Search Results

Search found 21802 results on 873 pages for 'erx vb next coder'.

Page 165/873 | < Previous Page | 161 162 163 164 165 166 167 168 169 170 171 172  | Next Page >

  • How can a non-technical person can learn to write a spec for small projects?

    - by Joseph Turian
    How can a non-technical person learn to write specs for small projects? A friend of mine is trying to outsource some development on a statistics project. In particular, he does a lot of work in excel, and wants to outsource the creation of scripts to do what he now does by hand. However, my friend is extremely non-technical. He is poor at writing technical specs. When he does write a spec, it is written the way you would describe doing something in excel (go to this cell and then copy the value to that cell). It is also overly verbose, and does examples several times. I'm not sure if he properly describes corner cases. The first project he outsourced was a failure. I think he overdescribed some details, but underdescribed corner cases. That and/or the coder he hired didn't think through the corner cases and ask appropriate questions. I'm not sure. I got on IM with him and it took me half an hour to dig out a description that should have taken five minutes or less to describe. I wrote the scripts for him at the end, but didn't examine why his process with the coder failed. He has asked me for help. However, I refuse to get involved, because taking his spec and translating it into clear requirements is 10x more work than executing on a clearly written spec. What is the right way for him to learn? Are there resources he could use? Are there ways he can learn from small, low-pressure practice projects with coders? [edit: Most of his scripts are statistical and data processing oriented. e.g. take this column and run an average over it. Remove these rows under these conditions. So the challenge is different than spec'ing a web app.]

    Read the article

  • Multiple Jquery Cycle Slideshows with their own Navs

    - by daveredfern
    Hello, I am using the Jquery cycle plugin (http://malsup.com/jquery/cycle/) on a blog listing page. There are multiple slideshows which work fine but I'd like each on the have their own previous and next. Because these are blog posts it is difficult to sign unique IDs or classes. I currently have:- $('.article .gallery').cycle({ next: '.viewmore .left', prev: '.viewmore .right', timeout:0 }); I have tried the following but doesn't work. It gives you a better idea of what I am looking for:- $('.article .gallery').cycle({ next: $(this).next('.viewmore .left'), prev: $(this).next('.viewmore .right'), timeout:0 }); Can anyone help me? Thanks in advance. Dave.

    Read the article

  • Junior developer introduction to job industry

    - by lady_killer
    I am a junior developer at my second working experience, the first one using PHP with WordPress and currently on Groovy on Grails. I like coding, I attend meetup to discuss technology etc but I still did not understand how to become a real professional with the "know how" attitude. I read Clean Coder, the author advises to spend 20 hours per week of my spare time to learn new technologies and to keep myself up to date. I do not find this realistic, if you want to have a bit of a social life, and I also noticed that learning at work, at least in the places where I worked, is not ideal. No support from seniors for new projects, no pair programming and code reviews, no company trainings, one hour a week tech meetings where seniors walk away after a bit because they already know the topic discussed and so on. Sometimes is quite hard to keep the motivation... My questions are: Is our industry supposed to be like this? Is there real team working in the sense of sharing knowledge and help juniors to get up to speed? Are we supposed to learn new technologies or technology features just in our spare time?Clean Coder says football players do not train during official matches and our working hours are like official matches, we should just perform and learn in other moments. Is it really like this? How can I improve my skills with no support? Is it enough to read books and try out the exercises and perhaps some katas? In almost 5 month of Groovy on Grails experience at work, I have never had the opportunity to create anything from scratch, just worked on existing issues where it was even really difficult to get the domain knowledge from senior devs.

    Read the article

  • Compare GetNextInsertionPosition and GetNextContextPosition in WPF

    - by paradisonoir
    As I enter a character in my RichTextBox, I want to get the next character from the its TextRange. So here is how I do it: TextPointer ptr1= RichTextBox.CaretPosition; char nextChar = GetNextChar(); while (char.IsWhiteSpace(nextChar)) { ptr1= ptr1.GetNextInsertionPosition(LogicalDirection.Forward); nextChar = GetCharacterAt(Ptr1); } then I get the ptr1 of the next character and from the TextPointer, I get the TextRange, and do my changes. So here is the problem? when the next word is spelled correctly, I have no problem, but if it's not spelled properly then ptr1 would not point to the first character of the next word (the second character), and if I use GetNextContextPosition(LogicalDirection.Forward) it would give me the first letter of the next word if it's misspelled. So depending on the spelling only one of them works? I was just wondering if you have any idea about this problem? Is there anything wrong I am doing here?

    Read the article

  • Updating a database connection password using a script

    - by Tim Dexter
    An interesting customer requirement that I thought was worthy of sharing today. Thanks to James for the requirement and Bryan for the proposed solution and me for testing the solution and proving it works :0) A customers implementation of Sarbanes Oxley requires them to change all database account passwords every 90 days. This is scripted leveraging shell scripts today for most of their environments. But how can they manage the BI Publisher connections? Now, the customer is running 11g and therefore using weblogic on the middle tier, which is the first clue to Bryans proposed solution. To paraphrase and embellish Bryan's solution a little; why not use a JNDI connection from BIP to the database. Then employ the web logic scripting engine to make updates to the JNDI as needed? BIP is completely uninvolved and with a little 'timing' users will be completely unaware of the password updates i.e. change the password when reports are not being executed. Perfect! James immediately tracked down the WLST script that could be used here, http://middlewaremagic.com/weblogic/?p=4261 (thanks Ravish) Now it was just a case of testing the theory. Some steps: Create the JNDI connection in WLS Create the JNDI connection in BI Publisher pointing to the WLS connection Build new data models using or re-point data sources to use the JNDI connection. Create the WLST script to update the WLS JNDI password as needed. Test! Some details. Creating the JNDI connection in web logic is pretty straightforward. Log into hte console and look for Data Sources under the Services section of the home page and click it Click New >> Generic Datasource Give the connection a name. For the JNDI name, prefix it with 'jdbc/' so I have 'jdbc/localdb' - this name is important you'll need it on the BIP side. Select your db type - this will influence the drivers and information needed on the next page. Being a company man, Im using an Oracle db. Click Next Select the driver of choice, theres lots I know, you can read about them I just chose 'Oracle's Driver (Thin) for Instance connections; Versions 9.0.1 and later' Click Next >> Next Fill out the db name (SID), server, port, username to connect and password >> Next Test the config to ensure you can connect. >> Next Now you need to deploy the connection to your BI server, select it and click Next. You're done with the JNDI config. Creating the JNDI connection on the Publisher side is covered here. Just remember to the connection name you created in WLS e.g. 'jdbc/localdb' Not gonna tell you how to do this, go read the user guide :0) Suffice to say, it works. This requires a little reading around the subject to understand the scripting engine and how to execute scripts. Nicely covered here. However a bit of googlin' and I found an even easier way of running the script. ${ServerHome}/common/bin/wlst.sh updatepwd.py Where updatepwd.py is my script file, it can be in another directory. As part of the wlst.sh script your environment is set up for you so its very simple to execute. The nitty gritty: Need to take Ravish's script above and create a file with a .py extension. Its going to need some modification, as he explains on the web page, to make it work in your environment. I played around with it for a while but kept running into errors. The script as is, tries to loop through all of your connections and modify the user and passwords for each. Not quite what we are looking for. Remember our requirement is to just update the password for a given connection. I also found another issue with the script. WLS 10.x does not allow updates to passwords using clear type ie un-encrypted text while the server is in production mode. Its a bit much to set it back to developer mode bounce it, change the passwords and then bounce and then change back to production and bounce again. After lots of messing about I finally came up with the following: ############################################################################# # # Update password for JNDI connections # ############################################################################# print("*** Trying to Connect.... *****") connect('weblogic','welcome1','t3://localhost:7001') print("*** Connected *****") edit() startEdit() print ("*** Encrypt the password ***") en = encrypt('hr') print "Encrypted pwd: ", en print ("*** Changing pwd for LocalDB ***") dsName = 'LocalDB' print 'Changing Password for DataSource ', dsName cd('/JDBCSystemResources/'+dsName+'/JDBCResource/'+dsName+'/JDBCDriverParams/'+dsName) set('PasswordEncrypted',en) save() activate() Its pretty simple and you can expand on it to loop through the data sources and change each as needed. I have hardcoded the password into the file but you can pass it as a parameter as needed using the properties file method. Im not going to get into the detail of that here but its covered with an example here. Couple of points to note: 1. The change to the password requires a server bounce to get the changes picked up. You can add that to the shell script you will use to call the script above. 2. The script above needs to be run from the MW_HOME\user_projects\domains\bifoundation_domain directory to get the encryption libraries set correctly. My command to run the whole script was: d:\oracle\bi_mw\wlserver_10.3\common\bin\wlst.cmd updatepwd.py - where wlst.cmd is the scripting command line and updatepwd.py was my update password script above. I have not quite spoon fed everything you need to make it a robust script but at least you know you can do it and you can work out the rest I think :0)

    Read the article

  • Memento with optional state?

    - by Korey Hinton
    EDIT: As pointed out by Steve Evers and pdr, I am not correctly implementing the Memento pattern, my design is actually State pattern. Menu Program I built a console-based menu program with multiple levels that selects a particular test to run. Each level more precisely describes the operation. At any level you can type back to go back one level (memento). Level 1: Server Type? [1] Server A [2] Server B Level 2: Server environment? [1] test [2] production Level 3: Test type? [1] load [2] unit Level 4: Data Collection? [1] Legal docs [2] Corporate docs Level 4.5 (optional): Load Test Type [2] Multi TIF [2] Single PDF Level 5: Command Type? [1] Move [2] Copy [3] Remove [4] Custom Level 6: Enter a keyword [setup, cleanup, run] Design States PROBLEM: Right now the STATES enum is the determining factor as to what state is BACK and what state is NEXT yet it knows nothing about what the current memento state is. Has anyone experienced a similar issue and found an effective way to handle mementos with optional state? static enum STATES { SERVER, ENVIRONMENT, TEST_TYPE, COLLECTION, COMMAND_TYPE, KEYWORD, FINISHED } Possible Solution (Not-flexible) In reference to my code below, every case statement in the Menu class could check the state of currentMemo and then set the STATE (enum) accordingly to pass to the Builder. However, this doesn't seem flexible very flexible to change and I'm struggling to see an effective way refactor the design. class Menu extends StateConscious { private State state; private Scanner reader; private ServerUtils utility; Menu() { state = new State(); reader = new Scanner(System.in); utility = new ServerUtils(); } // Recurring menu logic public void startPromptingLoop() { List<State> states = new ArrayList<>(); states.add(new State()); boolean redoInput = false; boolean userIsDone = false; while (true) { // get Memento from last loop Memento currentMemento = states.get(states.size() - 1) .saveMemento(); if (currentMemento == null) currentMemento = new Memento.Builder(0).build(); if (!redoInput) System.out.println(currentMemento.prompt); redoInput = false; // prepare Memento for next loop Memento nextMemento = null; STATES state = STATES.values()[states.size() - 1]; // get user input String selection = reader.nextLine(); switch (selection) { case "exit": reader.close(); return; // only escape case "quit": nextMemento = new Memento.Builder(first(), currentMemento, selection).build(); states.clear(); break; case "back": nextMemento = new Memento.Builder(previous(state), currentMemento, selection).build(); if (states.size() <= 1) { states.remove(0); } else { states.remove(states.size() - 1); states.remove(states.size() - 1); } break; case "1": nextMemento = new Memento.Builder(next(state), currentMemento, selection).build(); break; case "2": nextMemento = new Memento.Builder(next(state), currentMemento, selection).build(); break; case "3": nextMemento = new Memento.Builder(next(state), currentMemento, selection).build(); break; case "4": nextMemento = new Memento.Builder(next(state), currentMemento, selection).build(); break; default: if (state.equals(STATES.CATEGORY)) { String command = selection; System.out.println("Executing " + command + " command on: " + currentMemento.type + " " + currentMemento.environment); utility.executeCommand(currentMemento.nickname, command); userIsDone = true; states.clear(); nextMemento = new Memento.Builder(first(), currentMemento, selection).build(); } else if (state.equals(STATES.KEYWORD)) { nextMemento = new Memento.Builder(next(state), currentMemento, selection).build(); states.clear(); nextMemento = new Memento.Builder(first(), currentMemento, selection).build(); } else { redoInput = true; System.out.println("give it another try"); continue; } break; } if (userIsDone) { // start the recurring menu over from the beginning for (int i = 0; i < states.size(); i++) { if (i != 0) { states.remove(i); // remove all except first } } reader = new Scanner(System.in); this.state = new State(); userIsDone = false; } if (!redoInput) { this.state.restoreMemento(nextMemento); states.add(this.state); } } } }

    Read the article

  • How to get z-index to play nice with the jQuery plugin Cycle

    - by alex
    Take a look at the bottom right example on the jQuery Cycle Advanced Demos page. Notice how when it loops the gallery, the next image goes beneath the last, as opposed to others where the next image always covers the previous one? Well, at least in Firefox 3.6.3. I'm developing a custom animation with jQuery cycle that has the same problem. When it loops, the next image goes under instead of over. This is my config object I pass to cycle(). { fx: 'custom', timeout: 5000, easing: 'easeInOutQuad', pause: 1, cssFirst: { zIndex: 0 }, cssBefore: { display: 'block', top: -500, opacity: 1, zIndex: 1 }, animIn: { top: 0, opacity: 1 }, animOut: { opacity: .2 }, cssAfter: { display: 'none', opacity: .2, zIndex: 0 }, delay: -1000 } Basically the animation is the same as the cover fx, except the previous image should fade away as the next one comes down on top. Is there any way to get the next slide when it loops to cover the previous one? Thanks

    Read the article

  • Java - Circular Garbage Collection

    - by aloh
    A <- B <- C <- D <- A... // A is firstNode, D is lastNode if ( length == 1 ) { firstNode = null; lastNode = null; firstNode.next = null; firstNode.prev = null; } else { Node secondNode = firstNode.next; Node secondToLast = lastNode.prev; firstNode.next = null; firstNode.prev = null; lastNode.next = null; lastNode.prev = null; secondNode.prev = null; secondToLast.next = null; firstNode = null; lastNode = null; } That should send everything in between as candidates for garbage collection, I hope?

    Read the article

  • F# pattern matching when mixing DU's and other values

    - by Roger Alsing
    What would be the most effective way to express the following code? match cond.EvalBool() with | true -> match body.Eval() with | :? ControlFlowModifier as e -> match e with | Break(scope) -> e :> obj //Break is a DU element of ControlFlowModifier | _ -> next() //other members of CFM should call next() | _ -> next() //all other values should call next() | false -> null cond.EvalBool returns a boolean result where false should return null and true should either run the entire block again (its wrapped in a func called next) or if the special value of break is found, then the loop should exit and return the break value. Is there any way to compress that block of code to something smaller?

    Read the article

  • Removing a node from a linked list

    - by lost_with_coding
    I would like to create a delete_node function that deletes the node at the location in the list as a count from the first node. So far this is the code I have: class node: def __init__(self): self.data = None # contains the data self.next = None # contains the reference to the next node class linked_list: def __init__(self): self.cur_node = None def add_node(self, data): new_node = node() # create a new node new_node.data = data new_node.next = self.cur_node # link the new node to the 'previous' node. self.cur_node = new_node # set the current node to the new one. def list_print(self): node = ll.cur_node while node: print node.data node = node.next def delete_node(self,location): node = ll.cur_node count = 0 while count != location: node = node.next count+=1 delete node ll = linked_list() ll.add_node(1) ll.add_node(2) ll.add_node(3) ll.list_print()

    Read the article

  • Slide navigation problem multiple div movement

    - by littleMan
    I have almost figured it out but still doesn't quite work the way i want it to. my problem is this part. It scrolls the first element to the left but the second element just appears and doesn't scroll does anyone know what todo here. var i = jQuery('.wikiform .wizard .view').size(); jQuery('.wikiform .navigation input[name^=Next]').click(function () { jQuery('.wikiform .wizard .view').each(function (j) { jQuery(this).animate({ marginLeft: -(current.next().width() * (i - j)) }, 750); /*line above Im having problems with ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ */ current = current.next(); j++; }); }); my complete code down below test it out and see what Im doing wrong (function ($) { $.fn.WikiForm = function (options) { this.Mode = options.mode || 'CancelOk' || 'Ok' || 'Wizard'; var current = jQuery('.wikiform .view:first'); function positionForm() { jQuery('body') .css('overflow-y', 'hidden'); jQuery('<div id="overlay"></div>') .insertBefore('.wikiform') .css('top', jQuery(document).scrollTop()) .animate({ 'opacity': '0.8' }, 'slow'); jQuery('.wikiform') .css('height', jQuery('.wikiform .wizard .view:first').height() + jQuery('.wikiform .navigation').height()) .css('top', window.screen.availHeight / 2 - jQuery('.wikiform').height() / 2) .css('width', jQuery('.wikiform .wizard .view:first').width()) .css('left', -jQuery('.wikiform').width()) .animate({ marginLeft: jQuery(document).width() / 2 + jQuery('.wikiform').width() / 2 }, 750); jQuery('.wikiform .wizard') .css('overflow', 'hidden') .css('height', jQuery('.wikiform .wizard .view:first').height()); } if (this.Mode == "Wizard") { return this.each(function () { positionForm(); //alert(current.next().width()); var i = jQuery('.wikiform .wizard .view').size(); jQuery('.wikiform .navigation input[name^=Next]').click(function () { jQuery('.wikiform .wizard .view').each(function (j) { jQuery(this).animate({ marginLeft: -(current.next().width() * (i - j)) }, 750); current = current.next(); j++; }); }); jQuery('.wikiform .navigation input[name^=Back]').click(function () { }); }); } else if (this.Mode == "CancelOk") { return this.each(function () { }); } else { return this.each(function () { }); } }; })(jQuery); $(document).ready(function () { jQuery(window).bind("load", function () { jQuery(".wikiform").WikiForm({ mode: 'Wizard', speed:750, ease:"expoinout" }); }); }); <style type="text/css"> body { margin:0px; } #overlay { background-color:Black; position:absolute; top:0; left:0; height:100%; width:100%; } .wikiform { background-color:Green; position:absolute; } .wikiform .wizard { clear: both; } .wizard { position: relative; left: 0; top: 0; width: 100%; list-style-type: none; } .wizard .view { float:left; } .view .form { } .navigation { float:right; clear:left } #view1 { background-color:Aqua; width:300px; height:300px; } #view2 { background-color:Fuchsia; width:300px; height:300px; } </style> <title></title></head><body><form action="" method=""><div id="layout"><div id="header"> Header </div> <div id="content" style="height:2000px"> Content </div> <div id="footer"> Footer </div> </div> <div id="formView1" class="wikiform"> <div class="wizard"> <div id="view1" class="view"> <div class="form"> Content 1 </div> </div> <div id="view2" class="view"> <div class="form"> Content 2 </div> </div> </div> <div class="navigation"> <input type="button" name="Back" value=" Back " /> <input type="button" name="Next " class="Next" value=" Next " /> <input type="button" name="Cancel" value="Cancel" /> </div> </div>

    Read the article

  • The Dreaded Startup Repair Loop on Win 7

    - by HighAltitudeCoder
    For most people, upgrading to Windows 7 has been a relatively painless process.  Not me.  I am in the unlucky 1% or less who had a somewhat less pleasant experience.  First, I cloned my entire onto a larger (and much faster) solid state hard drive, only experiencing minimal problems. Then, I bought the Retail version of Windows 7 Ultimate, took a deep breath and... oh yeah, I almost forgot - BACK UP THE COMPUTER.  The next morning I upgraded to Win 7 and everything seemed fine, until... I rebooted the system, the nice Windows 7 launch graphics come up, it's about to launch and AWWW, are you kidding me?!?!  Back to the BIOS splash screen?  Next comes the sequence of failure - attempt repair - unable to repair - do you want to wipe your hard drive decisions. Because I purchased the retail version, a number is provided where I could call Microsoft Tech support.  When I did, they instructed me to click "Install" from my installation CD, which did not work.  When I tried the "Upgrade" option, it reaches an impasse, telling you that yoiu have a newer version of Win 7, and thus cannot Upgrade.  If you choose "Install" you willl lose everything... files, programs, EVERYTHING.  Or at least this is what it tells you.  I was not willing to take the risk. To make things worse, I had installed a new antivirus software application before I realized my system was unstable (Trend Micro Titanium Internet Security), and this was causing additional problems. One interesting thing, and the only saving grace as it turns out, was that my system WOULD successfully reboot into the OS if I chose to restart it, rather than shut it down.  If I chose to shut down, I would have to go through the loop again until I was given the option to restart. As it turned out, I needed to update my BIOS.  I assumed that since I had updated my BIOS a long time ago to settings that were stable under Windows Vista Ultimate x64, I incorrectly expected Win 7 to adopt the same settings and didn't expect there to be any problems.  WRONG. My BIOS had a setting to halt the boot cycle if various kinds of errors were detected.  Windows Vista didn't care about this, but forget it under Windows 7.  I turned immediately corrected that BIOS setting.  Next, there were the two separate BIOS settings: enable USB mouse and enable USB keyboard.  The only sequence of events that would work were to start my reboot process over from stratch with a hard-wired non-usb keyboard and mouse.  Whent the system booted under these settings, it doesn't detect any errors due to either the mouse or keyboard, and actually booted for the first time in a long while (let me tell ya, that's an amazing experience after fiddling with settings for two entire weekends!) Next step: leave your old mouse and keyboard connected, but also connect your other two devices (mouse, keyboard) that use USB connections.  During the boot cycle, the operating system will not fail due to missing requirements during startup, and it will then pick up the new drivers necessary to use your new hardware. If you think you are in the clear here, you are wrong.  The next VERY IMPORTANT step is to remember to change your settings in the BIOS upon next startup.  Specifically, yoiu will need ot change your BIOS to enable USB mouse and enable USB keyboard input.  If you don't, Windows will detect an incompatibility upon the next startup, and you will be stuck once again in the endless cycle of reboot/Startup Repair/reboot/Startup Repair, without ever reaching a successful boot. Here's the thing - the BIOS and the drivers registered in Win 7 need to match.  If they don't, you're going to lose another weekend worrying and fiddling, all the while wondering if you've permanently damaged your hard drive beyond repair. (Sigh).  In the end, things worked out.  I must note that it is saddening to see how many posts there are out there that recommend just doing a clean install, as if it's the only option.  How many countless poor souls have lost their data, their backups, their pictures and videos, all for nothing other than the fact that the person giving advice just didn't know what to do at that point? My advice to you, try having a look at your BIOS settings first and making sure Win 7 can find your BIOS settings, and also disabling in your BIOS anything that might halt your system boot-up process if it encounters errors.

    Read the article

  • vba: a forever loop

    - by I__
    Sub something(tecan) On Error Resume Next Dim arr As New Collection, a Dim aFirstArray() As Variant Dim i As Long aFirstArray() = Array(Dir(tecan & "*.ESY", vbNormal)) aFirstArray(0) = Mid(aFirstArray(0), 1, 4) Do While Dir <> "" ReDim Preserve aFirstArray(UBound(aFirstArray) + 1) aFirstArray(UBound(aFirstArray)) = Mid(Dir, 1, 4) Loop On Error Resume Next For Each a In aFirstArray arr.Add a, a Next For i = 1 To arr.Count Cells(i, 1) = arr(i) 'open_esy (tecan & arr(i) & "*") Next Erase aFirstArray For i = 1 To arr.Count arr.Remove i Next i here is how i call this sub: something (tecan1) something (tecan2) on the first call it works and does what it is supposed to but on the second call it gets stuck in this loop: Do While Dir <> "" ReDim Preserve aFirstArray(UBound(aFirstArray) + 1) aFirstArray(UBound(aFirstArray)) = Mid(Dir, 1, 4) Loop why does it get stuck in the loop?

    Read the article

  • Operator Overloading for Queue C++

    - by Josh
    I was trying to use the overload operator method to copy the entries of one queue into another, but I am going wrong with my function. I don't know how else to access the values of the queue "original" any other way than what I have below: struct Node { int item; Node* next; }; class Queue { public: [...] //Extra code here void operator = (const Queue &original); protected: Node *front, *end; } void Queue::operator=(const Queue &original) { //THIS IS WHERE IM GOING WRONG while(original.front->next != NULL) { front->item = original.front->item; front->next = new Node; front = front->next; original.front = original.front->next; } }

    Read the article

  • recursively reverse linked list.

    - by Amanda
    I am implementing a function to recursively reverse a linked-list, but getting seg-fault. typedef struct _node { int data; struct _node *next; } Node, *NodeP; NodeP recursiveReverseList(NodeP first){ if(first == NULL) return NULL; if(first->next == NULL) return head; NodeP rest = recursiveReverseList(head->next); rest->next = first; first->next = NULL; return first; } Can you please help. P.S. The iterative version is working fine though. Its not homework. Just practicing C.

    Read the article

  • Linked List. Insert integers in order

    - by user69514
    I have a linked list of integers. When I insert a new Node I need to insert it not at the end, but in oder... i.e. 2, 4, 5, 8, 11, 12, 33, 55, 58, 102, etc. I don't think I am inserting it in the correct position. Do see what Im doing wrong? Node newNode = new Node(someInt); Node current = head; for(int i=0; i<count; i++){ if(current == tail && tail.data < someInt){ tail.next = newNode; } if(current.data < someInt && current.next.data >= someInt){ newNode.next = current.next; current.next = newNode; } }

    Read the article

  • Button INPUT that save datas and link at the same time

    - by user1722384
    Im doing a questionare (form) and i need to put a button submit that do two things : 1) Be a button type INPUT ( because I need to use this kind of button on my php code, I've if(@$_POST['Next']) for save the dates of the form in my DB). 2) That this button will have a link for go to the next screen of the questionare. I tried with a href="demo2.html" target="_blank"><input class="buttonNext" name="submit" type="submit" value="NEXT &#8592" ></a This code don't works but with IE browser on the page page appears a circle next to my button that are the link. So the button don't works, only save the data, but don't link to the next page. How can I solve it ?

    Read the article

  • Segmentation fault in a function to reverse a singly linked list recursivley.

    - by Amanda
    I am implementing a function to recursively reverse a linked-list, but getting seg-fault. typedef struct _node { int data; struct _node *next; } Node, *NodeP; NodeP recursiveReverseList(NodeP first){ if(first == NULL) return NULL; if(first->next == NULL) return first; NodeP rest = recursiveReverseList(first->next); rest->next = first; first->next = NULL; return first; } Can you please help? P.S. The iterative version is working fine though. Its not homework. Just practicing C. Thank you all :)

    Read the article

  • Deploy ASP.NET Web Applications with Web Deployment Projects

    - by Ben Griswold
    One may quickly build and deploy an ASP.NET web application via the Publish option in Visual Studio.  This option works great for most simple deployment scenarios but it won’t always cut it.  Let’s say you need to automate your deployments. Or you have environment-specific configuration settings. Or you need to execute pre/post build operations when you do your builds.  If so, you should consider using Web Deployment Projects. The Web Deployment Project type doesn’t come out-of-the-box with Visual Studio 2008.  You’ll need to Download Visual Studio® 2008 Web Deployment Projects – RTW and install if you want to follow along with this tutorial. I’ve created a shiny new ASP.NET MVC project.  Web Deployment Projects work with websites, web applications and MVC projects so feel free to go with any web project type you’d like.  Once your web application is in place, it’s time to add the Web Deployment project.  You can hunt and peck around the File > New > New Project… dialogue as long as you’d like, but you aren’t going to find what you need.  Instead, select the web project and then choose the “Add Web Deployment Project…” hiding behind the Build menu option. I prefer to name my projects based on the environment in which I plan to deploy.  In this case, I’ll be rolling to the QA machine. Don’t expect too much to happen at this point.  A seemingly empty project with a funny icon will be added to your solution.  That’s it. I want to take a minute and talk about configuration settings before we continue.  Some of the common settings which might change from environment to environment are appSettings, connectionStrings and mailSettings.  Here’s a look at my updated web.config: <appSettings>   <add key="MvcApplication293.Url" value="http://localhost:50596/" />     </appSettings> <connectionStrings>   <add name="ApplicationServices"        connectionString="data source=.\SQLEXPRESS;Integrated Security=SSPI;AttachDBFilename=|DataDirectory|aspnetdb.mdf;User Instance=true"        providerName="System.Data.SqlClient"/> </connectionStrings>   <system.net>   <mailSettings>     <smtp from="[email protected]">         <network host="server.com" userName="username" password="password" port="587" defaultCredentials="false"/>     </smtp>   </mailSettings> </system.net> I want to update these values prior to deploying to the QA environment.  There are variations to this approach, but I like to maintain environment-specific settings for each of the web.config sections in the Config/[Environment] project folders.  I’ve provided a screenshot of the QA environment settings below. It may be obvious what one should include in each of the three files.  Basically, it is a copy of the associated web.config section with updated setting values.  For example, the AppSettings.config file may include a reference to the QA web url, the DB.config would include the QA database server and login information and the StmpSettings.config would include a QA Stmp server and user information. <?xml version="1.0" encoding="utf-8" ?> <appSettings>   <add key="MvcApplication293.Url" value="http://qa.MvcApplicatinon293.com/" /> </appSettings> AppSettings.config  <?xml version="1.0" encoding="utf-8" ?> <connectionStrings>   <add name="ApplicationServices"        connectionString="server=QAServer;integrated security=SSPI;database=MvcApplication293"        providerName="System.Data.SqlClient"/>   </connectionStrings> Db.config  <?xml version="1.0" encoding="utf-8" ?> <smtp from="[email protected]">     <network host="qaserver.com" userName="qausername" password="qapassword" port="587" defaultCredentials="false"/> </smtp> SmtpSettings.config  I think our web project is ready to deploy.  Now, it’s time to concentrate on the Web Deployment Project itself.  Right-click on the project file and open the Property Pages. The first thing to call out is the Configuration dropdown.  I only deploy a project which is built in Release Mode so I only setup the Web Deployment Project for this mode.  (This is when you change the Configuration selection to “Release.”)  I typically keep the Output Folder default value – .\Release\.  When the application is built, all artifacts will be dropped in the .\Release\ folder relative to the Web Deployment Project root.  The final option may be up for some debate.  I like to roll out updatable websites so I select the “Allow this precompiled site to be updatable” option.  I really do like to follow standard SDLC processes when I release my software but there are those times when you just have to make a hotfix to production and I like to keep this option open if need be.  If you are strongly opposed to this idea, please, by all means, don’t check the box. The next tab is boring.  I don’t like to deploy a crazy number of DLLs so I merge all outputs to a single assembly.  Again, you may have another option and feel free to change this selection if you so wish. If you follow my lead, take care when choosing a single assembly name.  The Assembly Name can not be the same as the website or any other project in your solution otherwise you’ll receive a circular reference build error.  In other words, I can’t name the assembly MvcApplication293 or my output window would start yelling at me. Remember when we called out our QA configuration files?  Click on the Deployment tab and you’ll see how where going to use them.  Notice the Web.config file section replacements value.  All this does is swap called out web.config sections with the content of the Config\QA\* files.  You can reduce or extend this list as you deem fit.  Did you see the “Use external configuration source file” option?  You know how you can point any of your web.config sections to an external file via the configSource attribute?  This option allows you to leverage that technique and instead of replacing the content of the sections, you will replace the configSource attribute value instead. <appSettings configSource="Config\QA\AppSettings.config" /> Go ahead and Apply your changes.  I’d like to take a look at the project file we just updated.  Right-click on the Web Deployment Project and select “Open Project File.” One of the first configuration blocks reflects core Release build settings.  There are a couple of points I’d like to call out here: DebugSymbols=false ensures the compilation debug attribute in your web.config is flipped to false as part of build process.  There’s some crumby (more likely old) documentation which implies you need a ToggleDebugCompilation task to make this happen.  Nope. Just make sure the DebugSymbols is set to false.  EnableUpdateable implies a single dll for the web application rather than a dll for each object and and empty view file. I think updatable applications are cleaner and include the benefit (or risk based on your perspective) that portions of the application can be updated directly on the server.  I called this out earlier but I wanted to reiterate. <PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">     <DebugSymbols>false</DebugSymbols>     <OutputPath>.\Release</OutputPath>     <EnableUpdateable>true</EnableUpdateable>     <UseMerge>true</UseMerge>     <SingleAssemblyName>MvcApplication293</SingleAssemblyName>     <DeleteAppCodeCompiledFiles>true</DeleteAppCodeCompiledFiles>     <UseWebConfigReplacement>true</UseWebConfigReplacement>     <ValidateWebConfigReplacement>true</ValidateWebConfigReplacement>     <DeleteAppDataFolder>true</DeleteAppDataFolder>   </PropertyGroup> The next section is self-explanatory.  The content merely reflects the replacement value you provided via the Property Pages. <ItemGroup Condition="'$(Configuration)|$(Platform)' == 'Release|AnyCPU'">     <WebConfigReplacementFiles Include="Config\QA\AppSettings.config">       <Section>appSettings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\Db.config">       <Section>connectionStrings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\SmtpSettings.config">       <Section>system.net/mailSettings/smtp</Section>     </WebConfigReplacementFiles>   </ItemGroup> You’ll want to extend the ItemGroup section to include the files you wish to exclude from the build.  The sample ExcludeFromBuild nodes exclude all obj, svn, csproj, user, pdb artifacts from the build. Enough though they files aren’t included in your web project, you’ll need to exclude them or they’ll show up along with required deployment artifacts.  <ItemGroup Condition="'$(Configuration)|$(Platform)' == 'Release|AnyCPU'">     <WebConfigReplacementFiles Include="Config\QA\AppSettings.config">       <Section>appSettings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\Db.config">       <Section>connectionStrings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\SmtpSettings.config">       <Section>system.net/mailSettings/smtp</Section>     </WebConfigReplacementFiles>     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\obj\**\*.*" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\.svn\**\*.*" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\.svn\**\*" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\*.csproj" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\*.user" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\bin\*.pdb" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\Notes.txt" />   </ItemGroup> Pre/post build and Pre/post merge tasks are added to the final code block.  By default, your project file should look like the following – a completely commented out section. <!– To modify your build process, add your task inside one of        the targets below and uncomment it. Other similar extension        points exist, see Microsoft.WebDeployment.targets.   <Target Name="BeforeBuild">   </Target>   <Target Name="BeforeMerge">   </Target>   <Target Name="AfterMerge">   </Target>   <Target Name="AfterBuild">   </Target>   –> Update the section to remove all temporary Config folders and files after the build.  <!– To modify your build process, add your task inside one of        the targets below and uncomment it. Other similar extension        points exist, see Microsoft.WebDeployment.targets.     <Target Name="BeforeMerge">   </Target>   <Target Name="AfterMerge">   </Target>     <Target Name="BeforeBuild">      </Target>       –>   <Target Name="AfterBuild">     <!– WebConfigReplacement requires the Config files. Remove after build. –>     <RemoveDir Directories="$(OutputPath)\Config" />   </Target> That’s it for setup.  Save the project file, flip the solution to Release Mode and build.  If there’s an issue, consult the Output window for details.  If all went well, you will find your deployment artifacts in your Web Deployment Project folder like so. Both the code source and published application will be there. Inside the Release folder you will find your “published files” and you’ll notice the Config folder is no where to be found.  In the Source folder, all project files are found with the exception of the items which were excluded from the build. I’ll wrap up this tutorial by calling out a little Web Deployment pet peeve of mine: there doesn’t appear to be a way to add an existing web deployment project to a solution.  The best I can come up with is create a new web deployment project and then copy and paste the contents of the existing project file into the new project file.  It’s not a big deal but it bugs me. Download the Solution

    Read the article

  • Introduction to Lean Software Development and Kanban Systems

    - by Ben Griswold
    Last year I took myself through a crash course on Lean Software Development and Kanban Systems in preparation for an in-house presentation.  I learned a bunch.  In this series, I’ll be sharing what I learned with you.   If your career looks anything like mine, you have probably been affiliated with a company or two which pushed requirements gathering and documentation to the nth degree. To add insult to injury, they probably added planning process (documentation, requirements, policies, meetings, committees) to the extent that it possibly retarded any progress. In my opinion, the typical company resembles the quote from Tom DeMarco. It isn’t enough just to do things right – we also had to say in advance exactly what we intended to do and then do exactly that. In the 1980s, Toyota turned the tables and revolutionize the automobile industry with their approach of “Lean Manufacturing.” A massive paradigm shift hit factories throughout the US and Europe. Mass production and scientific management techniques from the early 1900’s were questioned as Japanese manufacturing companies demonstrated that ‘Just-in-Time’ was a better paradigm. The widely adopted Japanese manufacturing concepts came to be known as ‘lean production’. Lean Thinking capitalizes on the intelligence of frontline workers, believing that they are the ones who should determine and continually improve the way they do their jobs. Lean puts main focus on people and communication – if people who produce the software are respected and they communicate efficiently, it is more likely that they will deliver good product and the final customer will be satisfied. In time, the abstractions behind lean production spread to logistics, and from there to the military, to construction, and to the service industry. As it turns out, principles of lean thinking are universal and have been applied successfully across many disciplines. Lean has been adopted by companies including Dell, FedEx, Lens Crafters, LLBean, SW Airlines, Digital River and eBay. Lean thinking got its name from a 1990’s best seller called The Machine That Changed the World : The Story of Lean Production. This book chronicles the movement of automobile manufacturing from craft production to mass production to lean production. Tom and Mary Poppendieck, that is.  Here’s one of their books: Implementing Lean Software Thinking: From Concept to Cash Our in-house presentations are supposed to run no more than 45 minutes.  I really cranked and got through my 87 slides in just under an hour. Of course, I had to cheat a little – I only covered the 7 principles and a single practice. In the next part of the series, we’ll dive into Principle #1: Eliminate Waste. And I am going to be a little obnoxious about listing my Lean and Kanban references with every series post.  The references are great and they deserve this sort of attention. 

    Read the article

  • Throttling in OSB

    - by Knut Vatsendvik
    Technorati Tags: soa,integration,osb,throttling,overload protection A common problem with integration is the risk of overloading a particular web service. When the capacity of a web service is reached and it continues to accept connections, it will most likely start to deteriorate. Fortunately there are 2 techniques, with Oracle Service Bus, that you can apply for protecting this from happening. You can either limit the concurrent number of requests for a Business Service (outbound requests) or you can limit the number of threads processing the requests for a Proxy Service (inbound requests). Limiting the Concurrent Number of Requests Limiting the concurrent requests for a Business Service cannot be set at design time so you have to use the built-in Oracle Service Bus Administration Console to do it (/sbconsole). Follow these steps to enable it: In Change Center, click Create to start a new Session Select Project Explorer, and navigate to the Business Service you want to limit Select the Operational Settings tab of the View a Business Service page In this tab, under Throttling, select the Enable check box. By enabling throttling you Specify a value for Maximum Concurrency Specify a positive integer value for Throttling Queue to backlog messages that has exceeded the message concurrency limit Specify the maximum time in milliseconds for Message Expiration a message can spend in Throttling Queue Click Update Click Active in Change Center to active the new settings If you re-publish the service, it will not overwrite the settings. Only if the resource is renamed or moved, it will. Please note that a throttling queue is an in-memory queue. Messages that are placed in this queue are not recoverable when a server fails or when you restart a server. Limiting the Number of Threads A better approach, in my opinion, is to limit the number of threads that can work with request. Follow these steps to do it: Open the WebLogic Server Console (/console) In Change Center, click Create to start a new Session In the left pane expand Environment and select Work Managers In the Global Work Managers page, click New    Click the Work Manager radio button, then click Next Enter a Name for the new Work Manager, and click Next In the Available Targets list, select server instances or clusters on which you will deploy applications that reference the Work Manager Click Finish. The new Work Manager now appears in the Global Work Managers page. Select the new Work Manager Right next to the Maximum Threads Constraint drop-down box, click New   Click the Maximum Threads Constraint radio button, then click Next Enter a Name and a thread Count to be the maximum size to allocate for requests. Click Next  In the Available Targets list, select server instances or clusters on which you will deploy applications that reference the Work Manager Click Finish Click Save Click Active in Change Center to active your changes.  A restart may be necessary.   Puh! Almost there. Start a new session. Go to the Service Bus Console (/sbconsole) and find your consuming Proxy Service. Click the Edit button of the Transport Configuration tab. Click Next Set the Dispatch Policy to the new Work Manager Click Last Click Save Click Active in Change Center to active your changes. 

    Read the article

  • Overview of Microsoft SQL Server 2008 Upgrade Advisor

    - by Akshay Deep Lamba
    Problem Like most organizations, we are planning to upgrade our database server from SQL Server 2005 to SQL Server 2008. I would like to know is there an easy way to know in advance what kind of issues one may encounter when upgrading to a newer version of SQL Server? One way of doing this is to use the Microsoft SQL Server 2008 Upgrade Advisor to plan for upgrades from SQL Server 2000 or SQL Server 2005. In this tip we will take a look at how one can use the SQL Server 2008 Upgrade Advisor to identify potential issues before the upgrade. Solution SQL Server 2008 Upgrade Advisor is a free tool designed by Microsoft to identify potential issues before upgrading your environment to a newer version of SQL Server. Below are prerequisites which need to be installed before installing the Microsoft SQL Server 2008 Upgrade Advisor. Prerequisites for Microsoft SQL Server 2008 Upgrade Advisor .Net Framework 2.0 or a higher version Windows Installer 4.5 or a higher version Windows Server 2003 SP 1 or a higher version, Windows Server 2008, Windows XP SP2 or a higher version, Windows Vista Download SQL Server 2008 Upgrade Advisor You can download SQL Server 2008 Upgrade Advisor from the following link. Once you have successfully installed Upgrade Advisor follow the below steps to see how you can use this tool to identify potential issues before upgrading your environment. 1. Click Start -> Programs -> Microsoft SQL Server 2008 -> SQL Server 2008 Upgrade Advisor. 2. Click Launch Upgrade Advisor Analysis Wizard as highlighted below to open the wizard. 2. On the wizard welcome screen click Next to continue. 3. In SQL Server Components screen, enter the Server Name and click the Detect button to identify components which need to be analyzed and then click Next to continue with the wizard. 4. In Connection Parameters screen choose Instance Name, Authentication and then click Next to continue with the wizard. 5. In SQL Server Parameters wizard screen select the Databases which you want to analysis, trace files if any and SQL batch files if any.  Then click Next to continue with the wizard. 6. In Reporting Services Parameters screen you can specify the Reporting Server Instance name and then click next to continue with the wizard. 7. In Analysis Services Parameters screen you can specify an Analysis Server Instance name and then click Next to continue with the wizard. 8. In Confirm Upgrade Advisor Settings screen you will be able to see a quick summary of the options which you have selected so far. Click Run to start the analysis. 9. In Upgrade Advisor Progress screen you will be able to see the progress of the analysis. Basically, the upgrade advisor runs predefined rules which will help to identify potential issues that can affect your environment once you upgrade your server from a lower version of SQL Server to SQL Server 2008. 10. In the below snippet you can see that Upgrade Advisor has completed the analysis of SQL Server, Analysis Services and Reporting Services. To see the output click the Launch Report button at the bottom of the wizard screen. 11. In View Report screen you can see a summary of issues which can affect you once you upgrade. To learn more about each issue you can expand the issue and read the detailed description as shown in the below snippet.

    Read the article

  • Slick2D, Nifty GUI listeners problem

    - by Patokun
    I'm trying to get Nifty GUI to work with Slick2D. So far everything is going great, except that I can't seem to figure out how to properly interact with the GUI. I'm trying the example in the nifty manual http://sourceforge.n....0.pdf/download but it doesn't seem to entirely work. The Element controller is being called for bind(...), init(...) and onStartScreen() as it should, as I can see their println output, but the next() method isn't being called when I click on the GUI element that I assigned the controller to, nor the screen controller as no output from println is shown. What's weird is, that the player is moving, so the mouse input is working. It's supposed to be called when I click the mouse button on it from the in the XML. Here is my code: My Element controller: public class ElementController implements Controller { private Element element; @Override public void bind(Nifty nifty, Screen screen, Element element, Properties parameter, Attributes controlDefinitionAttributes) { this.element = element; System.out.println("bind() called for element: " + element); } @Override public void init(Properties parameter, Attributes controlDefinitionAttributes) { System.out.println("init() called for element: " + element); } @Override public void onStartScreen() { System.out.println("onStartScreen() alled for element: " + element); } @Override public void onFocus(boolean getFocus) { System.out.println("onFocus() called for element: " + element + ", with: " + getFocus); } @Override public boolean inputEvent(NiftyInputEvent inputEvent) { return false; } public void next() { System.out.println("next() clicked for element: " + element); } } MyScreenController: class MyScreenController implements ScreenController { public void bind(Nifty nifty, Screen screen) {} public void onEndScreen() {} public void onStartScreen() {} public void next() { System.out.println("next() called from MyScreenController"); } } And my XML file: <?xml version="1.0" encoding="UTF-8"?> <nifty xmlns="http://nifty-gui.sourceforge.net/nifty-1.3.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"xsi:schemaLocation="http://niftygui.sourceforge.net/nifty-1.3.xsd http://nifty-gui.sourceforge.net/nifty-1.3.xsd"> <screen id="start" controller="predaN00b.theThing.V0004.MyScreenController"> <layer childLayout="center" controller="predaN00b.theThing.V0004.ElementController"> <panel width="100px" height="100px" childLayout="vertical" backgroundColor="#ff0f"> <text font="aurulent-sans-16.fnt" color="#ffff" text="Hello World!"> <interact onClick="next()" /> </text> </panel> </layer> </screen> </nifty> My main class, in case it's needed: public class MainGameState extends BasicGame { public Nifty nifty; public MainGame() { super("Test"); } public void init(GameContainer container, StateBasedGame game) throws SlickException { nifty = new Nifty(new SlickRenderDevice(container), new NullSoundDevice(), new PlainSlickInputSystem(), new AccurateTimeProvider()); nifty.addXml("/xml/MainState.xml"); nifty.gotoScreen("start"); } public void update(GameContainer container, StateBasedGame game, int delta) throws SlickException { nifty.update(); } public void render(GameContainer container, StateBasedGame game, Graphics graphics) throws SlickException { nifty.render(false); } public static void main(String[] args) throws SlickException { AppGameContainer app = new AppGameContainer(new MainGame()); app.setAlwaysRender(true); app.setDisplayMode( 1260 , 720, false); //window size app.start(); } }

    Read the article

  • Script to wrap around an application and wait for app to finish

    - by JohnyV
    I need a vb script that will wrap around an applcation which will stay open until the application finishes. I want to be able to call the following command "setup.exe /qb /I Autocad2010.ini /language en-us" But I need the vb script to stay running until the setup has finished. Is there anyone out there that can assist with this. Much appreciated in advance

    Read the article

  • Any reliable polygon normal calculation code?

    - by Jenko
    Do you have any reliable face normal calculation code? I'm using this but it fails when faces are 90 degrees upright or similar. // the normal point var x:Number = 0; var y:Number = 0; var z:Number = 0; // if is a triangle with 3 points if (points.length == 3) { // read vertices of triangle var Ax:Number, Bx:Number, Cx:Number; var Ay:Number, By:Number, Cy:Number; var Az:Number, Bz:Number, Cz:Number; Ax = points[0].x; Bx = points[1].x; Cx = points[2].x; Ay = points[0].y; By = points[1].y; Cy = points[2].y; Az = points[0].z; Bz = points[1].z; Cz = points[2].z; // calculate normal of a triangle x = (By - Ay) * (Cz - Az) - (Bz - Az) * (Cy - Ay); y = (Bz - Az) * (Cx - Ax) - (Bx - Ax) * (Cz - Az); z = (Bx - Ax) * (Cy - Ay) - (By - Ay) * (Cx - Ax); // if is a polygon with 4+ points }else if (points.length > 3){ // calculate normal of a polygon using all points var n:int = points.length; x = 0; y = 0; z = 0 // ensure all points above 0 var minx:Number = 0, miny:Number = 0, minz:Number = 0; for (var p:int = 0, pl:int = points.length; p < pl; p++) { var po:_Point3D = points[p] = points[p].clone(); if (po.x < minx) { minx = po.x; } if (po.y < miny) { miny = po.y; } if (po.z < minz) { minz = po.z; } } if (minx > 0 || miny > 0 || minz > 0){ for (p = 0; p < pl; p++) { po = points[p]; po.x -= minx; po.y -= miny; po.z -= minz; } } var cur:int = 1, prev:int = 0, next:int = 2; for (var i:int = 1; i <= n; i++) { // using Newell method x += points[cur].y * (points[next].z - points[prev].z); y += points[cur].z * (points[next].x - points[prev].x); z += points[cur].x * (points[next].y - points[prev].y); cur = (cur+1) % n; next = (next+1) % n; prev = (prev+1) % n; } } // length of the normal var length:Number = Math.sqrt(x * x + y * y + z * z); // if area is 0 if (length == 0) { return null; }else{ // turn large values into a unit vector x = x / length; y = y / length; z = z / length; }

    Read the article

< Previous Page | 161 162 163 164 165 166 167 168 169 170 171 172  | Next Page >