Search Results

Search found 5554 results on 223 pages for 'cool cs'.

Page 185/223 | < Previous Page | 181 182 183 184 185 186 187 188 189 190 191 192  | Next Page >

  • Data Type Not Consistent In MS Access? (Set new field as "TEXT" but system treats it as "Yes/No" field)

    - by user3522506
    I already have an SQL command that will insert any string in the field. But it doesn't accept any string, giving me "No value given for one or more required parameters". But if my string is "Yes" or "No", it will update successfully. And in MS Access, will appear as 0 or -1 even though I set the field as text even in the beginning. Could there be any configuration I have made in my MS Access 2007? con = New OleDbConnection(cs) con.Open() Dim cb As String = "Update FS_Expenses set FS_Date=#" & dtpDate2.Text & "#,SupplierID='" & txtSupplierID.Text & "', TestField=" & Label1.Text & " where ID=" & txtID2.Text & "" cmd = New OleDbCommand(cb) cmd.Connection = con cmd.ExecuteReader() MessageBox.Show("Successfully updated!", "Record", MessageBoxButtons.OK, MessageBoxIcon.Information) con.Close() TestField is already a TEXT data type, Label1.Text value is "StringTest", will give the error. However, set Label1.Text value as = "Yes", SQL will execute successfully. Therefore, field must have not been saved as TEXT.

    Read the article

  • BIOS upgrade lowers CPU temperature

    - by N.N.
    Setup I've got a system with an Asus P8Z68-V PRO motherboard and an Intel Core i7-2600K CPU running at stock speed (no overlocking) which I cool with a Noctua NH-U12P. On the heatsink I've got the two included fans connected via the included Low-Noise Adapters (L.N.A.) 1100 RPM, 16.9 dB(A). In the BIOS settings I've set the CPU and chassis fan profile to silent. Issue Yesterday I upgraded from BIOS version 0501 to 0606. After the upgrade I checked the temperatures in the BIOS monitor and was surprised to see that the CPU temperature was slightly ~30°C. Before the upgrade the CPU temperature was ~50°C with the same BIOS settings (see the following heading for details on temperatures). How can this be? It seems a bit odd that a BIOS upgrade can lower the CPU temperature by 20°C and it also seems odd that the CPU temperature is lower than the chassis temperature. Temperatures When I've checked temperatures the room temperature has been ~23°C. I haven't changed the placement of the computer nor the hardware or cooling setup between BIOS versions. BIOS version 0501 BIOS monitor: CPU: ~50°C Chassis: ~33°C I haven't got any temperature measures from lm-sensors or the like for version 0501 because I only discovered the issue after upgrading to version 0606 and the BIOS updater utility won't let me downgrade to version 0501 (it says "outdated image" when I try to load version 0501). BIOS version 0606 BIOS monitor: CPU: ~30°C Chassis: ~33°C lm-sensors in Ubuntu 11.04 Desktop 64-bit (sudo sensors after an uptime of 4 h 52 min and a load average of 0.22, 0.18, 0.15): coretemp-isa-0000 Adapter: ISA adapter Core 0: +32.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0001 Adapter: ISA adapter Core 1: +35.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0002 Adapter: ISA adapter Core 2: +29.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0003 Adapter: ISA adapter Core 3: +36.0°C (high = +80.0°C, crit = +98.0°C) The BIOS monitor temperatures was checked directly after the lm-sensors temperatures was checked. BIOS version 0706, 0801, 1101 and 3203 I get the same kind of temperatures both in the BIOS monitor and with lm-sensors in BIOS version 0706, 0801, 1101 and 3203 as in 0606. Information from Asus The 0606 changelog mentions nothing explicitly about CPU temperature (but item 3., as indicated by sidran32, might affect temperatures): P8Z68-V PRO 0606 BIOS with IRST 10.6.0.1002 Enable the support of Intel Rapid Storage Technology version 10.6.0.1002 Release Improve DRAM compatibility Improve System stability Improve compatibility with some Raid card model Increase IGD share memory size to 512MB However the following FAQ might give a hint: FAQs I find that the CPU temperature reading in BIOS is about 10~20 degrees centigrade hotter than the reading in OS. Is it normal? Page Tools Solution That is normal as BIOS does not send idle command to the CPU, making most of the power saving features useless. You should be getting similar reading if you disable EIST/C1E/CPU C3 Report/CPU C6 Report in BIOS.

    Read the article

  • vSphere Client vCenter Template Customization Specification Using Windows Sysprep Unattended Answer XML File

    - by Brian
    I'm trying to setup a vSphere Client vCenter v5.0.0 Build 455964 Template Customization Specification using a Windows Sysprep unattended answer XML file for Win2008R2. However I didn't know how Sysprep worked before attempting this so it was a time-consuming nightmare (even after reviewing VMware vSphere ESXi 5's documentation)! I think I've figure out what I'm supposed to be doing, but it's still not working. The biggest problem at this point is that vSphere Client vCenter Customization Specification IP address information is not sticking when I load a Sysprep XML file with just 1 basic setting! This can only be a bug. Here is the process I'm using: PROCESS for Windows - vSphere Client Install Windows OS install VM Tools customize Windows (GPOs can be used to do this after deployment) install Applications (GPOs can be used to do this after deployment too) shutdown the VM convert the VM to a template create a custom Windows Sysprep XML answer file with desired customizations View Management Customization Specifications Manager create "New" Specification for "Target Virtual Machine OS" select Windows check "Use Custom Sysprep Answer File" (ADDS: Custom Sysprep File. KEEPS: Network (IP), Operating System Options (SID, Sysprep /generalize). REPLACES: Registration Information of Owner Name & Organization, Computer Name, Windows License (Key), Administrator Password, Time Zone, Run Once, Workgroup or Domain) name it as "VMwareCS-OS####R#x32/64w/Sysprep-TEST" (CS=Customization Specification) set Description as "Created YYYY/MM/DD by FLast" NEXT import a Sysprep answer file from secure location NEXT Custom settings NEXT click "..." box to right of "Use DHCP" set "Use the following IP settings:" for "IP Address" fill out the first 2 octets set appropriate values for other 2-3 fields set DNS server addresses OK NEXT check "Generate New Security ID (SID)" ALWAYS as template is likely a domain-member computer so it can be updated occasionally NEXT Finish View Inventory VMs and Templates right-click previously completed template Deploy Virtual Machine from this Template provide the new OS name (max15char) select inventory location NEXT select Host/Cluster (wait for validation to succeed) NEXT select Resource Pool (wait for validation to succeed) NEXT select Storage location NEXT check "Power on this virtual machine after creation" select "Customize using an existing customization specification" select desired specification select "Use the Customization Wizard to temporarily adjust the specification before deployment" NEXT NEXT Custom settings? NEXT check "Generate New Security ID (SID)" ALWAYS as template is likely a domain-member computer so it can be updated occasionally NEXT Finish Finish. I know a community member named "brian" (http://serverfault.com/users/25904/brian) has worked with this scenario before, but I couldn't figure out how to contact him directly, so Brian if you see this message could you provide some information to help? Thanks, Brian

    Read the article

  • How to change SMP affinity of an IRQ on Ubuntu domU inside Xen XCP?

