Search Results

Search found 4803 results on 193 pages for 'panel applets'.

Page 177/193 | < Previous Page | 173 174 175 176 177 178 179 180 181 182 183 184  | Next Page >

  • How to stop a random ramp in FCGI Processes Killing the server

    - by Andy Main
    So got the below earlier to day... Around that time the logs show a ramp in processes(600) and associated memory (1.2g), cpu usage load average (80) untill the server gave out. Server had to be hard reset by host as there was no ssh or plesk panel access. Fast CGI is configured as below and is setup for one high use site. As I understand it FcgidMaxProcesses 20 should protect against what happen but has not. I've read many forums with differing answers and references to many different fcgi directives, but have found nothing conclusive. Any one got some definitive answers on how to stop this sort of server process ramping and subsequent server failure? If you need more info let me know. Cheers Andy  /var/log/apache2/error_log [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17651 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17650 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17649 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17644 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17643 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17638 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17633 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17627 graceful kill fail, sending SIGKILL [Thu May 17 07:40:47 2012] [warn] mod_fcgid: process 17622 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17674 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17673 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17672 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17667 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17666 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17665 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17664 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17659 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17658 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17657 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17656 graceful kill fail, sending SIGKILL [Thu May 17 07:40:51 2012] [warn] mod_fcgid: process 17651 graceful kill fail, sending SIGKILL https://docs.google.com/a/thesugarrefinery.com/open?id=0B_XbpWChge0VRmFLWEZfR2VBb2M https://docs.google.com/a/thesugarrefinery.com/open?id=0B_XbpWChge0VWTcwZEhoV2Fqejg https://docs.google.com/a/thesugarrefinery.com/open?id=0B_XbpWChge0VUUtVWWFINHZjZ0U https://docs.google.com/a/thesugarrefinery.com/open?id=0B_XbpWChge0VZEVMclh6ZUdaOUE <IfModule mod_fcgid.c> <IfModule !mod_fastcgi.c> AddHandler fcgid-script fcg fcgi fpl </IfModule> FcgidIPCDir /var/lib/apache2/fcgid/sock FcgidProcessTableFile /var/lib/apache2/fcgid/shm FcgidIdleTimeout 40 FcgidProcessLifeTime 30 FcgidMaxProcesses 20 FcgidMaxProcessesPerClass 20 FcgidMinProcessesPerClass 0 FcgidConnectTimeout 30 FcgidIOTimeout 120 FcgidInitialEnv RAILS_ENV production FcgidIdleScanInterval 10 FcgidMaxRequestLen 1073741824 </IfModule>

    Read the article

  • Looking for a fiber optic "switch" or "router" for home use

    - by Shrout1
    The gist of my question: What is a "fiber optic" switch called? I.E. a layer 2 ethernet switch that uses fiber TX and RX connections and sends layer 2 network traffic between the fiber strands that are connected. Can someone purchase a dedicated fiber switch that does not have copper ethernet ports? What is the current average price of a device like this? Not necessarily looking for product endorsements, just information Might not make sense to go this route if it is too cost prohibitive What type of fiber connector is used for terminating a fiber strand into a jack on the wall? Can fiber be "patched" using two jacks and a "patch" cable? Is signal loss a concern with the longest runs at 100-200ft, a patch cable and media converters? The full story: My parents had unterminated fiber optic cable and terminated Cat5e run throughout their home when it was built in 2004. 10 years later the Cat5e isn't providing the throughput that my father needs to accomplish multiple streams of HD and fast system backups throughout the house. He can't reach gigabit speeds across the distance of the Cat5e runs. We are both interested in terminating the fiber connections and using them as high speed "backbones" to copper switches in each room of the house. It would be easy to attain gigabit speeds (or better, eventually) using the fiber. I have searched and searched for a "fiber optic switch" or "fiber optic router" and cannot find the correct term to describe this piece of hardware. We can use fiber media converters at the end points of each connection, however it would be nice to have a "patch panel" set up in the network closet in the basement that has fiber connections on it and switches the ethernet streams between the connections/systems in the house. Each fiber media converter costs between $50-$100 a piece... After 10 or so terminated connections it might make sense to find a piece of hardware that does not require media converters. That would depend upon the cost of this hardware Somewhat unrelated, if we are able to route between these fiber strands successfully, what is the physical connector type used in a jack on the wall? Just like RJ45 has a wall outlet (depicted below): What is the fiber optic equivalent of this? In the interim could we "patch" a couple fiber strands together in the network closet? Would signal loss be of concern with a run length of 100-200 feet, a patch cable and two media converters? If that would work then it could be used until the funds are available for more.

    Read the article

  • How to add IP range to a server?

    - by Efe Cakinberk
    Hello, First of all I must say that I'm ver inexperienced server and network user. But I rented a unmanaged dedicated server. Well I didn't know what unmanaged really means, then I learned it when I needed support. Well I must do everything by myself. I have a problem. I had already 4 IPs on my server when I rented it. But then I needed more Ips and my server assigned me 32 Ips in which I can only use 27 of them. 85.25.230.0 - 85.25.230.31 this is my Ip range and they say the following Ips must not be configured on the server: 85.25.230.0 - network address 85.25.230.1 - gateway address 85.25.230.2 - router redundancy 85.25.230.3 - router redundancy 85.25.230.31 - broadcast address But the problem is ok Ips are assigned to me but they are not setup on my server. How will I setup Ips to work on my server? I did this after my reseach on google: I used this command on command prompt: route add 85.25.230.0 mask 255.255.255.224 85.25.230.1 metric 1 if then it said OK!. and I thought they should be working. (btw, mask is given to me by my ISP and I don't know metric 1 and if means I just saw it on the net and write it here) I setup my domains via using Plesk Kontrol Panel. So i added one domain and setup one of my new Ips 85.25.230.5 to it. But no it is not working. When I visit the domain via browser, there is a Plesk page comes and says this domain is not configured on the server. Then I changed the domains Ip to one of my old Ips which are given to me with the server and which I have been using for my other domains for a long time. Ok in a second, domain started working. I set it back to my new Ip and domain did not work. As I said, I'm not an expert and do not now the logic. But I'm eager to learn. Can you tell me what might couse the problem and did I do wrong while setting up IP RANGE to my server, if so how can I set them up? Thank you, Efe

    Read the article

  • Installing Yaws server on Ubuntu 12.04 (Using a cloud service)

