Search Results

Search found 2649 results on 106 pages for 'signal slot'.

Page 2/106 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • How to change FPU context in signal handler (C++/Linux)

    - by Henry Fané
    I wrote a signal handler to catch FPE errors. I need to continue execution even if this happens. I receive a ucontext_t as parameter, I can change the bad operand from 0 to another value but the FPU context is still bad and I run into an infinite loop ? Does someone already manupulate the ucontext_t structure on Linux ? I finally found a way to handle these situations by clearing the status flag of ucontext_t like this: ... const long int cFPUStatusFlag = 0x3F; aContext->uc_mcontext.fpregs->sw &= ~cFPUStatusFlag; ... 0x3F is negated to put 0 in the 6 bits of the status register of the FPU (x87). Doing this implies to check for FPE exceptions after calculation.

    Read the article

  • Android Signal analysis + some filters.

    - by Profete162
    Hello, as the world cup is the main sport event and the Vuvuzelas are the most annoying sound in the world, I had an idea to remove them definitively by reading this new ( http://www.popsci.com/diy/article/2010-06/simple-software-can-filter-out-vuvuzela-whine) that told us that the sound has some frequencies at 233Hz + 466,932,1864Hz. I have already made a lot of Android application by myself but never touching the signal analysis and filtering part, so here are a few questions, I do not ask for precise answer but maybe links and tutorial to find something to work on. I guess that a new Android phone has the CPU and power to make real-time filtering. 1) How can I intercept the sound coming from the Jack microphone - Line-IN plug- ( I plan to link my TV to my phone with Jack to Jack plug). My question is totally software and coding, I have all the wires and adapters to plug a jack into my android phone Line IN. 2) Are there some Fourier analysis librairies, may I have a look to Java libraries on the web and import them to my Android project? I really apologize because my question seem not precise, but I think that would be something great. Thank you for your answers.

    Read the article

  • SQL SERVER – Signal Wait Time Introduction with Simple Example – Wait Type – Day 2 of 28

    - by pinaldave
    In this post, let’s delve a bit more in depth regarding wait stats. The very first question: when do the wait stats occur? Here is the simple answer. When SQL Server is executing any task, and if for any reason it has to wait for resources to execute the task, this wait is recorded by SQL Server with the reason for the delay. Later on we can analyze these wait stats to understand the reason the task was delayed and maybe we can eliminate the wait for SQL Server. It is not always possible to remove the wait type 100%, but there are few suggestions that can help. Before we continue learning about wait types and wait stats, we need to understand three important milestones of the query life-cycle. Running - a query which is being executed on a CPU is called a running query. This query is responsible for CPU time. Runnable – a query which is ready to execute and waiting for its turn to run is called a runnable query. This query is responsible for Signal Wait time. (In other words, the query is ready to run but CPU is servicing another query). Suspended – a query which is waiting due to any reason (to know the reason, we are learning wait stats) to be converted to runnable is suspended query. This query is responsible for wait time. (In other words, this is the time we are trying to reduce). In simple words, query execution time is a summation of the query Executing CPU Time (Running) + Query Wait Time (Suspended) + Query Signal Wait Time (Runnable). Again, it may be possible a query goes to all these stats multiple times. Let us try to understand the whole thing with a simple analogy of a taxi and a passenger. Two friends, Tom and Danny, go to the mall together. When they leave the mall, they decide to take a taxi. Tom and Danny both stand in the line waiting for their turn to get into the taxi. This is the Signal Wait Time as they are ready to get into the taxi but the taxis are currently serving other customer and they have to wait for their turn. In other word they are in a runnable state. Now when it is their turn to get into the taxi, the taxi driver informs them he does not take credit cards and only cash is accepted. Neither Tom nor Danny have enough cash, they both cannot get into the vehicle. Tom waits outside in the queue and Danny goes to ATM to fetch the cash. During this time the taxi cannot wait, they have to let other passengers get into the taxi. As Tom and Danny both are outside in the queue, this is the Query Wait Time and they are in the suspended state. They cannot do anything till they get the cash. Once Danny gets the cash, they are both standing in the line again, creating one more Signal Wait Time. This time when their turn comes they can pay the taxi driver in cash and reach their destination. The time taken for the taxi to get from the mall to the destination is running time (CPU time) and the taxi is running. I hope this analogy is bit clear with the wait stats. You can check the Signalwait stats using following query of Glenn Berry. -- Signal Waits for instance SELECT CAST(100.0 * SUM(signal_wait_time_ms) / SUM (wait_time_ms) AS NUMERIC(20,2)) AS [%signal (cpu) waits], CAST(100.0 * SUM(wait_time_ms - signal_wait_time_ms) / SUM (wait_time_ms) AS NUMERIC(20,2)) AS [%resource waits] FROM sys.dm_os_wait_stats OPTION (RECOMPILE); Higher the Signal wait stats are not good for the system. Very high value indicates CPU pressure. In my experience, when systems are running smooth and without any glitch the Signal wait stat is lower than 20%. Again, this number can be debated (and it is from my experience and is not documented anywhere). In other words, lower is better and higher is not good for the system. In future articles we will discuss in detail the various wait types and wait stats and their resolution. Read all the post in the Wait Types and Queue series. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL DMV, SQL Performance, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQL Wait Stats, SQL Wait Types, T SQL, Technology

