Search Results

Search found 17749 results on 710 pages for 'connection pool'.

Page 170/710 | < Previous Page | 166 167 168 169 170 171 172 173 174 175 176 177  | Next Page >

  • Following the Thread in OSB

    - by Antony Reynolds
    Threading in OSB The Scenario I recently led an OSB POC where we needed to get high throughput from an OSB pipeline that had the following logic: 1. Receive Request 2. Send Request to External System 3. If Response has a particular value   3.1 Modify Request   3.2 Resend Request to External System 4. Send Response back to Requestor All looks very straightforward and no nasty wrinkles along the way.  The flow was implemented in OSB as follows (see diagram for more details): Proxy Service to Receive Request and Send Response Request Pipeline   Copies Original Request for use in step 3 Route Node   Sends Request to External System exposed as a Business Service Response Pipeline   Checks Response to Check If Request Needs to Be Resubmitted Modify Request Callout to External System (same Business Service as Route Node) The Proxy and the Business Service were each assigned their own Work Manager, effectively giving each of them their own thread pool. The Surprise Imagine our surprise when, on stressing the system we saw it lock up, with large numbers of blocked threads.  The reason for the lock up is due to some subtleties in the OSB thread model which is the topic of this post.   Basic Thread Model OSB goes to great lengths to avoid holding on to threads.  Lets start by looking at how how OSB deals with a simple request/response routing to a business service in a route node. Most Business Services are implemented by OSB in two parts.  The first part uses the request thread to send the request to the target.  In the diagram this is represented by the thread T1.  After sending the request to the target (the Business Service in our diagram) the request thread is released back to whatever pool it came from.  A multiplexor (muxer) is used to wait for the response.  When the response is received the muxer hands off the response to a new thread that is used to execute the response pipeline, this is represented in the diagram by T2. OSB allows you to assign different Work Managers and hence different thread pools to each Proxy Service and Business Service.  In out example we have the “Proxy Service Work Manager” assigned to the Proxy Service and the “Business Service Work Manager” assigned to the Business Service.  Note that the Business Service Work Manager is only used to assign the thread to process the response, it is never used to process the request. This architecture means that while waiting for a response from a business service there are no threads in use, which makes for better scalability in terms of thread usage. First Wrinkle Note that if the Proxy and the Business Service both use the same Work Manager then there is potential for starvation.  For example: Request Pipeline makes a blocking callout, say to perform a database read. Business Service response tries to allocate a thread from thread pool but all threads are blocked in the database read. New requests arrive and contend with responses arriving for the available threads. Similar problems can occur if the response pipeline blocks for some reason, maybe a database update for example. Solution The solution to this is to make sure that the Proxy and Business Service use different Work Managers so that they do not contend with each other for threads. Do Nothing Route Thread Model So what happens if there is no route node?  In this case OSB just echoes the Request message as a Response message, but what happens to the threads?  OSB still uses a separate thread for the response, but in this case the Work Manager used is the Default Work Manager. So this is really a special case of the Basic Thread Model discussed above, except that the response pipeline will always execute on the Default Work Manager.   Proxy Chaining Thread Model So what happens when the route node is actually calling a Proxy Service rather than a Business Service, does the second Proxy Service use its own Thread or does it re-use the thread of the original Request Pipeline? Well as you can see from the diagram when a route node calls another proxy service then the original Work Manager is used for both request pipelines.  Similarly the response pipeline uses the Work Manager associated with the ultimate Business Service invoked via a Route Node.  This actually fits in with the earlier description I gave about Business Services and by extension Route Nodes they “… uses the request thread to send the request to the target”. Call Out Threading Model So what happens when you make a Service Callout to a Business Service from within a pipeline.  The documentation says that “The pipeline processor will block the thread until the response arrives asynchronously” when using a Service Callout.  What this means is that the target Business Service is called using the pipeline thread but the response is also handled by the pipeline thread.  This implies that the pipeline thread blocks waiting for a response.  It is the handling of this response that behaves in an unexpected way. When a Business Service is called via a Service Callout, the calling thread is suspended after sending the request, but unlike the Route Node case the thread is not released, it waits for the response.  The muxer uses the Business Service Work Manager to allocate a thread to process the response, but in this case processing the response means getting the response and notifying the blocked pipeline thread that the response is available.  The original pipeline thread can then continue to process the response. Second Wrinkle This leads to an unfortunate wrinkle.  If the Business Service is using the same Work Manager as the Pipeline then it is possible for starvation or a deadlock to occur.  The scenario is as follows: Pipeline makes a Callout and the thread is suspended but still allocated Multiple Pipeline instances using the same Work Manager are in this state (common for a system under load) Response comes back but all Work Manager threads are allocated to blocked pipelines. Response cannot be processed and so pipeline threads never unblock – deadlock! Solution The solution to this is to make sure that any Business Services used by a Callout in a pipeline use a different Work Manager to the pipeline itself. The Solution to My Problem Looking back at my original workflow we see that the same Business Service is called twice, once in a Routing Node and once in a Response Pipeline Callout.  This was what was causing my problem because the response pipeline was using the Business Service Work Manager, but the Service Callout wanted to use the same Work Manager to handle the responses and so eventually my Response Pipeline hogged all the available threads so no responses could be processed. The solution was to create a second Business Service pointing to the same location as the original Business Service, the only difference was to assign a different Work Manager to this Business Service.  This ensured that when the Service Callout completed there were always threads available to process the response because the response processing from the Service Callout had its own dedicated Work Manager. Summary Request Pipeline Executes on Proxy Work Manager (WM) Thread so limited by setting of that WM.  If no WM specified then uses WLS default WM. Route Node Request sent using Proxy WM Thread Proxy WM Thread is released before getting response Muxer is used to handle response Muxer hands off response to Business Service (BS) WM Response Pipeline Executes on Routed Business Service WM Thread so limited by setting of that WM.  If no WM specified then uses WLS default WM. No Route Node (Echo functionality) Proxy WM thread released New thread from the default WM used for response pipeline Service Callout Request sent using proxy pipeline thread Proxy thread is suspended (not released) until the response comes back Notification of response handled by BS WM thread so limited by setting of that WM.  If no WM specified then uses WLS default WM. Note this is a very short lived use of the thread After notification by callout BS WM thread that thread is released and execution continues on the original pipeline thread. Route/Callout to Proxy Service Request Pipeline of callee executes on requestor thread Response Pipeline of caller executes on response thread of requested proxy Throttling Request message may be queued if limit reached. Requesting thread is released (route node) or suspended (callout) So what this means is that you may get deadlocks caused by thread starvation if you use the same thread pool for the business service in a route node and the business service in a callout from the response pipeline because the callout will need a notification thread from the same thread pool as the response pipeline.  This was the problem we were having. You get a similar problem if you use the same work manager for the proxy request pipeline and a business service callout from that request pipeline. It also means you may want to have different work managers for the proxy and business service in the route node. Basically you need to think carefully about how threading impacts your proxy services. References Thanks to Jay Kasi, Gerald Nunn and Deb Ayers for helping to explain this to me.  Any errors are my own and not theirs.  Also thanks to my colleagues Milind Pandit and Prasad Bopardikar who travelled this road with me. OSB Thread Model Great Blog Post on Thread Usage in OSB

