Search Results

Search found 5237 results on 210 pages for 'dll unloading'.

Page 194/210 | < Previous Page | 190 191 192 193 194 195 196 197 198 199 200 201  | Next Page >

  • .Net Crystal Report printing application running on termianal service connection errors when session

    - by MrEdmundo
    I have created a .Net application to run on an App Server that gets requests for a report and prints out the requested report. The C# application uses Crystal Reports to load the report and subsequently print it out. The application is run on Server which is connected to via a Remote Desktop connection under a particular user account (required for old apps). When I disconnect from the Remote Session the application starts raising exceptions such as: Message: CrystalDecisions.Shared.CrystalReportsException: Load report failed This type of error is never raised when the Remote Session is active. The server running the app is running Windows Server 2003, my box which creates the connection is Windows XP. I appreciate this is fairly weird, however I cannot see any problem with the application deployment I have created. Does anyone know what could be cause this issue? EDIT: I bit the bullet and created the application as a windows service, obviously this doesn't take long I just wasn't convinced it would solve the problem. Anyway it doesn't!!! I have also tried removing the multi-thread code that was calling the print function asynchronously. I did this in order to simply the app and narrow down the reason it could fail. Anyway, this didn't improve the situation either! EDIT: The two errors I get are: System.Runtime.InteropServices.COMException (0x80000201): Invalid printer specified. at CrystalDecisions.ReportAppServer.Controllers.PrintOutputControllerClass.ModifyPrinterName(String newVal) at CrystalDecisions.CrystalReports.Engine.PrintOptions.set_PrinterName(String value) at Dsa.PrintServer.Service.Service.PrintCrystalReport(Report report) The printer isn't invalid, this is confirmed when 60 seconds later the time ticks and the report is printed successfully. And The request could not be submitted for background processing. at CrystalDecisions.ReportAppServer.Controllers.ReportSourceClass.GetLastPageNumber(RequestContext pRequestContext) at CrystalDecisions.ReportSource.EromReportSourceBase.GetLastPageNumber(ReportPageRequestContext reqContext) --- End of inner exception stack trace --- at CrystalDecisions.ReportAppServer.ConvertDotNetToErom.ThrowDotNetException(Exception e) at CrystalDecisions.ReportSource.EromReportSourceBase.GetLastPageNumber(ReportPageRequestContext reqContext) at CrystalDecisions.CrystalReports.Engine.FormatEngine.PrintToPrinter(Int32 nCopies, Boolean collated, Int32 startPageN, Int32 endPageN) at CrystalDecisions.CrystalReports.Engine.ReportDocument.PrintToPrinter(Int32 nCopies, Boolean collated, Int32 startPageN, Int32 endPageN) at Dsa.PrintServer.Service.Service.PrintCrystalReport(Report report) EDIT: I ran filemon to check if there were any access issue. At the point when the error occurs file mon reports Request: OPEN | Path: C:\windows\assembly\gac_msil\system\2.0.0.0__b77a5c561934e089\ws2_32.dll | Result: NOT FOUND | Other: Attributes Error

    Read the article

  • IdHttp Post Method Delphi 2010

    - by Dusten S
    Like others before me, I'm having troubles using the IdHttp(Indy 10.5.5) component in Delphi 2010. The code works fine in Delphi 7: var XMLString : AnsiString; lService : AnsiString; ResponseStream: TMemoryStream; InputStringList : TStringList; begin ResponseStream := TMemoryStream.Create; InputStringList := TStringList.Create; XMLString :='<?xml version="1.0" encoding="ISO-8859-1"?> '+ '<!DOCTYPE pnet_imessage_send PUBLIC "-//PeopleNet//pnet_imessage_send" "http://open.peoplenetonline.com/dtd/pnet_imessage_send.dtd"> '+ '<pnet_imessage_send> '+ ' <cid>username</cid> '+ ' <pw>password</pw> '+ ' <vehicle_number>tr01</vehicle_number> '+ ' <deliver>now</deliver> '+ ' <action> '+ ' <action_type>reply_with_freeform</action_type> '+ ' <urgent_reply>yes</urgent_reply> '+ ' </action> '+ ' <freeform_message>Test Message Version 2</freeform_message> '+ '</pnet_imessage_send> '; lService := 'imessage_send'; InputStringList.Values['service'] := lService; InputStringList.Values['xml'] := XMLString; try IdHttp1.Request.Accept := '*/*'; IdHttp1.Request.ContentType := 'text/XML'; IdHTTP1.Post('http://open.peoplenetonline.com/scripts/open.dll', InputStringList, ResponseStream); ... finally ResponseStream.Free; InputStringList.Free; end; The only differences so far between this and the D7 code is that I've changed the String types to AnsiString, and added the HTTP Request properties. The response I get back from the server is 'XML failed to parse. Whitespace expected at Line:1 Position: 19', I'm assuming the XML got garbled up somewhere in the process, but I can't figure our where I'm going wrong. Any ideas?

    Read the article

  • WpfToolkit DataGrid does not work in Windows Phone 7

    - by Igor Zevaka
    I am trying to use WpfToolkit DataGrid in Windows Phone 7 project (Silverligt 4) and it's not working. Here is the XAML: <UserControl x:Class="SilverlightControls.Grid" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:d="http://schemas.microsoft.com/expression/blend/2008" xmlns:mc="http://schemas.openxmlformats.org/markup-compatibility/2006" mc:Ignorable="d" xmlns:wtk="clr-namespace:Microsoft.Windows.Controls;assembly=WPFToolkit" d:DesignHeight="480" d:DesignWidth="480"> <Grid x:Name="LayoutRoot" Background="#FF1F1F1F" Width="960"> <Grid x:Name="TitleGrid"> <TextBlock Text="{Binding Title}" Style="{StaticResource PhoneTextPageTitle2Style}"/> </Grid> <wtk:DataGrid> </wtk:DataGrid> </Grid> </UserControl> The project compiles fine but crashes at runtime trying to load this control. The best clue I got so far is from Visual Studio Designer. Once I add wtk:DataGrid to the control the visual designer does not load and below is the exception it displays. Could it be that WpfToolkit relies on PresentationFramework.dll and it's not available in SL4? System.Reflection.Adds.UnresolvedAssemblyException Type universe cannot resolve assembly: PresentationFramework, Version=3.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35. at System.Reflection.Adds.AssemblyProxy.GetResolvedAssembly() at System.Reflection.Adds.AssemblyProxy.get_FullName() at Microsoft.Windows.Design.Metadata.ReflectionMetadataContext.PrepareAttributes(Reflectable`1 reflectableAssembly) at Microsoft.Windows.Design.Metadata.ReflectionMetadataContext.PrepareAttributes(Reflectable`1 reflectableType) at MS.Internal.Metadata.ClrType.GetAttributes[T](ReflectionMetadataContext context, IReflectable`1 member, ITypeMetadata attributeType, Boolean merge, AttributeMergeCache& cache) at MS.Internal.Metadata.ClrMember`1.GetLocalAttributes(ITypeMetadata attributeType) at MS.Internal.Design.Metadata.Xaml.XamlType.GetSpecialProperty(Int32 idx, PropertyIdentifier pid) at MS.Internal.Design.Metadata.Xaml.XamlType.get_ContentProperty() at Microsoft.Windows.Design.Metadata.Xaml.XamlExtensionImplementations.GetContentProperty(ITypeMetadata sourceType) at Microsoft.Windows.Design.Metadata.Xaml.XamlExtensions.GetContentProperty(ITypeMetadata source) at MS.Internal.Design.Metadata.ReflectionTypeNode.get_ContentProperty() at MS.Internal.Design.Markup.XmlElement.CalcChildWhitespaceImportant(XamlElement element) at MS.Internal.Design.Markup.XmlElement.ConvertChildrenToXaml(XamlElement result, PrefixScope scope, IParseContext context, IMarkupSourceProvider provider, Boolean childrenAsString) at MS.Internal.Design.Markup.XmlElement.ConvertToXaml(XamlElement parent, PrefixScope parentScope, IParseContext context, IMarkupSourceProvider provider) at MS.Internal.Design.Markup.XmlElement.ConvertChildrenToXaml(XamlElement result, PrefixScope scope, IParseContext context, IMarkupSourceProvider provider, Boolean childrenAsString) at MS.Internal.Design.Markup.XmlElement.ConvertToXaml(XamlElement parent, PrefixScope parentScope, IParseContext context, IMarkupSourceProvider provider) at MS.Internal.Design.DocumentModel.DocumentTrees.Markup.XamlSourceDocument.ParseElementFromSkeleton(XamlParseContext context, SkeletonNode node, XamlElement parent, Boolean fullElement) at MS.Internal.Design.DocumentModel.DocumentTrees.Markup.XamlSourceDocument.UpdateSkeleton(IDamageListener listener) at Microsoft.Windows.Design.DocumentModel.Trees.MarkupDocumentTreeManager.Update() at Microsoft.Windows.Design.DocumentModel.MarkupProducer.Update() at Microsoft.Windows.Design.DocumentModel.MarkupProducer.HandleMessage(DocumentTreeCoordinator sender, MessageKey key, MessageArguments args) at Microsoft.Windows.Design.DocumentModel.MarkupProducer.Microsoft.Windows.Design.DocumentModel.IDocumentTreeConsumer.HandleMessage(DocumentTreeCoordinator sender, MessageKey key, MessageArguments args) at Microsoft.Windows.Design.DocumentModel.DocumentTreeCoordinator.SendMessage[T](MessageKey`1 key, T args, Boolean isPrivateMessage) at Microsoft.Windows.Design.DocumentModel.DocumentTreeCoordinator.QueuedMessage`1.Microsoft.Windows.Design.DocumentModel.IQueuedMessage.Invoke() at Microsoft.Windows.Design.DocumentModel.DocumentTreeCoordinator.ProcessQueuedMessages(Object state) at System.Windows.Threading.ExceptionWrapper.InternalRealCall(Delegate callback, Object args, Int32 numArgs) at MS.Internal.Threading.ExceptionFilterHelper.TryCatchWhen(Object source, Delegate method, Object args, Int32 numArgs, Delegate catchHandler)