    Read the article

  • Inspiron N7110 Ubuntu 12.04 Poor WiFi Signal

    - by Joseph Risley
    Sorry if this is a repeat, I have been Googling possible answers and have not found one yet. I find my wireless signal is never 100%. Speed is fine, it's the actual signal strength that is the issue. I thought my router was the issue, but the problem was also present at the public library today. I asked the Windows and Mac users around me about their signal strength and they had full signal while mine was medium to low according to WiFiRadar. Is this a Dell problem (Realtek), or an Ubuntu problem I can fix in the terminal?

    Read the article

  • Generating a scalogram of a signal

    - by Goz
    Hi there, I'm trying to build a scalogram view for my app to see whether there is relevant information we can retrieve from a wavelet transform as opposed to using a spectograms to see what can be retrieved via an FFT. So far I can take a wave form and I can perform the forward wavelet transform on it. However I am lost at the next step. How do I turn this information into power/energy information? I have a set of wave forms at different frequencies but I have, as I say, no frequency information. Can anyone tell me what the next step is for turning this transformed data into a scalogram? Any help would be much appreciated because my google skills are failing me!

    Read the article

  • Filter design for audio signal.

    - by beanyblue
    What I am trying to do is simple. I have a few .wav files. I want to remove noise and filter out specific frequencies. I don't have matlab and I intend to write my own code for all the filters. Right now, I have a way to read the .wav file and dump out the structure into a text file. My questions are the following: Can I directly apply the digital filters on this sampled data?{ ie, can I directly do a convolution between my input samples and h(n) for the filter function that i choose?). How do I choose the number of coefficients for the Window function? I have octave, so if someone can point me to anything that gives me some idea on how to process the .wav file using octave, that would be great too. I want to be able to filter out the frequency and then listen to the sound again. Is this possible with octave? I'm just a beginner with these kinds of things, so please bear with me if my questions are too naive. Any help will be great.

    Read the article

  • Apache 2.2, worker mpm, mod_fcgid and PHP: Can't apply process slot

    - by mopoke
    We're having an issue on an apache server where every 15 to 20 minutes it stops serving PHP requests entirely. On occasions it will return a 503 error, other times it will recover enough to serve the page but only after a delay of a minute or more. Static content is still served during that time. In the log file, there's errors reported along the lines of: [Wed Sep 28 10:45:39 2011] [warn] mod_fcgid: can't apply process slot for /xxx/ajaxfolder/ajax_features.php [Wed Sep 28 10:45:41 2011] [warn] mod_fcgid: can't apply process slot for /xxx/statics/poll/index.php [Wed Sep 28 10:45:45 2011] [warn] mod_fcgid: can't apply process slot for /xxx/index.php [Wed Sep 28 10:45:45 2011] [warn] mod_fcgid: can't apply process slot for /xxx/index.php There is RAM free and, indeed, it seems that more php processes get spawned. /server-status shows lots of threads in the "W" state as well as some FastCGI processes in "Exiting(communication error)" state. I rebuilt mod_fcgid from source as the packaged version was quite old. It's using current stable version (2.3.6) of mod_fcgid. FCGI config: FcgidBusyScanInterval 30 FcgidBusyTimeout 60 FcgidIdleScanInterval 30 FcgidIdleTimeout 45 FcgidIOTimeout 60 FcgidConnectTimeout 20 FcgidMaxProcesses 100 FcgidMaxRequestsPerProcess 500 FcgidOutputBufferSize 1048576 System info: Linux xxx.com 2.6.28-11-server #42-Ubuntu SMP Fri Apr 17 02:45:36 UTC 2009 x86_64 GNU/Linux DISTRIB_ID=Ubuntu DISTRIB_RELEASE=9.04 DISTRIB_CODENAME=jaunty DISTRIB_DESCRIPTION="Ubuntu 9.04" Apache info: Server version: Apache/2.2.11 (Ubuntu) Server built: Aug 16 2010 17:45:55 Server's Module Magic Number: 20051115:21 Server loaded: APR 1.2.12, APR-Util 1.2.12 Compiled using: APR 1.2.12, APR-Util 1.2.12 Architecture: 64-bit Server MPM: Worker threaded: yes (fixed thread count) forked: yes (variable process count) Server compiled with.... -D APACHE_MPM_DIR="server/mpm/worker" -D APR_HAS_SENDFILE -D APR_HAS_MMAP -D APR_HAVE_IPV6 (IPv4-mapped addresses enabled) -D APR_USE_SYSVSEM_SERIALIZE -D APR_USE_PTHREAD_SERIALIZE -D SINGLE_LISTEN_UNSERIALIZED_ACCEPT -D APR_HAS_OTHER_CHILD -D AP_HAVE_RELIABLE_PIPED_LOGS -D DYNAMIC_MODULE_LIMIT=128 -D HTTPD_ROOT="" -D SUEXEC_BIN="/usr/lib/apache2/suexec" -D DEFAULT_PIDLOG="/var/run/apache2.pid" -D DEFAULT_SCOREBOARD="logs/apache_runtime_status" -D DEFAULT_ERRORLOG="logs/error_log" -D AP_TYPES_CONFIG_FILE="/etc/apache2/mime.types" -D SERVER_CONFIG_FILE="/etc/apache2/apache2.conf" Apache modules loaded: alias.load auth_basic.load authn_file.load authz_default.load authz_groupfile.load authz_host.load authz_user.load autoindex.load cgi.load deflate.load dir.load env.load expires.load fcgid.load headers.load include.load mime.load negotiation.load rewrite.load setenvif.load ssl.load status.load suexec.load PHP info: PHP 5.2.6-3ubuntu4.6 with Suhosin-Patch 0.9.6.2 (cli) (built: Sep 16 2010 19:51:25) Copyright (c) 1997-2008 The PHP Group Zend Engine v2.2.0, Copyright (c) 1998-2008 Zend Technologies

    Read the article

  • AGP 4x slot running at 2x

    - by Wesley
    Hi all, Here are the specs of the machine related to this question: AMD Athlon XP 2400+ @ 2 GHz / 2x 512MB PC3200 DDR RAM / 3D Fuzion 128MB GeForce 6200 AGP / WD 160GB IDE HDD / FIC AM37 (mobo) / Codegen 350W PSU / Windows XP Pro SP3 So, for some odd reason, the GeForce 6200 that is in the AGP 4x slot is not running at 4x, but 2x. The card itself supports AGP 4x and even 8x. When I enter the BIOS, the options for the AGP slot only allow 2x as the max. Before, the max option for the AGP slot in the BIOS was 4x. (I do get the 4x option after I reset CMOS, but it does not stick after a restart.) I don't exactly know what the problem could be, but a few weeks ago, this machine's hard drive was reformatted and got a fresh install of XP. Also, I did install Rivatuner, but I never overclocked it at all. (I uninstalled it after thinking that it had done something.) Otherwise, I cannot figure out the cause of the problem. Does anybody have an idea why this is happening? (Would I have to do another reformat?) Thanks in advance. PS: the other options for the AGP slot are aperture size (which I tried changing, but it did nothing) and FastWrite (enabled by default).

    Read the article

  • Reusing slot numbers in Linux software RAID arrays

    - by thkala
    When a hard disk drive in one of my Linux machines failed, I took the opportunity to migrate from RAID5 to a 6-disk software RAID6 array. At the time of the migration I did not have all 6 drives - more specifically the fourth and fifth (slots 3 and 4) drives were already in use in the originating array, so I created the RAID6 array with a couple of missing devices. I now need to add those drives in those empty slots. Using mdadm --add does result in a proper RAID6 configuration, with one glitch - the new drives are placed in new slots, which results in this /proc/mdstat snippet: ... md0 : active raid6 sde1[7] sdd1[6] sda1[0] sdf1[5] sdc1[2] sdb1[1] 25185536 blocks super 1.0 level 6, 64k chunk, algorithm 2 [6/6] [UUUUUU] ... mdadm -E verifies that the actual slot numbers in the device superblocks are correct, yet the numbers shown in /proc/mdstat are still weird. I would like to fix this glitch, both to satisfy my inner perfectionist and to avoid any potential sources of future confusion in a crisis. Is there a way to specify which slot a new device should occupy in a RAID array? UPDATE: I have verified that the slot number persists in the component device superblock. For the version 1.0 superblocks that I am using that would be the dev_number field as defined in include/linux/raid/md_p.h of the Linux kernel source. I am now considering direct modification of said field to change the slot number - I don't suppose there is some standard way to manipulate the RAID superblock?

    Read the article

  • Laptop with Intel Graphics: external VGA monitor only gets signal on boot (no "hot plugging")

    - by iveand
    I am able to get an external VGA monitor (or projector) to work if I start my laptop with it connected. However, if I start the laptop with it disconnected there is no signal on the external. The Displays screen shows the external, and thinks that it is active, but there is no signal being sent to it. This has been a persistent problem since 10.04 (I am now on 12.04.... each upgrade hoping something is improved). I should note that even when it works (starting with display connected), Displays still says the monitor is "unknown" (but it sends the signal). For the correct resolution to display, I have had to add a few xrandr lines for my monitor to my .xprofile file... otherwise resolution is limited to default 1024x768. So, resolution issues can be worked around, but the main issue is that the external doesn't get a signal without starting the machine with it connected. I have tried: adding i915.modeset=1 to grub (also i965.modeset=1 since someone posted that this helped even though lshw shows i915) adding following ppa and doing a dist-upgrade: sudo add-apt-repository ppa:xorg-edgers/ppa Here are the details: Laptop: Toshiba Tecra M10 lspci listings for video: 00:02.0 VGA compatible controller [0300]: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller [8086:2a42] (rev 07) sudo lshw -C video listing: *-display:0 description: VGA compatible controller product: Mobile 4 Series Chipset Integrated Graphics Controller vendor: Intel Corporation physical id: 2 bus info: pci@0000:00:02.0 version: 07 width: 64 bits clock: 33MHz capabilities: msi pm vga_controller bus_master cap_list rom configuration: driver=i915 latency=0 resources: irq:46 memory:ff400000-ff7fffff memory:e0000000-efffffff ioport:cff8(size=8) *-display:1 UNCLAIMED description: Display controller product: Mobile 4 Series Chipset Integrated Graphics Controller vendor: Intel Corporation physical id: 2.1 bus info: pci@0000:00:02.1 version: 07 width: 64 bits clock: 33MHz capabilities: pm bus_master cap_list configuration: latency=0 resources: memory:ffc00000-ffcfffff "System Info" shows my graphics as the following Mobile Intel® GM45 Express Chipset x86/MMX/SSE2

    Read the article

  • The physical working paradigm of a signal passing on wire.

    - by smwikipedia
    Hi, This may be more a question of physics, so pardon me if there's any inconvenience. When I study computer networks, I often read something like this in order to represent a signal, we place some voltage on one end of the wire and the other end will detect the voltage and thus the signal. So I am wondering how a signal exactly passes through wire? Here's my current understanding based on my formal knowledge about electronics: First we need a close circuit to constrain/hold the electronic field. When we place a voltage at somewhere A of the circuit, electronic field will start to build up within the circuit medium, this process should be as fast as light speed. And as the electronic field is being built up, the electrons within the circuit medium are moved, and thus electronic current occurs, and once the electronic current is strong enough to be detected at somewhere else B on the complete circuit, then B knows about what has happend at A and thus communication between A and B is achieved. The above is only talking about the process of sending a single voltage through wire. If there's a bitstream and we need to send a series of voltages, I am not sure which of the following is true: The 2nd voltage should only be sent from A after the 1st voltage has been detected at B, the time interval is time needed to stimulate the electronic field in the medium and form a detectable electronic current at B. Several different voltages could be sent on wire one by one, different electronic current values will exists along the wire simutaneously and arrive at B successively. I hope I made myself clear and someone else has ever pondered this question. (I tag this question with network cause I don't know if there's a better option.) Thanks, Sam

    Read the article

  • No video signal after install

    - by tW4r
    Today I tried to install Ubuntu 12.10 to my machine, but all the time I encountered the same problem, I successfully boot from Ubuntu 12.04 DVD, and a purple background comes up with accessibility and keyboard icons at the bottom of the screen, then when you wait a while a monitor text comes up "No signal" (Keep in mind that this signal is only shown when there's cable in the monitor HDMI plug), and nothing happens, a little later disk drive stops flashing meaning that disk finished being read. Even if you reset the computer you still get no signal, you have to turn the power of and on again, and plug HDMI out and put it in again. My info: Graphics card: ATI/AMD Radeon HD 4850 Connection to monitor: HDMI Monitor: Samsung SyncMaster T220HD

    Read the article

  • Is ThinkPad X61T SD card slot SDXC compatible?

    - by trismarck
    I have a Thinkpad X61T 7763 tablet and I was planning to buy a 64GB card for the SD card slot. The 64GB card supports the new SDXC standard and I'm not sure if the SD card driver / hardware can handle that. So far, I've successfully used 8GB cards in the slot, but they were SDHC ones. Thinkpad manuals don't give the answer. I wonder if anyone tried this configuration already and what was the outcome.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • ubuntu server 12.10 get input signal out of range on HP DL380 G4

    - by lix
    After installed ubuntu 12.10 server on HP DL380 G4, I can't boot into it. And the LCD got message "Input signal out of range, recommened settings is 1280x1024". I can't see the terminal and tried several LCDs and still can not work either. How can I should do now? I tried 12.04 but got fail message when installing (select and install software). Is that signal push me to change another os instead of my favorite ubuntu?

    Read the article

  • half-sine pulse shaping

    - by kos
    hi, i wanted to know what is the pulse shape of the modem.oqpskmod? and if it is not half-sine pulse shape, how is it possible to make it half-sine pulse shape as it is stated in ieee 802.15.4(zigbee) standard where it shows it as follows p(t)=sin(pi*t/2*Tc) if 0<=t<=2Tc p(t)=0 if otherwise ? thanks a lot!

    Read the article

  • Generating data on unlevel background

    - by bluejay93
    I want to make an unlevel background and then generate some test data on that using Matlab. I was not clear when I asked this question earlier. So for this simple example for i = 1:10 for j = 1:10 f(i,j)=X.^2 + Y.^2 end end where X and Y have been already defined, it plots it on a flat surface. I don't want to distort the function itself, but I want the surface that it goes onto to be unlevel, changed by some degree or something. I hope that's a little clearer.

    Read the article

  • Execute Slot in different class

    - by sijith
    Hi, I want to execute a slot in different class. Is it possible UI_CDSK Obj; connect(Obj.penDrive,SIGNAL(clicked()),this,SLOT( Obj.caller())); This code is in different class and from this class i want to execute slot of different class(UI_CDSK ) Here penDrive and caller belongs to function UI_CDSK class and the mentioned code is in other class

    Read the article

  • Safe Cross Thread Signals/Slot C++

    - by JP
    It seem that the only implementation that provide Safe Cross-Thread Signals for both the Signal class and what's being called in the slot is QT. (Maybe I'm wrong?). But I cannot use QT in the project I'm doing. So how could I provide safe Slots call from a different thread (Using Boost::signals2 for example)? Are mutex inside the slot the only way? I think signals2 protect themself but not what's being done inside the slot. Thanks

    Read the article

  • slot booking problem

    - by pradeep
    Hi, I am making a doctor appointment slot booking mechanism,where in doctor appointment slots will be divided into 30 mins slot each...i have achieved all the working code.. 1 problem i am facing is that..this booking is made at 2 places i.e 2 receptions..so when 1 selects a slot(radio button) not yet confirmed and saved in DB.other reception must not be able to select .how do i do it.any help on this...how do i go abt it.

    Read the article

  • Wireless signal changes from strong to weak after connecting

    - by gibberish
    Router (primary AP) is a WRVS4400N, WAP (signal booster) is a WAP4410N. Problem: User is physically located within ten feet of WAP (200 feet from main wireless router). Signal is at 5 bars as user connects to wireless network. Within seconds, signal is at or below two bars and connection is poor. Background: Trying to solve problem of weak wireless signal in back offices. Desired result is for client laptops to automatically switch to the stronger signal. WAP is connected to network via Ethernet cable. WAP is set to AP mode (instead of Wireless Repeater mode) WAP does appear to boost signal. Using Windows 7 sys tray Connect To A Network applet, can observe signal boost as laptop approaches the WAP. Above-described problem happens to users located near or beyond the WAP. It does not happen to users in close proximity to the router. Secondary Question: If using WAP in AP Mode, do WAP and Router (primary AP) need to be on the same channel?

    Read the article

  • QObject::connect not connecting signal to slot

    - by user1662800
    I am using C++ and Qt in my project and my problem is QObject::connect function doesn't connect signal to a slot. I have the following classes: class AddCommentDialog : public QDialog { Q_OBJECT public: ...some functions signals: void snippetAdded(); private slots: void on_buttonEkle_clicked(); private: Ui::AddCommentDialog *ui; QString snippet; }; A part of my Main window: class MainWindow : public QMainWindow { Q_OBJECT public: explicit MainWindow(QWidget *parent = 0); ~MainWindow(); private slots: void commentAddedSlot(); void variableAddedSlot(); ... private: AddCommentDialog *addCommentDialog; ... }; Ant the last dialog; class AddDegiskenDialog : public QDialog { Q_OBJECT public: ... signals: void variableAdded(); private slots: void on_buttonEkle_clicked(); private: Ui::AddDegiskenDialog *ui; ... }; In the main window constructor i connect signals and slots: addCommentDialog=new AddCommentDialog(); addDegiskenDialog=new AddDegiskenDialog(); connect(addDegiskenDialog, SIGNAL(variableAdded()), this, SLOT(variableAddedSlot())); connect(addCommentDialog, SIGNAL(snippetAdded()), this, SLOT(commentAddedSlot())); The point is my commentAddedSlot is connected to it's signal successfully, but commentAddedSlot is failed. There is the Q_OBJECT macros, no warning such as about no x slot. In addition to this, receivers(SIGNAL(snippetAdded())) gives me 1 but receivers(SIGNAL(variableAdded())) gives me 0 and i used commands qmake -project; qmake and make to fully compile. What am i missing?

    Read the article

  • The Truth About Wi-Fi Signal Strength

    - by Jason Fitzpatrick
    Whether it’s the structural layout of your home or just ghosts in the machine, we’re all familiar with inexplicable Wi-Fi dead spots. One extra puzzling situation, unseen in the comic here, is when the addition of another wireless node actually causes issues with your Wi-Fi connectivity. There’s nothing more frustrating than having twice the Wi-Fi node power and half the actual signal at your laptop. If you’re looking to extend your Wi-Fi network coverage headache free, check out our guides to doing so with Tomato-powered routers and DD-WRT-powered routers. Your Wireless Internet Signal Strength [via FailDesk] How to Factory Reset Your Android Phone or Tablet When It Won’t Boot Our Geek Trivia App for Windows 8 is Now Available Everywhere How To Boot Your Android Phone or Tablet Into Safe Mode

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >