Search Results

Search found 71 results on 3 pages for 'miki watts'.

Page 2/3 | < Previous Page | 1 2 3  | Next Page >

  • Implementing Multitasking on an iPhone/iOS4 Web App

    - by Peter Watts
    I am looking to build a web app that implements background audio and fast app switching. These features work out of the box, when run as regular Safari web pages, but as soon as you add the web-app-capable tag, and try to run in full screen mode, this functionality breaks. I did some testing and even the most basic web app will reload every time when you switch back to it. And seeing as it's a web app, we can't exactly implement the multitasking API. Has anyone found a work around? This isn't a deal-breaker, as you can just avoid full screen mode, but then you also lose the ability to use your own icon in the app switch tray. Perhaps this explains a lack of full screen mode in YouTube's new web app....

    Read the article

  • How to disable WM6.5.3 gestures?

    - by Duncan Watts
    I am working on a .NET 2.0 application targetting the WM5 SDK, what is the correct way to disable the gesture functionality when running on a WM6.5.3 device that only affects the forms I am using? This is causing an issue when I have a signature capture control inside a tab control - when the signature is entered it's quite common for the tab control to switch tabs as WM6.5.3 picks it up as a gesture. I don't want to disable the gesture functionality device wide, nor can I upgrade the application to target the WM6.5.3 SDK as it still needs to work on older devices. Cheers

    Read the article

  • WiX - How do I prevent ComPlusAssembly being unregistered during uninstall?

    - by Duncan Watts
    As part of my Installer, I am adding files to an existing COM+ package. I have defined a ComPlusApplication underneath my Product element, which has the name set to a property - I then have a custom action which looks up that property - all good so far. When the installer adds the files, within the same component I have added a ComPlusAssembly which adds the assembly to the ComPlusApplication I defined above - this is also working correctly. When uninstalled however, I am receiving an error related to being unable to find the COM+ application, this is because I am not running my custom action to look up the name of the COM+ package. Basically I do not want to remove my files or unregister the component package as part of the uninstallation process - How do I achieve this? I am using WiX 3.0 with VS2008. Thanks

    Read the article

  • Jquery.Validate plugin + realPerson plugin

    - by Dave Watts
    I can't figure out how to make it so the form wont fire unless the realPerson captcha is "valid". I can see that when the user types in the correct/valid letters and clicks submit it adds a class of "valid" to the input. So Ive been trying to figure out how to get the jquery.validate plugin to only fire when the class "valid" is present. <script type="text/javascript"> $(document).ready(function(){ $('#defaultReal').realperson(); $('#contact_form2').validate({ submitHandler: function(form) { var str = $("form").serialize(); $.ajax({ type: "POST", url: "contactpage.php", data: str, success: function(){ $('#contact_form2').html("<div id='message'></div>"); $('#message').html("<h2>Contact Form Submitted!</h2>") .append("<p>We will be in touch soon.</p>") .hide() .fadeIn(1500, function() { $('#message').append("<img id='checkmark' src='images/check.png' />"); }); }}); return false; } }); Thank you in advanced! -Dave

    Read the article

  • Function Composition in Haskell

    - by Watts
    I have a function that takes 3 functions and switches the types and combine to make a new function. For example a test case call would be : (chain init tail reverse ) "Haskell!" the output should be lleksa I've tried to do this problem a few different ways including using the map function but I kept getting association problems. so i did chain :: Ord a => [a] -> a chain f g h x = f.g.h$x my error is Couldn't match expected type[t0->t1->t2->a0] When I type the problem directly into prelude like replacing f, g, h, x with the values it comes out right Is there even a way to do three functions, I've only seen two in examples

    Read the article

  • How to see the discharge rate of the battery

    - by Luis Alvarado - The Wolverine
    Maybe this question was made earlier but I can't find it. I want to see a terminal command or gui program that can show me the discharge rate of the battery. What hardware parts or programs are using more watts. EDIT: Found additional information regarding my question when using for example PowerTop: https://bbs.archlinux.org/viewtopic.php?id=128319 https://bugs.archlinux.org/task/26416 Both related to the having disable ACPI_PROCFS_POWER in the kernel.

    Read the article

  • Intel fields six-core embedded CPUs

    <b>LinuxDevices:</b> "The Xeon Processor 5600 series also includes the chipmaker's first six-core embedded processors, plus a dual-core processor for "micro servers" that has a TDP of only 30 Watts, the company says."

    Read the article

  • Can anyone explain these differences between two similar i7 processors? [closed]

    - by Brian Frost
    I have two systems I've just built. They both have i7 processors and Asus P8Z77 motherboards. When I run a simple processor loop benchmark that I wrote in Delphi some time back I get one machine showing nealry twice as fast as the other. I then used CPU-Z to dump me the details of the hardware and I see that the fast machine shows: Processor 1 ID = 0 Number of cores 4 (max 8) Number of threads 8 (max 16) Name Intel Core i7 2700K Codename Sandy Bridge Specification Intel(R) Core(TM) i7-2700K CPU @ 3.50GHz Package (platform ID) Socket 1155 LGA (0x1) CPUID 6.A.7 Extended CPUID 6.2A Core Stepping D2 Technology 32 nm TDP Limit 95 Watts Core Speed 3610.7 MHz Multiplier x FSB 36.0 x 100.3 MHz Stock frequency 3500 MHz the slow machine shows: Processor 1 ID = 0 Number of cores 4 (max 8) Number of threads 8 (max 16) Name Intel Core i7 2600K Codename Sandy Bridge Specification Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz Package (platform ID) Socket 1155 LGA (0x1) CPUID 6.A.7 Extended CPUID 6.2A Core Stepping D2 Technology 32 nm TDP Limit 95 Watts Core Speed 1648.2 MHz Multiplier x FSB 16.0 x 103.0 MHz Stock frequency 3400 MHz i.e the slow machine has a 2600k to the fast machine 2700k. The very different "Multiplier x FSB" must be significant but I dont understand how two processors with a very 'similar' number can be so different. To get the machines the same must I copy the processors or is there some clever setting that I can change? Thanks for any help. Brian.

    Read the article

  • UPS power requirements for server

    - by captainentropy
    Greetings! So, I just placed an order for a new server. The company recommended that I get a 3000W UPS. (!) As best as I could I calculated the following wattage consumption based on benchmarked data or datasheets provided by the manufacturers of each component: number watts **total watts** MoBo 1 240 240 CPUs (E5540) 2 80 160 RAID cards (3ware) 2 18 36 RAM (6x4GB) 6 3 18 DVD drive 1 7 7 floppy 1 2 2 RE4 drives 8 7 56 WD20 drives 8 6 48 Intel X25 SSD 2 0.15 0.3 total = 567 So that is for the PSU requirements only. The PSUs in the machine are a 720W for the master node and 800W each for two subsystems. That's a total of 2320W that can be delivered by these PSUs. But that is 4X the amount being consumed, at most, by the components. I didn't count case fans or the eSATA card (3W maybe?) or what the PSUs themselves require but assuming I double or triple my calculations I'm not even remotely close to the 3000W UPS I was suggested to get. They run at least $1100. I could get a 2000W for about $750 or a 1500W for $450 and still be well over my estimated power need. I don't think I need a whole lot of run time in the case of a power outage, maybe 20 minutes max, enough time to shutdown if the power doesn't come on within 5-10 minutes. Any thoughts? Am I off on my calculations? Did I overlook something major? If so what are your suggestions for a UPS? Thanks!

    Read the article

  • Recommendation for a redundant 60V DC Powersupply

    - by Lairsdragon
    We have some Telco-Equipment in our data space center which we had been given by our Telco. What they didn't provide is a redundant power supply and therefore we are struggling with outages of this equipment. What I am searching for is a redundant Power-Supply for 60V and 600W 60 Volt DC output 600 Watts rated power 2 220V Input with galvanic separation Rack mountable Any suggestions?

    Read the article

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • Super Noob C++ variable help

    - by julian
    Ok, I must preface this by stating that I know so so little about c++ and am hoping someone can just help me out... I have the below code: string GoogleMapControl::CreatePolyLine(RideItem *ride) { std::vector<RideFilePoint> intervalPoints; ostringstream oss; int cp; int intervalTime = 30; // 30 seconds int zone =ride->zoneRange(); if(zone >= 0) { cp = 300; // default cp to 300 watts } else { cp = ride->zones->getCP(zone); } foreach(RideFilePoint* rfp, ride->ride()->dataPoints()) { intervalPoints.push_back(*rfp); if((intervalPoints.back().secs - intervalPoints.front().secs) > intervalTime) { // find the avg power and color code it and create a polyline... AvgPower avgPower = for_each(intervalPoints.begin(), intervalPoints.end(), AvgPower()); // find the color QColor color = GetColor(cp,avgPower); // create the polyline CreateSubPolyLine(intervalPoints,oss,color); intervalPoints.clear(); intervalPoints.push_back(*rfp); } } return oss.str(); } void GoogleMapControl::CreateSubPolyLine(const std::vector<RideFilePoint> &points, std::ostringstream &oss, QColor color) { oss.precision(6); QString colorstr = color.name(); oss.setf(ios::fixed,ios::floatfield); oss << "var polyline = new GPolyline(["; BOOST_FOREACH(RideFilePoint rfp, points) { if (ceil(rfp.lat) != 180 && ceil(rfp.lon) != 180) { oss << "new GLatLng(" << rfp.lat << "," << rfp.lon << ")," << endl; } } oss << "],\"" << colorstr.toStdString() << "\",4);"; oss << "GEvent.addListener(polyline, 'mouseover', function() {" << endl << "var tooltip_text = 'Avg watts:" << avgPower <<" <br> Avg Speed: <br> Color: "<< colorstr.toStdString() <<"';" << endl << "var ss={'weight':8};" << endl << "this.setStrokeStyle(ss);" << endl << "this.overlay = new MapTooltip(this,tooltip_text);" << endl << "map.addOverlay(this.overlay);" << endl << "});" << endl << "GEvent.addListener(polyline, 'mouseout', function() {" << endl << "map.removeOverlay(this.overlay);" << endl << "var ss={'weight':5};" << endl << "this.setStrokeStyle(ss);" << endl << "});" << endl; oss << "map.addOverlay (polyline);" << endl; } And I'm trying to get the avgPower from this part: AvgPower avgPower = for_each(intervalPoints.begin(), intervalPoints.end(), AvgPower()); the first part to cary over to the second part: << "var tooltip_text = 'Avg watts:" << avgPower <<" <br> Avg Speed: <br> Color: "<< colorstr.toStdString() <<"';" << endl But of course I haven't the slightest clue how to do it... anyone feeling generous today? Thanks in advance

    Read the article

  • Functional or non-functional requirement?

    - by killer_PL
    I'm wondering about functional or non-functional requirements. I have found lot of different definitions for those terms and I can't assign some of my requirement to proper category. I'm wondering about requirements that aren't connected with some action or have some additional conditions, for example: On the list of selected devices, device can be repeated. Database must contain at least 100 items Currency of some value must be in USD dollar. Device must have a name and power consumption value in Watts. are those requirements functional or non-functional ?

    Read the article

  • What Exactly Does the Wattage Rating on a Power Supply Unit Mean?

    - by Jason Fitzpatrick
    Your PSU is rated 80 Plus Bronze and for 650 watts, but what exactly does that mean? Read on to see how wattage and power efficiency ratings translate to real world use. Today’s Question & Answer session comes to us courtesy of SuperUser—a subdivision of Stack Exchange, a community-drive grouping of Q&A web sites. How To Use USB Drives With the Nexus 7 and Other Android Devices Why Does 64-Bit Windows Need a Separate “Program Files (x86)” Folder? Why Your Android Phone Isn’t Getting Operating System Updates and What You Can Do About It

    Read the article

  • What is the reason for high power consumption in 12.04?

    - by tom
    I haven't seen this exact question posted or any related answers, so I'm re-posting. Here is the problem: After upgrading to Ubuntu 12.04 Precise Pangolin, my t420s laptop idles above 20 watts (right now with only Chrome running, I'm using 25.4 W) I had a similar problem with Ubuntu 11.10, but after much tweaking the power consumption came down < 10 W on idle. The primary culprit to the 11.10 problem was supposedly fixed by default in 12.04. So my question is, what is happening now? Computer: Lenovo Thinkpad t420s, with Intel i5-2520M @2.5 Ghz - 2x 4gb ram - disk 0 HITACHI 320 Gb - disk 1 SATA SSD 128 Gb

    Read the article

  • diagnosing random power down crashes on a hackintosh [closed]

    - by Iain
    I have a hackintosh running on a Gigabyte P55M UD2. It has run without a single issue as a hackintosh for about 9 months, and the machine is about 2.75 years old. Never had issues when it was just linux box. Power supply is 750 Watts. It recently started spontaneously rebooting, no seeming connected to any particular use case or ram/cpu load. There is no hanging or anything, just suddenly acts like the power went out. The frequency of which seems to be increasing. I've tried using just one of each of the two ram sticks, and it happens with either one in. I'm not sure what to try next, is there some way of determinging whether it's a mobo, cpu, or powersupply issue short of replacing them all? thanks! Iain

    Read the article

  • attach two hdds to a computer having 500W smps

    - by Gaurav Sharma
    I have a desktop system installed with a 250 GB hdd (seagate sata II) this system is having a power supply of 500W (not sure if it is 650W but not more than that) the power supply is a local brand. Will it be safe to attach a second 250 GB sata II hdd on the same system. Safe in the sense that the system may not fall short of power at any time. My system's config is as follows Core2Duo processor Mercury cabinet having an additional fan (small one) sata dvd writer 52X windows xp sp 2 ASUS motherboard (intel G965 express chipset) If the above specified power supply is not sufficient for above configuration of system then please suggest the appropriate power supply (including watts)

    Read the article

  • How to turn off power metering in HP ILO2?

    - by Baron Throw
    I have an issue with all of my RHEL 5.3 servers, where HP iLo2 power meter checks the power draw of the power supply on the server. However this gets passed to the /var/log/messages in our host, and eventually fills up the logs. Anyone have any idea how to completely disable power meter option in iLo? I checked google and iLo2 documentation provided from HP, but found nothing that tells you how to disable it / turn it off. Maybe some CLI command? Im not sure. The message is: Aug 18 10:11:03 KAMIL-SERVER1 ipstor_hwmond: IPSTOR||1408371063||E||11788||sensors||Power Meter = 108.000 Watts [ low=na high=na]

    Read the article

< Previous Page | 1 2 3  | Next Page >