Search Results

Search found 71854 results on 2875 pages for 'build time'.

Page 2/2875 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Teamcity build agent gives 504 gateway timeout

    - by Anthony
    I have a new teamcity build agent machine, which when started up tries to connect to the build server and fails. It never shows up in the connected, disconnected or unauthorised agents tabs of the build server web interface. The logs on the build agent show that it fails to connect with a 504 gateway timeout. This is from teamcity-agent.log [2012-09-04 15:34:59,776] INFO - buildServer.AGENT.registration - Registering on server http://10.0.10.16, AgentDetails{Name='my-local', AgentId=null, BuildId=null, AgentOwnAddress='10.0.1.14', AlternativeAddresses=[10.0.10.32], Port=8080, Version='21424', PluginsVersion='21424-md5-somechecksum', AvailableRunners=[ABunchOfPlugins], AvailableVcs=[SomeRunners], AuthorizationToken='sometoken'} [2012-09-04 15:35:53,606] WARN - buildServer.AGENT.registration - Call http://10.0.10.16/RPC2 buildServer.registerAgent3: org.apache.xmlrpc.XmlRpcClientException: Server returned incorrect status code: 504 Gateway Time-out [2012-09-04 15:35:53,606] WARN - buildServer.AGENT.registration - Connection to TeamCity server is probably lost. Will be trying to restore it. Take a look at logs/teamcity-agent.log for details (unless you're using custom logging). (I have edited some identifying data out of this log excerpt) But I can reach the build server. In fact, tracert shows that it is very nearby. Tracing route to TEAMCITYSERVER [10.0.10.16] over a maximum of 30 hops: 1 <1 ms <1 ms <1 ms 10.0.2.1 2 <1 ms <1 ms <1 ms TEAMCITYSERVER [10.0.10.16] Trace complete. I can see a teamcity login page if I hit http://10.0.10.16 in the browser. The teamcity service is logging in as the same (local administrator) account as I used to log in and test the network. The build agent is a windows 2008 server VM hosted on Ubuntu 12.04 under Oracle VirtualBox. I have disabled firewalls on both the Windows and Ubuntu machines. Other VMS with similar configuration can connect fine and do not report this error. What can possibly be preventing this connection?

    Read the article

  • Part 15: Fail a build based on the exit code of a console application

    In the series the following parts have been published Part 1: Introduction Part 2: Add arguments and variables Part 3: Use more complex arguments Part 4: Create your own activity Part 5: Increase AssemblyVersion Part 6: Use custom type for an argument Part 7: How is the custom assembly found Part 8: Send information to the build log Part 9: Impersonate activities (run under other credentials) Part 10: Include Version Number in the Build Number Part 11: Speed up opening my build process template Part 12: How to debug my custom activities Part 13: Get control over the Build Output Part 14: Execute a PowerShell script Part 15: Fail a build based on the exit code of a console application When you have a Console Application or a batch file that has errors, the exitcode is set to another value then 0. You would expect that the build would see this and report an error. This is not true however. First we setup the scenario. Add a ConsoleApplication project to your solution you are building. In the Main function set the ExitCode to 1     class Program    {        static void Main(string[] args)        {            Console.WriteLine("This is an error in the script.");            Environment.ExitCode = 1;        }    } Checkin the code. You can choose to include this Console Application in the build or you can decide to add the exe to source control Now modify the Build Process Template CustomTemplate.xaml Add an argument ErrornousScript Scroll down beneath the TryCatch activity called “Try Compile, Test, and Associate Changesets and Work Items” Add an Sequence activity to the template In the Sequence, add a ConvertWorkspaceItem and an InvokeProcess activity (see Part 14: Execute a PowerShell script  for more detailed steps) In the FileName property of the InvokeProcess use the ErrornousScript so the ConsoleApplication will be called. Modify the build definition and make sure that the ErrornousScript is executing the exe that is setting the ExitCode to 1. You have now setup a build definition that will execute the errornous Console Application. When you run it, you will see that the build succeeds. This is not what you want! To solve this, you can make use of the Result property on the InvokeProcess activity. So lets change our Build Process Template. Add the new variables (scoped to the sequence where you run the Console Application) called ExitCode (type = Int32) and ErrorMessage Click on the InvokeProcess activity and change the Result property to ExitCode In the Handle Standard Output of the InvokeProcess add a Sequence activity In the Sequence activity, add an Assign primitive. Set the following properties: To = ErrorMessage Value = If(Not String.IsNullOrEmpty(ErrorMessage), Environment.NewLine + ErrorMessage, "") + stdOutput And add the default BuildMessage to the sequence that outputs the stdOutput Add beneath the InvokeProcess activity and If activity with the condition ExitCode <> 0 In the Then section add a Throw activity and set the Exception property to New Exception(ErrorMessage) The complete workflow looks now like When you now check in the Build Process Template and run the build, you get the following result And that is exactly what we want.   You can download the full solution at BuildProcess.zip. It will include the sources of every part and will continue to evolve.

    Read the article

  • How do NTP Servers Manage to Stay so Accurate?

    - by Akemi Iwaya
    Many of us have had the occasional problem with our computers and other devices retaining accurate time settings, but a quick sync with an NTP server makes all well again. But if our own devices can lose accuracy, how do NTP servers manage to stay so accurate? Today’s Question & Answer session comes to us courtesy of SuperUser—a subdivision of Stack Exchange, a community-driven grouping of Q&A web sites. Photo courtesy of LEOL30 (Flickr). The Question SuperUser reader Frank Thornton wants to know how NTP servers are able to remain so accurate: I have noticed that on my servers and other machines, the clocks always drift so that they have to sync up to remain accurate. How do the NTP server clocks keep from drifting and always remain so accurate? How do the NTP servers manage to remain so accurate? The Answer SuperUser contributor Michael Kjorling has the answer for us: NTP servers rely on highly accurate clocks for precision timekeeping. A common time source for central NTP servers are atomic clocks, or GPS receivers (remember that GPS satellites have atomic clocks onboard). These clocks are defined as accurate since they provide a highly exact time reference. There is nothing magical about GPS or atomic clocks that make them tell you exactly what time it is. Because of how atomic clocks work, they are simply very good at, having once been told what time it is, keeping accurate time (since the second is defined in terms of atomic effects). In fact, it is worth noting that GPS time is distinct from the UTC that we are more used to seeing. These atomic clocks are in turn synchronized against International Atomic Time or TAI in order to not only accurately tell the passage of time, but also the time. Once you have an exact time on one system connected to a network like the Internet, it is a matter of protocol engineering enabling transfer of precise times between hosts over an unreliable network. In this regard a Stratum 2 (or farther from the actual time source) NTP server is no different from your desktop system syncing against a set of NTP servers. By the time you have a few accurate times (as obtained from NTP servers or elsewhere) and know the rate of advancement of your local clock (which is easy to determine), you can calculate your local clock’s drift rate relative to the “believed accurate” passage of time. Once locked in, this value can then be used to continuously adjust the local clock to make it report values very close to the accurate passage of time, even if the local real-time clock itself is highly inaccurate. As long as your local clock is not highly erratic, this should allow keeping accurate time for some time even if your upstream time source becomes unavailable for any reason. Some NTP client implementations (probably most ntpd daemon or system service implementations) do this, and others (like ntpd’s companion ntpdate which simply sets the clock once) do not. This is commonly referred to as a drift file because it persistently stores a measure of clock drift, but strictly speaking it does not have to be stored as a specific file on disk. In NTP, Stratum 0 is by definition an accurate time source. Stratum 1 is a system that uses a Stratum 0 time source as its time source (and is thus slightly less accurate than the Stratum 0 time source). Stratum 2 again is slightly less accurate than Stratum 1 because it is syncing its time against the Stratum 1 source and so on. In practice, this loss of accuracy is so small that it is completely negligible in all but the most extreme of cases. Have something to add to the explanation? Sound off in the comments. Want to read more answers from other tech-savvy Stack Exchange users? Check out the full discussion thread here.

    Read the article

  • Enums for Build Flavor and Build Platform in Custom TFS 2010 Build Activities

    - by Ben Hughes
    Are there enums available in the .NET framework that have values for build flavor (Debug, Release) and build platform (Any CPU, x86, x64 etc)? I haven't been able to find anything on MSDN or Google. It seems unnecessarily cumbersome to create my own. For context: I'm creating a custom TFS2010 workflow activity that requires flavor and platform info. Currently these are entered in the build definition as free-from strings. The default TFS build template has a dialog box (accessible in the build definition editor under Process\1.Required\Items to Build\Configurations to Build) that provides drop-down menus with this info pre-populated. I'd like to do something similar.

    Read the article

  • heroku time zone problem, logging local server time

    - by Ole Morten Amundsen
    UPDATE: Ok, I didn't formulate a good Q to be answered. I still struggle with heroku being on -07:00 UTC and I at +02:200 UTC. Q: How do I get the log written in the correct Time.zone ? The 9 hours difference, heroku (us west) - norway, is distracting to work with. I get this in my production.log (using heroku logs): Processing ProductionController#create to xml (for 81.26.51.35 at 2010-04-28 23:00:12) [POST] How do I get it to write 2010-04-29 08:00:12 +02:00 GMT ? Note that I'm running at heroku and cannot set the server time myself, as one could do at your amazon EC2 servers. Below is my previous question, I'll leave it be as it holds some interesting information about time and zones. Why does Time.now yield the server local time when I have set the another time zone in my environment.rb config.time_zone = 'Copenhagen' I've put this in a view <p> Time.zone <%= Time.zone %> </p> <p> Time.now <%= Time.now %> </p> <p> Time.now.utc <%= Time.now.utc %> </p> <p> Time.zone.now <%= Time.zone.now %> </p> <p> Time.zone.today <%= Time.zone.today %> </p> rendering this result on my app at heroku Time.zone (GMT+01:00) Copenhagen Time.now Mon Apr 26 08:28:21 -0700 2010 Time.now.utc Mon Apr 26 15:28:21 UTC 2010 Time.zone.now 2010-04-26 17:28:21 +0200 Time.zone.today 2010-04-26 Time.zone.now yields the correct result. Do I have to switch from Time.now to Time.zone.now, everywhere? Seems cumbersome. I truly don't care what the local time of the server is, it's giving me loads of trouble due to extensive use of Time.now. Am I misunderstanding anything fundamental here?

    Read the article

  • TeamCity build number versus Ant build number task

    - by jonny
    I have a build project that I run from TeamCity, now it takes the build.number from TeamCity. I want to be able to use the buildnumber task (Ant) which in my understanding when used, is supposed to change the value of build number property and increment it for next time. But it seems that I still get the build number from TeamCity. How can I use the build number from <buildnumber file="mybuild.number"/>?

    Read the article

  • JVM system time runs faster than HP UNIX OS system time

    - by winston
    Hello I have the following output from a simple debug jsp: Weblogic Startup Since: Friday, October 19, 2012, 08:36:12 AM Database Current Time: Wednesday, December 12, 2012, 11:43:44 AM Weblogic JVM Current Time: Wednesday, December 12, 2012, 11:45:38 AM Line 1 was a recorded variable during WebLogic webapp startup. Line 2 was output from database query select sysdate from dual; Line 3 was output from java code new Date() I have checked from shell date command that line 2 output conforms with OS time. The output of line 3 was mysterious. I don't know how it comes from Java VM. On another machine with same setting, the same jsp output like this: Weblogic Startup Since: Tuesday, December 11, 2012, 02:29:06 PM Database Current Time: Wednesday, December 12, 2012, 11:51:48 AM Weblogic JVM Current Time: Wednesday, December 12, 2012, 11:51:50 AM Another machine: Weblogic Startup Since: Monday, December 10, 2012, 05:00:34 PM Database Current Time: Wednesday, December 12, 2012, 11:52:03 AM Weblogic JVM Current Time: Wednesday, December 12, 2012, 11:52:07 AM Findings: the pattern shows that the longer Weblogic startup, the larger the discrepancy of OS time with JVM time. Anybody could help on HP JVM? On HP UNIX, NTP was done daily. Anyway here comes the server versions: HP-UX machinex B.11.31 U ia64 2426956366 unlimited-user license java version "1.6.0.04" Java(TM) SE Runtime Environment (build 1.6.0.04-jinteg_28_apr_2009_04_46-b00) Java HotSpot(TM) Server VM (build 11.3-b02-jre1.6.0.04-rc2, mixed mode) WebLogic Server Version: 10.3.2.0 Java properties java.runtime.name=Java(TM) SE Runtime Environment java.runtime.version=1.6.0.04-jinteg_28_apr_2009_04_46-b00 java.vendor=Hewlett-Packard Co. java.vendor.url=http\://www.hp.com/go/Java java.version=1.6.0.04 java.vm.name=Java HotSpot(TM) 64-Bit Server VM java.vm.info=mixed mode java.vm.specification.vendor=Sun Microsystems Inc. java.vm.vendor="Hewlett-Packard Company" sun.arch.data.model=64 sun.cpu.endian=big sun.cpu.isalist=ia64r0 sun.io.unicode.encoding=UnicodeBig sun.java.launcher=SUN_STANDARD sun.jnu.encoding=8859_1 sun.management.compiler=HotSpot 64-Bit Server Compiler sun.os.patch.level=unknown os.name=HP-UX os.version=B.11.31

    Read the article

  • Programmatically use a server as the Build Server for multiple Project Collections

    Important: With this post you create an unsupported scenario by Microsoft. It will break your support for this server with Microsoft. So handle with care. I am the administrator an a TFS environment with a lot of Project Collections. In the supported configuration of Microsoft 2010 you need one Build Controller per Project Collection, and it is not supported to have multiple Build Controllers installed. Jim Lamb created a post how you can modify your system to change this behaviour. But since I have so many Project Collections, I automated this with the API of TFS. When you install a new build server via the UI, you do the following steps Register the build service (with this you hook the windows server into the build server environment) Add a new build controller Add a new build agent So in pseudo code, the code would look like foreach (projectCollection in GetAllProjectCollections) {       CreateNewWindowsService();       RegisterService();       AddNewController();       AddNewAgent(); } The following code fragements show you the most important parts of the method implementations. Attached is the full project. CreateNewWindowsService We create a new windows service with the SC command via the Diagnostics.Process class:             var pi = new ProcessStartInfo("sc.exe")                         {                             Arguments =                                 string.Format(                                     "create \"{0}\" start= auto binpath= \"C:\\Program Files\\Microsoft Team Foundation Server 2010\\Tools\\TfsBuildServiceHost.exe              /NamedInstance:{0}\" DisplayName= \"Visual Studio Team Foundation Build Service Host ({1})\"",                                     serviceHostName, tpcName)                         };            Process.Start(pi);             pi.Arguments = string.Format("failure {0} reset= 86400 actions= restart/60000", serviceHostName);            Process.Start(pi); RegisterService The trick in this method is that we set the NamedInstance static property. This property is Internal, so we need to set it through reflection. To get information on these you need nice Microsoft friends and the .Net reflector .             // Indicate which build service host instance we are using            typeof(BuildServiceHostUtilities).Assembly.GetType("Microsoft.TeamFoundation.Build.Config.BuildServiceHostProcess").InvokeMember("NamedInstance",              System.Reflection.BindingFlags.NonPublic | System.Reflection.BindingFlags.SetProperty | System.Reflection.BindingFlags.Static, null, null, new object[] { serviceName });             // Create the build service host            serviceHost = buildServer.CreateBuildServiceHost(serviceName, endPoint);            serviceHost.Save();             // Register the build service host            BuildServiceHostUtilities.Register(serviceHost, user, password); AddNewController and AddNewAgent Once you have the BuildServerHost, the rest is pretty straightforward. There are methods on the BuildServerHost to modify the controllers and the agents                 controller = serviceHost.CreateBuildController(controllerName);                 agent = controller.ServiceHost.CreateBuildAgent(agentName, buildDirectory, controller);                controller.AddBuildAgent(agent); You have now seen the highlights of the application. If you need it and want to have sample information when you work in this area, download the app TFS2010_RegisterBuildServerToTPCs

    Read the article

  • Apple: Time capsule, 2 questions

    - by Patrick
    1) Can I use time capsule as server ? Can I run operating systems on it ? 2) I'm using time machine with my mac with time capsule. Let's say my mac crashes, and I cannot use it anymore. Can i restore my mac disk on another laptop from time capsule ? In other words, can I have a perfect copy of my mac hard disk on another mac ? thanks

    Read the article

  • Windows Media Player - always show Current Time/Total Time

    - by Siim K
    I'm using Windows Media Player 12 on Windows 7. When I open a video file then it by default only shows the current position (time). If I click on it once then it changes to format Current Time / Total Time Is there any way to make this format permanent (registry hack/some setting I have not noticed)? Right now every time I close WMP and open another file it's back to the default (only current time) setting.

    Read the article

  • Post build events using ROBOCOPY instead of XCOPY

    - by Vizioz Limited
    I don't know about you, but for a long time I have used XCOPY statements in my Visual Studio post build events to copy my Umbraco files from the project folders to the local version of the website associated with the project.For the last few months we have been building a website framework for a client, who has subsequently sold the site to 5 clients, each with a different skin and some variations in their functional requirements.So, we now have a single source solutions, that builds and copies the site files into 5 seperate local websites, which enables us to easily test them all, what we had found was that this process was starting to slow up our build process and was reaching 30-45 seconds on a high spec Quad core machine (and slower on others)Today I asked Colin to create seperate Solution Configurations within Visual Studio so that while we were developing we could target a single site, and when we wanted to test all sites, we could target "ALL" and the Post Build script would then copy the files to all sites.This worked well, and with a couple of other optimisations, our build was now taking about 10 seconds for a single site.Then Colin came across ROBOCOPY and suggested that maybe this would be a suitable alternative to XCOPY, well, I had not heard of it.. (shock horror some of you shout, some I am sure like me, are also wondering what it is!)ROBOCOPY is new in Windows Vista & Windows 7 (you can also download it for XP & Windows 2003) and it has a lot of additional features, the two that were most interesting to us were:/MIR = Mirror a folder tree/XD = Exclude Directories/NP = No Progress (i.e. it does not give you a chart of it's results, which just fills up your Output window!)So, we set about implementing ROBOCOPY, we decided to use the /MIR switch on all folders that we knew were always stored in our project folders:- images- css- masterpages- xsltAnd for other files we just used the straight robocopy functionality.We also decided to exclude all the .SVN directories using the /XD switch and finally we added the /NP switch as mentioned above.The beauty of all of this, is the /MIR functionality, as this means that only files that have changed will be copied across which greatly speeds up the process, especially on the images folders which previously copied across on every build, now, if we add a new image to the project it will be copied across automatically and then never again, unless we change it of course!The build time now for all sites is approximately 4 seconds and for a single site, 2 seconds, I would highly recommend the time to make the same optimisations to your build processes if you have not done so already.

    Read the article

  • Build suggestion for mini itx server [on hold]

    - by Spyros
    I am looking to create a home server and since there does not seem to be a nice ready made one to purchase, i thought of building a mini itx one. I am not familiar with the best hardware/case to pick and therefore i thought i would ask for your experience. I will most probably install a simple linux distro, probably Debian and most probably without a desktop environment as well. Therefore, I am not looking for the best graphics card, though a decent one is preferred for sure. I would say that the most important thing is that the case/hardware play well with each other and the machine has decent specs ( i think something like 8gb RAM and 1TB hdd is most probably my most important things). I understand that this question can be closed as subjective, but it would be a great help for me if some of you guys who have been doing a similar build, can suggest something. I tried to find a stack exchange variant for the question, but it seems that this one more closely relates to the subject. But I will definitely understand it if people close it due to being subjective in nature. If you can maybe move it somewhere or so, please feel free to do so. Thank you for your time :)

    Read the article

  • Team Build MSBuild Task Does Not Update Main Build Log File

    - by NotMyself
    I have an after build event in my main TFSBuild.proj file that uses the MSBuild task to call a deployment task after a successful build. It looks like this: <ItemGroup> <DeploymentTargets Include="..\Sources\Build\SkunkWorks.Build.Deployment.targets"> <Properties></Properties> </DeploymentTargets> </ItemGroup> <Target Name="AfterBuild"> <Message Text="Executing Deployment"/> <MSBuild Projects="@(DeploymentTargets)" Properties="PickUpLocation='@(DropLocation)'" ContinueOnError="false"/> </Target> This works fine and the deployment script is called as you would expect. The problem is that any errors or messages produced by executing the MSBuild are not written to the BuildLog.txt or ErrorsAndWarnings.txt files that are placed in the drop location after a successful build. Is there an easy way to capture this information?

    Read the article

  • Customize Team Build 2010 – Part 16: Specify the relative reference path

    In the series the following parts have been published Part 1: Introduction Part 2: Add arguments and variables Part 3: Use more complex arguments Part 4: Create your own activity Part 5: Increase AssemblyVersion Part 6: Use custom type for an argument Part 7: How is the custom assembly found Part 8: Send information to the build log Part 9: Impersonate activities (run under other credentials) Part 10: Include Version Number in the Build Number Part 11: Speed up opening my build process template Part 12: How to debug my custom activities Part 13: Get control over the Build Output Part 14: Execute a PowerShell script Part 15: Fail a build based on the exit code of a console application Part 16: Specify the relative reference path As I have already blogged about, it is not intuitive how to specify the paths where the build server has to look for references that are stored in Source Control. It is a common practice to store 3rd party libraries in Source Control, so they are available to everyone, everyone uses the same version of the libraries and updating a library can be done centrally. In Team Build 2010 these paths are specified as a parameter for MSBuild. What we will do in this post is building the values for this parameter based on the values in an argument. You are now pretty aware how to customize the build template, so let’s do the modifications in another way. Instead of opening the xaml file in the workflow designer, we open it in the XML editor. You can open it in the XML Editor by either selecting the Open with menu (see the context menu), or by choosing the View code option. To add this functionality we need to: Specify a new argument Add the argument to the metadata Build the absolute paths for the references and add these paths to the MSBuild arguments 1. Specify a new argument Locate at the top of the document the Members (which are the arguments) of the XAML and add the following line <x:Property Name="ReferencePaths" Type="InArgument(s:String[])" /> 2. Add the argument to the metadata Then locate the line <mtbw:ProcessParameterMetadataCollection> and paste the following line <mtbw:ProcessParameterMetadata Category="Misc" Description="The list of reference paths, relative to the root path in the Workspace mapping." DisplayName="Reference paths" ParameterName="ReferencePaths" /> 3. Build the absolute paths for the references and add these paths to the MSBuild arguments Now locate the place where the assignments are done to the variables used in the agent. And add the following lines after the last Assign activity         <Sequence DisplayName="Initialize ReferencePath" sap:VirtualizedContainerService.HintSize="464,428">           <Sequence.Variables>             <Variable x:TypeArguments="x:String" Name="ReferencePathsArgument">               <Variable.Default>                 <Literal x:TypeArguments="x:String" Value="" />               </Variable.Default>             </Variable>           </Sequence.Variables>           <sap:WorkflowViewStateService.ViewState>             <scg:Dictionary x:TypeArguments="x:String, x:Object">               <x:Boolean x:Key="IsExpanded">True</x:Boolean>             </scg:Dictionary>           </sap:WorkflowViewStateService.ViewState>           <ForEach x:TypeArguments="x:String" DisplayName="Iterate through the paths" sap:VirtualizedContainerService.HintSize="287,206" mtbwt:BuildTrackingParticipant.Importance="Low" Values="[ReferencePaths]">             <ActivityAction x:TypeArguments="x:String">               <ActivityAction.Argument>                 <DelegateInArgument x:TypeArguments="x:String" Name="path" />               </ActivityAction.Argument>               <Assign x:TypeArguments="x:String" DisplayName="Build ReferencePath argument" sap:VirtualizedContainerService.HintSize="257,100" mtbwt:BuildTrackingParticipant.Importance="Low"  To="[ReferencePathsArgument]" Value="[If(String.IsNullOrEmpty(ReferencePathsArgument), &quot;&quot;, ReferencePathsArgument + &quot;;&quot;) + IO.Path.Combine(SourcesDirectory, path)]" />             </ActivityAction>           </ForEach>           <Assign DisplayName="Append the reference paths to the MSBuild Arguments" sap:VirtualizedContainerService.HintSize="287,58">             <Assign.To>               <OutArgument x:TypeArguments="x:String">[MSBuildArguments]</OutArgument>             </Assign.To>             <Assign.Value>               <InArgument x:TypeArguments="x:String">[String.Format("{0} /p:ReferencePath=""{1}""", MSBuildArguments, ReferencePathsArgument)]</InArgument>             </Assign.Value>           </Assign>         </Sequence> Now you can use the template to specify the paths relative to SourcesDirectory. You can download the full solution at BuildProcess.zip. It will include the sources of every part and will continue to evolve.

    Read the article

  • How should I log time spent on multiple tasks?

    - by xenoterracide
    In Joel's blog on evidence based scheduling he suggests making estimates based on the smallest unit of work and logging extra work back to the original task. The problem I'm now experiencing is that I'll have create object A with subtask method A which creates object B and test all of the above. I create tasks for each of these that seems to be resulting in ok-ish estimates (need practice), but when I go to log work I find that I worked on 4 tasks at once because I tweak method A and find a bug in the test and refactor object B all while coding it. How should I go about logging this work? should I say I spent, for example, 2 hours on each of the 4 tasks I worked on in the 8 hour day?

    Read the article

  • Help to calculate hours and minutes between two time periods in Excel 2007

    - by Mestika
    Hi, I’m working on a very simple timesheet for my work in Excel 2007 but have ran into trouble about calculate the hours and minutes between two time periods. I have a field: timestart which could be for example: 08:30 Then I have a field timestop which could be for example: 12:30 I can easy calculate the result myself which is 4 hours but how do I create a “total” table all the way down the cell that calculate the hours spend on each entry? I’ve tried to play around with the time settings but it just give me wrong numbers each time. Sincerely Mestika

    Read the article

  • Time tracking tool for monitoring application usage

    - by wizlog
    I want to know how I'm really using my computer, and where the time goes (eg. I have an English paper due, and I intend on getting it done, its 2:30 PM... no wait, its 8:30 PM...). What software can tell me- a. what programs I use, and when b. within programs like Google Chrome or Firefox, which tabs do I spend the most time on. (So I know if I'm spending the time playing a game, or watching a movie on Hulu...)

    Read the article

  • How to change time (Advanced Eastern Time) on Slackware 8.1

    - by r0ca
    Hi all, I have a linux (Slackware) machine and the time/date is like, June 23rd 2003, 10:00am (It's 11 here) and I am not able to set the time to have it correct. I change the timezome to Montreal but the time is still wrong. Is there a way to force it to sync with my domain controler or even another online NTP server? Thanks, David.

    Read the article

  • Amazon EC2 instances changes server time/date on reboots and other time weirdness

    - by puffpio
    I have a windows instance up in EC2. I manually set the timezone to Pacific. 1) For some reason using window's built in time sync doesn't work in the instance...but whatever. I turn off automatic time syncing... but 2) On reboot the time on the server changes! For example, if i reboot it at 4PM on Wednesday, when the server comes back up it will read 12 noon on Thursday! As a result any access to Amazon's other services like SImpleDB fail because the timestamps generated are too far off the current time. Has anyone seen this or figured this out?

    Read the article

  • Time Warp

    - by Jesse
    It’s no secret that daylight savings time can wreak havoc on systems that rely heavily on dates. The system I work on is centered around recording dates and times, so naturally my co-workers and I have seen our fair share of date-related bugs. From time to time, however, we come across something that we haven’t seen before. A few weeks ago the following error message started showing up in our logs: “The supplied DateTime represents an invalid time. For example, when the clock is adjusted forward, any time in the period that is skipped is invalid.” This seemed very cryptic, especially since it was coming from areas of our application that are typically only concerned with capturing date-only (no explicit time component) from the user, like reports that take a “start date” and “end date” parameter. For these types of parameters we just leave off the time component when capturing the date values, so midnight is used as a “placeholder” time. How is midnight an “invalid time”? Globalization Is Hard Over the last couple of years our software has been rolled out to users in several countries outside of the United States, including Brazil. Brazil begins and ends daylight savings time at midnight on pre-determined days of the year. On October 16, 2011 at midnight many areas in Brazil began observing daylight savings time at which time their clocks were set forward one hour. This means that at the instant it became midnight on October 16, it actually became 1:00 AM, so any time between 12:00 AM and 12:59:59 AM never actually happened. Because we store all date values in the database in UTC, always adjust any “local” dates provided by a user to UTC before using them as filters in a query. The error we saw was thrown by .NET when trying to convert the Brazilian local time of 2011-10-16 12:00 AM to UTC since that local time never actually existed. We hadn’t experienced this same issue with any of our US customers because the daylight savings time changes in the US occur at 2:00 AM which doesn’t conflict with our “placeholder” time of midnight. Detecting Invalid Times In .NET you might use code similar to the following for converting a local time to UTC: var localDate = new DateTime(2011, 10, 16); //2011-10-16 @ midnight const string timeZoneId = "E. South America Standard Time"; //Windows system timezone Id for "Brasilia" timezone. var localTimeZone = TimeZoneInfo.FindSystemTimeZoneById(timeZoneId); var convertedDate = TimeZoneInfo.ConvertTimeToUtc(localDate, localTimeZone); The code above throws the “invalid time” exception referenced above. We could try to detect whether or not the local time is invalid with something like this: var localDate = new DateTime(2011, 10, 16); //2011-10-16 @ midnight const string timeZoneId = "E. South America Standard Time"; //Windows system timezone Id for "Brasilia" timezone. var localTimeZone = TimeZoneInfo.FindSystemTimeZoneById(timeZoneId); if (localTimeZone.IsInvalidTime(localDate)) localDate = localDate.AddHours(1); var convertedDate = TimeZoneInfo.ConvertTimeToUtc(localDate, localTimeZone); This code works in this particular scenario, but it hardly seems robust. It also does nothing to address the issue that can arise when dealing with the ambiguous times that fall around the end of daylight savings. When we roll the clocks back an hour they record the same hour on the same day twice in a row. To continue on with our Brazil example, on February 19, 2012 at 12:00 AM, it will immediately become February 18, 2012 at 11:00 PM all over again. In this scenario, how should we interpret February 18, 2011 11:30 PM? Enter Noda Time I heard about Noda Time, the .NET port of the Java library Joda Time, a little while back and filed it away in the back of my mind under the “sounds-like-it-might-be-useful-someday” category.  Let’s see how we might deal with the issue of invalid and ambiguous local times using Noda Time (note that as of this writing the samples below will only work using the latest code available from the Noda Time repo on Google Code. The NuGet package version 0.1.0 published 2011-08-19 will incorrectly report unambiguous times as being ambiguous) : var localDateTime = new LocalDateTime(2011, 10, 16, 0, 0); const string timeZoneId = "Brazil/East"; var timezone = DateTimeZone.ForId(timeZoneId); var localDateTimeMaping = timezone.MapLocalDateTime(localDateTime); ZonedDateTime unambiguousLocalDateTime; switch (localDateTimeMaping.Type) { case ZoneLocalMapping.ResultType.Unambiguous: unambiguousLocalDateTime = localDateTimeMaping.UnambiguousMapping; break; case ZoneLocalMapping.ResultType.Ambiguous: unambiguousLocalDateTime = localDateTimeMaping.EarlierMapping; break; case ZoneLocalMapping.ResultType.Skipped: unambiguousLocalDateTime = new ZonedDateTime( localDateTimeMaping.ZoneIntervalAfterTransition.Start, timezone); break; default: throw new InvalidOperationException(string.Format("Unexpected mapping result type: {0}", localDateTimeMaping.Type)); } var convertedDateTime = unambiguousLocalDateTime.ToInstant().ToDateTimeUtc(); Let’s break this sample down: I’m using the Noda Time ‘LocalDateTime’ object to represent the local date and time. I’ve provided the year, month, day, hour, and minute (zeros for the hour and minute here represent midnight). You can think of a ‘LocalDateTime’ as an “invalidated” date and time; there is no information available about the time zone that this date and time belong to, so Noda Time can’t make any guarantees about its ambiguity. The ‘timeZoneId’ in this sample is different than the ones above. In order to use the .NET TimeZoneInfo class we need to provide Windows time zone ids. Noda Time expects an Olson (tz / zoneinfo) time zone identifier and does not currently offer any means of mapping the Windows time zones to their Olson counterparts, though project owner Jon Skeet has said that some sort of mapping will be publicly accessible at some point in the future. I’m making use of the Noda Time ‘DateTimeZone.MapLocalDateTime’ method to disambiguate the original local date time value. This method returns an instance of the Noda Time object ‘ZoneLocalMapping’ containing information about the provided local date time maps to the provided time zone.  The disambiguated local date and time value will be stored in the ‘unambiguousLocalDateTime’ variable as an instance of the Noda Time ‘ZonedDateTime’ object. An instance of this object represents a completely unambiguous point in time and is comprised of a local date and time, a time zone, and an offset from UTC. Instances of ZonedDateTime can only be created from within the Noda Time assembly (the constructor is ‘internal’) to ensure to callers that each instance represents an unambiguous point in time. The value of the ‘unambiguousLocalDateTime’ might vary depending upon the ‘ResultType’ returned by the ‘MapLocalDateTime’ method. There are three possible outcomes: If the provided local date time is unambiguous in the provided time zone I can immediately set the ‘unambiguousLocalDateTime’ variable from the ‘Unambiguous Mapping’ property of the mapping returned by the ‘MapLocalDateTime’ method. If the provided local date time is ambiguous in the provided time zone (i.e. it falls in an hour that was repeated when moving clocks backward from Daylight Savings to Standard Time), I can use the ‘EarlierMapping’ property to get the earlier of the two possible local dates to define the unambiguous local date and time that I need. I could have also opted to use the ‘LaterMapping’ property in this case, or even returned an error and asked the user to specify the proper choice. The important thing to note here is that as the programmer I’ve been forced to deal with what appears to be an ambiguous date and time. If the provided local date time represents a skipped time (i.e. it falls in an hour that was skipped when moving clocks forward from Standard Time to Daylight Savings Time),  I have access to the time intervals that fell immediately before and immediately after the point in time that caused my date to be skipped. In this case I have opted to disambiguate my local date and time by moving it forward to the beginning of the interval immediately following the skipped period. Again, I could opt to use the end of the interval immediately preceding the skipped period, or raise an error depending on the needs of the application. The point of this code is to convert a local date and time to a UTC date and time for use in a SQL Server database, so the final ‘convertedDate’  variable (typed as a plain old .NET DateTime) has its value set from a Noda Time ‘Instant’. An 'Instant’ represents a number of ticks since 1970-01-01 at midnight (Unix epoch) and can easily be converted to a .NET DateTime in the UTC time zone using the ‘ToDateTimeUtc()’ method. This sample is admittedly contrived and could certainly use some refactoring, but I think it captures the general approach needed to take a local date and time and convert it to UTC with Noda Time. At first glance it might seem that Noda Time makes this “simple” code more complicated and verbose because it forces you to explicitly deal with the local date disambiguation, but I feel that the length and complexity of the Noda Time sample is proportionate to the complexity of the problem. Using TimeZoneInfo leaves you susceptible to overlooking ambiguous and skipped times that could result in run-time errors or (even worse) run-time data corruption in the form of a local date and time being adjusted to UTC incorrectly. I should point out that this research is my first look at Noda Time and I know that I’ve only scratched the surface of its full capabilities. I also think it’s safe to say that it’s still beta software for the time being so I’m not rushing out to use it production systems just yet, but I will definitely be tinkering with it more and keeping an eye on it as it progresses.

    Read the article

  • MS Build Script accepting a list or collection of project names to build and deploy

    - by Darryn Parker
    I want to create a MS Build script (executed by way of TFS Build Server) that will accept a list of project names that need to be built, unit tested and deployed. The reason is that I want one script to serve many 'like' structured solutions. All the solutions are SOA in nature and share the same framework, project structure and deployment requirements. I've done this in Nant and acheived great success out of having one build file serving 4 solutions - it just accepted a list of web project names to compile and deploy to our test/uat environments. What is the syntax to cycle through a collection of project names suppled as params via MS Build?

    Read the article

  • WDK build-process hooks: need incremental build with auto-versioning

    - by Mystagogue
    I've previously gotten incremental builds with auto-versioning working in a team build setting for user-mode code, but now I'm dealing with the builds of WDK device drivers. It's a whole new ball-game. I need to know what extension point, or hook, is available in the WDK build that occurs after the driver has been selected to be incrementally built, but before it actually starts building the object files. More specifically, I have a .rc file that contains the version of the device driver. I need to update the version in that file ONLY IF the driver is going to be built anyway. If I bump the value in the .rc file prematurely, it will cause the incremental build to kick-off (that is bad). If I wait too long, then the incremental build won't see that I've changed the .rc file. Either way, I do need the WDK to realize that the new version I've placed into the .rc file needs to be built into a new .res file and linked. How do I do this? What suggested extension points should I play with? Is there a link-tutorial on the WDK build process that is particularly revealing regarding this topic?

    Read the article

  • How to prevent parallel builds per build configuration across multiple Build Agents

    - by vanslly
    I have many build configurations in TeamCity, each servicing a large project. In the past if a build is kicked off the Build Agent could be busy for up to 20min! In order to improve throughput I installed a second Build Agent on the same machine such that if a build run is kicked off by say Build Agent 1 and it is busy for 20min and someone from another project makes a change then Build Agent 2 can do the build for the other project without needing to wait on the current build run to finish. All was well until two successive check-ins resulted in both Build Agents running a build for a single build configuration in parallel. Since some resources are shared, IIS directories & databases, I don't want a single build configuration to run on both Build Agents in parallel. How can I ensure a build isn't triggered if a build is currently running for that build configuration on a different build agent? One way seems to involve environmental variables and ensuring a 50/50 split by Build Agent in terms of build configuration compatibility, but that seems a little clunky.

    Read the article

  • Why can't I build Deluge?

    - by hugemeow
    Deluge is a BitTorrent Client. I am trying to build it from source, since I don't have privilege to install it as root. I am using python setup.py build. But, it failed following message, why? copying deluge/ui/web/themes/images/gray/slider/slider-v-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/slider copying deluge/ui/web/themes/images/gray/slider/slider-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/slider copying deluge/ui/web/themes/images/gray/panel/top-bottom.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/panel copying deluge/ui/web/themes/images/gray/tabs/tab-strip-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/gray/tabs copying deluge/ui/web/themes/images/yourtheme/window/right-corners.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window copying deluge/ui/web/themes/images/yourtheme/window/left-corners.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window copying deluge/ui/web/themes/images/yourtheme/window/left-right.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window copying deluge/ui/web/themes/images/yourtheme/window/top-bottom.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/window creating build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-v-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-thumb.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/slider/slider-v-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/slider copying deluge/ui/web/themes/images/yourtheme/panel/top-bottom.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/panel copying deluge/ui/web/themes/images/yourtheme/grid/hmenu-lock.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/grid copying deluge/ui/web/themes/images/yourtheme/grid/hmenu-unlock.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/grid copying deluge/ui/web/themes/images/yourtheme/tabs/tab-strip-bg.png -> build/lib.linux-x86_64-2.4/deluge/ui/web/themes/images/yourtheme/tabs running build_ext building 'libtorrent' extension gcc -pthread -shared -L/usr/lib64 -L/opt/local/lib -lboost_filesystem -lboost_date_time -lboost_iostreams -lboost_python -lboost_thread -lpthread -lssl -lz -o build/lib.linux-x86_64-2.4/deluge/libtorrent.so /usr/bin/ld: cannot find -lboost_filesystem collect2: ld returned 1 exit status error: command 'gcc' failed with exit status 1 [mirror@innov deluge-1.3.5]$ echo $? 1 Edit 1: gcc version and os information $(which gcc) --version gcc (GCC) 4.1.2 20080704 (Red Hat 4.1.2-52) Copyright (C) 2006 Free Software Foundation, Inc. This is free software; see the source for copying conditions. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. cat /etc/issue CentOS release 5.7 (Final) Kernel \r on an \m Edit 2: boost is referenced by setup.py in deluge 114 if OS == "linux": 115 if os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 116 'libboost_filesystem-mt.so')): 117 boost_filesystem = "boost_filesystem-mt" 118 elif os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 119 'libboost_filesystem.so')): 120 boost_filesystem = "boost_filesystem" 121 if os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 122 'libboost_date_time-mt.so')): 123 boost_date_time = "boost_date_time-mt" 124 elif os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 125 'libboost_date_time.so')): 126 boost_date_time = "boost_date_time" 127 if os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 128 'libboost_thread-mt.so')): 129 boost_thread = "boost_thread-mt" 130 elif os.path.exists(os.path.join(sysconfig.get_config_vars()['LIBDIR'], \ 131 'libboost_thread.so')): 132 boost_thread = "boost_thread" 133 134 if 'boost_filesystem' not in vars(): 135 boost_filesystem = "boost_filesystem-mt" 136 if 'boost_date_time' not in vars(): 137 boost_date_time = "boost_date_time-mt" 138 if 'boost_thread' not in vars(): 139 boost_thread = "boost_thread-mt" 140 141 elif OS == "freebsd": 142 boost_filesystem = "boost_filesystem" 143 boost_date_time = "boost_date_time" 144 boost_thread = "boost_thread" 145 else: 146 boost_filesystem = "boost_filesystem-mt" 147 boost_date_time = "boost_date_time-mt" 148 boost_thread = "boost_thread-mt" 149 150 librariestype = [boost_filesystem, boost_date_time, 151 boost_thread, 'z', 'pthread', 'ssl', 'crypto']

    Read the article

  • Internet Time tab has disappeared from the Date and Time applet of the Control Panel

    - by Robert Thornton
    Previously, there was an Internet Time tab on the Date and Time applet of the Control Panel, wherein one could force a query of an internet time server and also type in a different server from the ones supplied. However, this tab has now disappeared, and I need to have it back. I should mention that this machine has never been part of a domain, since it seems that machines that are such do not have such a tab. I should be obliged to anyone who can help me restore the missing tab. Windows 7 Home Premium Service Pack 1

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >