Search Results

Search found 2353 results on 95 pages for 'serial communications'.

Page 2/95 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Network communications mechanisms for SQL Server

    - by Akshay Deep Lamba
    Problem I am trying to understand how SQL Server communicates on the network, because I'm having to tell my networking team what ports to open up on the firewall for an edge web server to communicate back to the SQL Server on the inside. What do I need to know? Solution In order to understand what needs to be opened where, let's first talk briefly about the two main protocols that are in common use today: TCP - Transmission Control Protocol UDP - User Datagram Protocol Both are part of the TCP/IP suite of protocols. We'll start with TCP. TCP TCP is the main protocol by which clients communicate with SQL Server. Actually, it is more correct to say that clients and SQL Server use Tabular Data Stream (TDS), but TDS actually sits on top of TCP and when we're talking about Windows and firewalls and other networking devices, that's the protocol that rules and controls are built around. So we'll just speak in terms of TCP. TCP is a connection-oriented protocol. What that means is that the two systems negotiate the connection and both agree to it. Think of it like a phone call. While one person initiates the phone call, the other person has to agree to take it and both people can end the phone call at any time. TCP is the same way. Both systems have to agree to the communications, but either side can end it at any time. In addition, there is functionality built into TCP to ensure that all communications can be disassembled and reassembled as necessary so it can pass over various network devices and be put together again properly in the right order. It also has mechanisms to handle and retransmit lost communications. Because of this functionality, TCP is the protocol used by many different network applications. The way the applications all can share is through the use of ports. When a service, like SQL Server, comes up on a system, it must listen on a port. For a default SQL Server instance, the default port is 1433. Clients connect to the port via the TCP protocol, the connection is negotiated and agreed to, and then the two sides can transfer information as needed until either side decides to end the communication. In actuality, both sides will have a port to use for the communications, but since the client's port is typically determined semi-randomly, when we're talking about firewalls and the like, typically we're interested in the port the server or service is using. UDP UDP, unlike TCP, is not connection oriented. A "client" can send a UDP communications to anyone it wants. There's nothing in place to negotiate a communications connection, there's nothing in the protocol itself to coordinate order of communications or anything like that. If that's needed, it's got to be handled by the application or by a protocol built on top of UDP being used by the application. If you think of TCP as a phone call, think of UDP as a postcard. I can put a postcard in the mail to anyone I want, and so long as it is addressed properly and has a stamp on it, the postal service will pick it up. Now, what happens it afterwards is not guaranteed. There's no mechanism for retransmission of lost communications. It's great for short communications that doesn't necessarily need an acknowledgement. Because multiple network applications could be communicating via UDP, it uses ports, just like TCP. The SQL Browser or the SQL Server Listener Service uses UDP. Network Communications - Talking to SQL Server When an instance of SQL Server is set up, what TCP port it listens on depends. A default instance will be set up to listen on port 1433. A named instance will be set to a random port chosen during installation. In addition, a named instance will be configured to allow it to change that port dynamically. What this means is that when a named instance starts up, if it finds something already using the port it normally uses, it'll pick a new port. If you have a named instance, and you have connections coming across a firewall, you're going to want to use SQL Server Configuration Manager to set a static port. This will allow the networking and security folks to configure their devices for maximum protection. While you can change the network port for a default instance of SQL Server, most people don't. Network Communications - Finding a SQL Server When just the name is specified for a client to connect to SQL Server, for instance, MySQLServer, this is an attempt to connect to the default instance. In this case the client will automatically attempt to communicate to port 1433 on MySQLServer. If you've switched the port for the default instance, you'll need to tell the client the proper port, usually by specifying the following syntax in the connection string: <server>,<port>. For instance, if you moved SQL Server to listen on 14330, you'd use MySQLServer,14330 instead of just MySQLServer. However, because a named instance sets up its port dynamically by default, the client never knows at the outset what the port is it should talk to. That's what the SQL Browser or the SQL Server Listener Service (SQL Server 2000) is for. In this case, the client sends a communication via the UDP protocol to port 1434. It asks, "Where is the named instance?" So if I was running a named instance called SQL2008R2, it would be asking the SQL Browser, "Hey, how do I talk to MySQLServer\SQL2008R2?" The SQL Browser would then send back a communications from UDP port 1434 back to the client telling the client how to talk to the named instance. Of course, you can skip all of this of you set that named instance's port statically. Then you can use the <server>,<port> mechanism to connect and the client won't try to talk to the SQL Browser service. It'll simply try to make the connection. So, for instance, is the SQL2008R2 instance was listening on port 20080, specifying MySQLServer,20080 would attempt a connection to the named instance. Network Communications - Named Pipes Named pipes is an older network library communications mechanism and it's generally not used any longer. It shouldn't be used across a firewall. However, if for some reason you need to connect to SQL Server with it, this protocol also sits on top of TCP. Named Pipes is actually used by the operating system and it has its own mechanism within the protocol to determine where to route communications. As far as network communications is concerned, it listens on TCP port 445. This is true whether we're talking about a default or named instance of SQL Server. The Summary Table To put all this together, here is what you need to know: Type of Communication Protocol Used Default Port Finding a SQL Server or SQL Server Named Instance UDP 1434 Communicating with a default instance of SQL Server TCP 1433 Communicating with a named instance of SQL Server TCP * Determined dynamically at start up Communicating with SQL Server via Named Pipes TCP 445

    Read the article

  • Linux: Simulate Serial Connection from Arduino

    - by shanet
    I'm trying to simulate the serial connection from an Arduino into a Processing applet since I don't have an Arduino at the moment. Simply, I'm trying to just send bytes from Bash to a serial connection (on /dev/ttyS0) which the Processing applet will pick up like it would from an Arduino. I tried the answer to this question: How can I send data to the serial port from a Linux shell?, but it's simply not working and I don't know how to go about debugging something like this since I've never played with serial connections before. Any advice? Thanks much.

    Read the article

  • Serial port access errors in WINE

    - by goldenmean
    Hello, I have a setup in which I use a USB serial adapter + some application which sends and receives data using that serial usb. But this setup which works on a Windows, or even in a VMWare Virtual windows, does not work under WINE. IT transmits data but i cannot receive data. The cable and the applications are same as in the working and non-working scenarios. I guess The fact that the application works over the USB serial cable just as fine under Virtual Windows(VMware running on linux) by mapping /dev/ttyUSB to the com port, no external software/DLL needed, means it does not need any specific driver. (Am I correct in this assumption that application doesnt need any driver?) (I also tried with a different setup(different USB serial adapter + different application under WINE, but even that does not work under WINE, but it works fine under WIndows/Virtual Windows) How can I get it working under WINE? Any pointers appreciated.

    Read the article

  • Remapping Linux serial port device names

    - by davefiddes
    I have a server running Debian Linux which has a built in serial port which is coming up as ttyS0. I have a plug in PCI card with two serial ports that are being registered with Linux as ttyS2 and ttyS3. Unfortunately I am trying to run some software which assumes that ttyS0 and ttyS1 are available. Is it possible to remap the serial port device names (using a udev rule?) such that ttyS0 remains as it is and ttyS2 becomes ttyS1?

    Read the article

  • Installing and running a guest OS on KVM-qemu with only serial console access

    - by nixnotwin
    I am trying to installing a bsd distro with virt-installer. With a Linux distro I used this: virt-install -n debian -r 1024 --vcpus=1 --accelerate -v --disk /var/kvm/installation-disks/debian.img,size=6--nographics --network=bridge:br0,model=ne2k_pci,mac=52:54:00:66:68:09 -l http://ftp.de.debian.org/debian/dists/squeeze/main/installer-amd64/current/images/ -x console=ttyS0,115200 This loads the installer directly from the online mirror. With Fedora I used this mirror: http://www.nic.funet.fi/pub/mirrors/fedora.redhat.com/pub/fedora/linux/releases/16/Fedora/x86_64/os/ Are there such mirrors for freebsd or openbsd? The reason I want direct installable ftp/http mirrors is because I can access my physical server only via ssh, and it doesn't have a X server or a window manager to give me a VNC GUI. When I tried installing centos 6 with an online mirror I was able to finish the installation via serial console, but after I rebooted it, the serial console never worked for me. I tried everything possible---editing menu.lst, inttab and securtty files. Fedora 16 booted fine from serial console, but got stuck when it loaded anaconda installer. I tried editing freebsd iso installation media by adding serial console option to boot option. And installation was successful. But couldn't boot into it becuase it wasn't giving console acess. I couldn't edit any files as ufs partition cannot be loaded with write access on my Ubuntu server 10.04. Only debian squeeze worked well, it worked for me even without editing a single configuration file. I want to have CLI versions of fedora/centos and freebsd/openbsd. But, looks like there isn't any hope for me to have them, as I have to depend on a serial console to do everything.

    Read the article

  • Connecting a USB laptop to a RJ45 serial port

    - by Jon
    We are about to get our first managed switch at work (Procurve 2520G-24-PoE), and this lowly programmer gets to put on his admin hat and try to configure it. The switch has an RJ45 serial port for console access. My laptop has USB ports but no serial port. In fact, there isn't a single computer in the office with a serial port. I've seen USB-to-DB9 adapters, but I need to go from USB to RJ45 (serial). How would I go about accomplishing this? Do I need two adapters? Will USB-to-DB9 and then DB9-to-RJ45 work? Thanks in advance.

    Read the article

  • Resetting root password on Fedora Core 3 - serial cable access only

    - by Sensible Eddie
    A little background: We have an old rackmount server running a customised version of Fedora, manufactured by a company called Navaho. The server is a TeamCAT, running some proprietary rubbish called Freedom2. We have to keep it going - the alternative is extraordinarily expensive, and the business is not likely to be running much longer to justify changing things. Through one means or another, it has fallen upon me to try and resolve our lack of root access. The previous admin has fallen under the proverbial bus, and nobody has any clue. We have no access to the root account for this server. ssh is running on the server, and there is one account admin that we can login with, however it has no permission to do anything (ironic...) The only other way into the server is with a null-modem serial cable. This works... up to a point. I can see the BIOS, I can see the post BIOS screen, and then I see "Starting grub", followed by another screen with about four lines of Linux information, but then it stops at that point. The server continues booting, and all services come online after around two minutes, but the serial terminal displays no more information. I understand it is possible to put Linux into "single user mode" to reset a root password, but I have no idea how to do this beyond trying to interrupt it at the grub stage listed above. When I have tried it just froze. It was almost like grub had appeared (since the server did not continue booting) but I couldn't see it on the serial terminal. Which made me think maybe the grub screen has some different serial settings? I don't know... it's the first time I've ever used serial for access! A friend of mine suggested trying to use a Fedora boot CD. We could boot from USB, so something along this approach is possible but again we still can only see what's going on with the serial terminal, so it might not be achievable. Does anyone have any suggestions for things I can try? I appreciate this is a bit of a long shot, but any assistance would be invaluable. *UPDATE 1 - 28/8/12 * - we will be making some attempts on this today and will post further details later!

    Read the article

  • Programmatically talking to a Serial Port in OS X or Linux

    - by deadprogrammer
    I have a Prolite LED sign that I like to set up to show scrolling search queries from a apache logs and other fun statistics. The problem is, my G5 does not have a serial port, so I have to use a usb to serial dongle. It shows up as /dev/cu.usbserial and /dev/tty.usbserial . When i do this everything seems to be hunky-dory: stty -f /dev/cu.usbserial speed 9600 baud; lflags: -icanon -isig -iexten -echo iflags: -icrnl -ixon -ixany -imaxbel -brkint oflags: -opost -onlcr -oxtabs cflags: cs8 -parenb Everything also works when I use the serial port tool to talk to it. If I run this piece of code while the above mentioned serial port tool, everthing also works. But as soon as I disconnect the tool the connection gets lost. #!/usr/bin/python import serial ser = serial.Serial('/dev/cu.usbserial', 9600, timeout=10) ser.write("<ID01><PA> \r\n") read_chars = ser.read(20) print read_chars ser.close() So the question is, what magicks do I need to perform to start talking to the serial port without the serial port tool? Is that a permissions problem? Also, what's the difference between /dev/cu.usbserial and /dev/tty.usbserial?

    Read the article

  • Serial: write() throttling?

    - by damian
    Hi everyone, I'm working on a project sending serial data to control animation of LED lights, which need to stay in sync with a sound engine. There seems to be a large serial write buffer (OSX (POSIX) + FTDI chipset usb serial device), so without manually restricting the transmission rate, the animation system can get several seconds ahead of the serial transmission. Currently I'm manually restricting the serial write speed to the baudrate (8N1 = 10 bytes serial frame per 8 bytes data, 19200 bps serial - 1920 bytes per second max), but I am having a problem with the sound drifting out of sync over time - it starts fine, but after 10 minutes there's a noticeable (100ms+) lag between the sound and the lights. This is the code that's restricting the serial write speed (called once per animation frame, 'elapsed' is the duration of the current frame, 'baudrate' is the bps (19200)): void BufferedSerial::update( float elapsed ) { baud_timer += elapsed; if ( bytes_written > 1024 ) { // maintain baudrate float time_should_have_taken = (float(bytes_written)*10)/float(baudrate); float time_actually_took = baud_timer; // sleep if we have > 20ms lag between serial transmit and our write calls if ( time_should_have_taken-time_actually_took > 0.02f ) { float sleep_time = time_should_have_taken - time_actually_took; int sleep_time_us = sleep_time*1000.0f*1000.0f; //printf("BufferedSerial::update sleeping %i ms\n", sleep_time_us/1000 ); delayUs( sleep_time_us ); // subtract 128 bytes bytes_written -= 128; // subtract the time it should have taken to write 128 bytes baud_timer -= (float(128)*10)/float(baudrate); } } } Clearly there's something wrong, somewhere. A much better approach would be to be able to determine the number of bytes currently in the transmit queue, and try and keep that below a fixed threshold. Any advice appreciated.

    Read the article

  • Microsoft products such as Visual Studio 2010 does not require to enter serial number

    - by MainMa
    Hi, I am member of WebsiteSpark and was member of DreamSpark. Both programs enable to download software and provide serial keys to use. Some software like Windows Server has an ISO file to download and a serial number displayed on the website which I must enter during installation. Some other software does not have any serial key. For example, when I downloaded Visual Studio 2010, there was just a link to an ISO file. During installation, there was no such a field as serial number (whereas Visual Studio 2008 had this field at the beginning of installation process). There is the same thing with SQL Server 2008 and Microsoft Expression Studio 3. Even when I've downloaded the public trial RTM version of Windows Seven Enterprise, there were no serial number to enter. I don't think that such expensive products as SQL Server 2008 Enterprise are delivered without serials and online validation, so I suppose that the serial is embedded into the product itself, either in installation binaries or in a separate config file, so is already in the ISO I download so I do not have to enter it. So my question is, how it is done technically? Is each 2 GBs ISO generated on-demand on the server to embed a serial each time this ISO is requested? I suppose that if it is done, it has a huge impact on servers performance (no caching, no streaming...), so what may be the techniques used behind? I want to implement the same feature in a product I intend to ship (to simplify installation by avoiding to ask to enter serial number), but I really don't see how to do it with low impact on server performance.

    Read the article

  • Virtualbox and Serial Port permissions

    - by Pandincus
    I have a Windows XP Pro SP3 host machine running a Windows XP Pro SP3 guest machine. The host machine has one serial port, COM1, that I need to use in the guest machine. When I add the serial port to the guest machine and try to start it, I get the following error: Failed to start the virtual machine xxx Cannot open host device 'COM1' for read/write access. Check the permissions of that device (VERR_ACCESS_DENIED). Unknown error creating VM (VERR_ACCESS_DENIED). What are some of the things that might be causing this problem? How can I check "permissions" on a serial port?

    Read the article

  • VirtualBox serial port, limit of two?

    - by Evan Carroll
    Using VirtualBox, Is there a limit of two serial ports per VM? I'm currently engaging in a task that requires more than two, but less than or equal to four ports. I'm at a loss of what to do to get COM3 and COM4 up? How do I do it if the Virtual Box GUI doesn't currently support more than two serial host devices? Can I configure them external to the GUI? Is there a hard-cap on two devices? And, if so, for the love of god, please entertain me with the reasoning? I know Windows and Linux don't impose such a limit, it would seem awkward to impose it in virtualization layer. This is for cheap dial-in project with proprietary Windows tools. I'm using a Quatech serial multiport adapter to provide the ports to multimodems.

    Read the article

  • Get HDD (and NOT Volume) Serial Number on Vista Ultimate 64 bit

    - by TheAgent
    Hi all. I was once looking for getting the HDD serial number without using WMI, and I found it. The code I found and posted on StackOverFlow.com works very well on 32 bit Windows, both XP and Vista. The trouble only begins when I try to get the serail number on 64 bit OSs (Vista Ultimate 64, specifically). The code returns String.Empty, or a Space all the time. Anyone got an idea how to fix this? EDIT: I used the tools Dave Cluderay suggested, with interesting results: Here is the output from DiskId32, on Windows XP SP2 32-bit: To get all details use "diskid32 /d" Trying to read the drive IDs using physical access with admin rights Drive 0 - Primary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Trying to read the drive IDs using the SCSI back door Drive 4 - Tertiary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Trying to read the drive IDs using physical access with zero rights **** STORAGE_DEVICE_DESCRIPTOR for drive 0 **** Vendor Id = [] Product Id = [MAXTOR STM3160215AS] Product Revision = [3.AAD] Serial Number = [] **** DISK_GEOMETRY_EX for drive 0 **** Disk is fixed DiskSize = 160041885696 Trying to read the drive IDs using Smart Drive 0 - Primary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Hard Drive Serial Number__________: 6RA26XK3 Hard Drive Model Number___________: MAXTOR STM3160215AS And DiskId32 run on Windows Vista Ultimate 64-bit: To get all details use "diskid32 /d" Trying to read the drive IDs using physical access with admin rights Trying to read the drive IDs using the SCSI back door Trying to read the drive IDs using physical access with zero rights **** STORAGE_DEVICE_DESCRIPTOR for drive 0 **** Vendor Id = [MAXTOR S] Product Id = [TM3160215AS] Product Revision = [3.AA] Serial Number = [] **** DISK_GEOMETRY_EX for drive 0 **** Disk is fixed DiskSize = 160041885696 Trying to read the drive IDs using Smart Hard Drive Serial Number__________: Hard Drive Model Number___________: Notice how much lesser the information is on Vista, and how the Serial Number is not returned. Also the other tool, EnumDisk, refers to my hard disks on Vista as "SCSI" as opposed to "ATA" on Windows XP. Any ideas? EDIT 2: I'm posting the results from EnumDisks: On Windows XP SP2 32-bit: Properties for Device 1 Device ID: IDE\DiskMAXTOR_STM3160215AS_____________________3.AAD___ Adapter Properties ------------------ Bus Type : ATA Max. Tr. Length: 0x20000 Max. Phy. Pages: 0xffffffff Alignment Mask : 0x1 Device Properties ----------------- Device Type : Direct Access Device (0x0) Removable Media : No Product ID : MAXTOR STM3160215AS Product Revision: 3.AAD Inquiry Data from Pass Through ------------------------------ Device Type: Direct Access Device (0x0) Vendor ID : MAXTOR S Product ID : TM3160215AS Product Rev: 3.AA Vendor Str : *** End of Device List

    Read the article

  • cannot read but can write on serial port through Android Emulator

    - by Aad
    I am working on a program that is communicating with serial port over USB through Android emulator. emulator -qemu -serial /dev/ttyUSB0 The emulator is able to open the port and write into it. However, read is not happening. The program has a timeout for read maintained by a timer. The read happens in a separate 'read' thread. The main thread has a socketpair fd pair to signal the read-thread that the serial port is closed post timeout. In the read-thread, polling happens(poll() function call) over the 2 file-descriptors: one is serial port fd, the other is one of the socketpair. The board that I have connected to works fine with sending commands over 'cutecom' The poll never succeeds for serial port. However, poll succeeds for 'socketpair'ed fd and the thread ends on a close-signal sent from main-thread post timeout. Ouestions: Are there any special settings for read as even loop-back fails Are there differences between settings for read and write on a serial port?

    Read the article

  • How to power a serial port under linux?

    - by Lex
    I got a serial to ethernet device connected to a Serial (COM) port on a Linux machine (debian etch), I connected it correctly but it did not power up, I suppose I need to power the device port, anyone knows how to power it under linux? Thankyou in advance.

    Read the article

  • Sharing a serial port between two processes

    - by peterrus
    As it is not possible to directly share a serial port between two processes using Linux, I am looking for another way to achieve this, I have heard about socat but could not find a concrete example of how to realize the following: Split one physical serial port (/dev/ttyUSB0) into two virtual ports, one for reading and one for writing, as one process only needs to send data, and one only needs to receive data. I can no modify the sending application unfortunately.

    Read the article

  • Raspberry Pi broadcast serial port data to local network

    - by D051P0
    I didn't find anything to help me with this problem. What I want is: Serial device sends repeatedly some data to serial port. Raspberry Pi should get this data from RxD and stream it to local network via port 10001 without filtering it. So I can find this device on my pc. This should also work in other direction: Raspberry listen to port 10001 and forward all data from local network to TxD. I'm newbie in Linux World. How can I listen to some port on Raspberry Pi and send broadcast to the same port? I'm using Raspbian Wheezy with soft float. I have found a library Pi4j for Java, that I already use to get and write data from/to serial port. final Serial serial = SerialFactory.createInstance(); serial.addListener(new SerialDataListener() { public void dataReceived(SerialDataEvent event) { forward(event.getData()); } }); event.getData() is a String, which I want to broadcast in my local network. Is it generally a good Idea to use Java for that? I need also a String from port 10001, which I can forward to serial port.

    Read the article

  • Installing UCMA 3.0 and Creating a Communications Server "14"Trusted Application Pool

    A lot of setup and administration tasks have gotten a lot easier in Communications Server 14; one of them is building an application server to develop and run your UCMA 3.0 applications on. In this post, Ill walk you through installing the UCMA 3.0 Core SDK and creating a Trusted Application Pool on the server, thus adding it to the Communications Server 14 topology and allowing you to host and run UCMA 3.0 applications on it. Note: These instructions will change slightly as the bits get updated for the eventual Beta release I will update this post as soon as I get a chance to run this setup on a more recent build. Im doing the install on a simple Communications Server 14 topology consisting of the following Windows Server 2008 R2 Hyper-V images: DC Domain Controller ExchangeUM Exchange Server 2010 CS-SE Microsoft Communications Server 2010 Standard Edition TS Development machine Ill walk through setting up UCMA 3.0 on the TS VM, which is a fully patched Windows Server 2008 R2 machine that is joined to the Fabrikam domain.   Im also running Visual Studio 2010 on this VM because I intend to use it as a development machine.  In a future post, Ill walk through installing just the UCMA 3.0 run time to build a true production UCMA application server. Im making a couple of assumptions here: You have an existing CS 2010 site and cluster configured(well look at this in a future post) Youre starting with a fully patched Windows Server 2008 R2 machine The machine is joined to your domain This walkthrough was done in my Fabrikam VM environment but can easily be modified for your own environment. Installing the UCMA 3.0 SDK Lets start by installing the UCMA 3.0 SDK.  Run UcmaSdkWebDownload.msi to kick off the SDK installer package extract process. The installed package is extracted to C: >> Program Files >> Microsoft UCMA 3.0 >> SDK Installer Package.  Browse there and run setup.exe. Click Install to install the UCMA 3.0 Core SDK and Workflow SDK. Install Communications Server Core Components UCMA 3.0 introduces a new concept called Auto-provisioning, which is most easily explained from the developer point of view.  Remember what your app.config looked it in UCMA 2.0?  You had to store the application GRUU, the trusted contact SIP Uri, the port for your application, and the name of the certificate authority. Thats all gone with auto-provisioning all you need in your app.config is your ApplicationId, e.g.: urn:application:MyApplication. How does CS 2010 do this? All of the applications configuration data is associated with the applications id.  UCMA also queries a replicated copy of the Central Management Database to retrieve the applications configuration data and also the configuration data for any endpoints. In this step, well run Bootstrapper.exe to install the CS Core components, this checked for the following components and installs them if they are not already present: VcRedist Sqlexpress Sqlnativeclient Sqlbackcompat Ucmaredist OcsCore.msi Open a command window at C: >> Program Files >> Microsoft Communications Server 2010 >> Deployment and run the following command: Bootstrapper.exe /BootstrapReplica /MinCache /SourceDirectory:"%ProgramFiles%\Microsoft UCMA 3.0\SDK Installer Package\Prereq\BootstrapperCache" Create a New Trusted Application Pool The next step is to create a new trusted application pool for the new server.  Fire up the Communications Server Management Shell from Start >> Microsoft Communications Server 2010 >> Communications Server Management Shell and enter the following PowerShell command: New-CsTrustedApplicationPool -Identity <FQDN of Server> -Registrar <FQDN of CS Server> -Site <CS Site Name> Verify that the new server was added to the CS topology by running the following PowerShell command: (Get-CsTopology -AsXml).ToString() > Topology.xml This created a file called Topology.xml in the directory that you ran the command from.  Open the file and find the Clusters section and look for a node for the new server. The Cluster Fqdn is the name of your server, and note the name of the Site that this Cluster is a part of. <Cluster Fqdn="appsrv.fabrikam.com" RequiresReplication="true" RequiresSetup="true"> <ClusterId SiteId="UcMarketing2" Number="5" /> <Machine OrdinalInCluster="1" Fqdn="appsrv.fabrikam.com"> <NetInterface InterfaceSide="Primary" InterfaceNumber="1" IPAddress="0.0.0.0" /> </Machine> </Cluster> Configure CS Management Store Replication At this point, we have the CS Core components installed and the server configured as a trusted application pool.  We now need to set up replication so that the Central Management Store replicates down to the new server. From the Communications Server Management Shell, run the following PowerShell command to enable the Replica service on the new server: Enable-CSReplica The Replica service is enabled, but hasn't done anything yet. This can be verified by running the following PowerShell command to check the replication status for the various servers in the topology: Get-CSManagementStoreReplicationStatus You can see in the screenshot below that the UpToDate property of the new server is still False Run the following PowerShell command to force the replication to run: Invoke-CSManagementStoreReplicationStatus Run Get-CSManagementStoreReplicationStatus again to verify that the new service is now up to date Request and Set a New Certificate The last step in the process is to request a new certificate from the certificate authority on the domain and assign it to the new server. From the Communications Server Management Shell, run the following PowerShell command to request a new certificate: Request-CSCertificate -Action new -Type default -CA <Domain Controller FQDN>\<Certificate Authority> Setting the -Verbose switch on the cmdlet creates an Xml file with its output. Open the Xml file and copy the thumbprint of the generated certificate. <?xml version="1.0" encoding="utf-8"?> <Action Name="Request-CsCertificate" Time="20100512T212258"> <Action Name="Request-CsCertificate" Time="20100512T212258"> <Info Title="Connection" Time="20100512T212258">Data Source=(local)\rtclocal;Initial Catalog=xds;Integrated Security=True</Info> <Action Time="20100512T212258"> <Info Title="Certificate use" Time="20100512T212258">urn:certref:default</Info> <Info Title="Subject distinguished name" Time="20100512T212258">CN="appsrv2.fabrikam.com"</Info> <Info Time="20100512T212259">The certificate request is submitted to the Certification Authority dc.fabrikam.com\FabrikamCA.</Info> <Info Time="20100512T212259">The certificate was issued.</Info> <Info Time="20100512T212259">The certificate was imported with thumbprint AFC3C46E459C1A39AD06247676F3555826DBF705.</Info> <Complete Time="20100512T212259" /> </Action> <Info Title="command status" Time="20100512T212259">Command execution processing completed</Info> <Action Name="DeploymentXdsCmdlet.SaveCachedItems" Time="20100512T212259"> <Info Time="20100512T212259">0 updates</Info> <Complete Time="20100512T212259" /> </Action> <Info Title="command status" Time="20100512T212259">Command has completed</Info> </Action> </Action> Run the following PowerShell command to set the certificate: Set-CsCertificate -Type Default -Thumbprint <Thumbprint> Wrapping Up You now have a new UCMA 3.0 application server in your Communications Server 2010 server topology.  You can provision trusted applications and trusted application endpoints on the new server using the Communications Server 2010 Management Shell.  Well take a look at how to do that in another post. Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • USB-to-Serial showing gibberish at 115200 Baud

    - by Mose
    I've got a serious problem which drives me crazy because I tried everything I could think of. First of all, I made a video: http://youtu.be/boghkuq7L_s but please read the following text for more information, not only view the video! When using a USB-to-Serial interface everything works as long as I don't go beyond 57600 Baud. At higher rates I only get giberish like this: év.­b0JNLYÆÿ¿iëd0U²(kßÞb! ú]/xscB!ï¯!BoXûÿ1ïâÖCÿ6ÌAnè*íÌC)º¿BíÞØ.C.@ÆÃwHJÂs "YE:ñ.èFðÌCÊ÷ÞÄ !x H w6@BtbHJ ̪ Ì6ì H¾a¿bH.">îvy®;f<ßBÌ p­L¨fæH­E ­þ¼MBÞI What makes the problem so strange is, I exchanged every component and the problem still presists. I tried differtent OSes (Ubuntu, WinXP, Win7, OSX 10.7) with 32 and 64 Bit. I tried USB-to-Serial interface from FTDI and Prolific. I tried reading the output from my Raspberry PI and from an Asterisk Appliance. I changed the cables and the wiring. Nothing helped. In the video I made a example with a old Notebook with native COM and put the USB-to-Serial to the same connection as "sniffer" (only Rx and GND connected) to make sure the output and everything is ok as one can see on the native port. The voltage is ok. Settings for both are 115200 Baud, 8 Bit with 1 Stop and no flow control. Native is ok. USB is messed up. I used the newest drivers and double checked all connections. I have no idea what is wrong here. As I couldn't find anyone describing problems like this I question my long experiance in computer science and think I'm doing some completly wrong... Please help :-/

    Read the article

  • Webinar: Oracle Commerce Best Practices for the Communications Industry

    - by Jeri Kelley
    In today’s volatile economy, Communications Service Providers are challenged to offer a complete, cross-channel commerce experience. With Oracle Commerce solutions, CSPs can get closer to customers and gain valuable insight to maximize ROI across all commerce activities. Join us for a  live webcast on September 26th with featured speakers Raghavendra Ademane, Omni-Channel Commerce Consultant at Professional Access and Brenna Johnson, Product Manager, Oracle and learn how you can manage and deliver commerce experiences for Communications that engage customers and promote loyalty. The panelists will guide you through a number of topics including: Current Communications market trends, opportunities and challenges Introduction to the Oracle Commerce solution with case studies Demonstration of the solution for Communications with live Q&A Register today and learn how Oracle's latest innovations for Communications can help you increase online sales and enhance cross-channel commerce interactions.

    Read the article

  • Oracle Commerce Best Practices for the Communications Industry

    - by Michael Seback
      In today’s volatile economy, Communications Service Providers are challenged to offer a complete, cross-channel commerce experience. With Oracle Commerce solutions, CSPs can get closer to customers and gain valuable insight to maximize ROI across all commerce activities. Join us for a  live webcast on September 26th with featured speakers Raghavendra Ademane, Omni-Channel Commerce Consultant at Professional Access and Brenna Johnson, Product Manager, Oracle and learn how you can manage and deliver commerce experiences for Communications that engage customers and promote loyalty. The panelists will guide you through a number of topics including: Current Communications market trends, opportunities and challenges Introduction to the Oracle Commerce solution with case studies Demonstration of the solution for Communications with live Q&A Register today and learn how Oracle's latest innovations for Communications can help you increase online sales and enhance cross-channel commerce interactions.

    Read the article

  • Advice on logic circuits and serial communications

    - by Spencer Ruport
    As far as I understand the serial port so far, transferring data is done over pin 3. As shown here: There are two things that make me uncomfortable about this. The first is that it seems to imply that the two connected devices agree on a signal speed and the second is that even if they are configured to run at the same speed you run into possible synchronization issues... right? Such things can be handled I suppose but it seems like there must be a simpler method. What seems like a better approach to me would be to have one of the serial port pins send a pulse that indicates that the next bit is ready to be stored. So if we're hooking these pins up to a shift register we basically have: (some pulse pin)-clk, tx-d Is this a common practice? Is there some reason not to do this? EDIT Mike shouldn't have deleted his answer. This I2C (2 pin serial) approach seems fairly close to what I did. The serial port doesn't have a clock you're right nobugz but that's basically what I've done. See here: private void SendBytes(byte[] data) { int baudRate = 0; int byteToSend = 0; int bitToSend = 0; byte bitmask = 0; byte[] trigger = new byte[1]; trigger[0] = 0; SerialPort p; try { p = new SerialPort(cmbPorts.Text); } catch { return; } if (!int.TryParse(txtBaudRate.Text, out baudRate)) return; if (baudRate < 100) return; p.BaudRate = baudRate; for (int index = 0; index < data.Length * 8; index++) { byteToSend = (int)(index / 8); bitToSend = index - (byteToSend * 8); bitmask = (byte)System.Math.Pow(2, bitToSend); p.Open(); p.Parity = Parity.Space; p.RtsEnable = (byte)(data[byteToSend] & bitmask) > 0; s = p.BaseStream; s.WriteByte(trigger[0]); p.Close(); } } Before anyone tells me how ugly this is or how I'm destroying my transfer speeds my quick answer is I don't care about that. My point is this seems much much simpler than the method you described in your answer nobugz. And it wouldn't be as ugly if the .Net SerialPort class gave me more control over the pin signals. Are there other serial port APIs that do?

    Read the article

  • Check if serial port is listening

    - by Hyposaurus
    I have an Arduino sending and receiving instructions with a python script via a serial port. The Arduino takes a button state and when it is pushed it will send a message via serial to a python script and await a response. (via Serial.available()). Works well enough. However if the python script has crashed for whatever reason (ideally it will run in the background, so cant be easily checked) the Arduino will wait forever and even on a script restart will we unavailable. Is there a way for my Arduino to check if there is something listening on the serial port? (and alert me with flashing lights etc if not) or is this not how serial works? Worst case I guess I could use a timeout, although that is not ideal.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >