great feature, and the way the Surface RT connects to the combo case/keyboard touchcover is very slick while being incredibly simple. What About That Touch Cover Keyboard? So first, kudos to Microsoft on the touch cover! This thing was insanely responsive (including the trackpad) and really delivered on the thinness I was expecting. With that said, and remember this is with very limited use, I would probably go with the Type Cover instead of the Touch Cover. The difference is buttons. The Touch Cover doesn’t actually have “buttons” on the keyboard – hence why its a “touch” cover. You tap on a key to type it. James tells me after a while you get used to it and you can type very fast. For me, I just prefer the tactile feeling of a button being pressed/depressed. But still – typing on the touch case worked very well. Would I Buy One? So after playing with it, did I cry out in envy and rage that I wasn’t able to get one of these machines? Did I curse my decision to collect Halloween candy with my kids instead of being at Build getting hardware? Well – no. Even with the keyboard, the Surface RT is not a business laptop replacement device. While Office does come included, you can’t install any other applications outside of Windows Store Apps. This might be limiting depending on what other applications you need to have available on your computer. Surface RT is a great personal computing device, as long as you’re not already invested in a competing ecosystem. I’ve heard people make statements that they’re going to replace all the iPads in their homes with Surface tablets. In my home, that’s not feasible – my wife and daughters have amassed quite a collection of games via iTunes. We also buy all our music via iTunes as well, so even with the XBox streaming music service now available we’re still tied quite tightly to iTunes. So who is the Surface RT for? In my mind, if you’re looking for a solid, compact device that provides basic business functionality (read: email) or if you have someone that needs a very simple to use computer for email, web browsing, etc., then Surface RT is a great option. For me, I’m waiting on the Samsung Ativ Smart PC Pro and am curious to see what changes the Surface Pro will come with.

    Read the article

  • How to Sync Any Browser’s Bookmarks With Your iPad or iPhone

    - by Chris Hoffman
    Apple makes it easy to synchronize bookmarks between the Safari browser on a Mac and the Safari browser on iOS, but you don’t have to use Safari — or a Mac — to sync your bookmarks back and forth. You can do this with any browser. Whether you’re using Chrome, Firefox, or even Internet Explorer, there’s a way to sync your browser bookmarks so you can access your same bookmarks on your iPad. Safari on a Mac Apple’s iCloud service is the officially supported way to sync data with your iPad or iPhone. It’s included on Macs, but Apple also offers similar iCloud bookmark syncing features for Windows. On a Mac, this should be enabled by default. To check whether it’s enabled, you can launch the System Preferences panel on your Mac, open the iCloud preferences panel, and ensure the Safari option is checked. If you’re using Safari on Windows — well, you shouldn’t be. Apple is no longer updating Safari for Windows. iCloud allows you to synchronize bookmarks between other browsers on your Windows system and Safari on your iOS device, so Safari isn’t necessary. Internet Explorer, Firefox, or Chrome via iCloud To get started, download Apple’s iCloud Control Panel application for Windows and install it. Launch the iCloud Control Panel and log in with the same iCloud account (Apple ID) you use on your iPad or iPhone. You’ll be able to enable Bookmark syncing with Internet Explorer, Firefox, or Chrome. Click the Options button to select the browser you want to synchronize bookmarks with. (Note that bookmarks are called “favorites” in Internet Explorer.) You’ll be able to access your synced bookmarks in the Safari browser on your iPad or iPhone, and they’ll sync back and forth automatically over the Internet. Google Chrome Sync Google Chrome also has its own built-in sync feature and Google provides an official Chrome app for iPad and iPhone. If you’re a Chrome user, you can set up Chrome Sync on your desktop version of Chrome — you should already have this enabled if you have logged into your Chrome browser. You can check if this Chrome Sync is enabled by opening Chrome’s settings screen and seeing whether you’re signed in. Click the Advanced sync settings button and ensure bookmark syncing is enabled. Once you have Chrome Sync set up, you can install the Chrome app from the App Store and sign in with the same Google account. Your bookmarks, as well as other data like your open browser tabs, will automatically sync. This can be a better solution because the Chrome browser is available for so many platforms and you gain the ability to synchronize other browser data, such as your open browser tabs, between your devices. Unfortunately, the Chrome browser is slower than Apple’s own Safari browser on iPad and iPhone because of the way Apple limits third-party browsers, so using it involves a trade-off. Manual Bookmark Sync in iTunes iTunes also allows you to sync bookmarks between your computer and your iPad or iPhone. It does this the old-fashioned way, by initiating a manual sync when your device is plugged in via USB. To access this option, connect your device to your computer, select the device in iTunes, and click the Info tab. This is the more outdated way of synchronizing your bookmarks. This feature may be useful if you want to create a one-time copy of your bookmarks from your PC, but it’s nowhere near ideal for regular syncing. You don’t have to use this feature, just as you really don’t have to use iTunes anymore. In fact, this option is unavailable if you’ve set up iCloud syncing in iTunes. After you set up bookmark syncing via iCloud or Chrome Sync, bookmarks will sync immediately after you save, remove, or edit them.     

    Read the article

  • Restyling RadDataPager for WPF and Silverlight

      A small but powerful control has joined the great family of Telerik XAML controls with the recent release. RadDataPager is a result of an increasing demand from our customers who needed to work with large amounts of server data presented in small portions at the client side.  The primary goal was to make a powerful data paging control to be used in any scenarios requiring getting and presenting portions of data. How good is RadDataPager in working with paged data you can see in Rossen's announcement. Yet being a XAML control it challenged us with making one more visually appealing and highly customizable control. It offers a slick look in all available WPF/Silverlight Telerik themes:     As you can see the default design is targeting mainly business scenarios. At the same time being an example for a truly lookless XAML control RadDataPager allows restyling with minimal efforts this way widening the possible range of applications.  Lets see what we can doo with a few lines of XAML : <Style x:Key="buttonStyle" TargetType="ButtonBase" > <Setter Property="Template"> <Setter.Value> <ControlTemplate TargetType="ButtonBase"> <Grid Width="40" Background="Black"> <Ellipse StrokeThickness="2" VerticalAlignment="Center" Width="15" Height="15" HorizontalAlignment="Center" Fill="Gray" /> <Ellipse Visibility="{Binding IsCurrent, Converter={StaticResource VisibilityConverter}}" VerticalAlignment="Center" Height="16" Fill="White" HorizontalAlignment="Center" Width="16"/> </Grid> </ControlTemplate> </Setter.Value> </Setter> </Style> ... <telerik:RadDataPager NumericButtonStyle="{StaticResource buttonStyle}" ... And the result: The IPhone-style-thing bellow the RadCoverFlow is actually our RadDataPager.       With a few more lines of XAML we may get  almost any imaginable look of the pager control including the fascinating result demonstrated in the short video on the top.Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Creando un File Upload

    - by jaullo
    Para iniciar hablaremos un poco sobre el control File Upload, de esta forma daremos una idea general de que es y como trabaja. El File Upload es un control de asp.net que permite que los usuarios seleccionen un archivo de cualquier ubicación en el equipo y lo suban a un directorio predeterminado a traves de una página asp.net. En principio este control esta limitado para no permitir subir archivos de mas de 4 MB. Sin embargo, desde el webconfig de nuestra aplicacón podremos cambiar ese valor, ya sea para aumentarlo o bien para disminuirlo. Nuestro ejemplo, se enfocará en crear un webcontrol que permita seleccionar un archivo y guardarlo, asi que empecemos. Lo primero será agregar a nuestra página un webcontrol que llamaremos Upload.ascx Posteriormente en nuestro webcontrol, agregamos el siguiente código: <table style="width: 100%">         <tr>             <td colspan="3">             <div align="center">                  <asp:Label ID="Label1" runat="server" Text="File Upload"></asp:Label>              </div>             </td>                    </tr>         <tr>             <td style="width: 456px" rowspan="2">                                                             &nbsp;</td>             <td style="width: 386px">                                <div align="center">                         <asp:FileUpload ID="FileUpload1" runat="server" Height="24px" Width="243px" />                         <span id="Span1" runat="server" />                            </div>                      </td>             <td rowspan="2">                                                             </td>         </tr>         <tr>             <td style="width: 386px">                 <div align="center">                      <asp:ImageButton Id="btnupload" runat="server" OnClick="btnupload_Click"                     ImageUrl="~/Styles/img/upload.png" style="text-align: center" />           </div>                  </td>         </tr>         <tr>             <td colspan="3">                 &nbsp;</td>         </tr>     </table>  De esta forma nuestro control deberá verse algo así   Por último en el code behin de nuestro control agregamos el código a nuestro boton, el cual será el encargado de leer el archivo que se encuentra en el File Upload y guardarlo en la ruta especificada.  Protected Sub btnupload_Click(ByVal sender As Object, ByVal e As System.Web.UI.ImageClickEventArgs) Handles btnupload.Click         If FileUpload1.HasFile Then             Dim fileExt As String             fileExt = System.IO.Path.GetExtension(FileUpload1.FileName)             If (fileExt = ".exe") Then                 Label1.Text = "You can´t upload .exe file!"             Else                 Try                     FileUpload1.SaveAs(decrpath & _                        FileUpload1.FileName)                     Label1.Text = "File name: " & _                       FileUpload1.PostedFile.FileName & "<br>" & _                       "File Size: " & _                       FileUpload1.PostedFile.ContentLength & " kb<br>" & _                       "Content type: " & _                       FileUpload1.PostedFile.ContentType                 Catch ex As Exception                     Label1.Text = "ERROR: " & ex.Message.ToString()                 End Try             End If         Else             Label1.Text = "You have not specified a file!"         End If            End Sub   Como vemos en el código anterior tambien hemos agregado otros elementos los cuales nos dirán el nombre del archivo, el tipo de contenido y el tamaño en kb una vez que el archivo ha sido súbido al servidor. Por último deben tomar en cuenta que decrpath es la ruta en donde será subido el archivo, la cual deben variar a su gusto.

