Search Results

Search found 3617 results on 145 pages for 'physical wear'.

Page 2/145 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Is there a Generic USB TouchScreen Driver 12.04?

    - by lbjoum
    Is there a Generic USB TouchScreen Driver 12.04? Device 03eb:201c I've been looking for 4 days solid (not very skilled) and can't find a solution. I have a generic tablet: C97- Atom N2600 9.7" 2GB 32GB Bluetooth WiFi WebCam Ext.3G Windows 7 Tablet PC Using 12.04 and cannot find a driver. I installed android and the touchscreen works but still lots of other bugs. Oh well, stuck with Windows 7 and not happy about it. Will keep trying, but too much time wasted already. If you have a solution I would love to try it. ubuntu@ubuntu:~$ lsusb Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 0cf2:6238 ENE Technology, Inc. Bus 001 Device 003: ID 1a40:0101 Terminus Technology Inc. 4-Port HUB Bus 001 Device 005: ID 05e1:0100 Syntek Semiconductor Co., Ltd 802.11g + Bluetooth Wireless Adapter Bus 001 Device 006: ID 090c:3731 Silicon Motion, Inc. - Taiwan (formerly Feiya Technology Corp.) Bus 003 Device 002: ID 03eb:201c Atmel Corp. at90usbkey sample firmware (HID mouse) (from Windows: HID\VID_03EB&PID_201C\6&5F38127&0&0000 USB\VID_03EB&PID_201C\5&193ADADC&1&2 ) Bus 001 Device 007: ID 0518:0001 EzKEY Corp. USB to PS2 Adaptor v1.09 Bus 001 Device 008: ID 192f:0916 Avago Technologies, Pte. ubuntu@ubuntu:~$ sudo lsusb -v Bus 003 Device 002: ID 03eb:201c Atmel Corp. at90usbkey sample firmware (HID mouse) Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 32 idVendor 0x03eb Atmel Corp. idProduct 0x201c at90usbkey sample firmware (HID mouse) bcdDevice 45.a2 iManufacturer 1 CDT iProduct 2 9.75 iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 34 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0x00 (Missing must-be-set bit!) (Bus Powered) MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 0 No Subclass bInterfaceProtocol 0 None iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.11 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 177 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0020 1x 32 bytes bInterval 5 Device Status: 0x00fb Self Powered Remote Wakeup Enabled Debug Mode ubuntu@ubuntu:~$ sudo lshw ubuntu description: Notebook product: To be filled by O.E.M. (To be filled by O.E.M.) vendor: To be filled by O.E.M. version: To be filled by O.E.M. serial: To be filled by O.E.M. width: 32 bits capabilities: smbios-2.7 dmi-2.7 smp-1.4 smp configuration: boot=normal chassis=notebook cpus=2 family=To be filled by O.E.M. sku=To be filled by O.E.M. uuid=00020003-0004-0005-0006-000700080009 *-core description: Motherboard product: Tiger Hill vendor: INTEL Corporation physical id: 0 version: To be filled by O.E.M. serial: To be filled by O.E.M. slot: To be filled by O.E.M. *-firmware description: BIOS vendor: American Megatrends Inc. physical id: 0 version: 4.6.5 date: 08/24/2012 size: 64KiB capacity: 960KiB capabilities: pci upgrade shadowing cdboot bootselect socketedrom edd int13floppy1200 int13floppy720 int13floppy2880 int5printscreen int9keyboard int14serial int17printer acpi usb biosbootspecification *-cpu:0 description: CPU product: Intel(R) Atom(TM) CPU N2600 @ 1.60GHz vendor: Intel Corp. physical id: 4 bus info: cpu@0 version: 6.6.1 serial: 0003-0661-0000-0000-0000-0000 slot: CPU 1 size: 1600MHz capacity: 1600MHz width: 64 bits clock: 400MHz capabilities: x86-64 boot fpu fpu_exception wp vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx constant_tsc arch_perfmon pebs bts nonstop_tsc aperfmperf pni dtes64 monitor ds_cpl est tm2 ssse3 cx16 xtpr pdcm movbe lahf_lm arat configuration: cores=2 enabledcores=1 id=2 threads=2 *-cache:0 description: L1 cache physical id: 5 slot: L1-Cache size: 24KiB capacity: 24KiB capabilities: internal write-back unified *-cache:1 description: L2 cache physical id: 6 slot: L2-Cache size: 512KiB capacity: 512KiB capabilities: internal varies unified *-logicalcpu:0 description: Logical CPU physical id: 2.1 width: 64 bits capabilities: logical *-logicalcpu:1 description: Logical CPU physical id: 2.2 width: 64 bits capabilities: logical *-logicalcpu:2 description: Logical CPU physical id: 2.3 width: 64 bits capabilities: logical *-logicalcpu:3 description: Logical CPU physical id: 2.4 width: 64 bits capabilities: logical *-memory description: System Memory physical id: 28 slot: System board or motherboard size: 2GiB *-bank:0 description: SODIMM [empty] product: [Empty] vendor: [Empty] physical id: 0 serial: [Empty] slot: DIMM0 *-bank:1 description: SODIMM DDR3 Synchronous 800 MHz (1.2 ns) vendor: 69 physical id: 1 serial: 00000210 slot: DIMM1 size: 2GiB width: 64 bits clock: 800MHz (1.2ns) *-cpu:1 physical id: 1 bus info: cpu@1 version: 6.6.1 serial: 0003-0661-0000-0000-0000-0000 size: 1600MHz capabilities: ht configuration: id=2 *-logicalcpu:0 description: Logical CPU physical id: 2.1 capabilities: logical *-logicalcpu:1 description: Logical CPU physical id: 2.2 capabilities: logical *-logicalcpu:2 description: Logical CPU physical id: 2.3 capabilities: logical *-logicalcpu:3 description: Logical CPU physical id: 2.4 capabilities: logical *-pci description: Host bridge product: Atom Processor D2xxx/N2xxx DRAM Controller vendor: Intel Corporation physical id: 100 bus info: pci@0000:00:00.0 version: 03 width: 32 bits clock: 33MHz *-display UNCLAIMED description: VGA compatible controller product: Atom Processor D2xxx/N2xxx Integrated Graphics Controller vendor: Intel Corporation physical id: 2 bus info: pci@0000:00:02.0 version: 09 width: 32 bits clock: 33MHz capabilities: pm msi vga_controller bus_master cap_list configuration: latency=0 resources: memory:dfe00000-dfefffff ioport:f100(size=8) *-multimedia description: Audio device product: N10/ICH 7 Family High Definition Audio Controller vendor: Intel Corporation physical id: 1b bus info: pci@0000:00:1b.0 version: 02 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:42 memory:dff00000-dff03fff *-pci:0 description: PCI bridge product: N10/ICH 7 Family PCI Express Port 1 vendor: Intel Corporation physical id: 1c bus info: pci@0000:00:1c.0 version: 02 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:40 ioport:2000(size=4096) memory:80000000-801fffff ioport:80200000(size=2097152) *-usb:0 description: USB controller product: N10/ICH 7 Family USB UHCI Controller #1 vendor: Intel Corporation physical id: 1d bus info: pci@0000:00:1d.0 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:23 ioport:f0a0(size=32) *-usb:1 description: USB controller product: N10/ICH 7 Family USB UHCI Controller #2 vendor: Intel Corporation physical id: 1d.1 bus info: pci@0000:00:1d.1 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:19 ioport:f080(size=32) *-usb:2 description: USB controller product: N10/ICH 7 Family USB UHCI Controller #3 vendor: Intel Corporation physical id: 1d.2 bus info: pci@0000:00:1d.2 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:18 ioport:f060(size=32) *-usb:3 description: USB controller product: N10/ICH 7 Family USB UHCI Controller #4 vendor: Intel Corporation physical id: 1d.3 bus info: pci@0000:00:1d.3 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:16 ioport:f040(size=32) *-usb:4 description: USB controller product: N10/ICH 7 Family USB2 EHCI Controller vendor: Intel Corporation physical id: 1d.7 bus info: pci@0000:00:1d.7 version: 02 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:23 memory:dff05000-dff053ff *-pci:1 description: PCI bridge product: 82801 Mobile PCI Bridge vendor: Intel Corporation physical id: 1e bus info: pci@0000:00:1e.0 version: e2 width: 32 bits clock: 33MHz capabilities: pci subtractive_decode bus_master cap_list *-isa description: ISA bridge product: NM10 Family LPC Controller vendor: Intel Corporation physical id: 1f bus info: pci@0000:00:1f.0 version: 02 width: 32 bits clock: 33MHz capabilities: isa