  • LVM mirror attempt results in "Insufficient free space"

    - by MattK
    Attempting to add a disk to mirror an LVM volume on CentOS 7 always fails with "Insufficient free space: 1 extents needed, but only 0 available". Having searched for a solution, I have tried specifying disks, multiple logging options, adding 3rd log partition, but have not found a solution Not sure if I am making a rookie mistake, or there is something more subtle wrong (I am more familiar with ZFS, new to using LVM): # lvconvert -m1 centos_bi/home Insufficient free space: 1 extents needed, but only 0 available # lvconvert -m1 --corelog centos_bi/home Insufficient free space: 1 extents needed, but only 0 available # lvconvert -m1 --corelog --alloc anywhere centos_bi/home Insufficient free space: 1 extents needed, but only 0 available # lvconvert -m1 --mirrorlog mirrored --alloc anywhere centos_bi/home /dev/sda2 Insufficient free space: 1 extents needed, but only 0 available # lvconvert -m1 --corelog --alloc anywhere centos_bi/home /dev/sdi2 /dev/sda2 Insufficient free space: 1 extents needed, but only 0 available The two disks are of the same size, and have identical partition layouts via "sfdisk -d /dev/sdi part_table; sfdisk /dev/sda < part_table". The current configuration is detailed below. # pvs PV VG Fmt Attr PSize PFree /dev/sda1 centos_bi lvm2 a-- 496.00m 496.00m /dev/sda2 centos_bi lvm2 a-- 465.27g 465.27g /dev/sdi2 centos_bi lvm2 a-- 465.27g 0 # vgs VG #PV #LV #SN Attr VSize VFree centos_bi 3 3 0 wz--n- 931.02g 465.75g # lvs -a -o +devices LV VG Attr LSize Pool Origin Data% Move Log Cpy%Sync Convert Devices home centos_bi -wi-ao---- 391.64g /dev/sdi2(6050) root centos_bi -wi-ao---- 50.00g /dev/sdi2(106309) swap centos_bi -wi-ao---- 23.63g /dev/sdi2(0) # pvdisplay --- Physical volume --- PV Name /dev/sdi2 VG Name centos_bi PV Size 465.27 GiB / not usable 3.00 MiB Allocatable yes (but full) PE Size 4.00 MiB Total PE 119109 Free PE 0 Allocated PE 119109 --- Physical volume --- PV Name /dev/sda2 VG Name centos_bi PV Size 465.27 GiB / not usable 3.00 MiB Allocatable yes PE Size 4.00 MiB Total PE 119109 Free PE 119109 Allocated PE 0 --- Physical volume --- PV Name /dev/sda1 VG Name centos_bi PV Size 500.00 MiB / not usable 4.00 MiB Allocatable yes PE Size 4.00 MiB Total PE 124 Free PE 124 Allocated PE 0 # vgdisplay --- Volume group --- VG Name centos_bi System ID Format lvm2 Metadata Areas 3 Metadata Sequence No 10 VG Access read/write VG Status resizable MAX LV 0 Cur LV 3 Open LV 3 Max PV 0 Cur PV 3 Act PV 3 VG Size 931.02 GiB PE Size 4.00 MiB Total PE 238342 Alloc PE / Size 119109 / 465.27 GiB Free PE / Size 119233 / 465.75 GiB # lvdisplay --- Logical volume --- LV Path /dev/centos_bi/swap LV Name swap VG Name centos_bi LV Write Access read/write LV Creation host, time localhost, 2014-08-07 16:34:34 -0400 LV Status available # open 2 LV Size 23.63 GiB Current LE 6050 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:1 --- Logical volume --- LV Path /dev/centos_bi/home LV Name home VG Name centos_bi LV Write Access read/write LV Creation host, time localhost, 2014-08-07 16:34:35 -0400 LV Status available # open 1 LV Size 391.64 GiB Current LE 100259 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:2 --- Logical volume --- LV Path /dev/centos_bi/root LV Name root VG Name centos_bi LV Write Access read/write LV Creation host, time localhost, 2014-08-07 16:34:37 -0400 LV Status available # open 1 LV Size 50.00 GiB Current LE 12800 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0

