  • My SqlComand on SSIS - DataFlow OLE DB Command seems not works

    - by Angel Escobedo
    Hello Im using OLE DB Source for get rows from a dBase IV file and it works, then I split the data and perform a group by with aggregate component. So I obtain a row with two columns with "null" value : CompanyID | CompanyName | SubTotal | Tax | TotalRevenue Null Null 145487 27642.53 173129.53 this success because all rows have been grouped with out taking care about the firsts columns and just Summing the valuable columns, so I need to change that null for default values as CompanyID = "100000000" and CompanyName = "Others". I try use SqlCommand on a OLE DB Command Component : SELECT "10000000" AS RUCCLI , "Otros - Varios" AS RAZCLI FROM RGVCAFAC <property id="1505" name="SqlCommand" dataType="System.String" state="default" isArray="false" description="The SQL command to be executed." typeConverter="" UITypeEditor="Microsoft.DataTransformationServices.Controls.ModalMultilineStringEditor, Microsoft.DataTransformationServices.Controls, Version=10.0.0.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91" containsID="false" expressionType="Notify">SELECT "10000000" AS RUCCLI , "Otros - Varios" AS RAZCLI FROM RGVCAFAC</property> but nothings happens, why? and finally the task finish when the data is inserted on a SQL Server Table. Im using the same connection manager on extracting data and transform. (View Code) <DTS:Property DTS:Name="ConnectionString">Data Source=C:\CONTA\Resocen\Agosto\;Provider=Microsoft.Jet.OLEDB.4.0;Persist Security Info=False;Extended Properties=dBASE IV;</DTS:Property></DTS:ConnectionManager></DTS:ObjectData></DTS:ConnectionManager> all work is on memory, Im not using cache manager connections

    Read the article

  • What is the role of interfaces IOPCServer, IOPCDataItem, IOPCGroup in OPC ( OLE for process control)

    - by Shailesh Jaiswal
    I am currently new in OPC ( OLE for process control). I want to know about the interfaces IOPCServer, IOPCDataItem, IOPCGroup interfaces in the OPC. What are they used for & what is their role in terms of OPC Client & OPC Server & what methods & properties these interfaces conatins ? Can you provide me the answer for the above questions or can you provide me the link through which I can get the knowledge of the above topics ?

    Read the article

  • Delphi - COM/OLE starting example needed

    - by durumdara
    Hi! 10 years have ellapsed since I used COM/OLE, and I forget 90% of them. Now we need to make a COM object to access some data from PHP/Python (this is specific thing, the php ODBC don't access the output params of a DataBase - like stored proc output), and my idea the I realize a minimal object with one method, and PHP/Python can call this to get the output... procedure ExecSQL(Config, IP, Port, DBName, SQL, IDFieldName : variant) : output output is [IDValue, ErrorMsg, HResult] Please help me a very little example, how to start it? I need only this, but I'm confused by many ActiveX/COM in the palette. What I need to use to make a simple COM DLL, and how to register my COM object with this DLL? Thanks: dd

    Read the article

  • What's the recommended implemenation for hashing OLE Variants?

    - by Barry Kelly
    OLE Variants, as used by older versions of Visual Basic and pervasively in COM Automation, can store lots of different types: basic types like integers and floats, more complicated types like strings and arrays, and all the way up to IDispatch implementations and pointers in the form of ByRef variants. Variants are also weakly typed: they convert the value to another type without warning depending on which operator you apply and what the current types are of the values passed to the operator. For example, comparing two variants, one containing the integer 1 and another containing the string "1", for equality will return True. So assuming that I'm working with variants at the underlying data level (e.g. VARIANT in C++ or TVarData in Delphi - i.e. the big union of different possible values), how should I hash variants consistently so that they obey the right rules? Rules: Variants that hash unequally should compare as unequal, both in sorting and direct equality Variants that compare as equal for both sorting and direct equality should hash as equal It's OK if I have to use different sorting and direct comparison rules in order to make the hashing fit. The way I'm currently working is I'm normalizing the variants to strings (if they fit), and treating them as strings, otherwise I'm working with the variant data as if it was an opaque blob, and hashing and comparing its raw bytes. That has some limitations, of course: numbers 1..10 sort as [1, 10, 2, ... 9] etc. This is mildly annoying, but it is consistent and it is very little work. However, I do wonder if there is an accepted practice for this problem.

    Read the article

  • What's the recommended implementation for hashing OLE Variants?

    - by Barry Kelly
    OLE Variants, as used by older versions of Visual Basic and pervasively in COM Automation, can store lots of different types: basic types like integers and floats, more complicated types like strings and arrays, and all the way up to IDispatch implementations and pointers in the form of ByRef variants. Variants are also weakly typed: they convert the value to another type without warning depending on which operator you apply and what the current types are of the values passed to the operator. For example, comparing two variants, one containing the integer 1 and another containing the string "1", for equality will return True. So assuming that I'm working with variants at the underlying data level (e.g. VARIANT in C++ or TVarData in Delphi - i.e. the big union of different possible values), how should I hash variants consistently so that they obey the right rules? Rules: Variants that hash unequally should compare as unequal, both in sorting and direct equality Variants that compare as equal for both sorting and direct equality should hash as equal It's OK if I have to use different sorting and direct comparison rules in order to make the hashing fit. The way I'm currently working is I'm normalizing the variants to strings (if they fit), and treating them as strings, otherwise I'm working with the variant data as if it was an opaque blob, and hashing and comparing its raw bytes. That has some limitations, of course: numbers 1..10 sort as [1, 10, 2, ... 9] etc. This is mildly annoying, but it is consistent and it is very little work. However, I do wonder if there is an accepted practice for this problem.

    Read the article

  • How to mark multiple coordinates in KML using Java?

    - by Akshay
    I'm working on a project that involves KML creation using Java. Currently, I'm fooling with the sample Java code from the KML example at Micromata Labs JAK Example. I tried to "extend" the code by adding multiple coordinates and getting two markers, but I could not get it to work. Can you please tell me how I can add multiple coordinates and put markers on them, and also, draw a line between the markers. Thank you for your help! PS: I need to do this via the program. I saw sample code of them using DOM and XML, but not pure Java/JAK as such. Please guide me. I got as far as this: kml .createAndSetDocument().withName("My Markers"). createAndAddPlacemark().withName("London, UK").withOpen(Boolean.TRUE) .createAndSetPoint().addToCoordinates(-0.126236, 51.500152); kml.createAndSetPlacemark() .withName("Somewhere near London, UK").withOpen(Boolean.TRUE) .createAndSetPoint().addToCoordinates(-0.129800,52.700152); But I know I'm going wrong somewhere. Please point me in the right direction.

    Read the article

  • Disable script debugging in IWebBrowser2 OLE control? C++

    - by flyout
    I have a IWebBrowser2 I use to visit some webpages with .Navigate() When the page has a js error I got a warning box for "Syntax error", so I used .put_Silent(TRUE). And now I get a warning for "VS Just-In-Time Debugger: Unhandled exception" instead How can I disable all the script error warnings (including JIT debugger) from my code (i mean without modifying the real IE settings)?

    Read the article

  • Microsoft OLE DB Provider for SQL Server error '80040e14' Could not find stored procedure

    - by BBlake
    I am migrating a classic ASP web app to new servers. The database back end is migrating from SQL Server 2000 to SQL Server 2008, and the app is moving from Win2000 x86 to Win2003R2 x64. I am getting the above error on every single stored procedure call within the application. I have verified: Yes, the SQL user is set up, using correct username and password Yes, the SQL user has execute permissions on the stored procedures in the database Yes, I have updated the TypeLib references to the new UUID Yes, I have logged into the database via SSMS with the SQL user id and it can see and execute the stored procedures just fine in SSMS, but not from the web app. Yes, the SQL user has the database set as its default database. The most frustrating thing is it works fine on the DEV server, but not on the production server. I have gone through every IIS setting 5 or 6 times and the web app is set up precisely the same in both environments. The only difference is the database server name in the connection string (DEV vs prod) EDIT: I have also tried pointing the prod web box at the dev database server and get the same error so I'm fairly sure the issue isn't on the database side.