    - by Lee Torres
    I'm trying to get a Yaws web server working on a cloud service (Amazon AWS). I've compilled and installed a local copy on the server. My problem is that I can't get Yaws to run while running on either port 8000 or port 80. I have the following configuration in yaws.conf: port = 8000 listen = 0.0.0.0 docroot = /home/ubuntu/yaws/www/test dir_listings = true This produces the following successful launch/result: Eshell V5.8.5 (abort with ^G) =INFO REPORT==== 16-Sep-2012::17:21:06 === Yaws: Using config file /home/ubuntu/yaws.conf =INFO REPORT==== 16-Sep-2012::17:21:06 === Ctlfile : /home/ubuntu/.yaws/yaws/default/CTL =INFO REPORT==== 16-Sep-2012::17:21:06 === Yaws: Listening to 0.0.0.0:8000 for <3> virtual servers: - http://domU-12-31-39-0B-1A-F6:8000 under /home/ubuntu/yaws/www/trial - =INFO REPORT==== 16-Sep-2012::17:21:06 === Yaws: Listening to 0.0.0.0:4443 for <1> virtual servers: - When I try to access the the url (http://ec2-72-44-47-235.compute-1.amazonaws.com), it never connects. I've tried using paping to check if port 80 or 8000 is open(http://code.google.com/p/paping/) and I get a "Host can not be resolved" error, so obviously something isn't working. I've also tried setting the yaws.conf so its at Port 80, appearing like this: port = 8000 listen = 0.0.0.0 docroot = /home/ubuntu/yaws/www/test dir_listings = true and I get the following error: =ERROR REPORT==== 16-Sep-2012::17:24:47 === Yaws: Failed to listen 0.0.0.0:80 : {error,eacces} =ERROR REPORT==== 16-Sep-2012::17:24:47 === Can't listen to socket: {error,eacces} =ERROR REPORT==== 16-Sep-2012::17:24:47 === Top proc died, terminate gserv =ERROR REPORT==== 16-Sep-2012::17:24:47 === Top proc died, terminate gserv =INFO REPORT==== 16-Sep-2012::17:24:47 === application: yaws exited: {shutdown,{yaws_app,start,[normal,[]]}} type: permanent {"Kernel pid terminated",application_controller," {application_start_failure,yaws,>>>>>>{shutdown,>{yaws_app,start,[normal,[]]}}}"} I've also opened up the port 80 using iptables. Running sudo iptables -L gives this output: Chain INPUT (policy ACCEPT) target prot opt source destination ACCEPT tcp -- ip-192-168-2-0.ec2.internal ip-192-168-2-16.ec2.internal tcp dpt:http ACCEPT tcp -- 0.0.0.0 anywhere tcp dpt:http ACCEPT all -- anywhere anywhere ctstate RELATED,ESTABLISHED ACCEPT tcp -- anywhere anywhere tcp dpt:http ACCEPT tcp -- anywhere anywhere tcp dpt:http Chain FORWARD (policy ACCEPT) target prot opt source destination Chain OUTPUT (policy ACCEPT) target prot opt source destination In addition, I've gone to the security group panel in the Amazon AWS configuration area, and add ports 80, 8000, and 8080 to ip source 0.0.0.0 Please note: if you try to access the URL of the virtual server now, it likely won't connect because I'm not running currently running the yaws daemon. I've tested it when I've run yaws either through yaws or yaws -i Thanks for the patience

    Read the article

  • Why are the analoge stereo input and output of my M-Audio 24/96 soundcard not available to me in Ubu

    - by user37968
    I have installed Lucid on an old Mac PowerPC G4 desktop with a M-Audio Audiophile 24/96 soundcard. The only inputs and outputs I can select in the audio preferences are digital ones for the digital input and output. "lspci -v" shows the card as so: 0001:10:13.0 Multimedia audio controller: VIA Technologies Inc. ICE1712 [Envy24] PCI Multi-Channel I/O Controller (rev 02) Subsystem: VIA Technologies Inc. Device d634 Flags: bus master, medium devsel, latency 16, IRQ 53 I/O ports at 0440 [size=32] I/O ports at 04b0 [size=16] I/O ports at 04a0 [size=16] I/O ports at 0400 [size=64] Capabilities: <access denied> Kernel driver in use: ICE1712 Kernel modules: snd-ice1712 "cat /proc/asound/cards" as so: 0 [Tumbler ]: PMac Tumbler - PowerMac Tumbler PowerMac Tumbler (Dev 21) Sub-frame 0 1 [M2496 ]: ICE1712 - M Audio Audiophile 24/96 M Audio Audiophile 24/96 at 0x440, irq 53 "aplay -L" shows these as listed: pulse Playback/recording through the PulseAudio sound server front:CARD=Tumbler,DEV=0 PowerMac Tumbler, PowerMac Tumbler Front speakers front:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi Front speakers surround40:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.0 Surround output to Front and Rear speakers surround41:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.1 Surround output to Front, Center, Rear and Subwoofer speakers iec958:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi IEC958 (S/PDIF) Digital Audio Output I believe it is a problem with detecting the analogue input/output. Sometimes I can get sound from the device but it is a sheet of white noise and tinkering makes it go away again I don't know if that is a separate problem or if it is linked to not being able to see the analogue input/outputs in the sound preferences. Any help would be greatly appreciated As for the white noise I have installed the Envy24 control panel and spend lots of time playing with the settings but when I can get the white noise I can never get it to an quality where I can actually hear what is being played. The internal speaker plays audio fine and plugging in a NI Audio 4DJ via usb also plays sound, although with some static but I believe that is due to an underpowered usb2 pci expansion card not being able to get enough electricity to the device. Alternatively I have seen other people with problems with this device so it may be a bug in the driver but that is another matter. I would like to get the M-Audio card working so I can begin to enjoy my music once again. As a note, I do not currently have any audio equipment capable of sending or receiving audio via the digital inputs and output so I can not check if they are working. The sound preferences show a wide range of digital in and out options with various surround sound options but no analogue ins and outs.

    Read the article

  • How might I stop BACKSCATTER using Qmail?

    - by alecb
    New to ServerFault , please pardon if my details are too much Linux box acting as Virtual Host for domain hosting. Runs CentOs. Runs Parallels Plesk 9.x Regardless of the following, the SPAM keeps flowing in at 1-3 / second. An explanation of the problem... "xinetd service listens for SMTP connections and forwards to qmail-smtpd. The qmail service only process the queue, but does not control messages coming into the queue...that's why stopping it has no effect. If you stop xinetd AND qmail, then kill any open qmail-smtpd processes, all mail flow comes to a stop SOMETIMES Problem is, qmail-smtpd is not smart enough to check for valid mailboxes on the localhost before accepting the mail. So, it accepts bad mail with a forged replyto address which gets processed in the queue by qmail. Qmail cannot deliver locally and bounces to the forged replyto address." We believe the fix is to patch the qmail-smtpd process to give it the intelligence to check for the existence of local mailboxes BEFORE accepting the message. The problem is when we try to compile the chkuser patch we run into failures due to Plesk Control Panel." Is anyone aware of something we could do differently or better?" Other things that have NOT worked thus far: -Turning off any and all mail processes (to check as an indicator that an individual account has been compromised. This has been verified as NOT the case.) -Turning off mail AND http server processes (in the case of a compromised formmail) -Running EXIM in lieu of Qmail( easy/quick install but xinetd forces exim to close and restarts qmail on its own) -Turned on SPF protection via Plesk GUI. Does not help. -Turned on Greylisting via Plesk GUI. Does not help. -Disabled Bounce notifications via command line That which MIGHT work but have complications: -Use POSTFIX instead of QMAIL (No knowledge of POSTIFX and don't want to bother with it unless anyone knows it has potential to handle backscatter WELL before investing time) -As mentioned above, compiling a chkusr patch, we believe will STOP this problem, along with qmail (because of plesk in the mix, the comile fails every time and Parallels Plesk support is unresponsive unless I cough up MONEY) If I don't clear out the SPAM from the outgoing mail queue nightly, then it clogs up with millions of SPAMs and will bring down the OUTGOING email services. Any and all help welcome and appreciated!