    Read the article

  • TFS and shared projects in multiple solutions

    - by David Stratton
    Our .NET team works on projects for our company that fall into distinct categories. Some are internal web apps, some are external (publicly facing) web apps, we also have internal Windows applications for our corporate office users, and Windows Forms apps for our retail locations (stores). Of course, because we hate code reuse, we have a ton of code that is shared among the different applications. Currently we're using SVN as our source control, and we've got our repository laid out like this: - = folder, | = Visual Studio Solution -SVN - Internet | Ourcompany.com | Oursecondcompany.com - Intranet | UniformOrdering website | MessageCenter website - Shared | ErrorLoggingModule | RegularExpressionGenerator | Anti-Xss | OrgChartModule etc... So.. The OurCompany.com solution in the Internet folder would have a website project, and it would also include the ErrorLoggingModule, RegularExpressionGenerator, and Anti-Xss projects from the shared directory. Similarly, our UniformOrdering website solution would have each of these projects included in the solution as well. We prefer to have a project reference to a .dll reference because, first of all, if we need to add or fix a function in the ErrorLoggingModule while working on the OurCompany.com website, it's right there. Also, this allows us to build each solution and see if changes to shared code break any other applications. This should work well on a build server as well if I'm correct. In SVN, there is no problem with this. SVN and Visual Studio aren't tied together in the way TFS's source control is. We never figured out how to work this type of structure in TFS when we were using it, because in TFS, the TFS project was always tied to a Visual Studio Solution. The Source Code repository was a child of the TFS Project, so if we wanted to do this, we had to duplicate the Shared code in each TFS project's source code repository. As my co-worker put it, this "breaks every known best practice about code reuse and simplicity". It was enough of a deal breaker for us that we switched to SVN. Now, however, we're faced with truly fixing our development processes, and the Application Lifecycle Management of TFS is pretty close to exactly what we want, and how we want to work. Our one sticking point is the shared code issue. We're evaluating other commercial and open source solutions, but since we're already paying for TFS with our MSDN Subscriptions, and TFS is pretty much exactly what we want, we'd REALLY like to find a way around this issue. Has anybody else faced this and come up with a solution? If you've seen an article or posting on this that you can share with me, that would help as well. As always, I'm open to answers like "You're looking at it all wrong, bonehead, HERE'S the way it SHOULD be done.

    Read the article

  • problem with NHibernate and iSeries DB2

    - by chrisjlong
    Ok So I have an AS400/iSeries running v5r4. I have an application that was using classic NHibernate to connect and do some basic crud. Now I have pulled that app (which sat for 2 years) off the shelf of TFS and onto a new PC and cannot seem to get it running. Here is my Hibernate Config: <hibernate-configuration xmlns="urn:nhibernate-configuration-2.2"> <session-factory> <property name="connection.provider"> NHibernate.Connection.DriverConnectionProvider </property> <property name="dialect"> NHibernate.Dialect.DB2400Dialect </property> <property name="proxyfactory.factory_class">NHibernate.ByteCode.LinFu.ProxyFactoryFactory, NHibernate.ByteCode.LinFu</property> <property name="connection.connection_string"> DataSource=207.206.106.19; Database=AS400; userID=XXXXXX; Password=XXXXXXX; LibraryList=FMSFILTST,BEFFILT,HRDBFT,HRCSTFT,J20##X2DEV,GLCUSTDEV,OSL@@F3DEV; Naming=System; Initial Catalog=*SYSBAS; </property> <property name="use_outer_join">true</property> <property name="query.substitutions"> true 1, false 0, yes 'Y', no 'N' </property> <property name="show_sql">false</property> <mapping assembly="BusinessLogic" /> </session-factory> </hibernate-configuration> I have all the proper DLL's included (NHibernate, castle, iesi, antlr3 , log4 etc). Also have this line in my web.config <runtime> <assemblyBinding> <qualifyAssembly partialName="IBM.Data.DB2.iSeries" fullName="IBM.Data.DB2.iSeries,Version=10.0.0.0,PublicKeyToken=9CDB2EBFB1F93A26,Culture=neutral"/> </assemblyBinding> </runtime> Yet I am still getting the following error as soon as I call NHibernate.Cfg.Configuration().Configure().BuildSessionFactory().OpenSession(); The error is as follows Unable to cast object of type 'IBM.Data.DB2.iSeries.iDB2Connection' to type 'System.Data.Common.DbCommand' I am dying to get some help with this. Any assistance is appreciated. Thanks!

    Read the article

  • Importing CSV filte to SQL server...

    - by sam
    HI guys, I am trying to import CSV file to SQL server database, no success, I am still newbie to sql server, thanks Operation stopped... Initializing Data Flow Task (Success) Initializing Connections (Success) Setting SQL Command (Success) Setting Source Connection (Success) Setting Destination Connection (Success) Validating (Success) Messages Warning 0x80049304: Data Flow Task 1: Warning: Could not open global shared memory to communicate with performance DLL; data flow performance counters are not available. To resolve, run this package as an administrator, or on the system's console. (SQL Server Import and Export Wizard) Prepare for Execute (Success) Pre-execute (Success) Messages Information 0x402090dc: Data Flow Task 1: The processing of file "D:\test.csv" has started. (SQL Server Import and Export Wizard) Executing (Error) Messages Error 0xc002f210: Drop table(s) SQL Task 1: Executing the query "drop table [dbo].[test] " failed with the following error: "Cannot drop the table 'dbo.test', because it does not exist or you do not have permission.". Possible failure reasons: Problems with the query, "ResultSet" property not set correctly, parameters not set correctly, or connection not established correctly. (SQL Server Import and Export Wizard) Error 0xc02020a1: Data Flow Task 1: Data conversion failed. The data conversion for column ""Code"" returned status value 4 and status text "Text was truncated or one or more characters had no match in the target code page.". (SQL Server Import and Export Wizard) Error 0xc020902a: Data Flow Task 1: The "output column ""Code"" (38)" failed because truncation occurred, and the truncation row disposition on "output column ""Code"" (38)" specifies failure on truncation. A truncation error occurred on the specified object of the specified component. (SQL Server Import and Export Wizard) Error 0xc0202092: Data Flow Task 1: An error occurred while processing file "D:\test.csv" on data row 21. (SQL Server Import and Export Wizard) Error 0xc0047038: Data Flow Task 1: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED. The PrimeOutput method on component "Source - test_csv" (1) returned error code 0xC0202092. The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing. There may be error messages posted before this with more information about the failure. (SQL Server Import and Export Wizard) Copying to [dbo].[test] (Stopped) Post-execute (Success) Messages Information 0x402090dd: Data Flow Task 1: The processing of file "D:\test.csv" has ended. (SQL Server Import and Export Wizard) Information 0x402090df: Data Flow Task 1: The final commit for the data insertion in "component "Destination - test" (70)" has started. (SQL Server Import and Export Wizard) Information 0x402090e0: Data Flow Task 1: The final commit for the data insertion in "component "Destination - test" (70)" has ended. (SQL Server Import and Export Wizard) Information 0x4004300b: Data Flow Task 1: "component "Destination - test" (70)" wrote 0 rows. (SQL Server Import and Export Wizard)

    Read the article

  • Why Moq is throwing "expected Invocation on the mock at least once". Where as it is being set once,e

    - by Mohit
    Following is the code. create a class lib add the ref to NUnit framework 2.5.3.9345 and Moq.dll 4.0.0.0 and paste the following code. Try running it on my machine it throws TestCase 'MoqTest.TryClassTest.IsMessageNotNull' failed: Moq.MockException : Expected invocation on the mock at least once, but was never performed: v = v.Model = It.Is(value(Moq.It+<c__DisplayClass21[MoqTest.GenInfo]).match) at Moq.Mock.ThrowVerifyException(IProxyCall expected, Expression expression, Times times, Int32 callCount) at Moq.Mock.VerifyCalls(Interceptor targetInterceptor, MethodCall expected, Expression expression, Times times) at Moq.Mock.VerifySet[T](Mock1 mock, Action1 setterExpression, Times times, String failMessage) at Moq.Mock1.VerifySet(Action`1 setterExpression) Class1.cs(22,0): at MoqTest.TryClassTest.IsMessageNotNull() using System; using System.Collections.Generic; using System.Linq; using System.Text; using Moq; using NUnit.Framework; namespace MoqTest { [TestFixture] public class TryClassTest { [Test] public void IsMessageNotNull() { var mockView = new Mock<IView<GenInfo>>(); mockView.Setup(v => v.ModuleId).Returns(""); TryPresenter tryPresenter = new TryPresenter(mockView.Object); tryPresenter.SetMessage(new object(), new EventArgs()); // mockView.VerifySet(v => v.Message, Times.AtLeastOnce()); mockView.VerifySet(v => v.Model = It.Is<GenInfo>(x => x != null)); } } public class TryPresenter { private IView<GenInfo> view; public TryPresenter(IView<GenInfo> view) { this.view = view; } public void SetMessage(object sender, EventArgs e) { this.view.Model = null; } } public class MyView : IView<GenInfo> { #region Implementation of IView<GenInfo> public string ModuleId { get; set; } public GenInfo Model { get; set; } #endregion } public interface IView<T> { string ModuleId { get; set; } T Model { get; set; } } public class GenInfo { public String Message { get; set; } } } And if you change one line mockView.VerifySet(v => v.Model = It.Is<GenInfo>(x => x != null)); to mockView.VerifySet(v => v.Model, Times.AtLeastOnce()); it works fine. I think Exception is incorrect.

    Read the article

  • What might cause this ExecutionEngineException?

    - by Qwertie
    I am trying to use Reflection.Emit to generate a wrapper class in a dynamic assembly. Automatic wrapper generation is part of a new open-source library I'm writing called "GoInterfaces". The wrapper class implements IEnumerable<string> and wraps List<string>. In C# terms, all it does is this: class List1_7931B0B4_79328AA0 : IEnumerable<string> { private readonly List<string> _obj; public List1_7931B0B4_79328AA0(List<string> obj) { this._obj = obj; } IEnumerator IEnumerable.GetEnumerator() { return this._obj.GetEnumerator(); } public sealed IEnumerator<string> GetEnumerator() { return this._obj.GetEnumerator(); } } However, when I try to call the GetEnumerator() method on my wrapper class, I get ExecutionEngineException. So I saved my dynamic assembly to a DLL and used ildasm on it. Is there anything wrong with the following code? .class public auto ansi sealed List`1_7931B0B4_79328AA0 extends [mscorlib]System.Object implements [mscorlib]System.Collections.Generic.IEnumerable`1<string>, [Loyc.Runtime]Loyc.Runtime.IGoInterfaceWrapper { .field private initonly class [mscorlib]System.Collections.Generic.List`1<string> _obj .method public hidebysig virtual final instance class [mscorlib]System.Collections.Generic.IEnumerator`1<string> GetEnumerator() cil managed { // Code size 12 (0xc) .maxstack 1 IL_0000: ldarg.0 IL_0001: ldfld class [mscorlib]System.Collections.Generic.List`1<string> List`1_7931B0B4_79328AA0::_obj IL_0006: call instance valuetype [mscorlib]System.Collections.Generic.List`1/Enumerator<!0> class [mscorlib]System.Collections.Generic.List`1<string>::GetEnumerator() IL_000b: ret } // end of method List`1_7931B0B4_79328AA0::GetEnumerator .method public hidebysig virtual final instance class [mscorlib]System.Collections.IEnumerator System.Collections.IEnumerable.GetEnumerator() cil managed { .override [mscorlib]System.Collections.IEnumerable::GetEnumerator // Code size 12 (0xc) .maxstack 1 IL_0000: ldarg.0 IL_0001: ldfld class [mscorlib]System.Collections.Generic.List`1<string> List`1_7931B0B4_79328AA0::_obj IL_0006: call instance valuetype [mscorlib]System.Collections.Generic.List`1/Enumerator<!0> class [mscorlib]System.Collections.Generic.List`1<string>::GetEnumerator() IL_000b: ret } // end of method List`1_7931B0B4_79328AA0::System.Collections.IEnumerable.GetEnumerator ... I have a test suite that wraps all sorts of different things, including interfaces derived from other interfaces, and multiple interface methods with identical signatures. It's only when I try to wrap IEnumerable<T> that this problem occurs. I'd be happy to send the source code (2 *.cs files, no dependencies) if anyone would like.

    Read the article

  • How can I load style resources from a dynamically loaded Silverlight application (XAP)?

    - by Tom
    I've followed Tim Heuer's video for dynamically loading other XAP's (into a 'master' Silverlight application), as well as some other links to tweak the loading of resources and am stuck on the particular issue of loading style resources from within the dynamically loaded XAP (i.e. the contents of Assets\Styles.xaml). When I run the master/hosting applcation, it successfully streams the dynamic XAP and I can read the deployment info etc. and load the assembly parts. However, when I actuall try to create an instance of a form from the Dynamic XAP, it fails with Cannot find a Resource with the Name/Key LayoutRootGridStyle which is in it's Assets\Styles.xaml file (it works if I run it directly so I know it's OK). For some reason these don't show up as application resources - not sure if I've totally got the wrong end of the stick, or am just missing something? Code snippet below (apologies it's a bit messy - just trying to get it working first) ... '' # Here's the code that reads the dynamic XAP from the web server ... '' #... wCli = New WebClient AddHandler wCli.OpenReadCompleted, AddressOf OpenXAPCompleted wCli.OpenReadAsync(New Uri("MyTest.xap", UriKind.Relative)) '' #... '' #Here's the sub that's called when openread is completed '' #... Private Sub OpenXAPCompleted(ByVal sender As Object, ByVal e As System.Net.OpenReadCompletedEventArgs) Dim sManifest As String = New StreamReader(Application.GetResourceStream(New StreamResourceInfo(e.Result, Nothing), New Uri("AppManifest.xaml", UriKind.Relative)).Stream).ReadToEnd Dim deploymentRoot As XElement = XDocument.Parse(sManifest).Root Dim deploymentParts As List(Of XElement) = _ (From assemblyParts In deploymentRoot.Elements().Elements() Select assemblyParts).ToList() Dim oAssembly As Assembly = Nothing For Each xElement As XElement In deploymentParts Dim asmPart As AssemblyPart = New AssemblyPart() Dim source As String = xElement.Attribute("Source").Value Dim sInfo As StreamResourceInfo = Application.GetResourceStream(New StreamResourceInfo(e.Result, "application/binary"), New Uri(source, UriKind.Relative)) If source = "MyTest.dll" Then oAssembly = asmPart.Load(sInfo.Stream) Else asmPart.Load(sInfo.Stream) End If Next Dim t As Type() = oAssembly.GetTypes() Dim AppClass = (From parts In t Where parts.FullName.EndsWith(".App") Select parts).SingleOrDefault() Dim mykeys As Array If Not AppClass Is Nothing Then Dim a As Application = DirectCast(oAssembly.CreateInstance(AppClass.FullName), Application) For Each strKey As String In a.Resources.Keys If Not Application.Current.Resources.Contains(strKey) Then Application.Current.Resources.Add(strKey, a.Resources(strKey)) End If Next End If Dim objectType As Type = oAssembly.GetType("MyTest.MainPage") Dim ouiel = Activator.CreateInstance(objectType) Dim myData As UIElement = DirectCast(ouiel, UIElement) Me.splMain.Children.Add(myData) Me.splMain.UpdateLayout() End Sub '' #... '' # And here's the line that fails with "Cannot find a Resource with the Name/Key LayoutRootGridStyle" '' # ... System.Windows.Application.LoadComponent(Me, New System.Uri("/MyTest;component/MainPage.xaml", System.UriKind.Relative)) '' #... any thoughts?

    Read the article

  • "Bad binary signature" in ASP.NET MVC application

    - by David M
    We are getting the error above on some pages of an ASP.NET MVC application when it is deployed to a 64 bit Windows 2008 server box. It works fine on our development machines, though these are 32 bit XP. Just wondered if anyone had encountered this before, and has any suggestions? Details as follows: Bad binary signature. (Exception from HRESULT: 0x80131192) Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Runtime.InteropServices.COMException: Bad binary signature. (Exception from HRESULT: 0x80131192) All projects are set to compile for Any CPU, and are compiled in Release mode. The ASP.NET site is precompiled, and the precompiled build is on a 64 bit Windows 2008 TeamCity build agent. Thanks in advance. EDIT We're still plagued by this. I have looked at all the binaries in the website's bin directory using corflags.exe. None has the 32BIT flag set, and all have a CorFlags value of 9 except for Antlr3.Runtime.dll which has a value of 1. The problem only affects certain pages, and it seems to be those which use FluentValidation (including FluentValidation.Mvc and FluentValidation.xValIntegration assemblies). None of these shows anything out of the ordinary when inspected with corflags.exe, and there are no odd looking dependencies revealed by ildasm. When built locally (32 bit Windows XP) the site deploys and runs fine. When built on the build agents (64 bit Windows 2008 Server) the site displays these errors. The site runs in Integrated Pipeline mode, and is not set to 32 bit. The stack trace is: [COMException (0x80131192): Bad binary signature. (Exception from HRESULT: 0x80131192)] ASP.views_user_newinternal_aspx.__RenderContent2(HtmlTextWriter __w, Control parameterContainer) in e:\TeamCity\buildAgent\work\605ee6b4a5d1dd36\...Admin.Mvc\Views\User\NewInternal.aspx:53 System.Web.UI.Control.RenderChildrenInternal(HtmlTextWriter writer, ICollection children) +115 ASP.views_shared_site_master.__Render__control1(HtmlTextWriter __w, Control parameterContainer) in e:\TeamCity\buildAgent\work\605ee6b4a5d1dd36\...Admin.Mvc\Views\Shared\Site.Master:26 System.Web.UI.Control.RenderChildrenInternal(HtmlTextWriter writer, ICollection children) +115 System.Web.UI.Control.RenderChildrenInternal(HtmlTextWriter writer, ICollection children) +240 System.Web.UI.Page.Render(HtmlTextWriter writer) +38 System.Web.Mvc.ViewPage.Render(HtmlTextWriter writer) +94 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +4240

    Read the article

  • Add Silverlight Bing Maps Control to Windows Mobile 7 application

    - by Jacob
    I know the bits just came out today, but one of the first things I want to do with the newly released Windows Mobile 7 SDK is put a map up on the screen and mess around. I've downloaded the latest version of the Silverlight Maps Control and added the references to my application. As a matter of fact, the VS 2010 design view of the MainPage.xaml shows the map control after adding the namespace and placing the control. I'm using the provided VS 2010 Express version that comes with the Win Mobile 7 SDK and have just used the New Project - Windows Phone Application template. When I try to build I get two warnings related to the Microsoft.Maps.MapControl dll's. Warning 1 The primary reference "Microsoft.Maps.MapControl, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" could not be resolved because it has an indirect dependency on the framework assembly "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e" which could not be resolved in the currently targeted framework. "Silverlight,Version=v4.0,Profile=WindowsPhone". To resolve this problem, either remove the reference "Microsoft.Maps.MapControl, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" or retarget your application to a framework version which contains "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e". Warning 2 The primary reference "Microsoft.Maps.MapControl.Common, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" could not be resolved because it has an indirect dependency on the framework assembly "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e" which could not be resolved in the currently targeted framework. "Silverlight,Version=v4.0,Profile=WindowsPhone". To resolve this problem, either remove the reference "Microsoft.Maps.MapControl.Common, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" or retarget your application to a framework version which contains "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e". I'm leaning towards some way of adding the System.Windows.Browser to the targeted framework version. But I'm not even sure if that is possible. To be more specific; I'm looking for a way to get the Silverlight Maps Control up on a Windows Phone 7 series application. If possible. Thanks.

    Read the article

  • Installing Monodevelop from the SVN on Ubuntu 10.04

    - by celil
    I wrote the following script to install the svn version of MonoDevelop #!/usr/bin/env bash PREFIX=/opt/local check_errs() { if [[ $? -ne 0 ]]; then echo "${1}" exit 1 fi } download() { if [ ! -d ${1} ] then svn co http://anonsvn.mono-project.com/source/trunk/${1} else (cd ${1}; svn update) fi } download mono download mcs download libgdiplus ( cd mono ./autogen.sh --prefix=$PREFIX make make install check_errs ) ( cd libgdiplus ./autogen.sh --prefix=$PREFIX make make install check_errs ) download monodevelop export PKG_CONFIG_PATH=${PREFIX}/lib/pkgconfig ( cd monodevelop ./configure --prefix=$PREFIX --select check_errs make check_errs ) Everything works fine until the last make step for the monodevelop pacakge, where the script exits with the error: ./MonoDevelop.WebReferences/MoonlightChannelBaseExtension.cs(320,82): error CS1061: Type `System.ServiceModel.Description.OperationContractGenerationContext' does not contain a definition for `SyncMethod' and no extension method `SyncMethod' of type `System.ServiceModel.Description.OperationContractGenerationContext' could be found (are you missing a using directive or an assembly reference?) ./MonoDevelop.WebReferences/MoonlightChannelBaseExtension.cs(325,49): error CS1061: Type `System.ServiceModel.Description.OperationContractGenerationContext' does not contain a definition for `SyncMethod' and no extension method `SyncMethod' of type `System.ServiceModel.Description.OperationContractGenerationContext' could be found (are you missing a using directive or an assembly reference?) ./MonoDevelop.WebReferences/MoonlightChannelBaseExtension.cs(345,115): error CS1061: Type `System.ServiceModel.Description.OperationContractGenerationContext' does not contain a definition for `SyncMethod' and no extension method `SyncMethod' of type `System.ServiceModel.Description.OperationContractGenerationContext' could be found (are you missing a using directive or an assembly reference?) ./MonoDevelop.WebReferences/MoonlightChannelBaseExtension.cs(365,82): error CS1061: Type `System.ServiceModel.Description.OperationContractGenerationContext' does not contain a definition for `BeginMethod' and no extension method `BeginMethod' of type `System.ServiceModel.Description.OperationContractGenerationContext' could be found (are you missing a using directive or an assembly reference?) Compilation failed: 4 error(s), 1 warnings make[4]: *** [../../../build/AddIns/MonoDevelop.WebReferences/MonoDevelop.WebReferences.dll] Error 1 make[4]: Leaving directory `/home/drufat/Desktop/Checkout/mono/monodevelop/main/src/addins/MonoDevelop.WebReferences' make[3]: *** [all-recursive] Error 1 make[3]: Leaving directory `/home/drufat/Desktop/Checkout/mono/monodevelop/main/src/addins' make[2]: *** [all-recursive] Error 1 make[2]: Leaving directory `/home/drufat/Desktop/Checkout/mono/monodevelop/main/src' make[1]: *** [all-recursive] Error 1 make[1]: Leaving directory `/home/drufat/Desktop/Checkout/mono/monodevelop/main' make: *** [all-recursive] Error 1 Any ideas on how to fix this? I suppose the build gets mixed up with the default installation of mono in Ubuntu, and is looking for a symbol that is not present there. My build configuration looks as follows: 1. [X] main 2. [ ] extras/JavaBinding 3. [ ] extras/BooBinding 4. [X] extras/ValaBinding 5. [ ] extras/AspNetEdit 6. [ ] extras/GeckoWebBrowser 7. [ ] extras/WebKitWebBrowser 8. [ ] extras/MonoDevelop.Database 9. [ ] extras/MonoDevelop.Profiling 10. [ ] extras/MonoDevelop.AddinAuthoring 11. [ ] extras/MonoDevelop.CodeAnalysis 12. [ ] extras/MonoDevelop.Debugger.Mdb 13. [ ] extras/MonoDevelop.Debugger.Gdb 14. [ ] extras/PyBinding 15. [ ] extras/MonoDevelop.IPhone 16. [ ] extras/MonoDevelop.MeeGo

    Read the article

  • Problem with waveOutWrite and waveOutGetPosition deadlock

    - by MusiGenesis
    I'm working on an app that plays audio continuously using the waveOut... API from winmm.dll. The app uses "leapfrog" buffers, which are basically a bunch of arrays of samples that you dump into the audio queue. Windows plays them seamlessly in sequence, and as each buffer completes Windows calls a callback function. Inside this function, I load the next set of samples into the buffer, process them however, and then dump the buffer back into the audio queue. In this way, the audio plays indefinitely. For animation purposes, I'm trying to incorporate waveOutGetPosition into the application (since the "buffer done" callbacks are irregular enough to cause jerky animation). waveOutGetPosition returns the current position of playback, so it's hyper-precise. The problem is that in my application, making calls to waveOutGetPosition eventually causes the application to lock up - the sound stops and the call never returns. I've boiled things down to a simple app that demonstrates the problem. You can run the app here: http://www.musigenesis.com/SO/waveOut%20demo.exe If you just hear a tiny bit of piano over and over, it's working. It's just meant to demonstrate the problem. The source code for this project is here: http://www.musigenesis.com/SO/WaveOutDemo.zip The first button runs the app in leapfrog mode without making the calls to waveOutGetPosition. If you click this, the app will play forever without breaking (the X button will close it and shut it off). The second button starts the leapfrogger and also starts a forms timer that calls the waveOutGetPosition and displays the current position. Click this and the app will run for a short while and then lock up. On my laptop, it usually locks up in 15-30 seconds; at most it's taken a minute. I have no idea how to fix this, so any help or suggestions would be most welcome. I've found very few posts on this issue, but it seems that there is a potential deadlock, either from multiple calls to waveOutGetPosition or from calls to that and waveOutWrite that occur at the same time. It's possible that I'm calling this too frequently for the system to handle.

    Read the article

  • PHP5.3 is not working with MySQL5.1 IIS7 Times out

    - by Thorn007
    I have set up PHP5.3, MySQL5.1, and IIS7 on Window 7 but php doesn't want to work with MySQL. I'm assuming it is a configuration error or an incomplete install on my part. MySQL5.1 is working PHP5.3 is working, phpinfo() shows info and that i have enabled MySQL IIS is setup and using fastCgiModule to run PHP IIS registers php.ini updates port 3306 is firewall free and open to the world php.ini is configured correctly I have added c:\php to the Windows systems PATH In the past I remember moving a file, libmysql.dll, to System32 but I doesn't look like that come with php5.3.1, as the driver comes built in now http://us3.php.net/manual/en/mysqlnd.install.php. (This has been giving me so much trouble I have been documenting my findings on my blog as http://inteldesigner.com/2010/code/having-problems-getting-php5-3-to-work-with-mysql5-1 ) NEED: I need to install PHP manually, don't want to use the quick installer or an older version I need to get PHP5.3 to work with MySQL5.1 so i can install Wordpress2.9 and Drupal7a Any links or suggestion would be great, I have already done everything on the iis web site, nothing is working. I'm guessing they have not updated for new software. BUGS/SOLUTION: The solution is here: http://bugs.php.net/bug.php?id=50172 thanks go to don.raman on the iis.net forums http://forums.iis.net/p/1164911/1933894.aspx SYMPTOMS: The php function mysql_connect() in conjunction with php5.3 locks up sever and returns error 500. (IPv6 is the problem see above link) TEST CODE: <?php $con = mysql_connect("localhost","root","***"); if (!$con) { die('Could not connect: ' . mysql_error()); } // some code mysql_close($con); ?> ERRORS: From Browser: HTTP Error 500.0 - Internal Server Error C:\php\php-cgi.exe - The FastCGI process exceeded configured activity timeout When i run php -f c:\public_html\index.php from the command line i got: PHP Warning: mysql_connect(): [2002] A connection attempt failed because the co nnected party did not (trying to connect via tcp://localhost:3306) in C:\public _html\index.php on line 10 Warning: mysql_connect(): [2002] A connection attempt failed because the connect ed party did not (trying to connect via tcp://localhost:3306) in C:\public_html \index.php on line 10 PHP Warning: mysql_connect(): A connection attempt failed because the connected party did not properly respond after a period of time, or established connectio n failed because connected host has failed to respond. in C:\public_html\index.php on line 10 Warning: mysql_connect(): A connection attempt failed because the connected part y did not properly respond after a period of time, or established connection fai led because connected host has failed to respond. in C:\public_html\index.php on line 10 Could not connect: A connection attempt failed because the connected party did n ot properly respond after a period of time, or established connection failed bec ause connected host has failed to respond. C:\Users\Kevin>

    Read the article

  • WinForms Menu Toolstrip Get Status

    - by Yeti
    So I have a project where there is some automatic initialization going on through some classes that are created automatically as global variables (yeah they are static instances). At a point inside this (it has no relation with the C# GUI for the user, so it isn't derived from any C# class) I need to see if a flag is set or not. I use toolstrip menu with checked and unchecked status in order to set or unset the flag. The problem is that I have difficulties to see if the flag is checked or not from this static class. My class is inside a different project/namespace and a DLL is created what later is linked to the GUI of the application. The GUI depends from this Manager class so making the Manager class to depend from the GUI is not an option. Nevertheless, I should be able to see its state knowing its name or through some other means. I have tried the following: if(Application.OpenForms[1].Owner.Controls["useLocalImageForInitToolStripMenuItem"].Enabled) { }; Now the problem is that on the upper code snippet I get a nasty error. So how do I do this? The toolstrip menu: The error: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ***** Exception Text ******* System.ArgumentOutOfRangeException: Index was out of range. Must be non-negative and less than the size of the collection. Parameter name: index at System.Collections.ArrayList.get_Item(Int32 index) at System.Windows.Forms.FormCollection.get_Item(Int32 index) at Manager.MyMainManager.MyMainManager.RealTimeInit() in C:\Dropbox\My Dropbox\Public\Program Code\RoboCup\Manager\MyMainManager\MyMainManager.cs:line 494 at mainApp.MainForm.ButtonInitClick(Object sender, EventArgs e) in C:\Dropbox\My Dropbox\Public\Program Code\RoboCup\mainApp\MainForm.cs:line 389 at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

    Read the article

  • OpenCV 2.4.2 on Matlab 2012b (Windows 7)

    - by Maik Xhani
    Hello i am trying to use OpenCV 2.4.2 in Matlab 2012b. I have tried those actions: downloaded OpenCV 2.4.2 used CMake on opencv folder using Visual Studio 10 and Visual Studio 10 Win64 compiler built Debug and Release version with Visual Studio first without any other option and then with D_SCL_SECURE=1 specified for every project changed Matlab's mexopts.bat and adding new lines refering to library and include (see bottom for mexopts.bat content) with Visual Studio 10 compiler tried to compile a simple file with a OpenCV library inclusion and all goes well. try to compile something that actually uses OpenCV commands and get errors. I used openmexopencv library and when tried to compile something i get this error cv.make mex -largeArrayDims -D_SECURE_SCL=1 -Iinclude -I"C:\OpenCV\build\include" -L"C:\OpenCV\build\x64\vc10\lib" -lopencv_calib3d242 -lopencv_contrib242 -lopencv_core242 -lopencv_features2d242 -lopencv_flann242 -lopencv_gpu242 -lopencv_haartraining_engine -lopencv_highgui242 -lopencv_imgproc242 -lopencv_legacy242 -lopencv_ml242 -lopencv_nonfree242 -lopencv_objdetect242 -lopencv_photo242 -lopencv_stitching242 -lopencv_ts242 -lopencv_video242 -lopencv_videostab242 src+cv\CamShift.cpp lib\MxArray.obj -output +cv\CamShift CamShift.cpp C:\Program Files\MATLAB\R2012b\extern\include\tmwtypes.h(821) : warning C4091: 'typedef ': ignorato a sinistra di 'wchar_t' quando non si dichiara alcuna variabile c:\program files\matlab\r2012b\extern\include\matrix.h(319) : error C4430: identificatore di tipo mancante, verr… utilizzato int. Nota: default-int non Š pi— supportato in C++ the content of my mexopts.bat is @echo off rem MSVC100OPTS.BAT rem rem Compile and link options used for building MEX-files rem using the Microsoft Visual C++ compiler version 10.0 rem rem $Revision: 1.1.6.4.2.1 $ $Date: 2012/07/12 13:53:59 $ rem Copyright 2007-2009 The MathWorks, Inc. rem rem StorageVersion: 1.0 rem C++keyFileName: MSVC100OPTS.BAT rem C++keyName: Microsoft Visual C++ 2010 rem C++keyManufacturer: Microsoft rem C++keyVersion: 10.0 rem C++keyLanguage: C++ rem C++keyLinkerName: Microsoft Visual C++ 2010 rem C++keyLinkerVersion: 10.0 rem rem ******************************************************************** rem General parameters rem ******************************************************************** set MATLAB=%MATLAB% set VSINSTALLDIR=c:\Program Files (x86)\Microsoft Visual Studio 10.0 set VCINSTALLDIR=%VSINSTALLDIR%\VC set OPENCVDIR=C:\OpenCV rem In this case, LINKERDIR is being used to specify the location of the SDK set LINKERDIR=c:\Program Files (x86)\Microsoft SDKs\Windows\v7.0A\ set PATH=%VCINSTALLDIR%\bin\amd64;%VCINSTALLDIR%\bin;%VCINSTALLDIR%\VCPackages;%VSINSTALLDIR%\Common7\IDE;%VSINSTALLDIR%\Common7\Tools;%LINKERDIR%\bin\x64;%LINKERDIR%\bin;%MATLAB_BIN%;%PATH% set INCLUDE=%OPENCVDIR%\build\include;%VCINSTALLDIR%\INCLUDE;%VCINSTALLDIR%\ATLMFC\INCLUDE;%LINKERDIR%\include;%INCLUDE% set LIB=%OPENCVDIR%\build\x64\vc10\lib;%VCINSTALLDIR%\LIB\amd64;%VCINSTALLDIR%\ATLMFC\LIB\amd64;%LINKERDIR%\lib\x64;%MATLAB%\extern\lib\win64;%LIB% set MW_TARGET_ARCH=win64 rem ******************************************************************** rem Compiler parameters rem ******************************************************************** set COMPILER=cl set COMPFLAGS=/c /GR /W3 /EHs /D_CRT_SECURE_NO_DEPRECATE /D_SCL_SECURE_NO_DEPRECATE /D_SECURE_SCL=0 /DMATLAB_MEX_FILE /nologo /MD set OPTIMFLAGS=/O2 /Oy- /DNDEBUG set DEBUGFLAGS=/Z7 set NAME_OBJECT=/Fo rem ******************************************************************** rem Linker parameters rem ******************************************************************** set LIBLOC=%MATLAB%\extern\lib\win64\microsoft set LINKER=link set LINKFLAGS=/dll /export:%ENTRYPOINT% /LIBPATH:"%LIBLOC%" libmx.lib libmex.lib libmat.lib /MACHINE:X64 kernel32.lib user32.lib gdi32.lib winspool.lib comdlg32.lib advapi32.lib shell32.lib ole32.lib oleaut32.lib uuid.lib odbc32.lib odbccp32.lib opencv_calib3d242.lib opencv_contrib242.lib opencv_core242.lib opencv_features2d242.lib opencv_flann242.lib opencv_gpu242.lib opencv_haartraining_engine.lib opencv_imgproc242.lib opencv_highgui242.lib opencv_legacy242.lib opencv_ml242.lib opencv_nonfree242.lib opencv_objdetect242.lib opencv_photo242.lib opencv_stitching242.lib opencv_ts242.lib opencv_video242.lib opencv_videostab242.lib /nologo /manifest /incremental:NO /implib:"%LIB_NAME%.x" /MAP:"%OUTDIR%%MEX_NAME%%MEX_EXT%.map" set LINKOPTIMFLAGS= set LINKDEBUGFLAGS=/debug /PDB:"%OUTDIR%%MEX_NAME%%MEX_EXT%.pdb" set LINK_FILE= set LINK_LIB= set NAME_OUTPUT=/out:"%OUTDIR%%MEX_NAME%%MEX_EXT%" set RSP_FILE_INDICATOR=@ rem ******************************************************************** rem Resource compiler parameters rem ******************************************************************** set RC_COMPILER=rc /fo "%OUTDIR%mexversion.res" set RC_LINKER= set POSTLINK_CMDS=del "%LIB_NAME%.x" "%LIB_NAME%.exp" set POSTLINK_CMDS1=mt -outputresource:"%OUTDIR%%MEX_NAME%%MEX_EXT%;2" -manifest "%OUTDIR%%MEX_NAME%%MEX_EXT%.manifest" set POSTLINK_CMDS2=del "%OUTDIR%%MEX_NAME%%MEX_EXT%.manifest" set POSTLINK_CMDS3=del "%OUTDIR%%MEX_NAME%%MEX_EXT%.map"

    Read the article

  • Still getting duplicate token error after calling DuplicateTokenEx for impersonated token

    - by atconway
    I'm trying to return a Sytem.IntPtr from a service call so that the client can use impersonation to call some code. My imersonation code works properly if not passing the token back from a WCF service. I'm not sure why this is not working. I get the following error: "Invalid token for impersonation - it cannot be duplicated." Here is my code that does work except when I try to pass the token back from a service to a WinForm C# client to then impersonate. [DllImport("advapi32.dll", EntryPoint = "DuplicateTokenEx")] public extern static bool DuplicateTokenEx(IntPtr ExistingTokenHandle, uint dwDesiredAccess, ref SECURITY_ATTRIBUTES lpThreadAttributes, int TokenType, int ImpersonationLevel, ref IntPtr DuplicateTokenHandle); private IntPtr tokenHandle = new IntPtr(0); private IntPtr dupeTokenHandle = new IntPtr(0); [StructLayout(LayoutKind.Sequential)] public struct SECURITY_ATTRIBUTES { public int Length; public IntPtr lpSecurityDescriptor; public bool bInheritHandle; } public enum SecurityImpersonationLevel { SecurityAnonymous = 0, SecurityIdentification = 1, SecurityImpersonation = 2, SecurityDelegation = 3 } public enum TokenType { TokenPrimary = 1, TokenImpersonation = 2 } private const int MAXIMUM_ALLOWED = 0x2000000; [PermissionSetAttribute(SecurityAction.Demand, Name = "FullTrust")] public System.IntPtr GetWindowsUserToken(string UserName, string Password, string DomainName) { IntPtr tokenHandle = new IntPtr(0); IntPtr dupTokenHandle = new IntPtr(0); const int LOGON32_PROVIDER_DEFAULT = 0; //This parameter causes LogonUser to create a primary token. const int LOGON32_LOGON_INTERACTIVE = 2; //Initialize the token handle tokenHandle = IntPtr.Zero; //Call LogonUser to obtain a handle to an access token for credentials supplied. bool returnValue = LogonUser(UserName, DomainName, Password, LOGON32_LOGON_INTERACTIVE, LOGON32_PROVIDER_DEFAULT, ref tokenHandle); //Make sure a token was returned; if no populate the ResultCode and throw an exception: int ResultCode = 0; if (false == returnValue) { ResultCode = Marshal.GetLastWin32Error(); throw new System.ComponentModel.Win32Exception(ResultCode, "API call to LogonUser failed with error code : " + ResultCode); } SECURITY_ATTRIBUTES sa = new SECURITY_ATTRIBUTES(); sa.bInheritHandle = true; sa.Length = Marshal.SizeOf(sa); sa.lpSecurityDescriptor = (IntPtr)0; bool dupReturnValue = DuplicateTokenEx(tokenHandle, MAXIMUM_ALLOWED, ref sa, (int)SecurityImpersonationLevel.SecurityDelegation, (int)TokenType.TokenImpersonation, ref dupTokenHandle); int ResultCodeDup = 0; if (false == dupReturnValue) { ResultCodeDup = Marshal.GetLastWin32Error(); throw new System.ComponentModel.Win32Exception(ResultCode, "API call to DuplicateToken failed with error code : " + ResultCode); } //Return the user token return dupTokenHandle; } Any idea if I'm not using the call to DuplicateTokenEx correctly? According to the MSDN documentation I read here I should be able to create a token valid for delegation and use across the context on remote systems. When 'SecurityDelegation' is used, the server process can impersonate the client's security context on remote systems. Thanks!

    Read the article

  • decrypt an encrypted value ?

    - by jim
    I have an old Paradox database (I can convert it to Access 2007) which contains more then 200,000 records. This database has two columns: the first one is named "Word" and the second one is named "Mean". It is a dictionary database and my client wants to convert this old database to ASP.NET and SQL. However, we don't know what key or method is used to encrypt or encode the "Mean" column which is in the Unicode format. The software itself has been written in Delphi 7 and we don't have the source code. My client only knows the credentials for logging in to database. The problem is decoding the Mean column. What I do have is the compiled windows application and the Paradox database. This software can decode the "Mean" column for each "Word" so the method and/or key is in its own compiled code(.exe) or one of the files in its directory. For example, we know that in the following row the "Zymurgy" exactly means "???? ??? ????? ?? ???? ????, ????? ?????" since the application translates it like that. Here is what the record looks like when I open the database in Access: Word Mean Zymurgy 5OBnGguKPdDAd7L2lnvd9Lnf1mdd2zDBQRxngsCuirK5h91sVmy0kpRcue/+ql9ORmP99Mn/QZ4= Therefore we're trying to discover how the value in the Mean column is converted to "???? ??? ????? ?? ???? ????, ????? ?????". I think the "Mean" column value in above row is encoded in Base64 string format, but decoding the Base64 string does not yet result in the expected text. The extensions for files in the win app directory are dll, CCC, DAT, exe (other than the main app file), SYS, FAM, MB, PX, TV, VAL. Any kind of help is appreciated. Additional information: guys! the creators are not that stupid to save the values only in encoded form. they're definitely encrypted them. so i guess we have to look for the key.

    Read the article

  • CCNet web dashboard not showing anything when MSBuild fails

    - by cfdev9
    I have a simple project in ccnet using svn & msbuild only. There is a 30 second trigger for svn and the msbuild file compiles a web application then copies it to a numbered build folder. When an error occurs in the msbuild task I get a failed build. When I view a failed build in the web dashboard I can see the 'Modifications since last build' section in the dashboard, but nothing else. I have to click on the build log and read through all of the xml in the error log to see what the error was. Why won't the dashboard show the errors from the build log? I haven't changed anything in the dashboard.config since installing ccnet. Dashboard Version : 1.5.7256.1 <project name="SimpleWebapp1"> <artifactDirectory>C:\Program Files\CruiseControl.NET\server\SimpleWebapp1\Artifacts\</artifactDirectory> <triggers> <intervalTrigger name="continuous" seconds="30" buildCondition="IfModificationExists" initialSeconds="5" /> </triggers> <sourcecontrol type="svn"> <executable>C:\Program Files\CollabNet\Subversion Client\svn.exe</executable> <trunkUrl>https://server:8443/svn/SimpleWebapp1/trunk</trunkUrl> <workingDirectory>D:\CCNetSandbox\SimpleWebapp1</workingDirectory> <username>username</username> <password>password</password> </sourcecontrol> <tasks> <msbuild> <executable> C:\WINDOWS\Microsoft.NET\Framework\v3.5\MSBuild.exe </executable> <workingDirectory> D:\CCNetSandbox\SimpleWebapp1 </workingDirectory> <projectFile>SimpleWebapp1.build</projectFile> <buildArgs>/p:Configuration=Debug /p:Platform="Any CPU"</buildArgs> <targets>CompileLatest</targets> <timeout>900</timeout> <logger>ThoughtWorks.CruiseControl.MsBuild.XMLLogger, C:\Program Files\CruiseControl.NET\server\ThoughtWorks.CruiseControl.MsBuild.dll</logger> </msbuild> </tasks> <publishers> <xmllogger /> <buildpublisher> <publishDir>C:\Program Files\CruiseControl.NET\server\SimpleWebapp1\Artifacts\</publishDir> <useLabelSubDirectory>true</useLabelSubDirectory> </buildpublisher> </publishers> </project>

    Read the article

  • Svcutil generating bad config with multiple endpoints

    - by vfilby
    I have a WCF service that has exposed a soap and an xml endpoint. When I use svcutil to generate the proxy code on the client side the generated configuration contains two endpoints which causes the client to fail. If I edit the web.config file and remove the second endpoint (with the custom binding) all works as expected. Is there a way I can get svcutil to generate a config that just works so that I don't need to hand edit the file everytime? Client-side error: An endpoint configuration section for contract 'MyNamespace.ITestService' could not be loaded because more than one endpoint configuration for that contract was found. Please indicate the preferred endpoint configuration section by name. Svcutil command: svcutil http://api.local/Test.svc /reference:bin\MyNamespace.Interface.dll /config:web.config /mergeConfig /out:"Service References\TestService.cs" /n:*,MyNamespace Generated client config: <system.serviceModel> <bindings> <basicHttpBinding> <binding name="BasicHttpBinding_ITestService" closeTimeout="00:01:00" openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:01:00" allowCookies="false" bypassProxyOnLocal="false" hostNameComparisonMode="StrongWildcard" maxBufferSize="65536" maxBufferPoolSize="524288" maxReceivedMessageSize="65536" messageEncoding="Text" textEncoding="utf-8" transferMode="Buffered" useDefaultWebProxy="true"> <readerQuotas maxDepth="32" maxStringContentLength="8192" maxArrayLength="16384" maxBytesPerRead="4096" maxNameTableCharCount="16384" /> <security mode="None"> <transport clientCredentialType="None" proxyCredentialType="None" realm="" /> <message clientCredentialType="UserName" algorithmSuite="Default" /> </security> </binding> </basicHttpBinding> <customBinding> <binding name="CustomBinding_ITestService"> <textMessageEncoding maxReadPoolSize="64" maxWritePoolSize="16" messageVersion="Soap12" writeEncoding="utf-8"> <readerQuotas maxDepth="32" maxStringContentLength="8192" maxArrayLength="16384" maxBytesPerRead="4096" maxNameTableCharCount="16384" /> </textMessageEncoding> </binding> </customBinding> </bindings> <client> <endpoint address="http://api2.local/Test.svc/soap" binding="basicHttpBinding" bindingConfiguration="BasicHttpBinding_ITestService" contract="MyNamespace.ITestService" name="BasicHttpBinding_ITestService" /> <endpoint binding="customBinding" bindingConfiguration="CustomBinding_ITestService" contract="MyNamespace.ITestService" name="CustomBinding_ITestService" /> </client> </system.serviceModel>

    Read the article

  • Cannot add Silverlight Maps Control to Windows Mobile 7 application

    - by Jacob
    I know the bits just came out today, but one of the first things I want to do with the newly released Windows Mobile 7 SDK is put a map up on the screen and mess around. I've downloaded the latest version of the Silverlight Maps Control and added the references to my application. As a matter of fact, the VS 2010 design view of the MainPage.xaml shows the map control after adding the namespace and placing the control. I'm using the provided VS 2010 Express version that comes with the Win Mobile 7 SDK and have just used the New Project - Windows Phone Application template. When I try to build I get two warnings related to the Microsoft.Maps.MapControl dll's. Warning 1 The primary reference "Microsoft.Maps.MapControl, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" could not be resolved because it has an indirect dependency on the framework assembly "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e" which could not be resolved in the currently targeted framework. "Silverlight,Version=v4.0,Profile=WindowsPhone". To resolve this problem, either remove the reference "Microsoft.Maps.MapControl, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" or retarget your application to a framework version which contains "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e". Warning 2 The primary reference "Microsoft.Maps.MapControl.Common, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" could not be resolved because it has an indirect dependency on the framework assembly "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e" which could not be resolved in the currently targeted framework. "Silverlight,Version=v4.0,Profile=WindowsPhone". To resolve this problem, either remove the reference "Microsoft.Maps.MapControl.Common, Version=1.0.1.0, Culture=neutral, PublicKeyToken=498d0d22d7936b73, processorArchitecture=MSIL" or retarget your application to a framework version which contains "System.Windows.Browser, Version=2.0.5.0, Culture=neutral, PublicKeyToken=7cec85d7bea7798e". I'm leaning towards some way of adding the System.Windows.Browser to the targeted framework version. But I'm not even sure if that is possible. To be more specific; I'm looking for a way to get the Silverlight Maps Control up on a Windows Phone 7 series application. If possible. Thanks.

    Read the article

  • Using embedded resources in Silverlight (4) - other cultures not being compiled

    - by Andrei Rinea
    I am having a bit of a hard time providing localized strings for the UI in a small Silverlight 4 application. Basically I've put a folder "Resources" and placed two resource files in it : Statuses.resx Statuses.ro.resx I do have an enum Statuses : public enum Statuses { None, Working } and a convertor : public class StatusToMessage : IValueConverter { public object Convert(object value, Type targetType, object parameter, CultureInfo culture) { if (!Enum.IsDefined(typeof(Status), value)) { throw new ArgumentOutOfRangeException("value"); } var x = Statuses.None; return Statuses.ResourceManager.GetString(((Status)value).ToString(), Thread.CurrentThread.CurrentUICulture); } public object ConvertBack(object value, Type targetType, object parameter, CultureInfo culture) { throw new NotImplementedException(); } } in the view I have a textblock : <TextBlock Grid.Column="3" Text="{Binding Status, Converter={StaticResource StatusToMessage}}" /> Upon view rendering the converter is called but no matter what the Thread.CurrentThread.CurrentUICulture is set it always returns the default culture value. Upon further inspection I took apart the XAP resulted file, taken the resulted DLL file to Reflector and inspected the embedded resources. It only contains the default resource!! Going back to the two resource files I am now inspecting their properties : Build action : Embedded Resource Copy to output directory : Do not copy Custom tool : ResXFileCodeGenerator Custom tool namespace : [empty] Both resource (.resx) files have these settings. The .Designer.cs resulted files are as follows : Statuses.Designer.cs : //------------------------------------------------------------------------------ // <auto-generated> // This code was generated by a tool. // Runtime Version:4.0.30319.1 // // Changes to this file may cause incorrect behavior and will be lost if // the code is regenerated. // </auto-generated> //------------------------------------------------------------------------------ namespace SilverlightApplication5.Resources { using System; /// <summary> /// A strongly-typed resource class, for looking up localized strings, etc. /// </summary> // This class was auto-generated by the StronglyTypedResourceBuilder // class via a tool like ResGen or Visual Studio. // To add or remove a member, edit your .ResX file then rerun ResGen // with the /str option, or rebuild your VS project. [global::System.CodeDom.Compiler.GeneratedCodeAttribute("System.Resources.Tools.StronglyTypedResourceBuilder", "4.0.0.0")] [global::System.Diagnostics.DebuggerNonUserCodeAttribute()] [global::System.Runtime.CompilerServices.CompilerGeneratedAttribute()] internal class Statuses { // ... yadda-yadda Statuses.ro.Designer.cs [empty] I've taken both files and put them in a console application and they behave as expected in it, not like in this silverlight application. What is wrong?

    Read the article

  • Python, SWIG and other strange things

    - by wanderameise
    hey, I have a firmware for an USB module I can already control by visual C. Now I want to port this to python. for this I need the octopus library which is written in c. I found a file called octopus_wrap which was created by SWIG! then I found a makefile which says: python2.5: swig -python -outdir ./ ../octopus.i gcc -fPIC -c ../../liboctopus/src/octopus.c gcc -fPIC -c ../octopus_wrap.c -I /usr/include/python2.5 gcc -fPIC -shared octopus_wrap.o octopus.o /usr/lib/libusb.so -o _octopus.so python2.4: swig -python -outdir ./ ../octopus.i gcc -fPIC -c ../../liboctopus/src/octopus.c gcc -fPIC -c ../octopus_wrap.c -I /usr/include/python2.4 gcc -fPIC -shared octopus_wrap.o octopus.o /usr/lib/libusb.so -o _octopus.so win: gcc -fPIC -c ../../liboctopus/src/octopus.c -I /c/Programme/libusb-win32-device-bin-0.1.10.1/include gcc -fPIC -c octopus_wrap.c -I /c/Python25/libs -lpython25 -I/c/Python25/include -I /c/Programme/libusb-win32-device-bin-0.1.10.1/include gcc -fPIC -shared *.o -o _octopus.pyd -L/c/Python25/libs -lpython25 -lusb -L/c/Programme/libusb-win32-device-bin-0.1.10.1/lib/gcc clean: rm -f octopus* _octopus* install_python2.4: cp _octopus.so /usr/local/lib/python2.4/site-packages/ cp octopus.py /usr/local/lib/python2.4/site-packages/ install_python2.5: cp _octopus.so /usr/local/lib/python2.5/site-packages/ cp octopus.py /usr/local/lib/python2.5/site-packages/ I dont know how to handle this but as far as I can see octopus.py and _octopus.so are the resulting output files which are relevant to python right? luckily someone already did that and so I put those 2 files to my "python26/lib" folder (hope it doesnt matter if it´s python 2.5 or 2.6?!) So when working with the USB device the octopus.py is the library to work with! Importing this file makes several problems: >>> Traceback (most recent call last): File "C:\Users\ameise\My Dropbox\µC\AVR\OCTOPUS\octopususb-0.5\demos\python \blink_status.py", line 8, in <module> from octopus import * File "C:\Python26\lib\octopus.py", line 7, in <module> import _octopus ImportError: DLL load failed: module not found. and here´s the related line 7 : import _octopus So there´s a problem considering the .so file! What could be my next step? I know that´s a lot of confusing stuff but I hope anyone of you could bring some light in my mind! thy in advance

    Read the article

  • problem with two .NET threads and hardware access

    - by mack369
    I'm creating an application which communicates with the device via FT2232H USB/RS232 converter. For communication I'm using FTD2XX_NET.dll library from FTDI website. I'm using two threads: first thread continuously reads data from the device the second thread is the main thread of the Windows Form Application I've got a problem when I'm trying to write any data to the device while the receiver's thread is running. The main thread simply hangs up on ftdiDevice.Write function. I tried to synchronize both threads so that only one thread can use Read/Write function at the same time, but it didn't help. Below code responsible for the communication. Note that following functions are methods of FtdiPort class. Receiver's thread private void receiverLoop() { if (this.DataReceivedHandler == null) { throw new BackendException("dataReceived delegate is not set"); } FTDI.FT_STATUS ftStatus = FTDI.FT_STATUS.FT_OK; byte[] readBytes = new byte[this.ReadBufferSize]; while (true) { lock (FtdiPort.threadLocker) { UInt32 numBytesRead = 0; ftStatus = ftdiDevice.Read(readBytes, this.ReadBufferSize, ref numBytesRead); if (ftStatus == FTDI.FT_STATUS.FT_OK) { this.DataReceivedHandler(readBytes, numBytesRead); } else { Trace.WriteLine(String.Format("Couldn't read data from ftdi: status {0}", ftStatus)); Thread.Sleep(10); } } Thread.Sleep(this.RXThreadDelay); } } Write function called from main thread public void Write(byte[] data, int length) { if (this.IsOpened) { uint i = 0; lock (FtdiPort.threadLocker) { this.ftdiDevice.Write(data, length, ref i); } Thread.Sleep(1); if (i != (int)length) { throw new BackendException("Couldnt send all data"); } } else { throw new BackendException("Port is closed"); } } Object used to synchronize two threads static Object threadLocker = new Object(); Method that starts the receiver's thread private void startReceiver() { if (this.DataReceivedHandler == null) { return; } if (this.IsOpened == false) { throw new BackendException("Trying to start listening for raw data while disconnected"); } this.receiverThread = new Thread(this.receiverLoop); //this.receiverThread.Name = "protocolListener"; this.receiverThread.IsBackground = true; this.receiverThread.Start(); } The ftdiDevice.Write function doesn't hang up if I comment following line: ftStatus = ftdiDevice.Read(readBytes, this.ReadBufferSize, ref numBytesRead);

    Read the article

  • How to get NHProf reports in TeamCity running MSBUILD

    - by Jon Erickson
    I'm trying to get NHProf reports on my integration tests as a report in TeamCity I'm not sure how to get this set up correctly and my first attempts are unsuccessful. Let me know if there is any more information that would be helpful... I'm getting the following error, when trying to generate html reports with MSBUILD (which is being run by TeamCity) error MSB3073: The command "C:\CI\Tools\NHProf\NHProf.exe /CmdLineMode /File:"E:\CI\BuildServer\RMS-Winform\Group\dev\NHProfOutput.html" /ReportFormat:Html" exited with code -532459699 I tell TeamCity to run MSBUILD w/ CIBuildWithNHProf target The command line parameters that I pass from TeamCity are... /property:NHProfExecutable=%system.NHProfExecutable%;NHProfFile=%system.teamcity.build.checkoutDir%\NHProfOutput.html;NHProfReportFormat=Html The portion of my MSBUILD script that runs my tests is as follows... <UsingTask TaskName="NUnitTeamCity" AssemblyFile="$(teamcity_dotnet_nunitlauncher_msbuild_task)"/> <!-- Set Properties --> <PropertyGroup> <Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration> <Platform Condition=" '$(Platform)' == '' ">x86</Platform> <NHProfExecutable></NHProfExecutable> <NHProfFile></NHProfFile> <NHProfReportFormat></NHProfReportFormat> </PropertyGroup> <!-- Test Database --> <Target Name="DeployDatabase"> <!-- ... --> </Target> <!-- Database Used For Integration Tests --> <Target Name="DeployTestDatabase"> <!-- ... --> </Target> <!-- Build All Projects --> <Target Name="BuildProjects"> <MSBuild Projects="..\MySolutionFile.sln" Targets="Build"/> </Target> <!-- Stop NHProf --> <Target Name="NHProfStop"> <Exec Command="$(NHProfExecutable) /Shutdown" /> </Target> <!-- Run Unit/Integration Tests --> <Target Name="RunTests"> <CreateItem Include="..\**\bin\debug\*Tests.dll"> <Output TaskParameter="Include" ItemName="TestAssemblies" /> </CreateItem> <NUnitTeamCity Assemblies="@(TestAssemblies)" NUnitVersion="NUnit-2.5.3"/> </Target> <!-- Start NHProf --> <Target Name="NHProfStart"> <Exec Command="$(NHProfExecutable) /CmdLineMode /File:&quot;$(NHProfFile)&quot; /ReportFormat:$(NHProfReportFormat)" /> </Target> <Target Name="CIBuildWithNHProf" DependsOnTargets="BuildProjects;DeployTestDatabase;NHProfStart;RunTests;NHProfStop;DeployDatabase"> </Target>

    Read the article

< Previous Page | 190 191 192 193 194 195 196 197 198 199 200 201  | Next Page >