    Read the article

  • std::ostream interface to an OLE IStream

    - by PaulH
    I have a Visual Studio 2008 C++ application using IStreams. I would like to use the IStream connection in a std::ostream. Something like this: IStream* stream = /*create valid IStream instance...*/; IStreamBuf< WIN32_FIND_DATA > sb( stream ); std::ostream os( &sb ); WIN32_FIND_DATA d = { 0 }; // send the structure along the IStream os << d; To accomplish this, I've implemented the following code: template< class _CharT, class _Traits > inline std::basic_ostream< _CharT, _Traits >& operator<<( std::basic_ostream< _CharT, _Traits >& os, const WIN32_FIND_DATA& i ) { const _CharT* c = reinterpret_cast< const _CharT* >( &i ); const _CharT* const end = c + sizeof( WIN32_FIND_DATA ) / sizeof( _CharT ); for( c; c < end; ++c ) os << *c; return os; } template< typename T > class IStreamBuf : public std::streambuf { public: IStreamBuf( IStream* stream ) : stream_( stream ) { setp( reinterpret_cast< char* >( &buffer_ ), reinterpret_cast< char* >( &buffer_ ) + sizeof( buffer_ ) ); }; virtual ~IStreamBuf() { sync(); }; protected: traits_type::int_type FlushBuffer() { int bytes = std::min< int >( pptr() - pbase(), sizeof( buffer_ ) ); DWORD written = 0; HRESULT hr = stream_->Write( &buffer_, bytes, &written ); if( FAILED( hr ) ) { return traits_type::eof(); } pbump( -bytes ); return bytes; }; virtual int sync() { if( FlushBuffer() == traits_type::eof() ) return -1; return 0; }; traits_type::int_type overflow( traits_type::int_type ch ) { if( FlushBuffer() == traits_type::eof() ) return traits_type::eof(); if( ch != traits_type::eof() ) { *pptr() = ch; pbump( 1 ); } return ch; }; private: /// data queued up to be sent T buffer_; /// output stream IStream* stream_; }; // class IStreamBuf Yes, the code compiles and seems to work, but I've not had the pleasure of implementing a std::streambuf before. So, I'd just like to know if it's correct and complete. Thanks, PaulH

    Read the article

  • How to catch a moment when the external editor of TOLEContainer has been closed?

    - by Andrew
    Borland Developer Studio 2006, Delphi: I have a TOLEContainer object with AllowInPlace=False. When the external editor is closed and changed my OLE object I have to do something with this OLE object inside TOLeContainer. The problem is I can't catch a moment when the external editor is closed. OnDeactivate event is not working. Probably I should change the source code of TOLEContainer adding this event myself, but I don't know where is the best place for it. Can you advice some method?

    Read the article

  • SSIS 2005 Error while using script component Designer: "Cannot fetch a row from OLE DB provider "BUL

    - by user150541
    I am trying to debug a dts package in SSIS. I have a script component designer where I pass in the input variables to increment a counter. When I try to msgbox the counter value, I get the following error. Error: 0xC0202009 at STAGING1 to STAGING2, STAGING2 Destination [1056]: An OLE DB error has occurred. Error code: 0x80040E14. An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80040E14 Description: "Cannot fetch a row from OLE DB provider "BULK" for linked server "(null)".". An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80040E14 Description: "The OLE DB provider "BULK" for linked server "(null)" reported an error. The provider did not give any information about the error.". An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80040E14 Description: "Reading from DTS buffer timed out.". Below is the part of the code within the script component designer : Imports System Imports System.Data Imports System.Math Imports Microsoft.SqlServer.Dts.Pipeline.Wrapper Imports Microsoft.SqlServer.Dts.Runtime.Wrapper Public Class ScriptMain Inherits UserComponent Dim iCounter As Integer Dim iCurrentVal As Integer Dim sCurrentOracleSeq As String Dim sSeqName As String Dim sSeqAltProcName As String Public Overrides Sub Input0_ProcessInputRow(ByVal Row As Input0Buffer) ' ' Add your code here ' Row.SEQIDNCASE = iCounter + iCurrentVal iCounter += 1 MsgBox(iCounter + iCurrentVal, MsgBoxStyle.Information, "Input0") End Sub Public Overrides Sub PreExecute() sCurrentOracleSeq = Me.Variables.VSEQIDCurVal iCurrentVal = CInt(sCurrentOracleSeq) MsgBox(iCurrentVal, MsgBoxStyle.Information, "No Title") iCounter = 0 sSeqName = Me.Variables.VSEQIDName sSeqAltProcName = Me.Variables.VSEQIDAlterProc End Sub Public Overrides Sub PostExecute() Me.Variables.VSEQIDUpdateSQL = "Begin " & sSeqAltProcName & "('" & sSeqName & "'," & (iCounter + iCurrentVal) & "); End;" End Sub End Class Note that the above part of code works perfectly fine if I comment out the lines that has Msgbox.

    Read the article

  • Problems with native Win32api RichEdit control and its IRichEditOle interface

    - by Michael
    Hi All! As part of writing custom command (dll with class that implements Interwoven command interface) for one of Interwoven Worksite dialog boxes,I need to extract information from RichEdit textbox. The only connection to the existing dialog box is its HWND handle; Seemingly trivial task , but I got stuck : Using standard win32 api functions (like GetDlgItemText) returns empty string. After using Spy++ I noticed that the dialog box gets IRichEditOle interface and seems to encapsulate the string into OLE object. Here is what I tried to do: IRichEditOle richEditOleObj = null; IntPtr ppv = IntPtr.Zero; Guid guid = new Guid("00020D00-0000-0000-c000-000000000046"); Marshal.QueryInterface(pRichEdit, ref guid, out ppv); richEditOleObj = (IRichEditOle)Marshal.GetTypedObjectForIUnknown(ppv,typeof(IRichEditOle)); judging by GetObjectCount() method of the interface there is exactly one object in the textbox - most likely the string I need to extract. I used GetObject() method and got IOleObject interface via QueryInterface : if (richEditOleObj.GetObject(0, reObject, GetObjectOptions.REO_GETOBJ_ALL_INTERFACES) == 0) //S_OK { IntPtr oleObjPpv = IntPtr.Zero; try { IOleObject oleObject = null; Guid objGuid = new Guid("00000112-0000-0000-C000-000000000046"); Marshal.QueryInterface(reObject.poleobj, ref objGuid, out oleObjPpv); oleObject = (IOleObject)Marshal.GetTypedObjectForIUnknown(oleObjPpv, typeof(IOleObject)); To negate other possibilites I tried to QueryInteface IRichEditOle to ITextDocument but this also returned empty string; tried to send EM_STREAMOUT message and read buffer returned from callback - returned empty buffer. And on this point I got stuck. Googling didn't help much - couldn't find anything that was relevant to my issue - it seems that vast majority of examples on the net about IRichEditOle and RichEdit revolve around inserting bitmap into RichEdit control... Now since I know only basic stuff about COM and OLE , I guess I am missing something important here. I would appreciate any thoughts suggestions or remarks.

    Read the article

  • How to link to an Excel pivot table that will expand over time in Word 2007?

    - by Daljit Dhadwal
    I have a pivot table in Excel 2007 which I’ve pasted it into Word 2007 using Paste Special (Paste link) - Microsoft Office Excel Worksheet Object. The pivot table appears in Word and the link to Excel is working. The problem is that if the pivot table expands (for example, due to showing 12 months of data rather than six months) the link to the pivot table in Word will only show the range cells that were originally copied over with the pivot table. I understand why this happens. When I paste as a link to Word the underling field codes look like this: {LINK Excel.Sheet.8 "C:\Users\myAccount\Documents\testexcel.xlsx" "Sheet2!R1C1:R8C2" \a \p} The codes refer to a fixed area (e.g., Sheet2!R1C1:R8C2 ) of the Excel spreadsheet, and so when the pivot table expands, the expanded cells fall outside the area that is defined in the field codes. Is there some way to have the link refer to the pivot table itself rather than the cell range that happened to be originally copied over from Excel?

    Read the article

  • The OLE DB provider "SQLNCLI10.1" has not been registered.; 42000.

    - by lankylad
    I have a SQL Server 2008 Analysis Services Project. In the Data Source View I have a Named Query which references a single Data Source containing three tables. The Project processes successfully and the cube can be browsed. I recently added a second Data Source to the Data Source View and linked a table to the original Named Query. When I try to process the project, I get the message: OLE DB error: OLE DB or ODBC error: The OLE DB provider "SQLNCLI10.1" has not been registered.; 42000. The Connection String for both Data Sources uses SQLNCLI10.1

    Read the article

  • The OLE DB provider "SQLNCLI10.1" has not been registered.; 42000

    - by lankylad
    I have a SQL Server 2008 Analysis Services Project. In the Data Source View I have a Named Query which references a single Data Source containing three tables. The Project processes successfully and the cube can be browsed. I recently added a second Data Source to the Data Source View and linked a table to the original Named Query. When I try to process the project, I get the message: OLE DB error: OLE DB or ODBC error: The OLE DB provider "SQLNCLI10.1" has not been registered.; 42000. The Connection String for both Data Sources uses SQLNCLI10.1

    Read the article

  • Can a program that controls IE detect if a HTTP 30x code is encountered?

    - by hillu
    I am trying to control an InternetExplorer.Application via the COM interface, using Perl, Win32::OLE, and information from MSDN. My goal is to get as good an idea as possible about what IE is doing. (Related to this question.) IE uses events to notify my program when it has finished various stages of processing a certain URL (NavigateComplete2, DownloadComplete DocumentComplete). It can also tell my program about various errors it encounters (NavigateError2). I consider that part of my problem solved well enough. I would also like to be able to reliably detect if IE is redirected by the server. Primarily, I'm concerned about HTTP 30x status codes. Is there a way to do this, either with COM automation or via another route?

    Read the article

  • Using a indentifier or reserved word in a automation object under FPC

    - by Salvador
    Actually i am using OLE automation under Free Pascal , but some objects have properties which uses reserverd words as names, so i cannot compile the code. check this sample MyObj : OleVariant; begin MyObj := CrealeOleObject('AObject'); MyObj .Descriptor := Param1; MyObj .Type := Param2; //this line generates a error this is the error StdOleAux.pas(783,15) Fatal: Syntax error, "identifier" expected but "TYPE" found so the question is how i can access this properties in FPC when they have a name which is a reserved word? FPC 2.2.4 Lazarus 0.9.28.2 using {$MODE DELPHI}

    Read the article

  • SQL SERVER – Fix Error: Microsoft OLE DB Provider for SQL Server error ’80040e07' or Microsoft SQL Native Client error ’80040e07'

    - by pinaldave
    I quite often receive questions where users are looking for solution to following error: Microsoft OLE DB Provider for SQL Server error ’80040e07′ Syntax error converting datetime from character string. OR Microsoft SQL Native Client error ’80040e07′ Syntax error converting datetime from character string. If you have ever faced above error – I have a very simple solution for you. The solution is being very check date which is inserted in the datetime column. This error often comes up when application or user is attempting to enter an incorrect date into the datetime field. Here is one of the examples – one of the reader was using classing ASP Application with OLE DB provider for SQL Server. When he tried to insert following script he faced above mentioned error. INSERT INTO TestTable (ID, MyDate) VALUES (1, '01-Septeber-2013') The reason for the error was simple as he had misspelled September word. Upon correction of the word, he was able to successfully insert the value and error was not there. Incorrect values or the typo’s are not the only reason for this error. There can be issues with cast or convert as well. If you try to attempt following code using SQL Native Client or in your application you will also get similar errors. SELECT CONVERT (datetime, '01-Septeber-2013', 112) The reason here is very simple, any conversion attempt or any other kind of operation on incorrect date/time string can lead to the above error. If you not using embeded dynamic code in your application language but using attempting similar operation on incorrect datetime string you will get following error. Msg 241, Level 16, State 1, Line 2 Conversion failed when converting date and/or time from character string. Remember: Check your values of the string when you are attempting to convert them to string – either there can be incorrect values or they may be incorrectly formatted. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL DateTime, SQL Error Messages, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Interface Marshalling in Delphi

    - by cemick
    I want to send Interface Ref of IVApplication from Visio Add-in to my other one COM server. But I have Ole exception. Now i do that: Code in Visio Add-in: var IStrm: IStream; hres: HResult; rhglobal: HGLOBAL; VisioAppl: IVApplication; begin hres := CreateStreamOnHGlobal(0, TRUE, IStrm); if Succeeded(hres) then hres := CoMarshalInterface(IStrm, IID_IVApplication, VisioAppl, MSHCTX_LOCAL, 0, MSHLFLAGS_NORMAL); if (Succeeded(hres)) then begin hres := GetHGlobalFromStream(IStrm, rhglobal); IStrm := nil; end; end; After this I create instance of my COM server and pass rhglobal to him. Code of my COM server: procedure (AHGlobal: HGlobal); var VisioAppl: Visio_TLB.IVApplication; iStrm: IStream; hres: HResult; begin iStrm := Nil; VisioAppl:= nil; hres := CreateStreamOnHGlobal(AHGlobal, FALSE, iStrm); if (SUCCEEDED(hres)) then begin hres := CoUnmarshalInterface(iStrm, Visio_TLB.IVApplication, VisioAppl); iStrm := nil; ShowMessage('Result:' + BoolToStr(SUCCEEDED(hres))); <-- result 0 ShowMessage(VisioAppl.ProductName); <---- Error end; end;

    Read the article

  • Pass object from webserver to client

    - by user362914
    I developed a C# web application that calls a web-service which returns a base64 encoded array (PDF file). I then convert that array into a UCOMIStream object (I know it is obsolete, but the DLL that I am using requires it as a parameter). I use the following code to do the conversion which works perfectly. I can pass this object to the DLL so that I can print the PDF. This works great on the Webserver, but the requirement is to print it locally. Byte[] bBuffer = statementOut.statementcycle.statementdata.content; int size = bBuffer.Length; IntPtr mem = Marshal.AllocHGlobal(size); Marshal.Copy(bBuffer, 0, mem, size); // Create an OLE Stream object. System.Runtime.InteropServices.UCOMIStream str; //obsolete but the createstreamonhglobal outputs it CreateStreamOnHGlobal(mem, true, out str); The DLL resides on the client so I am able to use ActiveX to create the object using javascript and/or VBscript;however, I have not been able to figure out how to get the stream object to the client to pass to the DLL. How can this be achieved?

    Read the article

  • The application called an interface that was marshalled for a different thread

    - by X-Ray
    i'm writing a delphi app that communicates with excel. one thing i noticed is that if i call the Save method on the Excel workbook object, it can appear to hang because excel has a dialog box open for the user. i'm using the late binding. i'd like for my app to be able to notice when Save takes several seconds and then take some kind of action like show a dialog box telling this is what's happening. i figured this'd be fairly easy. all i'd need to do is create a thread that calls Save and have that thread call Excel's Save routine. if it takes too long, i can take some action. procedure TOfficeConnect.Save; var Thread:TOfficeHangThread; begin // spin off as thread so we can control timeout Thread:=TOfficeSaveThread.Create(m_vExcelWorkbook); if WaitForSingleObject(Thread.Handle, 5 {s} * 1000 {ms/s})=WAIT_TIMEOUT then begin Thread.FreeOnTerminate:=true; raise Exception.Create(_('The Office spreadsheet program seems to be busy.')); end; Thread.Free; end; TOfficeSaveThread = class(TThread) private { Private declarations } m_vExcelWorkbook:variant; protected procedure Execute; override; procedure DoSave; public constructor Create(vExcelWorkbook:variant); end; { TOfficeSaveThread } constructor TOfficeSaveThread.Create(vExcelWorkbook:variant); begin inherited Create(true); m_vExcelWorkbook:=vExcelWorkbook; Resume; end; procedure TOfficeSaveThread.Execute; begin m_vExcelWorkbook.Save; end; i understand this problem happens because the OLE object was created from another thread (absolutely). how can i get around this problem? most likely i'll need to "re-marshall" for this call somehow... any ideas? thank you!

    Read the article

  • Convert RGB Colour to OLE_Color

    - by Robert W
    I have the unenviable task of maintaining an ActiveX control that expects OLE_Colors as the back/for colour of the control. Is there a tool or a .NET code sample that will convert from an RGB colour (or a hex colour) to an OLE_Color?

    Read the article