    Read the article

  • Ubuntu suddenly freezes

    - by tapan
    I've a strange problem with my ubuntu 10.04 installation. Whenever i boot into ubuntu the entire system freezes / hangs soon after (~ 2 mins in). This problem exists on my windows 7 installation too. However if i start World of Warcraft or Warcraft on windows it doesnt hang for the duration i'm playing the game. After i stop playing and exit the game my laptop hangs inside 2 mins. Here is when it gets weirder. If i disconnect the charger, the laptop doesn't hang. However when I start it in ubuntu recovery mode and drop to root shell and use the 'startx' command everything works perfectly. I cannot figure out what the problem is. i have an intel core2duo 2.2ghz processor, intel mobile 965 graphics, 2 GB RAM for more details here is the output of cat /proc/cpuinfo : processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 15 model name : Intel(R) Core(TM)2 Duo CPU T7500 @ 2.20GHz stepping : 11 cpu MHz : 2201.000 cache size : 4096 KB physical id : 0 siblings : 2 core id : 0 cpu cores : 2 apicid : 0 initial apicid : 0 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 10 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm constant_tsc arch_perfmon pebs bts pni dtes64 monitor ds_cpl vmx est tm2 ssse3 cx16 xtpr pdcm lahf_lm ida tpr_shadow vnmi flexpriority bogomips : 4389.80 clflush size : 64 power management: processor : 1 vendor_id : GenuineIntel cpu family : 6 model : 15 model name : Intel(R) Core(TM)2 Duo CPU T7500 @ 2.20GHz stepping : 11 cpu MHz : 2201.000 cache size : 4096 KB physical id : 0 siblings : 2 core id : 1 cpu cores : 2 apicid : 1 initial apicid : 1 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 10 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm constant_tsc arch_perfmon pebs bts pni dtes64 monitor ds_cpl vmx est tm2 ssse3 cx16 xtpr pdcm lahf_lm ida tpr_shadow vnmi flexpriority bogomips : 4388.96 clflush size : 64 power management: here is the output of cat /proc/meminfo MemTotal: 2052440 kB MemFree: 55924 kB Buffers: 579352 kB Cached: 821752 kB SwapCached: 704 kB Active: 897124 kB Inactive: 1032256 kB Active(anon): 412140 kB Inactive(anon): 264804 kB Active(file): 484984 kB Inactive(file): 767452 kB Unevictable: 0 kB Mlocked: 0 kB HighTotal: 1178440 kB HighFree: 6012 kB LowTotal: 874000 kB LowFree: 49912 kB SwapTotal: 995988 kB SwapFree: 986616 kB Dirty: 8928 kB Writeback: 0 kB AnonPages: 527596 kB Mapped: 76536 kB Slab: 39480 kB SReclaimable: 21100 kB SUnreclaim: 18380 kB PageTables: 5672 kB NFS_Unstable: 0 kB Bounce: 0 kB WritebackTmp: 0 kB CommitLimit: 2022208 kB Committed_AS: 1856400 kB VmallocTotal: 122880 kB VmallocUsed: 11928 kB VmallocChunk: 104644 kB HugePages_Total: 0 HugePages_Free: 0 HugePages_Rsvd: 0 HugePages_Surp: 0 Hugepagesize: 4096 kB DirectMap4k: 16376 kB DirectMap4M: 892928 kB Also the kern.log doesn't show any errors. What I want to know is what might be the problem, how i could test for it and if there are any solutions I could try. Thanks :).

    Read the article

  • SQL Server 2008 Recovery Mode reverts from FULL to SIMPLE

    - by Eric Hazen
    Three of our SQL databases have their recovery model change every night from FULL to SIMPLE. The only jobs that I'm aware of are two BackupExec jobs that run nightly. Why would the recovery model change? Backup Jobs: SQL FULL BACKUP, SQL LOG BACKUP Event Manager: Event 5084: Setting Database option RECOVERY to SIMPLE for database databaseName

    Read the article

  • Configuring RAID1 on HP Proliant Microserver N54L / Ubuntu 14.04.1 LTS [duplicate]

    - by Chris Beach
    This question already has an answer here: Cant find my harddrives in ubuntu installation? 2 answers I've bought a N54L and fitted two 3GB drives. Keen to get set up with RAID1. BIOS: SATA controller mode set to "RAID" RAID Option ROM utility: both physical drives set up as one logical drive When I came to install Ubuntu (14.04.1), both drives appeared during the setup process. I was only expecting to see the logical drive, although I'm a complete novice with RAID. I've read that the HP Proliant Microservers don't have "proper" RAID support, and require some kind of driver to be installed. I've tried a few HP utilities from the following apt repo: deb http://downloads.linux.hp.com/SDR/repo/mcp wheezy/current non-free On installation, most say "server not supported" Would appreciate your advice.