    Read the article

  • HTTPS Stunnel and Haproxy

    - by panalbish
    I am trying to use stunnel infront of Haproxy for SSL support. SSL certificates are located according to stunnel configuration. I am also able to get the https connection, but every time I use https, session get lost. I am not using tomcat 8443 port to get the secure content. Is is possible to get the https connection only using stunnel and haproxy? And my requirement is to have https connection once user get logged in.

    Read the article

  • Install Oracle Drive and TNS for Windows XP?

    - by David.Chu.ca
    I am building a box with Windows XP with some applications. One application requires connection to an Oracle database on remote. I have installed OracleXEClient.exe from Oracle download. The installation does install "Oracle Provider for OLE DB" driver. My problem is that I still cannot make connections to the remote Oracle db. The test I have done is to create a UDL file with Oracle provider OLE DB connection. The error message is: --------------------------- Microsoft Data Link Error --------------------------- Test connection failed because of an error in initializing provider. ORA-12154: TNS:could not resolve the connect identifier specified I think I may miss TNSNAMEC.ora in the box. I can find this file from another box where Oracle connection works fine. I am not sure what package I should install (from Oracle) so that the default TNSNAEMES.ora will be installed with related files and setup path for accessing the TNS file?

    Read the article

  • email output of powershell script

    - by Gordon Carlisle
    I found this wonderful script that outputs the status of the current DFS backlog to the powershell console. This works great, but I need the script to email me so I can schedule it to run nightly. I have tried using the Send-MailMessage command, but can't get it to work. Mainly because my powershell skills are very weak. I believe most of the issue revolve around the script using the Write-Host command. While the coloring is nice I would much rather have it email me the results. I also need the solution to be able to specify a mail server since the dfs servers don't have email capability. Any help or tips are welcome and appreciated. Here is the code. $RGroups = Get-WmiObject -Namespace "root\MicrosoftDFS" -Query "SELECT * FROM DfsrReplicationGroupConfig" $ComputerName=$env:ComputerName $Succ=0 $Warn=0 $Err=0 foreach ($Group in $RGroups) { $RGFoldersWMIQ = "SELECT * FROM DfsrReplicatedFolderConfig WHERE ReplicationGroupGUID='" + $Group.ReplicationGroupGUID + "'" $RGFolders = Get-WmiObject -Namespace "root\MicrosoftDFS" -Query $RGFoldersWMIQ $RGConnectionsWMIQ = "SELECT * FROM DfsrConnectionConfig WHERE ReplicationGroupGUID='"+ $Group.ReplicationGroupGUID + "'" $RGConnections = Get-WmiObject -Namespace "root\MicrosoftDFS" -Query $RGConnectionsWMIQ foreach ($Connection in $RGConnections) { $ConnectionName = $Connection.PartnerName.Trim() if ($Connection.Enabled -eq $True) { if (((New-Object System.Net.NetworkInformation.ping).send("$ConnectionName")).Status -eq "Success") { foreach ($Folder in $RGFolders) { $RGName = $Group.ReplicationGroupName $RFName = $Folder.ReplicatedFolderName if ($Connection.Inbound -eq $True) { $SendingMember = $ConnectionName $ReceivingMember = $ComputerName $Direction="inbound" } else { $SendingMember = $ComputerName $ReceivingMember = $ConnectionName $Direction="outbound" } $BLCommand = "dfsrdiag Backlog /RGName:'" + $RGName + "' /RFName:'" + $RFName + "' /SendingMember:" + $SendingMember + " /ReceivingMember:" + $ReceivingMember $Backlog = Invoke-Expression -Command $BLCommand $BackLogFilecount = 0 foreach ($item in $Backlog) { if ($item -ilike "*Backlog File count*") { $BacklogFileCount = [int]$Item.Split(":")[1].Trim() } } if ($BacklogFileCount -eq 0) { $Color="white" $Succ=$Succ+1 } elseif ($BacklogFilecount -lt 10) { $Color="yellow" $Warn=$Warn+1 } else { $Color="red" $Err=$Err+1 } Write-Host "$BacklogFileCount files in backlog $SendingMember->$ReceivingMember for $RGName" -fore $Color } # Closing iterate through all folders } # Closing If replies to ping } # Closing If Connection enabled } # Closing iteration through all connections } # Closing iteration through all groups Write-Host "$Succ successful, $Warn warnings and $Err errors from $($Succ+$Warn+$Err) replications." Thanks, Gordon