    Read the article

  • Centos 5.5 [Read-only file system] issue after rebooting

    - by canu johann
    I have a virtual server under centos 5.5 (hosted by a japanese company called sakura ) Since yesterday, connection through ssh couldn't be established. I've contacted support center who told me to restart VS from the control panel. After restarting, I got the message below Connected to domain wwwxxxxxx.sakura.ne.jp Escape character is ^] [ OK ] Setting hostname localhost.localdomain: [ OK ] Setting up Logical Volume Management: No volume groups found [ OK ] Checking filesystems Checking all file systems. [/sbin/fsck.ext4 (1) -- /] fsck.ext4 -a /dev/vda3 / contains a file system with errors, check forced. /: Inodes that were part of a corrupted orphan linked list found. /: UNEXPECTED INCONSISTENCY; RUN fsck MANUALLY. (i.e., without -a or -p options) @@cat: /proc/self/attr/current: Invalid argument Welcome to CentOS Starting udev: @[ OK ] Setting hostname localhost.localdomain: [ OK ] Setting up Logical Volume Management: No volume groups found [ OK ] Checking filesystems Checking all file systems. [/sbin/fsck.ext4 (1) -- /] fsck.ext4 -a /dev/vda3 / contains a file system with errors, check forced. /: Inodes that were part of a corrupted orphan linked list found. /: UNEXPECTED INCONSISTENCY; RUN fsck MANUALLY. (i.e., without -a or -p options) [FAILED] *** An error occurred during the file system check. *** Dropping you to a shell; the system will reboot *** when you leave the shell. *** Warning -- SELinux is active *** Disabling security enforcement for system recovery. *** Run 'setenforce 1' to reenable. /etc/rc.d/rc.sysinit: line 53: /selinux/enforce: Read-only file system Give root password for maintenance (or type Control-D to continue): bash: cannot set terminal process group (-1): Inappropriate ioctl for device bash: no job control in this shell bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system bash: cannot create temp file for here-document: Read-only file system (Repair filesystem) 1 # setenforce 1 setenforce: SELinux is disabled (Repair filesystem) 2 # echo 1 (Repair filesystem) 4 # /etc/init.d/sshd status openssh-daemon is stopped (Repair filesystem) 5 # /etc/init.d/sshd start Starting sshd: NET: Registered protocol family 10 lo: Disabled Privacy Extensions touch: cannot touch `/var/lock/subsys/sshd': Read-only file system (Repair filesystem) 6 # sudo /etc/init.d/sshd start sudo: sorry, you must have a tty to run sudo (Repair filesystem) 7 # I have 4 site in production and I need to restart the server quickly (SSH + HTTPD ,...). Thank you for your time.

    Read the article

  • Why are the analoge stereo input and output of my M-Audio 24/96 soundcard not available to me in Ubuntu Lucid

    - by MIDoubleKO
    I have installed Lucid on an old Mac PowerPC G4 desktop with a M-Audio Audiophile 24/96 soundcard. The only inputs and outputs I can select in the audio preferences are digital ones for the digital input and output. "lspci -v" shows the card as so: 0001:10:13.0 Multimedia audio controller: VIA Technologies Inc. ICE1712 [Envy24] PCI Multi-Channel I/O Controller (rev 02) Subsystem: VIA Technologies Inc. Device d634 Flags: bus master, medium devsel, latency 16, IRQ 53 I/O ports at 0440 [size=32] I/O ports at 04b0 [size=16] I/O ports at 04a0 [size=16] I/O ports at 0400 [size=64] Capabilities: <access denied> Kernel driver in use: ICE1712 Kernel modules: snd-ice1712 "cat /proc/asound/cards" as so: 0 [Tumbler ]: PMac Tumbler - PowerMac Tumbler PowerMac Tumbler (Dev 21) Sub-frame 0 1 [M2496 ]: ICE1712 - M Audio Audiophile 24/96 M Audio Audiophile 24/96 at 0x440, irq 53 "aplay -L" shows these as listed: pulse Playback/recording through the PulseAudio sound server front:CARD=Tumbler,DEV=0 PowerMac Tumbler, PowerMac Tumbler Front speakers front:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi Front speakers surround40:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.0 Surround output to Front and Rear speakers surround41:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.1 Surround output to Front, Center, Rear and Subwoofer speakers iec958:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi IEC958 (S/PDIF) Digital Audio Output I believe it is a problem with detecting the analogue input/output. Sometimes I can get sound from the device but it is a sheet of white noise and tinkering makes it go away again I don't know if that is a separate problem or if it is linked to not being able to see the analogue input/outputs in the sound preferences. Any help would be greatly appreciated As for the white noise I have installed the Envy24 control panel and spend lots of time playing with the settings but when I can get the white noise I can never get it to an quality where I can actually hear what is being played. The internal speaker plays audio fine and plugging in a NI Audio 4DJ via usb also plays sound, although with some static but I believe that is due to an underpowered usb2 pci expansion card not being able to get enough electricity to the device. Alternatively I have seen other people with problems with this device so it may be a bug in the driver but that is another matter. I would like to get the M-Audio card working so I can begin to enjoy my music once again. As a note, I do not currently have any audio equipment capable of sending or receiving audio via the digital inputs and output so I can not check if they are working. The sound preferences show a wide range of digital in and out options with various surround sound options but no analogue ins and outs.