    Read the article

  • Disk is spinning down each minute, unable to disable it

    - by lzap
    I played with spindown and APM settings of my Samsung discs and now they spin down every minute. I want to disable it, but it seems it does not accept any of the spindown time or APM values. Nothing works, it's all the same. Please help what values should be proper for it. I do not want it to spin down at all. /dev/sda: ATA device, with non-removable media Model Number: SAMSUNG HD154UI Serial Number: S1Y6J1KZ206527 Firmware Revision: 1AG01118 Standards: Used: ATA-8-ACS revision 3b Supported: 7 6 5 4 Configuration: Logical max current cylinders 16383 16383 heads 16 16 sectors/track 63 63 -- CHS current addressable sectors: 16514064 LBA user addressable sectors: 268435455 LBA48 user addressable sectors: 2930277168 Logical/Physical Sector size: 512 bytes device size with M = 1024*1024: 1430799 MBytes device size with M = 1000*1000: 1500301 MBytes (1500 GB) cache/buffer size = unknown Capabilities: LBA, IORDY(can be disabled) Queue depth: 32 Standby timer values: spec'd by Standard, no device specific minimum R/W multiple sector transfer: Max = 16 Current = 16 Advanced power management level: 60 Recommended acoustic management value: 254, current value: 0 DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 udma5 *udma6 udma7 Cycle time: min=120ns recommended=120ns PIO: pio0 pio1 pio2 pio3 pio4 Cycle time: no flow control=120ns IORDY flow control=120ns Commands/features: Enabled Supported: * SMART feature set Security Mode feature set * Power Management feature set * Write cache * Look-ahead * Host Protected Area feature set * WRITE_BUFFER command * READ_BUFFER command * NOP cmd * DOWNLOAD_MICROCODE * Advanced Power Management feature set Power-Up In Standby feature set * SET_FEATURES required to spinup after power up SET_MAX security extension Automatic Acoustic Management feature set * 48-bit Address feature set * Device Configuration Overlay feature set * Mandatory FLUSH_CACHE * FLUSH_CACHE_EXT * SMART error logging * SMART self-test Media Card Pass-Through * General Purpose Logging feature set * 64-bit World wide name * WRITE_UNCORRECTABLE_EXT command * {READ,WRITE}_DMA_EXT_GPL commands * Segmented DOWNLOAD_MICROCODE * Gen1 signaling speed (1.5Gb/s) * Gen2 signaling speed (3.0Gb/s) * Native Command Queueing (NCQ) * Host-initiated interface power management * Phy event counters * NCQ priority information DMA Setup Auto-Activate optimization Device-initiated interface power management * Software settings preservation * SMART Command Transport (SCT) feature set * SCT Long Sector Access (AC1) * SCT LBA Segment Access (AC2) * SCT Error Recovery Control (AC3) * SCT Features Control (AC4) * SCT Data Tables (AC5) Security: Master password revision code = 65534 supported not enabled not locked frozen not expired: security count supported: enhanced erase 326min for SECURITY ERASE UNIT. 326min for ENHANCED SECURITY ERASE UNIT. Logical Unit WWN Device Identifier: 50024e900300cca3 NAA : 5 IEEE OUI : 0024e9 Unique ID : 00300cca3 Checksum: correct I have the very same disc which I did not "tuned" and it does not spin. But I do not know where to read the settings from. The hdparm only shows this: Advanced power management level: 60 Recommended acoustic management value: 254, current value: 0 Edit: It seems the issue was tuned daemon in RHEL6. It was too aggressive, I turned off disc tuning and it seems they are no longer spinning down.

    Read the article

  • Ubuntu/Windows suddenly freezes

    - by tapan
    I've a strange problem with my ubuntu 10.04 installation. Whenever i boot into ubuntu the entire system freezes / hangs soon after (~ 2 mins in). This problem exists on my windows 7 installation too. However if i start World of Warcraft or Warcraft on windows it doesnt hang for the duration i'm playing the game. After i stop playing and exit the game my laptop hangs inside 2 mins. Here is when it gets weirder. If i disconnect the charger, the laptop doesn't hang. However when I start it in ubuntu recovery mode and drop to root shell and use the 'startx' command everything works perfectly. I cannot figure out what the problem is. i have an intel core2duo 2.2ghz processor, intel mobile 965 graphics, 2 GB RAM for more details here is the output of cat /proc/cpuinfo : processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 15 model name : Intel(R) Core(TM)2 Duo CPU T7500 @ 2.20GHz stepping : 11 cpu MHz : 2201.000 cache size : 4096 KB physical id : 0 siblings : 2 core id : 0 cpu cores : 2 apicid : 0 initial apicid : 0 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 10 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm constant_tsc arch_perfmon pebs bts pni dtes64 monitor ds_cpl vmx est tm2 ssse3 cx16 xtpr pdcm lahf_lm ida tpr_shadow vnmi flexpriority bogomips : 4389.80 clflush size : 64 power management: processor : 1 vendor_id : GenuineIntel cpu family : 6 model : 15 model name : Intel(R) Core(TM)2 Duo CPU T7500 @ 2.20GHz stepping : 11 cpu MHz : 2201.000 cache size : 4096 KB physical id : 0 siblings : 2 core id : 1 cpu cores : 2 apicid : 1 initial apicid : 1 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 10 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm constant_tsc arch_perfmon pebs bts pni dtes64 monitor ds_cpl vmx est tm2 ssse3 cx16 xtpr pdcm lahf_lm ida tpr_shadow vnmi flexpriority bogomips : 4388.96 clflush size : 64 power management: here is the output of cat /proc/meminfo MemTotal: 2052440 kB MemFree: 55924 kB Buffers: 579352 kB Cached: 821752 kB SwapCached: 704 kB Active: 897124 kB Inactive: 1032256 kB Active(anon): 412140 kB Inactive(anon): 264804 kB Active(file): 484984 kB Inactive(file): 767452 kB Unevictable: 0 kB Mlocked: 0 kB HighTotal: 1178440 kB HighFree: 6012 kB LowTotal: 874000 kB LowFree: 49912 kB SwapTotal: 995988 kB SwapFree: 986616 kB Dirty: 8928 kB Writeback: 0 kB AnonPages: 527596 kB Mapped: 76536 kB Slab: 39480 kB SReclaimable: 21100 kB SUnreclaim: 18380 kB PageTables: 5672 kB NFS_Unstable: 0 kB Bounce: 0 kB WritebackTmp: 0 kB CommitLimit: 2022208 kB Committed_AS: 1856400 kB VmallocTotal: 122880 kB VmallocUsed: 11928 kB VmallocChunk: 104644 kB HugePages_Total: 0 HugePages_Free: 0 HugePages_Rsvd: 0 HugePages_Surp: 0 Hugepagesize: 4096 kB DirectMap4k: 16376 kB DirectMap4M: 892928 kB Also the kern.log doesn't show any errors. What I want to know is what might be the problem, how i could test for it and if there are any solutions I could try. Thanks :).

    Read the article

  • How to get ASUS UEFI BIOS EZ Mode utility on my asus laptop?

    - by Manoj Kumar
    i have asus laptop with the following specs: Manufacturer ASUSTeK Computer Inc. Model K53SC (CPU 1) Version 1.0 Chipset Vendor IntelBIOS Brand American Megatrends Inc. Version K53SC.208 Chipset Model Sandy Bridge BIOS Brand American Megatrends Inc. Version K53SC.208 Operating System MS Windows 7 Ultimate 64-bit In the BIOS setting i have enabled 'UEFI' but im not unable to see the graphical interface of UEFI.

    Read the article

  • virsh XML interface allocation

    - by Kaushik Koneru
    I am trying to launch VM using a XML. This VM will be having 5 interfaces each connected to certain bridge. Issue here is allocation of these interfaces is random. My XML <interface type='bridge'> <mac address='52:54:00:9f:14:b3'/> <source bridge='br0'/> <target dev='vnet1'/> <model type='e1000'/> <alias name='net0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:9f:14:b4'/> <source bridge='br1'/> <target dev='vnet2'/> <model type='e1000'/> <alias name='net1'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x10' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:9f:14:b5'/> <source bridge='br2'/> <target dev='vnet2'/> <model type='e1000'/> <alias name='net3'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x12' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:9f:14:c4'/> <source bridge='br3'/> <target dev='vnet3'/> <model type='e1000'/> <alias name='net4'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x18' function='0x0'/> </interface> Allocation of interfaces are random mean e th6 will be connected to br3 ; eth7 -- br4 eth8 -- br2 eth9 -- br0. Is there any way to make it static?? At the same time is there anyway of assigning IP Address to these eth interfaces through XML file itself??