bus_master cap_list configuration: latency=0 *-storage description: SATA controller product: N10/ICH7 Family SATA Controller [AHCI mode] vendor: Intel Corporation physical id: 1f.2 bus info: pci@0000:00:1f.2 logical name: scsi0 version: 02 width: 32 bits clock: 66MHz capabilities: storage msi pm ahci_1.0 bus_master cap_list emulated configuration: driver=ahci latency=0 resources: irq:41 ioport:f0f0(size=8) ioport:f0e0(size=4) ioport:f0d0(size=8) ioport:f0c0(size=4) ioport:f020(size=16) memory:dff04000-dff043ff *-disk description: ATA Disk product: BIWIN SSD physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/sda version: 1206 serial: 123403501060 size: 29GiB (32GB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 signature=8fbe402b *-volume:0 description: Windows NTFS volume physical id: 1 bus info: scsi@0:0.0.0,1 logical name: /dev/sda1 version: 3.1 serial: 249bde5d-8246-9a40-88c7-2d5e3bcaf692 size: 19GiB capacity: 19GiB capabilities: primary bootable ntfs initialized configuration: clustersize=4096 created=2011-04-04 02:27:51 filesystem=ntfs state=clean *-volume:1 description: Windows NTFS volume physical id: 2 bus info: scsi@0:0.0.0,2 logical name: /dev/sda2 version: 3.1 serial: de12d40f-d5ca-8642-b306-acd9349fda1a size: 10231MiB capacity: 10GiB capabilities: primary ntfs initialized configuration: clustersize=4096 created=2011-04-04 01:52:26 filesystem=ntfs state=clean *-serial UNCLAIMED description: SMBus product: N10/ICH 7 Family SMBus Controller vendor: Intel Corporation physical id: 1f.3 bus info: pci@0000:00:1f.3 version: 02 width: 32 bits clock: 33MHz configuration: latency=0 resources: ioport:f000(size=32) *-scsi:0 physical id: 2 bus info: usb@1:1 logical name: scsi4 capabilities: emulated scsi-host configuration: driver=usb-storage *-disk description: SCSI Disk physical id: 0.0.0 bus info: scsi@4:0.0.0 logical name: /dev/sdb size: 29GiB (31GB) capabilities: partitioned partitioned:dos configuration: signature=00017463 *-volume description: Windows FAT volume vendor: mkdosfs physical id: 1 bus info: scsi@4:0.0.0,1 logical name: /dev/sdb1 logical name: /cdrom version: FAT32 serial: 129b-4f87 size: 29GiB capacity: 29GiB capabilities: primary bootable fat initialized configuration: FATs=2 filesystem=fat mount.fstype=vfat mount.options=rw,relatime,fmask=0022,dmask=0022,codepage=cp437,iocharset=iso8859-1,shortname=mixed,errors=remount-ro state=mounted *-scsi:1 physical id: 3 bus info: usb@1:3.1 logical name: scsi6 capabilities: emulated scsi-host configuration: driver=usb-storage *-disk description: SCSI Disk physical id: 0.0.0 bus info: scsi@6:0.0.0 logical name: /dev/sdc size: 7400MiB (7759MB) capabilities: partitioned partitioned:dos configuration: signature=c3072e18 *-volume description: Windows FAT volume vendor: mkdosfs physical id: 1 bus info: scsi@6:0.0.0,1 logical name: /dev/sdc1 logical name: /media/JOUM8G version: FAT32 serial: e676-9311 size: 7394MiB capacity: 7394MiB capabilities: primary bootable fat initialized configuration: FATs=2 filesystem=fat label=Android mount.fstype=vfat mount.options=rw,nosuid,nodev,relatime,uid=999,gid=999,fmask=0022,dmask=0077,codepage=cp437,iocharset=iso8859-1,shortname=mixed,showexec,utf8,flush,errors=remount-ro state=mounted ubuntu@ubuntu:~$ ubuntu@ubuntu:~$ xinput list ? Virtual core pointer id=2 [master pointer (3)] ? ? Virtual core XTEST pointer id=4 [slave pointer (2)] ? ? Plus More Enterprise LTD. USB-compliant keyboard id=10 [slave pointer (2)] ? ? USB Optical Mouse id=11 [slave pointer (2)] ? Virtual core keyboard id=3 [master keyboard (2)] ? Virtual core XTEST keyboard id=5 [slave keyboard (3)] ? Power Button id=6 [slave keyboard (3)] ? Power Button id=7 [slave keyboard (3)] ? Sleep Button id=8 [slave keyboard (3)] ? Plus More Enterprise LTD. USB-compliant keyboard id=9 [slave keyboard (3)] ? USB 2.0 Webcam - Front id=12 [slave keyboard (3)] ? AT Translated Set 2 keyboard id=13 [slave keyboard (3)] ubuntu@ubuntu:~$

    Read the article

  • Find only physical network adapters with WMI Win32_NetworkAdapter class

    - by Mladen Prajdic
    WMI is Windows Management Instrumentation infrastructure for managing data and machines. We can access it by using WQL (WMI querying language or SQL for WMI). One thing to remember from the WQL link is that it doesn't support ORDER BY. This means that when you do SELECT * FROM wmiObject, the returned order of the objects is not guaranteed. It can return adapters in different order based on logged-in user, permissions of that user, etc… This is not documented anywhere that I've looked and is derived just from my observations. To get network adapters we have to query the Win32_NetworkAdapter class. This returns us all network adapters that windows detect, real and virtual ones, however it only supplies IPv4 data. I've tried various methods of combining properties that are common on all systems since Windows XP. The first thing to do to remove all virtual adapters (like tunneling, WAN miniports, etc…) created by Microsoft. We do this by adding WHERE Manufacturer!='Microsoft' to our WMI query. This greatly narrows the number of adapters we have to work with. Just on my machine it went from 20 adapters to 5. What was left were one real physical Realtek LAN adapter, 2 virtual adapters installed by VMware and 2 virtual adapters installed by VirtualBox. If you read the Win32_NetworkAdapter help page you'd notice that there's an AdapterType that enumerates various adapter types like LAN or Wireless and AdapterTypeID that gives you the same information as AdapterType only in integer form. The dirty little secret is that these 2 properties don't work. They are both hardcoded, AdapterTypeID to "0" and AdapterType to "Ethernet 802.3". The only exceptions I've seen so far are adapters that have no values at all for the two properties, "RAS Async Adapter" that has values of AdapterType = "Wide Area Network" and AdapterTypeID = "3" and various tunneling adapters that have values of AdapterType = "Tunnel" and AdapterTypeID = "15". In the help docs there isn't even a value for 15. So this property was of no help. Next property to give hope is NetConnectionId. This is the name of the network connection as it appears in the Control Panel -> Network Connections. Problem is this value is also localized into various languages and can have different names for different connection. So both of these properties don't help and we haven't even started talking about eliminating virtual adapters. Same as the previous one this property was also of no help. Next two properties I checked were ConfigManagerErrorCode and NetConnectionStatus in hopes of finding disabled and disconnected adapters. If an adapter is enabled but disconnected the ConfigManagerErrorCode = 0 with different NetConnectionStatus. If the adapter is disabled it reports ConfigManagerErrorCode = 22. This looked like a win by using (ConfigManagerErrorCode=0 or ConfigManagerErrorCode=22) in our condition. This way we get enabled (connected and disconnected adapters). Problem with all of the above properties is that none of them filter out the virtual adapters installed by virtualization software like VMware and VirtualBox. The last property to give hope is PNPDeviceID. There's an interesting observation about physical and virtual adapters with this property. Every virtual adapter PNPDeviceID starts with "ROOT\". Even VMware and VirtualBox ones. There were some really, really old physical adapters that had PNPDeviceID starting with "ROOT\" but those were in pre win XP era AFAIK. Since my minimum system to check was Windows XP SP2 I didn't have to worry about those. The only virtual adapter I've seen to not have PNPDeviceID start with "ROOT\" is the RAS Async Adapter for Wide Area Network. But because it is made by Microsoft we've eliminated it with the first condition for the manufacturer. Using the PNPDeviceID has so far proven to be really effective and I've tested it on over 20 different computers of various configurations from Windows XP laptops with wireless and bluetooth cards to virtualized Windows 2008 R2 servers. So far it always worked as expected. I will appreciate you letting me know if you find a configuration where it doesn't work. Let's see some C# code how to do this: ManagementObjectSearcher mos = null;// WHERE Manufacturer!='Microsoft' removes all of the // Microsoft provided virtual adapters like tunneling, miniports, and Wide Area Network adapters.mos = new ManagementObjectSearcher(@"SELECT * FROM Win32_NetworkAdapter WHERE Manufacturer != 'Microsoft'");// Trying the ConfigManagerErrorCode and NetConnectionStatus variations // proved to still not be enough and it returns adapters installed by // the virtualization software like VMWare and VirtualBox// ConfigManagerErrorCode = 0 -> Device is working properly. This covers enabled and/or disconnected devices// ConfigManagerErrorCode = 22 AND NetConnectionStatus = 0 -> Device is disabled and Disconnected. // Some virtual devices report ConfigManagerErrorCode = 22 (disabled) and some other NetConnectionStatus than 0mos = new ManagementObjectSearcher(@"SELECT * FROM Win32_NetworkAdapter WHERE Manufacturer != 'Microsoft' AND (ConfigManagerErrorCode = 0 OR (ConfigManagerErrorCode = 22 AND NetConnectionStatus = 0))");// Final solution with filtering on the Manufacturer and PNPDeviceID not starting with "ROOT\"// Physical devices have PNPDeviceID starting with "PCI\" or something else besides "ROOT\"mos = new ManagementObjectSearcher(@"SELECT * FROM Win32_NetworkAdapter WHERE Manufacturer != 'Microsoft' AND NOT PNPDeviceID LIKE 'ROOT\\%'");// Get the physical adapters and sort them by their index. // This is needed because they're not sorted by defaultIList<ManagementObject> managementObjectList = mos.Get() .Cast<ManagementObject>() .OrderBy(p => Convert.ToUInt32(p.Properties["Index"].Value)) .ToList();// Let's just show all the properties for all physical adapters.foreach (ManagementObject mo in managementObjectList){ foreach (PropertyData pd in mo.Properties) Console.WriteLine(pd.Name + ": " + (pd.Value ?? "N/A"));}   That's it. Hope this helps you in some way.

    Read the article

  • Swap is not copied back into physical memory

    - by GradGuy
    I have a question regarding swap and physical memory. Often times I run a program that requires a lot of memory and as a result I can see some of the data is copied from the physical memory into swap. However, once the program is terminated, and the physical memory is freed I can still see a considerable amount of data on swap which significantly slows down the system and is annoying! What is the reason behind this and how does the OS decide which part of data should go to swap? How long is this data supposed to be there and how is it "freed"?

    Read the article

  • How to verify that a physical volume is encrypted? (Ubuntu 10.04 w/ LUKS)

    - by Bob B.
    I am very new to LUKS. During installation, I tried to set up an encrypted physical volume so that everything underneath it would be encrypted. I chose "Use as: physical volume for encryption," the installation completed and I have a working environment. How can I verify that the PV is indeed encrypted? I was never prompted to provide a passphrase, so I most likely missed a step somewhere. At the end of the day, I'd like whole disk encryption if that's possible, so I don't have to worry about which parts of the file system are encrypted and which aren't. If I did miss something, do I have to start over and try again, or can it be done (relatively easily?) after the fact? I would prefer not to introduce more complexity by using TrueCrypt, etc. Environment details: The drives are md raid1. One volume group. A standard boot lv. An encrypted swap lv using a random key (which seems to be working fine). Thank you in advance for your help. This is very much a learn-as-I-go experience.

    Read the article

  • SQL SERVER – Generate Report for Index Physical Statistics – SSMS

    - by pinaldave
    Few days ago, I wrote about SQL SERVER – Out of the Box – Activity and Performance Reports from SSSMS (Link). A user asked me a question regarding if we can use similar reports to get the detail about Indexes. Yes, it is possible to do the same. There are similar type of reports are available at Database level, just like those available at the Server Instance level. You can right click on Database name and click Reports. Under Standard Reports, you will find following reports. Disk Usage Disk Usage by Top Tables Disk Usage by Table Disk Usage by Partition Backup and Restore Events All Transactions All Blocking Transactions Top Transactions by Age Top Transactions by Blocked Transactions Count Top Transactions by Locks Count Resource Locking Statistics by Objects Object Execute Statistics Database Consistency history Index Usage Statistics Index Physical Statistics Schema Change history User Statistics Select the Reports with name Index Physical Statistics. Once click, a report containing all the index names along with other information related to index will be visible, e.g. Index Type and number of partitions. One column that caught my interest was Operation Recommended. In some place, it suggested that index needs to be rebuilt. It is also possible to click and expand the column of partitions and see additional details about index as well. DBA and Developers who just want to have idea about how your index is and its physical statistics can use this tool. Click to Enlarge Note: Please note that I will rebuild my indexes just because this report is recommending it. There are many other parameters you need to consider before rebuilding indexes. However, this tool gives you the accurate stats of your index and it can be right away exported to Excel or PDF writing by clicking on the report. Reference : Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Index, SQL Optimization, SQL Performance, SQL Query, SQL Server, SQL Server Management Studio, SQL Tips and Tricks, SQL Utility, T SQL, Technology

    Read the article

  • Windows Physical Direct Memory Mapping

    - by chrisjleaf
    I'm a bit disappointed there is almost no discussion of this no matter where I look so I guess I'll have to ask. I'm writing a cross platform memory bench marking application which requires direct physical address mapping rather than virtual addressing. EDIT The solution would look something like the Linux/Unix system calls: int fd = open("/dev/mem", O_RDONLY); mmap(NULL, len, PROT_READ, MAP_SHARED, fd, PHYSICAL_ADDRESS_OFFSET); which will require the kernel to either give you a virtual page mapping to the desired physical address or return that it failed. This does require supervisor privileges but that is ok. I have seen a lot of information about shared memory and memory mapped files but all of these reside on disc and are thus not really useful when I'm trying to make a system dependent read. It is very similar to writing an IO driver although I do no need write permissions to the physical address. This site gives an example of how to do it on a driver level using the Windows Driver Kit: NT Insider: Sharing Memory between drivers and applications This solution would probably require Visual Studio which currently I do not have access to. (I have downloaded the WDK api but it complained about my use of GCC for Windows). I'm traditionally a Linux programmer so I'm hoping there might be something really simple I'm missing. Thanks in advance if you know something I don't!

    Read the article

  • Need some help understanding IO Statistics

    - by Abe Miessler
    I have a query that has a very costly INDEX SEEK operation in the execution plan. In order to track down the cause i set IO STATISTICS on and ran it. In the problem section it gave the following statistics: Table '#TempStudents_Enrollment2_____________________________________000000004D5F'. Scan count 0, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table 'Worktable'. Scan count 0, logical reads 0, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#TempRace2______________________________________________000000004D58'. Scan count 1, logical reads 1, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table 'Worktable'. Scan count 0, logical reads 0, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table 'RefRace'. Scan count 120, logical reads 240, physical reads 1, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table 'RefFedEnctyRaceCatg'. Scan count 18, logical reads 36, physical reads 2, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#43B0BA0F'. Scan count 1, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#42BC95D6'. Scan count 1, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#41C8719D'. Scan count 1, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#40D44D64'. Scan count 1, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#LEA2_________________________________________________000000004D56'. Scan count 1, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#39332B9C'. Scan count 1, logical reads 60, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#School2________________________________________________000000004D57'. Scan count 1, logical reads 29164, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#GenderKey______________________________________________000000004D5A'. Scan count 1, logical reads 29164, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#LangAcqKey_____________________________________________000000004D5B'. Scan count 1, logical reads 29164, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#TransferCatKey___________________________________________000000004D5C'. Scan count 1, logical reads 29164, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#ResCatKey______________________________________________000000004D5D'. Scan count 1, logical reads 29164, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table 'RPT_SnapShot_1_4_StuPgm_Denorm'. Scan count 2344954, logical reads 4992518, physical reads 16, read-ahead reads 8, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#3FE0292B'. Scan count 1, logical reads 2344954, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table 'RPT_SnapShot_1_4_StuEnrlmt_Denorm'. Scan count 20, logical reads 87679, physical reads 0, read-ahead reads 87425, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table '#GradeKey_______________________________________________000000004D59'. Scan count 1, logical reads 1, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. What should I look for in here when i'm looking to improve the performance? The line with over 2 million for the Scan count looked suspicious to me but I really don't know. Does anyone see anything here that i should look into in more detail?

    Read the article

  • Automated “ubuntu-12.04.1-server-amd64” OS installation on physical machine

    - by user285336
    We are using Physical server and are in process of Automated “ubuntu-12.04.1-server-amd64” OS installation on it. There are two HDD for OS installation purpose and there are RAID1 relation between them. This setup has been done through BIOS. The kickstart configuration file looks like this: #Generated by Kickstart Configurator #platform=AMD64 or Intel EM64T #System language lang en_US #Language modules to install langsupport en_US #System keyboard keyboard us #System mouse mouse #System timezone timezone Asia/Dili #Root password rootpw --iscrypted $1$Yl1QJyta$KzIT.kq3i9E5XaiQKcUJn/ #Initial user user ankit --fullname "Ankit" --iscrypted --password $1$c6Yflpea$pi1QQ59/jgywmGwBv25z3/ #Reboot after installation reboot #Use text mode install text #Install OS instead of upgrade install #Use Web installation url --url my_repo_location #System bootloader configuration bootloader --location=mbr #Clear the Master Boot Record zerombr yes #Partition clearing information clearpart --all --initlabel #Disk partitioning information part /boot --fstype ext4 --size 100 --ondisk sda part / --fstype ext4 --size 10000 --ondisk sda part /var --fstype ext4 --size 10000 --ondisk sda part swap --size 1024 --ondisk sdb #System authorization infomation auth --useshadow --enablemd5 #Network information network --bootproto=dhcp --device=eth0 #Firewall configuration firewall --enabled --trust=eth0 --http --ftp --ssh --telnet --smtp #X Window System configuration information xconfig --depth=8 --resolution=640x480 --defaultdesktop=GNOME But I am getting the below error : No root file system is defined Please suggest on this. Do we need to do any modification in kickstart configuration file. Any help in this regard will be very helpful for us. The automated Ubuntu OS installation is successful in Virtual Machine(VM) with the above ks.cfg (kickstart configuration file ) but failing in case of physical machine. Please suggest on this and if possible provide the new ks.cfg file to resolve above problem. Thanks & Regards, Rajesh Prasad

    Read the article

  • Minimum percentage of free physical memory that Linux require for optimal performance

    - by csoto
    Recently, we have been getting questions about this percentage of free physical memory that OS require for optimal performance, mainly applicable to physical compute nodes. Under normal conditions you may see that at the nodes without any application running the OS take (for example) between 24 and 25 GB of memory. The Linux system reports the free memory in a different way, and most of those 25gbs (of the example) are available for user processes. IE: Mem: 99191652k total, 23785732k used, 75405920k free, 173320k buffers The MOS Doc Id. 233753.1 - "Analyzing Data Provided by '/proc/meminfo'" - explains it (section 4 - "Final Remarks"): Free Memory and Used Memory Estimating the resource usage, especially the memory consumption of processes is by far more complicated than it looks like at a first glance. The philosophy is an unused resource is a wasted resource.The kernel therefore will use as much RAM as it can to cache information from your local and remote filesystems/disks. This builds up over time as reads and writes are done on the system trying to keep the data stored in RAM as relevant as possible to the processes that have been running on your system. If there is free RAM available, more caching will be performed and thus more memory 'consumed'. However this doesn't really count as resource usage, since this cached memory is available in case some other process needs it. The cache is reclaimed, not at the time of process exit (you might start up another process soon that needs the same data), but upon demand. That said, focusing more specifically on the percentage question, apart from this memory that OS takes, how much should be the minimum free memory that must be available every node so that they operate normally? The answer is: As a rule of thumb 80% memory utilization is a good threshold, anything bigger than that should be investigated and remedied.

    Read the article

  • Unable to open the physical file - Access is denied

    - by rachitp
    I’m an using Admin account on Windows 7 and try to attach umbraco database to my local SQL 2008 R2 instance. I’m getting the following error: Unable to open the physical file "D:\Tech\umbraco\build\App_Data\umbraco.mdf". Operating system error 5: "5(Access is denied.)". (Microsoft SQL Server, Error: 5120) What the heck? I tried to brainstorm what the issue is and found out that I didn’t open my SSMS with “Run As Administrator” (although I’m using Admin account in Win7 and the...(read more)

    Read the article

  • If Computer Problems were Physical Life Events [Video]

    - by Asian Angel
    Things can be bad (and frustrating) enough when you have problems with your computer, but what if those events actually crossed over into physical reality? Note: Video contains some language that may be considered inappropriate. If Computer Problems Were Real – Awkward Spaceship [via Fail Desk] How To Properly Scan a Photograph (And Get An Even Better Image) The HTG Guide to Hiding Your Data in a TrueCrypt Hidden Volume Make Your Own Windows 8 Start Button with Zero Memory Usage

    Read the article

  • Game-over! Gaining Physical access to a computer

    Security requires defense in depth. The cleverest intrusion detection system, combined with the best antivirus, won’t help you if a malicious person can gain physical access to your PC or server. A routine job, helping a family member remove a malware infection, brings it home to Wesley just how easy it is to get a command prompt with SYSTEM access on any PC, and inspires him to give a warning about the consequences.

    Read the article

  • Wear and tear on server hard drive from filesystem polling by PHP script

    - by jackie
    So I'm working on a discussion platform, and various clients will visit http://host/thread.php, which will render the discussion thread to date in addition to a form to submit a new post. When a new post is submitted, I would like all of the other clients with browser windows open to have it appear in near-real-time. One of the constraints of my script is that it may not use a DBMS and it must stay in the filesystem. Additionally, I can't use any PECL/PEAR extensions like inotify or anything like that for IPC. The flow will look like this: Client A requests thread.php and the thread is so far empty, but nonetheless it opens a Server-Side Event at eventPusher.php. Client B does the same. Client A fills out a post in the form and and submits (POSTs) it to subHandler.php. ??? (subHandler stores the new submission into the main thread storefile which gets read from when a fresh, new client requests thread.php, in addition to somehow signalling to the continually-running eventPusher event-source that a new comment was posted and that it should echo the event-json to the client. How, exactly, it will send this signal I'm yet unsure of, but there are a few options that I've thought of -- this is the crux of the question, so see below for more clarification) eventPusher.php happily pushes the new event to the client and it shows up soon after it was originally submitted on all clients who have the page open's screens. Now for the #4 missing-link mystery-step, I see a few problems. I mean, either way, eventPusher is gonna be doing a while loop of some sort -- it's gonna be polling something, I think that much is clear. (If that's a bad assumption please do let me know.) Now, the simplest way would be subHandler gets invoked on the form submission, writes it to the main store in addition to newComments.xml, then exits without doing anything else. Then eventPusher checks in newComments.xml every X seconds (by the way, what would be a reasonable time interval here?) and if it finds something then it emits an event to the client. Now, my fear with this is that the server's hard drive will have to constantly start spinning up. Maybe this isn't the case, perhaps it would just get cached in RAM and the linux kernel would take care of this transparently such that filesystem access doesn't actually engage the device because the kernel knows that that particular file hasn't changed since last read. * idea #2: I have no idea how to go about this, but perhaps there is a variable scope that gets stored in general RAM on the system which can be read by any process. Like if we mega-exported a bash variable so that $new_post is normally false but it gets toggled to true by subHandler, and then back to flase once it's pushed to the client. I doubt there's such a variable scope in PHP directly, but I struggle with the concept of variable scope, I just can't seem to understand it no matter what I read on it. * idea #3: eventPusher queries ps in its whileloop for another instance of itself. If there's not another eventPusher active then it's highly unlikely that new comments will be getting submitted. It's okay if this only works =90% of the time, it doesn't need to be completely foolproof. * idea #4: eventPusher queries DMESG to see if that file's been written to recently. So to sum everything up, I need to have inter-php-script-communication in near-real-time that will work on a standard mod_php shared hosting setup without any elevated privileges, PHP addon modules, or other system adjustments that can't be done from the PHP script itself at runtime. With*out* spinning up the drive more than a few times. No SQL servers either. Apologies if my english isn't the best, I'm still trying to improve on it.

    Read the article

  • Design Book–Fourth(last) Section (Physical Abstraction Optimization)

    - by drsql
    In this last section of the book, we will shift focus to the physical abstraction layer optimization. By this I mean the little bits and pieces of the design that is specifically there for performance and are actually part of the relational engine (read: the part of the SQL Server experience that ideally is hidden from you completely, but in 2010 reality it isn’t quite so yet.  This includes all of the data structures like database, files, etc; the optimizer; some coding, etc. In my mind, this...(read more)

    Read the article

  • Transfer a ssh session between the same physical devices from one network to another

    - by Vivek V K
    My server has 2 IP addresses via two networks. Due to some restrictions,my client will be able to access only one of the network at a time. Hence, I want a way to transfer a live ssh session with all the open applications seamlessly from one network to another. The physical devices (client and the server) are the same. What changes is the network through which it connects. can this be done? Thanks!

    Read the article

  • Add physical disk to KVM virtual machine

    - by evan
    I'm setting up a file server (nas4free) as a KVM virtual machine on a Ubuntu Server 12.04 system. How do I add physical hard drives directly to the VM so they can be used by the guest (nas4free), but not the host? Specifically the hard drive I'd like to mount is /dev/sda (which is not currently mounted on the server.) So far I've found two solutions but I haven't gotten either to work. The first is from Server Fault where it's suggested to use virt-manager. I haven't gotent this to work because when I try to select an existing drive nothing is being listed. My best guess as to why this is, is because I'm using virt-manager over ssh and not connecting as root, should that make a difference? The second solution I've found here is to just run the command (modified for my system) qm set nas4free -virtio /dev/sda but that seems to require proxmox which I don't have installed and doesn't seem to be in the default repositories? Finally, once the above is sorted out and I can mount the drive directly to the VM, does anyone have an experience with whether the drive should be mounted to the VM as scsi, ide, or virtio? (I know virtio was recommend in the linked ServerFault page, but I hadn't heard of it before now since I mainly use VMWare). Thanks for your help!!!

    Read the article

  • Subscription based eCommerce Site selling Physical Goods

    - by Kash
    I want to implement a system where customers can buy physical products as subscription with recurring billing. Customers will come to my site, visit product page and buy stuff. They need to register an account before purchasing. After registration they will be forwarded to payment processor for payment and after successful payment they will be returned back to my site. Requirement: I dont want to use Paypal as a payment processor. It will be recurring payment on monthly, quarterly, bi-annual or annual basis. Customers can login to my site in order to view their Order History, Profile Management and can edit their Billing and/or Shipping details. Customers can cancel their Subscription any time after login to their account on my site. Plan: Currently I am using wordpress with WooCommerce plugin for eCommerce functionality. I am planning to use Amazon as a payment processor. I have searched WooCommerce Extension Drectory and found WC Subscription extension that can be used for my site. But I just confirmed from the Support WC Subscription only support recurring payment with Paypal and Stripe, no other payment processor is supported at the moment. Questions: According to my need, what will be the best solution? I am open to switch the platform from Wordpress to something else that can fulfill my requirement.

    Read the article

  • Multiple Businesses at The Same Physical Address - SEO / Google Places

    - by Howdy_McGee
    I was wondering what kind if there would be any negative effects to have multiple businesses having the exact same physical address on their website. Currently we have five businesses at the exact same address and it shows on their website, so when people google one of the five businesses address their going to get multiple results from multiple website most of which will not be what their looking for. What is a way around this / what can I do about this? Would adding "Suite Numbers" be a solution? A thought occurred that it might be a good idea to create a landing page for users that are looking up a business by it's address via google. The page will bring up multiple businesses since we have a few at the same address but if we have a landing page at the top which then leads to multiple businesses that might solve the multiple address seo problem. Going to keep researching it though. I also know for Google Places (possible bing local and yahoo local) this could also become a problem. I've submitted an inquiry with them but I wanted to know if anybody had a ready-made solution around this so that Google doesn't bunch all these companies together into one. Thanks!

    Read the article

  • Layers - Logical seperation vs physical

    - by P.Brian.Mackey
    Some programmers recommend logical seperation of layers over physical. For example, given a DL, this means we create a DL namespace not a DL assembly. Benefits include: faster compilation time simpler deployment Faster startup time for your program Less assemblies to reference Im on a small team of 5 devs. We have over 50 assemblies to maintain. IMO this ratio is far from ideal. I prefer an extreme programming approach. Where if 100 assemblies are easier to maintain than 10,000...then 1 assembly must be easier than 100. Given technical limits, we should strive for < 5 assemblies. New assemblies are created out of technical need not layer requirements. Developers are worried for a few reasons. A. People like to work in their own environment so they dont step on eachothers toes. B. Microsoft tends to create new assemblies. E.G. Asp.net has its own DLL, so does winforms. Etc. C. Devs view this drive for a common assembly as a threat. Some team members Have a tendency to change the common layer without regard for how it will impact dependencies. My personal view: I view A. as silos, aka cowboy programming and suggest we implement branching to create isolation. C. First, that is a human problem and we shouldnt create technical work arounds for human behavior. Second, my goal is not to put everything in common. Rather, I want partitions to be made in namespaces not assemblies. Having a shared assembly doesnt make everything common. I want the community to chime in and tell me if Ive gone off my rocker. Is a drive for a single assembly or my viewpoint illogical or otherwise a bad idea?

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >