Search Results

Search found 12264 results on 491 pages for 'drive letter'.

Page 168/491 | < Previous Page | 164 165 166 167 168 169 170 171 172 173 174 175  | Next Page >

  • Creating bootable Fedora USB with persistent storage

    - by dooffas
    I am attempting to burn the full Fedora 19 x86_64 DVD iso to a USB drive and have a separate partition on it for a kickstart file / other media that will be installed in the kickstart process. With the Ubuntu server 12 iso, you can simply dd the iso to the usb drive: dd if=/path/to/iso of=/dev/sdb Once the iso has been burnt, open gparted and create a ext2 parition in the allocated space. However, this does not seem to work with the Fedora ISO. When loading the USB drive in gparted I get a warning and an error: Warning: The driver descriptor says the physical block size is 2048 bytes, but Linux says it is 512 bytes. Error: The partition's data region doesn't occupy the entire partition. Ignoring both of these errors allows gparted to load the usb drive, however it shows a blank drive with no partition table. Has anyone come across this before? From what I have found, it may have something to do with the fact that Fedora use isohybrid.

    Read the article

  • NAS device for distributed team

    - by user5959
    We are a distributed team spread across 5 locations. We have a shared drive (1 TB data) at our former location that we are currently accessing via Hamachi VPN. Our shared drive is a network folder on a Windows Server located at one of our locations. The current connection speed is terrible. The upload speed at the current location of the shared drive is very slow. We looking for a NAS device that we can host at another location with better upload speed that all of us can access. I am looking for a NAS device that has these features: Minimal Maintenance as we do not have dedicated IT resources Access data on the device from multiple locations. Ability to create network drive (On Windows Computers Map Network Drive) Upload data from random client computers without having to install software. (Right now, we use LogMeIn Rescue's file manager) Ability handle slow or dropped connections when transferring files (Maximum size 1.5 GB)

    Read the article

  • Ubuntu 12.4 not listed while in boot menu

    - by radkrish
    I am using Dell Inspiron 17R with Windows7 as the primary OS to boot my system up. I am new to Linux and to begin with, I thought of installing Ubuntu 12.4 AMD 64 bit version on my laptop. Today I performed a successful installation on my laptop but when I reboot, it doesn't show me the Ubuntu OS in the list (I can only see Windows7). Is there any way to bring up the Ubuntu entry into this list? While installing I selected the option to have both Windows7 and Ubuntu OS on my laptop. The root drive for both OS is C: drive. Hence I split the drive into two (250 GB for Windows7 and 250 GB for Ubuntu). Now I can only see 250GB in my C:\ drive for Windows7. Is the remaining 250GB assigned to Ubuntu or did I lose that 250GB space?? Your answers will be highly appreciated..

    Read the article

  • Few questions about backing up the OS

    - by user23950
    I'm running windows 7 with 2gb memory and 2.50 Ghz dual core cpu. here are my question regarding backing up an entire drive. I plan to use Macrium Reflect because its free. And I can't afford to buy one. If I backup a hard drive would I only be able to backup the partition where the operating system is? If I have installed applications which requires activation keys, and I have already installed an activation key. Does backing the hard drive also backup those application, so that I won't have to re-apply the keys later? If I have a multi-boot system, would the backup also include those other OS that are installed in my hard drive? Can I still boot into them after restoring the image? Do you have any links there that could enlighten me on what drive backup really is. Thanks!

    Read the article

  • External hard disk not showing up as removable media

    - by mark
    Windows 7 Pro x64, my external hard drive is a Western Digital Carviar Black. The hard drive is connected via USB (tried all my 2.0 and 3.0 ob my Gigabyte GA-X58A-UD7) but once I initialized it in the "disk management" (or whatever the proper term is; I'm using a German edition of Windows) I have to assign it a manual drive letter. Otherwise it doesn't show up. I'm confused because usually externally connected drives (be it USB sticks or real hard disks) just show up as "Removable media", but this one doesn't. Is this OK/expected? Will there be troubles when I go to another Windows computer? I formatted the drive with quick format and NTFS. I changed the permissions to have read/write for "Everyone" on that drive. thanks

    Read the article

  • External Hard disk not workng on windows after I formatted it on Ubuntu

    - by nav_jan
    I formatted my Western Digital 500 Gb hard disk on Ubuntu 10.4 and now I want to use it on Windows 7 but it cannot detect it. I formatted it with FAT(applicable to all) option. I tried to Google this problem a bit and as suggested by one of the site i tried to format this drive with NTFS. Still windows cannot detect it. Drives in windows 7 is not a problem because I tried a different usb drive on it and it works. I can see the led of the drive glow when I connect it and I can also see remove drive safely option in lower right corner, but i cannot see any option in "my computer" to access the hard disk. I am new to Ubuntu. Any help is appreciated.

    Read the article

  • Troubleshooting failover cluster problem in W2K8 / SQL05

    - by paulland
    I have an active/passive W2K8 (64) cluster pair, running SQL05 Standard. Shared storage is on a HP EVA SAN (FC). I recently expanded the filesystem on the active node for a database, adding a drive designation. The shared storage drives are designated as F:, I:, J:, L: and X:, with SQL filesystems on the first 4 and X: used for a backup destination. Last night, as part of a validation process (the passive node had been offline for maintenance), I moved the SQL instance to the other cluster node. The database in question immediately moved to Suspect status. Review of the system logs showed that the database would not load because the file "K:\SQLDATA\whatever.ndf" could not be found. (Note that we do not have a K: drive designation.) A review of the J: storage drive showed zero contents -- nothing -- this is where "whatever.ndf" should have been. Hmm, I thought. Problem with the server. I'll just move SQL back to the other server and figure out what's wrong.. Still no database. Suspect. Uh-oh. "Whatever.ndf" had gone into the bit bucket. I finally decided to just restore from the backup (which had been taken immediately before the validation test), so nothing was lost but a few hours of sleep. The question: (1) Why did the passive node think the whatever.ndf files were supposed to go to drive "K:", when this drive didn't exist as a resource on the active node? (2) How can I get the cluster nodes "re-syncd" so that failover can be accomplished? I don't know that there wasn't a "K:" drive as a cluster resource at some time in the past, but I do know that this drive did not exist on the original cluster at the time of resource move.

    Read the article

  • Very weird C file-handling anomaly

    - by KáGé
    Hello, I got a very weird issue that I cant figure out in my school project, which is the simulation of a simple filesystem in a human-readable textfile. Unfortunately I don't yet have enough time to translate the comments in my code or make it less gibberish, so if you are bothered by that, you don't have to help, I understand. See the code HERE. Now in drive.h, at line 574 is this part: i = getline(); #ifdef DEBUG printf("Free space in all found at %d.\n\n", i); if(drive.disk != NULL){ printf("Disk OK\n\n"); } #endif //write in data state = seekline(i); Before this it finds place for the allocation database entry in the ALL sector (see the "image files" in the mounts folder, this issue was tested on mount_30.efs-dbf), then gets the line with i = getline() fine (getline is in lglobal.h, line 39), but after that any file manipulation (in this case seekline's fseek, but if I comment that out, then the first fprintf after that) crashes the program straight away. I think the file gets somehow corrupted (though the Disk OK message appears) but can't figure out how. I've tried putting i = getline(); into comment, but it didn't make any difference. I've also tried asking at local programming forums but they didn't really help either. The last few lines of the output before it crashes: Dir written. (drive.h line 562) Seekline entered: 268 (called at drive.h line 564) Getline entered. (called at drive.h line 574) Line got: 268. Free space in all found at 268. (drive.h line 576) Seekline entered: 268 (called at drive.h line 582, note that this exact call was run successfully less than 20 lines back. This one should set the pointer to the beginning of the line it is currently in) After this it crashes. Does anyone has any idea of what causes this and how could I fix it? Thank you.

    Read the article

  • It is said that Mercurial's "hg clone" is very cheap... but it is 400MB on my hard drive? (on Mac OS

    - by Jian Lin
    I have a project I cloned over the network to the Mac hard drive (OS X Snow Leopard). The project is about 1GB in the hard drive du -s 2073848 . so when I hg clone proj proj2 then when I MacBook-Pro ~/development $ du -s proj 2073848 proj MacBook-Pro ~/development $ du -s proj2 894840 proj2 MacBook-Pro ~/development $ du -s 2397928 . so the clone seems not so cheap... probably around 400MB... is that so? also, the whole folder grew by about 200MB, which is not the total of proj and proj2 by the way... are there some links and some are not links, that's why the overlapping is not counted twice?

    Read the article

  • Rebuilding array on 3ware 9690SA-8I

    - by Tim Jones
    I have a RAID10 (8x1TB) array on a 3ware 9690 card running on an Ubuntu 1110 server. There was a kernel update so I scheduled a reboot after which the array was inaccessible. I checked the status a drive has died in the array, but the controller has thrown the entire array into an 'inoperable' state instead of simply degraded (what's the point of the RAID now ;-). After taking out the 'dead' drive I run a quick test to find it completely functional without a bad sector to be found. I try to put the drive back in but the array still marks the disk as degraded (remembering serial number or something??) and the entire array as inoperable... So I swap it out for a known working drive (not the same capacity but higher - should still work) and initiate a rebuild with the the new drive as a replacement. This fails instantly with the error "(0x0B:0x0033): Unit busy : Failed to start Rebuild on Unit 0". The unit shouldn't be busy as it is not mounted (the card itself is listed with lshw but the array it provides is not). I'm pretty much at an impasse now, I don't understand how I can have a single drive failure on a RAID10 that makes the entire array inaccessible, degraded I could understand but inaccessible?? I don't think the controller as prior to the reboot it was completely functional.

    Read the article

  • Problem booting virtual machine after converting VMDK to VHD

    - by vg1890
    I used the VMWare VCenter Converter Standalone Client to convert a physical drive on my old PC to a virtual drive. The conversion worked fine and I ended up with a valid VMDK file. Next, I wanted to convert the VMDK to a VHD for use with Microsoft Virtual PC, since that's what I use on my new box. I used WinImage for the conversion and that worked fine, too. I can access the files from the virtual drive through WinImage. However, when I create a new virtual machine using Virtual PC and add the existing VHD file, the machine doesn't boot. The initial boot screen flashes with the amount of RAM and then the screen goes black. If I turn off the VM and reboot in safe mode I can see the drivers being loaded until eventually it gets to crcdisk.sys and hangs indefinitely. Any ideas how to fix this? I'm not opposed to starting over from scratch if there's another method to turn my physical machine into a Virtual PC VM. Thanks! EDIT - I should add that the virtual drive is a system boot drive and not a secondary drive. EDIT - I tried booting from the install CD and doing a repair. The result was that the system could not be repaired due to a "driver error."

    Read the article

  • Solaris: detect hotswap SATA disk insert

    - by growse
    What's the method used on Solaris to get the system to rescan for new disks that have been hot-plugged on a SATA controller? I've got an HP X1600 NAS which had 9 drives configred in a ZFS pool. I've added 3 disks, but the format command still only shows the original 9. When I plugged them in, I saw this: cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=12 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=11 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=10 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO But can't figure out how to get the format command to see them so I know they've been detected by the system.

    Read the article

  • restoring a failed SBS 2000 box...

    - by Brad Pears
    Hi there, I read a post where you had mentioned you have had a PERC card blow up on you in an SBS box... I've got a similar situation where one of my RAID drives failed and then the power supply failed before I could replace the drive... I then replaced the power supply and the failed drive and reconfigured the RAID array. I had a recent full backup of the my Win2k SBS's C: drive stored on my SYmantec backup exec server so I installed win2K server on the c: partition and then once I had that up and running, installed the backup exec agent so as to do a restore of the entire c drive including system state. THis all worked just fine, until I had to reboot. I received an "incorrect drive configuration" error and then it hangs. I figure that likely makes sense becasue I think my RAID array is configured slightly different now in that the partitions may be sizeded ever so slightly differently now than they were before I think... Is there a way I can just restore from my backup BUT maybe exclude some of the registry and hidden boot files it wants to restore so that it is booting with the current configuration now active on that machine - not the pre blow up configuration files? I also read a post that indicated you might have to install the exact same service pack etc... etc.. before attemting a restore but that does not make sense to me being as the entire c drive contents are going to be overwritten by the restore anyway? THe basic OS install is just to be able to get the backup exec agent installed . I can;t understand why one would need to install the exact same SP level. CAn you shed some light on what I might be able to do to get this thing up and running? Thanks,Brad

    Read the article

  • How can I get my SATA DVDs working again?

    - by user269051
    My hard drive crashed (WinXPpro), so I took a C drive from a broken PC. The new C drive is Win7pro. Motherboard is MSI K8N Neo4 Platinum, with 4 hard drives installed on SATA 1-4 (nForce4 Ultra); the two DVD drives are loaded on SATA 7-8 (Silicon Image SATARAID5). I've tweaked BIOS settings every which way. The closest thing to success was when each DVD had both a CD and a DVD icon, and blinked green. No CD or DVD could be read in either drive. I assume that the problem resulted from the fact that my new C drive does not have the RAID drivers? I've tried loading from the floppy (doesn't work). I can't boot off the DVD/CD, and switching the DVD's SATA cable to the SATA 3 slot (and pulling one of the hard discs) didn't work. I'd like to be able to use the other two available SATA slots for a mirrored RAID drive, and get my DVDs working again. Any suggestions?

    Read the article

  • Why are SMART error rates going down?

    - by Jeff Shattock
    I have a hard drive that's part of a Linux software raid5 array. SMART has reported that its multi_zone_error_rate was 0, then 1, then 3. So I figured I better start backing up more frequently and prepare to replace the drive. Now, today, the multi_zone_error_rate of that very same drive is back down to 1. It seems that 2 errors unhappened while I wasn't looking. I've also seen simliar behaviour by inspecting the syslog on the server. Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 8 02:31:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 These are raw values, not the human-useful values that smartctl -a produces, but the behaviour is similar: error rates changing, then undoing the change. None of these are the drive that had the multi_zone weirdness. I haven't seen any problems from the RAID; its most recent scrub ( < 24 hours ago) came back totally clean. The only thing I can think of is that the SMART reporting circuitry on the drive isn't working properly all the time. The cables are in tight on the drive and board. What's going on here?

    Read the article

  • Best way to attach 96 tb to workstation

    - by user994179
    I'm running a workstation with dual xeon 5690's (12 physical/24 logical cores), 192 gb of ram (ie, maxed-out), Windows 7 64bit, 5 slots for adapter cards, and 1 tb of internal storage, with 5 more internal bays available. I have an app that creates data files totaling about 88 tbs. These are written once every 14 months, and the rest of the time the app only needs to read them; and 95% of the reads are sequential reads of huge chunks of data. I have some control over how big the individual files are, but ideally they would be between 5 and 8 tbs. The app will be reading from only one drive at a time, and the nature of the data is such that if (when) a drive dies I can restore the data to a new disk from tape. While it would be nice to be able to use the fastest drive/controllers available, at this point size matters more than speed. After doing lots of reading, I am leaning toward buying a bunch of cheap 2tb drives and putting them into a bunch of cheap enclosures. All this stuff is going into my home office, so I need to avoid the raised floor/refrigerated approach. My questions: Is the cheap drive/enclosure solution the best one for this situation? Given the nature of the app and the way the data is used, does RAID make sense? If so, which one? For huge sequential reads, would Usb 3.0 and eSata be a wash performance-wise? For each slot available on the workstation, can I hook up an enclosure that can hold multiple drives? Or is it one controller per drive? If I can have multiple drives on one controller, am I essentially splitting the bandwidth (throughput)? For example, if I have a 12 bay enclosure, is the throughput of the controller reduced by a factor of 12? Are there any Windows 7 volume/drive/capacity limits I should be aware of? Thanks

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • How do I fix a super slow MacBook?

    - by MakingScienceFictionFact
    I'm running a black MacBook 4.1. Intel Core 2 Duo @ 2.4 GHz, 2 GB RAM, 250 GB hard disk drive, bus speed is 800 MHz. It's about three years old in excellent shape externally. I treat this thing like a baby. It used to run awesome, but now it's super slow at everything. I get the spinning pizza of death constantly. It takes a long time to boot up or load any program, even Safari and iTunes. iPhoto is terribly slow. The Internet doesn't work properly and it reminds me of a buggy PC. I've formatted it and re-installed Mac OS X 10.6 (with all updates), and I've done the disk repairs process. As an iOS developer this is driving me crazy, but luckily I have an iMac to work on in the day which is fast. I'm ready to format it again, but that didn't work last time. After the last format, I copied back files from an external drive so maybe the offending files were hidden in there somewhere. Here are the hard disk drive and RAM specifications. It is upgrade-able to 4 GB of RAM. Hard disk drive: The Fujitsu Mobile MHY2250BH is a 250 GB, standard hard disk drive. Its burst transfer rate is 150 Mbyte/s. This is a 5400 RPM drive and comes with an 8 MB buffer. RAM: two sticks of 1 GB DDR2 SDRAM, speed: 667 MHz.

    Read the article

  • Cannot delete flash9.ocx

    - by Kara Marfia
    Some kinda voodoo, indeed. Bought a new boot drive, and it's time to use the old drive for data. I thought I'd save some time by just wiping the unneeded system folders, instead of backing up, formatting, and restoring. Wups! I have a single Adobe file that absolutely will not be deleted. G:\Windows\SysWOW64\Macromed\Flash\flash9.ocx - though it may have started with a different file name. I'm able to rename it, oddly enough. To be clear, the drive is currently plugged in externally. So I can boot the computer, plug this drive in afterward, and immediately attempt to delete. "File in use" box reads "the action can't be completed because the file is open in another program". I'd format at this point, but it's my white whale, and I have to know if Adobe has inserted some nasty little registry hack - or whatever it is - making this impossible. Since I'm sure it'll come up, I've taken ownership of the file - and this was the trick preventing me from deleting anything else on the drive - full rights on the file permissions, you name it, I've fiddled with the file itself. I'm about to try uninstalling flash from the system drive, in case that aligns the planets properly. Sometimes I wish I were less stubborn, and could just format already.

    Read the article

  • S.M.A.R.T. broken sectors

    - by Jeffrey Vandenborne
    Recently I received my hard drive (LaCie) that I've sent away for warranty, my disk failed, and I used Palimpsest Disk utility to check if anything was wrong in the S.M.A.R.T Status. And it said that there were a few broken sectors. So the next day, I went to the store and told the story. 4 weeks later I actually got my drive back. The first thing I did was plugging it in and starting the disk utility, and weirdly it showed me pretty much the exact same things, even the values of most tests were the same as they were before when my drive broke. The serial number is different though, but it does show a very peculiar value. Now I'm wondering, I'm almost sure it's the exact same drive and it still says I've got broken sectors, does it just say that because it has been cached in the drive somewhere while LaCie DID actually fix it? Or should I run the extended self test (which seems to take hours) first? Also I've tried the smartctl command tool, it says the drive has smart support, but it doesn't show anything, it says that it's enabled, but then it says that it's disabled, picture below The picture of the Disk utility: Thanks in advance

    Read the article

  • Could hybrid SSD + HDD be made with fixed internal partitions?

    - by Aaron
    I was pretty close to getting Seagate's Momentus XT but have been scared off by the many problems reported on forums and feedback sites, especially in Mac Book Pros. So I'm waiting for mk 2 with some extra flash and better reliablilty I'm assuming will come out this year. What would suit me better though is a 32+500 hybrid drive where I have more control over what is on the flash drive and what is on the disk drive. So there are 2 physical partitions within the one 2.5" hard drive enclosure which use different media internally (32GB for core files and 500GB for data and multimedia). The partitions would be locked so they can't be changed. - Or even better, the disk driver just makes them appear as two disks to the OS that share the same bus... Perhaps it's ok if the bios just sees the first drive until the OS is loaded. Is either of it technically possible? Obviously difficult to market outside of the enthusiast market. The SSD memory modules can be pretty small right, so they could even make them a card that plugs into a secondary connection on the enclosure. That would be good for computer builders as well as for upgrading and recoverability. Then future operating systems could recognise these system SSD drives and automatically install the OS + swap files on it. While placing document libraries on the larger data drive. While in the longer term HDD will probably disapear there will always be a trade off between speed, storage size and expense.

    Read the article

  • Power supply switch like stays off motherboard light turns on

    - by Sion
    I bought a computer at the thrift store yesterday. The computer powered on without any error beeps. Getting it back to the house determined that the CD and hard drive needed to be changed. Put in a populated hard drive to check, the computer turned on and seemed to function. Put in a new CD drive, and just put in a new Hard drive. I plugged it in to check and I noticed that the light for the power supply switch did not come on. But I did notice that the light on the motherboard is lit. and I could not turn the computer on. To help troubleshoot it I unplugged the CD and Hard drive. then re-plugged the power supply and switched it on and off. Nothing changed. Parts: Motherboard: Digital Home PSW DH deluxe Power Supply: FSP-Group FX700-GLN Did I accidentally unplug something while installing the hard drive? Is the Power supply fried somehow?

    Read the article

  • VMWare ESXi 5 - Expanded RAID 5 array - cannot access datastore

    - by Dayton Brown
    I'm using VMWare ESXi 5 and had a 2 TB RAID 5 setup on an HP DL360 with a P400i RAID card. I added two more 1 TB drives and using the SmartStart ACU, added the drives and expanded the logical disk. Now after booting back to ESXi, the server boots, but lists no available persistent storage. I've rescanned multiple times to no avail: the Datastore doesn't show up. I booted to GParted and the 1.8TB partition shows up, but it shows as unknown. Anyone have any good ideas? EDIT: Final Solution So after much gnashing of teeth, it was fairly simple to solve. I purchased an eSata 2 TB external drive and a PCI eSata card for my server. I then used Clonezilla to image the current partitions to my new external drive. You have to check "don't check drive sizes" in advanced mode, otherwise it will yell at you for have a smaller drive. For some reason my PCI card wouldn't boot on my HP server, so I hooked the drive up to another desktop I had, booted to VMWare, and copied the vmdk's to another drive. I'm going to blow out the RAID config and then create 1.5TB logical drives.

    Read the article

  • Recover hard disk from Raw format

    - by user1632736
    I have been all over the web today with no results. So my drive was encrypted (truecrypt) the whole drive where windows resided. I decided to partition it to install W8 and forgot it was encrypted. So the drive got damaged and not accessible. When connected to a computer it asks for formatting. Somehow I enabled the drive through TrueCrypt on another computer and I could see and get all the files. Then I decided to decrypt the drive thinking that everything would be back to normal. After decryption my drive is not NTFS it is in RAW format. I am trying every possible way to recover, and I am desperate enough to ask lol. I tried: ddrescue (linux) (not mountable, no signature, ntfsfix no good) testdisk (linux and windows) Sees the partitions but cant do anything Many recovery applications. etc etc. I read in different places that doing a quickformat to NTFS and then doing a data recovery might help. I would definitely like a second opinion. Any suggestion would be really helpful

    Read the article