    - by Alexander Gladysh
    I'd like to change IRQ SMP affinity for reasons, outlined in this question: CPU0 is swamped with eth1 interrupts But I can't — I see Input/output error when I try to write to /proc/irq/*/smp_affinity. Please point me to the HOWTO on the matter. (A formal reference on /proc/irq/*/ would be cool as well.) Gory details: Note that this is a VM inside an Ubuntu-based Xen XCP host. $ uname -a Linux MYHOST 2.6.38-15-virtual #59-Ubuntu SMP Fri Apr 27 16:40:18 UTC 2012 i686 i686 i386 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 11.04 Release: 11.04 Codename: natty $ sudo cat /proc/irq/*/smp_affinity 01 01 01 01 01 80 80 80 80 80 80 40 40 40 40 40 40 20 20 20 20 20 20 10 10 10 10 10 10 08 08 08 08 08 08 04 04 04 04 04 04 02 02 02 02 02 02 01 01 01 01 01 01 Update. The error details: $ N=$(grep -c processor /proc/cpuinfo) $ echo $N 8 $ printf %x $((2**N-1)) ff $ printf %x $((2**N-1)) | sudo tee /proc/irq/*/smp_affinity fftee: /proc/irq/288/smp_affinity: Input/output error tee: /proc/irq/289/smp_affinity: Input/output error tee: /proc/irq/290/smp_affinity: Input/output error tee: /proc/irq/291/smp_affinity: Input/output error tee: /proc/irq/292/smp_affinity: Input/output error tee: /proc/irq/293/smp_affinity: Input/output error tee: /proc/irq/294/smp_affinity: Input/output error tee: /proc/irq/295/smp_affinity: Input/output error tee: /proc/irq/296/smp_affinity: Input/output error tee: /proc/irq/297/smp_affinity: Input/output error tee: /proc/irq/298/smp_affinity: Input/output error tee: /proc/irq/299/smp_affinity: Input/output error tee: /proc/irq/300/smp_affinity: Input/output error tee: /proc/irq/301/smp_affinity: Input/output error tee: /proc/irq/302/smp_affinity: Input/output error tee: /proc/irq/303/smp_affinity: Input/output error tee: /proc/irq/304/smp_affinity: Input/output error tee: /proc/irq/305/smp_affinity: Input/output error tee: /proc/irq/306/smp_affinity: Input/output error tee: /proc/irq/307/smp_affinity: Input/output error tee: /proc/irq/308/smp_affinity: Input/output error tee: /proc/irq/309/smp_affinity: Input/output error tee: /proc/irq/310/smp_affinity: Input/output error tee: /proc/irq/311/smp_affinity: Input/output error tee: /proc/irq/312/smp_affinity: Input/output error tee: /proc/irq/313/smp_affinity: Input/output error tee: /proc/irq/314/smp_affinity: Input/output error tee: /proc/irq/315/smp_affinity: Input/output error tee: /proc/irq/316/smp_affinity: Input/output error tee: /proc/irq/317/smp_affinity: Input/output error tee: /proc/irq/318/smp_affinity: Input/output error tee: /proc/irq/319/smp_affinity: Input/output error tee: /proc/irq/320/smp_affinity: Input/output error tee: /proc/irq/321/smp_affinity: Input/output error tee: /proc/irq/322/smp_affinity: Input/output error tee: /proc/irq/323/smp_affinity: Input/output error tee: /proc/irq/324/smp_affinity: Input/output error tee: /proc/irq/325/smp_affinity: Input/output error tee: /proc/irq/326/smp_affinity: Input/output error tee: /proc/irq/327/smp_affinity: Input/output error tee: /proc/irq/328/smp_affinity: Input/output error tee: /proc/irq/329/smp_affinity: Input/output error tee: /proc/irq/330/smp_affinity: Input/output error tee: /proc/irq/331/smp_affinity: Input/output error tee: /proc/irq/332/smp_affinity: Input/output error tee: /proc/irq/333/smp_affinity: Input/output error tee: /proc/irq/334/smp_affinity: Input/output error tee: /proc/irq/335/smp_affinity: Input/output error Update. irqbalance is running: $ sudo service irqbalance status irqbalance start/running, process 560

    Read the article

  • Home and Small to Medium Enterprise network manufacturer choice, Netgear, Linksys or D-Link ?

    - by Kedare
    (Please don't close this post, it's a serious post so... Be cool, no trolls please, I need an answer ;p) Hello, I am looking for an alternative to Cisco (too expensive for me !) for semi-pro utilization (at home but with advanced feature (I'm studying in IT)) and in small/medium enterprises. I think I will choose between LinkSys (Including Cisco Small Business), Netgear and D-Link, but I've never really used these products, that what I need is a manufacturer that make "almost" all type of networking equipment (Like Cisco but cheaper..), here are my needs : I need almost all my products to be rackable I need a good warranty (Netgear lifetime waranty rulez!) I need an "unified" network environment I made a little comparison of the characteristics that interest me after hours of search on Internet (based on result found on many websites): (Prices are based on the ldlc-pro.com french website) Hotline/Support Quality: Netgear : Not so bad Linksys : Not so bad D-Link : Poor! Most common Warranty: Netgear : Unlimited Lifetime Warranty! Linksys : Limited 3 years warranty D-Link : Limited 5 years warranty (Unlimited in US but I'm on France :(...) VPN protocols compatibles with routers on endpoint mode: Netgear : Only IPSEC :( Linksys : IPSEC, PPTP, L2TP D-Link : IPSEC, PPTP, L2TP Cheaper 8 ports Gb switch : Netgear : 30€ Linksys : 47€ D-Link : 30€ Cheaper 48 ports + 1Gb uplink(s) administrable switch : Netgear : 263€ Linksys : 630€ D-Link : 600€ Cheaper VPN router : Netgear : 100€ Linksys : 80€ D-Link : 60€ Cheaper rackable switch : Netgear : 50€ Linksys : 87€ D-Link : 50€ Cheaper rackable and administrable switch : Netgear : 120€ Linksys : 370€ D-Link : 171€ Netgear and D-Link are in the same range of price, where Linksys is more expensives. I've searched for some other criteria ( the full comparison is here, in french with shop/source links: http://forums.jeuxonline.info/showthread.php?t=1072280 ) and made a final score for each manufacturer : SCORE including IP camera sub-score: Netgear : 6.2/10 Linksys : 7.3/10 D-Link : 7.0/10 SCORE excluding IP camera sub-score: Netgear : 6.9/10 Linksys : 7.0/10 D-Link : 6.7/10 On both case, Linksys wins. So here is my little comparison, but because I've never really used these stuffs, I need your help to make a decision on witch manufacturer choose for both my personnal and corporate use. So here are the questions : What manufacturer do you recommend me (Not cisco (except Small business)) ? Why ? Have you called the call center of the customer support of one of these manufacturer ? How it was ? Did you had problems or bad experiences with these equipments ? Any other advices ? ;) Thank you !

    Read the article

  • UNIX - mount: only root can do that

    - by Travesty3
    I need to allow a non-root user to mount/unmount a device. I am a total noob when it comes to UNIX, so please dumb it down for me. I've been looking all over teh interwebz to find an answer and it seems everyone is giving the same one, which is to modify /etc/fstab to include that device with the 'user' option (or 'users', tried both). Cool, well I did that and it still says "mount: only root can do that". Here are the contents of my fstab: # /etc/fstab: static file system information. # # Use 'vol_id --uuid' to print the universally unique identifier for a # device; this may be used with UUID= as a more robust way to name devices # that works even if disks are added and removed. See fstab(5). # # proc /proc proc defaults 0 0 # / was on /dev/mapper/minicc-root during installation UUID=1a69f02a-a049-4411-8c57-ff4ebd8bb933 / ext3 relatime,errors=remount-ro 0 1 # /boot was on /dev/sda5 during installation UUID=038498fe-1267-44c4-8788-e1354d71faf5 /boot ext2 relatime 0 2 # swap was on /dev/mapper/minicc-swap_1 during installation UUID=0bb583aa-84a8-43ef-98c4-c6cb25d20715 none swap sw 0 0 /dev/scd0 /media/cdrom0 udf,iso9660 user,noauto,exec,utf8 0 0 /dev/scd0 /media/floppy0 auto rw,user,noauto,exec,utf8 0 0 /dev/sdb1 /mnt/sdcard auto auto,user,rw,exec 0 0 My thumb drive partition shows up as /dev/sdb1. I'm pretty sure my fstab is set up OK, but everyone on the other posts seems to fail to mention how they actually call the 'mount' command once this entry is in the fstab file. I think this is where my problem may be. The command I use to mount the drive is: $ mount /dev/sdb1 /mnt/sdcard. /bin/mount is owned by root and is in the root group and has 4755 permissions. /bin/umount is owned by root and is in the root group and has 4755 permissions. /mnt/sdcard is owned by me and is in one of my groups and has 0755 permissions. My mount command works fine if I use sudo, but I need to be able to do this without sudo (need to be able to do it from a PHP script using shell_exec). Any suggestions? Sorry for making you read so much...just trying to get as much info in the initial post as possible to preemptively answer questions about configuration stuff. If I missed anything tho, ask away. Thanks! -Travis

    Read the article

  • Determining the health of a Cisco switch port?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced recently, however, the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link. We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • Help with Windows 7 BSOD with windbg minidump !analyze -v results

    - by Kurt Harless
    Hi gang, Windows 7 X64 Ultimate is BSODing occasionally. I suspect an overheating issue or something related to the use of my GTX-295 card that runs very hot. Here is an !analyze -v listing of the most recent minidump. Any and all help greatly appreciated. Kurt Microsoft (R) Windows Debugger Version 6.12.0002.633 AMD64 Copyright (c) Microsoft Corporation. All rights reserved. Loading Dump File [C:\Windows\Minidump\122810-31387-01.dmp] Mini Kernel Dump File: Only registers and stack trace are available Symbol search path is: SRV*c:\websymbols*http://msdl.microsoft.com/download/symbols Executable search path is: Windows 7 Kernel Version 7600 MP (8 procs) Free x64 Product: WinNt, suite: TerminalServer SingleUserTS Built by: 7600.16617.amd64fre.win7_gdr.100618-1621 Machine Name: Kernel base = 0xfffff800`03065000 PsLoadedModuleList = 0xfffff800`032a2e50 Debug session time: Tue Dec 28 11:04:03.597 2010 (UTC - 7:00) System Uptime: 2 days 2:28:40.407 Loading Kernel Symbols ............................................................... ................................................................ .............................................. Loading User Symbols Loading unloaded module list ................ ******************************************************************************* * * * Bugcheck Analysis * * * ******************************************************************************* Use !analyze -v to get detailed debugging information. BugCheck 3B, {c0000005, fffff800033b8873, fffff8800e322dc0, 0} Probably caused by : ntkrnlmp.exe ( nt!RtlCompareUnicodeStrings+c3 ) Followup: MachineOwner --------- 1: kd> !analyze -v ******************************************************************************* * * * Bugcheck Analysis * * * ******************************************************************************* SYSTEM_SERVICE_EXCEPTION (3b) An exception happened while executing a system service routine. Arguments: Arg1: 00000000c0000005, Exception code that caused the bugcheck Arg2: fffff800033b8873, Address of the instruction which caused the bugcheck Arg3: fffff8800e322dc0, Address of the context record for the exception that caused the bugcheck Arg4: 0000000000000000, zero. Debugging Details: ------------------ EXCEPTION_CODE: (NTSTATUS) 0xc0000005 - The instruction at 0x%08lx referenced memory at 0x%08lx. The memory could not be %s. FAULTING_IP: nt!RtlCompareUnicodeStrings+c3 fffff800`033b8873 488b7c2418 mov rdi,qword ptr [rsp+18h] CONTEXT: fffff8800e322dc0 -- (.cxr 0xfffff8800e322dc0) rax=0000000000000041 rbx=fffff8a015a3c1c0 rcx=0000000000000024 rdx=0000000000000003 rsi=fffff8800e3238b0 rdi=0000000000000009 rip=fffff800033b8873 rsp=fffff8800e323798 rbp=000000000000000d r8=fffff8a018cb374c r9=000000200a98fdc4 r10=fffff8800e323988 r11=fffff8800e32398e r12=fffff8a018127c18 r13=fffff8800126e550 r14=0000000000000001 r15=fffffa800abe1570 iopl=0 nv up ei pl nz ac po nc cs=0010 ss=0018 ds=002b es=002b fs=0053 gs=002b efl=00010216 nt!RtlCompareUnicodeStrings+0xc3: fffff800`033b8873 488b7c2418 mov rdi,qword ptr [rsp+18h] ss:0018:fffff880`0e3237b0=???????????????? Resetting default scope CUSTOMER_CRASH_COUNT: 1 DEFAULT_BUCKET_ID: VISTA_DRIVER_FAULT BUGCHECK_STR: 0x3B PROCESS_NAME: ccSvcHst.exe CURRENT_IRQL: 0 LAST_CONTROL_TRANSFER: from 0000000000000000 to fffff800033b8873 STACK_TEXT: fffff880`0e323798 00000000`00000000 : 00000000`00000000 00000000`00000000 00000000`00000000 00000000`00000000 : nt!RtlCompareUnicodeStrings+0xc3 FOLLOWUP_IP: nt!RtlCompareUnicodeStrings+c3 fffff800`033b8873 488b7c2418 mov rdi,qword ptr [rsp+18h] SYMBOL_STACK_INDEX: 0 SYMBOL_NAME: nt!RtlCompareUnicodeStrings+c3 FOLLOWUP_NAME: MachineOwner MODULE_NAME: nt IMAGE_NAME: ntkrnlmp.exe DEBUG_FLR_IMAGE_TIMESTAMP: 4c1c44a9 STACK_COMMAND: .cxr 0xfffff8800e322dc0 ; kb FAILURE_BUCKET_ID: X64_0x3B_nt!RtlCompareUnicodeStrings+c3 BUCKET_ID: X64_0x3B_nt!RtlCompareUnicodeStrings+c3 Followup: MachineOwner ---------

    Read the article

  • Windows 7 x64 "upgrade" repair fails

    - by Polynomial
    I've been running into issues with Windows Update, which I can't seem to fix. The hotfixes don't work, nor does the Windows update readyness tool, or the manual SP1 upgrade. I get various esoteric errors which nobody seems to have a fix for. Looks like some of the update cache is corrupt and digital signatures seem to be broken on some packages / Windows Update components. Long story short, I have discovered the only option is to do a repair operation on the OS, to repair everything. It's so corrupt that only a complete replacement will fix it. According to various sources (including MSKB) one can perform a repair by running an in-place upgrade. I've got the Windows 7 Ultimate retail disc, which I've inserted into my machine. I ran setup.exe and went through in the following order: Install now Go online to get latest updates (I've also tried not getting updates) Wait for updates to be downloaded Select Windows 7 Ultimate (x64 architecture) and click next Accept the T&Cs, click next Click Upgrade At this point it spends a minute on the "checking compatibility" screen, after which I get the following error: The following issues are preventing Windows from upgrading. Cancel the upgrade, complete each task, and then restart the upgrade to continue. You can’t upgrade 64-bit Windows to a 32-bit version of Windows. To upgrade, obtain a 64-bit version of the installation disc, or go online to see how to install Windows 7 and keep your files and settings. 32-bit Windows cannot be upgraded to a 64-bit version of Windows. To upgrade, obtain a 32-bit version of the Windows installation disc. It also mentions a warning about potential conflicts with a storage driver and VS2010, but that doesn't seem to be the blocking issue. My currently installed version of Windows is Ultimate 64-bit (absolutely sure of this) and the disc is definitely a x86 / x64 combined Ultimate retail disc. There seem to be a few people who have run into this (e.g. this question), but I've not seen any answers. I've checked the event viewer, but can't spot anything in there that's related. Any idea how I can get this working? P.S: Just to pre-empt the inevitable "are you suuuuuuuuuuuuure it's x64 Ultimate?" questions:

    Read the article

  • Debian Lenny syslog kernel messages

    - by andre
    Hello everyone. I've recently got a disk swap on my colo'd box. I've been getting these messages from the kernel (viewed on the terminal and later on /var/log/messages Mar 22 09:04:29 seedbox kernel: [72710.442831] Pid: 6527, comm: sshd Not tainted 2.6.26-2-amd64 #1 Mar 22 09:04:29 seedbox kernel: [72710.442831] RIP: 0010:[<ffffffff802876b9>] [<ffffffff802876b9>] page_remove_rmap+0xff/0x11a Mar 22 09:04:29 seedbox kernel: [72710.442831] RSP: 0018:ffff8100b75d1da8 EFLAGS: 00010246 Mar 22 09:04:29 seedbox kernel: [72710.442831] RAX: 0000000000000000 RBX: ffffe2000185e3e8 RCX: 0000000000008e53 Mar 22 09:04:29 seedbox kernel: [72710.442831] RDX: ffff810080a4c000 RSI: 0000000000000046 RDI: 0000000000000282 Mar 22 09:04:29 seedbox kernel: [72710.442831] RBP: ffff8100379838c8 R08: 00007f6d11ba4000 R09: ffff8100b75d1800 Mar 22 09:04:29 seedbox kernel: [72710.442831] R10: 0000000000000000 R11: 0000010000000010 R12: ffff8100bb446b00 Mar 22 09:04:29 seedbox kernel: [72710.442831] R13: 00007f6d11ba4000 R14: ffffe2000185e3e8 R15: ffff810001023b80 Mar 22 09:04:29 seedbox kernel: [72710.442831] FS: 0000000000000000(0000) GS:ffffffff8053d000(0000) knlGS:0000000000000000 Mar 22 09:04:29 seedbox kernel: [72710.442831] CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033 Mar 22 09:04:29 seedbox kernel: [72710.442831] CR2: 00007f6d1195b480 CR3: 0000000037904000 CR4: 00000000000006e0 Mar 22 09:04:29 seedbox kernel: [72710.442831] DR0: 0000000000000000 DR1: 0000000000000000 DR2: 0000000000000000 Mar 22 09:04:29 seedbox kernel: [72710.442831] DR3: 0000000000000000 DR6: 00000000ffff0ff0 DR7: 0000000000000400 Mar 22 09:04:29 seedbox kernel: [72710.442831] Process sshd (pid: 6527, threadinfo ffff8100b75d0000, task ffff8100bd0a0990) Mar 22 09:04:29 seedbox kernel: [72710.442831] Stack: 800000006f65b045 800000006f65b045 ffff8100bc013d20 ffffffff8027f69a Mar 22 09:04:29 seedbox kernel: [72710.442831] ffff810100000000 0000000000000000 ffff8100b75d1eb8 ffffffffffffffff Mar 22 09:04:29 seedbox kernel: [72710.442831] 0000000000000000 ffff8100379838c8 ffff8100b75d1ec0 0000000000296460 Mar 22 09:04:29 seedbox kernel: [72710.442831] Call Trace: Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff8027f69a>] ? unmap_vmas+0x4c9/0x885 Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff80283ac8>] ? exit_mmap+0x7c/0xf0 Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff80232538>] ? mmput+0x2c/0xa2 Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff802378ad>] ? do_exit+0x25a/0x6a6 Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff802afa45>] ? mntput_no_expire+0x20/0x117 Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff80237d66>] ? do_group_exit+0x6d/0x9d Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff80237da8>] ? sys_exit_group+0x12/0x16 Mar 22 09:04:29 seedbox kernel: [72710.442831] [<ffffffff8020beda>] ? system_call_after_swapgs+0x8a/0x8f Mar 22 09:04:29 seedbox kernel: [72710.442831] Mar 22 09:04:29 seedbox kernel: [72710.442831] Mar 22 09:04:29 seedbox kernel: [72710.442831] RSP <ffff8100b75d1da8> Mar 22 09:04:29 seedbox kernel: [72710.442831] ---[ end trace e8a2f3b263482c6e ]--- I don't know what the problem is or how to debug / track it, hope you guys can help.. let me know if you need more information.

    Read the article

  • Blank Page: wordpress on nginx+php-fpm

    - by troutwine
    Good day. While this post discusses a similar setup to mine serving blank pages occasionally after having made a successful installation, I am unable to serve anything but blank pages. My setup: Wordpress 3.0.4 nginx 0.8.54 php-fpm 5.3.5 (fpm-fcgi) Arch Linux Configuration Files php-fpm.conf: [global] pid = run/php-fpm/php-fpm.pid error_log = log/php-fpm.log log_level = notice [www] listen = 127.0.0.1:9000 listen.owner = www listen.group = www listen.mode = 0660 user = www group = www pm = dynamic pm.max_children = 50 pm.start_servers = 20 pm.min_spare_servers = 5 pm.max_spare_servers = 35 pm.max_requests = 500 nginx.conf: user www; worker_processes 1; error_log /var/log/nginx/error.log notice; pid /var/run/nginx.pid; events { worker_connections 1024; } http { include mime.types; default_type application/octet-stream; sendfile on; keepalive_timeout 65; gzip on; include /etc/nginx/sites-enabled/*.conf; } /etc/nginx/sites-enabled/blog_sharonrhodes_us.conf: upstream php { server 127.0.0.1:9000; } server { error_log /var/log/nginx/us/sharonrhodes/blog/error.log notice; access_log /var/log/nginx/us/sharonrhodes/blog/access.log; server_name blog.sharonrhodes.us; root /srv/apps/us/sharonrhodes/blog; index index.php; location = /favicon.ico { log_not_found off; access_log off; } location = /robots.txt { allow all; log_not_found off; access_log off; } location / { # This is cool because no php is touched for static content try_files $uri $uri/ /index.php?q=$uri&$args; } location ~ \.php$ { fastcgi_split_path_info ^(.+\.php)(/.+)$; #NOTE: You should have "cgi.fix_pathinfo = 0;" in php.ini include fastcgi_params; fastcgi_intercept_errors on; fastcgi_pass php; } location ~* \.(js|css|png|jpg|jpeg|gif|ico)$ { expires max; log_not_found off; } }

    Read the article

  • DNS entries for OCS 2007 R2 basic deploy

    - by Anero
    I'm doing a test deploy on a Lab with 3 VMs: TEST-DC: DC / DHCP / DNS / Root CA (Joined to TEST.AD Domain) TEST-CS: OCS Front End (Joined to TEST.AD Domain - IP: 10.0.128.1) TEST-EDGES: OCS Edge Server (Joined to Workgroup: EDGE-WKG - Internal IP: 10.0.128.3, External IPs: 192.168.129.12 - Access Edge Server, 192.168.129.13 - Web Conferencing, 192.168.129.14 - A/V) I can login with the Communicator Client from within computers in the domain (using [email protected]) and even the Automatic Sign-In works as expected. Nevertheless, I cannot login neither from within machines in the domain nor from outside the domain using [email protected]. I'm pretty sure it is a DNS related issue, so I'm including below a list of the entries. DNS Entries on TEST-DC: Forward Lookup Zones TEST.AD sip.test.ad (Host A). IP Address: 10.0.128.1 sipinternal.test.ad (Host A). IP Address: 10.0.128.1 sipexternal.test.ad (Host A). IP Address: 10.0.128.3 _sipinternaltls._tcp.test.ad (Service Location SRV). Port: 5061. Host: sipinternal.test.ad _sipinternal._tcp.test.ad (Service Location SRV). Port: 5061. Host: sipinternal.test.ad _sip._tcp.test.ad (Service Location SRV). Port: 5061. Host: sipexternal.test.ad _sipfederationtls._tcp.test.ad (Service Location SRV). Port: 5061. Host: sipexternal.test.ad _sip._tls.test.ad (Service Location SRV). Port: 443. Host: sipexternal.test.ad TEST.COM sip.test.com (Host A). IP Address: 10.0.128.1 sipinternal.test.com (Host A). IP Address: 10.0.128.1 sipexternal.test.com (Host A). IP Address: 10.0.128.3 _sipinternaltls._tcp.test.com (Service Location SRV). Port: 5061. Host: sipinternal.test.com _sipinternal._tcp.test.com (Service Location SRV). Port: 5061. Host: sipinternal.test.com _sip._tcp.test.com (Service Location SRV). Port: 5061. Host: sipexternal.test.com _sip._tls.test.ad (Service Location SRV). Port: 443. Host: sipexternal.test.ad Validation Errors OCS Front End Edge Server I ran the OCS 2007 Automatic Sign-In Troubleshooting and all DNS entries for both TEST.AD and TEST.COM are reported to be OK. What am I missing?

    Read the article

  • How to make Linux reliably boot on multi-cpu machines?

    - by Adam Tabi
    I've got two machines, one with 4x12 AMD Opteron cores (AMD Opteron(tm) Processor 6176), one with 2x8 Xeon cores (HT disabled; Intel(R) Xeon(R) CPU E5-2660 0 @ 2.20GHz). On both machines I experience difficulties during boot of Linux using recent kernels. The system hangs during the initialization of the kernel, before or just when initramfs started initializing the hardware. The last thing which got displayed was a stacktrace like this: CPU: 31 PID: 0 Comm: swapper/31 Tainted: G D 3.11.6-hardened #11 Hardware name: Supermicro X9DRT-HF+/X9DRT-HF+, BIOS 3.00 07/08/2013 task: ffff880854695500 ti: ffff880854695a28 task.ti: ffff880854695a28 RIP: 0010:[<ffffffff8100a82e>] [<ffffffff8100a82e>] default_idle+0x6/0xe RSP: 0000:ffff8808546b3ec8 EFLAGS: 00000286 RAX: ffffffff8100a828 RBX: ffff880854695a28 RCX: 00000000ffffffff RDX: 0100000000000000 RSI: 0000000000000000 RDI: ffff88107fdec690 RBP: ffff8808546b3ec8 R08: 0000000000000000 R09: ffff880854695500 R10: ffff880854695500 R11: 0000000000000001 R12: ffff880854695a28 R13: ffff880854695a28 R14: ffff880854695a28 R15: 0000000000000000 FS: 0000000000000000(0000) GS:ffff88107fde0000(0000) knlGS:0000000000000000 CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033 CR2: 000002b43256a960 CR3: 00000000016b5000 CR4: 00000000000607f0 Stack: ffff8808546b3ed8 ffffffff8100aec9 ffff8808546b3f10 ffffffff8109ce25 334ab55852ec7aef 000000000000001f ffffffff8102d6c0 0000000000000000 0000000000000000 ffff8808546b3f48 ffffffff810276e0 ffff8808546b3f28 Call Trace: [<ffffffff8100aec9>] arch_cpu_idle+0x20/0x2b [<ffffffff8109ce25>] cpu_startup_entry+0xed/0x138 [<ffffffff8102d6c0>] ? flat_init_apic_ldr+0x80/0x80 [<ffffffff810276e0>] start_secondary+0x2c9/0x2f8 I compiled the kernel myself and it works fine, if I boot with nolapic. Yet, only one core is used. Also, the kernel of RHEL6 seems to work fine. I suspect that there are some patches used to make things work. Using the kernel config file from RHEL6 and building a more recent kernel yields the same problems. On the Xeon machine, things got better by disabling Hyperthreading completely. The machine now boots successfully on at least 4 out of 5 times. And if it boots, multicore stuff works just fine. However, I'm wondering about what to do about the AMD machine. So to sum it up: Gentoo kernel 3.6 - 3.11 won't reliably boot those machines unless you reduce the amount of cores (e.g. via nolapic). RHEL6 kernel (which is 2.6.32) boots just fine. RH kernel config used to build a 3.x kernel won't yield a working kernel. Not distribution specific (apart from the kernel being used). These stack traces got printed every minute or so. The kernel seems to be stuck in an endless loop. Yet, a recent kernel is needed for various reasons. So the question is: What does the RHEL6 kernel do, what vanilla or gentoo kernels don't do? Is there a boot option that might lead to a reliable boot with all the cores enabled? Best, Adam

    Read the article

  • Apache and MySQL taking all the memory? Maximum connections?

    - by lpfavreau
    I've a had one of our servers going down (network wise) but keeping its uptime (so looks the server is not losing its power) recently. I've asked my hosting company to investigate and I've been told, after investigation, that Apache and MySQL were at all time using 80% of the memory and peaking at 95% and that I might be needing to add some more RAM to the server. One of their justifications to adding more RAM was that I was using the default max connections setting (125 for MySQL and 150 for Apache) and that for handling those 150 simultaneous connections, I would need at least 3Gb of memory instead of the 1Gb I have at the moment. Now, I understand that tweaking the max connections might be better than me leaving the default setting although I didn't feel it was a concern at the moment, having had servers with the same configuration handle more traffic than the current 1 or 2 visitors before the lunch, telling myself I'd tweak it depending on the visits pattern later. I've also always known Apache was more memory hungry under default settings than its competitor such as nginx and lighttpd. Nonetheless, looking at the stats of my machine, I'm trying to see how my hosting company got those numbers. I'm getting: # free -m total used free shared buffers cached Mem: 1000 944 56 0 148 725 -/+ buffers/cache: 71 929 Swap: 1953 0 1953 Which I guess means that yes, the server is reserving around 95% of its memory at the moment but I also thought it meant that only 71 out of the 1000 total were really used by the applications at the moment looking a the buffers/cache row. Also I don't see any swapping: # vmstat 60 procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 0 57612 151704 742596 0 0 1 1 3 11 0 0 100 0 0 0 0 57604 151704 742596 0 0 0 1 1 24 0 0 100 0 0 0 0 57604 151704 742596 0 0 0 2 1 18 0 0 100 0 0 0 0 57604 151704 742596 0 0 0 0 1 13 0 0 100 0 And finally, while requesting a page: top - 08:33:19 up 3 days, 13:11, 2 users, load average: 0.06, 0.02, 0.00 Tasks: 81 total, 1 running, 80 sleeping, 0 stopped, 0 zombie Cpu(s): 1.3%us, 0.3%sy, 0.0%ni, 98.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 1024616k total, 976744k used, 47872k free, 151716k buffers Swap: 2000052k total, 0k used, 2000052k free, 742596k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 24914 www-data 20 0 26296 8640 3724 S 2 0.8 0:00.06 apache2 23785 mysql 20 0 125m 18m 5268 S 1 1.9 0:04.54 mysqld 24491 www-data 20 0 25828 7488 3180 S 1 0.7 0:00.02 apache2 1 root 20 0 2844 1688 544 S 0 0.2 0:01.30 init ... So, I'd like to know, experts of serverfault: Do I really need more RAM at the moment? How do they calculate that for 150 simultaneous connections I'd need 3Gb? Thanks for your help!

    Read the article

  • Brand new Mac Pro tower fan suddenly runs full-tilt

    - by Caffeine Coma
    My Quad-Core Mac Pro tower is two days old. Initially, I was impressed with how quiet it was compared to my older Macbook Pro. Then on day two, for some reason it started running very loudly. It's not just a "little" loud- my wife walked into the room and asked what the noise was. At first I thought this was just because I was hitting the CPU a bit (importing my iPhone library into iLife '09, and running Eclipse). But now that that's done, Activity Monitor shows a virtually idle CPU; there's nothing running that ought to be causing this, as far as I can tell. I tried powering it off & letting it cool down for a few minutes to no avail; about 10 seconds after powering up, the box gets loud again. I took a look at it with the side cover off, and it seems to be the fan near the top middle, between the power supply and the disk drive. It can't be a dust issue, as the machine is only 2 days old (and I peeked inside anyway just to be sure- clean). I did do a software update over the past 24 hours or so, but I can't say that it occurred immediately after that. I also did a migration of my old apps and data from my MBPro, for what it's worth. Why is it suddenly so loud? How can I monitor the fan speed and various system temperatures? Here's a link to my temps and fan speeds. UPDATE 1: Took it to the Apple Store. They took it in the back (where it's presumably quieter) and ran a fan diagnostic; no problems were found. The guy also told me that it was "a little loud", but normal. I don't buy it. It was virtually silent the first 24 hours I was using it. They would not replace/service it in the store (grrr... that's why I went there, as directed by Apple Care) but said I could get a replacement from the online store, as it was just purchased. I think I will try that. UPDATE 2: Apple is letting me send it back for a replacement. Glad to see so many responses to this question mentioning that the MacPros are usually silent; it's not all just in my head. :-)

    Read the article

  • Installing the Newest KeePass for MacOSX from Source

    - by firebush
    I've transitioned our passwords to KeePass. LastPass looks cool, but I prefer a system where we control the database locally rather than it being kept in the cloud. I have a windows and Linux system and both are able to access our KeePass database easily. On my Linux system (Ubuntu), I simply installed KeePass via synaptic and it just worked. So everything was working great, until my wife tried to set up things on her MacBook to access the database. Huge problems. It was so easy on Linux that I didn't expect there to be issues there. In case it's helpful, she's running a fresh install of Mac OSX 10.5.8, Leopard. We simply went to the download site for KeePass: http://keepass.info/download.html Clicked on the link titled KeePass 2.x for Mac OS X from which we retrieved Mono 2.10.5 and KeePass 2.18 from that site (the packages posted there at the time of this writing). Mono installed without problems (at least, none that we saw). She opened the KeePass image and dragged it to the Application side, unpackaging it there. According to the instructions on the KeePass installation instructions, she opened a terminal, changed to the directory in /Applications containing KeePass.exe, and ran it through mono: mono KeePass.exe No application opens at all - we see a blip for it, but then it immediately goes away, indicating to us that it is crashing. Also disconcerting, I see that people are throwing fits about copy-and-paste not working for KeePass 2.18 on MacOSX. Judging from the 2.19 addresses the copy/paste issue. I'm hoping that version will solve all our issues. So here's my question: how can I try out 2.19 on her system. It doesn't seem to be packaged like the 2.18 one is. But we're not scared of building it. I see that the source for 2.19 is here (at the bottom of the page). Can I just download that to her machine somewhere and run something to build it? I'm familiar with automake but not with building .NET source, so please answer gently if this is stupidly easy. :^) btw: tomorrow's my wife's birthday, and this is getting her down. If you know how to navigate these issues, it would be a nice birthday gift for her. Thanks in advance! Update I'll post this since it might be helpful to someone else: I got KeePass 2.18 to run by updating Mono to 2.10.9 (rather than the 2.10.5 given by the site above). With the later version of Mono, it runs without crashing. And yet, I do see the copy and paste issue that others see. I can open a database on her machine, but the incorrect data get's copied. So again, can someone help me install KeePass 2.19? Thanks!

    Read the article

  • CPU overheating after cleaning it

    - by Roberts
    I wanted to clean my computer CPU heatsink and fan itself, because the temperature is not what I wanted. About (50C ~ 70C). I have Intel Core 2 Duo E4300 @1.8 GHz (LGA775). The heatsink wasn't so scary filled with dust but I wanted to clean it anyway. I didn't know how to get heatsink with fan from the socket. So after 25 minutes I've figured it out. But I didn't know how to get it back on so I spent a lot time getting out the motherboard from the case. The fan and heatsink... The case and all components are clear of dust. (I'm tired now). Then I put all back just the way it was, well did few things on cable management. But the problem was that I didn't know how to connect front audio connectors. I had Windows XP hibernated. So I started the PC and everything was normal, except CMOS memory was clear. I configured the BIOS just the way it was and while I was doing that I saw about 58C CPU temperature and fan at 1789 RPM. Restarted the computer with new settings applied. But Windows halted with Blue Screen (I forgot what error it was but something with KERNEL). Restarted the PC and deleted hibernation session and everything was back normal. But couldn't record any sound from front panel microphone. The problem was that I messed ground wire with mic. Again after fixing it I turned computer on. No problems. The fan currently is noisy and temperature was 78C. The temperature before was 55C - 60C at idle. Now it's about 60C. If I do something then temperature raises to 79C. While speaking in skype the temperature was 82C. Could this problem occur because of the thermal grease (it's old and never replaced)? Edit The problem wasn't in thermal paste (because I didn't touch it). The problem was that I installed heatsink wrong. Now instead of regular 60C CPU temperature the CPU is at 48C (cool).

    Read the article

  • Disk IO causing high load on Xen/CentOS guest

    - by Peter Lindqvist
    I'm having serious issues with a xen based server, this is on the guest partition. It's a paravirtualized CentOS 5.5. The following numbers are taken from top while copying a large file over the network. If i copy the file another time the speed decreases in relation to load average. So the second time it's half the speed of the first time. It needs some time to cool off after this. Load average slowly decreases until it's once again usable. ls / takes about 30 seconds. top - 13:26:44 up 13 days, 21:44, 2 users, load average: 7.03, 5.08, 3.15 Tasks: 134 total, 2 running, 132 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.1%sy, 0.0%ni, 25.3%id, 74.5%wa, 0.0%hi, 0.0%si, 0.1%st Mem: 1048752k total, 1041460k used, 7292k free, 3116k buffers Swap: 2129912k total, 40k used, 2129872k free, 904740k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 1506 root 10 -5 0 0 0 S 0.3 0.0 0:03.94 cifsd 1 root 15 0 2172 644 556 S 0.0 0.1 0:00.08 init Meanwhile the host is ~0.5 load avg and steady over time. ~50% wait Server hardware is dual xeon, 3gb ram, 170gb scsi 320 10k rpm, and shouldn't have any problems with copying files over the network. disk = [ "tap:aio:/vm/dev01.img,xvda,w" ] I also get these in the log INFO: task syslogd:1350 blocked for more than 120 seconds. "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. syslogd D 00062E4F 2208 1350 1 1353 1312 (NOTLB) c0ef0ed0 00000286 6e71a411 00062e4f c0ef0f18 00000009 c0f20000 6e738bfd 00062e4f 0001e7ec c0f2010c c181a724 c1abd200 00000000 ffffffff c0ef0ecc c041a180 00000000 c0ef0ed8 c03d6a50 00000000 00000000 c03d6a00 00000000 Call Trace: [<c041a180>] __wake_up+0x2a/0x3d [<ee06a1ea>] log_wait_commit+0x80/0xc7 [jbd] [<c043128b>] autoremove_wake_function+0x0/0x2d [<ee065661>] journal_stop+0x195/0x1ba [jbd] [<c0490a32>] __writeback_single_inode+0x1a3/0x2af [<c04568ea>] do_writepages+0x2b/0x32 [<c045239b>] __filemap_fdatawrite_range+0x66/0x72 [<c04910ce>] sync_inode+0x19/0x24 [<ee09b007>] ext3_sync_file+0xaf/0xc4 [ext3] [<c047426f>] do_fsync+0x41/0x83 [<c04742ce>] __do_fsync+0x1d/0x2b [<c0405413>] syscall_call+0x7/0xb ======================= I have tried disabling irqbalanced as suggested here but it does not seem to make any difference.

    Read the article

  • Connecting multiple ColdFusion 10 instances to a single Apache 2.2 server

    - by Adam Cameron
    This is on Windows 7 Home Premium edition. I have got two ColdFusion 10 (updater 2) instances: "cfusion" (the default one), and "scratch". I have got a single instance of Apache 2.2 running. Within Apache, I have set up two virtual hosts, each of which needs to be served by a different ColdFusion instance. Each of the CF instances serves files fine via Tomcat's internal web server. Apache serves vanilla HTML files fine too. So both CF instances, and both virtual hosts separately work OK. I can get wsconfig.exe to connect either one of the CF instances to the Apache server, and serve CF files via Apache & that instance. However I cannot find a way of connecting the second CF instance to Apache as well, so that both CF instances are conected, each serving one of the virtual hosts. WSConfig doesn't seem to understand the notion of "multiple CF instances", and the changes it makes to the httpd.conf (via mod_jk.conf) does not seem to be implemented in such a way as to accommodate multiple CF instances talking to a single Apache instance, or multiple virtual hosts. I freely admit to not being confident enough with how mod_jk (or even really httpd.conf) works to be able to guess if I can change stuff to make it work. If I try to add the second CF instance using WSConfig, I just get a message "the web server is already configured for ColdFusion". Be that as it may... not the instance of ColdFusion I want to connect it to! If I remove the existing connector to whichever instance is already connected, I can then connect the other one no problems. Not that this helps, but it demonstrates that the CF instance can connect to Apache. This all used to be fairly straight fwd under older versions of CF and JRun :-( The only docs I have found are on the "Connect multiple Apache virtual hosts on a web server to a single ColdFusion server" page, but that specifically only deals with a single CF instance. There is no equivalent page for multiple CF instances. I'm kinda hoping I can move some of the mod_jk config into my virtual host entries in httpd-vhosts.conf (this is how it used to work for JRun), but I've no idea what to put where. I think I've covered all the necessary info here? If not, sing out and I'll add more. Thanks. PS: tried to specifically tag this as "ColdFusion-10" as the answer will be different from previous CF versions, but it won't let me cos my rep on this site is too low (odd how it doesn't consider my rep from other S/O sites...). If someone with sufficient rep can add it, that'd be cool: it's probably a valid tag to have. Ta.

    Read the article

  • configuring slime in emacs

    - by CodeKingPlusPlus
    I am in the process of configuring slime for emacs. So far I have read about basic functionality for common lisp such as C-c C-q which invokes the command slime-close-parens-at-point which places the proper number of parens where your mouse is. Another command that seemed cool was invoked by C-c C-c and it would pass the code you are editing in a buffer to the REPL, and "compile" it. Why won't these commands work for me? Anyway, I have downloaded slime via M-x list-packages and do not seem to have this functionality (C-h w and then any of these commands tells me that these commands do note exist). So, I saw a bunch of other slime extensions such as slime-repl', 'slime-fuzzy' and 'hippie-expand-slime'. So I again usedM-x list-packages` and downloaded them. Still I did not have these commands. Here is the content of my emacs file relevant to slime: ;;;Common Lisp and Slime (add-to-list 'load-path "/home/s2s2/.emacs.d/elpa/slime-20130626.1151") (add-to-list 'load-path "/home/s2s2/.emacs.d/elpa/slime-repl-201000404") (add-to-list 'load-path "/home/s2s2/.emacs.d/elpa/hippie-expand-slime-20130226.1656") (add-to-list 'load-path "/home/s2s2/.emacs.d/elpa/slime-fuzzy-20100404") (require 'slime) (setq slime-lisp-implementations `((sbcl ("/usr/bin/sbcl")) (ecl ("/usr/bin/ecl")) (clisp ("/usr/bin/clisp" "-q -I")))) (require 'slime-repl) (require 'slime-fuzzy) (require 'hippie-expand-slime) When I execute M-x slime I get the following message in the inferior-lisp buffer where I can execute common lisp code (however, shouldn't this be the slime-repl since I required it?): STYLE-WARNING: redefining EMACS-INSPECT (#<BUILT-IN-CLASS T>) in DEFMETHOD STYLE-WARNING: Implicitly creating new generic function STREAM-READ-CHAR-WILL-HANG-P. WARNING: These Swank interfaces are unimplemented: (DISASSEMBLE-FRAME SLDB-BREAK-AT-START SLDB-BREAK-ON-RETURN) ;; Swank started at port: 46533. Then a slime-error buffer is created with the contents: Invalid protocol message: Symbol "CREATE-REPL" not found in the SWANK package. Line: 1, Column: 28, File-Position: 28 Stream: #<SB-IMPL::STRING-INPUT-STREAM {10056B9C33}> (:emacs-rex (swank:create-repl nil) "COMMON-LISP-USER" t 5) How should I modify my emacs file to give me the functionality of those commands? In my emacs file am I not loading the necessary files? Do I need to install an additional package? If you need more information let me know! All help is much appreciated!

    Read the article

  • Ubuntu Server 12.04 CPU Load

    - by zertux
    I have a Server (2x Hexa-Core Xeon E5649 2.53GHz w/HT with 32GB RAM and 20000 GB Bandwidth) running Ubuntu Server 12.04 LTS. The server runs LAMP and serves one website only, the estimated number of users is to be ~ 15,000 at the same time. At the moment i have around 2000 users online each of them runs 50 MySQL queries (small values mostly select and insert) from the beginning until the end of the session. Server CPU Load is high at this number of connections while the RAM usage is almost 1GB out of 32GB its worth mentioning that the server was running very fast with no problems at all but am concerned about the load average. http://s12.postimage.org/z7hi6mz3h/photo.png top - 03:02:43 up 9 min, 2 users, load average: 50.83, 30.14, 12.83 Tasks: 432 total, 1 running, 430 sleeping, 0 stopped, 1 zombie Cpu(s): 0.1%us, 0.2%sy, 0.0%ni, 66.5%id, 33.1%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 32939992k total, 3111604k used, 29828388k free, 84108k buffers Swap: 2048280k total, 0k used, 2048280k free, 1621640k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 2860 root 20 0 25820 2288 1420 S 3 0.0 0:11.18 htop 1182 root 20 0 0 0 0 D 2 0.0 0:01.46 kjournald 1935 mysql 20 0 12.3g 161m 7924 S 1 0.5 102:31.45 mysqld 11 root 20 0 0 0 0 S 0 0.0 0:00.38 kworker/0:1 1822 www-data 20 0 247m 25m 4188 D 0 0.1 0:01.81 apache2 2920 www-data 20 0 0 0 0 Z 0 0.0 0:01.20 apache2 <defunct> 2942 www-data 20 0 247m 23m 3056 D 0 0.1 0:00.20 apache2 3516 www-data 20 0 247m 23m 3028 D 0 0.1 0:00.06 apache2 3521 www-data 20 0 247m 23m 3020 D 0 0.1 0:00.09 apache2 3664 www-data 20 0 247m 23m 3132 D 0 0.1 0:00.09 apache2 3674 www-data 20 0 247m 23m 3252 D 0 0.1 0:00.06 apache2 3713 www-data 20 0 247m 23m 3040 D 0 0.1 0:00.09 apache2 1 root 20 0 24328 2284 1344 S 0 0.0 0:03.09 init 2 root 20 0 0 0 0 S 0 0.0 0:00.00 kthreadd 3 root 20 0 0 0 0 S 0 0.0 0:00.01 ksoftirqd/0 6 root RT 0 0 0 0 S 0 0.0 0:00.00 migration/0 7 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/0 8 root RT 0 0 0 0 S 0 0.0 0:00.00 migration/1 9 root 20 0 0 0 0 S 0 0.0 0:00.00 kworker/1:0 root@server:~/codes# vmstat 1 procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 19 0 0 29684012 86112 1689844 0 0 19 590 254 231 48 0 47 5 23 0 0 29704812 86128 1697672 0 0 4 320 11100 8121 77 1 22 0 33 0 0 29671044 86156 1705308 0 0 0 5440 13190 9140 95 1 4 0 33 3 0 29670088 86160 1706288 0 0 0 32932 12275 7297 99 0 1 0 35 0 0 29693456 86188 1710724 0 0 4 676 12701 7867 98 1 1 0 ^C I have not changed any of the default configurations that comes with Ubuntu. Is this load normal for such powerful server ? is there any optimization i can make to Apache/MySQL to minimize the load ? What do you recommend ?

    Read the article

  • Is my Cisco switch port bad?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced last week, however the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link (switchport configuration pastebin). We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • CakePHP in a subdirectory using nginx (Rewrite rules?)

    - by lhnz
    I managed to get this to work a while back, but on returning to the cakephp project I had started it seems that whatever changes I've made to nginx recently (or perhaps a recent update) have broken my rewrite rules. Currently I have: worker_processes 1; events { worker_connections 1024; } http { include mime.types; default_type application/octet-stream; sendfile on; keepalive_timeout 65; server { listen 80; server_name localhost; location / { root html; index index.php index.html index.htm; } location /basic_cake/ { index index.php; if (-f $request_filename) { break; } if (!-f $request_filename) { rewrite ^/basic_cake/(.+)$ /basic_cake/index.php?url=$1 last; break; } } location /cake_test/ { index index.php; if (-f $request_filename) { break; } if (!-f $request_filename) { rewrite ^/cake_test/(.+)$ /cake_test/index.php?url=$1 last; break; } } # redirect server error pages to the static page /50x.html # error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } # pass the PHP scripts to FastCGI server listening on 127.0.0.1:9000 # location ~ \.php$ { root html; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; include fastcgi_params; } } server { listen 8081; server_name localhost; root /srv/http/html/xsp; location / { index index.html index.htm index.aspx default.aspx; } location ~ \.(aspx|asmx|ashx|asax|ascx|soap|rem|axd|cs|config|dll)$ { fastcgi_pass 127.0.0.1:9001; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; include fastcgi_params; } } } The problem that I have is that the css and images will not load from the webroot. Instead if I visit http://localhost/basic_cake/css/cake.generic.css, I get a page which tells me: CakePHP: the rapid development php framework Missing Controller Error: CssController could not be found. Error: Create the class CssController below in file: app/controllers/css_controller.php var $name = 'Css'; } ? Notice: If you want to customize this error message, create app/views/errors/missing_controller.ctp CakePHP: the rapid development php framework Does anybody have any ideas on how to fix this?

    Read the article

  • Dangers of Running Computers w/o Air Conditioning

    - by Daniel Bingham
    I recently moved in to an apartment with out air conditioning. This is fine most of the time as I am in upstate New York. It only ever gets above the high 70s during the hottest of the summer months. And when it does, I'm stubborn enough that I'll just deal with wearing minimal clothing around the house. However, I'm worried about my computers. I'm a software developer and gamer, so many of my machines are very high powered. And at least one of them is a server that must be left on 24/7 (not just a game server - also serves multiple websites). I've never before had to worry about the heat too much, as I always lived in buildings with central air. The in building temperature rarely got much above 70 F. All of the machines I built had good enough air cooling that I never saw a problem. Now the temperature in building is pushing 100F and I'm worried that the machines will not be able to keep themselves cool enough by simply blowing already hot air over themselves. The hottest of them I've turned off. However, the server I cannot. It's an old Dell (not custom build) that runs on a Pentium 4 (2.2GHz). It only has a single hard drive, integrated video. And it'd not running any processor intensive servers. Just basic LAMP. It used to run a MUD server, but that's off for now. So it should be idling most of the time. I haven't been able to find any sort of built in temperature sensors in the hardware... at least not any that the programs I've found in the Debian repository can read. And it's an inherited machine to which I do not have the full specs, so I don't know the tolerances anyway. How worried should I be about it melting down on me? How worried should I be about the hard drive melting or becoming corrupted? To generalize the question for other people, what are the safe temperature tolerances for most machines. How widely does it vary, and how does one go about determining when their machine is running too hot and needs to be shut down?

    Read the article

  • How to Setup Ubuntu Mail Server with Google Apps?

    - by Apreche
    I have a domain, let's call it foobar.com. All of the MX records for foobar.com point to Google's mail servers because I am using Google Apps for your domain to manage it. It's great because everyone gets all the advantages of GMail, but our e-mail addresses aren't @gmail.com. I also have a server. Primarily, it's a web server, but it also serves other things. One of the things it serves is the web site for foobar.com and also sites for various virtual hosts such as shop.foobar.com and forum.foobar.com. The server is running Ubuntu 8.04, because I like using LTS releases in production. The thing is, there are various applications running on the server that need the ability to send out emails. Various applications, like the cron jobs, send me e-mails in case of errors. Some of the web applications need to send e-mail to users when they forget their passwords, to confirm new registered users, etc. Lastly, it's nice to be able to send e-mail from the command line using the mail command, or mutt. How can I setup the mail on the web server to go through the Google apps mail servers? I don't need the web server to receive mail, though that would be cool. I do need it to be able to send mail as any legitimate address @foobar.com. That way the forum application can send mails with [email protected] in the from field, and the ecommerce application will have [email protected] in the from field. Also, by sending the mail through the Google servers, we can avoid a lot of the problems with the e-mails being blocked by various spam filters on the web. Google's SMTP servers are trusted a lot more than mine would be. I'm pretty good with administering Linux systems, but I am absolutely brain dead when it comes to e-mail. I need step by step directions from beginning to end on how to set this up. I need to know every thing to install, and every single change to the configuration files that is necessary. I have tried following various howtos and guides in the past, but none of them were quite right. Either they didn't work at all, or they offered a configuration that is not what I wanted. Please help. Thanks.

    Read the article

< Previous Page | 181 182 183 184 185 186 187 188 189 190 191 192  | Next Page >