    Read the article

  • MySQL Federated Tables Escaped Table Names

    - by Gordon
    I am trying to use MySQL federated tables. The problem is that the documentation specified at http://dev.mysql.com/doc/refman/5.0/en/federated-use.html says that a federated table should be created using the following format for the CONNECTION parameter: scheme://user_name[:password]@host_name[:port_num]/db_name/tbl_name E.G. CONNECTION='mysql://username:password@hostname:port/database/tablename' CONNECTION='mysql://username@hostname/database/tablename' CONNECTION='mysql://username:password@hostname/database/tablename' The problem is that the table I am trying to connect to has non-standard characters in it and I cannot find the proper way to scape them in the connections tring. For example, a table named `Table (one)` . Which has the space and the parenthesis, requiring backticks surrounding it inside any SQL code. Anyone know the proper way to do this?

    Read the article

  • Static objects and concurrency in a web application

    - by Ionut
    I'm developing small Java Web Applications on Tomcat server and I'm using MySQL as my database. Up until now I was using a connection singleton for accessing the database but I found out that this will ensure just on connection per Application and there will be problems if multiple users want to access the database in the same time. (They all have to make us of that single Connection object). I created a Connection Pool and I hope that this is the correct way of doing things. Furthermore it seems that I developed the bad habit of creating a lot of static object and static methods (mainly because I was under the wrong impression that every static object will be duplicated for every client which accesses my application). Because of this all the Service Classes ( classes used to handle database data) are static and distributed through a ServiceFactory: public class ServiceFactory { private static final String JDBC = "JDBC"; private static String impl; private static AccountService accountService; private static BoardService boardService; public static AccountService getAccountService(){ initConfig(); if (accountService == null){ if (impl.equalsIgnoreCase(JDBC)){ accountService = new JDBCAccountService(); } } return accountService; } public static BoardService getBoardService(){ initConfig(); if (boardService == null){ if (impl.equalsIgnoreCase(JDBC)){ boardService = new JDBCBoardService(); } } return boardService; } private static void initConfig(){ if (StringUtil.isEmpty(impl)){ impl = ConfigUtil.getProperty("service.implementation"); // If the config failed initialize with standard if (StringUtil.isEmpty(impl)){ impl = JDBC; } } } This was the factory class which, as you can see, allows just one Service to exist at any time. Now, is this a bad practice? What happens if let's say 1k users access AccountService simultaneously? I know that all this questions and bad practices come from a bad understanding of the static attribute in a web application and the way the server handles this attributes. Any help on this topic would be more than welcomed. Thank you for your time!

    Read the article

  • QoS - split bandwidth across all IPs during high load

    - by Matthew Iselin
    We have a Linux-based router which is currently working fairly well, but our network only has a 1.5 mbps incoming connection. The network is small, but during high load periods some systems can end up dominating the bandwidth. For example, a client downloading a file can easily saturate the connection leaving everyone else with barely any access to the outside world. Naturally, I'd like to fix this. I believe a combination of iptables rules and tc is in order, but I have no idea how to go about distributing the bandwidth evenly across the clients. It would be nice if there was a way to divide the bandwidth only across clients that are actually utilising the connection as well, rather than hard limit each connection to (bandwidth / number of clients).

    Read the article

  • proftpd, dynamic IP, and filezilla: port troubles

    - by Yami
    The basic setup: Two computers, one running proftpd, one attempting to connect via filezilla. Both linux (xubuntu on the server, kubuntu on the client). Both are at the moment behind a router on a residential (read: dynamic IP) connection; the client is a laptop I plan to take away from the home network, so I'll need this to work externally. I have my router set up to allow specific ports forwarded to each machine and, where possible, have plugged in those numbers into proftpd (via gadmin, double-checking the config file) and filezilla. Attempting to connect via active mode using the internal IP works: Status: Connecting to 192.168.1.139:8085... Status: Connection established, waiting for welcome message... Response: 220 Crossroads FTP Command: USER <redacted> Response: 331 Password required for <redacted> Command: PASS ******* Response: 230 Anonymous access granted, restrictions apply Command: OPTS UTF8 ON Response: 200 UTF8 set to on Status: Connected Status: Retrieving directory listing... Command: PWD Response: 257 "/" is the current directory Command: TYPE I Response: 200 Type set to I Command: PORT 192,168,1,52,153,140 Response: 200 PORT command successful Command: LIST Response: 150 Opening ASCII mode data connection for file list Response: 226 Transfer complete Status: Directory listing successful Attempting to connect via the domain name, however, leads to issues; in active mode, the PORT is the last command to be received according to the server's logs, and in passive mode, it's the PASV command. This leads me to believe I'm being redirected to a bad port? Active Sample: Status: Resolving address of <url> Status: Connecting to <ip:port> Status: Connection established, waiting for welcome message... Response: 220 Crossroads FTP Command: USER <redacted> Response: 331 Password required for <redacted> Command: PASS ******* Response: 230 Anonymous access granted, restrictions apply Command: OPTS UTF8 ON Response: 200 UTF8 set to on Status: Connected Status: Retrieving directory listing... Command: PWD Response: 257 "/" is the current directory Command: TYPE I Response: 200 Type set to I Command: PORT 174,111,127,27,153,139 Response: 200 PORT command successful Command: LIST Error: Connection timed out Error: Failed to retrieve directory listing Passive sample: Status: Resolving address of ftp.bonsaiwebdesigns.com Status: Connecting to 174.111.127.27:8085... Status: Connection established, waiting for welcome message... Response: 220 Crossroads FTP Command: USER yamikuronue Response: 331 Password required for yamikuronue Command: PASS ******* Response: 230 Anonymous access granted, restrictions apply Command: OPTS UTF8 ON Response: 200 UTF8 set to on Status: Connected Status: Retrieving directory listing... Command: PWD Response: 257 "/" is the current directory Command: TYPE I Response: 200 Type set to I Command: PASV Response: 227 Entering Passive Mode (64,95,64,197,101,88). Command: LIST Error: Connection timed out Error: Failed to retrieve directory listing In both cases, the log file ends at "PORT" or "PASV" - there's no record of ever receiving a "LIST" command. Just above that I can see the attempt to connect actively via the internal IP, which does indeed include a LIST command. My config file includes "PassivePorts 20001-26999", which are the port forwards I set up for the ftp server, and "Port 8085", which is also forwarded to the same machine. I also have a MasqueradeAddress set up to prevent it from reporting its internal IP, which was an earlier issue I had. I think what I'm asking is, is there another setting someplace I have to change to get this setup to work?