    Read the article

  • Outlook refuses to connect to Exchange

    - by wfaulk
    Outlook 2007 under Windows XP connecting to Exchange 2003 SP2: when started, it flips back and forth between "Connecting to Exchange Server" and "Disconnected" three or four times, then gives up and stays disconnected. I tried deleting the ost file (which was nearly 2GB), turning Cached mode on and off, recreating the account inside the Mail control panel, changing the account to use HTTP, and probably some other things. None of it seemed to make any difference, until … After fiddling with it for a while, I got this absurd error message dialog at startup, and it exits after I click OK: Cannot start Microsoft Office Outlook. Cannot open the Outlook window. The set of folders cannot be opened. Microsoft Exchange is not available. Either there are network problems or the Exchange server is down for maintenance. (I'm not sure if I can even trust that message. It's so long, it just feels like a random offset into Outlook's stack of error messages.) Either way, the Exchange server is available to everyone else, and is available via OWA from that computer. I ran Process Explorer against Outlook and it showed 5 or so ESTABLISHED connections to our Exchange server, plus listening on two UDP ports, and two CLOSE_WAIT connections to localhost. If I managed to look at Outlook's IP connections while it was doing its Connecting/Disconnected dance, it had a huge number of connections open to the Exchange server. It more than filled ProcExp's dialog box; I'm guessing at least 20, probably more. The only other odd thing is that our network admin at some point added a wildcard DNS record to the domain name that we use for email, and now Outlook will sometimes (always?) start by complaining about autodiscover.example.com's SSL certificate. There is a web server there, but it doesn't have any sort of email autodiscover anything on it. It doesn't make any difference if I click "OK" or "Cancel" (or whatever the buttons are). I also added a bogus entry for the hostname to Windows' hosts file, pointing it at 127.0.0.2, and it stopped complaining about the certificate. (The CLOSE_WAIT sockets above were from before I made this change, and went away after.) I don't think this is related, as the same problem should exist for everyone, but it might be. This is the second time this user has had this problem. The first time, I never found a solution other than reinstalling Outlook. Now that it's a pattern, I'd like to find a permanent solution, rather than assume it's a random glitch.

    Read the article

  • CPU overheating after cleaning it

    - by Roberts
    I wanted to clean my computer CPU heatsink and fan itself, because the temperature is not what I wanted. About (50C ~ 70C). I have Intel Core 2 Duo E4300 @1.8 GHz (LGA775). The heatsink wasn't so scary filled with dust but I wanted to clean it anyway. I didn't know how to get heatsink with fan from the socket. So after 25 minutes I've figured it out. But I didn't know how to get it back on so I spent a lot time getting out the motherboard from the case. The fan and heatsink... The case and all components are clear of dust. (I'm tired now). Then I put all back just the way it was, well did few things on cable management. But the problem was that I didn't know how to connect front audio connectors. I had Windows XP hibernated. So I started the PC and everything was normal, except CMOS memory was clear. I configured the BIOS just the way it was and while I was doing that I saw about 58C CPU temperature and fan at 1789 RPM. Restarted the computer with new settings applied. But Windows halted with Blue Screen (I forgot what error it was but something with KERNEL). Restarted the PC and deleted hibernation session and everything was back normal. But couldn't record any sound from front panel microphone. The problem was that I messed ground wire with mic. Again after fixing it I turned computer on. No problems. The fan currently is noisy and temperature was 78C. The temperature before was 55C - 60C at idle. Now it's about 60C. If I do something then temperature raises to 79C. While speaking in skype the temperature was 82C. Could this problem occur because of the thermal grease (it's old and never replaced)? Edit The problem wasn't in thermal paste (because I didn't touch it). The problem was that I installed heatsink wrong. Now instead of regular 60C CPU temperature the CPU is at 48C (cool).

    Read the article

  • Legacy VB6 application under Win7 SQL error

    - by Shial
    We have a rather unfortunate legacy application at work, written originally in VB6 it predates anybody in our IT department by at least 5 years. We have a contracted developer for ongoing maintenance and where he can he rewrites sections over into .NET code (Not sure about his techniques here, this is a side job for his regular work as an IBM engineer) the application works fine (such as it is) under windows XP. We have only a couple of Windows 7 machines mainly for testing and this application seems to run into a wall. Things like the background not loading and SQL errors. This is even running under administrator. Running an SQL trace from the ODBC control panel shows several interesting things. It makes a connection to the database successfully initially where it runs a query to determine if it is running the correct version. This query works fine. 558-1af0 ENTER SQLExecDirectW HSTMT 0x020D7548 WCHAR * 0x04C8F0F0 [ 115] "SELECT count(*) c FROM tblSoftwareVersion WHERE fldSoftwareVersion = '123456' AND fldSoftwareName = 'Application.VB'" SDWORD 115 BMS 558-1af0 EXIT SQLExecDirectW with return code 1 (SQL_SUCCESS_WITH_INFO) HSTMT 0x020D7548 WCHAR * 0x04C8F0F0 [ 115] "SELECT count(*) c FROM tblSoftwareVersion WHERE fldSoftwareVersion = '123456' AND fldSoftwareName = 'Application.VB'" SDWORD 115 It then seems to drop its connection and can't find the ODBC connection despite the fact its connecting to the same DB. From the trace it looks like it configures the connection then it starts firing off SQLFreeStmt to unbind and close out then when in the application and it tries to do its thing there is no connection. 558-1af0 ENTER SQLFreeStmt HSTMT 0x020D7548 UWORD 2 <SQL_UNBIND> BMS 558-1af0 EXIT SQLFreeStmt with return code 0 (SQL_SUCCESS) HSTMT 0x020D7548 UWORD 2 <SQL_UNBIND> Then this happens when I try to do something that pulls data 558-1af0 ENTER SQLDriverConnectW HDBC 0x020DDA00 HWND 0x00000000 WCHAR * 0x73EF8634 [ -3] "******\ 0" SWORD -3 WCHAR * 0x73EF8634 SWORD -3 SWORD * 0x00000000 UWORD 0 <SQL_DRIVER_NOPROMPT> BMS 558-1af0 EXIT SQLDriverConnectW with return code -1 (SQL_ERROR) HDBC 0x020DDA00 HWND 0x00000000 WCHAR * 0x73EF8634 [ -3] "******\ 0" SWORD -3 WCHAR * 0x73EF8634 SWORD -3 SWORD * 0x00000000 UWORD 0 <SQL_DRIVER_NOPROMPT> DIAG [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified (0) Nearly all of my searching on this issue comes up with programming issues where the connection string has a problem. The only thing that is different in this particular scenario though is Windows 7, I know the connection string is fine since it works on the XP machines. The VB components are supposed to be still functional under Win7. My computer is running 32 bit win7 and my VP is running Win7 64 bit and both have the same problem so that can be ruled out. I have already tried reinstalling the SQL Native Client and the VB runtime as well as the application in question. Hopefully I can find a solution and not have to resort to using the XP VM.

