Search Results

Search found 82 results on 4 pages for 'alarms'.

Page 2/4 | < Previous Page | 1 2 3 4  | Next Page >

  • How could I manage Google Adsense to approve my Web App? It keeps denying it

    - by Javierfdr
    Google adsense keeps denying my app from having ads, because of an "insufficient content" issue. I manage a Web Application that allows the users to set Youtube Videos as Alarm Clocks. It includes an in-site Youtube search to retrieve videos from user queries and lists the users alarms. The site has a good traffic (500 users per day), is currently promoted by Google in Google Chrome Webstore, and the ajax requests are crawlable, following Google's guidelines (https://developers.google.com/webmasters/ajax-crawling/). Although I understand there is not much content, beyond the user-generated, I really don't what else should I include in the site. Perhaps adding contact and about pages, and maybe another section would increase the navigation. Google argues I need a "fully launched and functioning site, allowing users to navigate throughout your site with a menu, sitemap, or appropiate links". They also ask for "full sentences or paragraphs" Isn't a Google Adsense solutions for Web Applications? Would all the web-apps have to include useless navigable subpages?

    Read the article

  • Alarm not working if application gets killed

    - by Tobia Loschiavo
    Hi, I am trying to use an alarm to set my widget layout after some minutes. Everything works correctly in normal situation but, if I try to delete the process of my application, simulating a system kill, after the alarm is set, then no alarm is executed. Why? From documentation it seems that alarms are executed by AlarmManager service...so it should work. Thanks Tobia Loschiavo

    Read the article

  • having json issues..getting this in firebug--missing ] after element list

    - by faizal
    hi all this is my json object..everything seems to be fin e but dunnkow why i am seeing this--missing ] after element list can somebody help.,.here is y json {"rows": [{"type": "fft_vel","axis": "x","pwrhgh": 7.44475138121547E-02,"pwrlow": 2.35267034990792E-02,"hzlow": 244.827586206897,"hzhgh": 506.896551724138,"dataid": 0,"id": 467,"name": "2008-02-08 14:24:22 - creating first active alarms testing","title": "RMS displacement alert on Pump 11 Sensor 2","description": "An RMS displacement value of 0.04495 inches was recorded on Pump 11 Sensor 2 on 2\u002F8\u002F2008. This is between the RMS displacement alert levels of 0.0442 inches and 0.12 inches.","time_stamp": "2\u002F8\u002F2008 2:24:22 PM","sensor_id": 550003281}]}

    Read the article

  • Windows Mobile Sounds Not using Device Speaker

    - by Vaccano
    I have bunch of Symbol MC 70 devices. They run Windows Mobile 5. Most of these work just fine, but I have one that is sending the sounds (alarms and such) to the phone rather than the speaker on the device. (The sounds play in the speaker used for listening to a phone call) Does anyone know how to route this back to the actual phone speaker?