    Read the article

  • Performance problem with an Intel Wireless 5100

    - by Piet
    I just installed 12.04 on a HP Elitebook 2530p. The performance with wireless connection to an Eminem 4551 is very bad. Wired connection just works great. If I connect to my router (Eminent 4551) wired I have a good performance accessing internet pages with Firefox. When I try to access the same internet pages wireless I get a real bad performance. piet@piet-HP-EliteBook-2530p:~$ lspci 00:00.0 Host bridge: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub (rev 07) 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:03.0 Communication controller: Intel Corporation Mobile 4 Series Chipset MEI Controller (rev 07) 00:03.2 IDE interface: Intel Corporation Mobile 4 Series Chipset PT IDER Controller (rev 07) 00:03.3 Serial controller: Intel Corporation Mobile 4 Series Chipset AMT SOL Redirection (rev 07) 00:19.0 Ethernet controller: Intel Corporation 82567LM Gigabit Network Connection (rev 03) 00:1a.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 03) 00:1a.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 03) 00:1a.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 03) 00:1a.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 03) 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) 00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 03) 00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 03) 00:1c.2 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 3 (rev 03) 00:1d.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 03) 00:1d.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 03) 00:1d.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 03) 00:1d.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 03) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 93) 00:1f.0 ISA bridge: Intel Corporation ICH9M-E LPC Interface Controller (rev 03) 00:1f.2 SATA controller: Intel Corporation 82801IBM/IEM (ICH9M/ICH9M-E) 4 port SATA Controller [AHCI mode] (rev 03) 02:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection 44:06.0 FireWire (IEEE 1394): Ricoh Co Ltd R5C832 IEEE 1394 Controller (rev 05) 44:06.1 SD Host controller: Ricoh Co Ltd R5C822 SD/SDIO/MMC/MS/MSPro Host Adapter (rev 22) piet@piet-HP-EliteBook-2530p:~$

    Read the article

  • Change sysout logging level for Weblogic

    - by Justin Voss
    When I run a local copy of Weblogic, I like to see the output in the console so that I can observe my app's logging messages. But, Weblogic spits out a lot of log messages I don't care about, like these: [ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)' 08-29-2010 01:02:21 INFO Getting a JNDI connection [ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)' 08-29-2010 01:02:21 INFO Connection Returned. Elapsed time to acquire=0ms. [ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)' 08-29-2010 01:02:21 INFO Getting a JNDI connection [ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)' 08-29-2010 01:02:21 INFO Connection Returned. Elapsed time to acquire=0ms. Can I configure Weblogic to not output those? I assume that I can change the logging level to something higher than INFO and that should fix it?

    Read the article

  • FairScheduling Conventions in Hadoop

    - by dan.mcclary
    While scheduling and resource allocation control has been present in Hadoop since 0.20, a lot of people haven't discovered or utilized it in their initial investigations of the Hadoop ecosystem. We could chalk this up to many things: Organizations are still determining what their dataflow and analysis workloads will comprise Small deployments under tests aren't likely to show the signs of strains that would send someone looking for resource allocation options The default scheduling options -- the FairScheduler and the CapacityScheduler -- are not placed in the most prominent position within the Hadoop documentation. However, for production deployments, it's wise to start with at least the foundations of scheduling in place so that you can tune the cluster as workloads emerge. To do that, we have to ask ourselves something about what the off-the-rack scheduling options are. We have some choices: The FairScheduler, which will work to ensure resource allocations are enforced on a per-job basis. The CapacityScheduler, which will ensure resource allocations are enforced on a per-queue basis. Writing your own implementation of the abstract class org.apache.hadoop.mapred.job.TaskScheduler is an option, but usually overkill. If you're going to have several concurrent users and leverage the more interactive aspects of the Hadoop environment (e.g. Pig and Hive scripting), the FairScheduler is definitely the way to go. In particular, we can do user-specific pools so that default users get their fair share, and specific users are given the resources their workloads require. To enable fair scheduling, we're going to need to do a couple of things. First, we need to tell the JobTracker that we want to use scheduling and where we're going to be defining our allocations. We do this by adding the following to the mapred-site.xml file in HADOOP_HOME/conf: <property> <name>mapred.jobtracker.taskScheduler</name> <value>org.apache.hadoop.mapred.FairScheduler</value> </property> <property> <name>mapred.fairscheduler.allocation.file</name> <value>/path/to/allocations.xml</value> </property> <property> <name>mapred.fairscheduler.poolnameproperty</name> <value>pool.name</value> </property> <property> <name>pool.name</name> <value>${user.name}</name> </property> What we've done here is simply tell the JobTracker that we'd like to task scheduling to use the FairScheduler class rather than a single FIFO queue. Moreover, we're going to be defining our resource pools and allocations in a file called allocations.xml For reference, the allocation file is read every 15s or so, which allows for tuning allocations without having to take down the JobTracker. Our allocation file is now going to look a little like this <?xml version="1.0"?> <allocations> <pool name="dan"> <minMaps>5</minMaps> <minReduces>5</minReduces> <maxMaps>25</maxMaps> <maxReduces>25</maxReduces> <minSharePreemptionTimeout>300</minSharePreemptionTimeout> </pool> <mapreduce.job.user.name="dan"> <maxRunningJobs>6</maxRunningJobs> </user> <userMaxJobsDefault>3</userMaxJobsDefault> <fairSharePreemptionTimeout>600</fairSharePreemptionTimeout> </allocations> In this case, I've explicitly set my username to have upper and lower bounds on the maps and reduces, and allotted myself double the number of running jobs. Now, if I run hive or pig jobs from either the console or via the Hue web interface, I'll be treated "fairly" by the JobTracker. There's a lot more tweaking that can be done to the allocations file, so it's best to dig down into the description and start trying out allocations that might fit your workload.

    Read the article

  • Networking 2 Virtual PC with one VPC as DHCP server

    - by vivek
    My host OS is Win XP Professional. The host has a real network connection via DSL and I created a second network connection using Microsoft Loopback Adapter. Internet connection sharing is enabled. The Microsoft Loopback adapter has a IP address of 192.168.0.1. I have 1 Virtual PC which has Windows Server 2003. I have setup the network connection on this VPC to use Microsoft Loopback Adapter. I setup this VPC to be the Domain Controller , DNS Server and DHCP Server. I set this to a static IP address 192.168.0.2 (on the same subnet as the MS Loopback adapter) I have a second Virtual PC which also has Windows Server 2003. The network connection on this VPC is set to "Local Only". I want this VPC to get its IP address from the 1st VPC on which I setup as a DHCP server. What i want is the 2 VPC should be in a network with one of the VPC acting as the domain controller, DNS Server and DHCP server. The second VPC shoud get its IP address from the 1st VPC. It should be a part of the domain of the 1st VPC. When i tried to make the second VPC get the IP address from the first VPC I am not succeeding. Can somebody post some suggestions on how to go about this ?

    Read the article

  • GRE Tunnel over IPsec with Loopback

    - by Alek
    I'm having a really hard time trying to estabilish a VPN connection using a GRE over IPsec tunnel. The problem is that it involves some sort of "loopback" connection which I don't understand -- let alone be able to configure --, and the only help I could find is related to configuring Cisco routers. My network is composed of a router and a single host running Debian Linux. My task is to create a GRE tunnel over an IPsec infrastructure, which is particularly intended to route multicast traffic between my network, which I am allowed to configure, and a remote network, for which I only bear a form containing some setup information (IP addresses and phase information for IPsec). For now it suffices to estabilish a communication between this single host and the remote network, but in the future it will be desirable for the traffic to be routed to other machines on my network. As I said this GRE tunnel involves a "loopback" connection which I have no idea of how to configure. From my previous understanding, a loopback connection is simply a local pseudo-device used mostly for testing purposes, but in this context it might be something more specific that I do not have the knowledge of. I have managed to properly estabilish the IPsec communication using racoon and ipsec-tools, and I believe I'm familiar with the creation of tunnels and addition of addresses to interfaces using ip, so the focus is on the GRE step. The worst part is that the remote peers do not respond to ping requests and the debugging of the general setup is very difficult due to the encrypted nature of the traffic. There are two pairs of IP addresses involved: one pair for the GRE tunnel peer-to-peer connection and one pair for the "loopback" part. There is also an IP range involved, which is supposed to be the final IP addresses for the hosts inside the VPN. My question is: how (or if) can this setup be done? Do I need some special software or another daemon, or does the Linux kernel handle every aspect of the GRE/IPsec tunneling? Please inform me if any extra information could be useful. Any help is greatly appreciated.

    Read the article

  • Jboss unreachable/ slow behind apache with ajp

    - by Niels
    I have an linux server running with a JBoss Instance with apache2. Apache2 will use AJP connection to reverse proxy to JBoss. I found these messages in the apache error.log: [error] (70007)The timeout specified has expired: ajp_ilink_receive() can't receive header [error] ajp_read_header: ajp_ilink_receive failed [error] (120006)APR does not understand this error code: proxy: read response failed from 8.8.8.8:8009 (hostname) [error] (111)Connection refused: proxy: AJP: attempt to connect to 8.8.8.8:8009 (hostname) failed [error] ap_proxy_connect_backend disabling worker for (hostname) [error] proxy: AJP: failed to make connection to backend: hostname [error] proxy: AJP: disabled connection for (hostname)25 I googled around but I can't seem to find any related topics. There are people say this behavior can be caused by misconfigured apache vs jboss. Telling the max amount of connections apache allows are far greater then jboss, causing the apache connection to time out. But I know the app isn't used by thousands of simultaneous connections at the time not even hundreds of connections so I don't believe this could be a cause. Does anybody have an idea? Or could tell me how to debug this problem? I'm using these versions: Debian 4.3.5-4 64Bit Apache Version 2.2.16 JBOSS Version 4.2.3.GA Thanks

    Read the article

  • If Nvidia Shield can stream a game via WiFi (~150-300Mbps), where is the 1-10Gbps wired streaming?