    Read the article

  • Is my Cisco switch port bad?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced last week, however the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link (switchport configuration pastebin). We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • Automatic layout of manual network mapping

    - by Paul
    So I have a small business network mainly consisting of two routed layer-2 domains with a total of ca. 100 devices spread over ca. 2000m² production and office spaces. Typical problems to solve using the graph would be: Over what (cable) path is a PC connected to the server? Where to expect devices connected to a switch port? I want to generate a graph of the physical network topology: Nodes are endpoint devices, switch ports, wall outlets, patch panel ports etc. Edges are cable connections. Ideally, grouping edges (or segments) that pass through the same bundle could be grouped. Also I would like to augment the graph data with automatically gathered data (monitoring state, MAC address, Switch port <- MAC entries to build up parts of the map). At the moment I use graphviz for this inside a Confluence wiki like that: layout = "neato" overlap = scale subgraph { rankdir = "TB" subgraph cluster_r1pf1 { r1pf1 [label="{ Rack 1 PF 1 | { <p1>P1 | <p2>P2 | <p3>P3} }", shape=record] } subgraph cluster_switch1 { switch1 [label="{ Rack 1 Switch 1 | { <p1> P1 | <p1> P1 | <p3> P3} }", shape=record] } r1pf1:p1 -> switch1:p1 (obviously there are dozens of entries omitted here) Problem is: I have a hard time to influence graphviz to generate a bearable layout. Edges overlap so bad that you can't read the diagram anymore. The question is: What other tools (be it interactive like Visio, Omnigraffle or I/O-oriented like graphviz) exist that would allow an easily versionable (as in: Operates on a text file) documentation that is both machine and human readable and editable? Why not OmniGraffle or Visio? Well we don't have Macs and Visio is not available at the moment. To buy it I would need good arguments. Automation would be one of that. But last time I looked, versioning Visio files or even thinking about automatic handling was a nightmare. Related: Network Mapping Tools basically asks the same with a focus on generating the complete graph automatically (but without the need to document cabling connections) Recommendations for automatic computer inventory brings up links of "all-in-one" solutions

    Read the article

  • Google Apps For Business, SSO, AD FS 2.0 and AD

    - by Dominique dutra
    We are a small company with 22 people in the office. We had a lot of problems with e-mail in the past so I decided to change over to Google Apps for Business. It is the perfect solution for us, except for one thing: I need to be able to control the access to the mailboxes. Only users inside the office, authenticated to AD, or users authenticated to our VPN can connect to gmail. From what I've read it is possible using the SSO (Single Sign On) solution provided by Google - but i am having some trouble finding consistent information about it. First of all, our infrastructure: Windows Server 2008 R2 Active Directory, one domain only. Kerio Control for QoS and VPN. That's about it on our side. On Google Apps' side, I have one account, and 03 domains that my users use to log in. The main domain has most of the users, but the are a couple of people that login using one of the subdomains. I have a 03 domains because I run mail for 03 companies and wanted all to be in within the same control panel. Well, I found some guides on the internet but none of them cover the AD FS installation part. I've read somewhere that I needed to download AD FS 2.0 directly from Microsoft.com, because the one that came with Windows Server was a old version. I downloaded it (adfsSetup.exe) and tried to install but got an error, saying that I needed a Windows Server 2008 Sp2 for that program. My Windows Server 2008 is R2. I really need some help here, this is very importand, I dont want to have to pay $1000 for a SSO solution when i have an AD set up. Can someone please point me out to the right direction? Where can I find an AD FS 2.0 setup compatible with R2 would be a good start, or the one that came with r2 is already the 2.0 version. After the initial setup, there are some guides on the internet about the Google Apps part. It seems to be really easy. I also tried adding AD FS role, but there are a bunch of options wich I have no idea what means, and I coudn't find any guide covering that on the internet. I dont have a lot of experience with Windows Server, but I have a company wich is certificated and provide us with support. I can ask for their help in the later setup, but I dont think ADFS is a very common thing to deal with.

    Read the article

  • Is it possible to change an "Unidentified Network" into a "Home" or "Work" network on Windows 7

    - by Rhys
    I have a problem with Windows 7 RC (7100). I frequently use a crossover network cable on WinXP with static IP addresses to connect to various industrial devices (e.g. robots, pumps, valves or even other Windows PCs) that have Ethernet network ports. When I do this on Windows 7, the network connection is classed as an "Unidentified Network" in Networks and Sharing Center and the public firewall profile is enforced by Windows. I do not want to change the public profile and would prefer to use the Home or Work profile instead. For other networks like Home and Work I'm able to click on them and change the classification. This is not available for unidentified networks. My questions are these:- Is there a way to manual override the "Unidentified Network" classification? What tests are performed on the network that fail, therefore classifying it as an "Unidentified Network" By googling (hitting mainly vista issues) it seems that you need to ensure that the default gateway is not 0.0.0.0. I've done this. I've also tried to remove IPv6 but this does not seem possible on Windows 7. UPDATE For those still having problems here is the answer to my issue and the possible reasons why:- Win7 keeps a list of the networks you visit by (I am assuming, but don’t know for sure) the MACID of the device pointed to by the Default Gateway. The default gateway is usually the constant device in a network (i.e. the NAT or router) so can be used to uniquely identify one network from another. The default gateway in the IPv4 properties panel must therefore point to an actual endpoint so windows can then keep track of it. If there is a device at the end of the Default Gateway windows will identify it and track it remembering its settings. The ways you can therefore fool Win7 is to either point the default gateway to your own IP address, or the IP address of the target device you’re communicating with. This will have the side effect of expecting that target device to start routing packets for IP destinations that are outside your subnet. So some applications on Win7 will try to communicate with the internet, these will be passed on to the default gateway (either back you the same IP address or a target device that is not a router) and thus will eventually timeout because neither can route packets. Which you can usually live with. This gets slightly complicated when you mix a this type of connection with a real connection to the internet via WIFI. The wired network card usually has priority when routing because of the “interface metric” so some applications might not connect correctly.

    Read the article

  • Managing multiple independant domains with Google Apps

    - by Saif Bechan
    I am currently running a server where I have multiple domains with all of them running there own mail server. My plan is to outsource this whole email service and have Google, or competitor, do this for me. Let me start by telling you the setup I have now and want to migrate to Google. Initial setup I have a main domain where I run my server, and my nameserver. This is an important domain because this holds the connection with all my internal applications. For example log messages, cronjob messages, and virus-scan messages are sent to this domain. This email is also registered at my registrar and I use it to communicate with my ISP. Next I run a few independent websites that all need their independent email addresses. This can be on shared space, I don't mind. 1 Gig will be enough for everything I am going to do. Summary: superdomain.com (which only has a catchall for internal use and communication with my ISP) cars.com (independent) flowers.com (independent) foods.com (independent) I am going to be the admin for all of this. The independent domains don't need there own admin panel, they just need email addresses like info@ support@, etc. I do all the managing and they just send and receive emails using the accounts i give them. All of the websites have there different staff that use the accounts. Tried so far I have registered my superdomain, but I can only add aliases to the main domain. If I make all the other domains aliases the emails from [email protected] and [email protected] will have the same inbox. I want them to be separate. is the only way to achieve this by creating an account for each domain? And if so, is there no way of creating a superdomain account where I can edit all these accounts easily without having to log in 4 different places to get my work done. I have searched the Google help forums, and posted questions but without any results so far. Questions Can anyone please give me some advice on what to do. I currently use the free program Google has.

    Read the article

  • Why Does My Windows 7 PC Freeze After Waking from Sleep?

    - by Blaenk
    Hey guys. I have Windows 7 running on my computer and everything is perfect. There's only one little problem. Sometimes when I leave my computer, I come back and my monitor is turned off or asleep, whichever it is. This is fine, I set it to do this. However, after turning on the monitor and moving the mouse around, the mouse cursor freezes; both the keyboard and mouse don't respond to anything, for example the keyboard's windows key won't bring up the start menu and moving the mouse around does not move the cursor around on the screen. I have to wait about a minute or two before things start working again. I figured this was a power savings setting problem, so I went into Control Panel Power Options. I only have Turn off Display = 30 minutes and Put Computer to Sleep = Never. Of course, I went into the advanced power settings to look through there. I put Never to turn off the hard disk, Sleep after never, and that's about it. Nothing else there looks like it might be causing this. I went into the device manager and checked the mouse and the keyboard, and they both have the Allow this device to wake the computer checked for both of them. Perhaps this other bit of information might help: Sometimes I VNC into my PC using my MacBook, and sometimes, as soon as it shows me the desktop, the same thing happens. The mouse won't move and VNC won't register any events on the server (Which is my PC of course). I close the client (And I know it has nothing to do with the client), then immediately restart it and try to connect. When I click the connect button, it hangs there, as if the PC is not responding. Basically it's like whenever I try to wake the computer from sleep, it does so by showing me the desktop, then it freaks out. Then again, I guess the computer isn't sleeping because the setting is set to 'Sleep after = Never'. I honestly don't know what's going on, would appreciate any insight. Thanks!

    Read the article

  • Change Logon DPI setting in Windows 8.1

    - by jmc302005
    I love how M$ keeps making decisions for me about how I want my desktop to look. Now they have added per-user dpi settings. The problem this has created is that there is no adjustable dpi setting for the Lock/Logon screen. Let me explain. you can change the dpi setting to be the same across all displays and this does affect the icons and font on the lock/logon screen. However it does not affect any app/program that can run on the lock/logon screen. Ex. I use a 44" flat screen tv for my monitor on my desktop. Big enough for me to sit in my recliner and use my comp. But I don't have a wireless keyboard. And it sucks having the wire from the keyboard running across the floor. Plus I really don't want to keep a keyboard next to me. So I use the on screen keyboard for logging in and quick typing (search, web address, etc.) So the problem is that with the new dpi setup my on screen keyboard takes up nearly half the screen. Does M$ think we are all blind? Oh no I remember they think desktops should look like tablets and phones. I tried looking through the registry to see if I could find a setting for it. In the key HKEY_USERS.DEFAULT\Control Panel\Desktop there is a string value named "LogicalDPIOverride" with a value of -1. I have a feeling this is where I can fix the issue. I tried changing the value to 0 and to 1 with no change in the result. Instead I noticed that after logging out and back in the -1 value was back in the registry. So now M$ has also added a way for us to not be able to change a setting in the registry. They are making it harder and harder for us power users to be able to do anything with the settings in windows. Soon we will all have the same exact Windows with absolutely no customization. ok sorry for the quick rant. The real question here is. How can I change this defualt dpi crap? Can I use the LogPixels string that worked for dpi in Windows 7? Here are 2 Screen shots 1 of the Lock Screen and 1 of the Logon Screen http://i.imgur.com/6RM5ufE.jpg http://i.imgur.com/cnY5bmm.jpg Please any help will be appreciated.

    Read the article

  • Can't Move Windows to 2nd Monitor without Left Mouse and Cntl Key

    - by John C
    I have 2 very frustrating problems that maybe someone can help me with: I have 2 monitors (different sizes and resolutions) setup with the "Extended" monitor Win7 setup. My problem is this = I can not "move" a window from my Primary Monitor (larger and higher resolution on right side in front of me) to my Secondary 2nd monitor (smaller and lower resolution) with just selecting the title bar with the left mouse button and dragging it to the left. Windows 7 "snaps" it back to the left Primary Monitor when the window is physically in the 2nd window area as I'm holding the left mouse button. I can prevent this problem - by holding down the Cntl Key with the Left Mouse button, but this is extremely annoying to me. Also I typically "lose" focus if I try typing input on the 2nd monitor. Typing is erratic with regard to keystroke accuracy from my keyboard translated into input on the 2nd screen. No problem with typing input on the primary left monitor. I find this extremely annoying in Windows 7 and turning off the "snap" feature via the Control panel does NOT work for me. Win7 stubbornly refuses to move my selected window to my 2nd monitor without me "forcing" Win7 to do this with the Cntrl Key. Please tell me this is not a Win7 feature. Also on my system - Windows Key + Shift, Left arrow Key (pressed together) or the same combo with The Right arrow Key - don't do anything whatsoever. Widows Key with "+" however does maximize current window across both monitors, and I can "restore" it with Windows Key and "-" back to original monitor and size. I have tried various solutions including changing the resolutions of one or both of my monitors and sometimes "temporarily helps" but reverts back to the problem. Also if I swap the logical (not physical) layout so that I tell Win7 the monitors are setup in a reserved situation (Large monitor on the left, and small on the right) - this also sometimes helps for awhile - and is very strange and awkward to work with "backwards". But all of these solutions stop working. The only solution that consistently works for "moving" the screens is to hold the Cntrl Key down as I'm moving window with the left mouse selected on the title bar. Even that however, doesn't prevent the loss of typing focus for me on the 2nd monitor - while at the same time the typing on the 1st monitor is fine. Any help on moving my window screens from one monitor on my 2nd monitor without having to press the Cntrl key while holding down my left mouse button with be appreciated. Also any help on gaining typing "focus" into my 2nd screen with be helpful too. Thanks - John

    Read the article

  • Some emails are being delivered, some returned

    - by Tom Broucke
    I have my own VPS where a site is running (control panel: directadmin). When I send mails, some are being delivered (hotmail, gmail, [email protected] ,...), others are not ([email protected]), others are delivered after being greylisted ([email protected]). /var/log/exim/mainlog What could be the cause of this? Is the problem Sender-Side or Receiver-Side? case 1: [email protected] (delivered) 2012-06-20 15:02:03 1ShKXr-0005Sc-7g <= [email protected] U=apache P=local S=1319 T="Password reset" from <[email protected]> for [email protected] 2012-06-20 15:02:03 1ShKXr-0005Sc-7g gmail-smtp-in-v4v6.l.google.com [2a00:1450:8005::1b] Network is unreachable 2012-06-20 15:02:03 1ShKXr-0005Sc-7g => [email protected] F=<[email protected]> R=lookuphost T=remote_smtp S=1355 H=gmail-smtp-in-v4v6.l.google.com [173.194.67.27] X=TLSv1:RC4-SHA:128 C="250 2.0.0 OK 1340196103 cp4si34336466wib.14" 2012-06-20 15:02:03 1ShKXr-0005Sc-7g Completed case 2: [email protected] (not being delivered) 2012-06-21 09:57:14 1ShcGQ-0007No-5H <= [email protected] H=localhost ([91.230.245.141]) [127.0.0.1] P=esmtpa A=login:[email protected] S=740 [email protected] T="hey" from <[email protected]> for [email protected] 2012-06-21 09:57:14 1ShcGQ-0007No-5H ** [email protected] F=<[email protected]> R=virtual_aliases: 2012-06-21 09:57:14 1ShcGQ-0007Nt-7Z <= <> R=1ShcGQ-0007No-5H U=mail P=local S=1546 T="Mail delivery failed: returning message to sender" from <> for [email protected] 2012-06-21 09:57:14 1ShcGQ-0007No-5H Completed 2012-06-21 09:57:14 1ShcGQ-0007Nt-7Z => info <[email protected]> F=<> R=virtual_user T=virtual_localdelivery S=1643 2012-06-21 09:57:14 1ShcGQ-0007Nt-7Z Completed case 3: [email protected] (greylisted) 2012-06-21 15:29:02 1ShhRW-000862-BV <= [email protected] H=localhost ([91.230.245.141]) [127.0.0.1] P=esmtpa A=login:[email protected] S=782 [email protected] T="testmail squirrel" from <[email protected]> for [email protected] 2012-06-21 15:29:02 1ShhRW-000862-BV SMTP error from remote mail server after RCPT TO:<[email protected]>: host mx-cluster-b1.one.com [195.47.247.194]: 450 4.7.1 <[email protected]>: Recipient address rejected: Greylisted for 5 minutes 2012-06-21 15:29:02 1ShhRW-000862-BV == [email protected] R=lookuphost T=remote_smtp defer (-44): SMTP error from remote mail server after RCPT TO:<[email protected]>: host mx-cluster-b2.one.com [195.47.247.195]: 450 4.7.1 <[email protected]>: Recipient address rejected: Greylisted for 5 minutes Notice that the "from" in case1 differs in case2: [email protected] or [email protected]. Thanks for your time!

    Read the article

  • PHP versions warning on Plesk 11.0.9 upgrade on CentOS server

    - by Pixman
    I have a server turning on Plesk 10.4.4 and I want to upgrade it to 11.0.9. When I use the online upgrade tool, I have this warning: Parallels Panel pre-upgrade check... WARNING: You have a mixed set of 'php' and 'php53' packages installed. Installation or upgrade may fail or produce unexpected results. To resolve this issue run "sed -i.bak -e '/^\s*skip-bdb\s*$/d' /etc/my.cnf ; yum update 'php*' 'mysql*'". PHP Warning: Directive 'safe_mode' is deprecated in PHP 5.3 and greater in Unknown on line 0 I have run the code in ssh, but nothing changes. I have already searched all package names with "php", and I have this list: # yum list installed | grep php php-common.i386 5.3.13-5.el5.art installed php-pear.noarch 1:1.4.9-8.el5 installed php5-ioncube-loader.i386 4.0.7-11062118 installed php53.i386 5.3.3-13.el5_8 installed php53-cli.i386 5.3.3-13.el5_8 installed php53-devel.i386 5.3.3-13.el5_8 installed php53-gd.i386 5.3.3-13.el5_8 installed php53-imap.i386 5.3.3-13.el5_8 installed php53-mbstring.i386 5.3.3-13.el5_8 installed php53-mcrypt.i386 5.3.3-1.el5 installed php53-mysql.i386 5.3.3-13.el5_8 installed php53-pdo.i386 5.3.3-13.el5_8 installed php53-sqlite2.i386 5.3.2-11041315 installed php53-xml.i386 5.3.3-13.el5_8 installed psa-appvault-phpads.noarch 2.0.8-8203520080409011611 installed psa-appvault-phpbb.noarch 3.0.0-8200820080409011626 installed psa-appvault-phpbook.noarch 1.50-8203220080409011638 installed psa-appvault-phpbugtracker.noarch 1.19-8203820080416050605 installed psa-appvault-phpdig.noarch 1.85-8203120080409011645 installed psa-appvault-phpmoney.noarch 1.3-8204320080409011649 installed psa-appvault-phpmyfamily.noarch 1.4.1-8203420080409011655 installed psa-appvault-phpmyvisites.noarch 2.3-8202820080409011701 installed psa-appvault-phprojekt.noarch 5.2-8200820080409011713 installed psa-appvault-phpsurveyor.noarch 0.98-8204320080409011723 installed psa-appvault-phpwebsite.noarch 0.10.2-8203420080409011738 installed psa-appvault-phpwiki.noarch 1.3.11-8204320080409011808 installed psa-php53-configurator.i386 1.6.1-cos5.build1013111101.14 installed After verification in the Plesk file: panel_preupgrade_checker.php I think the warning is due to these lines: (from : panel_preupgrade_checker.php) foreach ($packages as $package) { $name = $package['name']; $hasPhp5 |= ($name == 'php' || strpos($name, 'php-') === 0); $hasPhp53 |= (strpos($name, 'php53') === 0); } Now, I think the problem is just due to the names of theses packages: php-common.i386 5.3.13-5.el5.art installed php-pear.noarch 1:1.4.9-8.el5 installed Can you help me to resolve this situation?

    Read the article

  • When upgrading from Vista to Windows 7 on a DELL laptop, how do I know which drivers to reinstall an

    - by msorens
    According to Dell's upgrade page for Vista to Windows 7, after using the upgrade assistant the final step is to install drivers. They refer to this page for the order of driver installation, listing 9 items. From there I go to the Dell Drivers and Downloads page, enter my system tag, and get a list of the downloads available for my specific box. That page, by the way, has a link to driver install instructions that lists 10 rather than 9 items. Going to Drivers Help in the side panel and clicking on "In what order should drivers be installed?" shows yet a third list, this one containing 13 items. Not surprisingly, the order of these 3 lists of drivers are not quite the same for the common items! Furthermore, of the 26 files Dell's site recommends for my machine, there are several not shown on any of the 3 lists! I can make determinations for some of these: 6 of them are "applications" so I know which of those I want and that they could probably be safely installed after all drivers. BIOS: I would think this should be unaffected by an OS upgrade so could be skipped. Two tools in the diagnostics category: could probably be done after all drivers. That leaves just a CD/DVD driver and a webcam driver unaccounted for. So my two related questions are these: How critical is the driver installation order and which one do I follow? (Keep in mind this is for an upgrade, not a fresh install.) Where in the order do I insert the CD/DVD and the webcam drivers (if needed) ? Dell's driver download page provides (in theory) the list of all downloads relevant to my specific machine, via the service tag. But do I actually need to reinstall all of them? some? none? How does one determine this? They do label each with Recommended or Optional, so do I need to reinstall all the recommended ones? (Part of the reason for my perplexed frown is that I wonder why I would need to reinstall a CD/DVD driver since I would already be using the drive to install the OS!)

    Read the article

  • How to temporary disable a mirror video driver in windows xp registry

    - by happy clicker
    Because its a lot of text, I will ask first my question and then explain what the base problem is. Perhaps someone can give me a solution to the base problem: Is there is a way to temporary disable mirror video drivers (through registry or so), without uninstalling the corresponding software. I tested changing the enumeration in LocalMachine\Hardware\DeviceMap\Video but after reboot always the old configuration is restored. Explanation of the base problem We are working on a wpf-project for a department of a big company. There we have the problem that WPF renders only in software mode, although the hardware they have, must support hardware rendering (Tier 2). After searching for a solution to the problem, we found out that direct 3d does not work properly and we think thats why WPF can only use SW-rendering. In dxdiag.exe the direct3d-acceleration is enabled, but if we start the test-routine it always fails saying that it has not enough memory (it says memory, not video memory!). I have seen there 3 different types of pc’s (they have some hundreds of each type) and every type shows the exactly same behavior. We tried to update all the drivers, also dx (Version 9.0c) and we searched a lot in the web but could not find a solution. All the pcs have Intel Dual-Core processors or better, one type has an Intel gma 9000 graphics card the other two types have actual ATI and NVidia graphic-cards with 256MB onboard memory. Also the system memory is at least 2GB. Windows is XPSP3. The pc’s are of two different manufacturers. Because we see the exactly same behavior on every computer of this three very different computer-types, we don’t think that this is a driver or a direct x problem. What we’ve found in other newsgroups is, that direct x could be disturbed through mirror-video drivers such as NetMeeting, VNC and other remote desktop-installations. In the registry, we see under LocalMachine\Hardware\DeviceMap\Video a lot of such mirror-entries and we find also the definitions in the CurrentControlSet\Control\Video-Section (However this drivers are not shown in the hardware panel of the os). We can have admin-rights to one of these computers to test if disabling these drivers would help, but we must not change the configuration so that some software does not work after the tests. Therefore I cannot uninstall any software because I have not the mediums, licenses or knowhow to reinstall those apps. The support of this company however will only begin to work, if I can tell them what the real problem is. Thats why we search for a way to disable these mirror-drivers (or a hint to solve the dx problem if we are on a false trace)

    Read the article

  • One user sometimes gets an unknown certificate error opening Outlook

    - by Chris
    Let me clarify a little. This isn't an unknown certificate error it's an unknown certificate error in so much as I can't figure out where the certificate comes from. This happens on a Win 7 Enterprise machine connecting to Exchange 2010 with Outlook 2010. The error he gets is that the root is not trusted because it's a self-signed cert. Take a look at this screenshot because even if I had generated this myself I wouldn't have put "SomeOrganizationalUnit" or "SomeCity" or "SomeState", etc. (Red block covers our domain name.) I'm a little concerned this is a symptom of a security breach. Exchange 2010 has three certificates installed but none of them are this certificate. They all have different expiration dates (one is expired) and different meta-data. edit: There are two scenarios that I see the certificate warning and one of them I can reliably repeat. When the user leaves his computer on over night Outlook pops the Security Warning window. I don't know what time this happens. Using Outlook Anywhere if I connect to Exchange externally via a cellular USB modem the Security Warning window will appear every time I close and reopen Outlook. Whether I say Yes or No does not make a difference on whether or not I can connect to Exchange and send/receive email. In other words, I can always connect to Exchange. I've checked my two Exchange servers and my Cisco router for a certificate that matches this one and I can't find it. edit 2: Here is a screenshot of the Security Alert window. (I've been calling it Security Warning... My mistake.) edit 3: I stopped seeing this error several weeks ago but I can't tie it to any single event (because I just sort of realized that warning had stopped showing up) but I think I found the source of the certificate. Last week I found out that the certificate on our website DomainA.com was invalid. I knew that our web admin had installed a valid certificate so when I look into the problem I found out I was being presented with the invalid certificate that this posting is in regards to. The Exchange server's domain is mail.DomainA.com so I can only guess that Outlook was passing this invalid certificate through as it did some kind of check on DomainA.com. This issue is still a mystery because the certificate warning stopped appearing several weeks ago whereas the invalid certificate issue on the website was only fixed last week. It ended up being a problem with the website control panel. The valid certificate was installed but not being served for some reason and instead the self-signed cert was being served.

    Read the article

  • Creating a really public Windows network share

    - by Timur Aydin
    I want to create a shared folder under Windows (actually, Windows XP, Vista, and Win 7) which can be mounted from a linux system without prompting for a username/password. But before attempting this, I first wanted to establish that this works between two Windows 7 machines. So, on machine A (The server that will hold the public share), I created a folder and set its permissions such that Everyone has read/write access. Then I visited Control Panel - Network and Sharing Center - Advanced Sharing Settings and then selected "Turn off password protected sharing". Then, on machine B (The client that wants to access the public share with no username/password prompt), I tried to "map network driver" and I was immediately prompted by a password prompt. Some search on google suggested changing "Acconts: Limit local account use of blank passwords to console logon only" to "Disabled". Tried that, no luck, still getting username/password prompt. If I enter the username/password, I am not prompted for it again and can use the share as long as the session is active. But still, I really need to access the share without any username/password transaction whatsoever and this is not just a convenience related thing. Here is the actual reason: The device that will access this windows network share is an embedded system running uclinux. It will mount this share locally and then play media files. Its only user interface is a javascript based web page. So, if there is going to be any username/password transaction, I would have to ask the user to enter them over the web page, which will be ridiculously insecure and completely exposed to packet sniffing. After hours of doing experiments, I have found one way to make this happen, but I am not really very fond of it... I first create a new user (shareuser) and give it a password (sharepass). Then I open Group Policy Editor and set "Deny log on locally" to "A\shareuser". Then, I create a folder on A and share it so that shareuser has Read access to it. This way, shareuser cannot login to A, but can access the shared folder. And, if someone discovers the shareuser/sharepass through network sniffing, they can just access the shared folder, but can't logon to A. The same thing can be achieved by enabling the Guest user and then going to Group Policy Editor and deleting the "Guest" from the "Deny access to this computer from the network" setting. Again, Guest can mount the public share, but logging in to A as Guest won't be possible, because Guest is already not allowed to log in by default. So my question would be, how can I create a network share that is truly public, so that it can be mounted from a linux machine without requiring a password? Sorry for the long question, but I wanted to explain the reason for really needing this...

    Read the article

< Previous Page | 173 174 175 176 177 178 179 180 181 182 183 184  | Next Page >