    Read the article

  • Oracle Solaris Cluster 4.2 Event and its SNMP Interface

    - by user12609115
    Background The cluster event SNMP interface was first introduced in Oracle Solaris Cluster 3.2 release. The details of the SNMP interface are described in the Oracle Solaris Cluster System Administration Guide and the Cluster 3.2 SNMP blog. Prior to the Oracle Solaris Cluster 4.2 release, when the event SNMP interface was enabled, it would take effect on WARNING or higher severity events. The events with WARNING or higher severity are usually for the status change of a cluster component from ONLINE to OFFLINE. The interface worked like an alert/alarm interface when some components in the cluster were out of service (changed to OFFLINE). The consumers of this interface could not get notification for all status changes and configuration changes in the cluster. Cluster Event and its SNMP Interface in Oracle Solaris Cluster 4.2 The user model of the cluster event SNMP interface is the same as what was provided in the previous releases. The cluster event SNMP interface is not enabled by default on a freshly installed cluster; you can enable it by using the cluster event SNMP administration commands on any cluster nodes. Usually, you only need to enable it on one of the cluster nodes or a subset of the cluster nodes because all cluster nodes get the same cluster events. When it is enabled, it is responsible for two basic tasks. • Logs up to 100 most recent NOTICE or higher severity events to the MIB. • Sends SNMP traps to the hosts that are configured to receive the above events. The changes in the Oracle Solaris Cluster 4.2 release are1) Introduction of the NOTICE severity for the cluster configuration and status change events.The NOTICE severity is introduced for the cluster event in the 4.2 release. It is the severity between the INFO and WARNING severity. Now all severities for the cluster events are (from low to high) • INFO (not exposed to the SNMP interface) • NOTICE (newly introduced in the 4.2 release) • WARNING • ERROR • CRITICAL • FATAL In the 4.2 release, the cluster event system is enhanced to make sure at least one event with the NOTICE or a higher severity will be generated when there is a configuration or status change from a cluster component instance. In other words, the cluster events from a cluster with the NOTICE or higher severities will cover all status and configuration changes in the cluster (include all component instances). The cluster component instance here refers to an instance of the following cluster componentsnode, quorum, resource group, resource, network interface, device group, disk, zone cluster and geo cluster heartbeat. For example, pnode1 is an instance of the cluster node component, and oracleRG is an instance of the cluster resource group. With the introduction of the NOTICE severity event, when the cluster event SNMP interface is enabled, the consumers of the SNMP interface will get notification for all status and configuration changes in the cluster. A thrid-party system management platform with the cluster SNMP interface integration can generate alarms and clear alarms programmatically, because it can get notifications for the status change from ONLINE to OFFLINE and also from OFFLINE to ONLINE. 2) Customization for the cluster event SNMP interface • The number of events logged to the MIB is 100. When the number of events stored in the MIB reaches 100 and a new qualified event arrives, the oldest event will be removed before storing the new event to the MIB (FIFO, first in, first out). The 100 is the default and minimum value for the number of events stored in the MIB. It can be changed by setting the log_number property value using the clsnmpmib command. The maximum number that can be set for the property is 500. • The cluster event SNMP interface takes effect on the NOTICE or high severity events. The NOTICE severity is also the default and lowest event severity for the SNMP interface. The SNMP interface can be configured to take effect on other higher severity events, such as WARNING or higher severity events by setting the min_severity property to the WARNING. When the min_severity property is set to the WARNING, the cluster event SNMP interface would behave the same as the previous releases (prior to the 4.2 release). Examples, • Set the number of events stored in the MIB to 200 # clsnmpmib set -p log_number=200 event • Set the interface to take effect on WARNING or higher severity events. # clsnmpmib set -p min_severity=WARNING event Administering the Cluster Event SNMP Interface Oracle Solaris Cluster provides the following three commands to administer the SNMP interface. • clsnmpmib: administer the SNMP interface, and the MIB configuration. • clsnmphost: administer hosts for the SNMP traps • clsnmpuser: administer SNMP users (specific for SNMP v3 protocol) Only clsnmpmib is changed in the 4.2 release to support the aforementioned customization of the SNMP interface. Here are some simple examples using the commands. Examples: 1. Enable the cluster event SNMP interface on the local node # clsnmpmib enable event 2. Display the status of the cluster event SNMP interface on the local node # clsnmpmib show -v 3. Configure my_host to receive the cluster event SNMP traps. # clsnmphost add my_host Cluster Event SNMP Interface uses the common agent container SNMP adaptor, which is based on the JDMK SNMP implementation as its SNMP agent infrastructure. By default, the port number for the SNMP MIB is 11161, and the port number for the SNMP traps is 11162. The port numbers can be changed by using the cacaoadm. For example, # cacaoadm list-params Print all changeable parameters. The output includes the snmp-adaptor-port and snmp-adaptor-trap-port properties. # cacaoadm set-param snmp-adaptor-port=1161 Set the SNMP MIB port number to 1161. # cacaoadm set-param snmp-adaptor-trap-port=1162 Set the SNMP trap port number to 1162. The cluster event SNMP MIB is defined in sun-cluster-event-mib.mib, which is located in the /usr/cluster/lib/mibdirectory. Its OID is 1.3.6.1.4.1.42.2.80, that can be used to walk through the MIB data. Again, for more detail information about the cluster event SNMP interface, please see the Oracle Solaris Cluster 4.2 System Administration Guide. - Leland Chen 

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Should EC2 server self register or have admin server

    - by hortitude
    I'm creating AWS servers using chef. I am also planning on enabling auto-scaling. While we have automatic monitoring setup already (server density or nagios etc), I was also going to setup the cloud watch alarm for the status check on the server. This led me down the path of trying to decide whether to install the ec2-command-line tools on the server itself (which then requires me to install java on the servers -- despite no other need for Java in our environment) or to possible have an "admin" box that will check periodically for servers and make sure they have their alarms set. I expect this paradigm to carry over to other things we want to configure (perhaps ensuring that termination protection is setup on production servers?). Any thoughts as to why to go one direction or another?

    Read the article

  • Monitoring over Time with Nagios: How?

    - by David
    Nagios in its standard usage monitors with point-in-time checks: either something is - or is not - true. Other tools like SGI's PCP, HP's MeasureWare, and SEC provide monitoring over time - monitoring things like average disk access time over the last five minutes, or other similar items. Is there anything like this for Nagios? I'm already running NDOUtils, which seems like a natural source for such data. I'd like to have something that would monitor and fire off alarms based on a time-based check using historical data. Is there anything like this for Nagios?

    Read the article

  • Remove Outlook 2007 Calendar from Calendars List

    - by nmuntz
    In our company, we use personal folders with Outlook 2007 and make it the default method of downloading messages to keep our mailbox size on the server side small. Under calendar view, i see both calendars, my personal folder one and my server one. How can I remove from the list of calendars my server one since I do not use that one and it only creates confusion and problems such as adding entries onto that one instead of the other or disabling one and not getting alarms? I tried googling on it and read there is a utility to do that but couldn't find the name of it. Thanks in advance for your help.

    Read the article

  • Amazon EC2 Web server in Load Balancer gives 503

    - by dale
    we've been running our web servers at Amazon with load balancer and auto-scaling for over a year with no problem. All of a sudden today the request began to get aborted with the error: 503 ... Backend server is at capacity The web servers are at 1% CPU and no other alarms trigger. We use Amazons load balancer and nginx. Lots of requests like this are showing up in the access_log. 10.246.114.93 - - [05/Jun/2014:20:16:09 +0000] "-" 400 0 "-" "-" 10.246.114.93 - - [05/Jun/2014:20:16:09 +0000] "-" 400 0 "-" "-" 10.246.114.93 - - [05/Jun/2014:20:16:09 +0000] "-" 400 0 "-" "-" 10.246.114.93 - - [05/Jun/2014:20:16:09 +0000] "-" 400 0 "-" "-" 10.246.114.93 - - [05/Jun/2014:20:16:10 +0000] "-" 400 0 "-" "-" 10.246.114.93 - - [05/Jun/2014:20:16:10 +0000] "-" 400 0 "-" "-" 10.246.114.93 - - [05/Jun/2014:20:16:10 +0000] "-" 400 0 "-" "-" 10.229.15.214 - - [05/Jun/2014:20:16:10 +0000] "-" 400 0 "-" "-" 10.229.15.214 - - [05/Jun/2014:20:16:10 +0000] "-" 400 0 "-" "-" Any thoughts?

    Read the article

  • Applescript create event in calendar, how do I remove the default alert?

    - by zero0cool
    Running 10.8 Mountain Lion, I'm trying to create a new event with Applescript like this: set theDate to (current date) tell application "Calendar" tell calendar "Calendar" set timeString to time string of theDate set newEvent to make new event at end with properties {description:"Last Backup", summary:"Last Backup " & timeString, location:"To a local unix system", start date:theDate, end date:theDate + 15 * minutes, allday event:false, status:confirmed} tell newEvent delete every display alarm delete every sound alarm delete every mail alarm delete every open file alarm end tell end tell end tell However, this does not remove the default Calendar alert which one can set through Calendar preferences (30 minutes prior in my case). How do I create an event with no alarms at all through Applescript?

    Read the article

  • Receiving a notification on a Cluster Group Failover

    - by Diego
    Hi all, I have several Windows Cluster set up and I have the need of keeping track of failovers. I'd need to receive a notification of sort whenever a group fails over. I've seen some examples around, but I can't rely on the approach of just sending a message whenever the resources are stopped/restarted as it would generate too many false alarms. In few words, I need to be notified if and only if the group really fails over. I was thinking that probably the best way is monitoring the System Event Log, but, if possible, I'd prefer not having to write a script/program from scratch for this issue. Is there any script/product that already does it? Thanks.

    Read the article

  • Oracle Coherence & Oracle Service Bus: REST API Integration

    - by Nino Guarnacci
    This post aims to highlight one of the features found in Oracle Coherence which allows it to be easily added and integrated inside a wider variety of projects.  The features in question are the REST API exposed by the Coherence nodes, with which you can interact in the wider mode in memory data grid.Oracle Coherence and Oracle Service Bus are natively integrated through a feature found in the Oracle Service Bus, which allows you to use the coherence grid cache during the configuration phase of a business service. This feature allows you to use an intermediate layer of cache to retrieve the answers from previous invocations of the same service, without necessarily having to invoke the real business service again. Directly from the web console of Oracle Service Bus, you can decide the policies of eviction of the objects / answers and define the discriminating parameters that identify their uniqueness.The coherence REST APIs, however, allow you to integrate both products for other necessities enabling realization of new architectures design.  Consider coherence’s node as a simple service which interoperates through the stardard services and in particular REST (with JSON and XML). Thinking of coherence as a company’s shared service, able to have an implementation of a centralized “map and reduce” which you can access  by a huge variety of protocols (transport and envelopes).An amazing step forward for those who still imagine connectors and code. This type of integration does not require writing custom code or complex implementation to be self-supported. The added value is made unique by the incredible value of both products independently, and still more out of their simple and robust integration.As already mentioned this scenario discovers a hidden new door behind the columns of these two products. The door leads to new ideas and perspectives for enterprise architectures that increasingly wink to next-generation applications: simple and dynamic, perhaps towards the mobile and web 2.0.Below, a small and simple demo useful to demonstrate how easily is to integrate these two products using the Coherence REST API. This demo is also intended to imagine new enterprise architectures using this approach.The idea is to create a centralized system of alerting, fed easily from any company’s application, regardless of the technology with which they were built . Then use a representation standard protocol: RSS, using a service exposed by the service bus; So you can browse and search only the alerts that you are interested on, by category, author, title, date, etc etc.. The steps needed to implement this system are very simple and very few. Here they are listed below and described to be easily replicated within your environment. I would remind you that the demo is only meant to demonstrate how easily is to integrate Oracle Coherence and the Oracle Service Bus, and stimulate your imagination to new technological approaches.1) Install the two products: In this demo used (if necessary, consult the installation guides of 2 products)  - Oracle Service Bus ver. 11.1.1.5.0 http://www.oracle.com/technetwork/middleware/service-bus/downloads/index.html - Oracle Coherence ver. 3.7.1 http://www.oracle.com/technetwork/middleware/coherence/downloads/index.html 2) Because you choose to create a centralized alerting system, we need to define a structure type containing some alerting attributes useful to preserve and organize the information of the various alerts sent by the different applications. Here, then it was built a java class named Alert containing the canonical properties of an alarm information:- Title- Description- System- Time- Severity 3) Therefore, we need to create two configuration files for the coherence node, in order to save the Alert objects within the grid, through the rest/http protocol (more than the native API for Java, C + +, C,. Net). Here are the two minimal configuration files for Coherence:coherence-rest-config.xml resty-server-config.xml This minimum configuration allows me to use a distributed cache named "alerts" that can  also be accessed via http - rest on the host "localhost" over port "8080", objects are of type “oracle.cohsb.Alert”. 4) Below  a simple Java class that represents the type of alert messages: 5) At this point we just need to startup our coherence node, able to listen on http protocol to manage the “alerts” cache, which will receive incoming XML or JSON objects of type Alert. Remember to include in the classpath of the coherence node, the Alert java class and the following coherence libraries and configuration files:  At this point, just run the coherence class node “com.tangosol.net.DefaultCacheServer”advising you to set the following parameters:-Dtangosol.coherence.log.level=9 -Dtangosol.coherence.log=stdout -Dtangosol.coherence.cacheconfig=[PATH_TO_THE_FILE]\resty-server-config.xml 6) Let's create a procedure to test our configuration of Coherence and in order to insert some custom alerts in our cache. The technology with which you want to achieve this functionality is fully not considerable: Javascript, Python, Ruby, Scala, C + +, Java.... Because the protocol to communicate with Coherence is simply HTTP / JSON or XML. For this little demo i choose Java: A method to send/put the alert to the cache: A method to query and view the content of the cache: Finally the main method that execute our methods:  No special library added in the classpath for our class (json struct static defined), when it will be executed, it asks some information such as title, description,... in order to compose and send an alert to the cache and then it will perform an inquiry, to the same cache. At this point, a good exercise at this point, may be to create the same procedure using other technologies, such as a simple html page containing some JavaScript code, and then using Python, Ruby, and so on.7) Now we are ready to start configuring the Oracle Service Bus in order to integrate the two products. First integrate the internal alerting system of Oracle Service Bus with our centralized alerting system based on coherence node. This ensures that by monitoring, or directly from within our Proxy Message Flow, we can throw alerts and save them directly into the Coherence node. To do this I choose to use the jms technology, natively present inside the Oracle Weblogic / Service Bus. Access to the Oracle WebLogic Administration console and create and configure a new JMS connection factory and a new jms destination (queue). Now we should create a new resource of type “alert destination” within our Oracle Service Bus project. The new “alert destination” resource should be configured using the newly created connection factory jms and jms destination. Finally, in order to withdraw the message alert enqueued in our JMS destination and send it to our coherence node, we just need to create a new business service and proxy service within our Oracle Service Bus project.Our business service is responsible for sending a message to our REST service Coherence using as a method action: PUT Finally our proxy service have to collect all messages enqueued on the destination, execute an xquery transformation on those messages  in order to translate them into valid XML / alert objects useful to be sent to our coherence service, through the newly created business service. The message flow pipeline containing the xquery transformation: Incredibly,  we just did a basic first integration between the native alerting system of Oracle Service Bus and our centralized alerting system by simply configuring our coherence node without developing anything.It's time to test it out. To do this I create a proxy service able to generate an alert using our "alert destination", whenever the proxy is invoked. After some invocation to our proxy that generates fake alerts, we could open an Internet browser and type the URL  http://localhost: 8080/alerts/  so we could see what has been inserted within the coherence node. 8) We are ready for the final step.  We would create a new message flow, that can be used to search and display the results in standard mode. To do this I choosen the standard representation of RSS, to display a formatted result on a huge variety of devices such as readers for the iPhone and Android. The inquiry may be defined already at the time of the request able to return only feed / items related to our needs. To do this we need to create a new business service, a new proxy service, and finally a new XQuery Transformation to take care of translating the collection of alerts that will be return from our coherence node in a nicely formatted RSS standard document.So we start right from this resource (xquery), which has the task of transforming a collection of alerts / xml returned from the node coherence in a type well-formatted feed RSS 2.0 our new business service that will search the alerts on our coherence node using the Rest API. And finally, our last resource, the proxy service that will be exposed as an RSS / feeds to various mobile devices and traditional web readers, in which we will intercept any search query, and transform the result returned by the business service in an RSS feed 2.0. The message flow with the transformation phase (Alert TO Feed Items): Finally some little tricks to follow during the routing to the business service, - check for any queries present in the url to require a subset of alerts  - the http header "Accept" to help get an answer XML instead of JSON: In our little demo we also static added some coherence parameters to the request:sort=time:desc;start=0;count=100I would like to get from Coherence that the results will be sorted by date, and starting from 1 up to a maximum of 100.Done!!Just incredible, our centralized alerting system is ready. Inheriting all the qualities and capabilities of the two products involved Oracle Coherence & Oracle Service Bus: - RASP (Reliability, Availability, Scalability, Performance)Now try to use your mobile device, or a normal Internet browser by accessing the RSS just published: Some urls you may test: Search for the last 100 alerts : http://localhost:7001/alarmsSearch for alerts that do not have time set to null (time is not null):http://localhost:7001/alarms?q=time+is+not+nullSearch for alerts that the system property is “Web Browser” (system = ‘Web Browser’):http://localhost:7001/alarms?q=system+%3D+%27Web+Browser%27Search for alerts that the system property is “Web Browser” and the severity property is “Fatal” and the title property contain the word “Javascript”  (system = ‘Web Broser’ and severity = ‘Fatal’ and title like ‘%Javascript%’)http://localhost:8080/alerts?q=system+%3D+%27Web+Browser%27+AND+severity+%3D+%27Fatal%27+AND+title+LIKE+%27%25Javascript%25%27 To compose more complex queries about your need I would suggest you to read the chapter in the coherence documentation inherent the Cohl language (Coherence Query Language) http://download.oracle.com/docs/cd/E24290_01/coh.371/e22837/api_cq.htm . Some useful links: - Oracle Coherence REST API Documentation http://download.oracle.com/docs/cd/E24290_01/coh.371/e22839/rest_intro.htm - Oracle Service Bus Documentation http://download.oracle.com/docs/cd/E21764_01/soa.htm#osb - REST explanation from Wikipedia http://en.wikipedia.org/wiki/Representational_state_transfer At this URL could be downloaded the whole materials of this demo http://blogs.oracle.com/slc/resource/cosb/coh-sb-demo.zip Author: Nino Guarnacci.

    Read the article

  • lm-sensor and cpu temperatures

    - by nalsanj
    i am on ubuntu Precise Pangolin. The processor is Intel i3. a desktop. i installed lm-sensors and below is the report "sensors" gave coretemp-isa-0000 Adapter: ISA adapter Core 0: +30.0°C (high = +89.0°C, crit = +105.0°C) Core 2: +33.0°C (high = +89.0°C, crit = +105.0°C) w83627dhg-isa-0a10 Adapter: ISA adapter Vcore: +0.93 V (min = +0.00 V, max = +1.74 V) in1: +0.75 V (min = +1.99 V, max = +1.99 V) ALARM AVCC: +3.36 V (min = +2.98 V, max = +3.63 V) +3.3V: +3.36 V (min = +2.98 V, max = +3.63 V) in4: +1.30 V (min = +0.90 V, max = +1.77 V) in5: +0.76 V (min = +1.15 V, max = +0.90 V) ALARM in6: +1.06 V (min = +0.94 V, max = +2.03 V) 3VSB: +3.36 V (min = +2.98 V, max = +3.63 V) Vbat: +3.36 V (min = +2.70 V, max = +3.30 V) ALARM fan1: 0 RPM (min = 3515 RPM, div = 128) ALARM fan2: 0 RPM (min = 10546 RPM, div = 128) ALARM fan3: 0 RPM (min = 10546 RPM, div = 128) ALARM fan5: 0 RPM (min = 10546 RPM, div = 128) ALARM temp1: +39.0°C (high = -121.0°C, hyst = +9.0°C) ALARM sensor = diode temp2: +39.0°C (high = +80.0°C, hyst = +75.0°C) sensor = diode temp3: +127.0°C (high = +80.0°C, hyst = +75.0°C) ALARM sensor = thermistor cpu0_vid: +2.050 V intrusion0: OK radeon-pci-0100 Adapter: PCI adapter temp1: +70.5°C The fans sensors are detecting 0 RPM and some temperatures are out of range - the ALARMs above but i dont understand it very well. Can someone help out?

    Read the article

  • CodePlex Daily Summary for Sunday, October 20, 2013

    CodePlex Daily Summary for Sunday, October 20, 2013Popular ReleasesKerbalAlarmClock: v2.6.1.0 Release: Version 2.6.1.0 Recompiled it for 0.21 Added Crew Alarms (track Kerbal rather than Vessel) Added Distance Target Alarms - distance from target vessel or altitude above planet Added Launch Rendezvous Alarm (under Ascending/Descending Node for Landed craft) - MechJeb2 code - thanks r4m0n Allow restoration of Nodes that you have passed (useful for interplanetary burns) Added missing Dres Transfer Model data - thanks Voneiden Added view only version of Alarm clock to both Space Center...MSBuild Extension Pack: October 2013: Release Blog Post The MSBuild Extension Pack October 2013 release provides a collection of over 480 MSBuild tasks. A high level summary of what the tasks currently cover includes the following: System Items: Active Directory, Certificates, COM+, Console, Date and Time, Drives, Environment Variables, Event Logs, Files and Folders, FTP, GAC, Network, Performance Counters, Registry, Services, Sound Code: Assemblies, AsyncExec, CAB Files, Code Signing, DynamicExecute, File Detokenisation, GUI...VG-Ripper & PG-Ripper: VG-Ripper 2.9.49: changes NEW: Added Support for "ImageTeam.org links NEW: Added Support for "ImgNext.com" links NEW: Added Support for "HostUrImage.com" links NEW: Added Support for "3XVintage.com" linksMedia Companion: Media Companion MC3.583b: As before release but fixed for no movie poster sourcesNew* Both - Added 'An' as option to ignore in title * Movie - Renaming - added %Z - Sorttitle to Legend * Movie - Renaming - added %O - Audio Channels to Legend * Movie - Remove a poster source from priority list. Reset List back to defaults. * Made Media Companion truly portable application. Fixed* Movie - browse for Poster Or Fanart, allows for jpg, tbn, png and bmp images * Movie - Alt Fanart Browser - Url or Browse window now fully...MoreTerra (Terraria World Viewer): MoreTerra 1.11.3.1: Release 1.11.3.1 ================ = New Features = ================ Added markers for Copper Cache, Silver Cache and the Enchanted Sword. ============= = Bug Fixes = ============= Use Official Colors now no longer tries to change the Draw Wires option instead. World reading was breaking for people with a stock 1.2 Terraria version. Changed world name reading so it does not crash the program if you load MoreTerra while Terraria is saving the world. =================== = Feature Removal = =...patterns & practices - Windows Azure Guidance: Cloud Design Patterns: 1st drop of Cloud Design Patterns project. It contains 14 patterns with 6 related guidance.Player Framework by Microsoft: Player Framework for Windows and WP (v1.3): Includes all changes in v1.3 beta 1 and v1.3 beta 2 Support for Windows 8.1 RTM and VS2013 RTM Xaml: New property: AutoLoadPluginTypes to help control which stock plugins are loaded by default (requires AutoLoadPlugins = true). Support for SystemMediaTransportControls on Windows 8.1 JS: Support for visual markers in the timeline. JS: Support for markers collection and markerreached event. JS: New ChaptersPlugin to automatically populate timeline with chapter tracks. JS: Audio an...Json.NET: Json.NET 5.0 Release 8: Fix - Fixed not writing string quotes when QuoteName is falsePowerShell Community Extensions: 3.1 Production: PowerShell Community Extensions 3.1 Release NotesOct 17, 2013 This version of PSCX supports Windows PowerShell 3.0 and 4.0 See the ReleaseNotes.txt download above for more information.SQL Power Doc: Version 1.0.2.1: Misc. bug fixes Added logic to resolve members of a Windows Group server login Added columns to Excel workbooks to show definitions for server permissions, server roles, database permissions, and database rolesSocial Network Importer for NodeXL: SocialNetImporter(v.1.9): This new version includes: - Download latest status update and use it as vertex tooltip - Limit the timelines to parse to me, my friends or both - Fixed some reported bugs about the fan page and group importer - Fixed the login bug reported latelyTerrariViewer: TerrariViewer v7.1 [Terraria Inventory Editor]: You can now backspace in number fields Items added in 1.2.0.3 no longer corrupt player files Buff durations capped at 9999999 Item stacks capped at 9999999 Version info added Prefix IDs corrected Shoe and Eye color box are now properly clickable Moved Bank and Safe into their own tab Users will now be notified of new updatesPython Tools for Visual Studio: 2.0: PTVS 2.0 We’re pleased to announce the release of Python Tools for Visual Studio 2.0 RTM. Python Tools for Visual Studio (PTVS) is an open-source plug-in for Visual Studio which supports programming with the Python language. PTVS supports a broad range of features including CPython/IronPython, Edit/Intellisense/Debug/Profile, Cloud, IPython, and cross platform and cross language debugging support. QUICK VIDEO OVERVIEW For a quick overview of the general IDE experience, please watch this v...CS-Script for Notepad++ (C# intellisense and code execution): Release v1.0.8.2: Solved scrolling problem after DocumentFormatting Implemented "format as you type" --- To avoid the DLLs getting locked by OS use MSI file for the installation.LINQ to Twitter: LINQ to Twitter v2.1.09: Supports .NET 3.5, .NET 4.0, .NET 4.5, Silverlight 4.0, Windows Phone 7.1, Windows Phone 8, Client Profile, Windows 8, and Windows Azure. 100% Twitter API coverage. Also supports Twitter API v1.1! Also on NuGet.Sandcastle Help File Builder: SHFB v1.9.8.0 with Visual Studio Package: General InformationIMPORTANT: On some systems, the content of the ZIP file is blocked and the installer may fail to run. Before extracting it, right click on the ZIP file, select Properties, and click on the Unblock button if it is present in the lower right corner of the General tab in the properties dialog. This new release contains bug fixes and feature enhancements. There are some potential breaking changes in this release as some features of the Help File Builder have been moved into...C++ REST SDK (codename "Casablanca"): C++ REST SDK 1.3.0: This release fixes multiple customer reported issues as well as the following: Full support for Dev12 binaries and project files Full support for Windows XP New sample highlighting the Client and Server APIs : BlackJack Expose underlying native handle to set custom options on http_client Improvements to Listener Library Note: Dev10 binaries have been dropped as of this release, however the Dev10 project files are still available in the Source CodeAD ACL Scanner: 1.3.2: Minor bug fixed: Powershell 4.0 will report: Select—Object: Parameter cannot be processed because the parameter name p is ambiguous.Fast YouTube Downloader: YouTube Downloader 2.2.0: YouTube Downloader 2.2.0VidCoder: 1.5.8 Beta: Added hardware acceleration options: Bicubic OpenCL scaling algorithm, QSV decoding/encoding and DXVA decoding. Updated HandBrake core to SVN 5834. Updated VidCoder setup icon. Fixed crash when choosing the mp4v2 container on x86 and opening on x64. Warning: the hardware acceleration features require specific hardware or file types to work correctly: QSV: Need an Intel processor that supports Quick Sync Video encoding, with a monitor hooked up to the Intel HD Graphics output and the lat...New ProjectsAdd2Nums: Add2Nums is a VB.NET project that takes 2 numbers, computes their sum and outputs the result. Developed by Justin Mifsud as part of Assignment 1 (7COM0152)Athir: GPAO El_AthirCS-MIC - C# Math Input Control: CS-MIC is a .NET library written in C# designed to give developers easy access to expression parsing.HLS Video Player: An open source over-the-network video player for HLS (Hinkle Light Show)Project Stark: This is a secret project available only to the project owners for the time being.Run ++: Run Plus Plus is a tool that enables you to custom the commands in the "Run" dialog.SimpleAddition: This is a simple ASP.NET in VB.NET page that allows users to enter 2 numbers, and display their sum. SWE 681 Go Fish: Project

    Read the article

  • Delphi 2010 Error Insight incorrectly flags "Undeclared Identifier"

    - by user257188
    In D2010, Error Insight is incorrectly underlining in red types like "TOpenDialog" (even though my unit and project's uses both include Dialogs). Also, in my method TMyFrame.Foo, it fails the same way by flagging a reference to a VCL component in my TMyFrame -- even though Foo and the component are both part of TMyFrame. SO suggested I read several threads on this subject. One mentions a D2009 fix for this. Is there a D2010 fix? Other postings have suggested that Error Insight yields too many false alarms and should just be turned off. Any suggestions?

    Read the article

  • Inform Activity from a BroadcastReceiver ONLY if it is in the foreground

    - by Zordid
    Hi there! Maybe it's easy, but I couldn't really figure this out right so far... I got a BroadcastReceiver waiting to get triggered by the AlarmMangager - this works fine. Now: because the event, if it occurs, needs to refresh some elements on screen of the main Activity, I would like to send an Intent from that background BroadcastReceiver to my Activity - but only if it is currently in the foreground, aka active. If it is not running or not visible, I don't care - and the last thing I want to do is start the Activity by my intent! I handle repainting of the views in my onResume method, so I don't care at all. Any hints on how to do that? Thanks! EDIT: my BroadcastReceiver is waiting for alarms that must be notified to the user. So, it must be there and declared in the manifest. The problem is: it will have to decide whether the mentioned Activity is currently up in front or not.

    Read the article

  • NSTimer to fire while device is locked

    - by edie
    Hi, I'm currently creating an alarm. I use NSTimer to schedule my alarms. My problem is when the device was put into locked mode my NSTimer doesn't fire. I think that the NSTimer will not fire because my app goes to suspended state when it is lock. Can you help me find a solution to my problem? I've found some topics about UIBackgroundModes, but I don't know how it will help me. Thanks.. The problem in UILocalNotification is when the device was in silent, the sound will not be hear. My implementation was I'm using NSTimer to fire an alarm when the app is in foreground or device is locked but app currently running. When the applicationDidEnterBackground: is called I schedule the UILocalNotification as the alarm.

    Read the article

  • How do I give a jQuery Element a fixed position on the page. In other words absolute positioning of a jQuery element.

    - by Stephanie
    <script type="text/javascript"> $(function() { $('a.StackedSystem').hover(function(e) { var html = '<div id="StackedSysteminfo">'; html += '<div id="StackedSystemTxt"> ETTER utilizes the latest technologies for our booster systems, including PLC-Based controls complete with touch-screen panel user interfaces (HMI). The base package includes the gray scale screen as shown; color screens are also available. The PLC not only provides a cleaner interface but provides additional features like automatic logging and time/date stamping of all alarms and shut-downs. Great for trouble-shooting.'; html += ''; $('body').append(html).children('#info').hide().fadeIn(400); }, function() { $('#StackedSysteminfo').remove(); }); });

    Read the article

  • How to schedule an alarm so that the intent is broadcast everytime the date changes?

    - by rogerstone
    I want to schedule an alarm which throws an intent when the date changes. I know that this would do this the job alarms.setRepeating(AlarmManager.RTC_WAKEUP,triggerAtTime, interval,alarmIntent); But what is confusing me is what to put in the triggerAtTime and the interval.It says System.currentTimeMillis() timebase. I might be installing the app on any day so the TriggerAtTime should be midnight of that day and the interval would be 24 hours from there on. How can I acheive this.Can someone tell me what to put in TriggerAtTime and interval in the required format. Thanks

    Read the article

  • Getting values from datagrid view column to list<>

    - by EvanRyan
    My main form in my application has a datagrid view that can have 1 to many user selected inputs. Column 8 of this grid is for the user to input "time in minutes." I have a separate class where I have built a timer that counts down from whatever time the user specifies down to 0. What I need is to create a series of alarms that go off as the timer counts down that are triggered by the user input values in column 8 of my datagrid. I think the best way to do this is to build a list< from the values in the datagrid. I for whatever reason can't quite figure out how to get the values from the datagrid in to a list< in my other class. Hopefully I explained in a way that makes sense.

    Read the article

  • Programmable Home Security Alarm [closed]

    - by stej
    I don't ask for recommendation! (just wanted to say that; anyway it doesn't matter now as the question is closed) I've seen some advertisements about home alarms that notifies me that something is happening in my house. None of them mentioned programmability (with real programming language like e.g C, assembler, whatever). As a programmer I'd like to have a possibility to add some behaviour, that is not part of the alarm itself. This might be: take snapshots of all cameras in a house and send it to some email send email, twitter message, skype message to some predefined account send email to a police (silly, I know) start turning the lights on and off (scary, right?) etc. (would be veeery challenging with assembler, I know; but lets suppose I can use some more high level language) I don't expect that there is a alarm system capable of this stuff, that's why I'm looking for a programmable module. Question: Is it even possible? Is it good idea (my program could crash and cause instability of the system).

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

< Previous Page | 1 2 3 4  | Next Page >