Search Results

Search found 1132 results on 46 pages for 'josh blade'.

Page 2/46 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Webcast: Best Practices for Speeding Virtual Infrastructure Deployment with Oracle VM

    - by Honglin Su
    We announced Oracle VM Blade Cluster Reference Configuration last month, see the blog. The new Oracle VM blade cluster reference configuration can help reduce the time to deploy virtual infrastructure by up to 98 percent when compared to multi-vendor configurations. Customers and partners have shown lots of interests. Join Oracle's experts to learn the best practices for speeding virtual infrastructure deployment with Oracle VM, register the webcast (1/25/2011) here.   Virtualization has already been widely accepted as a means to increase IT flexibility and help IT services align better with changing business needs. The flexibility of a virtualized IT infrastructure enables new applications to be rapidly deployed, capacity to be easily scaled, and IT resources to be quickly redirected. The net result is that IT can bring greater value to the business, making virtualization an obvious win from a business perspective. However, building a virtualized infrastructure typically requires assembling and integrating multiple components (e.g. servers, storage, network, virtualization, and operating systems). This infrastructure must be deployed and tested before applications can even be installed. It can take weeks or months to plan, architect, configure, troubleshoot, and deploy a virtualized infrastructure. The process is not only time-consuming, but also error-prone, making it hard to achieve a timely and profitable return on investment.  Oracle is the only vendor that can offer a fully integrated virtualization infrastructure with all of the necessary hardware and software components. The Oracle VM blade cluster reference configuration is a single-vendor solution that addresses every layer of the virtualization stack with Oracle hardware and software components, see the figure below. It enables quick and easy deployment of the virtualized infrastructure using components that have been tested together and are all supported together by Oracle. To learn more about Oracle's virtualization offerings, visit http://oracle.com/virtualization.

    Read the article

  • Oracle RAC interconnect in a Dell M1000e Blade Enclosure

    - by Antitribu
    We are looking at a Dell M1000e enclosure and appropriate Blades with 4 NICs each. We are planning on running Linux/Oracle 11g RAC on two blades, storage will be handled on an iSCSI SAN for which two NICs (via passthrough) will be connected leaving us with two NICs (via blade centre switches). We would like to have an interconnect (obviously) , an external IP and an internal IP. Would best practice be to: bond the remaining two interfaces and VLAN as appropriate to provide three virtual interfaces? run the interconnect on one interface and VLAN the external/internal interfaces? purchase a blade with more NICs as the above is a terrible idea? Another option? Please feel free to point out the blindingly obvious or to relevant documentation on support.oracle. I am specifically interested in supported configurations and best practices. Thanks!

    Read the article

  • Is Hacom Mars II Dual Blade good ?

    - by Joachim H. Skeie
    I am considering getting a Hacom Mars II Dual Blade for use as a firewall in a data-center for one of my colocated solutions. As the 1U enclosure have two identical firewalls, I am intending to use one of the firewalls as the external firewall using packet-filtering and load balancer (balancing load for my front-end nodes), while using the second as the internal firewall (as an application gateway). But I have no experience with Hacom, or pfSense firewalls. They do look really good on paper, but how are they in practice ?

    Read the article

  • Josh Smith's MVVM Demo App: Add commands to MainWindowViewModel's command list

    - by MAD9
    I have a question concerning Josh Smith's famous demo app on MVVM. I try building a "real" application around it to learn WPF. He creates this CommandsList in the MainWindowViewModel containing 2 Commands (create new and view all customers). This list is readonly (why? any particular reason?). I thougt it would be nice to add and remove some commands, depending on the workspace that is currently selected. Like edit or delete a customer when it has the focus and so on. How would I accomplish this?! Can I just make it a normal list and add commands? Or bind the Commands-View to a commands list of the selected workspace instead of the MainWindow? How? Any other ways? Please share your ideas! Thank you very much!

    Read the article

  • IBM HS23 Blade Server (7875) onboard NIC driver for linux

    - by Igor Spivak
    I work with IBM HS23 Blade Server (7875). It's onboard NIC adapter is: Emulex OCl11104-F-X Virtual Fabric Adapter 2-port 10GB and 2-port 1GB LOM . I'm tryed to the following Linux OS with the server: 2.6.32-22-generic-pae #36-Ubuntu SMP. and discovered my OS has not proper Network drive installed (for the NIC adapter described above). After investigation I made, I discovered that the driver I need is "be2net" placed in "net" directory of the linux under the folder "be2net". I managed to download this driver with the latest package for my kernel. Driver info ("modinfo be2net" result) is as follows: --------------------------------------------------------------------------------------- filename: /lib/modules/2.6.32-22-generic-pae/kernel/drivers/net/benet/be2net.ko license: GPL author: ServerEngines Corporation description: ServerEngines BladeEngine2 10Gbps NICDriver 2.101.205 version: 2.101.205 srcversion: 199ADD251CB874C3727CC47 alias: pci:v000019A2d00000710sv*sd*bc*sc*i* alias: pci:v000019A2d00000701sv*sd*bc*sc*i* alias: pci:v000019A2d00000700sv*sd*bc*sc*i* alias: pci:v000019A2d00000221sv*sd*bc*sc*i* alias: pci:v000019A2d00000211sv*sd*bc*sc*i* depends: vermagic: 2.6.32-22-generic-pae SMP mod_unload modversions 586TSC parm: rx_frag_size:Size of a fragment that holds rcvd data. (uint) --------------------------------------------------------------------------------------- After starting linux, I get the following error: be2net 0000:16:00.x: Emulex OneConnect 10Gbps NIC (be3) initilization failed. I checked the same server with another Linux version (Red-Had 5.5.1.0) and the NICs worked properly, so seems there is no problem in HW. Also, on IBM or Emulex offical sites I managed to find drivers only for Red-Had and SUSE versions.

    Read the article

  • New Reference Configuration: Accelerate Deployment of Virtual Infrastructure

    - by monica.kumar
    Today, Oracle announced the availability of Oracle VM blade cluster reference configuration based on Sun servers, storage and Oracle VM software. Assembling and integrating software and hardware systems from different vendors can be a huge barrier to deploying virtualized infrastructures as it is often a complicated, time-consuming, risky and expensive process. Using this tested configuration can help reduce the time to configure and deploy a virtual infrastructure by up to 98% as compared to putting together multi-vendor configurations. Once ready, the infrastructure can be used to easily deploy enterprise applications in a matter of minutes to hours as opposed to days/weeks, by using Oracle VM Templates. Find out more: Press Release Business whitepaper Technical whitepaper

    Read the article

  • Passing a parameter using RelayCommand defined in the ViewModel (from Josh Smith example)

    - by eesh
    I would like to pass a parameter defined in the XAML (View) of my application to the ViewModel class by using the RelayCommand. I followed Josh Smith's excellent article on MVVM and have implemented the following. XAML Code <Button Command="{Binding Path=ACommandWithAParameter}" CommandParameter="Orange" HorizontalAlignment="Left" Style="{DynamicResource SimpleButton}" VerticalAlignment="Top" Content="Button"/> ViewModel Code public RelayCommand _aCommandWithAParameter; /// <summary> /// Returns a command with a parameter /// </summary> public RelayCommand ACommandWithAParameter { get { if (_aCommandWithAParameter == null) { _aCommandWithAParameter = new RelayCommand( param => this.CommandWithAParameter("Apple") ); } return _aCommandWithAParameter; } } public void CommandWithAParameter(String aParameter) { String theParameter = aParameter; } #endregion I set a breakpoint in the CommandWithAParameter method and observed that aParameter was set to "Apple", and not "Orange". This seems obvious as the method CommandWithAParameter is being called with the literal String "Apple". However, looking up the execution stack, I can see that "Orange", the CommandParameter I set in the XAML is the parameter value for RelayCommand implemenation of the ICommand Execute interface method. That is the value of parameter in the method below of the execution stack is "Orange", public void Execute(object parameter) { _execute(parameter); } What I am trying to figure out is how to create the RelayCommand ACommandWithAParameter property such that it can call the CommandWithAParameter method with the CommandParameter "Orange" defined in the XAML. Is there a way to do this? Why do I want to do this? Part of "On The Fly Localization" In my particular implementation I want to create a SetLanguage RelayCommand that can be bound to multiple buttons. I would like to pass the two character language identifier ("en", "es", "ja", etc) as the CommandParameter and have that be defined for each "set language" button defined in the XAML. I want to avoid having to create a SetLanguageToXXX command for each language supporting and hard coding the two character language identifier into each RelayCommand in the ViewModel.

    Read the article

  • problem with tabbed interface as mentioned in the article of josh smith

    - by Egi
    hello guys, i ve got a problem with my programm. here is the link: http://dl.dropbox.com/u/2734432/TabbedInterface.7z once u have opened both tabs, u ll start loosing the references to other collections of the current item in the view. that is because these ids are nullable and once you switch over to the other tab they ll become null. my question is why and how can i corrent that behavoir? if you change the int? to int there are no more problem, but i need them to be nullable!

    Read the article

  • Restart Fibre channel controller after blade bootup IBM HS bladecentre

    - by Spence
    I have a remote system that needs to resume on startup. If the system is simply powered on then the blades boot before the SAN is online and then the only thing you can do is restart the systems. Is it possible to restart the fibre channel controller? That way I could have a system restart the controller after boot, connect to the SAN and then restart all servers requiring SAN information? Please note that I'm not a sys admin, just shooting for ideas to get a clean startup to work, apologies if my terminology is wrong.

    Read the article

  • IBM BladeServer Chassis compatibility

    - by Matt
    Hi, I'm looking at buying a 3 year old blade server. My question is, if I buy it and want to insert a current model blade, will it fit? Also, if the chassis goes "POP" and I need to replace it, will the current model chassis fit 3 year old blades? What about Power supply replacements? The chassis I'm looking at is this: IBM FRU / PN: M8677-3XM with DVD reader The blades are all IBM HS20's. We've had a good run with IBM hardware and although there is some nice ex-lease HP hardware available, my understanding is that backwards comparability is not so well maintained. Is this true?

    Read the article

  • Bound external Cisco CIGESM ports to a specific BladeServer

    - by Vinícius Ferrão
    We have an IBM BladeCenter with 14 blade servers and one external Cisco CIGESM for Ethernet connectivity. Since this hardware is a little old, we will use it for other services, and we want to run a pfSense instance on one of the blades. It's just an Firewall Appliance, but it needs two network interfaces: one for the WAN and the other one for LAN access. Our architecture works on top of static routes, we don't use NAT, so we got the WAN IP in one interface routing to the another one. The main problem is how to plug the WAN cable in one of the four external ports and make it exclusive to the blade server containing the firewall. And we also need an exit port that goes through a 3COM 4200G switch that makes the internal routing and VLAN separation. Thanks in advance

    Read the article

  • Installing esx 3.5 on hpblade 460c G7

    - by stillStudent
    I was trying to install ESX 3.5 on hp blade 460c but it fails with error no 'network adapter is detected'. Anybody has work around for this. I also tried to install ESX 4.1, it also had the same problem but in case of 4.1 there is support to add your custom driver while installing. So I added NIC drivers and installation completed successfully. ESX 3.5 installtion does not support adding custom drivers while installing. I can't use ESX 4.1 because it does not support 'license server' configuration and only asks for license file(key). I do not have license keys, I only have vmware license server. That is the reason I have to be with ESX 3.5.

    Read the article

  • Planning to buy a server with at least 48GB Ram, are the blades way to go?

    - by varchar1
    We're planning to host our website for the first time for ourselves. We have currently have a linode of 8 gigs and the memory is going up to 90% most of the time. So I want to move my website to my own server with huge RAM. So this will be first time to manage any physical hardware of a server. So I came across IBM's BladeCenter, found them interesting. So can I just buy the blade and run it? Or do I have to buy the chassis for sure? Also, do I need to buy an UPS? So how hard is it to setup? How about the hard drives? Can I setup them easily? Please advice.

    Read the article

  • Why do some software not get load balanced even when there are multiple cores?

    - by Nav
    While VTune Analyzer was running on a blade server with 8 cores, I observed the cpu useage percentage using mpstat -P ALL 1. mpstat showed me that VTune was taking up 100% of a single core, while all other cores were idle. Why does that happen? Shouldn't the OS (RHEL Server 5.2) automatically distribute load across cores? The same happened when I tried running MATLAB (even after enabling multithreading support in the MATLAB settings). p.s: I'm a developer. Not a sys admin. So felt it better to ask here rather than at serverfault.

    Read the article

  • Remote RIB iLO on Proliant via RIBCL

    - by Wudang
    I'm trying to automate a process for our Ops. The process requires that some windows servers running on blades are shut down, left down for a few hours, the restarted when some other processes complete. This is done by an op logging on to each blade's iLO web interface to stop and start. I've been trying to automate this with HP's cpqlocfg program with partial success. I can issue the GET_POWER, GET_USER_INFO, etc commands but SET_HOST_POWER fails in a specific way. Using the cpqlocfg GET_EVENTLOG command I can see the events XML login and the power comand being issued from the iLO interface but then nothing happens. Some hints from googling suggest ACPI isn't configured properly but I can't find any hits on how to verify this. Am I even using the right command? There's also a few other options like PRESS_PWR_BUTTON etc. Problem is I have nowhere to test this, all I can do at the moment is give a script to ops and ask them to try it as 4am on a Sunday when they try the proc. The shutdown is trivial as I can use the windows "shutdown" command, it's the power on that I need help on. Anyone done this? I'd tag this "rib ribcl ilo" but lack the rep points, sorry.

    Read the article

  • Multiple servers vs 1 big server performace

    - by pistacchio
    Hi to all! My team of developers has suggested a server structure for an upcoming project we are developing. Our structure is "logical", meaning that the various logical components of the application (it is a distributed one) relies on different servers. Some components are more critical than others and will be subjected to more load. Our proposal was to have 1 server per component but the hardware guys suggested to replace the various machines with a single, bigger one with virtual servers. They're gonna use Blade Servers. Now, I'm not an expert at all, but my question to the guys was: so if we need, for example, 3 2GHz CPU / 2GB RAM machines and you give me 1 machine with 3 2GHz CPUs and 6 GB of RAM it is the same? They told me it is. Is this accurate? What are the advantages or disadvantages of both the solutions? What are the generally accepted best practices? Could you point out some URL reference dealing with the problem? Thank you in advance! EDIT: Some more info. The (internet / intranet) application is already layered. We have some servers on the DMZ that will expose pages to the internet and the databases are on their own machines. What we want to split (and they want to join) are some webservers that mainly expose webservices. One is a DAL that communicates with the database layer, one is our Single Sign On / User Profile application that gets called once per page and one is a clone of what seen on the Internet to be used on our lan.

    Read the article

  • New Netra SPARC T3 Servers

    - by Ferhat Hatay
    Today at the Mobile World Congress 2011, Oracle announced two new carrier-grade NEBS Level 3- certified servers: Oracle’s Netra SPARC T3-1 rackmount server and Oracle’s Netra SPARC T3-1BA ATCA blade server bringing the performance, scalability and power efficiency of the newest SPARC T3 processor to the communications market.    The Netra SPARC T3-1 server enclosure has a compact 20inch-deep carrier-grade rack-optimized design The new Netra SPARC T3 servers further expand Oracle’s complete portfolio for the communications industry, which includes carrier-grade servers, storage and application software to run operations support systems and service delivery platforms with easy migration capabilities and unmatched investment protection via the binary compatibility guarantee of the Oracle Solaris operating system. With advanced reliability, networking and security features built-in to Oracle Solaris – the most widely deployed carrier-grade OS – the systems announced today are uniquely suited for mission-critical core network infrastructure and service delivery. The world’s first carrier-grade system using the 16-core, 128-thread SPARC T3 processor, the Netra SPARC T3-1 server supports 2x the I/O bandwidth, 2x the memory and is 35 percent faster than the previous generation. With integrated on-chip 10 Gigabit Ethernet, on-chip cryptographic acceleration, and built-in, no-cost Oracle VM Server for SPARC and Oracle Solaris Containers for virtualization, the Netra SPARC T3-1 server is an ideal platform for consolidation, offering 128 virtual systems in a single server. As the next generation Netra SPARC ATCA blade, Netra SPARC T3-1BA ATCA blade server brings the PICMG 3.0 compatibility, NEBS Level 3 Certification, ETSI compliance and the Netra business practices to the customer solution. The Netra SPARC T3-1BA ATCA blade server can be mixed in the Sun Netra CT900 blade chassis with other ATCA UltraSPARC and x86 blades.     The Netra SPARC T3-1BA ATCA blade server   The Netra SPARC T3-1BA ATCA blade server delivers industry-leading scalability, density and cost efficiency with up to 36 SPARC T3 processors (3456 processing threads) in a single rack – a 50 percent increase over the previous generation. The Netra SPARC T3-1BA blade server also offers high-bandwidth and high-capacity I/O, with greater memory capacity to tackle the increasing business demands of the communications industry. For service providers faced with the rapid growth of broadband networks and the dramatic surge in global smartphone adoption, the new Netra SPARC T3 systems deliver continuous availability with massive scalability, tested and certified to run in the harshest conditions. More information Oracle’s Sun Netra Servers Scaling Throughput and Managing TCO with Oracle’s Netra SPARC T3-1 Servers Enabling End-to-End 10 Gigabit Ethernet in Oracle's Sun Netra ATCA Product Family Data Sheet: Netra SPARC T3-1BA ATCA Blade Server Data Sheet: Netra SPARC T3-1 Server Oracle Solaris: The Carrier Grade Operating System

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >