Search Results

Search found 41 results on 2 pages for 'regasm'.

Page 2/2 | < Previous Page | 1 2 

  • Exposing.NET assembly as COM 101

    - by Jan Zich
    I have trouble to expose a .NET assembly in COM. It seems that I must be missing some basic step because I think I followed all tutorials and documentation I found as well as common sense, but still when I do (in a test VBScript): Set o = CreateObject("MyLib.MyClass") It keeps saying that the object cannot be created. Here are the steps I have done: I have simple one method dummy class with no attributes. The class is in a class library which has "Make assembly COM-visible" ticked in Visual Studio. The class library is signed. The DLL is registered via RegAsm.exe with the /codebase parameter (I don’t want / cannot add the DLL to GAC). Just to be sure, I tried to copy the library to the same directory as the test VBScript, but it does not help. Edit: I should have mentioned that the I can instantiate the class in COM if I put the DLL into GAC.

    Read the article

  • Advantage Extended Procedure - Create and install

    - by Garcia Julien
    Hi, i try to create an AEP for my advantage Database. I create a AEP project on VS2008 and i,ve got the dll. I copy de .dll to the folder where is my datadictionnary. I tried to register my dll with regasm but i've always got the warning to give strong name, but i tried a lot of thing and i got this error again. So i tried to install the AEP but i haven't the ProgId required. Someone can help me to create and install an AEP? Thanks Julien

    Read the article

  • Working with .tlb files

    - by aF
    Hello, I've created a c# com interop dll project that generates both .dll and .tlb files. When I use them on the computer that I built everythig, all works fine. But when I pass it to another computer (with the same windows installed), it doesn't work. I allready made the: Regasm.exe SoundLogDLL.dll /tlb:SoundLogDLL.tlb command, but still doesn't work. I also done the work in all computers in vs2008 before releasing it! Is there anything else that I have to do?

    Read the article

  • Do I need to force the GAC to reload an assembly? Is this possible?

    - by Ben McCormack
    I've added types to my .NET classes that I'm using for COM interop. To get it to work with my VB6 application, I unregistered the DLL and re-registered it (using regasm). I then uninstalled and reinstalled it to the GAC (using gacutil). The types are showing up in the VB6 object explorer, but when I run the application in the VB6 IDE, it breaks on the line that instantiates the new types with the error: Automation Errror - The System cannot find the file specified. I thought this odd since I had already updated the GAC, so I uninstalled the dll from the GAC and got the exact same error, which seems to indicate that the older version of the dll is already in memory and needs to be "reloaded" so that the newer DLL is in memory. Is this possible, and if so, what do I need to do?

    Read the article

  • C# COM+ component isn't getting the constructor string

    - by Kyle W
    I've created a COM+ component in C# with a strong name, COM Visible, ProgId, etc... I've then registered the assembly with regasm, and imported it into the COM+ Applications in Component Services. It runs just fine, and loads up the DLL, except that the constructor string that is passed in is always empty. The method signature is protected override void Construct(string constructString), and it is being called before the method on the actual component. In the component details in COM+ Applications, the constructor string is checked and a value is entered. Any help is appreciated.

    Read the article

  • how can i access C# dll from VBScript on client machine

    - by maraheem
    i have created a C# dll file on my machine as shown below: namespace myDLL { public class myClass { public string myFunction() { return "I am Here"; } } } then i created a tlb file with "tlbexp" command, then i used the "regasm" command n registered this dll on my machine. When i created an object of type myClass on my machine using VBScript, everything is working fine... here i used the CreateObject() method as shown below: Set myObj = CreateObject("myDll.myClass") Now i want to create an object of type myClass from VBScript that is running on another machine, how can i do this. please help me how can i access that dll file, am using the CreateObject() function as shown below: Set HD = CreateObject("myDll.myClass","myMachineName") now am getting error as "permission denied"

    Read the article

  • fatal error C1084: Cannot read type library file: 'Smegui.tlb': Error loading type library/DLL.

    - by Steiny
    Hi, I am trying to build an old version of an application which consists of VC++ projects that were written in Visual Studio 2003. My OS is Windows 7 Enterprise (64-bit). When I try and build the solution I get the following errors: error C4772: #import referenced a type from a missing type library; '__missing_type__' used as a placeholder fatal error C1084: Cannot read type library file: 'Smegui.tlb': Error loading type library/DLL. They both complain about the following import statement: #import "Smegui.tlb" no_implementation This is not a case of the file path being incorrect as renaming the Smegui.tlb file causes the compiler to throw another error saying it cannot find the library. Smegui is from another application that this one depends on. I thought perhaps I was missing a dll but there is no such thing as Smegui.dll. All I know about .tlb files is that they are a type library and you can create them from an assembly using tlbexp.exe or regasm.exe (the later also registers the assembly with COM) There is also an Apache Ant build script which uses a custom task to invoke devenv.com to build the projects. This is the same script that the build server originally used to build the application. It gives me the same errors when I try and run it. The strangest thing about this is that I knew it ought to work seeing as it is all freshly checked out from subversion. I tried many different combinations of admin vs user elevation, VS vs Ant build, cleaning, release. I have got it to build successfully about 5 times but the build seems to be non-deterministic. If anyone can shed some light on how this tlb stuff even works or what this error might mean I would greatly appreciate it. Cheers, Steiny

    Read the article

  • Referencing .NET Assembly in VB6 won't work

    - by dretzlaff17
    I wrote a .net assembly using c# to perform functions that will be used by both managed and unmanaged code. I have a VB6 project that now needs to use the assembly via COM. I created my .net assembly, made sure that ComVisible is set to true and that it is registered for COM interop via project properties. public class MyClass [ComVisible(true)] public string GetResponse() { return "Testing Response" } } I build the assembly and copied the file into a folder. TestInterop.dll I then run a batch file to register the assembly tool to register the object for COM. cd C:\Windows\Microsoft.NET\Framework\v4.0.30319\ regasm "c:\Program Files\TestApp\TestInterop.dll" /tlb:TestInterop.tlb I open a new VB6 application and reference TestInterop.dll In VB6 I write the following code and it compiles. Dim obj as TestInterop.MyClass Set obj = new TestInterop.MyClass Dim strTest as string strTest = obj.GetRespose() When I run the program it errors on the obj.GetResponse() line. Run-time error' -2147024894 (80070002'): Automation error The system cannot find the file specified Also, the intellesense does not work on obj. I had to type the GetResponse method. Is this normal? Does anyone have any clue what could be wrong or what steps I missed. Thanks!

    Read the article

  • C# COM objects with VB6/asp error

    - by Ken
    I'm trying to expose a C# class library via COM so that I can use it in a classic asp web site. I've used sn - k, regasm and gacutil. About all I can do now though is echo back strings. Methods which take Class variables as input are not working for me. ie my test method EchoPerson(Person p) which returns a string of the first and last name doesn't work. I get a runtime error 5 - Invalid procedure call or argument. Please let me know what I am missing. Also I have no intellisence in VB. What do I need to do to get the intellisence working. Below is my C# test code namespace MrdcToFastCom { public class Person : MrdcToFastCom.IPerson { public string FirstName { get; set; } public string LastName { get; set; } } public class ComTester : MrdcToFastCom.IComTester { public string EchoString(string s) { return ("Echo: " + s); } public string Hello() { return "Hello"; } public string EchoPerson(ref Person p) { return string.Format("{0} {1}", p.FirstName, p.LastName); } } } and VB6 call Private Sub btnClickMe_Click() Dim ct Set ct = New MrdcToFastCom.ComTester Dim p Set p = New MrdcToFastCom.Person p.FirstName = "Joe" p.LastName = "Test" Dim s s = ct.EchoPerson(p) 'Error on this line tbx1.Text = s End Sub

    Read the article

  • Inconsistency in passing objects from VBA to .NET via COM

    - by Akash
    I have the following interface defined to expose a .NET class to COM: [InterfaceType(ComInterfaceType.InterfaceIsDual)] [Guid("6A983BCC-5C83-4b30-8400-690763939659")] [ComVisible(true)] public interface IComClass { object Value { get; set; } object GetValue(); void SetValue(object value); } The implementation of this interface is trivial: [ClassInterface(ClassInterfaceType.None)] [Guid("66D0490F-718A-4722-8425-606A6C999B82")] [ComVisible(true)] public class ComClass : IComClass { private object _value = 123.456; public object Value { get { return this._value; } set { this._value = value; } } public object GetValue() { return this._value; } public void SetValue(object value) { this._value = value; } } I have then registered this using RegAsm, and tried to call it from Excel via the following code: Public Sub ComInterop() Dim cc As ComClass Set cc = New ComClass cc.SetValue (555.555) valueByGetter = cc.GetValue valueByProperty = cc.Value cc.Value = 555.555 End Sub When I step throught this code, valueByGetter = 555.5555 and valueByProperty = 555.555 as expected. However, I get an "Object required" runtime error on the final line. Why does setting the value via the setter method work but setting via the property fail? What do I have to change to get the property to work as expected?

    Read the article

  • Hot to make COM ActiveX object work in IE 64 bit?

    - by Kurtevich
    Hi! I have a COM object embeded in ASP.NET page using <object classid="clsid:XXX...">. It works in IE 32 bit, but does not work in IE 64 bit - can't access its functions. There are no error messages, no event logs where I can get some information. The dll is in C#, includes COM visible class, compiled for Any CPU (though I also tried x86), and registered during client installation by executing regasm. This creates registry keys, well everything works fine except for IE 64. I searched internet about the issue or at least some guidlines and didn't find anything. I received an answer on another forum, something about _MERGE_PROXYSTUB (I guess it's preprocessor definition?) and ProxyStubClsid32 registry key, but not very detailed. Well, I searched again, didn't find much, and experimented: rebuilt with _MERGE_PROXYSTUB defined, created ProxyStubClsid32 keys everywhere, but with no result. What can be at least possible solutions or points to look at? Maybe there is a way at least to get the logs about why IE 64 can't access it?

    Read the article

  • Exposing a .Net Service

    - by Dave
    I have written a Windows Service in .Net and I want to expose the classes to be called by other .Net code. Specifically, I have an API that I want to expose via a DLL that will be placed in the GAC, and I want the DLL in the GAC to use the classes of the .Net Windows Service. I need this architecture as the code in the Windows Service needs to be run as a different user/account as the caller of the API (the account would be created at install time). My plan was to expose the Windows Service classes via COM (regasm.exe to register and tlbexp.exe to create the type library), and then call the classes in the GAC DLL via COM (imported via tlbimp.exe). However I get the following error from tlbimp: TlbImp : error TI0000 : System.Runtime.InteropServices.COMException - Type library '' was exported from a CLR assembly and cannot be re- imported as a CLR assembly. This implies to me that my method is not going to easily work. I can only think that I might need a C++ DLL as a bridge for my GAC DLL to invoke the COM calls, but this seems like a nasty solution. I am basically looking for suggestions. Does anyone know how to expose classes of a Windows Service written in .Net to other .Net code?

    Read the article

  • How can I invoke a .Net DLL from a LabView 6.1 VI?

    - by tw1k
    I work in a manufacturing company that uses LabView for testing the devices we make. Most of the test engineers are using 7.1 which can natively reference a .Net assembly. However, there is a group that is stuck on LabView 6.1. I would like for them to be able to use my .Net assembly which is basically a proxy to some web services. I have created a test assembly that is nothing more than Hello World, and I'm trying to consume it in a VI. I made it COM visible, and registered it with regasm.exe and created a type library, which I'm not sure I need. I can see it in Visual Studio in the list of COM objects when I open the Add Reference window, so I know it's registered properly. I'm very unfamiliar with VI's. I'm only looking at it because no one I have spoken to in manufacturing knows anything about invoking a COM object in a VI. I'm basically looking for some names of controls or menu options to get the test engineers pointed in the right direction. I did a bunch of web searching on Google and the NI forums, but didn't find much. Alternatively, would it be easier to write a C or C++ DLL that acts as a proxy to my .Net DLL? Or is there a simple way to invoke a web service from a VI? That might obviate the need for a DLL altogether. I'm currently reading through this document from NI for help, but it obviously knows nothing about .Net and might not be able to help me choose the best path forward.

    Read the article

  • Server.CreateObject Fails when calling .Net object from ASP on 64-bit windows in IIS 32-bit mode

    - by DrFredEdison
    I have a server running Windows 2003 64-bit, that runs IIS in 32-bit mode. I have a COM object that was registered using the following command: C:\WINDOWS\microsoft.net\Framework\v2.0.50727>regasm D:\Path\To\MyDll.dll /tlb:MyTLB.tlb /codebase When I create the object via ASP I get: Server object error 'ASP 0177 : 8000ffff' Server.CreateObject Failed /includes/a_URLFilter.asp, line 19 8000ffff When I create the object in a vbs script and use the 32-bit version of cscript (in \Windows\syswow64) it works fine. I've checked permissions on the DLL, and the IUSR has Read/Execute. Even if I add the IUSR to the Administrators group, I get the same error. This is the log from ProcessMonitor filtering for the path of my dll (annotated with my actions): [Stop IIS] 1:56:30.0891918 PM w3wp.exe 4088 CloseFile D:\Path\To\MyDll.dll SUCCESS [Start IIS] [Refresh ASP page that uses DLL] 1:56:42.7825154 PM w3wp.exe 2196 QueryOpen D:\Path\To\MyDll.dll SUCCESS CreationTime: 8/19/2009 1:11:17 PM, LastAccessTime: 8/19/2009 1:30:26 PM, LastWriteTime: 8/18/2009 12:09:33 PM, ChangeTime: 8/19/2009 1:22:02 PM, AllocationSize: 20,480, EndOfFile: 20,480, FileAttributes: A 1:56:42.7825972 PM w3wp.exe 2196 QueryOpen D:\Path\To\MyDll.dll SUCCESS CreationTime: 8/19/2009 1:11:17 PM, LastAccessTime: 8/19/2009 1:30:26 PM, LastWriteTime: 8/18/2009 12:09:33 PM, ChangeTime: 8/19/2009 1:22:02 PM, AllocationSize: 20,480, EndOfFile: 20,480, FileAttributes: A 1:56:42.7826961 PM w3wp.exe 2196 CreateFile D:\Path\To\MyDll.dll SUCCESS Desired Access: Generic Read, Disposition: Open, Options: Synchronous IO Non-Alert, Non-Directory File, Attributes: N, ShareMode: Read, Delete, AllocationSize: n/a, Impersonating: SERVER2\IUSR_SERVER2, OpenResult: Opened 1:56:42.7827194 PM w3wp.exe 2196 CreateFileMapping D:\Path\To\MyDll.dll SUCCESS SyncType: SyncTypeCreateSection, PageProtection: 1:56:42.7827546 PM w3wp.exe 2196 CreateFileMapping D:\Path\To\MyDll.dll SUCCESS SyncType: SyncTypeOther 1:56:42.7829130 PM w3wp.exe 2196 Load Image D:\Path\To\MyDll.dll SUCCESS Image Base: 0x6350000, Image Size: 0x8000 1:56:42.7830590 PM w3wp.exe 2196 Load Image D:\Path\To\MyDll.dll SUCCESS Image Base: 0x6360000, Image Size: 0x8000 1:56:42.7838855 PM w3wp.exe 2196 CreateFile D:\Webspace\SecurityDll\bin SUCCESS Desired Access: Read Data/List Directory, Synchronize, Disposition: Open, Options: Directory, Synchronous IO Non-Alert, Attributes: n/a, ShareMode: Read, Write, Delete, AllocationSize: n/a, Impersonating: SERVER2\IUSR_SERVER2, OpenResult: Opened 1:56:42.7839081 PM w3wp.exe 2196 QueryDirectory D:\Path\To\MyDll.INI NO SUCH FILE Filter: SecurityDll.INI 1:56:42.7839281 PM w3wp.exe 2196 CloseFile D:\Webspace\SecurityDll\bin SUCCESS [Refresh ASP page that uses DLL] [Refresh ASP page that uses DLL] [Refresh ASP page that uses DLL] This dll works fine on other servers, running 32-bit windows. I can't think of anything else that would make this work. Any suggestions? UPDATE The .dll is not in the GAC, it is compiled as 32-bit, and is Strongly signed.

    Read the article

  • How do I properly register the Type Library of A VB.NET COM+ Component?

    - by k_Dank
    I am looking to upgrade legacy VB6 COM+ components to VB.NET components. I have seemingly upgraded one already, called EventPackage, which has one class, IEventListener. Another, TradeOrders, Implements EventPackage.IEventListener. When attempting to build TradeOrders, I get the following Errors/Warnings; Cannot load type library for reference "EventPackage". Library not registered. (Exception from HRESULT: 0x8002801D (TYPE_E_LIBNOTREGISTERED)) The referenced component 'EventPackage' could not be found. Type 'EventPackage.IEventListener' is not defined. In the .vbproj, I notice this reference <COMReference Include="EventPackage"> <Guid>{0D76C094-21A6-4E04-802B-6E539F7102D7}</Guid> <Lcid>0</Lcid> <VersionMajor>2</VersionMajor> <VersionMinor>0</VersionMinor> <WrapperTool>tlbimp</WrapperTool> </COMReference> When I search the registry for this Guid, I find nothing. When using GUIDs for similar COM+ objects, I find them in HKEY_CLASSES_ROOT\CLSID\{...}\TypeLib ("..." being the GUID of the other component). When I go to the registry key name corresponding to EventPackage.IEventListener, I find that there is no \TypeLib subkey. As you might suspect, searching the reg for "0D76C094-21A6-4E04-802B-6E539F7102D7" yields no results. So I know this must be a registry problem, But I have tried seemingly every google result I have found. I have tried Regasm and regsvcs .exe's to no avail. Many pages just tell me that dragging the dll to the COM+ manager should automatically register the component. So how do I register the Type library? Details on how I made EventPackage COM+ component Ran the VB6-VB.NET wizard Then I added some lines to the assemblyinfo.vb file added Imports System.EnterpriseServices added Imports System.EnterpriseServices Imports System.Data.SqlClient <Assembly: CLSCompliant(True)> <Assembly: AssemblyKeyFileAttribute("...")> for a strong name <Assembly: Guid("...")> (Where "..." is the COM+ CLSID of the old component) I added the following to the class file IEventListener.VB Imports System.EnterpriseServices <ComClass("...")> _ (Where ... is the proper COM+ CLSID, that is the only argument) Inherits ServicedComponent changed the ID made by the Conversion wizard to the proper value (from <System.Runtime.InteropServices.ProgId("IEventListener_NET.IEventListener)> to <System.Runtime.InteropServices.ProgId("EventPackage.IEventListener")> _ Then I dragged the DLL into the COM+ manager in the proper COM+ application (although, the "Path" is not specified and only says mscoree.dll)

    Read the article

  • How to deploy a visual studio custom tool?

    - by Aen Sidhe
    Hello. I have a my own custom tool for Visual Studio 2008 SP1. It consists of 5 assemblies: 3 assemblies with code that used heavily in my other projects, 1 assembly-wrapper above VS2008 SDK and assembly with the tool. If I'd debug my tool from visual studio, using "Run external program" option with command line "C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe" and arguments "/ranu /rootsuffix Exp" all work perfectly. After that I trying to deploy it to my working VS copy, not to experimental hive doing: gacutil /i Asm1.dll for all my assemblies and doing RegAsm Asm1.dll only for assembly with custom tool. Neither of utils prints any error, all work as planned, even registry keys appeared. But my tool don't work even after PC restart. What did I do wrong? Wrapper looks like that: [ComVisible(true)] public abstract class CustomToolBase : IVsSingleFileGenerator, IObjectWithSite { #region IVsSingleFileGenerator Members int IVsSingleFileGenerator.DefaultExtension(out string pbstrDefaultExtension) { pbstrDefaultExtension = ".cs"; return 0; } int IVsSingleFileGenerator.Generate(string wszInputFilePath, string bstrInputFileContents, string wszDefaultNamespace, IntPtr[] rgbOutputFileContents, out uint pcbOutput, IVsGeneratorProgress pGenerateProgress) { GenerationEventArgs gea = new GenerationEventArgs( bstrInputFileContents, wszInputFilePath, wszDefaultNamespace, new ServiceProvider(Site as Microsoft.VisualStudio.OLE.Interop.IServiceProvider) .GetService(typeof(ProjectItem)) as ProjectItem, new GenerationProgressFacade(pGenerateProgress) ); if (OnGenerateCode != null) { OnGenerateCode(this, gea); } byte[] bytes = gea.GetOutputCodeBytes(); int outputLength = bytes.Length; rgbOutputFileContents[0] = Marshal.AllocCoTaskMem(outputLength); Marshal.Copy(bytes, 0, rgbOutputFileContents[0], outputLength); pcbOutput = (uint)outputLength; return VSConstants.S_OK; } #endregion #region IObjectWithSite Members void IObjectWithSite.GetSite(ref Guid riid, out IntPtr ppvSite) { IntPtr pUnk = Marshal.GetIUnknownForObject(Site); IntPtr intPointer = IntPtr.Zero; Marshal.QueryInterface(pUnk, ref riid, out intPointer); ppvSite = intPointer; } void IObjectWithSite.SetSite(object pUnkSite) { Site = pUnkSite; } #endregion #region Public Members public object Site { get; private set; } public event EventHandler<GenerationEventArgs> OnGenerateCode; [ComRegisterFunction] public static void Register(Type type) { using (var parent = Registry.LocalMachine.OpenSubKey(@"Software\Microsoft\VisualStudio\9.0", true)) foreach (CustomToolRegistrationAttribute ourData in type.GetCustomAttributes(typeof(CustomToolRegistrationAttribute), false)) ourData.Register(x => parent.CreateSubKey(x), (x, name, value) => x.SetValue(name, value)); } [ComUnregisterFunction] public static void Unregister(Type type) { using (var parent = Registry.LocalMachine.OpenSubKey(@"Software\Microsoft\VisualStudio\9.0", true)) foreach (CustomToolRegistrationAttribute ourData in type.GetCustomAttributes(typeof(CustomToolRegistrationAttribute), false)) ourData.Unregister(x => parent.DeleteSubKey(x, false)); } #endregion } My tool code: [ComVisible(true)] [Guid("55A6C192-D29F-4e22-84DA-DBAF314ED5C3")] [CustomToolRegistration(ToolName, typeof(TransportGeneratorTool))] [ProvideObject(typeof(TransportGeneratorTool))] public class TransportGeneratorTool : CustomToolBase { private const string ToolName = "TransportGeneratorTool"; public TransportGeneratorTool() { OnGenerateCode += GenerateCode; } private static void GenerateCode(object s, GenerationEventArgs e) { try { var serializer = new XmlSerializer(typeof (Parser.System)); using (var reader = new StringReader(e.InputText)) using (var writer = new StringWriter(e.OutputCode)) { Generator.System = (Parser.System) serializer.Deserialize(reader); Generator.System.Namespace = e.Namespace; Generator.GenerateSource(writer); } } catch (Exception ex) { e.Progress.GenerateError(ex.ToString()); } } } Resulting registry keys: Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\VisualStudio\9.0\Generators] [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\VisualStudio\9.0\Generators\{FAE04EC1-301F-11D3-BF4B-00C04F79EFBC}] [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\VisualStudio\9.0\Generators\{FAE04EC1-301F-11D3-BF4B-00C04F79EFBC}\TransportGeneratorTool] @="TransportGeneratorTool" "CLSID"="{55a6c192-d29f-4e22-84da-dbaf314ed5c3}" "GeneratesDesignTimeSource"=dword:00000001 "GeneratesSharedDesignTimeSource"=dword:00000001

    Read the article

< Previous Page | 1 2