  • Windows 7 boot problem (with colorful blinking smilies)

    - by Ishmael Smyrnow
    I put my computer (Windows 7) to sleep, and a couple hours later, tried to wake it back up, but the monitor wouldn't come back on. I did a hard reset (held power button), but I still couldn't get the monitor to show anything. I plugged it into my laptop, and the monitor works fine. I then swapped out the video card with an older one I have. The monitor came on and started showing the boot process. However, shortly after the Windows 7 animated logo came up, the screen went blank, it made this weird beeping noise, and I seen the strangest thing ever. Small, colorful blocks started to fill my screen, and flash, as if something was loading. Inside of those blocks, were smilies (like the ASCII character kind). This continued for about a minute, then the computer rebooted. It scared the sh!t out of me. I've never had a virus before, and I'm savvy enough to keep myself from one, but I'm wondering if that's what it was. I've been using computers for ages, and never seen anything quite like this. Has anyone ever seen something like this? I'm doing hardware diagnostics before trying to boot into Windows again. Hopefully I can figure this out, but I thought I would consult the SU community while I wait on these results. -- UPDATE -- I did a Memory Diagnostic, which turned up nothing. I also booted into Safe Mode no problem, and scheduled a disk check on both of my drives (I dual boot XP & 7). I was feeling good, and tried putting my regular video card back in, and the monitor won't display anything with it. Also, even though the monitor displays nothing, the system sounds like it's booting up. However, I hear a clicking in one of my hard drives that isn't there with the older video card. Could this be a problem with my hard drive, video card, or PSU? PSU makes sense, except for the fact I've been using the same setup for over a year, and the video card doesn't require it's own power plug thing.

    Read the article

  • Asynchronous readback from opengl front buffer using multiple PBO's

    - by KillianDS
    I am developing an application that needs to read back the whole frame from the front buffer of an openGL application. I can hijack the application's opengl library and insert my code on swapbuffers. At the moment I am successfully using a simple but excruciating slow glReadPixels command without PBO's. Now I read about using multiple PBO's to speed things up. While I think I've found enough resources to actually program that (isn't that hard), I have some operational questions left. I would do something like this: create a series (e.g. 3) of PBO's use glReadPixels in my swapBuffers override to read data from front buffer to a PBO (should be fast and non-blocking, right?) Create a seperate thread to call glMapBufferARB, once per PBO after a glReadPixels, because this will block until the pixels are in client memory. Process the data from step 3. Now my main concern is of course in steps 2 and 3. I read about glReadPixels used on PBO's being non-blocking, will this be an issue if I issue new opengl commands after that very fast? Will those opengl commands block? Or will they continue (my guess), and if so, I guess only swapbuffers can be a problem, will this one stall or will glReadPixels from front buffer be many times faster than swapping (about each 15-30ms) or, worst case scenario, will swapbuffers be executed while glReadPixels is still reading data to the PBO? My current guess is this logic will do something like this: copy FRONT_BUFFER - generic place in VRAM, copy VRAM-RAM. But I have no idea which of those 2 is the real bottleneck and more, what the influence on the normal opengl command stream is. Then in step 3. Is it wise to do this asynchronously in a thread separated from normal opengl logic? At the moment I think not, It seems you have to restore buffer operations to normal after doing this and I can't install synchronization objects in the original code to temporarily block those. So I think my best option is to define a certain swapbuffer delay before reading them out, so e.g. calling glReadPixels on PBO i%3 and glMapBufferARB on PBO (i+2)%3 in the same thread, resulting in a delay of 2 frames. Also, when I call glMapBufferARB to use data in client memory, will this be the bottleneck or will glReadPixels (asynchronously) be the bottleneck? And finally, if you have some better ideas to speed up frame readback from GPU in opengl, please tell me, because this is a painful bottleneck in my current system. I hope my question is clear enough, I know the answer will probably also be somewhere on the internet but I mostly came up with results that used PBO's to keep buffers in video memory and do processing there. I really need to read back the front buffer to RAM and I do not find any clear explanations about performance in that case (which I need, I cannot rely on "it's faster", I need to explain why it's faster). Thank you

    Read the article

  • How to diagnose repeated "Starting up database '<dbname>'"

    - by Richard Slater
    I have a SQL 2008 server which is predominantly used as a development server, in the last two weeks it has been having occasional "fits", I have isolated the cause of these fits as CHECKDB being run almost continuiously, the following log information is logged to the Windows Event Log (Source: MSSQLSERVER, Category: Server): Event: 1073758961, Message: Starting up database 'DBName1'. Event: 1073758961, Message: Starting up database 'DBName2'. Event: 1073759397, Message: CHECKDB for database 'DBName1' finished without errors on 2010-07-19 20:29:26.993 (local time). This is an informational message only; no user action is required. Event: 1073759397, Message: CHECKDB for database 'DBName1' finished without errors on 2010-07-19 20:29:26.993 (local time). This is an informational message only; no user action is required. This is repeated every 1-2 seconds untill SQL Server is restarted or the offending databases are detatched. I initially thought that it was a problem with the databases so I took a backup and restored them to a SQL Express instance, all of the data is in tact, and CHECKDB runs without problem. The two databases that were causing a problem last week were not being used; so I took full backups of them and detached the databases, this resolved the problem. However at 0100 GMT this morning to other totally unrelated databases started showing the same problems. There is nothing in the event log to suggest that something happened to the server such as a restart, there are no messages about processes crashing or issues being detected with the storage controller. Speaking to the owner of the company this computer has suffered from "gremlins" in the past, however advice was taken and the motherboard was replaced and the computer rebuilt, memory and processor are the same. Stats: O/S: Windows 2008 Standard Build 6002 CPU: 2x Pentium Dual-Core E5200 @ 2.5GHz RAM: 2GB SQL: 2008 Standard 10.0.2531 Edit: someone posted then deleted a comment about AutoClose, it was turned on on the databases affected. It seems that best practice is to disable it so I have done that with the folllowing. EXECUTE sp_MSforeachdb 'IF (''?'' NOT IN (''master'', ''tempdb'', ''msdb'', ''model'')) EXECUTE (''ALTER DATABASE [?] SET AUTO_CLOSE OFF WITH NO_WAIT'')' I won't know if the problem recurs for some time so I am still open to further answers.

    Read the article

  • Windows 7 x64 installation freezes on new PC build

    - by jhsowter
    Symptoms While attempting to install Windows 7 (64 bit) on my new PC build, it freezes usually at the point where it is expanding the windows image, but has frozen as early as accepting the licence agreement, and as late as just after the first restart. My specs are at the bottom of the post. So far I have tried the following to identify the problem, in rough chronological order: Tried different hard drives with different sata cables. Same symptoms. I later used a different computer to install windows on the same hard drive with no problems. Tried the RAM in different slots, and tried one RAM stick instead of two. Same symptoms. Updated the BIOS to 1.60. Same symptoms. Ran Memtest86+ with RAM in dual channel. It passed about 6 times when I left it running overnight. Used USB to install windows instead of an optical drive. Same symptoms. Change SATA configuration from AHCI to IDE. Same symptoms. Tried various different SATA ports. Same symptoms. Updated BIOS to 1.70. Same symptoms. I saw the RAM did not list my motherboard as being supported even though the motherboard did list the RAM as being supported. So I tried some Kingston DDR3 1333MHz RAM instead. Same symptoms. Other (possibly) pertinent information My CPU idles at about 30 °C. I can't tell what it gets to when it's working. When I installed the CPU, the lever which locks the CPU in place took quite a bit of force to pull down. Now I didn't just yank it down without rechecking the CPU was seated properly about 5 times, but it does seems unusual, and I wonder if the CPU was seated badly if I would see these symptoms? I am out of ideas and don't know how to diagnose any further. I suppose either the motherboard or CPU must be the problem. I am on the verge of taking it to a specialist. The Question How should I proceed from here? Is there anything I can rule out as being the source of the symptoms I am seeing? My Specs CPU: Intel i5 3570k RAM: G.Skill RipjawsX 8GB kit HDD: single 3.5" 500GB SATA or 160GB 2.5" SATA (at different times and sometime together. But no RAID or anything). MB: ASRock Extreme4 Z77 PSU: Silverstone Strider Plus 600W ST60F-P

    Read the article

  • Splitting an internet connection between multiple separate subnetworks

    - by pythonian4000
    Problem I have an internet connection that I want to split between four separate networks. My requirements are: I need to be able to monitor the amount of bandwidth and data being used by each network, and notify or control as necessary. The four networks should only be able to connect to the internet, not each other. My parents need to be able to operate it, so it needs a simple, preferably Windows-based GUI. Progress so far Server I have a mini-ITX server with six Gigabit ethernet ports - one for the ethernet internet connection, one for each of the four networks, and one for remote access to the server for administration. Bandwidth control I spent a long time researching solutions here. The majority of the control systems/software I found could control bandwidth usage via QOS, but could not monitor or control the amount of data being used. Eventually I found the SoftPerfect Bandwidth Manager, which has everything I need in terms of monitoring and control - per-interface quota management, usage statistics, a web interface for checking usage, and email notifications when quotas are exceeded. It is also Windows-based and has a simple GUI. Internet sharing This is where I am having issues. I am currently using Windows XP Pro SP2 for the server (yes, I know this is far from ideal, but it's the only spare Windows OS I currently have). I can't use the built-in Internet Connection Sharing for several reasons: The upstream internet router has an IP of 192.168.0.1 which ICS clashes with, and I cannot change the router settings. ICS can only share an internet connection with a single interface, but I have four. I have tried bridging the four network cards, but then the Bandwidth Manager cannot see the four individual interfaces - it only sees the bridge. I have tried setting up Dual DHCP DNS server (and am having issues getting DHCP offers to be received by clients), but that would still require gateway software of some sort, which I have been unable to find. My current attempt is to use OpenVPN, with a server for the internet NIC and a separate client for each of the four networks. My thought is that I could bridge the OpenVPN TAP devices to each NIC, meaning that the Bandwidth Manager would control traffic from the bridge instead of the interface. I have not made much progress here though - I've never used OpenVPN before. Questions Is there a Windows software package that does everything I need? (Unlikely, I know) Is there a Windows software package that will share internet between multiple NICs without bridging? Are either of my about attempts feasible? Would it help to have a newer/server version of Windows? Is there a non-Windows alternative that is easy to use?

    Read the article

  • Linux Mint 14 severe overheating

    - by agvares
    I've tried switching to Mint (it was Mint 12) about 6 months ago, but failed to do it due to enormous overheating which made it virtually impossible to run any applications more complex than Gedit. Time had passed, and now I'm back again with Mint 14, but feeling way more determined. What I face are the following issues: 1) Great overheating (and by great I mean that just by doing nothing my CPU temp is floating around 70-75 C, which I find a lot) 2) Running multiple applications (let's say Chrome, Skype and Pidgin) results in critical overheating and immediate shutdown of the system 3) Due to the stuff listed above, my battery drains in about 10-15 minutes, pretty much turning my laptop into a crippled desktop machine I've got a HP-dv6 laptop (i7, 6gb RAM, dual graphics) Here's the output of lspci: 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:16.0 Communication controller: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 (rev 04) 00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) 00:1c.1 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 2 (rev b5) 00:1c.2 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 3 (rev b5) 00:1c.3 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 4 (rev b5) 00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation HM65 Express Chipset Family LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 05) 01:00.0 VGA compatible controller: Advanced Micro Devices [AMD] nee ATI Whistler XT [AMD Radeon HD 6700M Series] 07:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0d:00.0 Network controller: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller (rev 01) 13:00.0 Unassigned class [ff00]: Realtek Semiconductor Co., Ltd. RTS5209 PCI Express Card Reader (rev 01) 19:00.0 USB controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) what i've tried to do already: 1) I've edited my grub file to add some "splash" arguments there 2) Installed jupiter and powertop 3) Tried to upgrade to newer kernels (up to 3.8), btw running anything newer than 3.5 results in both resolution and wi-fi detection fail 4) Read lots of forum threads devoted to the topic So, my question is simple: What else might I do to become finally able to use Mint as my default OS without the risk of being burned alive by the CPU heat?

    Read the article

  • Why do I have multiple drives in my backup system image?

    - by bebop
    I have a drive which has 2 partitions. One is where the OS is installed, the other is a data (but not libraries) drive. When I try and create a backup using the built in tool, it wants to include both partitions in the system image. Why does it do this? If I move the os to a separate drive will I be able to back up just this data? Edit: To be more clear. I have 4 disks in the machine. 1 disc has 2 partitions. These are c: and e:, the other disks are d: f: and h:. The OS is installed on c: and libraries are stored on h:. The libraries are already backed up using crashplan, but I want to create a system image so I can easily restore the machine, if it either dies or if I get a SSD drive. When I choose backup (either through the wizard or if I open it through control panel) and check (or click) create a system image it automatically adds both c: and e: to the list of drives that will be backed up, and I cannot change this, the checkboxes to unselect are greyed out. I would like to know why it automatically adds e: to the list (but not h:, where the libraries are) and if I can change some setting so whatever files it has on e: that it thinks need to be backed up as part of the system image are moved to c:. How can I determine what they are? Is it because c: and e: are partitions of the same disk? If I move c: tro a different disk will that mean I only have to back up c:? Thanks Edit 2: I have viewed all files including hidden and system ones on both drives and it seems that I have a suspicous hidden e:\boot\ folder. I think that I might have installed the OS as a VHD at first then installed a seperate version straight on the disk, having dual boot for a while, then used EasyBCD to remove the VHD boot and file. Might this be what is causing my issue? How might I go about removing this? is it safe to just delete the boot folder?

    Read the article

  • Quantifying the effects of partition mis-alignment

    - by Matt
    I'm experiencing some significant performance issues on an NFS server. I've been reading up a bit on partition alignment, and I think I have my partitions mis-aligned. I can't find anything that tells me how to actually quantify the effects of mis-aligned partitions. Some of the general information I found suggests the performance penalty can be quite high (upwards of 60%) and others say it's negligible. What I want to do is determine if partition alignment is a factor in this server's performance problems or not; and if so, to what degree? So I'll put my info out here, and hopefully the community can confirm if my partitions are indeed mis-aligned, and if so, help me put a number to what the performance cost is. Server is a Dell R510 with dual E5620 CPUs and 8 GB RAM. There are eight 15k 2.5” 600 GB drives (Seagate ST3600057SS) configured in hardware RAID-6 with a single hot spare. RAID controller is a Dell PERC H700 w/512MB cache (Linux sees this as a LSI MegaSAS 9260). OS is CentOS 5.6, home directory partition is ext3, with options “rw,data=journal,usrquota”. I have the HW RAID configured to present two virtual disks to the OS: /dev/sda for the OS (boot, root and swap partitions), and /dev/sdb for a big NFS share: [root@lnxutil1 ~]# parted -s /dev/sda unit s print Model: DELL PERC H700 (scsi) Disk /dev/sda: 134217599s Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 63s 465884s 465822s primary ext2 boot 2 465885s 134207009s 133741125s primary lvm [root@lnxutil1 ~]# parted -s /dev/sdb unit s print Model: DELL PERC H700 (scsi) Disk /dev/sdb: 5720768639s Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 34s 5720768606s 5720768573s lvm Edit 1 Using the cfq IO scheduler (default for CentOS 5.6): # cat /sys/block/sd{a,b}/queue/scheduler noop anticipatory deadline [cfq] noop anticipatory deadline [cfq] Chunk size is the same as strip size, right? If so, then 64kB: # /opt/MegaCli -LDInfo -Lall -aALL -NoLog Adapter #0 Number of Virtual Disks: 2 Virtual Disk: 0 (target id: 0) Name:os RAID Level: Primary-6, Secondary-0, RAID Level Qualifier-3 Size:65535MB State: Optimal Stripe Size: 64kB Number Of Drives:7 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Number of Spans: 1 Span: 0 - Number of PDs: 7 ... physical disk info removed for brevity ... Virtual Disk: 1 (target id: 1) Name:share RAID Level: Primary-6, Secondary-0, RAID Level Qualifier-3 Size:2793344MB State: Optimal Stripe Size: 64kB Number Of Drives:7 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Number of Spans: 1 Span: 0 - Number of PDs: 7 If it's not obvious, virtual disk 0 corresponds to /dev/sda, for the OS; virtual disk 1 is /dev/sdb (the exported home directory tree).

    Read the article

  • Intermittent internet access on a flat network - Router is connected

    - by Naveed
    I’m looking for some help with network settings. I’ve just started a new job (non-IT!) and we have problems with our office network. I’m the most IT literate in the organisation (15 permanent employees) and so have been dealing with IT issues. Our main bit of software is web-based so we need constant web access but it sometimes goes down for between 20 minutes and 3 hours despite everything seemingly working fine. It’s a flat network with wireless APs, BT Business Broadband 8Mbit connection and that’s about it. We have no servers and no standard settings and staff are encouraged to bring in their own laptops and connect! The network basically exists to provide internet access and that’s it. We also have students accessing the wireless (and I know there’s a whole list of access and content issues etc but right now we just need internet access stabilised). This is what we have: Building 1 Cisco SLM-224P 24-port PoE 10/100 switch with 2 gigabit ports 3 x ZyXEL NWA-3160 wireless APs Samsung OfficeServ 7100 phone server which borrows the building’s wiring Building 2 Netgear GS605-UK 5-port 10/100/1000 switch 1 x ZyXEL NWA-3160 wireless AP 1 x BT Business Hub – 2wire BT2700hgv – is the DHCP server We have 2 link cables between the buildings. One connects the two switches on a gigabit port. The second (oddly) connects the switch in building 2 to the OfficeServ server in building 1. When the internet goes down I can still access the router through a wireless connection. I can also ping websites and get a response. Firefox just says “Cannot connect” etc. The system then heals itself when it feels like it. (Sorry if this is asking too much but) These are my immediate questions… Why would browser-based internet go down? I don’t know enough about protocols etc but I can try to standardise settings. The WAPs have a DNS server setting and I don’t know whether it should be “None” or “From DHCP”. What should be the DHCP server? The router or the Cisco switch? Or something else?! Would there be any problem in connecting the second link from switch to switch? Is that good practice? Is it worth swapping the Netgear GS605 with either a Cisco SG200-08 or Netgear GS108T-200? Is it worth upgrading the router to, for instance, a Cisco RV042G Dual Gigabit router which would also act as a switch? Or is it better to have a separate router and switch in Building 2?

    Read the article

  • Lenovo Ideapad Y480 can't reinstall windows?

    - by elegantonyx
    Alright, so here's the deal... For a while, I wanted to mess with Linux. I don't know why, but I wanted to. So, what I did was use WUBI and install Ubuntu. Because of some unknown reason (Intel Rapid Start? Half the drivers being on a Lenovo-installed SSD [separate from the main hard drive]?) it wouldn't dual boot. So, I decided to use Linux Mint instead, and install it in a partition. Since Windows 7 Home Premium won't make partitions any more if you have a certain number already, I just shrank my system drive and left empty space for the installer to claim. When I installed Mint, it worked, but left my Windows 7 installation unable to boot and eventually it corrupted. I tried to use a system repair disc I burned earlier but it didn't find the Windows installation, so I assume the partition corrupted. I used this link:http://www.pcworld.com/article/248995/how_to_install_windows_7_without_the_disc.html to try and reinstall Windows. What happened was that originally it said that the partition I was trying to reinstall from had been locked down by the OEM (Lenovo). So, I went into GParted, wiped EVERYTHING, and selected 'Construct new Boot record' or whatever that function is, and now the error is: "Setup was unable to create a new system partition or locate an existing system partition. See the setup log files for more information." Does anyone know how to see the log files? Can anyone help? This system is a month old but the warranty only covers hardware failures, and I would need to pay around USD$60 for them to fix it. Please help. Any ideas? this is my main machine... Extra information: I have at my disposal: System Repair Disc (Burned myself) Windows 7 Home Premium 64 bit SP1 installation disk (burned from the pcworld links) Gparted Live CD Linux Mint 13 live cd A system backup (from the morning before this catastrophe) made using the Windows Backup and Restore. I put it on an external drive...that should be safe for now.

    Read the article

  • Ubuntu Newbie Needs Assistance!!

    - by Steve Greene
    New Ubuntu User Needs Help!- version 9.10 does not communicate with laptop Hello folks, Several days ago, I installed Ubuntu 9.10 onto my Acer Aspire 3100 laptop, running it alongside Widows Vista as a dual-bootable system. Creation of the Ubuntu boot CD went fine, and the installation onto my hard drive was flawless. Ubuntu opens and behaves as I would expect, except for one little problem. For reasons unknown to me, Ubuntu is not communicating with my laptop's networking hardware, and I have no internet connectivity, even when sitting directly under the wireless router at the local library (literally), which puts out a wickedly-fast signal that my Windows Vista OS auto-detects and immediately connects to. Up in the right side of the Ubuntu desktop, I click on the network icon and it does not show a wireless connection at all, even though I am only a few feet from the router. At home, where I use a dialup modem, I also see no means of getting online. My modem is an HDAUDIO Soft Data Fax Modem with Smart CP,manufactured by CXT (Conexant Systems Inc., file version 4.0.13.0, and the driver version is 7.58.0.0). I desparately wish to convert to Ubuntu. I used Mac for ten years, and then Windows for ten years. Now, after 20 years, I want to live out my days as an open-source Ubuntu fanatic. I am ready to give the old status quo the boot! I am an advanced computer user, but I am not a programmer. I seek a solution that is user-friendly for normal people, something equivalent to a driver that I can easily install or activate that will allow Ubuntu to see my hardware and get me connected. Can anyone help me over this hopefully-little glitch so that I can move on in total Ubuntu bliss? My processor is a Mobile AMD Sempron Processor 3500+ at 1.80 GHz, 1.50 GB RAM, and a 32-bit Operating System. I am running Windows Vista Home Basic, Service Pack 2. My current email is [email protected] if you have a workable solution that does not require programmer status to implement. Surely this must be a simple fix that I simply am overlooking, but being the new guy on the block, I have yet to be enlightened. Thanks for your help in coming up to speed!! Steve Wanna' be Ubuntu Fanatic "If you're not living on the edge, you're taking up too much space."

    Read the article

  • networking tunnel adapter connections?

    - by Karthik Balaguru
    I understand that Tunnel Adapter LAN is for encapsulating IPv6 packets with an IPv4 header so that they can be sent across an IPv4 network. Few queries popped up in my mind based on this :- If i do 'ipconfig', Apart from ethernet adapter LAN details, I get a series of statments as below - Tunnel adapter Local Area Connection* 6 Tunnel adapter Local Area Connection* 7 Tunnel adapter Local Area Connection* 12 Tunnel adapter Local Area Connection* 13 Tunnel adapter Local Area Connection* 14 Tunnel adapter Local Area Connection* 15 Tunnel adapter Local Area Connection* 16 Except for the *16, all the other Tunnel Adapter Local Area Connections show Media Disconnected. Why is the numbering for the Tunnel adapter LAN not sequential? It is like 6, 7, 12, 13, 14, 15, 16. A strange numbering scheme! I tried to figure it out by thinking of some arithmetic series. But, it does not seem to fit in. There is a huge gap between 7 and 12. Any ideas? What is the need for so many Tunnel Adapter LAN connections? Can you tell me a scenario that requires all of those ? I did ipconfig /all to get more information. From the listing, I understand that: 16, 15, 14, 12 are Microsoft 6to4 Adapters 13, 6 are isatap Adapters 7 is Teredo Tunneling Pseudo-interface I understand that the above are for automatic tunneling so that the tunnel endpoints are determined automatically by the routing infrastructure. 6to4 is recommended by RFC3056 for automatic tunneling that uses protocol 41 for encapsulation. It is typically used when an end-user wants to connect to the IPv6 Internet using their existing IPv4 connection. Teredo is an automatic tunneling technique that uses UDP encapsulation across multiple NATs. That is, It is to grant IPv6 connectivity to nodes that are located behind IPv6-unaware NAT devices ISATAP treats the IPv4 network as a virtual IPv6 local link, with mappings from each IPv4 address to a link-local IPv6 address. That is to transmit IPv6 packets between dual-stack nodes on top of an IPv4 network. That is, to put in simple words, ISATAP is an intra-site mechanism, while the 6to4 and Teredo are for inter-site tunnelling mechanisms. It seems that Teredo should alone enabled by default in Vista, But my system does not show it to be enabled by default. Interestingly, it shows a 6to4 tunnel adapter (Tunnel adapter LAN connection 16) to be enabled by default? Any specific reasons for it? If i do ipconfig /all, why is only one Teredo present while four 6to4 are present ? I searched the internet for answers to the above queries, but I am unable to find clear answers.

    Read the article

  • Optimal setup for ASUS P6X58D Premium BIOS (no OC)?

    - by rumtscho
    Normally, I'd trust the mainboard manufacturer to choose the best options as defaults. But I had trouble with the board, because even with Quick Boot enabled, it booted twice as slowly as a Pentium 4 Celeron. Then I changed lots of options at once (most of them weren't explained in the manual, just mentioned with a single sentence) and the boot time is only marginally worse than the Pentium 4 (54 sec against 46 sec from button to pw entering screen). Now I don't know if I have turned something off which should have stayed on. I guess I even won't be able to boot from a CD now, because even though it is present in the boot sequence, I took off a timeout I think it needs to check whether there is a disk in the drive. The second reason is that I don't have an internal HDD, only a SSD. I forgot my sources blush but I am under the impression that today's BIOS and OS options are geared toward booting from a HDD, which is often less than optimal when one boots from a SSD, especially when there are functions which cause avoidable writing cycles, as a SSD wears out after too many writing cycles. Most of the things I've read concern the OS, but there are some BIOS-relevant options too. I am especially confused about the disk mode. The board supports AHCI, IDE-simulation and RAID, but of the different articles I've read, there is a proponent for each and no clear arguments for any. So can one tell me which options are important in general and which are important for a SSD-only system? I don't want to overclock the CPU, so you don't have to say anything about this (yes I know the board is meant for OC:)). I am thinking of overclocking the RAM, since they sold me 1600er heatsinked modules which are running at 1066 now, but I'm not sure yet about that. The rest of the system: i7-930, Intel X25-m G2, 6 GB RAM, GTS 250, some no-name Blue-ray ROM. 2 external HDDs over USB 2.0. Lots of other USB-connected hardware (12 devices I think), no SATA 3 drives (will disabling the controller have an impact on performance?), no LAN, only WiFi. Lucid Lynx 64 bit, no dual boot, no virtual installations. The main uses of the system are: managing and playing/showing all the media stored on the external disks, lots of image manipulation, some video editing, a bit of (non-demanding) gaming, rarely development. Lots of Internet surfing too, but this shouldn't have much impact on performance.

    Read the article

  • Windows 7 The boot selection failed because a required device is inaccessible 0xc000000f

    - by piratejackus
    I have a problem with my Windows 7, hardware : Acer 3820TG Operating Systems : Windows 7 and Ubuntu 10.04 dual Case: When I try to boot my windows 7 I see an error: "Window failed to start. A recent hardware or software change might be the cause. To fix the problem: 1.Insert.... 2. .... ... status : 0xc000000f info : The boot selection failed because a required device is inaccessible .... " I can't exactly remember what were my last actions on Windows. I already searched this error and applied the proposed solutions, I created a repair USB (because I don't have a CD-ROM nor a Windows 7 CD) such as; -repair operating system :it says it cannot repair it -checking disk (chkdsk D: /f /r) : it checks the disk without a problem or error and it takes pretty long (more than a hour). But when I restart, still the same error. -I didn't create a restore point so I pass this option -I don't have a system image -I tried to run windows recovery (I have a recovery partition) but there are just two options: 1- Format the operating system but retain user data (copies the files under users to c\backup folder, but when I searched deeper I found that there are some people who already tried this option and couldn't find their user files under backup directory). Plus, I have unfortunately just one partition D (it is a fault I know) because I use always Ubuntu. So this is not applicable in my situation 2- Format entire system (Windows). I keep my valuable data in windows but not in user folder. I was reaching them from Windows. -I tried to repair windows boot by: bootrec /fixMBR bootrec /fixBoot bootrec /rebuildBCD I lost all grub menu, and reinstalled it. - ubuntuforums.org/showthread.php?t=1014708&page=29 nothing changed, same error. I created a thread in microsoft forums - http://social.answers.microsoft.com/Forums/en-US/w7install/thread/69517faf-850a-45fd- 8195-6d4ed831f805 but I couldn't find a solution. Before I run chkdsk from usb repair disk I couldn't able to mount Windows (NTFS) partition from Ubuntu, I was getting "couldn't mount file system, error code 2". I tried to fix ntfs partition from ubuntu and got "segmentation fault". I also created a thread on ubuntuforums for this mount problem: - http://ubuntuforums.org/showthread.php?t=1606427 So, after chkdsk, I could enable to mount windows partition but all I see in this partition is chkdsk logs, no any other data. Now, I don't think I lost my data because I don't get any filesystem errors, just the boot section, but this log files under windows partition makes me afraid. I see that Microsoft developers don't have a solution yet for this error. If you need any information to get more idea I can give, maybe I miss some points or it could be complicated. Thanks in advance.

    Read the article

  • Vagrant - Failed login, ssh not set up

    - by motleydev
    This question is two fold because somewhere in my attempts to solve the problem, I created a new one. First: I was trying to vagrant up using a Vagranfile based on the standard hashicorp/precise32 box. Everything worked up until default: SSH auth method: private key where it would eventually time out. Enabling gui in the Vagrantfile showed that the machine never actually logs in. I can use the standard user/pass and log in from that point but the vagrant up process still remains at that prior status. Here's where my understanding might be a little dim. I've tried setting auth method from the insecure_pass_key to my root ~/.ssh/id_rsa or whichever one I wanted to use. I'm not entirely sure where to put a copy of the public key or my authorized keys file. I've got a .vagrant.d folder in my user dir (I'm on OSX) which seems to contain the box images. I've got a .vagrant folder in my directory with the Vagrantfile which seems to contain the specific machine I am building off of. I've tried pouring over the docs and forums but I seem to be missing a key concept here. And Now: After a host of tips/tricks such as rolling back by VirtualBox install, uninstalling/reinstalling Vagrant and VritualBox several times, when I try to run vagrant ssh-config with a Vagrantfile based on the same hashicorp/precise32 it says that the box is not enabled for SSH. Specifically, this error: The provider for this Vagrant-managed machine is reporting that it is not yet ready for SSH. Depending on your provider this can carry different meanings. Make sure your machine is created and running and try again. Additionally, check the output of `vagrant status` to verify that the machine is in the state that you expect. If you continue to get this error message, please view the documentation for the provider you're using. So now I am slightly up a creek. Any help would be appreciated if not just clarifying a concept. Some pertinent info: I'm on OSX Maverics Due to the fact I'm running a dual HD system with system files on one HD and user files on another, my permissions are a little wonky and VBoxManage will only let me run commands via Sudo - not sure if it's pertinent - but maybe. I have no idea what I'm doing. That part is perhaps more important.

    Read the article

  • networking tunnel adapter connections?

    - by Karthik Balaguru
    I understand that Tunnel Adapter LAN is for encapsulating IPv6 packets with an IPv4 header so that they can be sent across an IPv4 network. Few queries popped up in my mind based on this :- If i do 'ipconfig', Apart from ethernet adapter LAN details, I get a series of statments as below - Tunnel adapter Local Area Connection* 6 Tunnel adapter Local Area Connection* 7 Tunnel adapter Local Area Connection* 12 Tunnel adapter Local Area Connection* 13 Tunnel adapter Local Area Connection* 14 Tunnel adapter Local Area Connection* 15 Tunnel adapter Local Area Connection* 16 Except for the *16, all the other Tunnel Adapter Local Area Connections show Media Disconnected. Why is the numbering for the Tunnel adapter LAN not sequential? It is like 6, 7, 12, 13, 14, 15, 16. A strange numbering scheme! I tried to figure it out by thinking of some arithmetic series. But, it does not seem to fit in. There is a huge gap between 7 and 12. Any ideas? What is the need for so many Tunnel Adapter LAN connections? Can you tell me a scenario that requires all of those ? I did ipconfig /all to get more information. From the listing, I understand that: 16, 15, 14, 12 are Microsoft 6to4 Adapters 13, 6 are isatap Adapters 7 is Teredo Tunneling Pseudo-interface I understand that the above are for automatic tunneling so that the tunnel endpoints are determined automatically by the routing infrastructure. 6to4 is recommended by RFC3056 for automatic tunneling that uses protocol 41 for encapsulation. It is typically used when an end-user wants to connect to the IPv6 Internet using their existing IPv4 connection. Teredo is an automatic tunneling technique that uses UDP encapsulation across multiple NATs. That is, It is to grant IPv6 connectivity to nodes that are located behind IPv6-unaware NAT devices ISATAP treats the IPv4 network as a virtual IPv6 local link, with mappings from each IPv4 address to a link-local IPv6 address. That is to transmit IPv6 packets between dual-stack nodes on top of an IPv4 network. That is, to put in simple words, ISATAP is an intra-site mechanism, while the 6to4 and Teredo are for inter-site tunnelling mechanisms. It seems that Teredo should alone enabled by default in Vista, But my system does not show it to be enabled by default. Interestingly, it shows a 6to4 tunnel adapter (Tunnel adapter LAN connection 16) to be enabled by default? Any specific reasons for it? If i do ipconfig /all, why is only one Teredo present while four 6to4 are present ? I searched the internet for answers to the above queries, but I am unable to find clear answers.

    Read the article

  • JNDI Datasource Problem on Tomcat 6, Hibernate

    - by Asuman AKYILDIZ
    Hello; I am using Tomcat 6 as application server, Struts-Hibernate and MyEclipse 6.0. My application uses JDBC driver but I should modify it to use JNDI Datasource. I followed steps as described in tomcat 6.0 howto tutorial. I defined my resource in tomcatconf: <Resource name="jdbc/ats" global="jdbc/ats" auth="Container" type="javax.sql.DataSource" driverClassName="oracle.jdbc.OracleDriver" url="jdbc:oracle:thin:@//localhost:1521/MISDEV" username="TEST" password="TEST" maxActive="20" maxIdle="10" maxWait="-1" validationQuery="SELECT 1 from dual" removeAbandoned="true" removeAbandonedTimeout="30" logAbandoned="false"/> I gave reference in my application web.xml: <resource-ref> <description>Oracle Datasource example</description> <res-ref-name>jdbc/ats</res-ref-name> <res-type>javax.sql.DataSource</res-type> <res-auth>Container</res-auth> </resource-ref> And I defined datasource-dialect in my hibernate-cfg.xml <property name="connection.datasource">java:comp/env/jdbc/ats</property> <property name="dialect">org.hibernate.dialect.Oracle9Dialect</property> But when I create hibernate session, it can not open the connection: 09:18:11,322 ERROR JDBCExceptionReporter:72 - Connections could not be acquired from the underlying database! org.hibernate.exception.GenericJDBCException: Cannot open connection I also tried to set the properties at runtime: Configuration configuration = new Configuration(); configuration.setProperty("hibernate.dialect", "org.hibernate.dialect.Oracle9Dialect"); //configuration.setProperty("hibernate.connection.datasource", "java:comp/env/jdbc/ats"); configuration.setProperty("hibernate.current_session_context_class", "thread"); configuration.setProperty("hibernate.connection.provider_class", "org.hibernate.connection.C3P0ConnectionProvider"); configuration.setProperty("hibernate.show_sql", "true"); sessionFactory = configuration.configure().buildSessionFactory(); It does not open connection again. But, when I use JDBC driver it works: Configuration configuration = new Configuration(); configuration.setProperty("hibernate.dialect", "org.hibernate.dialect.Oracle9Dialect"); //configuration.setProperty("hibernate.connection.datasource", "java:comp/env/jdbc/ats"); configuration.setProperty("hibernate.connection.url", "jdbc:oracle:thin:@//localhost:1521/MISDEV"); configuration.setProperty("hibernate.connection.username", "test"); configuration.setProperty("hibernate.connection.password", "test"); configuration.setProperty("hibernate.connection.driver_class", "oracle.jdbc.OracleDriver"); configuration.setProperty("hibernate.transaction.factory_class", "org.hibernate.transaction.JDBCTransactionFactory"); configuration.setProperty("hibernate.current_session_context_class", "thread"); configuration.setProperty("hibernate.connection.provider_class", "org.hibernate.connection.C3P0ConnectionProvider"); configuration.setProperty("hibernate.show_sql", "true"); sessionFactory = configuration.configure().buildSessionFactory(); I have been searching for 3 days and no success. What may be de problem?