    Read the article

  • LUKS with LVM, mount is not persistent after reboot

    - by linxsaga
    I have created a Logical vol and used luks to encrypt it. But while rebooting the server. I get a error message (below), therefore I would have to enter the root pass and disable the /etc/fstab entry. So mount of the LUKS partition is not persistent during reboot using LUKS. I have this setup on RHEL6 and wondering what i could be missing. I want to the LV to get be mount on reboot. Later I would want to replace it with UUID instead of the device name. Error message on reboot: "Give root password for maintenance (or type Control-D to continue):" Here are the steps from the beginning: [root@rhel6 ~]# pvcreate /dev/sdb Physical volume "/dev/sdb" successfully created [root@rhel6 ~]# vgcreate vg01 /dev/sdb Volume group "vg01" successfully created [root@rhel6 ~]# lvcreate --size 500M -n lvol1 vg01 Logical volume "lvol1" created [root@rhel6 ~]# lvdisplay --- Logical volume --- LV Name /dev/vg01/lvol1 VG Name vg01 LV UUID nX9DDe-ctqG-XCgO-2wcx-ddy4-i91Y-rZ5u91 LV Write Access read/write LV Status available # open 0 LV Size 500.00 MiB Current LE 125 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0 [root@rhel6 ~]# cryptsetup luksFormat /dev/vg01/lvol1 WARNING! ======== This will overwrite data on /dev/vg01/lvol1 irrevocably. Are you sure? (Type uppercase yes): YES Enter LUKS passphrase: Verify passphrase: [root@rhel6 ~]# mkdir /house [root@rhel6 ~]# cryptsetup luksOpen /dev/vg01/lvol1 house Enter passphrase for /dev/vg01/lvol1: [root@rhel6 ~]# mkfs.ext4 /dev/mapper/house mke2fs 1.41.12 (17-May-2010) Filesystem label= OS type: Linux Block size=1024 (log=0) Fragment size=1024 (log=0) Stride=0 blocks, Stripe width=0 blocks 127512 inodes, 509952 blocks 25497 blocks (5.00%) reserved for the super user First data block=1 Maximum filesystem blocks=67633152 63 block groups 8192 blocks per group, 8192 fragments per group 2024 inodes per group Superblock backups stored on blocks: 8193, 24577, 40961, 57345, 73729, 204801, 221185, 401409 Writing inode tables: done Creating journal (8192 blocks): done Writing superblocks and filesystem accounting information: done This filesystem will be automatically checked every 21 mounts or 180 days, whichever comes first. Use tune2fs -c or -i to override. [root@rhel6 ~]# mount -t ext4 /dev/mapper/house /house PS: HERE I have successfully mounted: [root@rhel6 ~]# ls /house/ lost+found [root@rhel6 ~]# vim /etc/fstab -> as follow /dev/mapper/house /house ext4 defaults 1 2 [root@rhel6 ~]# vim /etc/crypttab -> entry as follows house /dev/vg01/lvol1 password [root@rhel6 ~]# mount -o remount /house [root@rhel6 ~]# ls /house/ lost+found [root@rhel6 ~]# umount /house/ [root@rhel6 ~]# mount -a -> SUCCESSFUL AGAIN [root@rhel6 ~]# ls /house/ lost+found Please let me know if I am missing anything here. Thanks in advance.

    Read the article

  • “Disk /dev/xvda1 doesn't contain a valid partition table”

    - by Simpanoz
    Iam newbie to EC2 and Ubuntu 11 (EC2 Free tier Ubuntu). I have made following commands. sudo mkfs -t ext4 /dev/xvdf6 sudo mkdir /db sudo vim /etc/fstab /dev/xvdf6 /db ext4 noatime,noexec,nodiratime 0 0 sudo mount /dev/xvdf6 /db fdisk -l I got following output. Can some one guide me what I am doing wrong and how it can be rectified. Disk /dev/xvda1: 8589 MB, 8589934592 bytes 255 heads, 63 sectors/track, 1044 cylinders, total 16777216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/xvda1 doesn't contain a valid partition table Disk /dev/xvdf6: 6442 MB, 6442450944 bytes 255 heads, 63 sectors/track, 783 cylinders, total 12582912 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/xvdf6 doesn't contain a valid partition table.

    Read the article

  • Can't connect disk management to remote XP PC from local Win7/Server 2008

    - by Grez
    Scenario as follows: support technicians using Windows 7 PC's or Server 2008 terminal server are unable to connect Disk Management MMC snap in to a remote PC when the remote device is running Windows XP. "Disk management could not start Virtual Disk Service (VDS) on ". This can happen if the remote computer does not support VDS, or if a connection cannot be established because it was blocked by Windows Firewall." Connecting from another XP machine or 2003 server to the same XP machines works fine. Even connecting from XP/2003 to the Win7 or 2008 server works fine. Windows firewall disabled on all devices. I'm guessing this is something to do with the fact that XP uses logical disk manager service whereas Win7/2008 use Virtual disk manager service. But there doesn't seem to be any way to use logical disk manager service from 7/2008 to connect to XP...

    Read the article

  • One Database vs. Multiple Databases

    - by Ricardo
    I need to design a system which represents multiple "projects", one per client in SQL Server , something similar to StackExchange... same data model, different sites (one per customer). Each project has the same data model, but is independent of all others. My inclination is to use one database to store all projects. What is your recommendation?

    Read the article

  • Tomcat - Persistent Object

    - by David
    I am running a servlet that recommends items based on a data model. The data model has to be loaded into an object from a database each time user makes a request to the sever and since the data is the same for all the users I would like this object to be loaded once only. I am very new to Tomcat and don't know where to look so any advice will be appreciated. Thanks!

    Read the article

  • Does it make sense to install an SSD into a 3rd generation MacBook?

    - by Ivan Krechetov
    I've heard that, to really benefit from a solid-state drive, one needs a motherboard fast enough. Do you think it's worth to install an SSD into this laptop? Model Name: MacBook Model Identifier: MacBook3,1 Processor Name: Intel Core 2 Duo Processor Speed: 2.2 GHz Number Of Processors: 1 Total Number Of Cores: 2 L2 Cache: 4 MB Memory: 4 GB Bus Speed: 800 MHz Boot ROM Version: MB31.008E.B02

    Read the article

  • RAID P410i and P812 performance issues

    - by Alexey
    I'm having much trouble with I/O performance of HP DL360 server with two RAID controllers - P410i and P812, Windows Server 2008, 36 GiB RAM and 16 x Intel Xeon x5550. The server runs a bunch of tasks producing heavy sequential I/O, and after about 20-30 minutes of intensive work it looks like the tasks are stuck, not using CPU and with enough free memory (so this cannot be a bottleneck). The same tasks were running quite well on the older server (Windows Server 2003, 4 x Intel Xeon, 12 GiB RAM). RAID cache is present, write-cache battery is installed. Cache is configured as 25% readahead/75% writeback. The swap file resides on the logical disk served by P410i and other logical disks are on P812. Can someone tell me what can be the matter of this? Is this a hardware problem or misconfiguration?

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • Server-to-Switch Trunking in Procurve switch, what does this mean?

    - by MattUebel
    I am looking to set up switch redundancy in a new datacenter environment. IEEE 802.3ad seems to be the go-to concept on this, at least when paired with a technology that gets around the "single switch" limitation for the link aggregation. Looking through the brochure for a procurve switch I see: Server-to-Switch Distributed Trunking, which allows a server to connect to two switches with one logical trunk; increases resiliency and enables load sharing in virtualized data centers http://www.procurve.com/docs/products/brochures/5400_3500%20Product%20Brochure4AA0-4236ENW.pdf I am trying to figure out how this relates to the 802.3a standard, as it seems that it would give me what I want (one server has 2 nics, each of which is connected to separate switches, together forming a single logical nic which would provide the happy redundancy we want), but I guess I am looking for someone familiar with this concept and could add to it.

    Read the article

  • What is "2LUN" mode in connection with RAID?

    - by naxa
    I've came across RAID products that also list JBOD (just a bunch of disks) mode and 2LUN mode. What the heck is 2LUN mode? I could not find a description; the closest thing seems to be LUN 'logical unit number' but I don't get the 2LUN thing. UPDATE 1 This is what Wikipedia has to say about JBOD: JBOD (derived from "just a bunch of disks"): an architecture involving multiple hard drives, while making them accessible either as independent hard drives, or as a combined (spanned) single logical volume with no actual RAID functionality. So JBOD can actually mean two different (albeit related) things. Answer of Guest says 2LUN means no spanning. Does this suggest that 2LUN would simply mean the JBOD-variant with no span?

    Read the article

  • Xeon X3220 Dual-Core 2.4 GHz - which march setting for gcc?

    - by hurikhan77
    Should I use -march=nocona or -march=core2 when compiling binaries for this processor with gcc 4.3? vendor_id : GenuineIntel cpu family : 6 model : 15 model name : Intel(R) Xeon(R) CPU X3220 @ 2.40GHz stepping : 8 cpuid level : 10 flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss syscall nx lm constant_tsc arch_perfmon pebs bts rep_good pni ssse3 cx16 lahf_lm I cannot really find if this CPU is already core2 architecture... Only find information about the quad core variants, but this CPU is only dual core.

    Read the article

  • High I/O latency with software RAID, LUKS encrypted and LVM partitioned KVM setup

    - by aef
    I found out a performance problems with a Mumble server, which I described in a previous question are caused by an I/O latency problem of unknown origin. As I have no idea what is causing this and how to further debug it, I'm asking for your ideas on the topic. I'm running a Hetzner EX4S root server as KVM hypervisor. The server is running Debian Wheezy Beta 4 and KVM virtualisation is utilized through LibVirt. The server has two different 3TB hard drives as one of the hard drives was replaced after S.M.A.R.T. errors were reported. The first hard disk is a Seagate Barracuda XT ST33000651AS (512 bytes logical, 4096 bytes physical sector size), the other one a Seagate Barracuda 7200.14 (AF) ST3000DM001-9YN166 (512 bytes logical and physical sector size). There are two Linux software RAID1 devices. One for the unencrypted boot partition and one as container for the encrypted rest, using both hard drives. Inside the latter RAID device lies an AES encrypted LUKS container. Inside the LUKS container there is a LVM physical volume. The hypervisor's VFS is split on three logical volumes on the described LVM physical volume: one for /, one for /home and one for swap. Here is a diagram of the block device configuration stack: sda (Physical HDD) - md0 (RAID1) - md1 (RAID1) sdb (Physical HDD) - md0 (RAID1) - md1 (RAID1) md0 (Boot RAID) - ext4 (/boot) md1 (Data RAID) - LUKS container - LVM Physical volume - LVM volume hypervisor-root - LVM volume hypervisor-home - LVM volume hypervisor-swap - … (Virtual machine volumes) The guest systems (virtual machines) are mostly running Debian Wheezy Beta 4 too. We have one additional Ubuntu Precise instance. They get their block devices from the LVM physical volume, too. The volumes are accessed through Virtio drivers in native writethrough mode. The IO scheduler (elevator) on both the hypervisor and the guest system is set to deadline instead of the default cfs as that happened to be the most performant setup according to our bonnie++ test series. The I/O latency problem is experienced not only inside the guest systems but is also affecting services running on the hypervisor system itself. The setup seems complex, but I'm sure that not the basic structure causes the latency problems, as my previous server ran four years with almost the same basic setup, without any of the performance problems. On the old setup the following things were different: Debian Lenny was the OS for both hypervisor and almost all guests Xen software virtualisation (therefore no Virtio, also) no LibVirt management Different hard drives, each 1.5TB in size (one of them was a Seagate Barracuda 7200.11 ST31500341AS, the other one I can't tell anymore) We had no IPv6 connectivity Neither in the hypervisor nor in guests we had noticable I/O latency problems According the the datasheets, the current hard drives and the one of the old machine have an average latency of 4.12ms.

    Read the article

  • VMWare esxi 4.1 storage errors with MD3200

    - by Karl Katzke
    We're seeing some storage errors from the esxi logs relating to our MD3200. I'm sort of a VMWare noob and am not sure where to go from here because I couldn't find a lot of documentation on the VMWare website, and the forums didn't seem to have any posts about it with actual answers. Everything is working, but I'm trying to proactively troubleshoot this. sfcb-vmware_base|StoragePool Cannot get logical disk data from controller 0 sfcb-vmware_base|Volume Cannot get logical disk data from controller 0 sfcb-vmware_base|storelib-GetLDList-ProcessLibCommandCall failed; rval = 0x800E The ESXi boxes are connected directly via SAS to the controller on the MD3200. What do these errors actually mean, and what's a good path to start troubleshooting or solving them?

    Read the article

  • How to set up linux watchdog daemon with Intel 6300esb

    - by ACiD GRiM
    I've been searching for this on Google for sometime now and I have yet to find proper documentation on how to connect the kernel driver for my 6300esb watchdog timer to /dev/watchdog and ensure that watchdog daemon is keeping it alive. I am using RHEL compatible Scientific Linux 6.3 in a KVM virtual machine by the way Below is everything I've tried so far: dmesg|grep 6300 i6300ESB timer: Intel 6300ESB WatchDog Timer Driver v0.04 i6300ESB timer: initialized (0xffffc900008b8000). heartbeat=30 sec (nowayout=0) | ll /dev/watchdog crw-rw----. 1 root root 10, 130 Sep 22 22:25 /dev/watchdog | /etc/watchdog.conf #ping = 172.31.14.1 #ping = 172.26.1.255 #interface = eth0 file = /var/log/messages #change = 1407 # Uncomment to enable test. Setting one of these values to '0' disables it. # These values will hopefully never reboot your machine during normal use # (if your machine is really hung, the loadavg will go much higher than 25) max-load-1 = 24 max-load-5 = 18 max-load-15 = 12 # Note that this is the number of pages! # To get the real size, check how large the pagesize is on your machine. #min-memory = 1 #repair-binary = /usr/sbin/repair #test-binary = #test-timeout = watchdog-device = /dev/watchdog # Defaults compiled into the binary #temperature-device = #max-temperature = 120 # Defaults compiled into the binary #admin = root interval = 10 #logtick = 1 # This greatly decreases the chance that watchdog won't be scheduled before # your machine is really loaded realtime = yes priority = 1 # Check if syslogd is still running by enabling the following line #pidfile = /var/run/syslogd.pid Now maybe I'm not testing it correctly, but I would expecting that stopping the watchdog service would cause the /dev/watchdog to time out after 30 seconds and I should see the host reboot, however this does not happen. Also, here is my config for the KVM vm <!-- WARNING: THIS IS AN AUTO-GENERATED FILE. CHANGES TO IT ARE LIKELY TO BE OVERWRITTEN AND LOST. Changes to this xml configuration should be made using: virsh edit sl6template or other application using the libvirt API. --> <domain type='kvm'> <name>sl6template</name> <uuid>960d0ac2-2e6a-5efa-87a3-6bb779e15b6a</uuid> <memory unit='KiB'>262144</memory> <currentMemory unit='KiB'>262144</currentMemory> <vcpu placement='static'>1</vcpu> <os> <type arch='x86_64' machine='rhel6.3.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <cpu mode='custom' match='exact'> <model fallback='allow'>Westmere</model> <vendor>Intel</vendor> <feature policy='require' name='tm2'/> <feature policy='require' name='est'/> <feature policy='require' name='vmx'/> <feature policy='require' name='ds'/> <feature policy='require' name='smx'/> <feature policy='require' name='ss'/> <feature policy='require' name='vme'/> <feature policy='require' name='dtes64'/> <feature policy='require' name='rdtscp'/> <feature policy='require' name='ht'/> <feature policy='require' name='dca'/> <feature policy='require' name='pbe'/> <feature policy='require' name='tm'/> <feature policy='require' name='pdcm'/> <feature policy='require' name='pdpe1gb'/> <feature policy='require' name='ds_cpl'/> <feature policy='require' name='pclmuldq'/> <feature policy='require' name='xtpr'/> <feature policy='require' name='acpi'/> <feature policy='require' name='monitor'/> <feature policy='require' name='aes'/> </cpu> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/mnt/data/vms/sl6template.img'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </disk> <controller type='usb' index='0'> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x2'/> </controller> <interface type='bridge'> <mac address='52:54:00:44:57:f6'/> <source bridge='br0.2'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:88:0f:42'/> <source bridge='br1'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/> </interface> <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target type='serial' port='0'/> </console> <watchdog model='i6300esb' action='reset'> <address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/> </watchdog> <memballoon model='virtio'> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </memballoon> </devices> </domain> Any help is appreciated as the most I've found are patches to kvm and general softdog documentation or IPMI watchdog answers.

    Read the article