    Read the article

  • Using the Onboard VGA output with a PCIe video card. Both nVidia

    - by sebikul
    I have 2 video cards, one On board, a nVidia 6150SE nForce 430 and a PCIe nVidia GeForce GT 220 1GB DDR2 RAM I have already configured the PCIe card to use the dual monitor feature, using the VGA and HDMI ports, but now I want to add a third monitor, using the On board VGA port I have managed to enable the On board graphics processor, which is taking 400MB of ram, but I cant manage to use it, nvidia-settings does not detect it, like it's not usable (but is there) My questions are the following: How can I manage to get the On board VGA display to work together with the PCIe graphics card? If possible, how can I recover those 400 MB the on board card is taking (even without being used) or how can I get it to use the PCIe card available memory? System Details: Linux 2.6.35-28-generic i686 Ubuntu 10.10 (All updates installed) NVIDIA Driver Version: 260.19.06 (Official) If more info is needed please let me know. Here is the lspci output when the On board card is disabled: 00:00.0 RAM memory: nVidia Corporation MCP61 Memory Controller (rev a1) 00:01.0 ISA bridge: nVidia Corporation MCP61 LPC Bridge (rev a2) 00:01.1 SMBus: nVidia Corporation MCP61 SMBus (rev a2) 00:01.2 RAM memory: nVidia Corporation MCP61 Memory Controller (rev a2) 00:01.3 Co-processor: nVidia Corporation MCP61 SMU (rev a2) 00:02.0 USB Controller: nVidia Corporation MCP61 USB Controller (rev a3) 00:02.1 USB Controller: nVidia Corporation MCP61 USB Controller (rev a3) 00:04.0 PCI bridge: nVidia Corporation MCP61 PCI bridge (rev a1) 00:05.0 Audio device: nVidia Corporation MCP61 High Definition Audio (rev a2) 00:06.0 IDE interface: nVidia Corporation MCP61 IDE (rev a2) 00:07.0 Bridge: nVidia Corporation MCP61 Ethernet (rev a2) 00:08.0 IDE interface: nVidia Corporation MCP61 SATA Controller (rev a2) 00:09.0 PCI bridge: nVidia Corporation MCP61 PCI Express bridge (rev a2) 00:0b.0 PCI bridge: nVidia Corporation MCP61 PCI Express bridge (rev a2) 00:0c.0 PCI bridge: nVidia Corporation MCP61 PCI Express bridge (rev a2) 00:0d.0 VGA compatible controller: nVidia Corporation C61 [GeForce 6150SE nForce 430] (rev a2) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 01:09.0 Ethernet controller: Intel Corporation 82557/8/9/0/1 Ethernet Pro 100 (rev 08) 02:00.0 VGA compatible controller: nVidia Corporation GT216 [GeForce GT 220] (rev a2) 02:00.1 Audio device: nVidia Corporation High Definition Audio Controller (rev a1) And this is when both are enabled: 00:00.0 RAM memory: nVidia Corporation MCP61 Memory Controller (rev a1) 00:01.0 ISA bridge: nVidia Corporation MCP61 LPC Bridge (rev a2) 00:01.1 SMBus: nVidia Corporation MCP61 SMBus (rev a2) 00:01.2 RAM memory: nVidia Corporation MCP61 Memory Controller (rev a2) 00:01.3 Co-processor: nVidia Corporation MCP61 SMU (rev a2) 00:02.0 USB Controller: nVidia Corporation MCP61 USB Controller (rev a3) 00:02.1 USB Controller: nVidia Corporation MCP61 USB Controller (rev a3) 00:04.0 PCI bridge: nVidia Corporation MCP61 PCI bridge (rev a1) 00:05.0 Audio device: nVidia Corporation MCP61 High Definition Audio (rev a2) 00:06.0 IDE interface: nVidia Corporation MCP61 IDE (rev a2) 00:07.0 Bridge: nVidia Corporation MCP61 Ethernet (rev a2) 00:08.0 IDE interface: nVidia Corporation MCP61 SATA Controller (rev a2) 00:09.0 PCI bridge: nVidia Corporation MCP61 PCI Express bridge (rev a2) 00:0b.0 PCI bridge: nVidia Corporation MCP61 PCI Express bridge (rev a2) 00:0c.0 PCI bridge: nVidia Corporation MCP61 PCI Express bridge (rev a2) 00:0d.0 VGA compatible controller: nVidia Corporation C61 [GeForce 6150SE nForce 430] (rev a2) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 01:09.0 Ethernet controller: Intel Corporation 82557/8/9/0/1 Ethernet Pro 100 (rev 08) 02:00.0 VGA compatible controller: nVidia Corporation GT216 [GeForce GT 220] (rev a2) 02:00.1 Audio device: nVidia Corporation High Definition Audio Controller (rev a1) Output of lshw -class display: *-display description: VGA compatible controller product: GT216 [GeForce GT 220] vendor: nVidia Corporation physical id: 0 bus info: pci@0000:02:00.0 version: a2 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vga_controller bus_master cap_list rom configuration: driver=nvidia latency=0 resources: irq:18 memory:df000000-dfffffff memory:c0000000-cfffffff memory:da000000-dbffffff ioport:ef80(size=128) memory:def80000-deffffff *-display description: VGA compatible controller product: C61 [GeForce 6150SE nForce 430] vendor: nVidia Corporation physical id: d bus info: pci@0000:00:0d.0 version: a2 width: 64 bits clock: 66MHz capabilities: pm msi vga_controller bus_master cap_list rom configuration: driver=nvidia latency=0 resources: irq:22 memory:dd000000-ddffffff memory:b0000000-bfffffff memory:dc000000-dcffffff memory:deb40000-deb5ffff If what I'm looking for is not possible, please tell me, so I can disable the On board card and recover those 400MB of wasted RAM Thanks for your help!

    Read the article

  • Windows Azure Mobile Services Updates Keep Coming

    - by Clint Edmonson
    Some exciting new Windows Azure Mobile Services features were delivered to production this week. The highlights include: iPhone and iPad connectivity support via a new iOS SDK Integrated Authentication so developers can configure user authentication via Microsoft Account, Facebook, Twitter, and Google. New server-side Mobile Service script modules Access to Structured Storage, Windows Azure Blob, Table, Queues, and ServiceBus Email services through partnership with SendGrid SMS & voice services through partnership with Twilio Mobile Services hosting expanded to west coast US The iOS SDK I’m excited to share that we've announced the release of an under-development iOS client SDK for Windows Azure Mobile Services. The iOS SDK joins the Windows 8 SDK launched with Windows Azure Mobile Services as well as client SDKs released by Xamarin for MonoTouch and MonoDroid.  The native iOS SDK is for developers programming in Objective-C on the iPhone and iPad platforms. The SDK gives developers the same level of access to data storage using dynamic schematization that is available for Windows 8. Also, iOS applications can use the same authentication options available in Mobile Services. While full iOS support is still in development, the libraries are currently available on GitHub. There’s a great getting started tutorial to walk you through building a simple iOS “Todo List” app that stores data in Windows Azure.  These additional tutorials explore how to use the iOS client libraries to store data and authenticate users: Get Started with data in Mobile Services for iOS Get Started with authentication in Mobile Services for iOS What’s New in Authentication Available to both iOS and Windows 8 developers, Mobile Services has expanded its authentication options.  Developers can now use Microsoft, Facebook, Twitter, and Google authentication. Similar to using Microsoft accounts for authentication, developers must sign up and through Facebook, Twitter, or Google's developer portal in order to authenticate through them.  These tutorials walk through how to register your Mobile Service with an identity provider: How to register your app with Microsoft Account How to register your app with Facebook How to register your app with Twitter How to register your app with Google And these tutorials walk through authenticating against Mobile Services: Get started with authentication in Mobile Services for Windows Store (C#) Get started with authentication in Mobile Services for Windows Store (JavaScript) Get started with authentication in Mobile Services for iOS What’s New in Mobile Service Scripts Some great new functionality is now available in the Mobile Service script layer.  These server side scripts are triggered off of any CRUD operation on a Mobile Service's table and can already handle doing data and query validation, filtering, web requests and more.  Today, the Azure SDK module is now available to these scripts giving them access to blob storage, service bus, table storage.  Check out the new tutorials on the Windows Azure Node.js developer center to learn more about working with Blob, Tables, Queues and Service Bus using the azure module. In addition, SendGrid and Twilio are now available via modules that can be called from the scripts as well.  This gives developers the ability to send emails (SendGrid) or SMS text messages (Twilio) whenever a script is fired.  Windows Azure customers receive a special offer of 25,000 free emails per month from SendGrid and 1000 free text messages from Twilio. Expanded Data Center Availability In addition to Mobile Services being available in our US East data center, they can now be spun up in US West. The above features are all now live in production and are available to use immediately.  If you don’t already have a Windows Azure account, you can sign-up for a free trial and start using Mobile Services today. The Windows Azure Mobile Developer Center has been updated with new tutorials that cover these new features in detail. And don’t forget - Windows Azure Mobile Services are still free for your first ten applications running on shared compute instances. Stay tuned to my twitter feed for Windows Azure announcements, updates, and links: @clinted

    Read the article

  • Bluetooth not found on BCM43228

    - by TK Kocheran
    I've got a Broadcom BCM43228 mPCIe card which came with my motherboard (ASUS ROG Maximus V Extreme, can't seem to find a link to what the card is) which is working great for WiFi right now, but I can't detect the Bluetooth hardware onboard. In Windows, I have full Bluetooth 4.0 support. $ lspci 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:14.0 USB controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579V Gigabit Network Connection (rev 04) 00:1a.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) 00:1c.4 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 5 (rev c4) 00:1c.6 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 7 (rev c4) 00:1c.7 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 8 (rev c4) 00:1d.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Panther Point 6 port SATA Controller [AHCI mode] (rev 04) 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation Device 1189 (rev a1) 01:00.1 Audio device: NVIDIA Corporation Device 0e0a (rev a1) 0d:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 0e:00.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:01.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:04.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:05.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:06.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:07.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:08.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:09.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 10:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 12:00.0 SATA controller: ASMedia Technology Inc. ASM1062 Serial ATA Controller (rev 01) 15:00.0 Network controller: Broadcom Corporation BCM43228 802.11a/b/g/n 17:00.0 SATA controller: ASMedia Technology Inc. ASM1062 Serial ATA Controller (rev 01) The key line seems to be: 15:00.0 Network controller: Broadcom Corporation BCM43228 802.11a/b/g/n If I try to detect the Bluetooth card, I don't see anything: $ hcitool dev Devices: rfkill list all: Output lspci: Output lsusb: Output I finally found the card with usb-devices: T: Bus=01 Lev=02 Prnt=02 Port=00 Cnt=01 Dev#= 3 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=ff(vend.) Sub=01 Prot=01 MxPS=64 #Cfgs= 1 P: Vendor=0b05 ProdID=17b5 Rev=01.12 S: Manufacturer=Broadcom Corp S: Product=BCM20702A0 S: SerialNumber=############ C: #Ifs= 4 Cfg#= 1 Atr=e0 MxPwr=0mA I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=01 Prot=01 Driver=(none) I: If#= 1 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=01 Prot=01 Driver=(none) I: If#= 2 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none) I: If#= 3 Alt= 0 #EPs= 0 Cls=fe(app. ) Sub=01 Prot=01 Driver=(none) I've heard that this card needs to have firmware injected into it in order to function. If that's the case, how do I do it?

    Read the article

  • Next Generation Mobile Clients for Oracle Applications & the role of Oracle Fusion Middleware

    - by Manish Palaparthy
    Oracle Enterprise Applications have been available with modern web browser based interfaces for a while now. The web browsers available in smart phones no longer require special markup language such as WML since the processing power of these handsets is quite near to that of a typical personal computer. Modern Mobile devices such as the IPhone, Android Phones, BlackBerry, Windows 8 devices can now render XHTML & HTML quite well. This means you could potentially use your mobile browser to access your favorite enterprise application. While the Mobile browser would render the UI, you might find it difficult to use it due to the formatting & Presentation of the Native UI. Smart phones offer a lot more than just a powerful web browser, they offer capabilities such as Maps, GPS, Multi touch, pinch zoom, accelerometers, vivid colors, camera with video, support for 3G, 4G networks, cloud storage, NFC, streaming media, tethering, voice based features, multi tasking, messaging, social networking web browsers with support for HTML 5 and many more features.  While the full potential of Enterprise Mobile Apps is yet to be realized, Oracle has published a few of its applications that take advantage of the above capabilities and are available for the IPhone natively. Here are some of them Iphone Apps  Oracle Business Approvals for Managers: Offers a highly intuitive user interface built as a native mobile application to conveniently access pending actions related to expenses, purchase requisitions, HR vacancies and job offers. You can even view BI reports related to the worklist actions. Works with Oracle E-Business Suite Oracle Business Indicators : Real-time secure access to OBI reports. Oracle Business Approvals for Sales Managers: Enables sales executives to review key targeted tasks, access relevant business intelligence reports. Works with Siebel CRM, Siebel Quote & Order Capture. Oracle Mobile Sales Assistant: CRM application that provides real-time, secure access to the information your sales organization needs, complete frequent tasks, collaborate with colleagues and customers. Works with Oracle CRMOracle Mobile Sales Forecast: Designed specifically for the mobile business user to view key opportunities. Works with Oracle CRM on demand Oracle iReceipts : Part of Oracle PeopleSoft Expenses, which allows users to create and submit expense lines for cash transactions in real-time. Works with Oracle PeopleSoft expenses Now, we have seen some mobile Apps that Oracle has published, I am sure you are intrigued as to how develop your own clients for the use-cases that you deem most fit. For that Oracle has ADF Mobile ADF Mobile You could develop Mobile Applications with the SDK available with the smart phone platforms!, but you'd really have to be a mobile ninja developer to develop apps with the rich user experience like the ones above. The challenges really multiply when you have to support multiple mobile devices. ADF Mobile framework is really handy to meet this challenge ADF Mobile can in be used to Develop Apps for the Mobile browser : An application built with ADF Mobile framework installs on a smart device, renders user interface via HTML5, and has access to device services. This means the programming model is primarily web-based, which offers consistency with other enterprise applications as well as easier migration to new platforms. Develop Apps for the Mobile Client (Native Apps): These applications have access to device services, enabling a richer experience for users than a browser alone can offer. ADF mobile enables rapid and declarative development of rich, on-device mobile applications. Developers only need to write an application once and then they can deploy the same application across multiple leading smart phone platforms. Oracle SOA Suite Although the Mobile users are using the smart phone apps, and actual transactions are being executed in the underlying app, there is lot of technical wizardry that is going under the surface. All of this key technical components to make 1. WebService calls 2. Authentication 3. Intercepting Webservice calls and adding security credentials to the request 4. Invoking the services of the enterprise application 5. Integrating with the Enterprise Application via the Adapter is all being implemented at the SOA infrastructure layer.  As you can see from the above diagram. The key pre-requisites to mobile enable an Enterprise application are The core enterprise application Oracle SOA Suite ADF Mobile

    Read the article

  • Partner Webcast: Innovation in Products - October 1st, 2012 at 04:00 PM CET (03:00 PM GMT) Program

    - by Richard Lefebvre
    I am pleased to invite you to join the Innovations in Products – webcast. Innovations in Products will present Oracle Product's new functions and features including sales positioning. The key objectives of these webcasts are to inspire System Integrator's implementation personnel to conduct successful after sales in their Customer projects. Innovations in Products will be presented on the 1st Monday of each quarter after the billable day (4:00 to 5:00 PM CET). The webcast is intended for System Integrator's Implementation Certified Specialists but Innovations in Products is open for other system Integrator's personnel as well. At first, two Oracle representatives will discuss Oracle's contribution to partners. Then you will see product breakout session followed by Q&A with Oracle Experts. Each session will last for maximum 1 hour. A Q&A document covering all questions and answers will be made available after the webcast. What are the Benefits for partners? Find out how Innovations in Products helps you to improve your after sales Discover new functions and features so you can enrich your Customers's solution Learn more about Oracle products, especially sales positioning Hear crucial questions raised by colleague alike, learn from their interest Engage and present your questions to subject experts Be inspired of the richness of Oracle's product portfolio – for your and your customer's benefit. Note: Should you already be familiar with a specific Product, then choose another one. Doing so you would expand your knowledge of the overall product portfolio. Some presentations contain product demonstration, although these presentations are not intended to be extremely detailed technical presentations. Product breakout sessions available on October 1st:   Topics Speaker To Register Fusion HCM Social Capabilities, Enterprise social capabilities embedded in how you run your business Anca Dumitru, HCM Presales Consultant, EMEA Presales Center CLICK HERE Oracle Fusion Applications Security Concepts, Overview Alexandra Dan, Applications Technology Presales Consultant, EMEA Presales Centre CLICK HERE Fusion Financials Overview - Focus on Fusion Payables, Meeting the Payables' Challenges Elena Nita, Senior ERP Sales Consultant, EMEA Presales Center CLICK HERE Introduction to Oracle RightNow CX, Empowering companies to engage directly with their customers through great Social, Web, Chat and Contact Center experiences. Cais Champsi, Presales Consultant, EMEA Presales Centre CLICK HERE Oracle Endeca Information Discovery, Product Overview Emma Palii, BI Sales Consultant, EMEA Presales Center CLICK HERE To access previously presented 23 Applications Products presentations and 6 Public Sector Value Proposition presentations, please click here. You might want to bookmark the overall registration page Innovations in Products October 1st and the global event calendar page events.oracle.com. Delivery Format Innovations in Products – program is a series of FREE prerecorded Oracle product presentations followed by Q&A. It will be delivered over the Web. Participants have the opportunity to submit questions during the web cast via chat and subject matter experts will provide verbal answers live. Innovations in Products consists of several parallel prerecorded product breakout sessions, each lasting for max. 1 hour. At first, two Oracle representatives will discuss Oracle's contribution to Partners. Then you'll see the product breakout sessions followed by Q&A with Oracle Experts. A Q&A document covering all questions and answers will be made available after the webcast. You can also see Innovations in Products afterwards as its content will be available online for the next 6-12 months. The next Innovations in Products web casts will be presented as follows: October 1st 2012 January 14th 2013 April 8th 2013. Note: Depending on local network bandwidth please allow some seconds time the presentations to download. You might want to refresh your screen by pressing F5. Duration: Maximum 1 hour For further information please contact me Markku Rouhiainen. Best regards Markku Rouhiainen Director, Applications Partner Enablement EMEA

    Read the article

  • SPARC T5-4 LDoms for RAC and WebLogic Clusters

    - by Jeff Taylor-Oracle
    I wanted to use two Oracle SPARC T5-4 servers to simultaneously host both Oracle RAC and a WebLogic Server Cluster. I chose to use Oracle VM Server for SPARC to create a cluster like this: There are plenty of trade offs and decisions that need to be made, for example: Rather than configuring the system by hand, you might want to use an Oracle SuperCluster T5-8 My configuration is similar to jsavit's: Availability Best Practices - Example configuring a T5-8 but I chose to ignore some of the advice. Maybe I should have included an  alternate service domain, but I decided that I already had enough redundancy Both Oracle SPARC T5-4 servers were to be configured like this: Cntl 0.25  4  64GB                     App LDom                    2.75 CPU's                                        44 cores                                          704 GB              DB LDom      One CPU         16 cores         256 GB   The systems started with everything in the primary domain: # ldm list NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  NORM  UPTIME primary          active     -n-c--  UART    512   1023G    0.0%  0.0%  11m # ldm list-spconfig factory-default [current] primary # ldm list -o core,memory,physio NAME              primary           CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23) -- SNIP     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                 0x30000000       0x30000000       255G     0x80000000000    0x80000000000    256G     0x100000000000   0x100000000000   256G     0x180000000000   0x180000000000   256G # Give this memory block to the DB LDom IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0                pci@340                          pci_1                pci@380                          pci_2                pci@3c0                          pci_3                pci@400                          pci_4                pci@440                          pci_5                pci@480                          pci_6                pci@4c0                          pci_7                pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0        pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8     pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2    Added an additional service processor configuration: # ldm add-spconfig split # ldm list-spconfig factory-default primary split [current] And removed many of the resources from the primary domain: # ldm start-reconf primary # ldm set-core 4 primary # ldm set-memory 32G primary # ldm rm-io pci@340 primary # ldm rm-io pci@380 primary # ldm rm-io pci@3c0 primary # ldm rm-io pci@400 primary # ldm rm-io pci@440 primary # ldm rm-io pci@480 primary # ldm rm-io pci@4c0 primary # init 6 Needed to add resources to the guest domains: # ldm add-domain db # ldm set-core cid=`seq -s"," 48 63` db # ldm add-memory mblock=0x180000000000:256G db # ldm add-io pci@480 db # ldm add-io pci@4c0 db # ldm add-domain app # ldm set-core 44 app # ldm set-memory 704G  app # ldm add-io pci@340 app # ldm add-io pci@380 app # ldm add-io pci@3c0 app # ldm add-io pci@400 app # ldm add-io pci@440 app Needed to set up services: # ldm add-vds primary-vds0 primary # ldm add-vcc port-range=5000-5100 primary-vcc0 primary Needed to add a virtual network port for the WebLogic application domain: # ipadm NAME              CLASS/TYPE STATE        UNDER      ADDR lo0               loopback   ok           --         --    lo0/v4         static     ok           --         ...    lo0/v6         static     ok           --         ... net0              ip         ok           --         ...    net0/v4        static     ok           --         xxx.xxx.xxx.xxx/24    net0/v6        addrconf   ok           --         ....    net0/v6        addrconf   ok           --         ... net8              ip         ok           --         --    net8/v4        static     ok           --         ... # dladm show-phys LINK              MEDIA                STATE      SPEED  DUPLEX    DEVICE net1              Ethernet             unknown    0      unknown   ixgbe1 net0              Ethernet             up         1000   full      ixgbe0 net8              Ethernet             up         10     full      usbecm2 # ldm add-vsw net-dev=net0 primary-vsw0 primary # ldm add-vnet vnet1 primary-vsw0 app Needed to add a virtual disk to the WebLogic application domain: # format Searching for disks...done AVAILABLE DISK SELECTIONS:        0. c0t5000CCA02505F874d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02505f874           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD0/disk        1. c0t5000CCA02506C468d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c468           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD1/disk        2. c0t5000CCA025067E5Cd0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca025067e5c           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD2/disk        3. c0t5000CCA02506C258d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c258           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD3/disk Specify disk (enter its number): ^C # ldm add-vdsdev /dev/dsk/c0t5000CCA02506C468d0s2 HDD1@primary-vds0 # ldm add-vdisk HDD1 HDD1@primary-vds0 app Add some additional spice to the pot: # ldm set-variable auto-boot\\?=false db # ldm set-variable auto-boot\\?=false app # ldm set-var boot-device=HDD1 app Bind the logical domains: # ldm bind db # ldm bind app At the end of the process, the system is set up like this: # ldm list -o core,memory,physio NAME             primary          CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23)     3      (24, 25, 26, 27, 28, 29, 30, 31) MEMORY     RA               PA               SIZE                0x30000000       0x30000000       32G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0               pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0   ------------------------------------------------------------------------------ NAME             app              CORE     CID    CPUSET     4      (32, 33, 34, 35, 36, 37, 38, 39)     5      (40, 41, 42, 43, 44, 45, 46, 47)     6      (48, 49, 50, 51, 52, 53, 54, 55)     7      (56, 57, 58, 59, 60, 61, 62, 63)     8      (64, 65, 66, 67, 68, 69, 70, 71)     9      (72, 73, 74, 75, 76, 77, 78, 79)     10     (80, 81, 82, 83, 84, 85, 86, 87)     11     (88, 89, 90, 91, 92, 93, 94, 95)     12     (96, 97, 98, 99, 100, 101, 102, 103)     13     (104, 105, 106, 107, 108, 109, 110, 111)     14     (112, 113, 114, 115, 116, 117, 118, 119)     15     (120, 121, 122, 123, 124, 125, 126, 127)     16     (128, 129, 130, 131, 132, 133, 134, 135)     17     (136, 137, 138, 139, 140, 141, 142, 143)     18     (144, 145, 146, 147, 148, 149, 150, 151)     19     (152, 153, 154, 155, 156, 157, 158, 159)     20     (160, 161, 162, 163, 164, 165, 166, 167)     21     (168, 169, 170, 171, 172, 173, 174, 175)     22     (176, 177, 178, 179, 180, 181, 182, 183)     23     (184, 185, 186, 187, 188, 189, 190, 191)     24     (192, 193, 194, 195, 196, 197, 198, 199)     25     (200, 201, 202, 203, 204, 205, 206, 207)     26     (208, 209, 210, 211, 212, 213, 214, 215)     27     (216, 217, 218, 219, 220, 221, 222, 223)     28     (224, 225, 226, 227, 228, 229, 230, 231)     29     (232, 233, 234, 235, 236, 237, 238, 239)     30     (240, 241, 242, 243, 244, 245, 246, 247)     31     (248, 249, 250, 251, 252, 253, 254, 255)     32     (256, 257, 258, 259, 260, 261, 262, 263)     33     (264, 265, 266, 267, 268, 269, 270, 271)     34     (272, 273, 274, 275, 276, 277, 278, 279)     35     (280, 281, 282, 283, 284, 285, 286, 287)     36     (288, 289, 290, 291, 292, 293, 294, 295)     37     (296, 297, 298, 299, 300, 301, 302, 303)     38     (304, 305, 306, 307, 308, 309, 310, 311)     39     (312, 313, 314, 315, 316, 317, 318, 319)     40     (320, 321, 322, 323, 324, 325, 326, 327)     41     (328, 329, 330, 331, 332, 333, 334, 335)     42     (336, 337, 338, 339, 340, 341, 342, 343)     43     (344, 345, 346, 347, 348, 349, 350, 351)     44     (352, 353, 354, 355, 356, 357, 358, 359)     45     (360, 361, 362, 363, 364, 365, 366, 367)     46     (368, 369, 370, 371, 372, 373, 374, 375)     47     (376, 377, 378, 379, 380, 381, 382, 383) MEMORY     RA               PA               SIZE                0x30000000       0x830000000      192G     0x4000000000     0x80000000000    256G     0x8080000000     0x100000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@340                          pci_1               pci@380                          pci_2               pci@3c0                          pci_3               pci@400                          pci_4               pci@440                          pci_5               pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8 ------------------------------------------------------------------------------ NAME             db               CORE     CID    CPUSET     48     (384, 385, 386, 387, 388, 389, 390, 391)     49     (392, 393, 394, 395, 396, 397, 398, 399)     50     (400, 401, 402, 403, 404, 405, 406, 407)     51     (408, 409, 410, 411, 412, 413, 414, 415)     52     (416, 417, 418, 419, 420, 421, 422, 423)     53     (424, 425, 426, 427, 428, 429, 430, 431)     54     (432, 433, 434, 435, 436, 437, 438, 439)     55     (440, 441, 442, 443, 444, 445, 446, 447)     56     (448, 449, 450, 451, 452, 453, 454, 455)     57     (456, 457, 458, 459, 460, 461, 462, 463)     58     (464, 465, 466, 467, 468, 469, 470, 471)     59     (472, 473, 474, 475, 476, 477, 478, 479)     60     (480, 481, 482, 483, 484, 485, 486, 487)     61     (488, 489, 490, 491, 492, 493, 494, 495)     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                0x80000000       0x180000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@480                          pci_6               pci@4c0                          pci_7               pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2   Start the domains: # ldm start app LDom app started # ldm start db LDom db started Make sure to start the vntsd service that was created, above. # svcs -a | grep ldo disabled        8:38:38 svc:/ldoms/vntsd:default online          8:38:58 svc:/ldoms/agents:default online          8:39:25 svc:/ldoms/ldmd:default # svcadm enable vntsd Now use the MAC address to configure the Solaris 11 Automated Installation. Database Logical Domain # telnet localhost 5000 {0} ok devalias screen                   /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@7/display@0 disk7                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p3 disk6                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p2 disk5                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p1 disk4                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p0 scsi1                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0 net3                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0,1 net2                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net2 Boot device: /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0  File and args: 1000 Mbps full duplex Link up Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx WLS Logical Domain # telnet localhost 5001 {0} ok devalias hdd1                     /virtual-devices@100/channel-devices@200/disk@0 vnet1                    /virtual-devices@100/channel-devices@200/network@0 net                      /virtual-devices@100/channel-devices@200/network@0 disk                     /virtual-devices@100/channel-devices@200/disk@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net Boot device: /virtual-devices@100/channel-devices@200/network@0  File and args: Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx Repeat the process for the second SPARC T5-4, install Solaris, RAC and WebLogic Cluster, and you are ready to go. Maybe buying a SuperCluster would have been easier.

    Read the article

  • RPi and Java Embedded GPIO: Big Data and Java Technology

    - by hinkmond
    Java Embedded and Big Data go hand-in-hand, especially as demonstrated by prototyping on a Raspberry Pi to show how well the Java Embedded platform can perform on a small embedded device which then becomes the proof-of-concept for industrial controllers, medical equipment, networking gear or any type of sensor-connected device generating large amounts of data. The key is a fast and reliable way to access that data using Java technology. In the previous blog posts you've seen the integration of a static electricity sensor and the Raspberry Pi through the GPIO port, then accessing that data through Java Embedded code. It's important to point out how this works and why it works well with Java code. First, the version of Linux (Debian Wheezy/Raspian) that is found on the RPi has a very convenient way to access the GPIO ports through the use of Linux OS managed file handles. This is key in avoiding terrible and complex coding using register manipulation in C code, or having to program in a less elegant and clumsy procedural scripting language such as python. Instead, using Java Embedded, allows a fast way to access those GPIO ports through those same Linux file handles. Java already has a very easy to program way to access file handles with a high degree of performance that matches direct access of those file handles with the Linux OS. Using the Java API java.io.FileWriter lets us open the same file handles that the Linux OS has for accessing the GPIO ports. Then, by first resetting the ports using the unexport and export file handles, we can initialize them for easy use in a Java app. // Open file handles to GPIO port unexport and export controls FileWriter unexportFile = new FileWriter("/sys/class/gpio/unexport"); FileWriter exportFile = new FileWriter("/sys/class/gpio/export"); ... // Reset the port unexportFile.write(gpioChannel); unexportFile.flush(); // Set the port for use exportFile.write(gpioChannel); exportFile.flush(); Then, another set of file handles can be used by the Java app to control the direction of the GPIO port by writing either "in" or "out" to the direction file handle. // Open file handle to input/output direction control of port FileWriter directionFile = new FileWriter("/sys/class/gpio/gpio" + gpioChannel + "/direction"); // Set port for input directionFile.write("in"); // Or, use "out" for output directionFile.flush(); And, finally, a RandomAccessFile handle can be used with a high degree of performance on par with native C code (only milliseconds to read in data and write out data) with low overhead (unlike python) to manipulate the data going in and out on the GPIO port, while the object-oriented nature of Java programming allows for an easy way to construct complex analytic software around that data access functionality to the external world. RandomAccessFile[] raf = new RandomAccessFile[GpioChannels.length]; ... // Reset file seek pointer to read latest value of GPIO port raf[channum].seek(0); raf[channum].read(inBytes); inLine = new String(inBytes); It's Big Data from sensors and industrial/medical/networking equipment meeting complex analytical software on a small constraint device (like a Linux/ARM RPi) where Java Embedded allows you to shine as an Embedded Device Software Designer. Hinkmond

    Read the article

  • TechEd North America 2012 – Day 1 #msTechEd

    - by Marco Russo (SQLBI)
    Yesterday I and Alberto delivered the PreCon day about BISM Tabular in Analysis Services 2012. We received very good feedback and now I am looking forward to meet people that read our blogs and our books! Ping me on Twitter at @marcorus if you want to contact me during the conference. This is my schedule for the next few days: ·         Monday, June 11, 2012 o   10:30am-12:30pm I will be in the Technical Learning Center area, at the Breaktrough Insights (station #8) in the Database & Business Intelligence area (dedicated to SQL Server 2012) o   I will try to watch some sessions in the afternoon o   6:30pm-7:00pm I will be at the O’Reilly booth meeting book readers and doing some book signing ·         Tuesday, June 12, 2012 o   12:30pm-3:30pm I will be in the Technical Learning Center area, at the Breaktrough Insights (station #8) in the Database & Business Intelligence area (dedicated to SQL Server 2012) o   5:00pm-6:15pm I will attend the Alberto’s session DBI413 Many-to-Many Relationships in BISM Tabular (room S330E) o   6:15pm-9:00pm Community Night & Ask the Experts, we’ll discuss about Analysis Services, Tabular and Multidimensional! ·         Wednesday, June 13, 2012 o   11:15am-11:30am Don’t miss this special demo session at the Private Cloud, Public Cloud and Data Platform Theater in the Technical Learning Center area (next to the SQL Server 2012 zone). I and Alberto will present Querying multi-billion rows with many to many relationships in SSAS Tabular (xVelocity) and you’re invited to guess the response time of DAX queries on a 4 billion rows table with many-to-many relationships before we run them! We’ll give away some 8GB USB key if you guess the right answer! o   12:30pm-1:00pm I and Alberto will have a book signing session at the TechEd Bookstore o   3:00pm-5:00pm I will be in the Technical Learning Center area, at the Breaktrough Insights (station #8) in the Database & Business Intelligence area (dedicated to SQL Server 2012) ·         Thursday, June 14, 2012 o   2:45pm-4:00pm I will deliver my DBI319 BISM: Multidimensional vs. Tabular breakthrough session in room S320A. I expect many questions here! And if you want to learn more about Analysis Services Tabular, we announced two more online sessions of our SSAS Tabular Workshop: ·         July 2-3, 2012 - SSAS Workshop Online - America's time zone ·         September 3-4, 2012 - SSAS Workshop Online - America's time zone Register now if you are interested, the early bird for the July session expires on June 19, 2012! I will also deliver a SSAS Workshop in Oslo (Norway) on August 27-28, 2012.  

    Read the article

< Previous Page | 156 157 158 159 160 161 162 163 164 165 166 167  | Next Page >