    Read the article

  • Disk IO causing high load on Xen/CentOS guest

    - by Peter Lindqvist
    I'm having serious issues with a xen based server, this is on the guest partition. It's a paravirtualized CentOS 5.5. The following numbers are taken from top while copying a large file over the network. If i copy the file another time the speed decreases in relation to load average. So the second time it's half the speed of the first time. It needs some time to cool off after this. Load average slowly decreases until it's once again usable. ls / takes about 30 seconds. top - 13:26:44 up 13 days, 21:44, 2 users, load average: 7.03, 5.08, 3.15 Tasks: 134 total, 2 running, 132 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.1%sy, 0.0%ni, 25.3%id, 74.5%wa, 0.0%hi, 0.0%si, 0.1%st Mem: 1048752k total, 1041460k used, 7292k free, 3116k buffers Swap: 2129912k total, 40k used, 2129872k free, 904740k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 1506 root 10 -5 0 0 0 S 0.3 0.0 0:03.94 cifsd 1 root 15 0 2172 644 556 S 0.0 0.1 0:00.08 init Meanwhile the host is ~0.5 load avg and steady over time. ~50% wait Server hardware is dual xeon, 3gb ram, 170gb scsi 320 10k rpm, and shouldn't have any problems with copying files over the network. disk = [ "tap:aio:/vm/dev01.img,xvda,w" ] I also get these in the log INFO: task syslogd:1350 blocked for more than 120 seconds. "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. syslogd D 00062E4F 2208 1350 1 1353 1312 (NOTLB) c0ef0ed0 00000286 6e71a411 00062e4f c0ef0f18 00000009 c0f20000 6e738bfd 00062e4f 0001e7ec c0f2010c c181a724 c1abd200 00000000 ffffffff c0ef0ecc c041a180 00000000 c0ef0ed8 c03d6a50 00000000 00000000 c03d6a00 00000000 Call Trace: [<c041a180>] __wake_up+0x2a/0x3d [<ee06a1ea>] log_wait_commit+0x80/0xc7 [jbd] [<c043128b>] autoremove_wake_function+0x0/0x2d [<ee065661>] journal_stop+0x195/0x1ba [jbd] [<c0490a32>] __writeback_single_inode+0x1a3/0x2af [<c04568ea>] do_writepages+0x2b/0x32 [<c045239b>] __filemap_fdatawrite_range+0x66/0x72 [<c04910ce>] sync_inode+0x19/0x24 [<ee09b007>] ext3_sync_file+0xaf/0xc4 [ext3] [<c047426f>] do_fsync+0x41/0x83 [<c04742ce>] __do_fsync+0x1d/0x2b [<c0405413>] syscall_call+0x7/0xb ======================= I have tried disabling irqbalanced as suggested here but it does not seem to make any difference.

    Read the article

  • Why is my new Phenom II 965 BE not significantly faster than my old Athlon 64 X2 4600+?

    - by Software Monkey
    I recently rebuilt my 5 year old computer. I upgraded all core components, in particular from an Athlon 64 X2 4600+ at 2.4 GHz with DDR2 800 to a Phenom II 965 BE (quad core) at 3.6 GHz with DDR3 1333 (actually 1600, but testing consistently detected memory errors at 1600). The motherboard is also much newer and better. The HDD's (x3), DVD writer and card reader are the same. The BIOS memory config is auto-everything except the base timing which I overrode to 1T instead of 2T. The BIOS CPU multiplier is slightly over-clocked to 3.6 GHz from the stock 3.4 GHz. I noticed compiling Java is slower than I expected. As it happens I have some (single-threaded) Java pattern-matching code which is CPU and memory bound and for which I have performance numbers recorded on a number of hardware platforms, including my old system. So I did a test run on the new equipment and was stunned to find that the numbers are only slightly better than my old system, about 25%. The data set it is operating on is a 148,975 character array, which should easily fit in caches, but in any event the new CPU has larger caches all around. The system was, of course, otherwise idle for the test and the test run is a timed 10 seconds to eliminate scheduling anomalies. A long while ago, when I upgraded only memory from DD2 667 to DDR2 800 there was no change in performance of this test, which subjectively supports that the test cycle does not need to (significantly) access main memory, but yes it is creating and garbage collecting a large number of objects in the process of this test (low millions of matches are found for the pattern set). I am about 99.999% certain the code hasn't changed since I last ran it on 2009-03-17 - but I can't easily retest the old hardware, because it is currently in pieces on my work-bench waiting to be built into a new computer for my kids. Note that Windows (XP) reports a CPU speed of 795 MHz unless I have some thing running. With stuff running it seems to jump all over the place each time I use ALT-Pause to display the system properties, everywhere from 795 MHz to 3.4 Ghz. So why might my shiny new hardware under-performing so badly? EDIT: The old memory was Mushkin DDR2 800 with timings set for auto which should have been 5-5-5-12. The new memory is Corsair DDR3 1600, running at 1333 with timings also auto which are 9-9-9-21. In both cases they are a paired set of dual channel DIMMs. I was waiting to ensure my system was stable before tweaking with memory timings.

    Read the article

  • 64-bit linux kernel only seeing 3 of 4GB after upgrade...

    - by Blaine
    Hey everyone. I am running Ubuntu 9.04 64-bit on my macbook. I had 2GB of ram before, and everything ran great. I just upgraded to 2x2GB (4GB), but my system only sees 3GB of it. OS X, which I am dual booting, sees all 4GB. Also, my video performance is incredibly lacking. Before the upgrade my compiz benchmark was full at 80fps, and now it is at 22fps with very choppy window dragging. Has anyone ever heard of this on a 64-bit kernel? I just don't quite understand what could be the issue. 10$ uname -a Linux macbook 2.6.28-15-generic #49-Ubuntu SMP Tue Aug 18 19:25:34 UTC 2009 x86_64 GNU/Linux $ free -m total used free shared buffers cached Mem: 2953 1031 1921 0 114 427 -/+ buffers/cache: 489 2463 Swap: 7812 0 7812 9$ lsmod Module Size Used by i915 77960 2 drm 123232 3 i915 binfmt_misc 18572 1 ppdev 16904 0 btusb 21784 2 bridge 63776 0 stp 11140 1 bridge bnep 22912 2 vboxnetadp 109356 0 vboxnetflt 116972 0 vboxdrv 1721612 1 vboxnetflt uvcvideo 69640 0 compat_ioctl32 18304 1 uvcvideo videodev 45184 2 uvcvideo,compat_ioctl32 v4l1_compat 23940 2 uvcvideo,videodev lp 19588 0 parport 49584 2 ppdev,lp snd_hda_intel 557492 3 snd_pcm_oss 52352 0 snd_mixer_oss 24960 1 snd_pcm_oss snd_pcm 99464 2 snd_hda_intel,snd_pcm_oss arc4 10240 2 snd_seq_dummy 11524 0 ecb 11392 2 snd_seq_oss 41984 0 snd_seq_midi 15744 0 snd_rawmidi 33920 1 snd_seq_midi snd_seq_midi_event 16512 2 snd_seq_oss,snd_seq_midi snd_seq 66272 6 snd_seq_dummy,snd_seq_oss,snd_seq_midi,snd_seq_midi_event ath9k 310584 0 snd_timer 34064 2 snd_pcm,snd_seq snd_seq_device 16276 5 snd_seq_dummy,snd_seq_oss,snd_seq_midi,snd_rawmidi,snd_seq mac80211 251528 1 ath9k iTCO_wdt 21712 0 iTCO_vendor_support 12420 1 iTCO_wdt joydev 20992 0 video 29204 0 snd 78920 15 snd_hda_intel,snd_pcm_oss,snd_mixer_oss,snd_pcm,snd_seq_oss,snd_rawmidi,snd_seq,snd_timer,snd_seq_device applesmc 37700 0 output 11648 1 video soundcore 16800 1 snd pcspkr 11136 0 cfg80211 43680 1 mac80211 appletouch 19972 0 isight_firmware 11520 0 input_polldev 12688 1 applesmc intel_agp 39408 1 snd_page_alloc 18704 2 snd_hda_intel,snd_pcm led_class 13064 2 ath9k,applesmc hid_apple 15872 0 usbhid 47040 0 ohci1394 42164 0 ieee1394 108288 1 ohci1394 sky2 63364 0 fbcon 49792 0 tileblit 11264 1 fbcon font 17024 1 fbcon bitblit 14464 1 fbcon softcursor 10368 1 bitblit Some information from dmesg: [ 795.820163] ACPI: EC: GPE storm detected, transactions will use polling mode [ 1762.709516] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 1763.078130] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 2362.760889] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 2416.352084] ACPI: EC: missing confirmations, switch off interrupt mode. [ 3718.721095] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 3719.108914] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 4318.773266] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 9513.813066] CE: hpet increasing min_delta_ns to 15000 nsec [ 9693.815684] npviewer.bin[6736]

    Read the article

  • lacp, cicso 3550, 3560, help with configuration

    - by Flamewires
    Hey all this is a repost from a question I asked on the cisco forums but never got a useful reply. Hey I'm trying to convert the FreeBSD servers at work to dual-gig lagg links from regular gigabit links. Our production servers are on a 3560. I have a small test environment on a 3550. I have achieved fail-over, but am having troubles achieving the speed increase. All servers are running gig intel (em) cards. The configs for the servers are: BSDServer: #!/bin/sh #bring up both interfaces ifconfig em0 up media 1000baseTX mediaopt full-duplex ifconfig em1 up media 1000baseTX mediaopt full-duplex #create the lagg interface ifconfig lagg0 create #set lagg0's protocol to lacp, add both cards to the interface, #and assign it em1's ip/netmask ifconfig lagg0 laggproto lacp laggport em0 laggport em1 ***.***.***.*** netmask 255.255.255.0 The switches are configured as follows: #clear out old junk no int Po1 default int range GigabitEthernet 0/15 - 16 # config ports interface range GigabitEthernet 0/15 - 16 description lagg-test switchport duplex full speed 1000 switchport access vlan 192 spanning-tree portfast channel-group 1 mode active channel-protocol lacp **** switchport trunk encapsulation dot1q **** no shutdown exit interface Port-channel 1 description lagginterface switchport access vlan 192 exit port-channel load-balance src-mac end obviously change 1000's to 100's and GigabitEthernet to FastEthernet for the 3550's config, as that switch has 100Mbit speed ports. With this config on the 3550, I get failover and 92Mbits/sec speed on both links, simultaneously, connecting to 2 hosts.(tested with iperf) Success. However this is only with the "switchport trunk encapsulation dot1q" line. First, I do not understand why I need this, I thought it was only for connecting switches. Is there some other setting which this turns on that is actually responsible for the speed increase? Second, This config does not work on the 3560. I get failover, but not the speed increase. Speeds drop from gig/sec to 500Mbit/sec when I make 2 simultaneous connections to the server with or without the encapsulation line. I should mention that both switches are using source-mac load balancing. In my test I am using Iperf. I have the server(lagg box) setup as the server(iperf -s), and the client computers are client(iperf -c server-ip-address), so the source mac(and IP) are different for both connections. Any ideas/corrections/questions would be helpful, as the gig switches are what I actually need the lagg links on. Ask if you need more information.

    Read the article

  • No login prompt displayed after updating Ubuntu 10.04, broken gdm

    - by cliff
    So here's what happens: I updated my system the other day, was prompted for a reboot for the update to complete but was in the middle of working so I delayed it until after I was done. I reboot and it's broken :(. It appears to boot normally, with the following exceptions: The purple Ubuntu load screen no longer displays (though it did for the first couple of times I tried to get in). I hear the login prompt sound, but no login prompt appears. Nor is it simply "invisible" - pressing enter, typing my password, and pressing enter again do nothing. Normally my Bluetooth mouse is functional at this point, but it is not. GRUB displays recovery options for my current kernel, and for an older one (2.6.32-24). Trying to boot into .32-24 gives me an error saying "udevadm can't do something while udev is not configured". So I try solutions listed here: http://superuser.com/questions/195786/ubuntu-update-went-wrong-pc-doesnt-boot-how-can-i-repair-it Nothing I tried seemed to work, and after further Googling my hunch is that it's a problem with gdm. Please correct me if I'm wrong, I don't know all that much about how Linux/Ubuntu systems work just yet. Things I'm able to do: Boot to a live CD Ctrl-Alt-F2 after that login sound plays brings me to a console login, which I can successfully do (it's how I tried the solutions above). This works only under the current kernel. A hack I'd be willing to explore is removing the login prompt from the console, but I'd prefer to "simply" fix what's wrong. Like that guy, I need to repair the system rather than reinstall. System: Dell Inspiron 1525 Core 2 Duo Proprietary Driver for Broadcom 43xx wireless Dual-boot with Windows 7 (which is how I'm posting this, unfortunately I only have this machine and any experimenting requires constant reboots into Windows/brokenbuntu) Last package installed was Moonlight, but it appeared to install properly. Kernel: 2.6.32-25 Edit: After working with Karl's suggestions, it seems that the problem is with gdm. Error exit status 245 when attempting to sudo apt-get install --reinstall gdm, also an error processing gdm when running sudo apt-get -f install. How do I reinstall or repair gdm so that I can get back into my machine?

    Read the article

  • Why might one host be unable to access the Internet, when it can ping the router and when all other hosts can?

    - by user1444233
    I have a Draytek Vigor 2830n. It's kicking out a 192.168.3.0 LAN. It performs load-balancing across dual-WAN ports, although I've turned off the second WAN to simplify testing. There are many hosts on the LAN. All IPs are allocated through DHCP, most freely allocated from the pool, but one or two are bound to NIC MAC addresses. All hosts can access the Internet, save one. That host (192.168.3.100 or 'dot100' for short) gets allocated an IP address (and the right gateway address, DNS server addresses, subnet etc.) dot100 can ping itself. It can ping the gateway, and access the latter's web interface via port 80. It's responsive and loss-free (sustained ping over a couple of minutes reports no data loss). Yet, for some reason that evades me, dot100 can't ping an external IP address or domain name. I suspect it's never been able to, because it was getting some Internet access from a second adaptor (different subnet), but that's now been turned off, which exposed the problem. In dot100, I've tried: two operating systems (Windows 8 and Knoppix), to rule out anti-virus programs etc. two physical adaptors two cables, on each adaptor two IPs (e.g. .100 and .103 assigned by Mac and .26 from the pool) both dynamic and assigned (MAC-bound) DHCP-allocated IPs but none of this experiments yielded any variation in the result. dot100 is a crucial host. It's a file server for the network, so I need it to be reliably allocated a consistent IP. Can anyone offer a potential solution or a way forward with the analysis please? My guess My analysis so far leads me to believe it's a router issue. I've checked the web interface very carefully. There are no filters setup in Firewall - General Setup or Filter Setup. I suspect it's a corrupted internal routing table, but the web UI shows this as the Routing table: Key: C - connected, S - static, R - RIP, * - default, ~ - private * 0.0.0.0/ 0.0.0.0 via 62.XX.XX.X WAN1 * 62.XX.XX.X/ 255.255.255.255 via 62.XX.XX.X WAN1 S 82.YY.YYY.YYY/ 255.255.255.255 via 82.YY.YYY.YYY WAN1 C 192.168.1.0/ 255.255.255.0 directly connected WAN2 C~ 192.168.3.0/ 255.255.255.0 directly connected LAN2

    Read the article

  • New monitor connected to HDMI adaptor doesn't show output after booting

    - by Paul
    Hello out there in the multiple monitors’ world. I am a very old newbie in your world and need help. I just purchased a new Asus VH236H monitor and hooked it up the HDMI port of an ATI Radeon HD4300 / 4500 Series display adaptor. I left the old Princeton LCD19 (TMDS) hooked up to the DVI port of the same display adaptor. Both monitors displayed the boot sequence, after I fired good old Sarastro2 (Asus P5Q Pro Turbo – Dual Core E5300 – 2.60 GHz) up. The Asus lacked one half of a second behind the Princeton until the Windows 7 Ultimate SP 1 boot up was complete. Then the Asus displayed “HDMI NO SIGNAL” and went into hibernation. The Princeton stayed lit up as before. Both monitors are displayed on the “Screen Resolution Setup Display” and I plaid around with them for a while. The only thing I accomplished was to shove the desktop icons from the Princeton to the still hibernating Asus. The “Multiple displays:” is set to “Extend these displays”, the Orientation is “Landscape” and the Resolutions are set on both to the “recommended” one. Both monitors show that they work properly in the advanced Properties display. What am I doing wrong, what am I missing? Never mind the opinions about the different resolutions of the two monitors. I always can unhook the Princeton and give it to a Goodwill Store if I do not like the setup. I just would like to make it work. Any constructive help is very much appreciated, Thank you. Thank you Anees Bakrain Only the ATI Radeon HD 4300/4500 Series adapter is displayed in the Device Manager, for that reason I have to assume that the onboard display adaptor is not active. All 40 drivers of Sarastro2 are up to date and the HDMI cable can not be the problem because both monitors displayed the boot sequence up to the moment when Windows 7 was loaded completely. This was the moment, when the Asus monitor lost its signal. Both connectors, HDMI and DVI are connected and removing the DVI connector would not solve my problem of running both monitors simultaneously. However, your suggestions shifted my seventy one year old brain into the next gear. The only question remaining is; “Why the signals to the Asus monitor stop after the sequence is complete”. The ATI Radeon HD 4300/4500 Series adapter seems to be capable of sending simultaneous HDMI and DVI signals, what is done during the boot sequence. Why do the signals change after the boot sequence is complete is the key question or der springende Punkt? Is this a correct assumption slhck?

    Read the article

  • JNDI Datasource definition in Tomcat 6.0

    - by romaintaz
    I want to define a DataSource to an Oracle database on my Tomcat 6.0. So, in conf/server.xml (yes, I know that this DataSource will be available for all the webapps in Tomcat, but it's not a problem here), I've set this Resource: <GlobalNamingResources> <Resource name="hibernate/HibernateDS" auth="Container" type="javax.sql.DataSource" url="jdbc:oracle:thin:@myserver:1542:foo" username="foo" password="bar" driverClassName="oracle.jdbc.OracleDriver" maxActive="50" maxIdle="10" validationQuery="select 1 from dual"/> Then, in the web.xml of my application, I set a resource-ref element: <resource-ref> <description>Hibernate Datasource</description> <res-ref-name>hibernate/HibernateDS</res-ref-name> <res-type>javax.sql.DataSource</res-type> <res-auth>Container</res-auth> </resource-ref> Finally, as Hibernate is used to manage the database connection, I have a webapps/mywebapp/WEB-INF/classes/hibernate.cfg.xml that creates a session-factory using the JNDI DataSource: <hibernate-configuration> <session-factory> <property name="connection.datasource">java:comp/env/hibernate/HibernateDS</property> ... However, when I start my Tomcat server, I get an error that says it could not create the INFO [net.sf.hibernate.util.NamingHelper] JNDI InitialContext properties:{} INFO [net.sf.hibernate.connection.DatasourceConnectionProvider] Using datasource: java:comp/env/hibernate/HibernateDS INFO [net.sf.hibernate.transaction.TransactionFactoryFactory] Transaction strategy: net.sf.hibernate.transaction.JDBCTransactionFactory INFO [net.sf.hibernate.transaction.TransactionManagerLookupFactory] No TransactionManagerLookup configured (in JTA environment, use of process level read-write cache is not recommended) WARN [net.sf.hibernate.cfg.SettingsFactory] Could not obtain connection metadata org.apache.tomcat.dbcp.dbcp.SQLNestedException: Cannot create JDBC driver of class '' for connect URL 'null' at org.apache.tomcat.dbcp.dbcp.BasicDataSource.createDataSource(BasicDataSource.java:1150) at org.apache.tomcat.dbcp.dbcp.BasicDataSource.getConnection(BasicDataSource.java:880) at net.sf.hibernate.connection.DatasourceConnectionProvider.getConnection(DatasourceConnectionProvider.java:59) at net.sf.hibernate.cfg.SettingsFactory.buildSettings(SettingsFactory.java:84) at net.sf.hibernate.cfg.Configuration.buildSettings(Configuration.java:1172) ... Caused by: java.lang.NullPointerException at sun.jdbc.odbc.JdbcOdbcDriver.getProtocol(JdbcOdbcDriver.java:507) at sun.jdbc.odbc.JdbcOdbcDriver.knownURL(JdbcOdbcDriver.java:476) at sun.jdbc.odbc.JdbcOdbcDriver.acceptsURL(JdbcOdbcDriver.java:307) at java.sql.DriverManager.getDriver(DriverManager.java:253) at org.apache.tomcat.dbcp.dbcp.BasicDataSource.createDataSource(BasicDataSource.java:1143) ... 11 more Do you have any idea why Hibernate is not able to construct the session-factory? What is wrong in my configuration?

    Read the article