    - by Enigma
    Facts: It is surprising and uncharacteristic that a wireless game streaming solution is the *first to hit the market when a 1000mbps+ Ethernet connection would accomplish the same feat with roughly 6x the available bandwidth. 150-300mbps WiFi is in no way superior to a 1000mbps+ LAN connection aside from well wireless mobility. Throughout time, (since the internet was created) wired services have **always come first yet in this particular case, the opposite seems to be true. We had wired internet first, wired audio streaming, and wired video streaming all before their wireless counterparts. Why? Largely because the wireless bandwidth was and is inferior. Even today despite being significantly better and capable of a lot more, it is still inferior to a wired connection. Situation: Chief among these is that NVIDIA’s Shield handheld game console will be getting a microconsole-like mode, dubbed “Shield Console Mode”, that will allow the handheld to be converted into a more traditional TV-connected console. In console mode Shield can be controlled with a Bluetooth controller, and in accordance with the higher resolution of TVs will accept 1080p game streaming from a suitably equipped PC, versus 720p in handheld mode. With that said 1080p streaming will require additional bandwidth, and while 720p can be done over WiFi NVIDIA will be requiring a hardline GigE connection for 1080p streaming (note that Shield doesn’t have Ethernet, so this is presumably being done over USB). Streaming aside, in console mode Shield will also support its traditional local gaming/application functionality. - http://www.anandtech.com/show/7435/nvidia-consolidates-game-streaming-tech-under-gamestream-brand-announces-shield-console-mode ^ This is not acceptable to me for a number of reasons not to mention the ridiculousness of having a little screen+controller unit sitting there while using a secondary controller and screen instead. That kind of redundant absurdity exemplifies how wrong of a solution that is. They need a second product for this solution without the screen or controller for it to make sense... at which point your just buying a little computer that does what most other larger computers do better. While this secondary project will provide a wired connection, it still shouldn't be necessary to purchase a Shield to have this benefit. Not only this but Intel's WiDi claims game streaming support as well - wirelessly. Where is the wired streaming? All that is required, by my understanding, is the ability to decode H.264 video compression and transmit control/feedback so by any logical comparison, one (Nvidia especially) should have no difficulty in creating an application for PC's (win32/64 environment) that does the exact same thing their android app does. I have 2 video cards capable of streaming (encoding) H.264 so by right they must be capable of decoding it I would think. I should be able to stream to my second desktop or my laptop both of which by hardware comparison are superior to the Shield. I haven't found anything stating plans to allow non-shield owners to do this. Can a third party create this software or does it hinge on some limitation that only Nvidia can overcome? Reiteration of questions: Is there a technical reason (non marketing) for why Nvidia opted to bottleneck the streaming service with a wireless connection limiting the resolution to 720p and introducing intermittent video choppiness when on a wired connection one could achieve, presumably, 1080p with significantly less or zero choppiness? Is there anything limiting developers from creating a PC/Desktop application emulating the same H.264 decoding functionality that circumvents the need to get an Nvidia Shield altogether? (It is not a matter of being too cheap to support Nvidia - I have many Nvidia cards that aren't being used. One should not have to purchase specialty hardware when = hardware already exists) Same questions go for Intel Widi also. I am just utterly perplexed that there are wireless live streaming solution and yet no wired. How on earth can wireless be the goto transmission medium? Is there another solution that takes advantage of H.264 video compression allowing live streaming over a wired connection? (*) - Perhaps this isn't the first but afaik it is the first complete package. (**) - I cant back that up with hard evidence/links but someone probably could. Edit: Maybe this will be the solution I am looking for but I still find it hard to believe that they would be the first and after wireless solutions already exist. In-home Streaming You can play all your Windows and Mac games on your SteamOS machine, too. Just turn on your existing computer and run Steam as you always have - then your SteamOS machine can stream those games over your home network straight to your TV! - http://store.steampowered.com/livingroom/SteamOS/

    Read the article

  • MySQL – Beginning Temporary Tables in MySQL

    - by Pinal Dave
    MySQL supports Temporary tables to store the resultsets temporarily for a given connection. Temporary tables are created with the keyword TEMPORARY along with the CREATE TABLE statement. Let us create the temporary table named Temp CREATE TEMPORARY TABLE TEMP (id INT); Now you can find out the column names using DESC command DESC TEMP; The above returns the following result This table can be accessed only for the current connection and it can be used like a permanent table and automatically dropped when the connection is closed. However, you can not find temporary tables using INFORMATION_SCHEMA. TABLES system view. It will only list out the permanent tables. MySQL usually stores the data of temporary tables in memory and processed by Memory Storage engine. But if the data size is too large MySQL automatically converts this to the on – disk table and use MyISAM engine. You can also create a permanent table with the same name of a temporary table in the same connection. However the structure of permanent table is visible only if the temporary table with the same name is dropped. Let us create a permanent table with the same name Temp as below CREATE TABLE TEMP (id INT, names VARCHAR(100)); Now running the following command stills gives you the structure of the temporary table temp created earlier. DESC TEMP; You can drop the temporary table using DROP TEMPORARY TABLE command; DROP TEMPORARY TABLE TEMP; After you executed the temporary table, run the following command DESC TEMP; Now you will see the structure of the permanent table named temp In summary – If there is a Temporary Table in MySQL it gets first priority over the permanent table in the session. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: MySQL, PostADay, SQL, SQL Authority, SQL Query, SQL Tips and Tricks, T SQL

    Read the article

  • New CAT5 cable run is unstable - bad jacks? Bad cable?

    - by BeemerGuy
    This is a little project I'm doing at home. I wanted to wire two rooms together (basically, the router is one room, and the switch is in the second room). So I ran a CAT5 between the two rooms, and wired an RJ45 jack in each room. I then hooked up the two jacks with two CAT5 cable to run it through the cable tester, and all 8 wires seem good. Now, when I connect the switch and the router, the connection is unstable -- I ping the router and it barely holds on for two pings before it disconnects, and stays in that unstable state. Just to make sure the router and the switch are ok, I connected them with long wire between the two rooms and the connection is absolutely stable, and pings continuously. What could be the cause for the unstable connection? Especially that it pings a few times, so there IS a connection. But why is it unstable? And how come the cable tester says it's ok, but it's unstable?

    Read the article

  • Why would you ever set MaxKeepAliveRequests to anything but unlimited?

    - by Jonathon Reinhart
    Apache's KeepAliveTimeout exists to close a keep-alive connection if a new request is not issued within a given period of time. Provided the user does not close his browser/tab, this timeout (usually 5-15 seconds) is what eventually closes most keep-alive connections, and prevents server resources from being wasted by holding on to connections indefinitely. Now the MaxKeepAliveRequests directive puts a limit on the number of HTTP requests that a single TCP connection (left open due to KeepAlive) will serve. Setting this to 0 means an unlimited number of requests are allowed. Why would you ever set this to anything but "unlimited"? Provided a client is still actively making requests, what harm is there in letting them happen on the same keep-alive connection? Once the limit is reached, the requests still come in, just on a new connection. The way I see it, there is no point in ever limiting this. What am I missing?

    Read the article

  • Show table gives - ERROR 2002 (HY000): Can't connect to local MySQL server through socket

    - by arn
    I am having the InnodB tables and show tables gives following error ? mysql (mydb) > show tables; ERROR 2006 (HY000): MySQL server has gone away No connection. Trying to reconnect... Connection id: 1 Current database: mydb ERROR 2006 (HY000): MySQL server has gone away No connection. Trying to reconnect... ERROR 2002 (HY000): Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock1' (111) ERROR: Can't connect to the server

    Read the article

  • How to debug solve 500 Internal error aws micro ec2 with suexec, Apache and php CGi

    - by Oudin
    I'm running WordPress multi-site on an amazon micro ec2 with suexec, Apache and php CGi On Ubuntu 12.04 However I've been experiencing a lot of Internal server 500 errors and I'm in the process of debugging it to find a solution. I've posted my error logs below example.com error.log: [Fri Oct 26 10:10:08 2012] [warn] [client 23.23.xxx.xx] (104)Connection reset by peer: mod_fcgid: error reading data from FastCGI server [Fri Oct 26 10:10:08 2012] [error] [client 23.23.xxx.xx] Premature end of script headers: wp-cron.php [Fri Oct 26 10:50:04 2012] [warn] [client 190.213.xxx.xxx] (104)Connection reset by peer: mod_fcgid: error reading data from FastCGI server, referer: https://www.example.com/wp-admin/ [Fri Oct 26 10:50:04 2012] [error] [client 190.213.xxx.xxx] Premature end of script headers: admin.php, referer: https://www.example.com/wp-admin/ [Fri Oct 26 10:58:14 2012] [warn] [client 190.213.xxx.xxx] (104)Connection reset by peer: mod_fcgid: error reading data from FastCGI server, referer: https://www.example.com/wp-admin/network/index.php [Fri Oct 26 10:58:15 2012] [error] [client 190.213.xxx.xxx] Premature end of script headers: admin-ajax.php, referer: https://www.example.com/wp-admin/network/index.php [Fri Oct 26 10:58:56 2012] [warn] [client 190.213.xxx.xxx] (104)Connection reset by peer: mod_fcgid: error reading data from FastCGI server, referer: https://www.example.com/wp-admin/network/index.php [Fri Oct 26 10:58:57 2012] [error] [client 190.213.xxx.xxx] Premature end of script headers: plugins.php, referer: https://www.example.com/wp-admin/network/index.php [Fri Oct 26 10:59:18 2012] [warn] [client 190.213.xxx.xxx] (104)Connection reset by peer: mod_fcgid: error reading data from FastCGI server, referer: https://www.example.com/wp-admin/network/index.php [Fri Oct 26 10:59:18 2012] [error] [client 190.213.xxx.xxx] Premature end of script headers: admin-ajax.php, referer: https://www.example.com/wp-admin/network/index.php [Fri Oct 26 11:01:49 2012] [warn] [client 190.213.xxx.xxx] (104)Connection reset by peer: mod_fcgid: error reading data from FastCGI server, referer: https://www.example.com/wp-admin/ [Fri Oct 26 11:01:49 2012] [warn] [client 190.213.xxx.xxx] (104)Connection reset by peer: mod_fcgid: ap_pass_brigade failed in handle_request_ipc function, referer: https://www.example.com/wp-admin/ Apache Log: php (pre-forking): Cannot allocate memory php (pre-forking): Cannot allocate memory Recipient names must be specified Recipient names must be specified php (pre-forking): Cannot allocate memory php (pre-forking): Cannot allocate memory php (pre-forking): Cannot allocate memory [Fri Oct 26 10:49:33 2012] [warn] mod_fcgid: cleanup zombie process 2852 [Fri Oct 26 10:49:33 2012] [warn] mod_fcgid: cleanup zombie process 2851 [Fri Oct 26 10:49:33 2012] [warn] mod_fcgid: cleanup zombie process 2853 [Fri Oct 26 10:58:22 2012] [warn] mod_fcgid: process 2892 graceful kill fail, sending SIGKILL php (pre-forking): Cannot allocate memory [Fri Oct 26 10:59:21 2012] [warn] mod_fcgid: process 2894 graceful kill fail, sending SIGKILL [Fri Oct 26 10:59:25 2012] [warn] mod_fcgid: process 2866 graceful kill fail, sending SIGKILL suexec.log: [2012-10-25 16:05:36]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 18:09:38]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 18:09:51]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 18:14:03]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 18:14:06]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 18:14:35]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 20:20:27]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 20:20:29]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 20:20:31]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 21:42:12]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-25 22:56:50]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 02:34:43]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 04:25:07]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 06:35:19]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 06:40:05]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 07:22:45]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 10:10:05]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 10:49:24]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi [2012-10-26 10:49:24]: uid: (1002/username) gid: (1002/username) cmd: php-fcgi based on the logs can any determine what might be the cause of this? Thinking that it might be the micro instance I'm thinking of upgrading to a small. Any help would be greatly appreciated.

    Read the article

  • Windows Storage Server 2003 R2 RDP Disconnection

    - by Antitribu
    I am unable to remote desktop to our Windows Storage Server 2003 R2 machine. There are a few people about with similar issues but no answers around. Symantec End Point is installed but no network protection. Using rdesktop in Linux I receive: ERROR: send: Connection reset by peer NOT IMPLEMENTED: PDU 12 ERROR: Connection closed Where the "PDU XX" number changes on each connection. In windows using the latest mstsc I receive: The connection was lost due to a network error. Try connecting again. If the problem persists, contact your network Administrator. Any ideas?

    Read the article

  • Why do I have 55 local area connections in ipconfig?

    - by RMorrisey
    Windows Vista Home Premium. I should mention that I am having no problem whatever getting an internet connection. When I type "ipconfig" in the console, I get (55!) messages of 3 lines each, listing a ton of disconnected network connections. My PC only has one network card. Each message looks like this: Tunnel adapter Local Area Connection* 55: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : These don't cause a major problem; they make it a pain, though, to fish upward and find my IP address. How can I get rid of them? Edit: Actually, a few connection numbers are randomly missing from the sequence; so, it's really more like 30 or 40 connection messages, rather than all 55. Not sure why that is, either.

    Read the article

  • php file downloads instead of being processed with ajax on apache

    - by eagleon
    I have a small website where some content is displayed within a HTML tag using AJAX. The content is simply taken from another page on the same web site. However, sometimes instead of loading the parsed PHP file, the browser displays a download box instead. I downloaded the file and this is what it looks like a text file mixed with binary or gzipped data. I can't paste the binary stuff here, but here are some of the headers: Jul 2012 18:52:16 GMT Server: Apache/2 X-Powered-By: PHP/5.3.10 Content-Encoding: gzip Vary: Accept-Encoding,User-Agent Keep-Alive: timeout=1, max=95 Connection: Keep-Alive Transfer-Encoding: chunked Content-Type: text/html HTTP/1.1 304 Not Modified Date: Sun, 01 Jul 2012 18:52:16 GMT Server: Apache/2 Connection: Keep-Alive Keep-Alive: timeout=1, max=93 ETag: "2fc857-409-4c39691c59b40" HTTP/1.1 304 Not Modified Date: Sun, 01 Jul 2012 18:52:16 GMT Server: Apache/2 Connection: Keep-Alive Keep-Alive: timeout=1, max=92 ETag: "2fc854-3e5-4c39691b65900" HTTP/1.1 304 Not Modified Date: Sun, 01 Jul 2012 18:52:16 GMT Server: Apache/2 Connection: Keep-Alive Keep-Alive: timeout=1, max=91 ETag: "2fc847-3e3-4c3969197d480" and large blocks of stuff like this: µàl]&BaËÜk#ìÏ

    Read the article

  • If I scp a file through an intermediate server, is the file stored temporarily on the server?

    - by Blacklight Shining
    For the sake of simplicity (I find it easier to remember names than arbitrary letters), I will dispense with letters and use names to refer to the machines in this scenario. Say I have two machines, applejack and pinkie-pie, each on their own separate LANs and not in the same physical location. I also have a server, cadance, with a direct Internet-facing connection. I want to copy a file from applejack to pinkie-pie, so to avoid dealing with port forwarding and such, I set up an ssh tunnel from pinkie-pie to cadance (ssh -R etc cadance). Now I can connect to pinkie-pie from anywhere, by connecting to cadance and specifying an alternate port to use. I can also easily copy files to pinkie-pie with scp -P $that_port $some_file cadance:$some_path. My understanding of how it works is this: A secure connection is made from applejack to cadance I am authenticated to cadance A secure connection is made from applejack to pinkie-pie that spans the existing reverse tunnel and the new connection from step 1. I am authenticated to pinkie-pie Files are copied directly from applejack to pinkie-pie over this connection. Am I correct here? How secure is this approach? If I'm wrong…are files copied this way decrypted at cadance before being passed on to pinkie-pie? Is there a possibility that traces of unencrypted data could remain on cadance?

    Read the article

  • How to set x509 Certificate private key access rights for AppPoolIdentity

    - by ChrisD
    If your website uses the AppPoolIdentity and requires access to the private key of an x509Certficate, you’ll need to grant the read permissions to the iis application pool.   To grant permissions to the AppPoolIdentity: Run Certificates.MMC (or Start->run->mmc.exe, Add Certificate Snap-In for LocalMachine) Select the certificate (Personal node on the certificate tree) , right click and Manage Permissions. Add a new user to the permissions list. Enter "IIS AppPool\AppPoolName" on the local machine". Replace "AppPoolName" with the name of your application pool.

    Read the article

< Previous Page | 166 167 168 169 170 171 172 173 174 175 176 177  | Next Page >